SY10E337_06 [MICREL]
3-BIT SCANNABLE REGISTERED BUS TRANSCEIVER; 3位可扫描户籍总线收发器型号: | SY10E337_06 |
厂家: | MICREL SEMICONDUCTOR |
描述: | 3-BIT SCANNABLE REGISTERED BUS TRANSCEIVER |
文件: | 总5页 (文件大小:67K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
7
3-BIT SCANNABLE
REGISTERED BUS
TRANSCEIVER
7
SY10E337
SY100E337
FEATURES
DESCRIPTION
■ 1500ps max. clock to bus (data transmit)
■ 1000ps max. clock to Q (data receive)
■ Extended 100E VEE range of –4.2V to –5.5V
■ 25Ω cutoff bus outputs
The SY10/100E337 are 3-bit registered bus transceivers
with scan designed for use in new, high- performance ECL
systems. The bus outputs (BUS0–BUS2) are designed to
drive a 25Ω bus; the receive outputs (Q0–Q2) are designed
for 50Ω. The bus outputs feature a normal logic HIGH level
(VOH) and a cutoff LOW level of –2.0V and the output
emitter-follower is “off”, presenting a high impedance to the
bus. The bus outputs also feature edge slow-down
capacitors.
Both drive and receive sides feature the same logic,
including a loopback path to hold data. The LOAD/HOLD
functioniscontrolledbyTransmitEnable(TEN)andReceive
Enable (REN) on the transmit and receive sides,
respectively, with a HIGH selecting LOAD. The
implementation of the E337 Receive Enable differs from
that of the E336.
■ 50Ω receiver outputs
■ Scannable implementation of E336
■ Synchronous and asynchronous bus enables
■ Non-inverting data path
■ Bus outputs feature internal edge slow-down
capacitors
■ Additional package ground pins
■ Fully compatible with industry standard 10KH,
100K ECL levels
■ Internal 75KΩ input pulldown resistors
■ Fully compatible with Motorola MC10E/100E337
■ Available in 28-pin PLCC package
A synchronous bus enable (SBUSEN) is provided for
normal, non-scan operation. The asynchronous bus disable
(ABUSDIS) disables the bus for scan mode.
The SYNCEN input allows either synchronous or
asynchronous re-enabling after disabling with ABUSDIS.
An alternative use is asynchronous-only operation with
ABUSDIS, in which case SYNCEN is tied LOW. SYNCEN
is implemented as an overriding SET control to the enable
flip-flop.
Scan mode is selected by a logic HIGH at the SCAN
input. Scan input data is shifted in through S-IN, and output
data appears at the Q2 output.
All registers are clocked on the rising edge of CLK.
Additional lead-frame grounding is provided through the
ground pins (GND) which should be connected to 0V. The
GND pins are not electrically connected to the chip.
PIN NAMES
Pin
Function
Data Inputs A
A0–A2
B0–B2
Data Inputs B
S-IN
Serial (Scan) Data Input
LOAD/HOLD Controls
Scan Control
TEN, REN
SCAN
ABUSDIS
SBUSEN
SYNCEN
CLK
Asynchronous Bus Disable
Synchronous Bus Enable
Synchronous Enable Control
Clock
BUS0–BUS2
Q0–Q2
25Ω Cutoff BUS Outputs
Receive Data Outputs (Q2 serves as
SCAN_OUT in scan mode)
VCCO
VCC to Output
Rev.: F
Amendment: /0
M9999-032206
hbwhelp@micrel.com or (408) 955-1690
1
Issue Date: March 2006
SY10E337
SY100E337
Micrel, Inc.
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
Package Operating
Package
Marking
Lead
Finish
Part Number
Type
J28-1
J28-1
J28-1
Range
SY10E337JC
Commercial
Commercial
Commercial
SY10E337JC
SY10E337JC
SY100E337JC
Sn-Pb
Sn-Pb
Sn-Pb
25 24 23 22 21 20 19
SY10E337JCTR(2)
SCAN
S-IN
26
27
28
1
18
17
16
15
14
13
12
GND
BUS
0
SY100E337JC
TEN
V
CC
TOP VIEW
PLCC
SY100E337JCTR(2)
SY10E337JZ(3)
J28-1
J28-1
Commercial
Commercial
SY100E337JC
Sn-Pb
V
EE
Q
1
J28-1
REN
CLK
2
V
CCO
SY10E337JZ with
Matte-Sn
3
BUS
1
Pb-Free bar-line indicator
A
1
4
GND
SY10E337JZTR(2, 3)
SY100E337JZ(3)
J28-1
J28-1
Commercial
Commercial
SY10E337JZ with
Pb-Free bar-line indicator
Matte-Sn
Matte-Sn
5
6
7
8
9
10 11
SY100E337JZ with
Pb-Free bar-line indicator
SY100E337JZTR(2, 3)
J28-1
Commercial
SY100E337JZ with
Matte-Sn
28-Pin PLCC (J28-1)
Pb-Free bar-line indicator
Notes:
1. Contact factory for die availability. Dice are guaranteed at T = 25°C, DC Electricals only.
A
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032206
hbwhelp@micrel.com or (408) 955-1690
2
SY10E337
SY100E337
Micrel, Inc.
BLOCK DIAGRAM
BUS
2
Q
2
D
D
D
D
D
D
Q
Q
Q
Q
Q
Q
SCAN-OUT
A2
B2
BUS
1
Q1
A1
B1
BUS
0
Q0
A0
B0
S-IN
TEN
REN
SCAN
ABUSDIS
SBUSEN
D
Q
SET
SYNCEN
CLK
M9999-032206
hbwhelp@micrel.com or (408) 955-1690
3
SY10E337
SY100E337
Micrel, Inc.
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
Condition
VCUT
IIH
Cut-off Output Voltage
–2.10
—
—
–2.03 –2.10
—
—
–2.03 –2.10
—
—
–2.03
V
1
Input HIGH Current
All Other Inputs
—
150
—
150
—
150
µA
—
IEE
Power Supply Current
mA
—
10E
100E
—
—
145 174
145 174
—
—
145 174
125 174
—
—
145
167
174
200
Note:
1. Applies to BUS outputs only. Measured with VTT = –2.10V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
Condition
tPD
Propagation Delay to Output
CLK to Q
CLK to BUS
ABUSDIS
SYNCEN
ps
—
450
800
500
800
—
—
—
—
1000 450
1800 800
1500 500
1800 800
—
—
—
—
1000 450
1800 800
1500 500
1800 800
—
—
—
—
1000
1800
1500
1800
tS
Set-up Time
BUS
SBUSEN
Data, S-IN
TEN, REN, SCAN
ps
ps
—
—
350
100
400
550
—
—
—
—
—
—
—
—
350
100
400
550
—
—
—
—
—
—
—
—
350
100
400
550
—
—
—
—
—
—
—
—
tH
Hold Time
BUS
SBUSEN
Data, S-IN
TEN, REN, SCAN
350
500
350
200
—
—
—
—
—
—
—
—
350
500
350
200
—
—
—
—
—
—
—
—
350
500
350
200
—
—
—
—
—
—
—
—
tPW
Minimum Pulse Width
400
—
—
400
—
—
400
—
—
ps
ps
—
—
tr
tf
Rise/Fall Time
20% to 80% (Qn)
20% to 80% (BUSn Rise)
20% to 80% (BUSn Fall)
300
500
300
—
—
—
800 300
1000 500
800 300
—
—
—
800
1000 500
800 300
300
—
—
—
800
1000
800
M9999-032206
hbwhelp@micrel.com or (408) 955-1690
4
SY10E337
SY100E337
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032206
hbwhelp@micrel.com or (408) 955-1690
5
相关型号:
©2020 ICPDF网 联系我们和版权申明