LV25-200 [LEM]
Voltage Transducer LV 25-200; 电压互感器低压25-200型号: | LV25-200 |
厂家: | LEM |
描述: | Voltage Transducer LV 25-200 |
文件: | 总2页 (文件大小:82K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Voltage Transducer LV 25-200
VPN = 200 V
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Electrical data
VPN
VP
IPN
Primary nominal r.m.s. voltage
Primary voltage, measuring range
Primary nominal r.m.s. current
Measuring resistance
200
0 .. ± 300
10
V
V
mA
Features
· Closed loop (compensated) voltage
transducer using the Hall effect
· Transducer with insulated plastic
case recognized according to
UL 94-V0
· Primary resistor R 1 and transducer
mounted on printed circuit board
128 x 60 mm.
RM
RM min
RMmax
with ± 12 V
@ ± 200 V max
30
30
100
100
200
100
320
180
W
W
W
W
@ ± 300 V max
@ ± 200 V max
@ ± 300 V max
with ± 15 V
ISN
KN
VC
IC
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test 1), 50 Hz, 1 mn
25
mA
200 V / 25 mA
± 12 .. 15
10 (@±15V)+IS mA
V
Advantages
Vd
4.1
kV
· Excellent accuracy
· Very good linearity
· Low thermal drift
· High immunity to external
interference.
Accuracy - Dynamic performance data
XG
Overall Accuracy @ VPN , TA = 25°C
Linearity
± 0.8
< 0.2
%
%
e
L
Applications
Typ
Max
± 0.15 mA
IO
IOT
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
· AC variable speed drives and servo
motor drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
- 25°C .. + 25°C
+ 25°C .. + 70°C
± 0.10 ± 0.60 mA
± 0.10 ± 0.60 mA
tr
Response time @ 90 % of VP max
15
µs
General data
· Power supplies for welding
applications.
TA
TS
N
Ambient operating temperature
Ambient storage temperature
Turns ratio
Total primary power loss
Primary resistance @ TA = 25°C
- 25 .. + 70
- 40 .. + 85
2500 : 1000
2
20
110
°C
°C
P
W
kW
W
R1
RS
m
Secondary coil resistance @ TA = 70°C
Mass
Standards
60
g
2)
EN 50178
1)
Notes : Between primary and secondary
2)
A list of corresponding tests is available
980909/2
LEM Components
www.lem.com
Dimensions LV 25-200 (in mm. 1 mm = 0.0394 inch)
Front view
Top view
Standard 00
or N° SP..
Year Week
Secondary terminals
Connection
Terminal + : supply voltage + 12 .. 15 V
Terminal M : measure
Terminal
- : supply voltage - 12 .. 15 V
Mechanical characteristics
Remarks
· General tolerance
· Fastening
· Connection of primary
· Connection of secondary
± 0.3 mm
· IS is positive when VP is applied on terminal +HT.
· The primary circuit of the transducer must be linked to the
connections where the voltage has to be measured.
· This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
4 holes Æ 4.2 mm
Faston 6.3 x 0.8 mm
Faston 6.3 x 0.8 mm
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
相关型号:
LV250M1200BP343045
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 1200uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LV250M180BP442030
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 180uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LV250M180BP442225
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 180uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LV250M220BP4-2230
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 220uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
©2020 ICPDF网 联系我们和版权申明