LV25-P [LEM]

VOLTAGE TRANSDUCER LV 25-P; 电压传感器LV 25 -P
LV25-P
型号: LV25-P
厂家: LEM    LEM
描述:

VOLTAGE TRANSDUCER LV 25-P
电压传感器LV 25 -P

传感器 换能器
文件: 总2页 (文件大小:54K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Voltage Transducer LV 25-P  
IPN = 10 mA  
For the electronic measurement of voltages : DC, AC, pulsed...,  
with a galvanic isolation between the primary circuit (high voltage)  
and the secondary circuit (electronic circuit).  
VPN = 10 .. 500 V  
Electrical data  
I PN  
IP  
RM  
Primary nominal r.m.s. current  
Primary current, measuring range  
Measuring resistance  
10  
0 .. ± 14  
RM min  
mA  
mA  
Features  
RM max  
· Closed loop (compensated) voltage  
transducer using the Hall effect  
· Insulated plastic case recognized  
according to UL 94-V0.  
with ± 12 V  
@ ± 10 mA max  
30  
30  
100  
100  
190  
100  
350  
190  
W
W
W
W
@ ± 14 mA max  
@ ± 10 mA max  
@ ± 14 mA max  
with ± 15 V  
Principle of use  
ISN  
KN  
VC  
IC  
Secondary nominal r.m.s. current  
Conversion ratio  
Supply voltage (± 5 %)  
Current consumption  
R.m.s. voltage for AC isolation test 1), 50 Hz, 1 mn  
25  
mA  
2500 : 1000  
± 12 .. 15  
10 (@± 15 V)+ IS mA  
· For voltage measurements, a current  
proportional to the measured voltage  
must be passed through an external  
resistor R 1 which is selected by the  
user and installed in series with the  
primary circuit of the transducer.  
V
Vd  
2.5  
kV  
Accuracy - Dynamic performance data  
XG  
Overall Accuracy @ IPN , TA = 25°C @ ± 12 .. 15 V  
± 0.9  
± 0.8  
< 0.2  
%
%
%
Advantages  
@ ± 15 V (± 5 %)  
e
Linearity  
· Excellent accuracy  
· Very good linearity  
· Low thermal drift  
· Low response time  
· High bandwidth  
L
Typ  
Max  
± 0.15 mA  
IO  
IOT  
Offset current @ IP = 0, TA = 25°C  
Thermal drift of IO  
0°C .. + 25°C  
± 0.06 ± 0.25 mA  
± 0.10 ± 0.35 mA  
+ 25°C .. + 70°C  
· High immunity to external  
interference  
tr  
Response time 2) @ 90 % of VP max  
40  
µs  
· Low disturbance in common mode.  
General data  
Applications  
TA  
TS  
RP  
RS  
m
Ambient operating temperature  
Ambient storage temperature  
0 .. + 70  
- 25 .. + 85  
250  
110  
22  
°C  
°C  
W
W
g
· AC variable speed drives and servo  
motor drives  
· Static converters for DC motor drives  
· Battery supplied applications  
· Uninterruptible Power Supplies  
(UPS)  
Primary coil resistance @ TA = 70°C  
Secondary coil resistance @ TA = 70°C  
Mass  
3)  
Standards  
EN 50178  
· Power supplies for welding  
applications.  
1)  
Notes : Between primary and secondary  
2)  
R 1 = 25 kW (L/R constant, produced by the resistance and inductance  
of the primary circuit)  
A list of corresponding tests is available  
3)  
981125/14  
LEM Components  
Tope Co., Ltd. Tel: (02) 8228-0658  
www.lem.com  
Fax: (02) 8228-0659  
http://www.sensor.com.tw  
e-mail: tope@ms1.hinet.net  
Dimensions LV 25-P (in mm. 1 mm = 0.0394 inch)  
Bottom view  
Right view  
Top view  
swiss  
made  
Standard 00  
or N° SP..  
Year Week  
Secondary terminals  
Terminal + : supply voltage + 12 .. 15 V  
Terminal M : measure  
Terminal  
- : supply voltage - 12 .. 15 V  
Connection  
Back view  
Mechanical characteristics  
Remarks  
· General tolerance  
· Fastening & connection of primary  
± 0.2 mm  
2 pins  
0.635 x 0.635 mm  
· IS is positive when VP is applied on terminal +HT.  
· This is a standard model. For different versions (supply  
voltages, turns ratios, unidirectional measurements...),  
please contact us.  
· Fastening & connection of secondary 3 pins Æ 1 mm  
· Recommended PCB hole 1.2 mm  
Instructions for use of the voltage transducer model LV 25-P  
Primary resistor R 1 : the transducer’s optimum accuracy is obtained at the nominal primary current. As far as possible, R 1 should be  
calculated so that the nominal voltage to be measured corresponds to a primary current of 10 mA.  
Example: Voltage to be measured VPN = 250 V  
a) R1 = 25 kW/2.5 W, IP = 10 mA  
b) R1 = 50 kW/1.25 W, IP = 5 mA  
Accuracy = ± 0.8 % of VPN (@ TA = + 25°C)  
Accuracy = ± 1.6 % of VPN (@ TA = + 25°C)  
Operating range (recommended) : taking into account the resistance of the primary windings (which must remain low compared to R 1, in order  
to keep thermal deviation as low as possible) and the isolation, this transducer is suitable for measuring nominal voltages from 10 to 500 V.  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.  

相关型号:

LV2501

VHF HYPERABRUPT TUNING DIODES
KNOX

LV2501A

VHF HYPERABRUPT TUNING DIODES
KNOX

LV2502

VHF HYPERABRUPT TUNING DIODES
KNOX

LV2502A

VHF HYPERABRUPT TUNING DIODES
KNOX

LV250M1200BP343045

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 1200uF, Through Hole Mount, ROHS COMPLIANT
YAGEO

LV250M180BP442030

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 180uF, Through Hole Mount, ROHS COMPLIANT
YAGEO

LV250M180BP442225

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 180uF, Through Hole Mount, ROHS COMPLIANT
YAGEO

LV250M220BP4-2230

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 220uF, Through Hole Mount, ROHS COMPLIANT
YAGEO

LV250M220BP442230

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 220uF, Through Hole Mount, ROHS COMPLIANT
YAGEO

LV250M220BPF-2035

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 220uF, Through Hole Mount, ROHS COMPLIANT
YAGEO

LV250M220BPF42035

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 220uF, Through Hole Mount, ROHS COMPLIANT
YAGEO

LV250M330BP342530

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 250V, 20% +Tol, 20% -Tol, 330uF, Through Hole Mount, ROHS COMPLIANT
YAGEO