M9005A-002 [KEYSIGHT]

Integrated System Module, 5-slots, 3U;
M9005A-002
型号: M9005A-002
厂家: Keysight Technologies    Keysight Technologies
描述:

Integrated System Module, 5-slots, 3U

文件: 总9页 (文件大小:1426K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Keysight Technologies  
M9005A PXIe Chassis  
Integrated System Module, 5-slots, 3U  
Data Sheet  
Introduction  
The Keysight Technologies, Inc. M9005A PXIe 5-slot chassis is the smallest footprint family  
member of Keysight’s PXIe chassis product line. It has been designed as a low cost, bench  
friendly solution while still enabling PXIe compatibility and performance. The integrated  
system module enables a solution that is fast and easy to setup. The combination of footprint,  
cost, and performance make it a perfect entry-level chassis for many applications.  
Key Features  
– Small footprint, bench friendly, 4U PXIe chassis  
– 5 peripheral slots: 3 PXIe hybrid slots, 2 PXIe-only slots  
– Integrated PXIe Gen1 x1 system module for use with desktop host adapter  
– Up to 250 MB/s total system bandwidth  
– Up to 250 MB/s per-slot data bandwidth  
– Specified up to 50 °C and 2000 m operating conditions  
03 | Keysight | M9005A PXIe Chassis - Data Sheet  
Hardware Overview  
Backplane configuration  
The M9005 PXIe chassis provides 5 peripheral slots: 3 hybrid-compatible slots and 2 PXI  
Express for a combination of measurement flexibility and performance. Each slot has  
a PCIe® x1 Gen 1 link to the upstream PC. Each hybrid peripheral slot can accept a PXI  
Express peripheral module, a CompactPCI Express Type-2 peripheral, or a PXI-1 module  
which has the J2 connector replaced with the XJ4 connector. The hybrid slots provide  
full PXI Express and 32-bit PXI functionality.  
Figure 1. Backplane configuration diagram of the M9005A PXIe 5-slot chassis.  
04 | Keysight | M9005A PXIe Chassis - Data Sheet  
Software Overview  
The M9005A provides a simple use model. The only necessary software is low level  
chassis driver which allows the system PXI resource manager to enumerate the M9005A  
chassis and the installed modules.  
Keysight Standard Warranty  
With Keysight’s standard warranty, your investment is protected by Keysight’s global  
reach in more than 100 countries (either directly or through distributors). The warranty  
gives you convenient standard coverage for the country in which the product is used,  
eliminating the need to ship equipment back to the country of purchase. Keysight’s  
warranty service provides:  
– All parts and labor necessary to return your investment to full specified  
performance  
– Recalibration for products supplied originally with a calibration certificate  
– Return shipment  
Definitions  
Specifications  
Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties,  
and changes in performance due to environmental conditions. All specifications and characteristics apply over the operating environment outlined in the  
“Environmental and Regulatory” section of this data sheet. In addition, the following conditions must be met:  
Instrument is within its calibration cycle if calibration is required.  
Instrument has been stored for a minimum of 1 hour within the operating temperature range prior to turn-on and after a 30 minute warm-up period.  
Characteristic  
Characteristics describe product performance that is useful in the application of the product, but that is not covered by the product warranty.  
Characteristics are often referred to as Typical or Nominal values.  
Typical  
Expected performance of an average unit when operated over a 20 to 30 °C temperature range. Typical performance is not warranted. The instrument  
must be within its calibration cycle if calibration is required.  
Nominal  
Nominal describes representative performance that is useful in the application of the product when operated over a 20 to 30 °C temperature range.  
Nominal performance is not warranted.  
Module specifications and configuration  
Some module specifications may be affected by chassis characteristics. Refer to module datasheet to determine the configuration used when  
specifications were set and to ensure module power and cooling requirements are met.  
Additional information  
All data are measured from multiple units at room temperature and are representative of product performance within the operating temperature range  
unless otherwise noted.  
The specifications contained in this document are subject to change.  
05 | Keysight | M9005A PXIe Chassis - Data Sheet  
Technical Characteristics  
Chassis characteristics  
Standards compliance  
PXI-5 PXI Express hardware specification  
PXI-1 hardware specification rev 2.2  
PICMG® EXP.0 R1.0 specification  
Backplane characteristics  
Module size  
3U  
Total number of slots  
5
Hybrid compatible slots  
PXIe only slots  
3
2
System slot  
Integrated system module. PCIe Revision 1 x1 connection to external controller  
Feature not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required  
PXIe, PXI-hybrid, PXI-1 (J1-only), and cPCI (J1-only)  
PCIe Revision 1.0 (Gen 1). x1 to each instrument slot  
PXIe timing slot  
Module compatibility (depending on slot)  
Backplane speed  
Mechanical characteristics  
Size  
257.1 mm W x 189.7 mm H x 212.8 mm D (with feet installed)  
257.1 mm W x 177 mm H x 212.8 mm D (with feet removed)  
6U x 1 rack width  
Weight (without modules)  
Power supply  
5 kg (11.0 lbs)  
AC input  
Input voltage range  
Input frequency range  
Input current rating  
Over current protection  
Available DC output power (for module slots)  
Total DC power  
100-240 VAC, nominal  
50/60 Hz  
4-2 A  
All outputs protected from short circuit  
Maximum total power  
Per slot power, for each of 5 slots  
DC supplies  
150 W  
30 W  
Voltage  
Maximum current  
+3.3 V  
15 A  
+5 V  
7.5 A  
15 A  
+12 V  
-12 V  
0.75 A  
1.0 A  
5 VAUX  
Over-voltage protection  
Active range  
Over-voltage at  
Minimum  
3.76 V  
Maximum  
4.3 V  
+3.3 V  
+5 V  
5.75 V  
7.0 V  
+12 V  
13.4 V  
15.6 V  
Backplane pin current capacity  
Slot  
+3.3 V  
+5 V  
0 A  
+ 12 V  
-12 V  
0 A  
PXIe slot  
Hybrid slot  
6 A  
6 A  
4 A  
4 A  
6 A  
1 A  
06 | Keysight | M9005A PXIe Chassis - Data Sheet  
Technical Characteristics, continued  
Chassis cooling and power dissipation  
Slot airflow direction  
Bottom of module to top of module  
Chassis cooling intake  
Bottom of chassis  
Chassis cooling exhaust  
Chassis cooling fan  
Along rear, right side, and top of chassis  
One 126 cfm fan on bottom of chassis with High/Auto speed selector  
38 W  
Power dissipation, peripheral slot  
Power supply cooling  
Forced air circulation through integrated fan  
Front side of chassis  
Power supply cooling intake  
Power supply cooling exhaust  
Rear side of chassis  
When placed into an instrument rack or on a bench, maximum per slot power dissipation requires that the chassis bottom and top is not blocked. In an  
instrument rack, provide 1U rack space below and above the chassis. On the bench, the instrument feet provide the necessary bottom clearance. Slot  
blockers and EMC filler panels are recommended to be used in empty slots. Module cooling is affected by the module’s resistance to air flow.  
Clocks and triggers  
10 MHz system clock (PXI_CLK10)  
Maximum slot-to-slot skew  
Accuracy  
250 ps  
±25 ppm max. (guaranteed over the operating temperature range)  
Duty factor  
45%-55%  
Unloaded signal swing  
3.3 V ±0.3 V  
External 10 MHz clock output feature is not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required  
100 MHz system clock (PXIe_CLK100)  
Maximum slot-to-slot skew  
Accuracy  
100 ps  
±25 ppm max. (guaranteed over the operating temperature range)  
Duty factor  
45% - 55%  
Absolute single-ended voltage swing  
400 to 1000 mV  
(when each line in the differential pair has 50 Ω  
termination to 1.30 V or Thevenin equivalent)  
External 10 MHz clock source input requirements  
Feature not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required for synchronization.  
PXI star trigger  
Feature not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required for synchronization.  
PXI differential star triggers  
Feature not available in M9005A. Consider M9010A, M9018B, M9019A chassis if required for synchronization.  
Host adapter characteristics  
Card format  
Low profile  
PCI bracket  
Includes low and standard profile  
6.7 cm x 7.1 cm (2.6 in x 2.8 in)  
PCIe x1, x8, or x16  
Dimensions  
Computer slot compatibility  
Maximum cable length  
Sustained data throughput  
Power consumption  
3 m  
Up to 215 MB/s  
1.2 W (typ), 360 mA @ 3.3 V  
07 | Keysight | M9005A PXIe Chassis - Data Sheet  
Technical Characteristics, continued  
Environmental characteristics 1, 2  
Operating  
Storage  
Temperature  
0 to 50 ˚C  
–40 to 70 ˚C  
Altitude  
Up to 6,562 ft (2,000m) at 25 °C ambient  
Type-tested 20 to 80%, non-condensing  
Humidity  
Type-tested 10 to 95%, non-condensing  
Vibration  
Operating random vibration  
Survival random vibration  
Acoustical emissions (referenced to 1pW)  
Sound pressure level 3  
Sound power  
5 to 500 Hz, 0.3 g rms  
5 to 500 Hz, 2.4 g rms  
Auto fan (25°C ambient)  
43 dBA  
High fan  
58 dBA  
65 dBA  
51 dBA  
1. Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environ-  
mental stresses of storage, transportation and end-use. Those stresses include but are not limited to temperature, humidity, shock, vibration, altitude and  
power line conditions.  
2. Test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3  
3. At operator position  
Regulatory characteristics  
Safety  
Complies with the essential requirements of the European LVD Directive as well as current editions of the following standards (dates and editions are  
cited in the Declaration of Conformity):  
IEC/EN 61010-1  
Canada: CSA C22.2 No. 61010-1  
USA: UL std no. 61010-1  
Acoustic statement (European Machinery Directive)  
Acoustic noise emmission  
LpA <70 dB  
Operator position  
Normal position Per ISO 7779  
EMC  
Complies with the essential requirements of the following applicable European Directives, and carries the CE marking accordingly:  
Complies with European EMC Directive 2014/30/EU of the following standards (dates and editions are cited in the Declaration of Conformity):  
IEC/EN 61326-1 Basic Immunity  
CISPR pub 11 group 1, class A  
AS/NZS CISPR 11  
ICES/NMB-001  
This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canada  
08 | Keysight | M9005A PXIe Chassis - Data Sheet  
Recommended Configuration  
Hardware  
Configure the Keysight M9005A PXIe chassis as follows:  
– Add the PC interface card  
– The host adapter comes preconfigured with a 3 m PCIe  
cable.  
Model  
Description  
M9005A  
M9005A-002  
Includes  
5-slot, PXIe chassis with integrated system module  
PCIe Desktop adapter for M9005A + 3m cable  
Standard PXI filler panels, getting started guide,  
drivers, and Keysight I/O libraries  
– Use slot blockers and EMC filler panels in empty module slots  
to ensure proper module operating temperatures.  
– Chassis fan may need to be set at high in order to provide  
required module cooling at targeted environment cooling.  
– Module cooling can be impacted by each module’s resistance  
to air flow, therefore, refer to each module data sheet for  
information regarding power and cooling to ensure proper  
configurations.  
– Place modules which have high cooling requirements in the  
center slots of the M9005A. For high power modules, contact  
your local Keysight office regarding compatibility of the  
M9005A with your desired modular configuration.  
Accessories  
Model  
Description  
Y1212A  
Y1213A  
Y1274A  
Slot blocker kit: 5 single-slot  
PXI EMC filler panel kit: 5 single-slot filler panels  
Rack mount kit  
Services  
Advantage Services: Calibration  
Keysight Advantage Services is committed to your success throughout  
your equipment’s lifetime.  
Software information  
Supported  
Microsoft Windows 7 SP1 (32/64-bit)  
operating systems Microsoft Windows 8.1 Update 1 (32/64-bit)  
Microsoft Windows 10 (32/64-bit)  
Standard  
No IVI drivers required for this chassis  
compliant drivers  
Supported  
application  
development  
environments  
(ADE)  
LabVIEW, LabWindows/CVI, MATLAB, VEE, Visual  
Basic, VisualStudio.NET (C/C++, C#, VB.NET)  
Keysight IO  
Libraries  
Supported versions: 17.2 (or later). Use of latest  
version recommended. Includes: VISA Libraries,  
Keysight Connection Expert, IO Monitor  
Figure 2. Y1274A M9005A Rack Mount Kit.  
09 | Keysight | M9005A PXIe Chassis - Data Sheet  
For more information on Keysight  
Evolving Since 1939  
Our unique combination of hardware, software, services, and people can help you  
reach your next breakthrough. We are unlocking the future of technology.  
From Hewlett-Packard to Agilent to Keysight.  
Technologies’ products, applications or  
services, please contact your local Keysight  
office. The complete list is available at:  
www.keysight.com/find/contactus  
Americas  
Canada  
Brazil  
Mexico  
United States  
(877) 894 4414  
55 11 3351 7010  
001 800 254 2440  
(800) 829 4444  
Asia Pacific  
Australia  
China  
Hong Kong  
India  
Japan  
Korea  
Malaysia  
Singapore  
Taiwan  
1 800 629 485  
800 810 0189  
800 938 693  
1 800 11 2626  
0120 (421) 345  
080 769 0800  
1 800 888 848  
1 800 375 8100  
0800 047 866  
(65) 6375 8100  
myKeysight  
www.keysight.com/find/mykeysight  
A personalized view into the information most relevant to you.  
Other AP Countries  
www.keysight.com/find/emt_product_registration  
Register your products to get up-to-date product information and  
find warranty information.  
Europe & Middle East  
Austria  
Belgium  
Finland  
France  
Germany  
Ireland  
Israel  
Italy  
Luxembourg  
Netherlands  
Russia  
0800 001122  
0800 58580  
0800 523252  
0805 980333  
0800 6270999  
1800 832700  
1 809 343051  
800 599100  
+32 800 58580  
0800 0233200  
8800 5009286  
800 000154  
0200 882255  
0800 805353  
Opt. 1 (DE)  
Keysight Services  
www.keysight.com/find/service  
Keysight Services can help from acquisition to renewal across your  
instrument’s lifecycle. Our comprehensive service offerings—one-  
stop calibration, repair, asset management, technology refresh,  
consulting, training and more—helps you improve product quality  
and lower costs.  
Keysight Assurance Plans  
www.keysight.com/find/AssurancePlans  
Up to ten years of protection and no budgetary surprises to ensure  
your instruments are operating to specification, so you can rely on  
accurate measurements.  
Spain  
Sweden  
Switzerland  
Opt. 2 (FR)  
Opt. 3 (IT)  
0800 0260637  
Keysight Channel Partners  
www.keysight.com/find/channelpartners  
United Kingdom  
Get the best of both worlds: Keysight’s measurement expertise and  
product breadth, combined with channel partner convenience.  
For other unlisted countries:  
www.keysight.com/find/contactus  
(BP-9-7-17)  
PCI-SIG®, PCIe® and the PCI Express® are US registered trademarks and/or service marks  
of PCI-SIG.  
PICMG® and the PICMG logo are registered US trademarks of the PCI Industrial Computer  
Manufacturers Group.  
ꢀꢁꢂꢃꢄ Cꢅrtꢆfꢆꢅd  
ꢇSꢈꢉꢊꢊꢋ ꢌꢍaꢎꢆtꢏ ꢐanaꢑꢅmꢅnt Sꢏꢒtꢅm  
www.keysight.com/go/quality  
Keysight Technologies, Inc.  
DEKRA Certified ISO 9001:2015  
Quality Management System  
This information is subject to change without notice.  
© Keysight Technologies, 2017  
Published in USA, December 1, 2017  
5992-1851EN  
www.keysight.com  

相关型号:

M901-01-622.0800LF

Clock Generator, 622.08MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-625.0000

Clock Generator, 625MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-625.0000LF

Clock Generator, 625MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-627.3296LF

Clock Generator, 627.3296MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-644.5313LF

Clock Generator, 644.5313MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-666.5143LF

Clock Generator, 666.5143MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-669.1281LF

Clock Generator, 669.1281MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-669.3120LF

Clock Generator, 669.312MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-669.3266LF

Clock Generator, 669.3266MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-669.6429LF

Clock Generator, 669.6429MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-670.8386LF

Clock Generator, 670.8386MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT

M901-01-672.1600LF

Clock Generator, 672.16MHz, CQCC36, 9 X 9 MM, CERAMIC, LCC-36
IDT