ICs for Communications  
Extended PCM Interface Controller  
EPIC®-1  
PEB 2055 / PEF 2055 Versions A3  
EPIC®-S  
PEB 2054 / PEF 2054 Versions 1.0  
User’s Manual 02.97  
PEB 2055  
PEF 2055  
Revision History:  
User’s Manual 02.97  
Previous Release:  
Technical Manual 02.92 (Editorial Update)  
Subjects (major changes since last revision)  
Page (in  
Previous  
Release)  
Page  
(in User’s  
Manual)  
Edition 02.97  
This edition was realized using the software system FrameMaker .  
Published by Siemens AG,  
Bereich Halbleiter, Marketing-  
Kommunikation, Balanstraße 73,  
81541 München  
© Siemens AG 7/23/97.  
All Rights Reserved.  
Attention please!  
As far as patents or other rights of third parties are concerned, liability is only assumed for components, not for applications, processes  
and circuits implemented within components or assemblies.  
The information describes the type of component and shall not be considered as assured characteristics.  
Terms of delivery and rights to change design reserved.  
For questions on technology, delivery and prices please contact the Semiconductor Group Offices in Germany or the Siemens Companies  
and Representatives worldwide (see address list).  
Due to technical requirements components may contain dangerous substances. For information on the types in question please contact  
your nearest Siemens Office, Semiconductor Group.  
Siemens AG is an approved CECC manufacturer.  
Packing  
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we  
will take packing material back, if it is sorted. You must bear the costs of transport.  
For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs in-  
curred.  
Components used in life-support devices or systems must be expressly authorized for such purpose!  
1
2
Critical components of the Semiconductor Group of Siemens AG, may only be used in life-support devices or systems with the express  
written approval of the Semiconductor Group of Siemens AG.  
1 A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the  
failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.  
2 Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain hu-  
man life. If they fail, it is reasonable to assume that the health of the user may be endangered.  
PEB 2055  
PEF 2055  
Table of Contents  
Page  
1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
Pin Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9  
Pin Definitions and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11  
Logic Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
Functional Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
Using the EPIC-S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17  
System Integration and Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
Digital Line Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
1.1  
1.2  
1.3  
1.4  
1.5  
1.6  
1.7  
1.7.1  
1.7.1.1 Switching, Layer-1 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
1.7.1.2 Decentralized D-Channel Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
1.7.1.3 Central D-Channel Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20  
1.7.1.4 Mixed D-Channel Processing, Signaling Decentralized,  
Packet Data Centralized  
21  
1.7.2  
1.7.3  
Analog Line Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23  
Packet Handlers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
2
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27  
Bus Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27  
PCM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28  
Configurable Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29  
Memory Structure and Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29  
Pre-processed Channels, Layer-1 Support . . . . . . . . . . . . . . . . . . . . . . . . . .31  
Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31  
2.1  
2.2  
2.3  
2.4  
2.5  
2.6  
3
3.1  
3.2  
3.3  
Operational Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32  
Microprocessor Interface Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32  
Clocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
EPIC® Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
PCM-Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35  
Configurable Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36  
Switching Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38  
Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41  
Initialization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
Hardware Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
EPIC® Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
3.4  
3.4.1  
3.4.2  
3.4.3  
3.4.4  
3.5  
3.5.1  
3.5.2  
3.5.2.1 Register Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
3.5.2.2 Control Memory Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42  
3.5.2.3 Initialization of Pre-processed Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . .43  
3.5.2.4 Initialization of the Upstream Data Memory (DM) Tristate Field . . . . . . . . . .45  
3.5.3  
Activation of the PCM and CFI Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . .45  
Semiconductor Group  
3
02.97  
PEB 2055  
PEF 2055  
Table of Contents  
Page  
4
Detailed Register Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46  
Register Address Arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46  
Detailed Register Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48  
PCM Interface Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48  
4.1  
4.2  
4.2.1  
4.2.1.1 PCM-Mode Register (PMOD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48  
4.2.1.2 Bit Number per PCM-Frame (PBNR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50  
4.2.1.3 PCM-Offset Downstream Register (POFD) . . . . . . . . . . . . . . . . . . . . . . . . . .50  
4.2.1.4 PCM-Offset Upstream Register (POFU) . . . . . . . . . . . . . . . . . . . . . . . . . . . .51  
4.2.1.5 PCM-Clock Shift Register (PCSR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51  
4.2.1.6 PCM-Input Comparison Mismatch (PICM) . . . . . . . . . . . . . . . . . . . . . . . . . . .52  
4.2.2  
Configurable Interface Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53  
4.2.2.1 Configurable Interface Mode Register 1 (CMD1) . . . . . . . . . . . . . . . . . . . . . .53  
4.2.2.2 Configurable Interface Mode Register 2 (CMD2) . . . . . . . . . . . . . . . . . . . . . .55  
4.2.2.3 Configurable Interface Bit Number Register (CBNR) . . . . . . . . . . . . . . . . . . .58  
4.2.2.4 Configurable Interface Time Slot Adjustment Register (CTAR) . . . . . . . . . . .58  
4.2.2.5 Configurable Interface Bit Shift Register (CBSR) . . . . . . . . . . . . . . . . . . . . . .59  
4.2.2.6 Configurable Interface Subchannel Register (CSCR) . . . . . . . . . . . . . . . . . .60  
4.2.3  
Memory Access Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61  
4.2.3.1 Memory Access Control Register (MACR) . . . . . . . . . . . . . . . . . . . . . . . . . . .61  
4.2.3.2 Memory Access Address Register (MAAR) . . . . . . . . . . . . . . . . . . . . . . . . . .65  
4.2.3.3 Memory Access Data Register (MADR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66  
4.2.4  
Synchronous Transfer Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67  
4.2.4.1 Synchronous Transfer Data Register (STDA) . . . . . . . . . . . . . . . . . . . . . . . .67  
4.2.4.2 Synchronous Transfer Data Register B (STDB) . . . . . . . . . . . . . . . . . . . . . .67  
4.2.4.3 Synchronous Transfer Receive Address Register A (SARA) . . . . . . . . . . . . .68  
4.2.4.4 Synchronous Transfer Receive Address Register B (SARB) . . . . . . . . . . . . .69  
4.2.4.5 Synchronous Transfer Transmit Address Register A (SAXA) . . . . . . . . . . . .69  
4.2.4.6 Synchronous Transfer Transmit Address Register B (SAXB) . . . . . . . . . . . .70  
4.2.4.7 Synchronous Transfer Control Register (STCR) . . . . . . . . . . . . . . . . . . . . . .70  
4.2.5  
Monitor/Feature Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71  
4.2.5.1 MF-Channel Active Indication Register (MFAIR) . . . . . . . . . . . . . . . . . . . . . .71  
4.2.5.2 MF-Channel Subscriber Address Register (MFSAR) . . . . . . . . . . . . . . . . . . .72  
4.2.5.3 Monitor/Feature Control Channel FIFO (MFFIFO) . . . . . . . . . . . . . . . . . . . . .73  
4.2.6  
Status/Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73  
4.2.6.1 Signaling FIFO (CIFIFO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73  
4.2.6.2 Timer Register (TIMR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74  
4.2.6.3 Status Register (STAR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75  
4.2.6.4 Command Register (CMDR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76  
4.2.6.5 Interrupt Status Register (ISTA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78  
4.2.6.6 Mask Register (MASK) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79  
4.2.6.7 Operation Mode Register (OMDR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80  
Semiconductor Group  
4
02.97  
PEB 2055  
PEF 2055  
Table of Contents  
Page  
4.2.6.8 Version Number Status Register (VNSR) . . . . . . . . . . . . . . . . . . . . . . . . . . .82  
5
5.1  
5.1.1  
5.2  
5.2.1  
Application Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83  
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83  
IOM® and SLD Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83  
Configuration of Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89  
PCM Interface Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89  
5.2.1.1 PCM Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89  
5.2.1.2 PCM Interface Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89  
5.2.1.3 PCM Interface Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91  
5.2.2  
Configurable Interface Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102  
5.2.2.1 CFI Interface Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102  
5.2.2.2 CFI Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102  
5.2.2.3 CFI Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104  
5.3  
Data and Control Memories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130  
Memory Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130  
Indirect Register Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131  
Memory Access Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135  
5.3.1  
5.3.2  
5.3.3  
5.3.3.1 Access to the Data Memory Data Field . . . . . . . . . . . . . . . . . . . . . . . . . . . .135  
5.3.3.2 Access to the Data Memory Code (Tristate) Field . . . . . . . . . . . . . . . . . . . .139  
5.3.3.3 Access to the Control Memory Data Field . . . . . . . . . . . . . . . . . . . . . . . . . .142  
5.3.3.4 Access to the Control Memory Code Field . . . . . . . . . . . . . . . . . . . . . . . . . .144  
5.4  
Switched Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151  
CFI - PCM Time Slot Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152  
Subchannel Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156  
Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161  
5.4.1  
5.4.2  
5.4.3  
5.4.3.1 CFI - CFI Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161  
5.4.3.2 PCM - PCM Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164  
5.4.4  
Switching Delays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166  
5.4.4.1 Internal Procedures at the Serial Interfaces . . . . . . . . . . . . . . . . . . . . . . . . .167  
5.4.4.2 How to Determine the Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .170  
5.4.4.3 Example: Switching of Wide Band ISDN Channels with the EPIC® . . . . . . .172  
5.5  
5.5.1  
5.5.2  
Preprocessed Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175  
Initialization of Preprocessed Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . .176  
Control/Signaling (CS) Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187  
5.5.2.1 Registers used in Conjunction with the CS Handler . . . . . . . . . . . . . . . . . .188  
5.5.2.2 Access to Downstream C/I and SIG Channels . . . . . . . . . . . . . . . . . . . . . .190  
5.5.2.3 Access to the Upstream C/I and SIG Channels . . . . . . . . . . . . . . . . . . . . . .191  
5.5.3  
Monitor/Feature Control (MF) Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193  
5.5.3.1 Registers used in Conjunction with the MF Handler . . . . . . . . . . . . . . . . . .195  
5.5.3.2 Description of the MF Channel Commands . . . . . . . . . . . . . . . . . . . . . . . . .200  
5.6  
µP Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208  
Semiconductor Group  
5
02.97  
PEB 2055  
PEF 2055  
Table of Contents  
Page  
5.7  
5.7.1  
5.8  
5.8.1  
5.8.2  
5.8.3  
5.8.4  
5.9  
Synchronous Transfer Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212  
Registers Used in Conjunction with the Synchronous Transfer Utility . . . . .215  
Supervision Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221  
Hardware Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221  
PCM Input Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223  
PCM Framing Supervision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226  
Power and Clock Supply Supervision/Chip Version . . . . . . . . . . . . . . . . . . .227  
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228  
Analog IOM®-2 Line Card with SICOFI®-4 as Codec/Filter Device . . . . . . .228  
IOM®-2 Trunk Line Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232  
5.9.1  
5.9.2  
5.9.2.1 PBX With Multiple ISDN Trunk Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233  
5.9.2.2 Small PBX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .238  
5.9.3  
Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240  
5.9.3.1 Interfacing the EPIC® to a MUSAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240  
5.9.3.2 Space and Time Switch for 16 kbit/s Channels . . . . . . . . . . . . . . . . . . . . . .242  
5.9.3.3 Interfacing an IOM®-2 Terminal Mode Interface  
to a 2.048 Mbit/s PCM Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244  
6
7
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246  
Package Outlines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257  
8
8.1  
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258  
Working Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258  
Register Summary for EPIC® Initialization . . . . . . . . . . . . . . . . . . . . . . . . . .258  
Switching of PCM Time Slots to the CFI Interface (data downstream) . . . .262  
Switching of CFI Time Slots to the PCM Interface (data upstream) . . . . . . .263  
Preparing EPIC®s C/I Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264  
Receiving and Transmitting IOM®-2 C/I-Codes . . . . . . . . . . . . . . . . . . . . . .265  
Development Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266  
SIPB 5000 Mainboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266  
SIPB 5121 IOM®-2 Line Card (EPIC®/IDEC®) . . . . . . . . . . . . . . . . . . . . . . .267  
EPIC® Configurator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268  
8.1.1  
8.1.2  
8.1.3  
8.1.4  
8.1.5  
8.2  
8.2.1  
8.2.2  
8.2.3  
9
Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .269  
9.1  
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .269  
IOM®, IOM®-1, IOM®-2, SICOFI®, SICOFI®-2, SICOFI®-4, SICOFI®-4µC, SLICOFI®, ARCOFI® , ARCOFI®-BA,  
ARCOFI®-SP, EPIC®-1, EPIC®-S, ELIC®, IPAT®-2, ITAC®, ISAC®-S, ISAC®-S TE, ISAC®-P, ISAC®-P TE, IDEC®,  
SICAT®, OCTAT®-P, QUAT®-S are registered trademarks of Siemens AG.  
MUSAC-A, FALC54, IWE, SARE, UTPT, ASM, ASPare trademarks of Siemens AG.  
Purchase of Siemens I2C components conveys a license under the Philips’ I2C patent to use the components in  
the I2C-system provided the system conforms to the I2C specifications defined by Philips. Copyright Philips 1983.  
Semiconductor Group  
6
02.97  
PEB 2055  
PEF 2055  
Overview  
1
Overview  
The PEB 2055 (Extended PCM Interface Controller) is a highly integrated controller  
circuit optimized for analog and ISDN line card and central switches applications. The  
EPIC-1 provides the circuitry necessary to manage up to 32 digital (ISDN or proprietary)  
or 64 analog subscribers.  
The EPIC-1 is dedicated to switch PCM data between two serial interfaces, the system  
interface (PCM interface) and the configurable interface (CFI). The EPIC-1 performs  
non-blocking time and space switching for up to 128 channels.  
Since the system cost of the EPIC-1 is divided by the number of lines it controls, an  
highly economical implementation of digital or analog subscriber lines can be performed.  
The EPIC-S (PEB 2054) is a pin compatible device offering half the switching capacity  
of the EPIC-1. Therefore the EPIC-S is capable of handling up to 16 ISDN or 32 analog  
subscribers. It is programmable according to the EPIC-1 with respect of the pins not  
available.  
The EPIC is implemented in a Siemens advanced CMOS-technology and manufactured  
in a P-LCC-44-1 package.  
The EPIC is member of a chip family supporting a highly economical implementation of  
line cards and subscriber terminals.  
Chip Family  
Line Cards:  
PEB 2055  
PEB 20550  
PEB 2096  
PEB 2095  
PEB 2084  
PEB 2465  
PEB 2075  
Extended PCM Interface Controller  
Extended Line Card Controller  
Octal UPN Transceiver  
ISDN Burst Transceiver Circuit  
Quadruple S0 Transceiver  
(EPIC)  
(ELIC)  
(OCTAT-P)  
(IBC)  
(QUAT-S)  
(SICOFI-4)  
(IDEC)  
Quadruple DSP based Codec Filter  
ISDN D-Channel Exchange Controller  
Terminals:  
PSB 2196  
Digital Subscriber Access Controller  
for UPN Interface  
(ISAC-P TE)  
(SBCX)  
PEB 2081 (V3.2) S/T-Bus Interface Circuit Extended  
Semiconductor Group  
7
Extended PCM Interface Controller  
EPIC®-1, EPIC®-S  
PEB 2055  
PEF 2055  
PEB 2054  
PEF 2054  
Versions A3 (PEB 2055), V1.0 (PEB 2054)  
CMOS  
1.1  
Features  
Switching  
• Board Controller for up to  
– 32 ISDN or 64 analog subscribers (PEB 2055)  
– 16 ISDN or 32 analog subscribers (PEB 2054)  
• Non-blocking switch for  
– 128 channels (PEB 2055)  
– 64 channels (PEB 2054)  
P-LCC-44-1  
• Switching of 16-, 32-, or 64-kbit/s channels  
• Two consecutive 64-kbit/s channels can be switched as a single 128-kbit/s channel  
• Freely programmable time slot assignment for all subscribers  
• Two serial interfaces (PCM and CFI) programmable over a wide data range (128 -  
8192 kbit/s)  
• Data rates of PCM and configurable interface independent from each other (data rate  
adaptation)  
• PCM-interface  
– Tristate control signals for external drivers  
– Programmable clock shift  
– Single or double data clock  
• Configurable interface  
– Configurable for IOM-, SLD- and PCM-applications  
– High degree of flexibility for datastream adaptation  
– Programmable clockshift  
– Single or double data clock  
• Synchronous µP-access to two selected channels  
Type  
Ordering Code  
Q67100-H6035  
Q67100-H6216  
Q67100-H6420  
Q67100-H6534-B701  
Package  
PEB 2055  
PEF 2055  
PEB 2054  
PEF 2054  
P-LCC-44-1  
P-LCC-44-1  
P-LCC-44-1  
P-LCC-44-1  
Semiconductor Group  
8
02.97  
PEB 2055  
PEF 2055  
Overview  
Handling of Layer-1 Functions  
• Change detection for C/I-channel (IOM-configuration) or feature control  
(SLD-configuration)  
• Double last-look logic for C/I-channel (IOM-2 analog configuration)  
• Additional last-look logic for feature control (SLD-configuration)  
• Buffered monitor (IOM-configuration) or signaling channel (SLD-configuration)  
Bus Interface  
• Siemens/Intel or Motorola type µP-interface  
• 8-bit demultiplexed bus interface  
• FIFO-access interrupt or DMA controlled  
1.2  
Pin Configuration  
(top view)  
V
28 27 26 25 24 23 22 21 20 19 18  
R/W,WR  
CS  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
17  
16  
15  
14  
13  
12  
11  
10  
9
PDC  
PFS  
ALE  
TxD3  
TSC3  
TxD2  
TSC2  
TxD1  
TSC1  
TxD0  
TSC0  
A1  
INT  
DCL  
PEB 2055  
EPIC R  
FSC  
DU3/SIP7  
DU2/SIP6  
DU1/SIP5  
DU0/SIP4  
A3  
8
7
40 41 42 43 44  
1
2
3
4
5
6
V
ITP09463  
Figure 1  
Pin Configuration EPIC®-1  
Semiconductor Group  
9
PEB 2055  
PEF 2055  
Overview  
V
28 27 26 25 24 23 22 21 20 19 18  
R/W,WR  
CS  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
17  
16  
15  
14  
13  
12  
11  
10  
9
PDC  
PFS  
ALE  
INT  
TxD3  
TSC3  
TxD2  
TSC2  
TxD1  
TSC1  
TxD0  
TSC0  
A1  
DCL  
FSC  
N.C.  
N.C.  
DU1  
DU0  
A3  
PEB 2054  
EPIC R -S  
8
7
40 41 42 43 44  
1
2
3
4
5
6
V
ITP09530  
Figure 2  
Pin Configuration EPIC®-S  
Semiconductor Group  
10  
PEB 2055  
PEF 2055  
Overview  
1.3  
Pin Definitions and Functions  
Symbol Input (I) Function  
Output (O)  
Pin No.  
EPIC-S EPIC  
30  
30  
CS  
I
Chip Select; active low. A “low” on this line  
selects the EPIC for read/write operations.  
29  
29  
WR,  
R/W  
I
Write, active low, Siemens/Intel bus mode.  
When “low”, a write operation is indicated.  
Read/Write, Motorola bus mode.  
When “high” a valid µP-access identifies a read  
operation, when “low” it identifies a write access.  
28  
28  
RD, DS I  
Read, active low, Siemens/Intel bus mode.  
When “low” a read operation is indicated.  
Data Strobe, Motorola bus mode.  
A rising edge marks the end of a read or write  
operation.  
19  
20  
21  
22  
23  
24  
25  
26  
19  
20  
21  
22  
23  
24  
25  
26  
AD0, D0 I/O  
AD1, D1 I/O  
AD2, D2 I/O  
AD3, D3 I/O  
AD4, D4 I/O  
AD5, D5 I/O  
AD6, D6 I/O  
AD7, D7 I/O  
Address/Data Bus; multiplexed bus mode.  
Transfers addresses from the µP-system to the  
EPIC and data between the µP and the EPIC.  
Data Bus; demultiplexed bus mode.  
Transfers data between the µP and the EPIC.  
When driving data the pins have push pull  
characteristic, otherwise they are in high  
impedance state.  
31  
31  
ALE  
I
Address Latch Enable  
ALE controls the on chip address latch in  
multiplexed bus mode. While ALE is “high”, the  
latch is transparent. The falling edge latches the  
current address. During the first read/write  
access following reset ALE is evaluated to select  
the bus mode.  
32  
32  
INT  
O
Interrupt Request, active low.  
(OD)  
This signal is activated when the EPIC requests  
an interrupt. Due to the open drain (OD)  
characteristic of INT multiple interrupt sources  
can be connected together.  
44  
16  
44  
16  
RES  
PFS  
I
I
Reset  
A “high” forces the EPIC into reset state.  
PCM Interface Frames Synchronization  
Semiconductor Group  
11  
PEB 2055  
PEF 2055  
Overview  
1.3  
Pin Definitions and Functions (cont’d)  
Pin No.  
EPIC-S EPIC  
Symbol Input (I)  
Output (O)  
Function  
17  
17  
PDC  
I
PCM Interface Data Clock  
Single or double data rate.  
6
5
4
3
6
5
4
3
RxD0  
RxD1  
RxD2  
RxD3  
I
I
I
I
Receive PCM Interface Data  
Time-slot oriented data is received on this pins  
and forwarded into the downstream data memory  
of the EPIC.  
9
9
TxD0  
TxD1  
TxD2  
TxD3  
O
O
O
O
Transmit PCM Interface Data  
11  
13  
15  
11  
13  
15  
Time slot oriented data is shifted out of the  
EPIC’s upstream data memory on this lines. For  
time-slots which are flagged in the tristate  
data memory or when bit OMDR:PSB is reset  
the pins are set to high impedance state.  
8
8
TSC0  
TSC1  
TSC2  
TSC3  
O
O
O
O
Tristate Control  
10  
12  
14  
10  
12  
14  
Supplies a control signal for an external driver.  
These lines are “low” when the corresponding  
TxD outputs are valid. During reset these lines  
are “high”.  
34  
33  
34  
33  
FSC  
DCL  
I/O  
I/O  
Frame Synchronization  
Input or output in IOM configuration. Direction  
indication signal in SLD mode.  
Data Clock  
Input or output in IOM, slave clock in SLD  
configuration. In IOM configuration single or  
double data rate, single data rate in SLD mode.  
38  
37  
-
38  
37  
DU0/SIP4 I/IO (OD)  
DU1/SIP5 I/IO (OD)  
Data Upstream Input; IOM or PCM configuration.  
Serial Interface Port, SLD configuration.  
Depending on the bit OMDR:COS these lines  
have push pull or open drain characteristic.  
For unassigned channels or when bit  
OMDR:CSB is reset the pins are in the state  
high impedance.  
36 * DU2/SIP6 I/IO (OD)  
35 * DU3/SIP7 I/IO (OD)  
-
* Note: EPIC-1 only  
Semiconductor Group  
12  
PEB 2055  
PEF 2055  
Overview  
1.3  
Pin Definitions and Functions (cont’d)  
Symbol Input (I) Function  
Output (O)  
Pin No.  
EPIC-S EPIC  
40  
41  
-
40  
41  
DD0/SIP0 O/IO (OD) Data Downstream Output, IOM or PCM  
DD1/SIP1 O/IO (OD) configuration.  
42 * DD2/SIP2 O/IO (OD) Serial Interface Port, SLD configuration.  
43 * DD3/SIP3 O/IO (OD) Depending on the bit OMDR:COS these lines  
have push pull or open drain characteristic.  
For unassigned channels or when bit  
-
OMDR:CSB is reset the pins are in the high  
impedance state.  
* Note: EPIC-1 only  
2
7
18  
39  
2
7
18  
39  
A0  
A1  
A2  
A3  
I/O  
Address bus in the demultiplexed µP interface  
mode.  
1
1
VDD  
VSS  
I
I
Supply voltage: 5 V ± 5%  
27  
27  
Ground: 0 V  
Semiconductor Group  
13  
PEB 2055  
PEF 2055  
Overview  
1.4  
Logic Symbols  
PDC  
PFS  
DCL  
FSC  
TxD 0  
TSC 0  
RxD 0  
PCM  
Port 0  
DU  
DD  
0
0
CFI  
Port 0  
TxD 1  
TSC 1  
RxD 1  
PCM  
Port 1  
DU  
DD  
1
1
EPIC R -1  
CFI  
Port 1  
TxD 2  
TSC 2  
RxD 2  
DU  
DD  
2
2
CFI  
Port 2  
PCM  
Port 2  
DU  
DD  
3
3
CFI  
Port 3  
TxD 3  
TSC 3  
RxD 3  
PCM  
Port 3  
AD7...0  
A3...0 RD  
WR  
ALE  
CS  
INT  
ITL09531  
Figure 3  
Logic Symbol of the EPIC®-1  
Semiconductor Group  
14  
PEB 2055  
PEF 2055  
Overview  
PDC  
PFS  
DCL  
FSC  
TxD 0  
TSC 0  
RxD 0  
PCM  
Port 0  
DU  
DD  
0
0
CFI  
Port 0  
TxD 1  
TSC 1  
RxD 1  
PCM  
Port 1  
DU  
DD  
1
1
EPIC R -S  
CFI  
Port 1  
TxD 2  
TSC 2  
RxD 2  
PCM  
Port 2  
TxD 3  
TSC 3  
RxD 3  
PCM  
Port 3  
ITL09532  
AD7...0  
A3...0 RD  
WR  
ALE  
CS  
INT  
Figure 4  
Logic Symbol of the EPIC®-S  
Semiconductor Group  
15  
PEB 2055  
PEF 2055  
Overview  
1.5  
Functional Block Diagram  
RES  
DCL / SCL  
PDC  
PFS  
Timer  
FSC / DIR  
RxD0  
TxD0  
TSC0  
RxD1  
DD0/ SIP0  
DU0/ SIP4  
DD1/ SIP1  
DU1/ SIP5  
TxD1  
TSC1  
RxD2  
Data Memory  
DD2/ SIP2  
DU2/ SIP6  
TxD2  
TSC2  
RxD3  
TxD3  
TSC3  
DD3/ SIP3  
DU3/ SIP7  
Control Memory  
Layer 1  
Controller  
Buffer  
µP Interface  
AD7...0 WR RD ALE CS INT A3...0  
ITB09533  
Figure 5  
Functional Block Diagram EPIC®  
Semiconductor Group  
16  
PEB 2055  
PEF 2055  
Overview  
1.6  
Using the EPIC-S  
The EPIC-S is based on the same technology as the EPIC-1 aside from only providing  
CFI port 0 and CFI port 1. Therefore this User’s Manual applies to both, the EPIC-S and  
the EPIC-1.  
When using the EPIC-S the user has to be aware not to program connections that would  
imply the not supported CFI ports.  
The following points require specific attention:  
1. During power up the EPIC-S must be supplied with an external Hardware Reset.  
2. Register bit OMDR:CSB may be programmed to high (switch off standby of CFI  
interface) only after a Control Memory reset procedure with MACR:CMC3..0 = 0H.  
3. The pins not available with respect to the EPIC-1 (PEB 2055) must not be  
programmed as outputs.  
Semiconductor Group  
17  
PEB 2055  
PEF 2055  
Overview  
1.7  
System Integration and Application  
The main application fields of the EPIC are:  
– Digital line cards with different architectures,  
– Central control units of key systems,  
– Analog line cards,  
– Concentrators.  
1.7.1  
Digital Line Card  
1.7.1.1 Switching, Layer-1 Control  
The EPIC provides a switching capability for up to 32 digital subscribers between the  
PCM system highway and the IOM-2 interface (64 B-channels). Typically it switches  
64-kbit/s channels between the PCM and the IOM-interfaces. Moreover it is able to  
handle also 16-, 32- and 128-kbit/s channels.  
The signaling handler supports the command/indication (C/I) channel which is used to  
exchange predefined layer-1 information with the transceiver device.  
A monitor handler supports the handshake protocol defined on the IOM-monitor channel.  
It allows programming of layer-1 devices which do not have a dedicated µP interface.  
The EPIC can be operated in tandem, i.e. one device is active, another one is a backup  
device. The backup device can instantaneously take over from the active device when  
the active device fails. Due to this tandem operation capability and the high number of  
ISDN subscribers which can be connected to one EPIC, the use of single line cards is  
feasible.  
Several line card architectures are possible.  
1.7.1.2 Decentralized D-Channel Handling  
In completely decentral D-channel processing architectures (see figure 6), the  
processing capacity of the line card is usually designed to avoid blocking situations even  
under maximum conceivable D-channel traffic conditions. In such an architecture the  
EPIC switches the B-channels and performs C/I and monitor channel control.  
The IDECs handle the layer 2 functions for signaling and data packets in the D-channel.  
They transfer the extracted data via the µP and an HDLC controller, e.g. the HSCX (High  
Level Serial Controller Extended SAB 82525) to the system. One of the channels of the  
HSCX may access either a time slot of programmable bandwidth on one of the system  
highways or a separate signalling highway.  
In both cases the highway capacity used for packet traffic can be shared among several  
line cards due to the statistical multiplexing capabilities of the HSCX.  
Semiconductor Group  
18  
PEB 2055  
PEF 2055  
Overview  
Example Frame Structure  
...  
IOM R -2 Interface  
B
B
B
B
B
S
B
PCM  
Highway  
R
EPIC  
s + p  
Data  
R
R
IDEC  
IDEC  
s-Data  
p-Data  
s-Data  
µ
P
HSCX  
Packet Highway with  
Collision Resolution  
ITS09534  
Figure 6  
Line Card Architecture for Completely Decentral D-Channel Processing  
Semiconductor Group  
19  
PEB 2055  
PEF 2055  
Overview  
1.7.1.3 Central D-Channel Processing  
In this application the EPIC not only switches the B-channels and performs the C/I- and  
monitor channel control function, but switches also the D-channel data onto the system  
highway. In upstream direction the EPIC can combine up to four 16-kbit/s D-channels  
into one 64-kbit/s channel. In downstream direction it provides the capability to distribute  
one 64-kbit/s channel to four 16-kbit/s channels.  
B, D  
Example Frame Structure  
...  
B
B
B
D D D D  
B
IOM R -2  
Interface  
PCM  
Highway  
EPIC R  
Signaling  
Highway  
µ
P
HSCX  
ITS09535  
Figure 7  
Digital Line Card Architecture with a Completely Central D-Channel Handling  
Semiconductor Group  
20  
PEB 2055  
PEF 2055  
Overview  
1.7.1.4 Mixed D-Channel Processing, Signaling Decentralized,  
Packet Data Centralized  
Another possibility is a mixed architecture with centralized packet data and decentralized  
signaling handling. This is a very flexible architecture which reduces the dynamic load of  
central processing units by evaluating the signaling information on the line card, but does  
not require resources for packet data handling. Any increase of packet data traffic does  
not necessitate a change in the line card architecture, the central packet handling unit  
can be expanded.  
In this application IDECs are employed to handle the data on the D-channel. The IDECs  
separate signaling information from data packets. The signaling messages are  
transferred to the µP, which in turn hands them over to the group controller using the  
HSCX.  
The packet data is processed differently. Together with the collision resolution  
information it is transferred to one IOM-2 port of the EPIC. The EPIC switches the  
channels to the PCM-highway, optionally combining four D-channels to one 64-kbit/s  
channel. In this configuration one IOM-2 interface is occupied by IDECs, reducing the  
total switching capability of the EPIC-1 to 24 ISDN-subscribers.  
B, P, C  
Example Frame Structure  
...  
IOM R -2 Interface  
p - Data  
B
B
B
P
B
C
B
Packet Collision  
Data Data  
P + Coll  
P
EPIC R  
PCM  
Highway  
Sig.  
Data  
R
R
IDEC  
IDEC  
Signaling  
S
HSCX  
Signaling  
Highway  
µ
P
ITS09536  
Figure 8  
Line Card Architecture for Mixed D-Channel Processing  
Semiconductor Group  
21  
PEB 2055  
PEF 2055  
Overview  
Alternatively, the packet and collision data can be directly exchanged between the  
IDECs and the PCM-highway. Thus, the full 32 subscriber switching capability of the  
EPIC is retained.  
IOM R -2 Interface  
PCM Interface  
B, P  
B, P  
Coll  
B
System  
Highway  
EPIC R  
S
S
Signaling  
Highway  
µ
C
HSCX  
S
D
P
P
Coll  
R
IDEC  
ITS09537  
Figure 9  
Line Card Architecture for Mixed D-Channel Processing  
Semiconductor Group  
22  
PEB 2055  
PEF 2055  
Overview  
1.7.2  
Analog Line Card  
Together with the highly flexible Siemens codec filter circuits SLICOFI, SICOFI,  
SICOFI-2 or SICOFI-4 the EPIC constitutes an optimized analog subscriber board  
architecture.  
The EPIC-1 handles the signalling and voice data for up to 64 subscriber channels with  
64 kbit/s. The HSCX establishes the link to the group controller board.  
B Channels  
IOM R -2  
PCM Highway  
SICOFI R -4  
SICOFI R -4  
IOM R -2  
SICOFI R -4  
SICOFI R -4  
SICOFI R -4  
SICOFI R -4  
SICOFI R -4  
SICOFI R -4  
EPIC R  
IOM R -2  
IOM R -2  
C/I, Monitor  
Channel  
Signaling Highway  
HSCX  
µ
P
ITS09538  
Figure 10  
Line Card Architecture for Analog Subscribers  
Semiconductor Group  
23  
PEB 2055  
PEF 2055  
Overview  
1.7.3  
Packet Handlers  
The EPIC is an important building block for networks based on either central, decentral  
or mixed signaling and packet data handling architectures. Its flexibility allows for the  
modification of the packet handling architecture according to the changing needs.  
Thus it may be useful to add central packet handling groups to a network originally based  
on decentral signaling and packet handling. This may be the case if growing data packet  
traffic exceeds the initial capacity of the network. The result is a mixed architecture.  
On the other hand, increasing packet handling demand on a few dedicated subscriber  
lines calls for solutions which back up the capacity at these few decentral line cards.  
In both of these cases and several other applications, the EPIC is a powerful device for  
solving the problem of packet handling. In most applications it is used together with the  
IDEC (ISDN D channel Exchange Controller).  
Decentralized and mixed packet handling has already been covered in the line card  
chapter. In the following, the centralized signaling/packet handlers built up with the EPIC  
will be described.  
Central packet handling is used if many subscribers with a generally low demand for  
packet switching are to be connected to a system. Concentrating the packet servers for  
multiple users eliminates the need to provide a packet server channel for every user. The  
overall number of packet server channels can thus be reduced.  
In such a central packet handling group, the EPIC performs the switching and  
concentrator function. It connects a variable number of PCM highways to the packet  
handler internal highway. HDLC controllers are also connected to this internal highway  
as illustrated in figure 11.  
PCM Highways  
A
B
C
D
Packet Handler Internal Highway  
EPIC R  
R
R
IDEC  
IDEC  
µ
C
Centralized Packet Handler Unit  
ITS09539  
Figure 11  
Centralized Packet Handler with a Single Internal Highway Connected to 4 PCM  
Highways  
Semiconductor Group  
24  
 
PEB 2055  
PEF 2055  
Overview  
This figure shows one EPIC connecting four PCM highways to one packet handler  
internal highway. These highways are accessed by the IDECs, which are 4 channel  
HDLC controller and handle the packets. If more than four PCM highways shall be  
connected to the centralized packet handler, further EPICs are necessary. Such a  
configuration is shown in figure 12, where 8 highways are switched to one packet  
handler internal highway. In this case the two EPICs are connected in parallel at the  
packet handlers internal side.  
PCM Highways  
A
B
C
D
E
F
G H  
Packet Handler Internal Highway  
S
EPIC R  
R
R
IDEC  
IDEC  
µ
C
EPIC R  
Centralized Packet Handler Unit  
ITS09540  
Figure 12  
Centralized Packet Handler with One Internal Highway Connected to 8 PCM High-  
ways  
The data rate of the packet handler internal highway can be up to 4.096 Mbit/s. If this  
capacity is not sufficient, other packet handler internal highways may be added as  
depicted in figure 13.  
Semiconductor Group  
25  
 
PEB 2055  
PEF 2055  
Overview  
PCM Highways  
A
B
C
D
E
F
G H  
Packet Handler Internal Highway  
S
EPIC R  
R
R
R
IDEC  
IDEC  
IDEC  
µ
C
EPIC R  
Centralized Packet Handler Unit  
ITS09541  
Figure 13  
Centralized Packet Handler with 3 Internal Highways  
In some applications an additional collision resolution signal is required for the HDLC  
controllers. This information can be demultiplexed from the PCM highways to a third line  
for each packet handler internal highway (refer to figure 14).  
PCM Highways  
A
B
C
D
Packet Handler Internal Highway  
S
EPIC R  
Collision  
Indication  
Line  
R
R
IDEC  
IDEC  
µ
C
Centralized Packet Handler Unit  
ITS09542  
Figure 14  
Centralized Packet Handler with Internal Collision Line  
The applications apply equally to centralized signaling as well as to data packet  
handlers.  
Semiconductor Group  
26  
 
PEB 2055  
PEF 2055  
Functional Description  
2
Functional Description  
In the following chapters the functions of the PEB 2055 will be covered in more detail.  
2.1  
Bus Interface  
All registers and the FIFOs of the EPIC are accessible via the flexible bus interface  
supporting Siemens / Intel and Motorola type microprocessors. Depending on the  
register functionality a read, write or read/write access is possible.  
The bus interface consists of the following elements  
• Data bus, 8-bit wide, D7 .. 0  
• Address bus, 4-bit wide, A3 .. 0  
• Chip select, CS  
• Address latch enable, ALE  
• Two read/write control lines: RD and WR (Intel mode) or DS and R/W (Motorola  
mode)  
• Interrupt, INT  
• Reset, RES  
The ALE line is used to control the bus structure and interface type.  
Table 1  
Selectable Bus Configurations  
ALE  
Interface  
Bus Structure  
demultiplexed  
demultiplexed  
multiplexed  
Pin 28  
DS  
Pin 29  
R/W  
WR  
Fixed to VDD  
Fixed to ground  
Switching  
Motorola  
Siemens / Intel  
Siemens / Intel  
RD  
RD  
WR  
D0-7  
A0-3  
DS R/W CS  
D0-7  
A0-3  
RD WR CS  
ALE AD0-7  
RD WR CS  
EPIC R with Siemens/Intel Type  
Interface, Demultiplexed  
Address/Data Bus  
EPIC R with Siemens/Intel Type  
Interface, Multiplexed  
EPIC R with Motorola  
Type Interface  
Address/Data Bus  
ITS09543  
Figure 15  
Selectable Bus Interface Structures  
Semiconductor Group  
27  
PEB 2055  
PEF 2055  
Functional Description  
In order to simplify the use of 8- and 16-bit Siemens / Intel type CPUs, different register  
addresses are defined in multiplexed and demultiplexed bus mode (see chapter 4.1). In  
the multiplexed mode even addresses are used (AD0 always 0).  
For a demultiplexed µP interface mode the OMDR:RBS bit is needed in addition to the  
address lines A3 .. A0. With OMDR:RBS (register bank selection) one of two register  
banks is selected.  
RBS = “1” selects a set of registers used for device initialization (e.g. CFI and PCM  
interface initialization).  
RBS = “0” switches to a group of registers necessary during operation (e.g. connection  
programming).  
The OMDR register containing the RBS bit can be accessed with either value of RBS.  
Interrupts  
An interrupt of the EPIC is indicated by activating the INT line. The detailed cause of the  
request can be determined by reading the ISTA register.  
The INT output is level active. It remains active until all interrupt sources have been  
serviced. If a new status bit is set while an interrupt is being serviced, the INT remains  
active. However, for the duration of a write access to the MASK-register the INT line is  
deactivated. When using an edge-triggered interrupt controller, it is thus recommended  
to rewrite the MASK register at the end of any interrupt service routine.  
Every interrupt source can be selectively masked by setting the respective bit of the  
MASK register. Such masked interrupts will not be indicated in the ISTA register, nor will  
they activate the INT line.  
2.2  
PCM Interface  
The PCM interface formats the data transmitted or received at the PCM highways. It can  
be configured to provide one (max. 8.192 Mbit/s), two (max. 4.096 Mbit/s) or four (max.  
2.048 Mbit/s) PCM-ports, consisting each of a data receive (RxD), a data transmit (TxD)  
and an output tristate indication line (TSC).  
The PCM interface is supplied with a frame signal (PFS) and a PCM clock (PDC). To  
properly clock the PCM interface, a PDC signal with a frequency equal or twice the data  
rate has to be applied to the EPIC.  
Port configuration, data rates, clock shift and sampling conditions are programmable.  
Semiconductor Group  
28  
PEB 2055  
PEF 2055  
Functional Description  
2.3  
Configurable Interface  
In order to optimize the on-board interchip communication, a very flexible serial interface  
is available. It formats the data transmitted or received at the DDn-, DUn- or SIPn-lines.  
Although it is typically used in IOM-2 or SLD-configuration to connect layer-1 devices,  
application specific frame structures can be defined (e.g. to interface ADPCM-  
converters or maintenance blocks).  
Figure 16 shows the IOM-2 Interface structure in Line Card Mode:  
125 µs  
FSC  
DCL  
R
CH0  
CH0  
CH1  
CH1  
CH2  
CH2  
CH3  
CH3  
CH4  
CH4  
CH5  
CH5  
CH6  
CH6  
CH7  
CH7  
CH8  
CH8  
DU  
DD  
IOM  
IOM  
R
M M  
D(2)  
C/I(4)  
B1  
B1  
B2  
B2  
MONITOR  
MONITOR  
for ISDN Lines  
R X  
M M  
R X  
C/I(6)  
for Analog Lines  
ITD00522  
Figure 16  
IOM®-2 Frame Structure with 2.048 Mbit/s Data Rate  
2.4  
Memory Structure and Switching  
The memory block of the EPIC performs the switching functionality.  
It consists of four sub blocks:  
– Upstream data memory  
– Downstream data memory  
– Upstream control memory  
– Downstream control memory.  
The PCM-interface reads periodically from the upstream (writes periodically to the  
downstream) data memory (cyclical access), see figure 17.  
Semiconductor Group  
29  
 
PEB 2055  
PEF 2055  
Functional Description  
The CFI reads periodically the control memory and uses the extracted values as pointers  
to write to the upstream (read from the downstream) data memory (random access). In  
the case of C/I- or signaling channel applications the corresponding data is stored in the  
control memory. In order to select the application of choice, the control memory provides  
a code portion.  
The control memory is accessible via the µP-interface. In order to establish a connection  
between CFI time slot A and PCM-interface time slot B, the B-pointer has to be loaded  
into the control memory location A.  
Upstream  
Data Memory (DM)  
DATA CODE  
0
TxD#  
PCM  
RxD#  
8 Bits  
4 Bits  
DU#  
CFI  
127  
0
Control  
Memory  
(CM)  
DATA CODE  
8 Bits  
4 Bits  
127  
Data Memory (DM)  
Downstream  
0
DATA  
8 Bits  
DD#  
127  
0
Control  
Memory  
(CM)  
DATA CODE  
8 Bits 4 Bits  
127  
ITS05823  
µP  
Figure 17  
EPIC®-1 Memory Structure  
Semiconductor Group  
30  
PEB 2055  
PEF 2055  
Functional Description  
2.5  
Pre-processed Channels, Layer-1 Support  
The EPIC supports the monitor/feature control and control/signalling channels according  
to SLD or IOM-2 interface protocol.  
The monitor handler controls the data flow on the monitor/feature control channel either  
with or without an active handshake protocol. To reduce the dynamic load of the CPU a  
16-byte transmit/receive FIFO is provided.  
The signaling handler supports different schemes (D-channel + C/I-channel, 6-bit  
signaling, 8-bit signaling).  
In downstream direction the relevant content of the control memory is transmitted in the  
appropriate CFI time slot. In the case of centralized ISDN D-channel handling, a  
16-kbit/s D-channel received at the PCM-interface is included.  
In upstream direction the signaling handler monitors the received data. Upon a change  
it generates an interrupt, the channel address is stored in the 9-byte deep C/I FIFO and  
the actual value is stored in the control memory. In 6-bit and 8-bit signaling schemes a  
double last look check is provided.  
.
2.6  
Special Functions  
– Synchronous transfer.  
This utility allows the synchronous µP-access to two independent channels on the  
PCM or CFI interface. Interrupts are generated to indicate the appropriate access  
windows.  
– 7-bit hardware timer.  
The timer can be used to cyclically interrupt the CPU, to determine the double last look  
period, to generate a proper CFI-multiframe synchronization signal or to generate a  
defined RESIN pulse width.  
– Frame length checking.  
The PFS period is internally checked against the programmed frame length.  
– Alternative input functions.  
In PCM mode 1 and 2, the unused ports can be used for redundancy purposes. In  
these modes, for every active input port a second input port exists which can be  
connected to a redundant PCM line. Additionally the two lines are checked for  
mismatches.  
Semiconductor Group  
31  
PEB 2055  
PEF 2055  
Operational Description  
3
Operational Description  
The EPIC, designed as a flexible line-card controller, has the following main  
applications:  
– Digital line cards, with the CFI typically configured as IOM-2, IOM-1 (MUX) or SLD.  
– Analog line cards, with the CFI typically configured as IOM-2 or SLD.  
– Key systems, where the EPIC’s ability to mix CFI configurations is utilized.  
To operate the EPIC the user must be familiar with the device’s microprocessor  
interface, interrupt structure and reset logic.  
3.1  
Microprocessor Interface Operation  
The EPIC is programmed via an 8-bit parallel interface that can be selected to be  
(1) Motorola type, with control signals DS, R/W and CS.  
(2) Siemens / Intel non-multiplexed bus type, with control signals WR, RD  
and CS.  
(3) Siemens / Intel multiplexed address/data bus type, with control signals  
ALE, WR, RD, and CS.  
The selection is performed via pin ALE as follows:  
ALE tied to VDD  
ALE tied to VSS  
Edge on ALE  
(1)  
(2)  
(3)  
The occurrence of an edge on ALE, either positive or negative, at any time during the  
operation immediately selects interface type (3). A return to one of the other interface  
types is only possible by issuing a hardware reset.  
In order to simplify the use of 8- and 16-bit Siemens / Intel type CPUs, different register  
addresses are defined in multiplexed and demultiplexed bus mode (see chapter 4.1). In  
the multiplexed mode even addresses are used (AD0 always 0).  
For a demultiplexed µP interface mode the OMDR:RBS bit is needed in addition to the  
address lines A3 .. A0. With OMDR:RBS (register bank selection) one of two register  
banks is selected.  
RBS = “1” selects a set of registers used for device initialization (e.g. CFI and PCM  
interface initialization).  
RBS = “0” switches to a group of registers necessary during operation (e.g. connection  
programming).  
The OMDR register containing the RBS bit can be accessed with either value of RBS.  
Semiconductor Group  
32  
PEB 2055  
PEF 2055  
Operational Description  
Interrupts  
An interrupt of the EPIC is indicated by activating the INT line. The detailed cause of the  
request can be determined by reading the ISTA register.  
The INT-output is level active. It remains active until all interrupt sources have been  
serviced. If a new status bit is set while an interrupt is being serviced, the INT remains  
active. However, for the duration of a write access to the MASK-register the INT line is  
deactivated. When using an edge-triggered interrupt controller, it is thus recommended  
to rewrite the MASK-register at the end of any interrupt service routine.  
Every interrupt source can be selectively masked by setting the respective bit of the  
MASK register. Such masked interrupts will not be indicated in the ISTA register, nor will  
they activate the INT line.  
3.2  
Clocking  
To operate properly, the EPIC always requires a PDC-clock.  
To synchronize the PCM side, the EPIC should normally also be provided with a PFS  
strobe. In most applications, the DCL and FSC will be output signals of the EPIC, derived  
from the PDC via prescalers.  
If the required CFI data rate cannot be derived from the PDC, DCL and FSC can also be  
programmed as input signals. This is achieved by setting the EPIC CMD1:CSS-bit.  
Frequency and phase of DCL and FSC may then be chosen almost independently of the  
frequency and phase of PDC and PFS. However, the CFI clock source must still be  
synchronous to the PCM-interface clock source; i.e. the clock source for the CFI  
interface and the clock source for the PCM-interface must be derived from the same  
master clock.  
Chapter 5.2.2 provides further details on clocking.  
3.3  
Reset  
A reset pulse of at least 4 PDC clock cycles has to be applied at the RES pin. The reset  
pulse sets all registers to their reset values described in section 4.  
The EPIC is now in CM reset mode (refer to 4.2.6.7). As the hardware reset does not  
affect the EPIC memories CM and DM, a “software reset” of the CM has to be performed.  
Subsequently the EPIC can be programmed to CM initialization, normal operation or test  
mode.  
During reset the address latch enable pin ALE is evaluated to determine the bus  
interface type.  
Semiconductor Group  
33  
PEB 2055  
PEF 2055  
Operational Description  
3.4  
EPIC® Operation  
The EPIC is principally an intelligent switch of PCM data between two serial interfaces,  
the system interface (PCM interface) and the configurable interface (CFI). Up to 128  
channels per direction can be switched dynamically between the CFI and the PCM-  
interfaces. The EPIC performs non-blocking space and time switching for these  
channels which may have a bandwidth of 16, 32, 64 or 128 kbit/s.  
Both interfaces can be programmed to operate at different data rates of up to  
8.192 Mbit/s. The PCM interface consists of up to four duplex ports with a tristate control  
signal for each output line. The configurable interface can be selected to provide either  
four duplex ports or 8 bi-directional (I/O) ports (EPIC-S: two duplex or 4 bi-directional  
ports).  
The configurable interface incorporates a control block (layer-1 buffer) which allows the  
µP to gain access to the control channels of an IOM (ISDN-Oriented Modular) or SLD  
(Subscriber Line Data) interface. The EPIC can handle the layer-1 functions buffering  
the C/I and monitor channels for IOM compatible devices and the feature control and  
signaling channels for SLD compatible devices. One major application of the EPIC is  
therefore as line card controller on digital and analog line cards. The layer-1 and codec  
devices are connected to the CFI, which is then configured to operate as IOM-2, SLD or  
multiplexed IOM-1 interface.  
The configurable interface of the EPIC can also be configured as plain PCM-interface  
i.e. without IOM- or SLD-frame structure. Since it’s possible to operate the two serial  
interfaces at different data rates, the EPIC can then be used to adapt two different PCM  
systems.  
The EPIC-1 can handle up to 32 ISDN-subscribers with their 2B + D channel structure  
or up to 64 analog subscribers with their 1B channel structure in IOM-configuration. In  
SLD- configuration up to 16 analog subscribers can be accommodated.  
The EPIC-S can handle up to 16 ISDN-subscribers with their 2B + D channel structure  
or up to 32 analog subscribers with their 1B channel structure in IOM-configuration. In  
SLD- configuration up to 8 analog subscribers can be accommodated.  
The system interface is used for the connection to a PCM backplane. On a typical digital  
line card, the EPIC switches the ISDN B channels and, if required, also the D channels  
to the PCM backplane. Due to its capability to dynamically switch the 16-kbit/s  
D channel, the EPIC is one of the fundamental building blocks for networks with either  
central, decentral or mixed signaling and packet data handling architecture.  
Semiconductor Group  
34  
PEB 2055  
PEF 2055  
Operational Description  
3.4.1  
PCM-Interface  
The serial PCM interface provides up to four duplex ports consisting each of a data  
transmit (TxD), a data receive (RxD) and a tristate control (TSC) line. The transmit  
direction is also referred to as the upstream direction, whereas the receive direction is  
referred to as the downstream direction.  
Data is transmitted and received at normal TTL / CMOS-levels, the output drivers being  
of the tristate type. Unassigned time slots may be either be tristated, or programmed to  
transmit a defined idle value. The selection of the states “high impedance” and “idle  
value” can be performed with a two bit resolution. This tristate capability allows several  
devices to be connected together for concentrator functions. If the output driver  
capability of the EPIC should prove to be insufficient for a specific application, an  
external driver controlled by the TSC can be connected.  
The PCM-standby function makes it possible to switch all PCM-output lines to high  
impedance with a single command. Internally, the device still works normally. Only the  
output drivers are switched off.  
The number of time slots per 8-kHz frame is programmable in a wide range (from 4 to  
128). In other words, the PCM-data rate can range between 256 kbit/s up to  
8.192 Mbit/s. Since the overall switching capacity is limited to 128 time slots per  
direction, the number of PCM-ports also depends on the required number of time slots:  
in case of 32 time slots per frame (2.048 Mbit/s) for example, four highways are  
available, in case of 128 time slots per frame (8.192 Mbit/s), only one highway is  
available.  
The partitioning between number of ports and number of bits per frame is defined by the  
PCM mode. There are three PCM-modes.  
The timing characteristics at the PCM interface (data rate, bit shift, etc.) can be varied in  
a wide range, but they are the same for each of the four PCM ports, i.e. if a data rate of  
2.048 Mbit/s is selected, all four ports run at this data rate of 2.048 Mbit/s.  
The PCM-interface has to be clocked with a PCM Data Clock (PDC) signal having a  
frequency equal to or twice the selected PCM-data rate. In single clock rate operation,  
a frame consisting of 32 time slots, for example, requires a PDC of 2.048 MHz. In double  
clock rate operation, however, the same frame structure would require a PDC of  
4.096 MHz.  
For the synchronization of the time slot structure to an external PCM system, a PCM  
Framing Signal (PFS) must be applied. The EPIC evaluates the rising PFS edge to  
reset the internal time slot counters. In order to adapt the PFS timing to different timing  
requirements, the EPIC can latch the PFS-signal with either the rising or the falling PDC  
edge. The PFS signal defines the position of the first bit of the internal PCM frame. The  
actual position of the external upstream and downstream PCM frames with respect to  
the framing signal PFS can still be adjusted using the PCM offset function of the EPIC.  
Semiconductor Group  
35  
PEB 2055  
PEF 2055  
Operational Description  
The offset can then be programmed such that PFS marks any bit number of the external  
frame.  
Furthermore it is possible to select either the rising or falling PDC-clock edge for  
transmitting and sampling the PCM-data.  
Usually, the repetition rate of the applied framing pulse PFS is identical to the frame  
period (125 µs). If this is the case, the loss of synchronism indication function can  
be used to supervise the clock and framing signals for missing or additional clock cycles.  
The EPIC checks the PFS-period internally against the duration expected from the  
programmed data rate. If, for example, double clock operation with 32 time slots per  
frame is programmed, the EPIC expects 512 clock periods within one PFS period. The  
synchronous state is reached after the EPIC has detected two consecutive correct  
frames. The synchronous state is lost if one bad clock cycle is found. The  
synchronization status (gained or lost) can be read from an internal register and each  
status change generates an interrupt.  
3.4.2  
Configurable Interface  
The serial configurable interface (CFI) can be operated either in duplex modes or in a bi-  
directional mode.  
In duplex modes the EPIC-1 provides up to four ports (EPIC-S: up to two ports)  
consisting each of a data output (DD) and a data input (DU) line. The output pins are  
called “Data Downstream” pins and the input pins are called “Data Upstream” pins.  
These modes are especially suited to realize a standard serial PCM interface (PCM  
highway) or to implement an IOM (ISDN-Oriented Modular) interface. The IOM interface  
generated by the EPIC offers all the functionality like C/I- and monitor channel handling  
required for operating all kinds of IOM compatible layer-1 and codec devices.  
In bi-directional mode the EPIC-1 provides eight bi-directional ports (SIP), the EPIC-S  
four bi-directional ports, respectively. Each time slot at any of these ports can individually  
be programmed as input or output. This mode is mainly intended to realize an SLD  
interface (Serial Line Data). In case of an SLD interface the frame consists of eight time  
slots where the first four time slots serve as outputs (downstream direction) and the last  
four serve as inputs (upstream direction). The SLD interface generated by the EPIC  
offers signaling and feature control channel handling.  
Data is transmitted and received at normal TTL/CMOS-levels at the CFI. Tristate or  
open drain output drivers can be selected. In case of open drain drivers, external  
pull-up resistors are required. Unassigned output time slots may be switched to high  
impedance or be programmed to transmit a defined idle value. The selection between  
the states “high impedance” or “idle value” can be performed on a per time slot basis.  
The CFI-standby function switches all CFI-output lines to high impedance with a single  
command. Internally the device still works normally, only the output drivers are switched  
off.  
Semiconductor Group  
36  
PEB 2055  
PEF 2055  
Operational Description  
The number of time slots per 8-kHz frame is programmable from 2 to 128. In other words,  
the CFI-data rate can range between 128 kbit/s up to 8.192 Mbit/s. Since the overall  
switching capacity is limited to 128 time slots per direction, the number of CFI- ports also  
depends on the required number of time slots: in case of 32 time slots per frame  
(2.048 Mbit/s) for example, four (EPIC-S: two) highways are available, in case of  
128 time slots per frame (8.192 Mbit/s), only one highway is available. Usually, the  
number of bits per 8-kHz frame is an integer multiple of the number of time slots per  
frame (1 time slot = 8 bits).  
The timing characteristics at the CFI (data rate, bit shift, etc.) can be varied in a wide  
range, but they are the same for each of the four (EPIC-S: two) CFI-ports, i.e. if a data  
rate of 2.048 Mbit/s is selected, all four (EPIC-S: two) ports run at this data rate of  
2.048 Mbit/s. It is thus not possible to have one port used in IOM-2 line card mode  
(2.048 Mbit/s) while another port is used in IOM-2 terminal mode (768 kbit/s)!  
The clock and framing signals necessary to operate the configurable interface may be  
derived either from the clock and framing signals of the PCM interface (PDC and PFS  
pins), or may be fed in directly via the DCL and FSC pins.  
In the first case, the CFI data rate is obtained by internally dividing down the PCM clock  
signal PDC. Several prescaler factors are available to obtain the most commonly used  
data rates. A CFI reference clock (CRCL) is generated out of the PDC-clock. The PCM-  
framing signal PFS is used to synchronize the CFI-frame structure. Additionally, the  
EPIC generates clock and framing signals as outputs to operate the connected  
subscriber circuits such as layer-1 and codec filter devices. The generated data clock  
DCL has a frequency equal to or twice the CFI data rate. The generated framing signal  
FSC can be chosen from a great variety of types to suit the different applications: IOM-2,  
multiplexed IOM-1, SLD, etc.  
Note that if PFS is selected as the framing signal source, the FSC signal is an output  
with a fixed timing relationship with respect to the CFI data lines. The relationship  
between FSC and the CFI frame depends only on the selected FSC-output wave form  
(CMD2 register). The CFI offset function shifts both the frame and the FSC output signal  
with respect to the PFS signal.  
In the second case, the CFI data rate is derived from the DCL-clock, which is now used  
as an input signal. The DCL clock may also first be divided down by internal prescalers  
before it serves as the CFI reference clock CRCL and before defining the CFI data rate.  
The framing signal FSC is used to synchronize the CFI frame structure.  
Semiconductor Group  
37  
PEB 2055  
PEF 2055  
Operational Description  
3.4.3  
Switching Functions  
The major tasks of the EPIC part is to dynamically switch PCM data between the serial  
PCM interface, the serial configurable interface (CFI) and the parallel µP interface. All  
possible switching paths are shown in figure 18.  
R
EPIC  
1
2
C
F
I
P
C
M
3
4
5
6
µP Interface  
µP  
ITS05844  
Figure 18  
Switching Paths Inside the EPIC®-1  
Note: The time slot selections in upstream direction are completely independent of the  
time slot selections in downstream direction.  
Note: The same applies for the EPIC-S with the exception that only two CFI ports are  
provided.  
CFI - PCM Time Slot Assignment  
Switching paths 1 and 2 of figure 18 can be realized for a total number of 128 channels  
(EPIC-S: 64) per path, i.e. 128 (EPIC-S: 64) time slots in upstream and 128 (EPIC-S: 64)  
time slots in downstream direction. To establish a connection, the µP writes the  
addresses of the involved CFI and PCM time slots to the control memory. The actual  
transfer is then carried out frame by frame without further µP intervention.  
The switching paths 5 and 6 can be realized by programming time slot assignments in  
the control memory. The total number for such loops is limited to the number of available  
time slots at the respective opposite interface, i.e. looping back a time slot from CFI to  
CFI requires a spare upstream PCM time slot and looping back a time slot from PCM to  
PCM requires a spare downstream and upstream CFI time slot.  
Semiconductor Group  
38  
 
PEB 2055  
PEF 2055  
Operational Description  
Time slot switching is always carried out on 8-bit time slots, the actual position and  
number of transferred bits can however be limited to 4-bit or 2-bit sub time slots within  
these 8-bit time slots. On the CFI side, only one sub time slot per 8-bit time slot can be  
switched, whereas on the PCM-interface up to 4 independent sub time slots can be  
switched.  
Examples are given in chapter 5.3.  
Sub Time Slot Switching  
Sub time slot positions at the PCM-interface can be selected at random, i.e. each single  
PCM time slot may contain any mixture of 2- and 4-bit sub time slots. A PCM time slot  
may also contain more than one sub time slot. On the CFI however, two restrictions must  
be observed:  
– Each CFI time slot may contain one and only one sub time slot.  
– The sub-slot position for a given bandwidth within the time slot is fixed on a per port  
basis.  
For more detailed information on sub-channel switching please refer to chapter 5.4.2.  
µP Transfer  
Switching paths 3 and 4 of figure 18 can be realized for all available time slots. Path 3  
can be implemented by defining the corresponding CFI time slots as “µP channels” or as  
“pre-processed channels”.  
Each single time slot can individually be declared as “µP channel”. If this is the case, the  
µP can write a static 8-bit value to a downstream time slot which is then transmitted  
repeatedly in each frame until a new value is loaded. In upstream direction, the µP can  
read the received 8-bit value whenever required, no interrupts being generated.  
The “pre-processed channel” option must always be applied to two consecutive time  
slots. The first of these time slots must have an even time slot number. If two time slots  
are declared as “pre-processed channels”, the first one can be accessed by the  
monitor/feature control handler, which gives access to the frame via a 16-byte FIFO.  
Although this function is mainly intended for IOM- or SLD-applications, it could also be  
used to transmit or receive a “burst” of data to or from a 64-kbit/s channel. The second  
pre-processed time slot, the odd one, is also accessed by the µP. In downstream  
direction a 4-, 6- or 8-bit static value can be transmitted. In upstream direction the  
received 8-bit value can be read. Additionally, a change detection mechanism will  
generate an interrupt upon a change in any of the selected 4, 6 or 8 bits.  
Pre-processed channels are usually programmed after Control Memory (CM) reset  
during device initialization. Resetting the CM sets all CFI time slots to unassigned  
channels (CM code “0000”). Of course, pre-processed channels can also be initialized  
or re-initialized in the operational phase of the device.  
Semiconductor Group  
39  
PEB 2055  
PEF 2055  
Operational Description  
To program a pair of pre-processed channels the correct code for the selected handling  
scheme must be written to the CM. Figure 19 gives an overview of the available pre-  
processing codes and their application. For further detail, please refer to chapter 5.5.  
Even Control Memory Address  
MAAR = 0......0  
Odd Control Memory Address  
MAAR = 0......1  
Output at the Configurable Interface  
Downstream Preprocessed Channels  
DD Application  
Code Field  
Data Field  
Code Field  
Data Field  
Even Time-Slot  
Odd Time-Slot  
MACR = 0111...  
MADR = ......  
MACR = 0111...  
MADR = ......  
Decentral  
D Channel  
Handling  
m m m m m m m m  
Monitor Channel  
-
-
C/I  
m m  
1
1
0
0
0
1
0
0
1
1
1
1
C/I  
C/I  
1
1
1
1
1
0
1
1
X X X X X X X X  
Control Channel  
Central  
D Channel  
Handling  
PCM Code for  
a 2 Bit Sub.  
Time-Slot  
m m m m m m m m D D  
C/I  
m m  
Pointer to a PCM Time-Slot  
Monitor Channel  
Control Channel  
6 Bit  
Signaling  
(e.g. analog  
m m m m m m m m  
Monitor Channel  
SIG  
m m  
1
1
0
0
1
1
0
0
SIG  
1
1
1
1
0
0
1
1
1
1
X
X
X
X
X
X
X X  
X X  
X
X
X
X
X
X
Control Channel  
IOM R  
)
8 Bit  
Signaling  
(e.g. SLD)  
m m m m m m m m  
SIG  
SIG  
Feature Control Channel Signaling Channel  
Even Control Memory Address  
MAAR = 1......0  
Odd Control Memory Address  
MAAR = 1......1  
Input from the Configurable Interface  
Upstream Preprocessed Channels  
DD Application  
Code Field  
Data Field  
MADR = ......  
Code Field  
Data Field  
MADR = ......  
Even Time-Slot  
Odd Time-Slot  
MACR = 0111...  
MACR = 0111...  
Decentral  
D Channel  
Handling  
m m m m m m m m  
Monitor Channel  
-
-
C/I  
m m  
1
1
0
0
0
0
0
0
1
1
1
1
C/I  
C/I  
1
1
1
1
0
0
0
0
X
X
X
X X  
X
X
X
Control Channel  
Central  
D Channel  
Handling  
PCM Code for  
a 2 Bit Sub.  
Time-Slot  
m m m m m m m m D D  
C/I  
m m  
Pointer to a PCM Time-Slot  
Monitor Channel  
Control Channel  
6 Bit  
Signaling  
(e.g. analog  
m m m m m m m m  
Monitor Channel  
SIG  
m m  
1
1
0
0
1
1
0
1
SIG Actual Value  
X
X
1
1
0
0
1
1
0
1
SIG Stable Value  
X X  
Control Channel  
IOM R  
)
8 Bit  
Signaling  
(e.g. SLD)  
m m m m m m m m  
SIG  
SIG Actual Value  
SIG Stable Value  
Feature Control Channel Signaling Channel  
m : Monitor channel bits, these bits are treated by the monitor/feature control handler  
: Inactive sub. time-slot, in downstream direction these bits are tristated (OMDR : COS = 0) or set to logical 1(OMDR : COS = 1)  
-
C/I : Command/Indication channel, these bits are exchanged between the CFI in/output and the CM data field. A change of  
the C/I bits in upstream direction causes an interrupt (ISTA : SFI). The address of the change is stored in the CIFIFO  
D : D channel, these D channel bits are transparently switched to and from the PCM interface.  
SIG : Signaling Channel, these bits are exchanged between the CFI in/output and the CM data field. The SIG value which  
actual value was present in the last frame is stored as the actual value in the even address CM location. The stable value is updated  
stable value if a valid change in the actual value has been detected according to the last look algorithm. A change of the SIG stable  
value in upstream direction causes an interrupt (ISTA : CFI).The address of the change is stored in the CIFIFO.  
ITD09544  
Figure 19  
Pre-processed Channel Codes  
Semiconductor Group  
40  
 
PEB 2055  
PEF 2055  
Operational Description  
Synchronous Transfer  
For two channels, all switching paths of figure 18 can also be realized using  
Synchronous Transfer. The working principle is that the µP specifies an input time slot  
(source) and an output time slot (destination). Both source and destination time slots can  
be selected independently from each other at either the PCM or CFI interfaces. In each  
frame, the EPIC first transfers the serial data from the source time slot to an internal data  
register from where it can be read and if required overwritten or modified by the µP. This  
data is then fed forward to the destination time slot.  
Chapter 5.7 provides examples of such transfers.  
3.4.4  
Special Functions  
Hardware Timer  
The EPIC-1 provides a hardware timer which continuously interrupts the µP after  
programmable time periods. The timer period can be selected in the range of 250 µs up  
to 32 ms in multiples of 250 µs. Beside the interrupt generation, the timer can also be  
used to determine the last look period for 6- and 8-bit signaling channels on IOM-2 and  
SLD interfaces and for the generation of an FSC multiframe signal (see chapter 5.8.1).  
Power and Clock Supply Supervision  
The Connection Memory CM is supervised to data falsification due to clock or power  
failure. If such an inappropriate clocking or power failure occurs, the µP is requested to  
reinitialize the device.  
Semiconductor Group  
41  
PEB 2055  
PEF 2055  
Operational Description  
3.5  
Initialization Procedure  
For proper initialization of the EPIC the following procedure is recommended:  
3.5.1  
Hardware Reset  
A reset pulse can be applied at the RES pin for at least 4 PDC clock cycles. The reset  
pulse sets all registers to their reset values (refer to chapter 4.1).  
Note: In this state DCL and FSC do not provide any clock signals.  
3.5.2  
EPIC® Initialization  
3.5.2.1 Register Initialization  
The PCM and CFI configuration registers (PMOD, PBNR, , CMD1, CMD2, ) have to  
be programmed to the values required for the application. The correct setting of the PCM  
and CFI registers is important in order to obtain a reference clock (RCL) which is  
consistent with the externally applied clock signals.  
The state of the operation mode (OMDR:OMS1..0 bits) does not matter for this  
programming step.  
PMOD =  
PBNR =  
POFD =  
POFU =  
PCSR =  
CMD1 =  
CMD2 =  
CBNR =  
CTAR =  
CBSR =  
CSCR =  
PCM-mode, timing characteristics, etc.  
Number of bits per PCM-frame  
PCM-offset downstream  
PCM-offset upstream  
PCM-timing  
CFI-mode, timing characteristics, etc.  
CFI-timing  
Number of bits per CFI-frame  
CFI-offset (time slots)  
CFI-offset (bits)  
CFI-sub channel positions  
3.5.2.2 Control Memory Reset  
Since the hardware reset does not affect the EPIC memories (Control and Data  
Memories), it is mandatory to perform a “software reset” of the CM. The CM code  
“0000”B (unassigned channel) should be written to each location of the CM. The data  
written to the CM data field is then don’t care, e.g. FFH.  
OMDR:OMS1..0 must be to “00”B for this procedure (reset value).  
MADR =  
MACR =  
FFH  
70H  
Wait for STAR:MAC = “0”  
The resetting of the complete CM takes 256 RCL clock cycles. During this time, the  
STAR:MAC-bit is set to logical “1”.  
Semiconductor Group  
42  
PEB 2055  
PEF 2055  
Operational Description  
3.5.2.3 Initialization of Pre-processed Channels  
After the CM reset, all CFI time slots are unassigned. If the CFI is used as a plain PCM  
interface, i.e. containing only switched channels (B channels), the initialization steps  
below are not required. The initialization of pre-processed channels applies only to IOM  
or SLD applications.  
An IOM or SLD “channel” consists of four consecutive time slots. The first two time slots,  
the B channels need not be initialized since they are already set to unassigned channels  
by the CM reset command. Later, in the application phase of the software, the B  
channels can be dynamically switched according to system requirements. The last two  
time slots of such an IOM or SLD channel, the pre-processed channels must be  
initialized for the desired functionality. There are four options that can be selected:  
Table 2  
Pre-processed Channel Options at the CFI  
Even CFI Time Slot  
Odd CFI Time Slot  
Main  
Application  
Monitor/feature control channel 4-bit C/I channel, D channel not  
IOM-1 or IOM-2  
digital subscriber  
switched (decentral D channel  
handling)  
Monitor/feature control channel 4-bit C/I channel, D channel  
IOM-1 or IOM-2  
switched (central D ch. handling) digital subscriber  
Monitor/feature control channel 6-bit SIG channel  
IOM-2, analog  
subscriber  
Monitor/feature control channel 8-bit SIG/channel  
SLD, analog  
subscriber  
Also refer to figure 19.  
Example  
In CFI-mode 0 all four CFI-ports shall be initialized as IOM-2 ports with a 4-bit C/I-field  
and decentral D channel handling.  
CFI time slots 0, 1, 4, 5, 8, 9 28, 29 of each port are B channels and need not to be  
initialized.  
CFI time slots 2, 3, 6, 7, 10, 11, …, 30, 31 of each port are pre-processed channels and  
need to be initialized:  
Semiconductor Group  
43  
PEB 2055  
PEF 2055  
Operational Description  
CFI-port 0, time slot 2 (even), downstream  
MADR = FFH ; the C/I-value “1111” will be transmitted upon CFI activation  
MAAR = 08H ; addresses ts 2 down  
MACR = 78H ; CM-code “1000”  
Wait for STAR:MAC = 0  
CFI-port 0, time slot 3 (odd), downstream  
MADR = FFH ; don’t care  
MAAR = 09H ; addresses ts 3 down  
MACR = 7BH ; CM-code “1011”  
Wait for STAR:MAC = 0  
CFI-port 0, time slot 2 (even), upstream  
MADR = FFH ; the C/I-value “1111” is expected upon CFI activation  
MAAR = 88H ; address ts 2 up  
MACR = 78H ; CM-code “1000”  
Wait for STAR:MAC = 0  
CFI-port 0, time slot 3 (odd), upstream  
MADR = FFH ; don’t care  
MAAR = 89H ; address ts 3 up  
MACR = 70H ; CM-code “0000”  
Wait for STAR:MAC = 0  
Repeat the above programming steps for the remaining CFI ports and time slots.  
This procedure can be speeded up by selecting the CM initialization mode  
(OMDR:OMS1..0 = 10). If this selection is made, the access time to a single memory  
location is reduced to 2.5 RCL cycles. The complete initialization time for 32 IOM-2  
channels is then reduced to 128 × 0.61 µs = 78 µs.  
Semiconductor Group  
44  
PEB 2055  
PEF 2055  
Operational Description  
3.5.2.4 Initialization of the Upstream Data Memory (DM) Tristate Field  
For each PCM time slot the tristate field defines whether the contents of the DM data  
field are to be transmitted (low impedance), or whether the PCM time slot shall be set to  
high impedance. The contents of the tristate field is not modified by a hardware reset. In  
order to have all PCM time slots set to high impedance upon the activation of the PCM-  
interface, each location of the tristate field must be loaded with the value ’0000’. For this  
purpose, the ‘tristate reset’ command can be used:  
OMDR = C0H ; OMS1..0 = 11, normal mode  
MADR = 00H ; code field value“0000”B  
MACR = 68H ; MOC-code to initialize all tristate locations (1101B)  
Wait for STAR:MAC = 0  
The initialization of the complete tristate field takes 1035 RCL cycles.  
Note: It is also possible to program the value “0000” to the tristate field in order to have  
all time slots switched to low impedance upon the activation of the PCM interface.  
Note: While OMDR:PSB = 0, all PCM-output drivers are set to high impedance,  
regardless of the values written to the tristate field.  
3.5.3  
Activation of the PCM and CFI Interfaces  
With the EPIC configured to the system requirements, the PCM and CFI interface can  
be switched to the operational mode.  
The OMDR:OMS1..0 bits must be set (if this has not already be done) to the normal  
operation mode (OMS1..0 = 11). When doing this, the PCM framing interrupt (ISTA:PFI)  
will be enabled. If the applied clock and framing signals are in accordance with the  
values programmed to the PCM-registers, the PFI interrupt will be generated (if not  
masked). When reading the status register, the STAR:PSS-bit will be set to logical 1.  
To enable the PCM-output drivers set OMDR:PSB = 1. The CFI interface is activated by  
programming OMDR:CSB = 1. This enables the output clock and framing signals (DCL  
and FSC), if these have been programmed as outputs. It also enables the CFI output  
drivers. The output driver type can be selected between “open drain” and “tristate” with  
the OMDR:COS bit.  
Example: Activation of the EPIC for a typical IOM-2 application:  
OMDR = EEH;  
Normal operation mode (OMS1..0 = 11)  
PCM interface active (PSB = 1)  
PCM test loop disabled (PTL = 0)  
CFI output drivers: open drain (COS = 1)  
Monitor handshake protocol selected (MFPS = 1)  
CFI active (CSB = 1)  
Access to EPIC registers via address pins A3..A0, used in  
demultiplexed mode only, normal operation (RBS = 0)  
Semiconductor Group  
45  
PEB 2055  
PEF 2055  
Detailed Register Description  
4
Detailed Register Description  
Register Address Arrangement  
4.1  
Group  
Reg.  
Name  
Access Address Address  
Reset Comment  
Value  
Refer to  
page  
mux  
demux  
AD7..0  
OMDR:RBS/  
A3..0  
PMOD  
PBNR  
POFD  
RD/WR  
RD/WR  
RD/WR  
20  
22  
24  
1/0  
1/1  
1/2  
00  
H
PCM-mode reg.  
48  
50  
50  
H
H
H
H
H
H
FF  
PCM-bit number reg.  
H
H
00  
PCM-offset downstream  
reg.  
PCM  
interface  
POFU  
PCSR  
PICM  
RD/WR  
RD/WR  
RD  
26  
28  
1/3  
1/4  
1/5  
00  
00  
PCM-offset upstream reg. 51  
H
H
H
H
H
H
H
H
PCM-clock shift reg.  
51  
52  
2A  
xx  
PCM-input comparison  
mismatch reg.  
H
CMD1  
CMD2  
CBNR  
CTAR  
RD/WR  
RD/WR  
RD/WR  
RD/WR  
2C  
1/6  
1/7  
1/8  
1/9  
00  
00  
CFI-mode reg. 1  
CFI-mode reg. 2  
CFI-bit number reg.  
53  
55  
58  
58  
H
H
H
H
H
H
H
H
H
2E  
H
30  
32  
FF  
H
H
CFI  
interface  
00  
CFI time slot adjustment  
reg.  
CBSR  
CSCR  
MACR  
RD/WR  
RD/WR  
RD/WR  
34  
36  
00  
1/A  
1/B  
00  
00  
CFI-bit shift reg.  
59  
60  
61  
H
H
H
H
H
H
H
H
H
CFI-subchannel reg.  
0/0  
0/1  
xx  
Memory access control  
reg.  
Memory  
access  
MAAR  
RD/WR  
02  
xx  
Memory access address  
reg.  
65  
H
H
H
MADR  
STDA  
RD/WR  
RD/WR  
04  
06  
0/2  
0/3  
xx  
xx  
Memory access data reg.  
66  
67  
H
H
H
H
H
Synchron transfer data  
reg. A  
H
STDB  
SARA  
SARB  
SAXA  
SAXB  
STCR  
RD/WR  
RD/WR  
RD/WR  
RD/WR  
RD/WR  
RD/WR  
08  
0/4  
0/5  
0/6  
0/7  
0/8  
0/9  
xx  
xx  
xx  
xx  
xx  
Synchron transfer data  
reg. B  
67  
68  
69  
H
H
H
H
H
H
H
H
H
H
H
H
0A  
Synchron transfer receive  
address reg. A  
H
Synchro-  
nous  
transfer  
0C  
Synchron transfer receive  
address reg. B  
H
H
H
H
0E  
Synchron transfer transmit 69  
address reg. A  
10  
12  
Synchron transfer transmit 70  
address reg. B  
00xxxx Synchron transfer control  
xx reg.  
70  
Semiconductor Group  
46  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.1  
Register Address Arrangement (cont’d)  
Group  
Reg.  
Name  
Access Address Address  
Reset Comment  
Value  
Refer to  
page  
mux  
demux  
AD7..0  
OMDR:RBS/  
A3..0  
MFAIR  
RD  
14  
14  
0/A  
0/A  
0/B  
00  
00  
MF-channel active  
indication reg.  
71  
72  
H
H
H
H
H
H
H
H
Monitor/  
feature  
control  
MFSAR  
WR  
MF-channel subscriber  
address reg.  
MFFIFO  
CIFIFO  
RD/WR  
RD  
16  
18  
xx  
MF-channel FIFO  
73  
73  
H
0/C  
0xxxxx Signaling channel FIFO  
xx  
H
H
TIMR  
WR  
18  
0/C  
0/D  
0/D  
00  
05  
00  
00  
00  
00  
Timer reg.  
74  
75  
76  
78  
79  
80  
H
H
H
H
H
H
H
H
H
H
H
H
H
STAR  
CMDR  
ISTA  
RD  
1A  
1A  
Status register EPIC  
Command reg. EPIC  
Interrupt status EPIC-1  
Mask register EPIC-1  
Operation mode reg.  
H
H
WR  
Status/  
control  
RD  
1C  
1C  
0/E  
0/E  
H
H
MASK  
OMDR  
WR  
RD/WR  
1E  
3E  
x/F  
1/D  
H
H
VNSR  
RD/WR  
3A  
00  
Version number status  
register  
82  
H
H
H
Semiconductor Group  
47  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2  
Detailed Register Description  
PCM Interface Registers  
4.2.1  
4.2.1.1 PCM-Mode Register (PMOD)  
Access in demultiplexed µP-interface mode:  
read/write  
read/write  
address: 0H,  
OMDR:RBS = 1  
address: 20H  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
PMD1  
PMD0  
PCR  
PSM  
AIS1  
AIS0  
AIC1  
AIC0  
PMD1..0 PCM Mode. Defines the actual number of PCM ports, the data rate range and  
the data rate stepping.  
PMD1..0  
PCM  
Mode  
Port  
Count  
Data Rate  
[kbit/s]  
Data Rate  
Stepping  
[kbit/s]  
min.  
max.  
00  
01  
10  
0
1
2
4
2
1
256  
512  
1024  
2048  
4096  
8192  
256  
512  
1024  
The actual selection of physical pins is described below (AIS1/0).  
PCR  
PCM Clock Rate.  
0single clock rate, data rate is identical with the clock frequency supplied  
on pin PDC.  
1double clock rate, data rate is half the clock frequency supplied on pin  
PDC.  
Note: Only single clock rate is allowed in PCM-mode 2!  
PSM  
PCM Synchronization Mode.  
A rising edge on PFS synchronizes the PCM frame. PFS is not evaluated  
directly but is sampled with PDC.  
0the external PFS is evaluated with the falling edge of PDC. The internal  
PFS (internal frame start) occurs with the next rising edge of PDC.  
1the external PFS is evaluated with the rising edge of PDC. The internal  
PFS (internal frame start) occurs with this rising edge of PDC.  
Semiconductor Group  
48  
PEB 2055  
PEF 2055  
Detailed Register Description  
AIS1..0  
Alternative Input Selection.  
These bits determine the relationship between the physical pins and the  
logical port numbers. The logical port numbers are used when programming  
the switching functions.  
Note: In PCM-mode 0 these bits may not be set!  
PCM  
Mode  
Port 0  
Port 1  
Port 2  
Port 3  
TxD3 TSC3  
RxD0 TxD0 TSC0 RxD1  
TxD1 TSC1 RxD2  
TxD2 TSC2 RxD3  
0
1
IN0  
OUT0 val0  
OUT0 val0  
IN1  
OUT1 val1  
tristate AIS0  
IN2  
OUT2 val2  
OUT1 val1  
IN3  
OUT3 val3  
tristate AIS1  
IN0  
IN0  
IN1  
IN1  
(AIS0=1)  
(AIS0=0)  
(AIS1=1)  
(AIS1=0)  
2
not  
OUT val not active tristate AIS0  
IN  
undef. undef.  
IN  
tristate AIS1  
active  
(AIS1=1)  
(AIS1=0)  
AIC1  
Alternate Input Comparison 1.  
0…input comparison of port 2 and 3 is disabled  
1…the inputs of port 2 and 3 are compared  
AIC0  
Alternate Input Comparison 0.  
0…input comparison of port 0 and 1 is disabled  
1…the inputs of port 0 and 1 are compared  
Note: The comparison function is operational in all PCM modes; however, a redundant  
PCM line which can be switched over to by means of the PMOD:AIS bits is only  
available in PCM modes 1 and 2.  
Semiconductor Group  
49  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.1.2 Bit Number per PCM-Frame (PBNR)  
Access in demultiplexed µP-interface mode:  
read/write  
read/write  
address: 1H  
OMDR:RBS = 1  
address: 22H  
Access in multiplexed µP-interface mode:  
Reset value: FFH  
bit 7  
bit 0  
BNF7  
BNF6  
BNF5  
BNF4  
BNF3  
BNF2  
BNF1  
BNF0  
BNF7..0 Bit Number per PCM Frame.  
PCM-mode 0: BNF7..0 = number of bits – 1  
PCM-mode 1: BNF7..0 = (number of bits – 2) / 2  
PCM-mode 2: BNF7..0 = (number of bits – 4) / 4  
The value programmed in PBNR is also used to check the PFS period.  
4.2.1.3 PCM-Offset Downstream Register (POFD)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 2H  
OMDR:RBS = 1  
address: 24H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: 00H  
bit 7  
bit 0  
OFD9  
OFD8  
OFD7  
OFD6  
OFD5  
OFD4  
OFD3  
OFD2  
OFD9..2 Offset Downstream bit 9…2.  
These bits together with PCSR:OFD1..0 determine the offset of the PCM  
frame in downstream direction. The following formulas apply for calculating  
the required register value. BND is the bit number in downstream direction  
marked by the rising internal PFS edge. BPF denotes the actual number of  
bits constituting a frame.  
PCM mode 0:  
PCM mode 1:  
PCM mode 2:  
OFD9..2 = modBPF (BND – 17 + BPF)  
PCSR:OFD1..0 = 0  
OFD9..1 = modBPF (BND – 33 + BPF)  
PCSR: PFD0 = 0  
OFD9..0 = modBPF (BND – 65 + BPF)  
Semiconductor Group  
50  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.1.4 PCM-Offset Upstream Register (POFU)  
Access in demultiplexed µP-interface mode:  
read/write  
read/write  
address: 3H  
OMDR:RBS = 1  
address: 26H  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
OFU9  
OFU8  
OFU7  
OFU6  
OFU5  
OFU4  
OFU3  
OFU2  
OFU9..2 Offset Upstream bit 9…2.  
These bits together with PCSR:OFU1..0 determine the offset of the PCM  
frame in upstream direction. The following formulas apply for calculating the  
required register value. BNU is the bit number in upstream direction marked  
by the rising internal PFS-edge.  
PCM mode 0:  
PCM mode 1:  
PCM mode 2:  
OFU9..2 = modBPF (BNU + 23)  
PCSR:OFU1..0 = 00  
OFU9..1 = modBPF (BNU + 47)  
PCSR:OFU0 = 0  
OFU9..0 = modBPF (BNU + 95)  
4.2.1.5 PCM-Clock Shift Register (PCSR)  
Access in demultiplexed µP-interface mode:  
read/write  
read/write  
address: 4H  
OMDR:RBS = 1  
address: 28H  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
0
OFD1  
OFD0  
DRE  
0
OFU1  
OFU0  
URE  
OFD1..0 Offset Downstream bits 1…0, see POFD register.  
DRE Downstream Rising Edge.  
0…the PCM-data is sampled with the falling edge of PDC  
1…the PCM-data is sampled with the rising edge of PDC  
OFU1..0 Offset Upstream bits 1…0, see POFU register.  
URE  
Upstream Rising Edge.  
0…the PCM-data is transmitted with the falling edge of PDC  
1…the PCM-data is transmitted with the rising edge of PDC  
Semiconductor Group  
51  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.1.6 PCM-Input Comparison Mismatch (PICM)  
Access in demultiplexed µP-interface mode:  
read  
address: 5H  
OMDR:RBS = 1  
Access in multiplexed µP-interface mode:  
read/write  
address: 2AH  
Reset value: xxH  
bit 7  
bit 0  
TSN0  
IPN  
TSN6  
TSN5  
TSN4  
TSN3  
TSN2  
TSN1  
IPN  
Input Pair Number.  
This bit denotes the pair of ports, where a bit mismatch occurred.  
0…mismatch between ports 0 and 1  
1…mismatch between ports 2 and 3  
TSN6..0 Time Slot Number.  
When a bit mismatch occurred these bits identify the affected bit position.  
PCM Mode  
Time Slot  
Bit Identification  
Identification  
0
TSN6…TSN2 + 2  
TSN1,0= 00: bits 6,7  
01: bits 4,5  
10: bits 2,3  
11: bits 0,1  
1
2
TSN6…TSN1 + 4  
TSN6…TSN0 + 8  
TSN0=  
0: bits 4…7  
1: bits 0…3  
Semiconductor Group  
52  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.2  
Configurable Interface Registers  
4.2.2.1 Configurable Interface Mode Register 1 (CMD1)  
Access in demultiplexed µP-interface mode:  
read/write  
read/write  
address: 6H  
OMDR:RBS = 1  
address: 2CH  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
CSS  
CSM  
CSP1  
CSP0  
CMD1  
CMD0  
CIS1  
CIS0  
CSS  
Clock Source Selection.  
0…PDC and PFS are used as clock and framing source for the CFI. Clock  
and framing signals derived from these sources are output on DCL and  
FSC.  
1…DCL and FSC are selected as clock and framing source for the CFI.  
CSM  
CFI-Synchronization Mode.  
The rising FSC edge synchronizes the CFI-frame.  
0…FSC is evaluated with every falling edge of DCL.  
1…FSC is evaluated with every rising edge of DCL.  
Note: If CSS = 0 is selected, CSM and PMOD:PSM must be programmed  
identical.  
CSP1..0 Clock Source Prescaler 1,0.  
The clock source frequency is divided according to the following table to  
obtain the CFI reference clock CRCL.  
CSP1,0  
00  
Prescaler Divisor  
2
01  
1.5  
10  
1
11  
not allowed  
Semiconductor Group  
53  
PEB 2055  
PEF 2055  
Detailed Register Description  
CMD1..0 CFI Mode1,0.  
Defines the actual number and configuration of the CFI ports.  
CMD1..0 CFI  
Number  
CFI Data Rate Min. Required Necessary  
[kbit/s] CFI Data Rate Reference  
DCL-Output  
Frequencies  
Mode of  
Logical  
Ports  
[kbit/s]  
Relative to  
PCM-Data Rate  
Clock (RCL) CMD1:CSS0 = 0  
min.  
max.  
00  
01  
0
1
4 DU  
(0..3)  
128  
128  
128  
2048  
4096  
32N/3  
2xDR  
DR  
DR, 2xDR1)  
DR  
2 DU  
(0..1)  
64N/3  
10  
11  
2
3
1 DU  
8192  
1024  
64N/3  
16N/3  
0.5xDR  
4xDR  
DR  
8 bi (0..7) 128  
DR, 2xDR  
where N = number of time slots in a PCM frame  
CFI Alternative Input Selection.  
CIS1..0  
In CFI mode 1 and 2 CIS1..0 controls the assignment between logical and  
physical receive pins. In CFI mode 0 and 3 CIS1,0 should be set to 0.  
Port 0  
DD0  
Port 1  
DD1  
Port 2  
DD2  
Port 3  
DD3  
CFI  
Mode  
DU0  
DU1  
DU2  
DU3  
0
1
IN0  
OUT0  
OUT0  
IN1  
OUT1  
OUT1  
IN2  
OUT2  
tristate  
IN3  
OUT3  
tristate  
IN0  
IN1  
IN0  
IN1  
CIS0 = 0  
CIS1 = 0  
CIS0 = 1  
CIS1 = 1  
2
3
IN  
CIS0 = 0  
OUT  
I/O0  
not active tristate  
I/O5 I/O1  
IN  
CIS0 = 1  
tristate  
I/O2  
not active tristate  
I/O7 I/O3  
I/O4  
I/O6  
Semiconductor Group  
54  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.2.2 Configurable Interface Mode Register 2 (CMD2)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 7H  
OMDR:RBS = 1  
address: 2EH  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: 00H  
bit 7  
bit 0  
FC2  
FC1  
FC0  
COC  
CXF  
CRR  
CBN9  
CBN8  
FC2..0  
Framing output Control.  
Given that CMD1:CSS = 0, these bits determine the position of the FSC  
pulse relative to the CFI frame, as well as the type of FSC pulse generated.  
The position and width of the FSC signal with respect to the CFI frame can  
be found in the following two figures 20 and 21.  
Semiconductor Group  
55  
PEB 2055  
PEF 2055  
Detailed Register Description  
CFI  
Frame  
Last Time-Slot of a Frame  
Time-Slot 0  
RCL  
Conditions:  
CFI Mode 0; CMD2 : COC = 1  
CFI Modes 1, 2; CMD2 : COC = 0  
DCL  
CFI Mode 0; CMD2 : COC = 0  
CFI Mode 3; CMD2 : COC = 1  
DCL  
DCL  
CFI Mode 3; COC = 0  
FSC  
FSC  
CMD2 : FC2...0 = 011 (FC mode 3)  
CMD2 : FC2...0 = 010 (FC mode 2)  
FSC  
FSC  
FSC  
CMD2 : FC2...0 = 000 (FC mode 0)  
CMD2 : FC2...0 = 001 (FC mode 1)  
CMD2 : FC2...0 = 010 (FC mode 6)  
ITD05851  
Figure 20  
Position of the FSC Signal for FC Modes 0, 1, 2, 3 and 6  
Time-Slot  
CFI  
0
1
2
3
4
5
Frame  
Conditions:  
FSC  
FSC  
CMD2 : FC2...0 = 110 (FC mode 6)  
CMD2 : FC2...0 = 100 (FC mode 4)  
RCL  
ITD05852  
Figure 21  
Position of the FSC Signal for FC Modes 4 and 6  
Semiconductor Group  
56  
PEB 2055  
PEF 2055  
Detailed Register Description  
Application examples:  
FC2  
FC1  
FC0  
FC-Mode Main Applications  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
2
3
4
5
6
7
IOM-1 multiplexed (burst) mode  
general purpose  
general purpose  
general purpose  
2 ISAC-S per SLD-port  
reserved  
IOM-2 or SLD modes  
software timed multiplexed applications  
For further details on the framing output control please refer to chapter 5.2.2.3.  
COC  
CFI Output Clock rate.  
0…the frequency of DCL is identical to the CFI data rate (all CFI modes),  
1…the frequency of DCL is twice the CFI data rate (CFI modes 0 and 3 only!)  
Note:Applies only if CMD1:CSS = 0.  
CXF  
CRR  
CFI Transmit on Falling edge.  
0…the data is transmitted with the rising CRCL edge,  
1…the data is transmitted with the falling CRCL edge.  
CFI Receive on Rising edge.  
0…the data is received with the falling CRCL edge,  
1…the data is received with the rising CRCL edge.  
Note:CRR must be set to 0 in CFI-mode 3.  
CBN9..8 CFI Bit Number 9..8  
these bits, together with the CBNR:CBN7..0, hold the number of bits per CFI  
frame.  
Semiconductor Group  
57  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.2.3 Configurable Interface Bit Number Register (CBNR)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 8H  
OMDR:RBS = 1  
address: 30H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: FFH  
bit 7  
bit 0  
CBN7  
CBN6  
CBN5  
CBN4  
CBN3  
CBN2  
CBN1  
CBN0  
CBN7..0 CFI Bit Number 7..0.  
The number of bits that constitute a CFI frame must be programmed to  
CMD2, CBNR:CBN9..0 as indicated below.  
CBN9..0 = number of bits 1  
For a 8-kHz frame structure, the number of bits per frame can be derived  
from the data rate by division with 8000.  
4.2.2.4 Configurable Interface Time Slot Adjustment Register (CTAR)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 9H  
OMDR:RBS = 1  
address: 32H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: 00H  
bit 7  
bit 0  
0
TSN6  
TSN5  
TSN4  
TSN3  
TSN2  
TSN1  
TSN0  
TSN6..0 Time Slot Number.  
The CFI framing signal (PFS if CMD1:CSS = 0 or FSC if CMD1:CSS = 1)  
marks the CFI time slot called TSN according to the following formula:  
TSN6..0 = TSN + 2  
E.g.: If the framing signal is to mark time slot 0 (bit 7), CTAR must be set to  
02H (CBSR to 20H).  
Note: If CMD1:CSS = 0, the CFI frame will be shifted - together with the FSC output  
signal - with respect to PFS. The position of the CFI frame relative to the FSC  
output signal is not affected by these settings, but is instead determined by  
CMD2:FC2..0.  
If CMD1:CSS = 1, the CFI frame will be shifted with respect to the FSC-input  
signal.  
Semiconductor Group  
58  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.2.5 Configurable Interface Bit Shift Register (CBSR)  
Access in demultiplexed µP-interface mode:  
read/write  
address: AH  
OMDR:RBS = 1  
address: 34H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: 00H  
bit 7  
bit 0  
0
CDS2  
CDS1  
CDS0  
CUS3  
CUS2  
CUS1  
CUS0  
CDS2..0 CFI Downstream bit Shift 2..0.  
From the zero offset bit position (CBSR = 20H) the CFI frame (downstream  
and upstream) can be shifted by up to 6 bits to the left (within the time slot  
number TSN programmed in CTAR) and by up to 2 bits to the right (within  
the previous time slot TSN – 1) by programming the CBSR:CDS2..0 bits:  
CBSR:CDS2..0  
Time Slot No.  
Bit No.  
000  
TSN – 1  
TSN – 1  
TSN  
1
001  
010  
0
7
011  
100  
101  
110  
111  
6
5
4
3
2
TSN  
TSN  
TSN  
TSN  
TSN  
The bit shift programmed to CBSR:CDS2..0 affects both the upstream and  
downstream frame position in the same way.  
CUS3..0 CFI Upstream bit Shift 3..0.  
These bits shift the upstream CFI frame relative to the downstream frame by  
up to 15 bits. For CUS3..0 = 0000, the upstream frame is aligned with the  
downstream frame (no bit shift).  
Semiconductor Group  
59  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.2.6 Configurable Interface Subchannel Register (CSCR)  
Access in demultiplexed µP-interface mode:  
read/write  
address: BH  
OMDR:RBS = 1  
address: 36H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: 00H  
bit 7  
bit 0  
SC31  
SC30  
SC21  
SC20  
SC11  
SC10  
SC01  
SC00  
SC#1..#0 CFI Subchannel Control for logical port #.  
The subchannel control bits SC#1..SC#0 specify separately for each logical  
port the bit positions to be exchanged with the data memory (DM) when a  
connection with a channel bandwidth as defined by the CM-code has been  
established:  
SC#1  
SC#0  
Bit Positions for CFI Subchannels  
having a Bandwidth of  
64 kbit/s  
32 kbit/s  
16 kbit/s  
0
0
1
1
0
1
0
1
7..0  
7..0  
7..0  
7..0  
7..4  
3..0  
7..4  
3..0  
7..6  
5..4  
3..2  
1..0  
Note: In CFI-mode 1: SC21 = SC01; SC20 = SC00; SC31 = SC11; SC30 = SC10  
In CFI-mode 2: SC31 = SC21 = SC11 = SC01; SC30 = SC20 = SC10 = SC00  
In CFI-mode 3: SC0x control ports 0 and 4; SC1x control ports 1 and 5;  
SC2x control ports 2 and 6; SC3x control ports 3 and 7  
Semiconductor Group  
60  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.3  
Memory Access Registers  
4.2.3.1 Memory Access Control Register (MACR)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 0H  
OMDR:RBS = 0  
address: 00H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: xxH  
bit 7  
bit 0  
RWS  
MOC3  
MOC2  
MOC1  
MOC0  
CMC3  
CMC2  
CMC1  
CMC0  
With the MACR the µP selects the type of memory (CM or DM), the type of field (data or  
code) and the access mode (read or write) of the register access. When writing to the  
control memory code field, MACR also contains the 4 bit code (CMC3..0) defining the  
function of the addressed CFI time slot.  
RWS  
Read/Write Select.  
0…write operation on control or data memories  
1…read operation on control or data memories  
MOC3..0 Memory Operation Code.  
CMC3..0 Control Memory Code.  
These bits determine the type and destination of the memory operation as  
shown below.  
Note: Prior to a new access to any memory location (i.e. writing to MACR) the  
STAR:MAC bit must be polled for “0”.  
Semiconductor Group  
61  
PEB 2055  
PEF 2055  
Detailed Register Description  
1. Writing data to the upstream DM data field (e.g. PCM idle code).  
Reading data from the upstream or downstream DM data field.  
MACR:  
RWS  
MOC3  
MOC2  
MOC1  
MOC0  
0
0
0
MOC3..0 defines the bandwidth and the position of the subchannel as shown below:  
MOC3..0  
Transferred Bits  
Channel Bandwidth  
0000  
0001  
0011  
0010  
0111  
0110  
0101  
0100  
bits 7..0  
bits 7..4  
bits 3..0  
bits 7..6  
bits 5..4  
bits 3..2  
bits 1..0  
64 kbit/s  
32 kbit/s  
32 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
Note: When reading a DM data field location, all 8 bits are read regardless of the  
bandwidth selected by the MOC bits.  
2. Writing to the upstream DM code (tristate) field.  
Control-reading the upstream DM code (tristate).  
MACR:  
RWS  
MOC3  
MOC2  
MOC1  
MOC0  
0
0
0
MOC = 1100  
MOC = 1101  
Read/write tristate info from/to single PCM time slot  
Write tristate info to all PCM time slots  
Note: The tristate field is exchanged with the 4 least significant bits (LSBs) of the MADR.  
3. Writing data to the upstream or downstream CM data field (e.g. signaling code).  
Reading data from the upstream or downstream CM data field.  
MACR:  
RWS  
1
0
0
1
0
0
0
Semiconductor Group  
62  
 
PEB 2055  
PEF 2055  
Detailed Register Description  
4. Writing data to the upstream or downstream CM data and code field  
(e.g. switching a CFI to/from PCM connection).  
MACR:  
0
1
1
1
CMC3  
CMC2  
CMC1  
CMC0  
The 4-bit code field of the control memory (CM) defines the functionality of a  
CFI time slot and thus the meaning of the corresponding data field. This 4-bit  
code, written to the MACR:CMC3..0 bit positions, will be transferred to the  
CM code field. The 8-bit MADR value is at the same time transferred to the  
CM data field. There are codes for switching applications, pre-processed  
applications and for direct µP access applications, as shown below:  
a) Switching Applications  
CMC = 0000  
CMC = 0001  
CMC = 0010  
CMC = 0011  
CMC = 0100  
CMC = 0101  
CMC = 0110  
CMC = 0111  
Unassigned channel (e.g. cancelling an assigned channel)  
Bandwidth 64 kbit/s PCM time slot bits transferred: 7..0  
Bandwidth 32 kbit/s PCM time slot bits transferred: 3..0  
Bandwidth 32 kbit/s PCM time slot bits transferred: 7..4  
Bandwidth 16 kbit/s PCM time slot bits transferred: 1..0  
Bandwidth 16 kbit/s PCM time slot bits transferred: 3..2  
Bandwidth 16 kbit/s PCM time slot bits transferred: 5..4  
Bandwidth 16 kbit/s PCM time slot bits transferred: 7..6  
Note: The corresponding CFI time slot bits to be transferred are chosen in the  
CSCR-register.  
Semiconductor Group  
63  
PEB 2055  
PEF 2055  
Detailed Register Description  
b) Pre-processed Applications  
Downstream:  
Application  
Even CM Address  
Odd CM Address  
Decentral D channel handling  
Central D channel handling  
CMC = 1000  
CMC = 1010  
CMC = 1011  
CMC = PCM code for a  
2-bit subtime slot  
6-bit Signaling (e.g. analog IOM)  
8-bit Signaling (e.g. SLD)  
CMC = 1010  
CMC = 1010  
CMC = 1011  
CMC = 1011  
Upstream:  
Application  
Even CM Address  
CMC = 1000  
Odd CM Address  
Decentral D channel handling  
Central D channel handling  
CMC = 0000  
CMC = 1000  
CMC = PCM code for a  
2-bit subtime slot  
6-bit Signaling (e.g. analog IOM)  
8-bit Signaling (e.g. SLD)  
CMC = 1010  
CMC = 1011  
CMC = 1010  
CMC = 1011  
c) µP-access Applications  
MACR:  
0
1
1
1
1
0
0
1
Setting CMC = 1001, initializes the corresponding CFI time slot to be  
accessed by the µP. Concurrently, the datum in MADR is written (as 8-bit  
CFI-idle code) to the CM data field. The content of the CM data field is directly  
exchanged with the corresponding time slot.  
Note that once the CM code field has been initialized, the CM data field can  
be written and read as described in subsection 3.  
5. Control-reading the upstream or downstream CM code.  
MACR:  
1
1
1
1
0
0
0
0
The CM code can then be read out of the 4 LSBs of the MADR register.  
Semiconductor Group  
64  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.3.2 Memory Access Address Register (MAAR)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 1H  
OMDR:RBS = 0  
address: 02H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: xxH  
bit 7  
bit 0  
U/D  
MA6  
MA5  
MA4  
MA3  
MA2  
MA1  
MA0  
The Memory Access Address Register MAAR specifies the address of the memory  
access. This address encodes a CFI time slot for control memory (CM) and a PCM time  
slot for data memory (DM) accesses. Bit 7 of MAAR (U/D bit) selects between upstream  
and downstream memory blocks. Bits MA6..0 encode the CFI or PCM port and time slot  
number as in the following tables:  
Table 3  
Time Slot Encoding for Data Memory Accesses  
Data Memory Address  
PCM-mode 0  
PCM-mode 1,3  
PCM-mode 2  
bit U/D  
bits MA6..MA3, MA0  
bits MA2..MA1  
Direction selection  
Time slot selection  
Logical PCM port number  
bit U/D  
Direction selection  
bits MA6..MA3, MA1, MA0 Time slot selection  
bit MA2  
Logical PCM port number  
bit U/D  
bits MA6..MA0  
Direction selection  
Time slot selection  
Semiconductor Group  
65  
 
PEB 2055  
PEF 2055  
Detailed Register Description  
Table 4  
Time Slot Encoding for Control Memory Accesses  
Control Memory Address  
CFI-mode 0  
CFI-mode 1  
bit U/D  
bits MA6..MA3, MA0  
bits MA2..MA1  
Direction selection  
Time slot selection  
Logical CFI port number  
bit U/D  
Direction selection  
bits MA6..MA3, MA2, MA0 Time slot selection  
bit MA1  
Logical CFI port number  
CFI-mode 2  
CFI-mode 3  
bit U/D  
bits MA6..MA0  
Direction selection  
Time slot selection  
bit U/D  
Direction selection  
bits MA6..MA4, MA0  
bits MA3..MA1  
Time slot selection  
Logical CFI port number  
4.2.3.3 Memory Access Data Register (MADR)  
Access in demultiplexed µP-interface mode:  
read/write  
read/write  
address: 2H  
OMDR:RBS = 0  
address: 04H  
Access in multiplexed µP-interface mode:  
Reset value: xxH  
bit 7  
bit 0  
MD7  
MD6  
MD5  
MD4  
MD3  
MD2  
MD1  
MD0  
The Memory Access Data Register MADR contains the data to be transferred from or to  
a memory location. The meaning and the structure of this data depends on the kind of  
memory being accessed.  
Semiconductor Group  
66  
 
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.4  
Synchronous Transfer Registers  
4.2.4.1 Synchronous Transfer Data Register (STDA)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 3H  
OMDR:RBS = 0  
address: 06H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: xxH  
bit 7  
bit 0  
MTDA7  
MTDA6 MTDA5 MTDA4 MTDA3 MTDA2 MTDA1 MTDA0  
The STDA register buffers the data transferred over the synchronous transfer channel A.  
MTDA7 to MTDA0 hold the bits 7 to 0 of the respective time slot. MTDA7 (MSB) is the  
bit transmitted/received first, MTDA0 (LSB) the bit transmitted/received last over the  
serial interface.  
4.2.4.2 Synchronous Transfer Data Register B (STDB)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 4H  
OMDR:RBS = 0  
address: 08H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: xxH  
bit 7  
bit 0  
MTDB7  
MTDB6 MTDB5 MTDB4 MTDB3 MTDB2 MTDB1 MTDB0  
The STDB register buffers the data transferred over the synchronous transfer channel B.  
MTDB7 to MTDB0 hold the bits 7 to 0 of the respective time slot. MTDB7 (MSB) is the  
bit transmitted/received first, MTDB0 (LSB) the bit transmitted/received last over the  
serial interface.  
Semiconductor Group  
67  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.4.3 Synchronous Transfer Receive Address Register A (SARA)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 5H  
OMDR:RBS = 0  
address: 0AH  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: xxH  
bit 7  
bit 0  
ISRA  
MTRA6 MTRA5 MTRA4 MTRA3 MTRA2 MTRA1 MTRA0  
The SARA register specifies for synchronous transfer channel A from which input  
interface, port and time slot the serial data is extracted. This data can then be read from  
the STDA register.  
ISRA  
Interface Select Receive for channel A.  
0selects the PCM interface as the input interface for synchronous  
channel A.  
1selects the CFI interface as the input interface for synchronous  
channel A.  
MTRA6..0 µP Transfer Receive Address for channel A; selects the port and time slot  
number at the interface selected by ISRA according to tables 3 and 4:  
MTRA6..0 = MA6..0.  
Semiconductor Group  
68  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.4.4 Synchronous Transfer Receive Address Register B (SARB)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 6H  
OMDR:RBS = 0  
address: 0CH  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: xxH  
bit 7  
bit 0  
ISRB  
MTRB6 MTRB5 MTRB4 MTRB3 MTRB2 MTRB1 MTRB0  
The SARB register specifies for synchronous transfer channel B from which input  
interface, port and time slot the serial data is extracted. This data can then be read from  
the STDB register.  
ISRB  
Interface Select Receive for channel B.  
0selects the PCM interface as the input interface for synchronous  
channel B.  
1selects the CFI-interface as the input interface for synchronous  
channel B.  
MTRB6..0 µP-Transfer Receive Address for channel B; selects the port and time slot  
number at the interface selected by ISRB according to tables 3 and 4:  
MTRB6..0 = MA6..0.  
4.2.4.5 Synchronous Transfer Transmit Address Register A (SAXA)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 7H  
OMDR:RBS = 0  
address: 0EH  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: xxH  
bit 7  
bit 0  
ISXA  
MTXA6 MTXA5 MTXA4 MTXA3 MTXA2 MTXA1 MTXA0  
The SAXA register specifies for synchronous transfer channel A to which output  
interface, port and time slot the serial data contained in the STDA register is sent.  
ISXA  
Interface Select Transmit for channel A.  
0selects the PCM interface as the output interface for synchronous  
channel A.  
1selects the CFI interface as the output interface for synchronous  
channel A.  
MTXA6..0 µP-Transfer Transmit Address for channel A; selects the port and time slot  
number at the interface selected by ISXA according to tables 3 and 4:  
MTXA6..0 = MA6..0.  
Semiconductor Group  
69  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.4.6 Synchronous Transfer Transmit Address Register B (SAXB)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 8H  
OMDR:RBS = 0  
address: 10H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: xxH  
bit 7  
bit 0  
ISXB  
MTXB6 MTXB5 MTXB4 MTXB3 MTXB2 MTXB1 MTXB0  
The SAXB register specifies for synchronous transfer channel B to which output  
interface, port and time slot the serial data contained in the STDB register is sent.  
ISXB  
Interface Select Transmit for channel B.  
0selects the PCM interface as the output interface for synchronous  
channel B.  
1selects the CFI interface as the output interface for synchronous  
channel B.  
MTXB6..0 µP-Transfer Transmit Address for channel B; selects the port and time slot  
number at the interface selected by ISXB according to tables 3 and 4:  
MTXB6..0 = MA6..0.  
4.2.4.7 Synchronous Transfer Control Register (STCR)  
Access in demultiplexed µP-interface mode:  
read/write  
address: 09H  
OMDR:RBS = 0  
address: 12H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: 00xxxxxxB  
bit 7  
bit 0  
TBE  
TAE  
CTB2  
CTB1  
CTB0  
CTA2  
CTA1  
CTA0  
The STCR register bits are used to enable or disable the synchronous transfer utility and  
to determine the sub time slot bandwidth and position if a PCM interface time slot is  
involved.  
TAE, TBE Transfer Channel A (B) Enable.  
1… enables the µP transfer of the corresponding channel.  
0… disables the µP transfer of the corresponding channel.  
Semiconductor Group  
70  
PEB 2055  
PEF 2055  
Detailed Register Description  
CTA2..0 Channel Type A (B); these bits determine the bandwidth of the channel and  
CTB2..0 the position of the relevant bits in the time slot according to the table below.  
Note:Note that if a CFI time slot is selected as receive or transmit time slot of  
the synchronous transfer, the 64-kbit/s bandwidth must be selected  
(CT#2..CT#0 = 001).  
CT#2  
CT#1  
CT#0  
Bandwidth  
Transferred Bits  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
not allowed  
64 kbit/s  
32 kbit/s  
32 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
bits 7..0  
bits 3..0  
bits 7..4  
bits 1..0  
bits 3..2  
bits 5..4  
bits 7..6  
4.2.5  
Monitor/Feature Control Registers  
4.2.5.1 MF-Channel Active Indication Register (MFAIR)  
Access in demultiplexed µP-interface mode:  
read  
read  
address: AH  
OMDR:RBS = 0  
address: 14H  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
0
SO  
SAD5  
SAD4  
SAD3  
SAD2  
SAD1  
SAD0  
This register is only used in IOM-2 applications (active handshake protocol) in order to  
identify active monitor channels when the “Search for active monitor channels”  
command (CMDR:MFSO) has been executed.  
SO  
MF Channel Search On.  
0…the search is completed.  
1…the EPIC is still busy looking for an active channel.  
SAD5..0  
Subscriber Address 5..0; after an ISTA:MAC interrupt these bits point to the  
port and time slot where an active channel has been found. The coding is  
identical to MFSAR:SAD5..SAD0.  
Semiconductor Group  
71  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.5.2 MF-Channel Subscriber Address Register (MFSAR)  
Access in demultiplexed µP-interface mode:  
write  
address: AH  
OMDR:RBS = 0  
address: 14H  
Access in multiplexed µP-interface mode:  
write  
Reset value: xxH  
bit 7  
bit 0  
MFTC1  
MFTC0  
SAD5  
SAD4  
SAD3  
SAD2  
SAD1  
SAD0  
The exchange of monitor data normally takes place with only one subscriber circuit at a  
time. This register serves to point the MF handler to that particular CFI time slot.  
MFTC1..0 MF Channel Transfer Control 1..0; these bits, in addition to CMDR:MFT1,0  
and OMDR:MFPS control the MF channel transfer as indicated in table 5.  
SAD5..0  
Subscriber address 5..0; these bits define the addressed subscriber. The  
CFI time slot encoding is similar to the one used for Control Memory  
accesses using the MAAR register (tables 3 and 4):  
CFI time slot encoding of MFSAR derived from MAAR:  
MAAR: MA7  
MA6  
MA5  
MA4  
MA3  
MA2  
MA1  
MA0  
MFSAR: MFTC1 MFTC0 SAD5 SAD4 SAD3 SAD2 SAD1 SAD0  
MAAR:MA7 selects between upstream and downstream CM blocks. This information is  
not required since the transfer direction is defined by CMDR (transmit or receive).  
MAAR:MA0 selects between even and odd time slots. This information is also not  
required since MF channels are always located on even time slots.  
Semiconductor Group  
72  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.5.3 Monitor/Feature Control Channel FIFO (MFFIFO)  
Access in demultiplexed µP-interface mode:  
read/write  
address: BH  
OMDR:RBS = 0  
address: 16H  
Access in multiplexed µP-interface mode:  
read/write  
Reset value: empty  
bit 7  
bit 0  
MFD7  
MFD6  
MFD5  
MFD4  
MFD3  
MFD2  
MFD1  
MFD0  
The 16-byte bi-directional MFFIFO provides intermediate storage for data bytes to be  
transmitted or received over the monitor or feature control channel.  
MFD7..0 MF Data bits 7..0; MFD7 (MSB) is the first bit to be sent over the serial CFI,  
MFD0 (LSB) the last.  
Note: The byte n + 1 of an n-byte transmit message in monitor channel is not defined.  
4.2.6  
Status/Control Registers  
4.2.6.1 Signaling FIFO (CIFIFO)  
Access in demultiplexed µP-interface mode:  
read  
read  
address: CH  
OMDR:RBS = 0  
address: 18H  
Access in multiplexed µP-interface mode:  
Reset value: 0xxxxxxxB  
bit 7  
bit 0  
SBV  
SAD6  
SAD5  
SAD4  
SAD3  
SAD2  
SAD1  
SAD0  
The 9 byte deep CIFIFO stores the addresses of CFI time slots in which a C/I and/or a  
SIG value change has taken place. This address information can then be used to read  
the actual C/I or SIG value from the control memory.  
SBV  
Signaling Byte Valid.  
0the SAD6..0 bits are invalid.  
1the SAD6..0 bits indicate a valid subscriber address. The polarity of SBV  
is chosen such that the whole 8 bits of the CIFIFO can be copied to the  
MAAR register in order to read the upstream C/I or SIG value from the  
control memory.  
SAD6..0 Subscriber Address bits 6..0; The CM address which corresponds to the CFI  
time slot where a C/I or SIG value change has taken place is encoded in  
these bits. For C/I channels SAD6..0 point to an even CM-address (C/I  
value), for SIG channels SAD6..0 point to an odd CM-address (stable SIG  
value).  
Semiconductor Group  
73  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.6.2 Timer Register (TIMR)  
Access in demultiplexed µP-interface mode:  
write  
write  
address: CH  
OMDR:RBS = 0  
address: 18H  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
SSR  
TVAL6  
TVAL5  
TVAL4  
TVAL3  
TVAL2  
TVAL2  
TVAL0  
The EPIC timer can be used for 3 different purposes: timer interrupt generation  
(ISTA:TIG), FSC multiframe generation (CMD2:FC2..0 = 111) and last look period  
generation.  
SSR  
Signaling Sampling Rate.  
0… the last look period is defined by TVAL6..0.  
1… the last look period is fixed to 125 µs.  
TVAL6..0 Timer Value bits 6..0; the timer period, equal to (1+TVAL6..0) × 250 µs, is  
programmed here. It can thus be adjusted within the range of 250 µs up to  
32 ms.  
The timer is started as soon as CMDR:ST is set to 1 and stopped by writing the TIMR  
register or by selecting OMDR:OMS0 = 0.  
Semiconductor Group  
74  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.6.3 Status Register (STAR)  
Access in demultiplexed µP-interface mode:  
read  
read  
address: DH  
OMDR:RBS = 0  
address: 1AH  
Access in multiplexed µP-interface mode:  
Reset value: 05H  
bit 7  
bit 0  
MAC  
TAC  
PSS  
MFTO  
MFAB  
MFAE  
MFRW  
MFFE  
The status register STAR displays the current state of certain events within the EPIC.  
The STAR register bits do not generate interrupts and are not modified by reading  
STAR.  
MAC  
Memory Access  
0…no memory access is in operation.  
1a memory access is in operation. Hence, the memory access registers  
may not be used.  
Note:MAC is also set and reset during synchronous transfers.  
TAC  
PSS  
Timer Active  
0the timer is stopped.  
1the timer is running.  
PCM Synchronization Status.  
1the PCM interface is synchronized.  
0the PCM interface is not synchronized. There is a mismatch between the  
PBNR value and the applied clock and framing signals (PDC/PFS) or  
OMDR:OMS0 = 0.  
MFTO  
MFAB  
MFAE  
MFRW  
MFFE  
MF Channel Transfer in Operation.  
0no MF channel transfer is in operation.  
1an MF channel transfer is in operation.  
MF Channel Transfer Aborted.  
0the remote receiver did not abort a handshake message transfer.  
1the remote receiver aborted a handshake message transfer.  
MFFIFO Access Enable.  
0the MFFIFO may not be accessed.  
1the MFFIFO may be either read or written to.  
MFFIFO Read/Write.  
0the MFFIFO is ready to be written to.  
1the MFFIFO may be read.  
MFFIFO Empty  
0the MFFIFO is not empty.  
1the MFFIFO is empty.  
Semiconductor Group  
75  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.6.4 Command Register (CMDR)  
Access in demultiplexed µP-interface mode:  
write  
write  
address: DH  
OMDR:RBS = 0  
address: 1AH  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
0
ST  
TIG  
CFR  
MFT1  
MFT0  
MFSO  
MFFR  
Writing a logical 1 to a CMDR register bit starts the respective operation.  
ST  
Start Timer.  
0no action. If the timer shall be stopped, the TIMR register must simply be  
written with a random value.  
1starts the timer to run cyclically from 0 to the value programmed in  
TIMR:TVAL6..0.  
TIG  
Timer Interrupt Generation.  
0setting the TIG bit to logical 0 together with the CMDR:ST bit set to logical  
1 disables the interrupt generation.  
1setting the TIG bit to logical 1 together with CMDR:ST bit set to logical 1  
causes the EPIC to generate a periodic interrupt (ISTA:TIN) each time  
the timer expires.  
CFR  
CIFIFO Reset.  
0no action.  
1resets the signaling FIFO within 2 RCL periods, i.e. all entries and the  
ISTA:SFI bit are cleared.  
MFT1..0 MF channel Transfer Control Bits 1, 0; these bits start the monitor transfer  
enabling the contents of the MFFIFO to be exchanged with the subscriber  
circuits as specified in MFSAR. The function of some commands depends  
furthermore on the selected protocol (OMDR:MFPS). Table 5 summarizes all  
available MF commands.  
MFSO  
MF channel Search On.  
0no action.  
1the EPIC- starts to search for active MF channels. Active channels are  
characterized by an active MX bit (logical 0) sent by the remote  
transmitter. If such a channel is found, the corresponding address is  
stored in MFAIR and an ISTA:MAC-interrupt is generated. The search is  
stopped when an active MF channel has been found or when  
OMDR:OMS0 is set to 0.  
Semiconductor Group  
76  
PEB 2055  
PEF 2055  
Detailed Register Description  
MFFR  
MFFIFO Reset.  
0no action  
1resets the MFFIFO and all operations associated with the MF handler  
(except for the search function) within 2 RCL periods. The MFFIFO is set  
into the state “MFFIFO empty”, write access enabled and any monitor  
data transfer currently in process will be aborted.  
Table 5  
Summary of MF-Channel Commands  
Transfer Mode  
CMDR:  
MFT1,MFT0  
MFSAR  
Protocol  
Selection  
Application  
Inactive  
00  
01  
01  
01  
xxxxxxxx  
HS, no HS Idle state  
Transmit  
00 SAD5..0 HS, no HS IOM-2, IOM-1, SLD  
Transmit broadcast  
Test operation  
01xxxxxx  
10------  
HS, no HS IOM-2, IOM-1, SLD  
HS, no HS IOM-2, IOM-1, SLD  
Transmit continuous 11  
00 SAD5..0 HS  
IOM-2  
Transmit + receive  
same time slot  
Any # of bytes  
10  
10  
10  
10  
10  
00 SAD5..0 HS  
IOM-2  
IOM-1  
(IOM-1)  
(IOM-1)  
(IOM-1)  
1 byte expected  
2 bytes expected  
8 bytes expected  
16 bytes expected  
00 SAD5..0 no HS  
01 SAD5..0 no HS  
10 SAD5..0 no HS  
11 SAD5..0 no HS  
Transmit + receive  
same line  
1 byte expected  
2 bytes expected  
8 bytes expected  
16 bytes expected  
11  
11  
11  
11  
00 SAD5..0 no HS  
01 SAD5..0 no HS  
10 SAD5..0 no HS  
11 SAD5..0 no HS  
SLD  
SLD  
SLD  
SLD  
HS:  
handshake facility enabled (OMDR:MFPS = 1)  
no HS: handshake facility disable (OMDR:MFPS = 0)  
Semiconductor Group  
77  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.6.5 Interrupt Status Register (ISTA)  
Access in demultiplexed µP-interface mode:  
read  
read  
address: EH  
OMDR:RBS = 0  
address: 1CH  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
TIN  
SFI  
MFFI  
MAC  
PFI  
PIM  
SIN  
SOV  
The ISTA register should be read after an interrupt in order to determine the interrupt  
source.  
TIN  
Timer interrupt;  
a
timer interrupt previously requested with  
CMDR:ST,TIG = 1 has occurred. The TIN bit is reset by reading ISTA. It  
should be noted that the interrupt generation is periodic, i.e. unless stopped  
by writing to TIMR, the ISTA:TIN will be generated each time the timer  
expires.  
SFI  
Signaling FIFO Interrupt; this interrupt is generated if there is at least one  
valid entry in the CIFIFO indicating a change in a C/I or SIG channel.  
Reading ISTA does not clear the SFI bit. Instead SFI is cleared if the CIFIFO  
is empty which can be accomplished by reading all valid entries of the  
CIFIFO or by resetting the CIFIFO by setting CMDR:CFR to 1.  
MFFI  
MFFIFO Interrupt; the last MF-channel command (issued by CMDR:MFT1,  
MFT0) has been executed and the EPIC is ready to accept the next  
command. Additional information can be read from STAR:MFTO…MFFE.  
MFFI is reset by reading ISTA.  
MAC  
PFI  
Monitor channel Active interrupt; the EPIC has found an active monitor  
channel. A new search can be started by reissuing the CMDR:MFSO  
command. MAC is reset by reading ISTA.  
PCM Framing Interrupt; the STAR:PSS bit has changed its polarity. To  
determine whether the PCM-interface is synchronized or not, STAR must be  
read. The PFI bit is reset by reading ISTA.  
PIM  
PCM Input Mismatch; this interrupt is generated immediately after the  
comparison logic has detected a mismatch between a pair of PCM input  
lines. The exact reason for the interrupt can be determined by reading the  
PICM register. Reading ISTA clears the PIM-bit. A new PIM interrupt can  
only be generated after the PICM register has been read.  
Semiconductor Group  
78  
PEB 2055  
PEF 2055  
Detailed Register Description  
SIN  
Synchronous transfer Interrupt; The SIN interrupt is enabled if at least one  
synchronous transfer channel (A and/or B) is enabled via the STCR:TAE,  
TBE bits. The SIN interrupt is generated when the access window for the µP  
opens. After the occurrence of the SIN interrupt the µP can read and/or write  
the synchronous transfer data registers (STDA, STDB). The SIN bit is reset  
by reading ISTA.  
SOV  
Synchronous transfer Overflow; The SOV interrupt is generated if the µP fails  
to access the data registers (STDA, STDB) within the access window. The  
SOV bit is reset by reading ISTA.  
4.2.6.6 Mask Register (MASK)  
Access in demultiplexed µP-interface mode:  
write  
write  
address: EH  
OMDR:RBS = 0  
address: 1CH  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
TIN  
SFI  
MFFI  
MAC  
PFI  
PIM  
SIN  
SOV  
A logical 1 disables the corresponding interrupt as described in the ISTA-register.  
A masked interrupt is stored internally and reported in ISTA immediately if the mask is  
released. However, an SFI interrupt is also reported in ISTA if masked. In this case no  
interrupt is generated. When writing register MASK while ISTA indicates a non masked  
interrupt INT is temporarily set into the inactive state.  
Semiconductor Group  
79  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.6.7 Operation Mode Register (OMDR)  
Access in demultiplexed µP-interface mode:  
read/write  
read/write  
address: FH  
OMDR:RBS = X  
address: 1EH/3EH  
Access in multiplexed µP-interface mode:  
Reset value: 00H  
bit 7  
bit 0  
OMS1  
OMS0  
PSB  
PTL  
COS  
MFPS  
CSB  
RBS  
OMS1..01 Operational Mode Selection; these bits determine the operation mode of the  
EPIC according to the following table:  
OMS1..0 Function  
00  
The CM reset mode is used to reset all locations of the control  
memory code and data fields with a single command within only  
256 RCL cycles. A typical application is resetting the CM with the  
command MACR = 70H which writes the contents of MADR (xxH)  
to all data field locations and the code ’0000’ (unassigned  
channel) to all code field locations. A CM reset should be made  
after each hardware reset. In the CM-reset mode the EPIC does  
not operate normally i.e. the CFI- and PCM-interfaces are not  
operational.  
10  
The CM initialization mode allows fast programming of the  
control memory since each memory access takes a maximum of  
only 2.5 RCL cycles compared to the 9.5 RCL cycles in the  
normal mode. Accesses are performed on individual addresses  
specified by MAAR. The initialization of control/signaling  
channels in IOM or SLD applications can for example be carried  
out in this mode. In the CM initialization mode the EPIC does also  
not work normally.  
11  
01  
In the normal operation mode the CFI and PCM interfaces are  
operational. Memory accesses performed on single addresses  
(specified by MAAR) take 9.5 RCL cycles. An initialization of the  
complete data memory tristate field takes 1035 RCL cycles.  
In test mode the EPIC sustains normal operation. However  
memory accesses are no longer performed on a specific address  
defined by MAAR, but on all locations of the selected memory,  
the contents of MAAR (including the U/D bit!) being ignored. A  
test mode access takes 2057 RCL cycles.  
Semiconductor Group  
80  
PEB 2055  
PEF 2055  
Detailed Register Description  
PSB  
PTL  
PCM Standby.  
0…the PCM interface output pins TxD0..3 are set to high impedance and  
those TSC pins that are actually used as tristate control signals are set  
to logical 1 (inactive).  
1…the PCM output pins transmit the contents of the upstream data memory  
or may be set to high impedance via the data memory tristate field.  
PCM Test Loop.  
0…the PCM test loop is disabled.  
1…the PCM test loop is enabled, i.e. the physical transmit pins TxD# are  
internally connected to the corresponding physical receive pins RxD#,  
such that data transmitted over TxD# are internally looped back to RxD#  
and data externally received over RxD# are ignored. The TxD# pins still  
output the contents of the upstream data memory according to the setting  
of the tristate field (only modes 0 and 1; mode 1 with AIS bit set).  
COS  
MFPS  
CSB  
CFI Output driver Selection.  
0…the CFI output drivers are tristate drivers.  
1…the CFI output drivers are open drain drivers.  
Monitor/Feature control channel Protocol Selection.  
0…handshake facility disabled (SLD and IOM-1 applications)  
1…handshake facility enabled (IOM-2 applications)  
CFI Standby.  
0…the CFI interface output pins DD0..3, DU0..3, DCL and FSC are set to  
high impedance.  
1…the CFI output pins are active.  
RBS  
Register Bank Selection. Used in demultiplexed data/address modes only.  
0…to access the registers used during device operation  
1…to access the registers used during device initialization.  
Semiconductor Group  
81  
PEB 2055  
PEF 2055  
Detailed Register Description  
4.2.6.8 Version Number Status Register (VNSR)  
Access in demultiplexed µP-interface mode:  
read  
address: DH  
OMDR:RBS = 1  
address: 3AH  
Access in multiplexed µP-interface mode:  
read  
Reset value: 0xH  
bit 7  
bit 0  
IR  
0
0
0
VN3  
VN2  
VN1  
VN0  
The VNSR register bits do not generate interrupts and are not modified by reading  
VNSR. The IR and VN3..0 bits are read only bits, the SWRX bit is a write only bit.  
IR  
Initialization Request; this bit is set to logical 1 after an inappropriate clocking  
or after a power failure. It is reset to logical 0 after a control memory reset  
command: OMDR:OMS1..0 = 00, MACR = 7X.  
VN3..0  
Version status Number; these bits display the EPIC-1 chip version as follows  
VN3..0  
0000  
Chip Versions  
A1, A2, A3 (EPIC-1)  
1.0 (EPIC-S)  
0000  
Semiconductor Group  
82  
PEB 2055  
PEF 2055  
Application Hints  
5
Application Hints  
Introduction  
5.1  
5.1.1  
IOM® and SLD Functions  
IOM® (ISDN Oriented Modular) Interface  
The IOM-2 standard defines an industry standard serial bus for interconnecting  
telecommunications ICs. The standard covers line card, NT1, and terminal architectures  
for ISDN, DECT and analog loop applications. The IOM-2 standard is a derivative of the  
IOM-1 interface formerly designed by Siemens to interconnect layer-1 and layer-2  
devices within ISDN terminals and on digital line cards.  
The IOM®-1 interface provides a symmetrical full-duplex communication link, containing  
user data, control/programming, and status channels for 1 ISDN subscriber, i.e. it  
provides capacity for 2 B channels at 64 kbit/s and 1 D channel at 16 kbit/s. The IOM-1  
channel consists of four 8 bit time slots which are serially transferred within an 8 kHz  
frame. The first 2 time slots carry the B1 and B2 channels, the third time slot carries an  
8 bit monitor channel and the fourth time slot carries the 2 bit D channel, a 4 bit  
Command/Indication (C/I) channel plus 2 additional control bits (T and E bits). The  
monitor channel serves to exchange control and status information in a message  
oriented fashion of one byte per message. The C/I channel carries real-time status  
information between the line transceiver and the layer-2 device or the line card  
controller. Status information transmitted over the C/I channel is “static” in the sense that  
the 4 bit word is repeatedly transmitted, every frame, as long as the status condition that  
it indicates is valid. The T bit is used by some U layer-1 devices as a transparent  
channel. The E bit is used in conjunction with the monitor channel to indicate the transfer  
of a monitor byte to the slave device. The various channels are time-multiplexed over a  
four wire serial interface. The data transfer rate at the IOM-1 interface is 256 kbit/s, the  
data is clocked with a double rate clock of 512 kHz (DCL) and the frame is synchronized  
by an 8 kHz framing signal (FSC).  
Because the IOM-1 interface structure can handle only 1 ISDN channel, which is too little  
for line card applications, the multiplexed IOM®-1 bus was developed. It multiplexes 8  
individual IOM-1 channels into the 8 kHz frame. The data transfer rate is now increased  
to 2.048 Mbit/s, the data is clocked with a double rate clock of 4.096 MHz (DCL) and the  
frame is synchronized with an 8 kHz framing signal (FSC). The bit timing and FSC  
position differs slightly from the 256 kbit/s IOM-1 interface. The IOM channel structure  
however is identical to the non-multiplexed IOM-1 case.  
The IOM®-2 bus standard is an enhancement of both the IOM-1 and multiplexed IOM-1  
standards. Both the line card and terminal portions of the IOM-2 standard utilize the  
same basic frame and clocking structure, but differ in the number and usage of the  
individual channels. Data is clocked by a data clock (DCL) that operates at twice the data  
Semiconductor Group  
83  
 
PEB 2055  
PEF 2055  
Application Hints  
rate. Frames are delimited by an 8 kHz frame synchronization signal (FSC). The bit  
timing and FSC position is identical to the non-multiplexed IOM-1 case.  
The line card version of the IOM®-2 provides a connection path between line  
transceivers (ISDN) or codecs (analog), and the line card controller, the EPIC. The line  
card controller provides the connection to the switch backbone. The IOM-2 bus  
time-multiplexes data, control, and status information for up to 8 ISDN transceivers or up  
to 16 codec/filters over a single full-duplex interface.  
Figure 22 shows the IOM-2 frame structure for the line card. It consists of 8 individual  
and independent IOM channels, each having a structure similar to the IOM-1 channel  
structure. The main difference compared to IOM-1 is the more powerful monitor channel  
performance. Monitor messages of unlimited length can now be transferred at a variable  
speed, controlled by a handshake procedure using the MR and MX bits. The C/I channel  
can have a width of 4 bits for ISDN applications or of 6 bits for analog signaling  
applications.  
FSC  
(8 kHz)  
DCL  
(4096 kHz)  
DD#  
(2048 kbit/s)  
R
R
R
R
R
R
R
R
IOM Ch. 0 IOM Ch. 1 IOM Ch. 2 IOM Ch. 3 IOM Ch. 4 IOM Ch. 5 IOM Ch. 6 IOM Ch. 7  
DU#  
(2048 kbit/s)  
R
R
R
R
R
R
R
R
IOM Ch. 0 IOM Ch. 1 IOM Ch. 2 IOM Ch. 3 IOM Ch. 4 IOM Ch. 5 IOM Ch. 6 IOM Ch. 7  
0
1
2
3
4
5
6
7
8
31  
Time-Slot  
Number  
B1 Channel  
8 Bits  
B2 Channel  
8 Bits  
Monitor Channel  
8 Bits  
Control Channel  
8 Bits  
M M  
R X  
B1 : 64 kbit/s Channel  
B2 : 64 kbit/s Channel  
ISDN:  
D
C/I  
D
: 16 kbit/s Channel  
M M  
R X  
C/I : Command/Indication Channel  
SIG : Signaling Channel  
Analog:  
SIG  
MR : Monitor Handshake Bit "Receive"  
MX : Monitor Handshake Bit "Transmit"  
ITD08037  
Figure 22  
IOM®-2 Frame Structure for Line Card Applications  
Semiconductor Group  
84  
 
PEB 2055  
PEF 2055  
Application Hints  
The terminal version of the IOM®-2 is a variation of the line card bus, designed for  
ISDN terminal and NT1 applications. It consists of three IOM channels, each containing  
four 8 bit time slots. The resultant data transfer rate is therefore 768 kbit/s and the data  
is clocked with a 1536 kHz double rate clock (DCL). The IOM channel structure is similar  
to the line card case. The first channel is dedicated for controlling the layer-1 transceiver  
(monitor and C/I channels) and passing the user data (B and D channels) to the layer-1  
transceiver. The second and third channels are used for communication between a  
controlling device and devices other than the layer-1 transceiver, or for transferring user  
data between data processing devices (IC channels). The C/I channel of the third IOM  
channel is used for TIC bus applications (D and C/I channel arbitration). The TIC bus  
allows multiple layer-2 devices to individually gain access to the D and C/I channels  
located in the first IOM channel.  
Finally, for NT1 applications, it is also possible to operate the IOM-2 interface at a data  
rate of 256 kbit/s (1 IOM channel). This is sufficient for the simple back to back  
connection of layer-1 transceivers in Network Terminator (NT) and Repeater (RP)  
applications.  
The following table summarizes the different operation modes and applications of the  
IOM-1 and IOM-2 standards (TE = Terminal Equipment, NT = Network Terminator,  
LT = Line Terminator):  
Table 6  
Mode  
Applications  
Data Rate / Clock Rate  
256 kbit/s / 512 kHz  
IOM-1  
TE, NT, LT  
LT  
Multiplexed IOM-1  
IOM-2  
2.048 Mbit/s / 4.096 MHz  
2.048 Mbit/s / 4.096 MHz  
768 kbit/s / 1.536 MHz  
256 kbit/s / 512 kHz  
LT  
IOM-2  
TE, NT  
NT  
IOM-2  
The main application of the EPIC is on digital and analog line cards. The EPIC is  
therefore primarily designed to support the line card modes (2.048 Mbit/s) of the IOM-2  
standard. It can however be programmed to support all the above mentioned IOM data  
rates and C/I and monitor processing schemes. However, it must be assured that the  
desired PCM to IOM data rate ratio is feasible (refer to chapter 5.2.2.3).  
Semiconductor Group  
85  
PEB 2055  
PEF 2055  
Application Hints  
SLD (Subscriber Line Data) Interface  
The SLD bus is used by the EPIC to interface with the subscriber line devices. A Serial  
Interface Port (SIP) is used for the transfer of all digital voice and data, feature control  
and signaling information between the individual subscriber line devices, the PCM  
highways and the control backplane. The SLD approach provides a common interface  
for one analog or digital component per line. The EPIC switches the PCM data  
transparently switched onto the PCM highways.  
There are three wires connecting each subscriber line device and the EPIC: two  
common clock signals shared among all devices, and a unique bidirectional data wire for  
each of the eight SIP ports. The direction signal (FSC) is an 8 kHz clock output from the  
EPIC (master) that serves as a frame synch to the subscriber line devices (slave) as well  
as a transfer indicator. The data is transferred at a 512 kHz data rate, clocked by the  
subscriber clock (DCL). When FSC is high (first half of the 125 µs SLD frame), four bytes  
of digital data are transmitted on the SLD bus from the EPIC to the slave (downstream  
direction). During the second half of the frame when FSC is low, four bytes of data are  
transferred from the slave back to the EPIC (upstream direction).  
Channel B1 and B2 are 64 kbit/s channels reserved for voice and data to be routed to  
and from the PCM highways. The third and seventh byte are used to transmit and  
receive control information for programming the slave devices (feature control channel).  
The last byte in each direction is reserved for signaling data.  
FSC  
(8 kHz)  
DCL  
(512 kHz)  
B1  
B2  
FC  
SIG  
B1  
B2  
FC  
SIG  
SIP  
(512 kbit/s)  
TS 0  
TS 1  
TS 2  
TS 3  
TS 4  
TS 5  
TS 6  
TS 7  
Downstream  
SIP Output  
Upstream  
SIP Input  
B1 : 64 kbit/s Channel  
B2 : 64 kbit/s Channel  
FC : Feature Control Channel (8 Bit)  
SIG : Signaling Channel (8 Bit)  
ITD08038  
Figure 23  
SLD Frame Structure  
In contrast to other Siemens telecom devices, the EPIC does not provide an “IOM mode”  
or an “SLD mode” that can be selected by programming a single “mode bit”. Instead, the  
EPIC provides a configurable interface (CFI) that can be configured for a great variety of  
interfaces, including IOM-1, multiplexed IOM-1, IOM-2 and SLD interfaces.  
Semiconductor Group  
86  
PEB 2055  
PEF 2055  
Application Hints  
The Characteristics of the Different IOM® and SLD Interfaces can be Divided into  
Two Groups  
• Timing characteristics and  
• Handling of special channels (C/I or signaling channel, monitor or feature control  
channel)  
The timing characteristics (data rate, clock rate, bit timing, etc. … ) are programmed in  
the CFI registers (see chapter 5.2.2.2). The CFI data rate, for example, can be selected  
between 128 kbit/s and 8.192 Mbit/s. This covers the standard IOM and SLD data rates  
of 256, 512, 768 kbit/s and 2.048 Mbit/s.  
The special channels are initialized on a per time slot basis in the control memory (CM).  
This programming on a per time slot basis allows a dedicated usage of each CFI port  
and time slot: an application that requires only two IOM-2 compatible layer-1  
transceivers will also only occupy 8 CFI time slots (2 IOM channels) for that purpose.  
The remaining 24 time slots can then be used for general switching applications or for  
the connection of non IOM-2 compatible devices that require a special µP handling.  
The Special Channels can be Divided into Two Groups  
• Monitor/Feature Control channels and  
• Control/Signaling channels  
The Monitor/Feature Control handler can be adjusted to operate according to the  
– IOM-1 protocol (up to 1 byte, no handshake), the  
– IOM-2 protocol (any number of bytes, handshake using the MR and MX bits) and to  
the  
– SLD protocol (up to 16 bytes in subsequent frames without handshake)  
The Monitor/Feature Control handler is a dedicated unit that communicates only with  
one IOM or SLD channel at a time. An address register selects one out of 64 possible  
MF channels. A 16 byte bidirectional FIFO (MFFIFO) provides intermediate storage for  
the data to be sent or received. The message transfer over the MF channel is always  
half-duplex, i.e. data can either be sent at a time or received at a time.  
Note: If the IOM-2 protocol is selected, the actual message length i.e. the number of  
bytes to be sent or received is unlimited and is not restricted by the MFFIFO size!  
If non handshake protocols (IOM-1 and SLD) are used, the EPIC must always be the  
master of the MF communication. Example: the EPIC programs and reads back the  
coefficients of a SICOFI (PEB 2060) device.  
If the handshake protocol is used (IOM-2), a balanced MF communication is also  
possible: since the MF handler cannot be pointed to all IOM-2 channels at the same time,  
the EPIC has implemented a search function that looks for active monitor transmit  
handshake (MX) bits on all upstream IOM-2 channels. If an active channel is found, the  
address is stored and an interrupt is generated. The MF handler can then be pointed to  
Semiconductor Group  
87  
PEB 2055  
PEF 2055  
Application Hints  
that particular channel and the message transfer can take place.  
Example: the EPIC reads an EOC message out of an IEC-Q (PEB 2091) device.  
The Control/Signaling handler can be adjusted to handle the following types of  
channels:  
• 4 bit C/I channel (IOM-1 and digital IOM-2)  
• 6 bit C/I or Signaling channel (analog IOM-2)  
• 8 bit Signaling channel (SLD)  
In downstream direction, the µP can write the 4, 6 or 8 bit C/I or Signaling value to be  
transmitted directly to the CFI time slot i.e. to the control memory. This value will then be  
transmitted repeatedly in each frame until a new value is loaded.  
If the 4 bit C/I channel option is selected, the two D channel bits can either be tristated  
by the EPIC (decentral D channel handling scheme) or they can be switched  
transparently from any 2 bit subtime slot position at the PCM interface (central D channel  
handling scheme).  
In upstream direction, the µP can read the received 4, 6, or 8 bit C/I or Signaling value  
directly from the CFI time slot i.e. from the control memory. In addition the  
Control/Signaling handler checks all received C/I and Signaling channels for changes.  
Upon a change:  
– an interrupt is generated,  
– the address of the involved CFI time slot is stored in a 9 byte FIFO (CIFIFO) and  
– the new value is stored in the control memory.  
The CIFIFO serves to buffer the address information in order to increase the µP latency  
time.  
The change detection mechanism is based on a single last look procedure for 4 bit C/I  
channels and on a double last look procedure for 6 and 8 bit C/I or Signaling channels.  
The single last look period is fixed to 125 µs, whereas the double last look period is  
programmable from 125 µs to 32 ms. The last look period is programmed using the EPIC  
timer.  
With the single last look procedure, each C/I value change immediately leads to a valid  
change and thus to an interrupt.  
With the double last look procedure, a C/I or Signaling value change must be detected  
two times at the sampling points of the last look interval before a valid change is  
recognized and an interrupt is generated.  
If the 4 bit C/I channel option is selected, the two D channel bits can either be ignored  
by the EPIC (decentral D channel handling scheme) or they can be switched  
transparently to any 2 bit subtime slot position at the PCM interface (central D channel  
handling scheme).  
Semiconductor Group  
88  
PEB 2055  
PEF 2055  
Application Hints  
5.2  
Configuration of Interfaces  
PCM Interface Configuration  
5.2.1  
5.2.1.1 PCM Interface Signals  
The PCM interface signals are summarized in table 7.  
Table 7  
Pin No.  
Symbol  
I: Input  
Function  
O: Output  
9
TxD0  
TxD1  
TxD2  
TxD3  
O
O
O
O
Transmit PCM interface data: serial data is sent at  
standard TTL or CMOS levels (tristate drivers).  
These pins can be set to high impedance with a  
2 bit resolution.  
11  
13  
15  
8
TSC0  
TSC1  
TSC2  
TSC3  
O
O
O
O
Tristate control signals for the PCM transmit lines.  
These signals are low when the corresponding  
TxD# outputs are valid.  
10  
12  
14  
6
5
4
3
RxD0  
RxD1  
RxD2  
RxD3  
I
I
I
I
Receive PCM interface data: serial data is  
received at standard TTL or CMOS levels.  
16  
17  
PFS  
PDC  
I
I
PCM interface frame synchronization signal.  
PCM interface data clock, single or double data  
rate.  
5.2.1.2 PCM Interface Registers  
The characteristics at the PCM interface (timing, modes of operation, etc. … ) are  
programmed in the 4 PCM interface registers and in the Operation Mode Register  
OMDR. The function of each bit is described in chapter 5.2.1.3. For addresses, refer to  
chapter 4.1.  
PCM Mode Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
PMOD  
PMD1  
PMD0  
PCR  
PSM  
AIS1  
AIS0  
AIC1  
AIC0  
Semiconductor Group  
89  
 
PEB 2055  
PEF 2055  
Application Hints  
PCM Bit Number Register  
read/write  
reset value:  
FFH  
bit 0  
bit 7  
PBNR  
BNF7  
BNF6  
BNF5  
BNF4  
BNF3  
BNF2  
BNF1  
BNF0  
PCM Offset Downstream Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
POFD  
OFD9  
OFD8  
OFD7  
OFD6  
OFD5  
OFD4  
OFD3  
OFD2  
PCM Offset Upstream Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
POFU  
OFU9  
OFU8  
OFU7  
OFD0  
OFU6  
OFU5  
OFU4  
OFU3  
OFU2  
PCM Clock Shift Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
PCSR  
0
OFD1  
DRE  
0
OFU1  
OFU0  
URE  
Operation Mode Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
OMDR  
OMS1 OMS0  
PSB  
PTL  
COS  
MFPS  
CSB  
RBS  
Semiconductor Group  
90  
PEB 2055  
PEF 2055  
Application Hints  
5.2.1.3 PCM Interface Characteristics  
In the following the PCM interface characteristics that can be programmed in the PCM  
interface registers are explained in more detail.  
PCM Mode PMOD: PMD1, PMD0  
The PCM mode primarily defines the actual number of PCM highways that can be used  
for switching purposes (logical ports). 1, 2, or 4 logical PCM ports can be selected. Since  
the channel capacity of the EPIC is constant (128 channels per direction), the PCM  
mode also influences the maximum possible data rate. In each PCM mode a minimum  
data rate as well as a minimum data rate stepping are specified.  
It should also be noticed that there are some restrictions concerning the PCM to CFI data  
rate ratio which may affect some applications. These restrictions are described in  
chapter 5.2.2.3.  
The table below summarizes the specific characteristics of each PCM mode (DR = PCM  
data rate):  
Table 8  
PMD1 PMD0 PCM  
Number (Label)  
Data Rate Data Rate PDC  
Mode of Logical Ports  
[kbit/s]  
Stepping  
[kbit/s]  
Frequency  
(Clock Rate)  
min. max.  
0
0
1
0
1
0
0
1
2
4 (0 … 3)  
2 (0 … 1)  
1
256 2048 256  
512 4096 512  
1024 8192 1024  
DR, 2 × DR  
DR, 2 × DR  
DR  
Note: The label is used to specify a PCM port (logical port) when programming a  
switching function. It should not be confused with the physical port number which  
refers to actual hardware pins. The relationship between logical and physical port  
numbers is given in table 13 and is illustrated in figure 28.  
PCM Clock Rate PMOD:PCR  
The PCM interface is clocked via the PDC pin. If PCR is set to logical 0, the PDC  
frequency must be identical to the selected data rate (single clock operation). If PCR is  
set to logical 1, the PDC frequency must be twice the selected data rate (double clock  
operation).  
Note: In PCM mode 2, only single clock rate operation is allowed.  
In PCM mode 0 for example, PCR can be set to 1 to operate at up to four 2.048 MHz  
PCM highways with a PCM clock of 4.096 MHz.  
Semiconductor Group  
91  
PEB 2055  
PEF 2055  
Application Hints  
PCM Bit Number PBNR:BNF7 … BNF0  
The PCM data rate is determined by the clock frequency applied to the PDC pin and the  
clock rate selected by PMOD:PCR. The number of bits which constitute a PCM frame  
can be derived from this data rate by dividing by 8000 (8 kHz frame structure).  
If the PCM interface is for example operated at 2.048 Mbit/s, the frame would consist of  
256 bits or 32 time slots.  
Note: There is a mode dependent restriction on the possible number of bits per frame  
BPF:  
Table 9  
PCM Mode  
Possible Values for BNF  
0
1
2
BPF must be modulo 32  
BPF must be modulo 64  
BPF must be modulo 128  
This number of bits must be programmed to PBNR:BNF7 … 0 as indicated in table 10.  
Table 10  
PCM Mode  
PBNR:BNF7 … 0(Hex)  
0
1
2
BPF7 … 0 = BPF – 1  
BPF7 … 0 = (BPF – 2)/2  
BPF7 … 0 = (BPF – 4)/4  
The externally applied frame synchronization pulse PFS resets the internal PCM time  
slot and bit counters. The value programmed to PBNR is internally used to reset the  
PCM time slot and bit counters so that these counters always count modulo the actual  
number of bits per frame even in the absence of the external PFS pulse. Additionally, the  
PFS period is internally checked against the PBNR value. The result of this comparison  
is displayed in the PCM Synchronization Status bit (STAR:PSS). Also, refer to  
chapter 5.8.3.  
Examples  
In PCM mode 0 a PCM frame consisting of 32 time slots would require a setting of  
PBNR = 32 × 8 – 1 = 255D = FFH.  
In PCM mode 1 a PCM frame consisting of 24 time slots would require a setting of  
PBNR = (24 × 8 – 2)/2 = 95D = 5FH.  
In PCM mode 2 a PCM frame consisting of 64 time slots would require a setting of  
PBNR = (64 × 8 – 4)/4 = 127D = 7FH.  
Semiconductor Group  
92  
 
PEB 2055  
PEF 2055  
Application Hints  
PCM Synchronization Mode PMOD:PSM  
The PCM interface is synchronized via the PFS signal. A transition from low to high of  
PFS synchronizes the PCM frame. It should be noted that the rising PFS edge does not  
directly synchronize the frame, it is instead first internally sampled with the PDC clock:  
If PSM is set to logical 0, the PFS signal is sampled with the falling clock edge of PDC,  
if it is set to logical 1, the PFS signal is sampled with the rising clock edge of PDC.  
PSM should be selected such that the PDC signal detects stable low and high levels of  
the PFS signal, meeting the set-up (TFS) and hold (TFH) times with respect to the  
programmed PDC clock edge.  
In other words, if for example the rising PFS edge has some jitter with respect to the  
rising PDC edge, the falling PDC edge should be taken for the evaluation.  
The high phase of the PFS pulse may be of arbitrary length, however it must be assured  
that it is sampled low at least once before the next framing pulse.  
The relationship between the PFS signal and the beginning of the PCM frame is given  
in figure 24 and figure 25.  
PCM Bit Timing and Bit Shift POFD, POFU, PCSR  
The position of the PCM frame can be shifted relative to the framing source PFS in  
increments of bits by programming the PCM offset bits OFD9 … 0, OFU9 … 0 in the  
POFD, POFU and PCSR. This shifting can be performed separately for up- and  
downstream directions and by up to a whole frame. Additionally, the polarity of the PDC  
clock edge used for transmitting and sampling the data can be selected with the URE  
and DRE bits in the PCSR register.  
The time slot structure on the PCM interface is synchronized with the externally applied  
PFS pulse. The rising edge of PFS, after it has been sampled by the PDC signal, marks  
the first bit of the PCM frame. This first bit is referenced to as the BND (Bit Number  
Downstream) of the downstream and the BNU (Bit Number Upstream) of the upstream  
frame.  
If PCSR:URE is set to 1, data is transmitted with the rising edge of PDC, if URE is set to  
0, data is transmitted with the next following falling edge of PDC.  
If PCSR:DRE is set to 0, data is sampled with the falling edge of PDC, if DRE is set to  
1, data is sampled with the next following rising edge of PDC.  
The relationship between the PFS, PDC signals and the PCM bit stream on RxD# and  
TxD# is illustrated in figure 24 and figure 25.  
Semiconductor Group  
93  
PEB 2055  
PEF 2055  
Application Hints  
Conditions:  
PFS  
PDC  
PMOD : PSM = 0  
TxD#  
TxD#  
RxD#  
1st Bit  
2nd Bit 3rd Bit  
...  
...  
...  
...  
PMOD : PCR = 0, PCSR : URE = 1  
PMOD : PCR = 0, PCSR : URE = 0  
PMOD : PCR = 0, PCSR : DRE = 0  
1st Bit  
2nd Bit 3rd Bit  
...  
...  
...  
1st Bit  
2nd Bit 3rd Bit  
RxD#  
PMOD : PCR = 0, PCSR : DRE = 1  
1st Bit  
2nd Bit 3rd Bit  
2nd Bit  
...  
TxD#  
TxD#  
RxD#  
1st Bit  
3rd Bit  
PMOD : PCR = 1, PCSR : URE = 1  
PMOD : PCR = 1, PCSR : URE = 0  
PMOD : PCR = 1, PCSR : DRE = 0  
1st Bit  
2nd Bit  
2nd Bit  
3rd Bit  
1st Bit  
3rd Bit  
...  
RxD#  
PMOD : PCR = 1, PCSR : DRE = 1  
ITT08039  
1st Bit  
2nd Bit  
3rd Bit  
...  
Figure 24  
PCM Interface Framing Offset for PMOD:PSM = 0  
Semiconductor Group  
94  
 
PEB 2055  
PEF 2055  
Application Hints  
Conditions:  
PFS  
PDC  
PMOD: PSM = 1  
TxD#  
TxD#  
RxD#  
1st Bit 2nd Bit 3rd Bit  
1st Bit 2nd Bit 3rd Bit  
...  
...  
...  
...  
PMOD : PCR = 0, PCSR : URE = 1  
PMOD : PCR = 0, PCSR : URE = 0  
PMOD : PCR = 0, PCSR : DRE = 0  
...  
...  
...  
1st Bit 2nd Bit 3rd Bit  
1st Bit 2nd Bit 3rd Bit  
RxD#  
PMOD : PCR = 0, PCSR : DRE = 1  
...  
TxD#  
TxD#  
RxD#  
1st Bit  
2nd Bit  
3rd Bit  
PMOD : PCR = 1, PCSR : URE = 1  
PMOD : PCR = 1, PCSR : URE = 0  
PMOD : PCR = 1, PCSR : DRE = 0  
1st Bit  
2nd Bit  
2nd Bit  
3rd Bit  
1st Bit  
3rd Bit  
...  
...  
RxD#  
PMOD : PCR = 1, PCSR : DRE = 1  
ITT08040  
1st Bit  
2nd Bit  
3rd Bit  
...  
Figure 25  
PCM Interface Framing for PMOD:PSM = 1  
The formulas given in table 11 and table 12 apply for calculating the values to be  
programmed to the offset registers (OFD, OFU) given the desired bit number (BND,  
BNU) to be marked. BPF denotes the actual number of bits constituting a frame.  
Table 11  
PCM Mode Offset Downstream, POFD, PCSR  
Remarks  
0
1
2
OFD9 … 2 = (BND – 17 + BPF)mod BPF  
OFD9 … 1 = (BND – 33 + BPF)mod BPF  
OFD9 … 0 = (BND – 65 + BPF)mod BPF  
PCSR:OFD1 … 0 = 0  
PCSR:OFD0 = 0  
Semiconductor Group  
95  
 
 
PEB 2055  
PEF 2055  
Application Hints  
Table 12  
PCM Mode  
Offset Upstream, POFU, PCSR  
Remarks  
0
1
2
OFU9 … 2 = (BNU + 23)mod BPF  
OFU9 … 1 = (BNU + 47)mod BPF  
OFU9 … 0 = (BNU + 95)mod BPF  
PCSR:OFU1 … 0 = 0  
PCSR:OFU0 = 0  
Examples  
1) In PCM mode 0, with a frame consisting of 32 time slots, the following timing  
relationship between the framing signal and the data signals is required:  
1
PFS  
PDC  
PMOD : PSM = 0  
0
Start of Internal Frame  
TxD#  
RxD#  
BNU  
BND  
PCSR : URE = 1  
PCSR : DRE = 0  
256  
1
2
3
4
5
6
7
8
9
10  
Required  
Time-Slot  
and Bit  
Bit 7  
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0  
Offset  
Time-Slot 0  
ITT08041  
Figure 26  
Timing PCM Frame Offset for Example 1  
Semiconductor Group  
96  
 
PEB 2055  
PEF 2055  
Application Hints  
The PCM interface shall be clocked with a PDC having the same frequency as the data  
rate i.e. 2.048 MHz. Since the rising edge of PFS occurs at the same time as the rising  
edge of PDC, it is recommended to select the falling PDC edge for sampling the PFS  
signal (PMOD:PSM0 = 0). In this case the 1st bit of internal framing structure (according  
to figure 26) will represent time slot 0, bit 6 (2nd bit) of the external frame (according to  
figure 24). The values to be programmed to the POFD, POFD and PCSR can now be  
determined as follows:  
With BND = BNU = 2 and BPF = 256:  
POFD = OFD9 … 2 = (BND – 17 + BPF)mod BPF = (2 – 17 + 256)mod 256 = 241D = F1H  
POFU = OFU9 … 2 = (BNU + 23)mod BPF = (2 + 23)mod 256 = 25D = 19H  
With URE = 1 and DRE = 0:  
PCSR = 01H  
2) In PCM mode 1, with a frame consisting of 48 time slots, the following timing  
relationship between the framing signal and the data signals is required:  
1
PFS  
PMOD : PSM = 1  
0
Start of Internal Frame  
PDC  
TxD#  
BNU  
PCSR : URE = 1  
Required  
Time-Slot/Bit  
Offset in  
381  
382  
383  
384  
Bit 0  
1
2
3
Bit 3  
Bit 2  
Bit 1  
Bit 7  
Bit 6  
Bit 5  
Upstream  
Direction  
Time-Slot 47  
Time-Slot 0  
Required  
1
2
3
4
5
6
Time-Slot/Bit  
Offset in  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Downstream  
Direction  
Time-Slot 0  
PCSR : DRE = 1  
RxD#  
BND  
ITT08042  
Figure 27  
Timing for PCM Frame Offset of Example 2  
Semiconductor Group  
97  
 
PEB 2055  
PEF 2055  
Application Hints  
The PCM interface shall be clocked with a PDC having twice the frequency of the data  
rate i.e. 6144 kHz. Since the rising edge of PFS occurs a little bit before the rising edge  
of PDC i.e. the set-up and hold times with respect to the rising PDC are met, it is possible  
to select the rising PDC edge for sampling the PFS signal (PMOD:PSM = 1). In this case  
the 1st bit of the internal framing structure (according to figure 27) will represent time  
slot 47, bit 1 (383rd bit) in upstream and time slot 0, bit 5 (3rd bit) in downstream direction  
of the external frame (according to figure 25). The values to be programmed to the  
POFD, POFD and PCSR can now be determined as follows:  
With BND = 3, BNU = 383 and BPF = 384:  
OFD9 … 1 = (BND – 33 + BPF)mod BPF = (3 – 33 + 384)mod 384 = 354D = 1 0110 0010B  
OFU9 … 1 = (BNU + 47)mod BPF = (383 + 47)mod 384 = 46D = 0001 0111 0B  
POFD = 1011 0001B = B1H,  
POFU = 1000 1111B = 17H  
With URE = 1 and DRE = 1:  
PCSR = 0001 0001B = 11H,  
PCM Receive Line Selection PMOD:AIS1 … AIS0  
The PCM transmit line of a given logical port (as it is used for programming the switching  
function) is always assigned to a dedicated physical transmit pin, e.g. in PCM mode 1,  
pin TxD2 carries the PCM data of logical port 1.  
In receive direction however, an assignment between logical and physical ports can be  
made in PCM modes 1 and 2. This selection is programmed via the Alternative Input  
Selection bits 1 and 0 (AIS1, AIS0) in the PMOD register.  
In PCM mode 0, AIS1 and AIS0 should both be set to 0.  
In PCM mode 1, AIS0 selects between receive lines RxD0 and RxD1 for logical port 0  
and AIS1 between the receive lines RxD2 and RxD3 for logical port 1.  
In PCM mode 2, AIS1 selects between the receive lines RxD2 and RxD3, the setting of  
AIS0 is don’t care.  
The state of the AIS# bits is furthermore put out via the TSC# pins and can thus be used  
to control external circuits (drivers, relays … ).  
Semiconductor Group  
98  
PEB 2055  
PEF 2055  
Application Hints  
Table 13 shows the function taken on by each of the PCM interface pins, depending on  
the PCM mode and the values programmed to AIS1 and AIS0.  
Table 13  
PCM  
Port 0  
Port 1  
Port 2  
Port 3  
Mode  
RxD0  
TxD0 TSC0 RxD1  
OUT0 TSC0 IN1  
TxD1 TSC1 RxD2  
OUT1 TSC1 IN2  
TxD2 TSC2 RxD3  
OUT2 TSC2 IN3  
TxD3 TSC3  
OUT3 TSC3  
0
1
IN0  
IN0 for OUT0 TSC0 IN0 for high Z AIS0  
IN1 for OUT1 TSC1 IN1 for high Z AIS1  
AIS0=1  
AIS0=0  
AIS1=1  
AIS1=0  
2
OUT  
TSC  
high Z AIS0  
IN for  
undef. undef. IN for high Z AIS1  
AIS1=1  
AIS1=0  
Figure 28 shows the correlation between physical and logical PCM ports for PCM  
modes 0, 1, 2, 3:  
R
EPIC  
Logical Ports:  
Physical  
Pins:  
EPIC R  
TxD0  
TSC0  
RxD0  
TxD1  
TSC1  
RxD1  
TxD2  
TSC2  
RxD2  
TxD3  
TSC3  
RxD3  
OUT0  
Logical Ports:  
Physical  
Pins:  
TSC0  
IN0  
TxD0  
OUT0  
TSC0  
RxD0  
OUT1  
TSC1  
IN1  
TSC0  
EPIC R  
1
0
Logical Ports:  
Physical  
Pins:  
IN0  
RxD1  
TSC1  
TxD0  
PMOD:  
AIS0  
OUT1  
OUT2  
TSC2  
IN2  
OUT  
TxD2  
TSC0  
RxD2  
TSC  
TSC2  
RxD2  
1
0
TSC1  
IN  
1
0
RxD3  
TSC3  
OUT3  
TSC3  
IN3  
PMOD:  
AIS1  
IN1  
RxD3  
TSC3  
TSC1  
PMOD:  
AIS1  
PMOD:  
AIS0  
PCM Mode 0  
PCM Mode 1  
PCM Mode 2  
ITS09545  
Figure 28  
Correlation between Physical and Logical PCM Ports  
Semiconductor Group  
99  
 
 
PEB 2055  
PEF 2055  
Application Hints  
PCM Input Comparison PMOD:AIC1 … AIC0  
If the PCM input comparison is enabled, the EPIC checks the contents of two PCM  
receive lines (physical ports) against each other for mismatches. (Also refer to  
chapter 5.8.2).  
The comparison function is operational in all PCM modes, a redundant PCM line which  
can be switched over to by means of the PMOD:AIS bits is of course only available in  
PCM modes 1and 2.  
AIC0 set to logical 1 enables the comparison function between RxD0 and RxD1.  
AIC1 set to logical 1 enables the comparison function between RxD2 and RxD3.  
AIC1, AIC0 set to logical 0 disables the respective comparison function.  
PCM Standby Mode OMDR:PSB  
In standby mode (OMDR:PSB = 0), the PCM interface output pins TxD0 … 3 are set to  
high impedance and those (TSC#) pins which are actually used as tristate control signals  
are set to logical 1 (inactive).  
Note that the internal operation of the EPIC is not affected in standby mode, i.e. the  
received PCM data is still written into the downstream data memory and may still be  
processed by the EPIC (switched to the CFI or to the µP, compared with other input line,  
etc.)  
In operational mode (OMDR:PSB = 1), the PCM output pins transmit the contents of the  
upstream data memory data field or may be set to high impedance via the data memory  
tristate field (refer to chapter 5.3.3.2).  
Semiconductor Group  
100  
PEB 2055  
PEF 2055  
Application Hints  
PCM Test Loop OMDR:PTL  
The PCM test loop function can be used for diagnostic purposes if desired. If however a  
“simple” CFI to CFI connection (CFI PCM CFI loop) shall be established, it is  
recommended to program the PCM loop in the control memory (refer to  
chapter 5.4.3.1).  
If OMDR:PTL is set to logical 1, the test loop is enabled i.e. the physical transmit pins  
TxD# are internally connected to the corresponding physical receive pins RxD#, such  
that data transmitted over TxD# are internally looped back to RxD# and data externally  
received over RxD# are ignored. The TxD# pins still output the contents of the upstream  
data memory according to the setting of the tristate field.  
Note: This loop back function can only work if the upstream and downstream bit shifts  
match and if the port assignment (PMOD:AIS1 … 0) is such that a logical  
transmitter is looped back to a logical receiver (e.g. the PTL loop cannot work in  
PCM mode 2!).  
For normal operation OMDR:PTL should be set to logical 0 (test loop disabled).  
Figure 29 illustrates the effect of the PTL bit:  
EPIC R  
PCM Interface  
From Upstream  
TxD#  
Data Memory  
1
To Downstream  
Data Memory  
0
RxD#  
OMDR : PTL  
ITS09546  
Figure 29  
Effect of the OMDR:PTL Bit  
Semiconductor Group  
101  
 
PEB 2055  
PEF 2055  
Application Hints  
5.2.2  
Configurable Interface Configuration  
5.2.2.1 CFI Interface Signals  
The configurable interface signals are summarized in the table below:  
Table 14  
Pin No. Symbol  
I: Input  
Function  
O: Output  
40  
41  
42 1)  
43 1)  
DD0/SIP0 O/IO  
DD1/SIP1 O/IO  
DD2/SIP2 O/IO  
DD3/SIP3 O/IO  
Data downstream outputs in CFI modes 0, 1 and 2  
(PCM and IOM applications).  
Bidirectional serial interface ports in CFI mode 3  
(SLD application).  
Tristate or open drain output drivers selectable  
(OMDR:COS).  
38  
37  
36 1)  
35 1)  
DU0/SIP4 I/IO  
DU1/SIP5 I/IO  
DU2/SIP6 I/IO  
DU3/SIP7 I/IO  
Data upstream inputs in CFI modes 0, 1 and 2  
(PCM and IOM applications).  
Bidirectional serial interface ports in CFI mode 3  
(SLD application).  
Tristate or open drain output drivers for SIP lines  
selectable (OMDR:COS).  
34  
33  
FSC  
DCL  
I or O  
I or O  
Frame synchronization input (CMD1:CSS = 1) or  
output (CMD1:CSS = 0).  
Data clock input (CMD1:CSS = 1) or output  
(CMD1:CSS = 0).  
1) Only EPIC-1  
5.2.2.2 CFI Registers  
The characteristics at the configurable interface (timing, modes of operation, etc. … ) are  
programmed in the 6 CFI interface registers and the Operation Mode Register OMDR.  
The function of each bit is described in chapter 5.2.2.3. For addresses refer to  
chapter 4.1.  
CFI Mode Register 1  
read/write  
reset value:  
00H  
bit 7  
bit 0  
CMD1  
CCS  
CSM  
CSP1  
CSP0  
CMD1 CMD0  
CIS1  
CIS0  
Semiconductor Group  
102  
PEB 2055  
PEF 2055  
Application Hints  
CFI Mode Register 2  
read/write  
reset value:  
00H  
bit 7  
bit 0  
CMD2  
FC2  
FC1  
FC0  
COC  
CXF  
CRR  
CBN9  
CBN8  
CFI Bit Number Register  
read/write  
reset value:  
FFH  
bit 0  
bit 7  
CBNR  
CBN7  
CBN6  
CBN5  
CBN4  
CBN3  
CBN2  
CBN1  
CBN0  
CFI Time Slot Adjustment Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
CTAR  
0
TSN6  
TSN5  
CDS1  
SC21  
PSB  
TSN4  
TSN3  
TSN2  
TSN1  
TSN0  
CFI Bit Shift Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
CBSR  
0
CDS2  
CDS0  
CUS3  
CUS2  
CUS1  
CUS0  
CFI Bit Subchannel Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
CSCR  
SC31  
SC30  
SC20  
SC11  
SC10  
SC01  
SC00  
Operation Mode Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
OMDR  
OMS1 OMS0  
PTL  
COS  
MFPS  
CSB  
RBS  
Semiconductor Group  
103  
PEB 2055  
PEF 2055  
Application Hints  
5.2.2.3 CFI Characteristics  
In the following the configurable interface characteristics that can be programmed in the  
CFI registers are explained in more detail.  
CFI Mode CMD1:CMD1, CMD0  
The CFI mode primarily defines the actual number of CFI ports that can be used for  
switching purposes (logical ports). 1, 2 or 4 duplex or 8 bidirectional logical CFI ports can  
be selected. Since the channel capacity of the EPIC is constant (128 channels/direction),  
the CFI mode also influences the maximum possible data rate.  
In each CFI mode a reference clock (RCL) of a specific frequency is required. This clock  
may be derived from the PCM clock signal PDC (CMD1:CSS = 0) or from the DCL signal  
(CMD1:CSS = 1). Also refer to figure 30 and figure 31.  
Table 15 states the specific characteristics of each CFI mode.  
(DR = CFI data rate, N = number of 8 bit time slots in PCM frame, du = duplex port,  
bi = bidirectional port).  
Table 15  
CMD1 CMD0 CFI  
Number  
CFI Data Min. Required Necessary DCL Output  
Mode (Label) of  
Logical  
Rate  
[kbit/s]  
CFI DR  
[kbit/s]  
relative to  
PCM Data  
Rate  
Reference Frequencies  
Clock  
(RCL)  
CMD1:  
CSS = 0  
Ports  
min. max.  
1
0
0
1
1
0
1
0
3
0
1
2
8 bi (0 … 7) 128  
4 du (0 … 3) 128  
2 du (0 … 1) 128  
1024 16N/3  
4 × DR  
2 × DR  
DR  
DR, 2 × DR  
DR, 2 × DR  
DR  
2048 32N/3  
4096 64N/3  
8192 64N/3  
1 du  
128  
0.5 × DR  
DR  
Note: The label is used to specify a CFI port when programming a switching function. It  
should not be confused with the physical port number which refers to actual  
hardware pins. The relationship between logical and physical port numbers is  
given in table 19 and is illustrated in figure 46.  
Semiconductor Group  
104  
 
 
PEB 2055  
PEF 2055  
Application Hints  
Important Note  
It should be noticed that there are some restrictions concerning the PCM to CFI data rate  
ratio. If the CFI data rate is chosen higher than the PCM data rate, no restrictions apply.  
If however the CFI data rate is lower than the PCM data rate, a minimum CFI date rate  
relative to the PCM data rate must be maintained (refer also to examples below).  
Another important restriction is, that the number of bits per CFI frame must always be  
modulo 16.  
Examples  
If the PCM frame consists of 32 time slots (2.048 Mbit/s), the minimum possible CFI data  
rate in CFI mode 0 is (32 × 32)/3 = 341.3 kbit/s or if rounded to an integer number of time  
slots 344 kbit/s. It is thus not possible to have an IOM-1 interface with 256 kbit/s together  
with a 2.048 Mbit/s PCM interface in CFI mode 0. If instead the PCM frame consists of  
24 time slots (1.536 Mbit/s), the IOM-1 data rate of 256 kbit/s is feasible since  
(24 × 32)/3 = 256 kbit/s.  
CFI Clock and Framing Signal Source CMD1:CSS  
The PCM interface is always clocked and synchronized by the PDC and PFS input  
signals. The configurable interface however can be clocked and synchronized either by  
signals internally derived from PDC and PFS or it can be clocked and synchronized by  
the externally applied DCL and FSC input signals.  
If PDC and PFS are selected as clock and framing signal source (CMD1:CSS = 0),  
the CFI reference clock CRCL is obtained out of PDC after division by 1, 1.5 or 2  
according to the prescaler selection (CMD:CSP1 … 0). The CFI frame structure is  
synchronized by the PFS input signal. The EPIC generates DCL and FSC as output  
signals which may be specified by CMD2:COC (DCL clock rate) and CMD2:FC2 … 0  
(FSC pulse form). This mode should be selected whenever the required CFI data rate  
can be obtained out of the PCM clock source using the internal prescalers. An overview  
of the different possibilities to generate the PCM and CFI data and clock rates for  
CMD1:CSS = 0 is given in figure 30.  
Semiconductor Group  
105  
PEB 2055  
PEF 2055  
Application Hints  
R
EPIC  
CFI Mode  
2
1
0
3
2
Internal Reference  
Clock (RCL)  
CMD1 : CSP1, 0  
M
PDC  
CMD2 : COC  
U
X
1.5  
CFI Mode  
CRCL  
2
1
0
3
2
PMOD : PCR  
M
U
DCL  
FSC  
2
4
X
*
x2  
M
U
X
M
U
X
* Only CFI  
Modes 0 and 3  
2
CMD2 : FC2 ...0  
Bit Shift  
CTAR  
PFS  
FC Modes 0-7  
CBSR: CDS2...0  
Bit Shift  
POFU  
POFD  
PCSR  
CFI Frame Sync.  
CFI Data Rate  
PCM Frame Sync.  
PCM Data Rate  
C
F
I
P
C
M
ITS09547  
Figure 30  
EPIC® Clock Sources for the CFI and PCM Interfaces if CMD1:CSS = 0  
If DCL and FSC are selected as clock and framing signal source (CMD1:CSS = 1),  
the CFI reference clock CRCL is obtained out of the DCL input signal after division by 1,  
1.5 or 2 according to the prescaler selection (CMD1:CSP1 … 0). The CFI frame  
structure is synchronized by the FSC input signal. Note that although the frequency and  
phase of DCL and FSC may be chosen almost independently with respect to the  
frequency and phase of PDC and PFS, the CFI clock source must still be synchronous  
to the PCM interface clock source i.e. the two clock sources must always be derived from  
one master clock. This mode must be selected if it is impossible to derive the required  
CFI data rate from the PCM clock source. An overview of the different possibilities to  
generate the PCM and CFI data and clock rates for CMD1:CSS = 1 is given in figure 31.  
Semiconductor Group  
106  
PEB 2055  
PEF 2055  
Application Hints  
EPIC R  
CFI Mode  
2
2
1
0
3
Internal Reference  
Clock (RCL)  
PMOD : PCR  
CMD : CSP1, 0  
M
M
U
X
PDC  
PFS  
DCL  
FSC  
U
X
1.5  
CRCL  
CFI Mode  
2
2
2
1
0
3
Bit Shift  
CTAR  
2
4
Bit Shift  
POFU  
POFD  
PCSR  
CBSR: CDS2...0  
CFI Frame Sync.  
CFI Data Rate  
PCM Frame Sync.  
PCM Data Rate  
C
F
I
P
C
M
ITS09548  
Figure 31  
EPIC® Clock Sources for the CFI and PCM Interfaces if CMD1:CSS = 1  
CFI Clock Source Prescaler CMD1:CSP1 … 0  
The CFI clock source PDC (CMD1:CSS = 0) or DCL (CMD1:CSS = 1) can be divided by  
a factor of 1, 1.5 or 2 in order to obtain the CFI reference clock CRCL (see table 16).  
Note that in CFI mode 2, the frequency of RCL is only half the CFI data rate.  
Table 16  
CSP1  
CSP0  
Prescaler Divisor  
0
0
1
1
0
1
0
1
2
1.5  
1
not allowed  
Semiconductor Group  
107  
 
PEB 2055  
PEF 2055  
Application Hints  
Figure 32 shows the relationship between the DCL input and the generated RCL for the  
different prescaler divisors in case CMD1:CSS = 1:  
Conditions:  
FSC  
FSC  
DCL  
CMD1 : CSM = 1  
CMD1 : CSM = 0  
RCL  
RCL  
CFI Modes 0, 1 and 3  
CFI Mode 2  
RCL  
RCL  
CFI Modes 0, 1 and 3  
CFI Mode 2  
RCL  
RCL  
CFI Modes 0, 1 and 3  
CFI Mode 2  
ITT08047  
Figure 32  
Clock Signal Timing for the Different Prescaler Divisors if CMD1:CSS = 1  
CFI Clock Output Rate CMD2:COC  
This feature applies only if the configurable interface is clocked and synchronized via the  
PCM interface clock and framing signals (PDC, PFS), i.e. if CMD1:CSS = 0.  
In this case the EPIC delivers an output clock signal at pin DCL with a frequency identical  
to or double the selected CFI data rate:  
For CMD2:COC = 0, the frequency of DCL is identical to the CFI data rate  
(all CFI modes)  
For CMD2:COC = 1, the frequency of DCL is twice the CFI data rate  
(CFI modes 0 and 3 only!)  
Semiconductor Group  
108  
 
PEB 2055  
PEF 2055  
Application Hints  
Figure 33 shows the relationship between the PFS, PDC, RCL and DCL signals in the  
different CFI modes.  
Conditions:  
PFS  
PFS  
PDC  
CMD1 : CSM = 1/PMOD : PSM = 1  
CMD1 : CSM = 0/PMOD : PSM = 0  
RCL  
RCL  
DCL  
DCL  
DCL  
CFI Modes 0,1 and 3  
CFI Mode 2  
CFI Mode 0, CMD2 : COC = 1  
CFI Modes 1 and 2  
CFI Mode 0, CMD2 : COC = 0  
CFI Mode 3, CMD2 : COC = 1  
CFI Mode 3, CMD2 : COC = 0  
RCL  
RCL  
DCL  
DCL  
DCL  
CFI Modes 0,1 and 3  
CFI Mode 2  
CFI Mode 0, CMD2 : COC = 1  
CFI Modes 1 and 2  
CFI Mode 0, CMD2 : COC = 0  
CFI Mode 3, CMD2 : COC = 1  
CFI Mode 3, CMD2 : COC = 0  
RCL  
RCL  
DCL  
DCL  
DCL  
CFI Modes 0,1 and 3  
CFI Mode 2  
CFI Mode 0, CMD2 : COC = 1  
CFI Modes1 and 2  
CFI Mode 0, CMD2 : COC = 0  
CFI Mode 3, CMD2 : COC = 1  
CFI Mode 3, CMD2 : COC = 0  
ITT08048  
Figure 33  
Clock Signal Timing for the Different Prescaler Divisors if CMD1:CSS = 0  
Semiconductor Group  
109  
 
PEB 2055  
PEF 2055  
Application Hints  
CFI Framing Signal Output Control CMD2:FC2 … 0  
This feature applies only if the configurable interface is clocked and synchronized via the  
PCM interface clock and framing signals (PDC, PFS), i.e. if CMD1:CSS = 0.  
In this case the EPIC delivers an output framing signal at pin FSC with a programmable  
pulse width and position.  
Note that the up- and downstream CFI frame position relative to the FSC output is not  
affected by the setting of the CTAR and CBSR:CDS2 … 0 register bits.  
Table 17 summarizes the 7 possible FSC Control (FC) modes:  
Table 17  
FC2 FC1 FC0 FC  
Mode  
Main Applications  
Notes  
0
0
0
0
1
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
0
IOM-1 multiplexed (burst) mode SBC, IBC, IEC-T  
General purpose  
General purpose  
1
2
3
4
5
6
General purpose  
Special SLD application  
reserved  
2 ISAC-S per SLD port  
IOM-2, IOM-1 or SLD modes  
Standard IOM-2 setting;  
no Superframes  
generated  
1
1
1
7
Software timed multiplexed  
IOM-2 applications  
Standard IOM-2 setting;  
Superframes generated  
Semiconductor Group  
110  
 
PEB 2055  
PEF 2055  
Application Hints  
Figure 34 and figure 35 show the position of the FSC pulse relative to the CFI frame:  
Last Time-Slot of a Frame  
Time-Slot 0  
Conditions:  
CFI Frame  
RCL  
CFI Mode 0; CMD2 : COC = 1  
CFI Modes 1, 2; CMD2 : COC = 0  
DCL  
DCL  
DCL  
CFI Mode 0; CMD2 : COC = 0  
CFI Modes 3; CMD2 : COC = 1  
CFI Modes 3; COC = 0  
CMD2 : FC2 ...0 = 011  
(FC Mode 3)  
FSC  
FSC  
FSC  
FSC  
FSC  
CMD2 : FC2 ...0 = 010  
(FC Mode 2)  
CMD2 : FC2 ...0 = 000  
(FC Mode 0)  
CMD2 : FC2 ...0 = 001  
(FC Mode 1)  
CMD2 : FC2 ...0 = 110  
(FC Mode 6)  
ITT08049  
Figure 34  
Position of the FSC Signal for FC Modes 0, 1, 2, 3 and 6  
Time-Slot  
Conditions:  
0
1
2
3
4
5
CFI Frame  
FSC  
CMD2 : FC2 ... 0 = 110 (FC mode 6)  
CMD2 : FC2 ... 0 = 100 (FC mode 4)  
FSC  
RCL  
ITT08050  
Figure 35  
Position of the FSC Signal for FC Modes 4 and 6  
Semiconductor Group  
111  
 
 
PEB 2055  
PEF 2055  
Application Hints  
Application Examples of the Different FC Modes  
FC Mode 0  
FC mode 0 applies for IOM-1 multiplexed mode applications, i.e. for IOM-1 interfaces  
with 2.048 Mbit/s data rate. Accommodated layer-1 devices: SBC (PEB 2080),  
IBC (PEB 2095), IEC-T (PEB 20901/20902), …  
In IOM-1 mux. mode, the frame is synchronized with a negative pulse with a duration of  
one DCL period which marks bit number 251. The bits are transmitted with the falling  
clock edge and received with the rising clock edge.  
Required register setting: CMD1 = 0XXX0000B, CMD2 = 1CH, CBNR = FFH,  
CTAR = XXH, CBSR = X0H.  
Figure 36 shows the relationship between FSC, DCL, DD# and DU#:  
FSC  
DCL  
DD#  
DU#  
TS31, Bit 4  
TS31, Bit 3  
TS31, Bit 2  
TS31, Bit 1  
TS31, Bit 0  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
TS31, Bit 5  
TS31, Bit 4  
TS31, Bit 3  
TS31, Bit 2  
TS31, Bit 1  
TS31, Bit 0  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
ITT08051  
Figure 36  
Multiplexed IOM®-1 Interface Signals  
FC Mode 1  
FC mode 1 is similar to FC mode 0. The FSC pulse is shifted by half a RCL period to the  
right compared to FC mode 0. It can be used for general purposes.  
FC Mode 2  
FC mode 2 is similar to FC mode 3. The FSC pulse is shifted by half a RCL period to the  
left compared to FC mode 3. It can be used for general purposes.  
Semiconductor Group  
112  
 
PEB 2055  
PEF 2055  
Application Hints  
FC Mode 3  
FC mode 3 can be used for IOM-2 applications, but it should be noted that some IOM-2  
layer-1 transceivers will interpret an FSC pulse of only one DCL period as a superframe  
marker (e.g. SBCX PEB 2081, IEC-Q PEB 2091, … ), and it is not allowed to provide a  
superframe marker in every frame. For these applications it is recommended to use  
either FC mode 6 or FC mode 7.  
FC Mode 4  
FC mode 4 applies for special SLD applications like 2 ISAC-S devices connected to one  
SIP line. Usually each SIP line carries the two 64 kbit/s B channels followed by a feature  
control and a signaling channel. The feature control and signaling channels however are  
not required for all applications. This is, for example, the case if a digital subscriber circuit  
(S- or U- layer-1 transceiver) is connected via an ISDN Communication Controller  
(ICC PEB 2070) to the EPIC. The task of the ICC is to handle the D-channel and to  
switch the B1 and B2 channels from the SLD to the IOM-1 interface. The capacity of such  
an SLD line card can be doubled if the unused time slots for the feature control and  
signaling channels are also used as 64 kbit/s B channels. This is possible if the  
additionally connected ICC (or ISAC-S) is synchronized with an FSC that is delayed by  
2 time slots i.e. the rising FSC edge is at the beginning of time slot 2 instead of 0. The  
CFI time slots 2, 3, 6 and 7 can then be programmed as normal B channels within the  
EPIC instead of being programmed as feature control and signaling channels.  
FC Mode 6  
This is the most often used type of FSC signal, because it covers the standard IOM-1,  
IOM-2 and SLD applications. The rising edge of FSC marks time slot 0, bit 7 of the CFI  
frame.  
The pulse width is 32 bits or 4 time slots, i.e. the FSC is symmetrical (duty cycle 1:1) if  
the CFI frame consists of 8 time slots (SLD), and the FSC is high during the first IOM-2  
channel if the CFI frame consists of 32 time slots (IOM-2).  
Semiconductor Group  
113  
PEB 2055  
PEF 2055  
Application Hints  
Required register setting for IOM-2:  
CMD1 = 0XXX0000B, CMD2 = D0H, CBNR = FFH, CTAR = XXH, CBSR = X0H.  
Figure 37 shows the relationship between FSC, DCL, DD# and DU#:  
FSC  
DCL  
DD#  
DU#  
TS31, Bit 0  
TS0,Bit 7  
TS0,Bit 6  
TS0,Bit 5  
TS0,Bit 4  
TS0,Bit 3  
TS0,Bit 2  
TS0,Bit 1  
TS0,Bit 0  
TS31, Bit 1  
TS31, Bit 0  
TS0,Bit 7  
TS0,Bit 6  
TS0,Bit 5  
TS0,Bit 4  
TS0,Bit 3  
TS0,Bit 2  
TS0,Bit 1  
TS0,Bit 0  
ITT08052  
Figure 37  
IOM®-2 Interface Signals  
Required register setting for SLD:  
CMD1 = 0XXX1100B, CMD2 = D0H, CBNR = 1FH, CTAR = XXH, CBSR = X0H.  
Figure 38 shows the relationship between FSC, DCL and SIP#:  
FSC  
RCL  
DCL  
SIP#  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
TS0, Bit 3  
(OUT)  
SIP#  
(IN)  
TS7, Bit 4  
TS7, Bit 3  
TS7, Bit 2  
TS7, Bit 1  
TS7, Bit 0  
ITT08053  
Figure 38  
SLD Interface Signals  
Semiconductor Group  
114  
 
 
PEB 2055  
PEF 2055  
Application Hints  
FC Mode 7  
FC mode 7 is intended for IOM-2 line cards to synchronize the multiframe structure  
among several S- or Uk-interface transceivers. The layer-1 multiframe is reset by an FSC  
pulse having a width of at most, one DCL period. Between the multiframe reset pulses,  
FSC pulses with a width of at least two DCL periods must be applied. Devices which  
support this option are for example the OCTAT-P (PEB 2096-H), QUAT-S  
(PEB 2084-H), SBCX (PEB 2081), and the IEC-Q (PEB 2091).  
FC mode 7 is a combination of FC modes 3 and 6. The timer register TIMR must be  
loaded with the required multiframe period (e.g. 5 ms for the S-interface or 12 ms for the  
Uk-interface). When the timer is started with CMDR:ST, a cyclic multiplexing process is  
started: whenever the timer expires, the frame signal has the pulse shape of FC mode 3  
during one frame. For all the other frames the FSC signal has the pulse form of FC  
mode 6.  
After setting the CMDR:ST bit, the inverted value of TVAL is loaded to the timer and the  
timer is incremented as soon as time slot 3 is passed (i.e. the FSC high phase is passed  
which lasts for 4 TSs in FC mode 6) and then every 250 µs.  
When the timer expires (timer value = 0), an interrupt is generated immediately and the  
next FSC pulse has the shape of FC mode 3.  
Figure 39 illustrates this behavior for a timer value of TVAL6 … 0 = 0000001.  
n
n + 1  
n + 2  
n + 3  
n + 4  
n + 5  
n + 6  
n + 7  
n + 8  
CFI Frame  
FSC  
FC Mode 7  
Timer Loaded  
CMFR: ST = 1  
Timer  
Incremented  
Timer  
Expired  
Timer  
Incremented  
Timer  
Expired  
ITT08054  
Figure 39  
FSC Signal in FC Mode 7  
Note: If the timer is stopped, the generated pulse form is the one of FC mode 6.  
Timer value examples:  
Required timer value for 5 ms period: TIMR:TVAL6 … 0 = 010011B, e.g. TIMR = 13H  
Required timer value for 12 ms period: TIMR:TVAL6 … 0 = 101111B, e.g TIMR = 2FH  
Semiconductor Group  
115  
 
PEB 2055  
PEF 2055  
Application Hints  
CFI Bit Number CMD2, CBNR:CBN9 … CBN0  
The CFI data rate is determined by the reference clock RCL and the CFI mode selected  
by CMD1:CMD1 … 0. The number of bits which constitute a CFI frame can be derived  
from this data rate by division of 8000 (8 kHz frame structure). If the CFI interface is for  
example operated at 2.048 Mbit/s, the frame would consists of 256 bits or 32 time slots.  
This number of bits must be programmed to CMD2,CBNR:CBN9 … 0 as indicated  
below. Note that the formula is valid for all CFI modes:  
CBN9 … 0 = number of bits – 1  
Examples  
A CFI frame consisting of 64 time slots would require a setting of  
CBN9 … 0 = 64 × 8 – 1 = 511D = 01 1111 1111B  
A CFI frame consisting of 48 time slots would require a setting of  
CBN9 … 0 = 48 × 8 – 1 = 383D = 01 0111 1111B  
CFI Synchronization Mode CMD1:CSM  
The CFI interface can either be synchronized via the PFS pin (CMD1:CSS = 0), or via  
the FSC pin (CMD1:CSS = 1). A transition from low to high of either PFS or FSC  
synchronizes the CFI frame. The PFS (FSC) signal is internally sampled with the PDC  
(DCL) clock:  
If CSM is set to logical 0, the PFS/FSC signal is sampled with the falling clock edge of  
PDC/DCL, if set to logical 1, the PFS/FSC signal is sampled with the rising clock edge  
of PDC/DCL.  
If CMD1:CSS is set to logical 0 (CFI clocks are internally derived from the PCM clocks),  
then CMD1:CSM should be equal to PMOD:PSM.  
If CMD1:CSS is set to logical 1 (CFI clock signals are inputs), then CMD1:CSM should  
be selected such that stable low and high phases of the FSC signal can be detected,  
meeting the set-up (TFS) and hold (TFH) times with respect to the programmed DCL clock  
edge.  
The high phase of the PFS/FSC pulse may be of arbitrary length, however it must be  
assured that it is sampled low at least once before the next framing pulse.  
The relationship between the framing and clock signals (PFS, FSC, PDC, DCL and RCL)  
for the different modes of operation is illustrated in figures 32 and 33.  
Note: In case DCL and FSC are selected as inputs (CMD1:CSS = 1), FSC must always  
be synchronized with the positive edge of DCL (CMD1:CSM = 1). Otherwise, an  
IOM-2 compatible timing cannot be installed by means of a bit shift (When the  
negative edge is used for synchronization the internal frame start is delayed by  
one DCL clock. In double rate mode a bit shift of half a bit cannot be adjusted).  
Anyway, if the rising edges of DCL and FSC do not meet the frame setup time TFS,  
Semiconductor Group  
116  
PEB 2055  
PEF 2055  
Application Hints  
additional hardware must delay the frame signal to enable a synchronization with  
the positive edge of DCL. Figure 40 gives a suggestion of how to adapt the  
external timing.  
EPIC R  
J-K Flip-Flop e.g. 74HC112  
+5 V  
J
Q
J
Q
Q
FSC  
PR  
+5 V  
PR  
SYNC  
CLR  
K
CLR  
K
Q
CLK  
DCL  
DIN  
(DU#)  
(DD#)  
DOUT  
CLK  
SYNC  
DOUT  
DIN  
1st Bit  
2nd Bit  
3rd Bit  
4th Bit  
5th Bit  
1st Bit  
2nd Bit  
3rd Bit  
4th Bit  
5th Bit  
FSC  
Rising FSC edge marks 2nd Bit of frame  
ITS08055  
Figure 40  
Circuit for Delaying the Framing Signal at the CFI Interface  
Semiconductor Group  
117  
 
PEB 2055  
PEF 2055  
Application Hints  
CFI Bit Timing and Bit Shift CMD2, CTAR, CBSR  
The position of the CFI frame can be shifted relative to the CFI frame synchronization  
pulse using the CFI Time slot Adjustment Register CTAR and the CFI Bit Shift Register  
CBSR. This shifting can be performed simultaneously for up- and downstream directions  
with a one bit resolution by up to a whole frame. The upstream frame can additionally be  
shifted relative to the downstream frame by up to 15 bits. Furthermore, the polarity of the  
clock edge (CRCL) used for transmitting and sampling the data can be programmed in  
the CMD2 register.  
Since the frame synchronization source of the configurable interface is either PFS (for  
CMD1:CSS = 0) or FSC (for CMD1:CSS = 1), the bit shift also refers to either the PFS  
or the FSC framing signal.  
Note: If PFS/PDC is selected as CFI sync/clock source, the time slot and bit shift  
values programmed to CTAR and CBSR:CDS2 … 0 affect both the CFI data lines  
and the CFI output framing signal FSC. The CFI frame together with the FSC  
signal can thus be shifted with respect to the PCM frame (PFS). The position of  
the CFI frame relative to the FSC output signal is not affected by these settings  
but is instead determined by the FSC framing control mode programmed to  
CMD2:FC2 … 0. The upstream CFI frame can, however, still be shifted relative to  
the downstream CFI frame with the CBSR:CUS3 … 0 bits.  
If FSC/DCL is selected as CFI sync/clock source, the time slot and bit shift functions  
affect the CFI frame with respect to the FSC framing input signal. In this case, the CFI  
frame start can be selected completely independently from the PCM frame start, it must  
only be assured that a phase relationship once established between the CFI and PCM  
frames is maintained all the time.  
Semiconductor Group  
118  
PEB 2055  
PEF 2055  
Application Hints  
CFI Time Slot Adjustment and Bit Shift  
If CBSR = 20H, the CFI framing signal (PFS if CMD1:CSS = 0 or FSC if CMD1:CSS = 1)  
marks bit 7 of the CFI time slot called TSN according to the following formula:  
CTAR:TSN6 … 0 = TSN + 2  
e.g. CTAR must be set to 02H if the framing signal should mark time slot 0, bit 7 (TS  
= 0). See examples.  
Note that the value of TSN may not exceed the actual number of time slots per CFI  
frame:  
TSN = [ – 2; I – 3], I = total number of time slots per CFI frame  
From the zero offset bit position (CBSR = 20H) the CFI frame (downstream and  
upstream) can be shifted by up to 5 bits to the left (within the time slot  
number TSN programmed in CTAR) and by up to 2 bits to the right (within the previous  
time slot N – 1) by programming the CBSR:CDS2 … 0 bits:  
Table 18  
CBSR:CDS2 … 0  
Time Slot #  
Marked Bit #  
Bit Shift  
000  
001  
010  
011  
100  
101  
110  
111  
TSN – 1  
TSN – 1  
TSN  
TSN  
TSN  
TSN  
TSN  
TSN  
1
0
7
6
5
4
3
2
2 bits to the right  
1 bit to the right  
no bit shift  
1 bit to the left  
2 bits to the left  
3 bits to the left  
4 bits to the left  
5 bits to the left  
The bit shift programmed to CBSR:CDS2 … 0 affects both the upstream and  
downstream frame position in the same way.  
If CBSR:CUS3 … 0 = 0000, the upstream frame is aligned to the downstream frame.  
With CBSR:CUS3 … 0 = 0001 to 1111, the upstream CFI frame can be shifted relative  
to the downstream frame by up to 15 bits to the left as indicated in figure 41.  
Semiconductor Group  
119  
 
PEB 2055  
PEF 2055  
Application Hints  
Conditions:  
CBSR:  
CUS3...0  
DD#  
DU#  
TS0, Bit 7 TS0, Bit 6 TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0  
0000  
TS0, Bit 7 TS0, Bit 6 TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0  
TS0, Bit 7 TS0, Bit 6 TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
DU#  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
1000  
1001  
1010  
1011  
1100  
1101  
1110  
1111  
TS0, Bit 7 TS0, Bit 6 TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6  
TS0, Bit 7 TS0, Bit 6 TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5  
TS0, Bit 7 TS0, Bit 6 TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4  
TS0, Bit 7 TS0, Bit 6 TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3  
TS0, Bit 6 TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2  
TS0, Bit 5 TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1  
TS0, Bit 4 TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1 TS1, Bit 0  
TS0, Bit 3 TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1 TS1, Bit 0  
TS0, Bit 2 TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1 TS1, Bit 0  
TS0, Bit 1 TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1 TS1, Bit 0  
TS0, Bit 0 TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1 TS1, Bit 0  
TS1, Bit 7 TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1 TS1, Bit 0  
TS1, Bit 6 TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1 TS1, Bit 0  
TS1, Bit 5 TS1, Bit 4 TS1, Bit 3 TS1, Bit 2 TS1, Bit 1 TS1, Bit 0  
ITT08056  
Figure 41  
CFI Upstream Bit Shifting  
Semiconductor Group  
120  
 
PEB 2055  
PEF 2055  
Application Hints  
CFI Bit Timing  
In CFI modes 0, 1 and 2, the rising or falling CRCL clock edge can be selected for  
transmitting and sampling the data.  
In CFI mode 3, the rising or falling CRCL clock edge can be selected for transmitting the  
data, the sampling of data however must always be done with the falling edge of CRCL  
(CRR = 0).  
If CMD2:CXF = 0 (CFI Transmit on Falling edge), the data is transmitted with the rising  
CRCL edge, if CXF = 1, the data is transmitted with the next following falling edge of  
CRCL.  
If CMD2:CRR = 0 (CFI Receive on Rising edge), the data is sampled with the falling  
CRCL edge, if CRR = 1, the data is sampled with the next following rising edge of CRCL.  
The relationship between the framing and clock signals and the CFI bit stream on DD#  
and DU# for CTAR = 02H and CBSR = 20H are illustrated in figure 42 and figure 43.  
Semiconductor Group  
121  
PEB 2055  
PEF 2055  
Application Hints  
Conditions:  
CMD1 : CSM = 0  
PMOD: PSM = 0  
PFS  
PFS  
RCL  
RCL  
CMD1 : CSM = 1  
PMOD: PSM = 1  
CFI Modes 0,  
1 and 3  
CFI Mode 2  
TS0,  
Bit 7  
TS0,  
Bit 6  
TS0,  
Bit 5  
TS0,  
Bit 4  
TS0,  
Bit 3  
TS0,  
Bit 2  
TS0,  
Bit 1  
TS0,  
Bit 0  
DD#  
CMD2 : CXF = 0  
TS0,  
Bit 7  
TS0,  
Bit 6  
TS0,  
Bit 5  
TS0,  
Bit 4  
TS0,  
Bit 3  
TS0,  
Bit 2  
TS0,  
Bit 1  
TS0,  
Bit 0  
DD#  
DU#  
CMD2 : CXF = 1  
CMD2 : CRR = 0  
TS0,  
Bit 7  
TS0,  
Bit 6  
TS0,  
Bit 5  
TS0,  
Bit 4  
TS0,  
Bit 3  
TS0,  
Bit 2  
TS0,  
Bit 1  
TS0,  
Bit 0  
DU#  
CMD2 : CRR = 1  
TS0,  
Bit 7  
TS0,  
Bit 6  
TS0,  
Bit 5  
TS0,  
Bit 4  
TS0,  
Bit 3  
TS0,  
Bit 2  
TS0,  
Bit 1  
TS0,  
Bit 0  
DD#  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
TS0, Bit 3 CMD2 : CXF = 0  
DD#  
DU#  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4 CMD2 : CXF = 1  
CMD2 : CRR = 0  
TS0, Bit 3  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
DU#  
CMD2 : CRR = 1  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
SIP#  
(OUT)  
TS0, Bit 7  
TS0, Bit 6  
CMD2 : CXF = 0  
SIP#  
(OUT)  
TS0, Bit 7  
TS0, Bit 6  
CMD2 : CXF = 1  
CMD2 : CRR = 0  
SIP#  
(IN)  
TS0, Bit 7  
TS0, Bit 6  
CMD2 :  
FSC2... 0 = 011  
FSC  
ITT08057  
Figure 42  
CFI Bit Timing with Respect to the Framing Signal PFS (CMD1:CSS = 0)  
Semiconductor Group  
122  
PEB 2055  
PEF 2055  
Application Hints  
Conditions:  
PFS  
PFS  
RCL  
RCL  
CMD1: CSM = 0  
CMD1: CSM = 1  
CFI Modes 0,  
1 and 3  
CFI Mode 2  
TS0,  
Bit 7  
TS0,  
Bit 6  
TS0,  
Bit 5  
TS0,  
Bit 4  
TS0,  
Bit 3  
TS0,  
Bit 2  
TS0,  
Bit 1  
TS0,  
Bit 0  
DD#  
CMD2 : CXF = 0  
TS0,  
Bit 7  
TS0,  
Bit 6  
TS0,  
Bit 5  
TS0,  
Bit 4  
TS0,  
Bit 3  
TS0,  
Bit 2  
TS0,  
Bit 1  
TS0,  
Bit 0  
DD#  
DU#  
CMD2 : CXF = 1  
CMD2 : CRR = 0  
TS0,  
Bit 7  
TS0,  
Bit 6  
TS0,  
Bit 5  
TS0,  
Bit 4  
TS0,  
Bit 3  
TS0,  
Bit 2  
TS0,  
Bit 1  
TS0,  
Bit 0  
DU#  
CMD2 : CRR = 1  
TS0,  
Bit 7  
TS0,  
Bit 6  
TS0,  
Bit 5  
TS0,  
Bit 4  
TS0,  
Bit 3  
TS0,  
Bit 2  
TS0,  
Bit 1  
TS0,  
Bit 0  
DD#  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
TS0, Bit 3 CMD2 : CXF = 0  
DD#  
DU#  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4 CMD2 : CXF = 1  
CMD2 : CRR = 0  
TS0, Bit 3  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
DU#  
CMD2 : CRR = 1  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
SIP#  
(OUT)  
TS0, Bit 7  
TS0, Bit 6  
CMD2 : CXF = 0  
CMD2 : CXF = 1  
SIP#  
(OUT)  
TS0, Bit 7  
TS0, Bit 6  
SIP#  
(IN)  
CMD2 : CRR = 0  
TS0, Bit 7  
TS0, Bit 6  
ITT08058  
Figure 43  
CFI Bit Timing with Respect to the Framing Signal FSC (CMD1:CSS = 1)  
Semiconductor Group  
123  
PEB 2055  
PEF 2055  
Application Hints  
Examples  
1) In CFI mode 0, with a frame consisting of 32 time slots, the following timing  
relationship between the framing signal source PFS and the data signals is required:  
Condition:  
1
CMD1: CSM = 1  
PMOD: PSM = 1  
PFS  
0
PDC/  
CRCL  
CFI Mode 0  
DD#  
DU#  
TS31, Bit 2  
TS0, Bit 6  
TS31, Bit 1  
TS0, Bit 5  
TS31, Bit 0  
TS0, Bit 4  
TS0, Bit 7  
TS0, Bit 3  
TS0, Bit 6  
TS0, Bit 2  
CMD2 : CXF = 1  
CMD2 : CRR = 0  
FSC  
DCL  
CMD2 : FC2 ...0 = 011  
CMD2 : COC = 0  
ITT08059  
Figure 44  
Timing Signals for CFI Bit Shift Example 1  
The framing signal source PFS shall mark CFI time slot 31, bit 1 in downstream direction  
and CFI time slot 0, bit 5 in upstream direction. The data shall be transmitted and  
sampled with the falling CRCL edge. The timing of the FSC and DCL output signals shall  
be as shown in figure 44. The PFS signal is sampled with the rising PDC edge.  
The following CFI register values result:  
Since PFS marks the downstream bit 1, the CBSR:CDS bits must be set to “000”,  
according to table 18.  
If the CBSR:CDS bits are set to “000”, PFS marks the time slot TSN – 1, according to  
table 18.  
PFS shall mark CFI time slot 31, i.e. TSN – 1 = 31, or  
TSN = 31 + 1 = (32)mod 32 = 0  
From this it follows that:  
CTAR:TSN6 … 0 = TSN + 2 = 0 + 2 = 2D = 0000010B; i.e. CTAR = 02H  
The upstream CFI frame shall be shifted by 4 bits to the left (TS31, bit 1 + 4 bits yields  
in TS0, bit 5).  
Semiconductor Group  
124  
 
PEB 2055  
PEF 2055  
Application Hints  
The CBSR:CUS bits must therefore be set to “0100”, according to figure 41.  
The complete value for CBSR is: CBSR = 04H  
Finally, the CMD2 register bits must be set to  
FC2 … 0 = 011, COC = 0, CXF = 1, CRR = 0, CBN9 … 8 = 00, i.e. CMD2 = 68H  
2) In CFI mode 0, with a frame consisting of 32 time slots, the following timing  
relationship between the framing signal source FSC and the data signals is required:  
1
FSC  
DCL  
DD#  
CMD1: CSM = 1  
CFI Mode 0  
0
Start of Internal Frame  
TS4, Bit 1  
CMD2 : CXF = 0  
Required  
Offset in  
Downstream  
Direction  
Bit 3  
Bit 2  
Bit 1  
Time-Slot 4  
Bit 0  
Bit 7  
Bit 6  
Bit 5  
Time-Slot 5  
Required  
Offset in  
Upstream  
Direction  
Bit 7  
Bit 6  
Bit 5  
Time-Slot 0  
Bit 4  
Bit 3  
Bit 2  
DU#  
CMD2 : CRR = 1  
TS0, Bit 5  
ITT08060  
Figure 45  
Timing Signals for CFI Bit Shift Example 2  
The framing signal source FSC shall mark CFI time slot 4, bit 1 in downstream direction  
and CFI time slot 0, bit 5 in upstream direction. The data shall be transmitted with the  
rising CRCL edge and sampled with the rising CRCL edge. The FSC signal shall be  
sampled with the rising DCL edge.  
The following CFI register values result:  
Since FSC marks the downstream bit 1, the CBSR:CDS bits must be set to “000”,  
according to table 18.  
If the CBSR:CDS bits are set to “000”, FSC marks the time slot TSN – 1, according to  
table 18.  
FSC shall mark CFI time slot 4, i.e. TSN – 1 = 4, or TSN = 4 + 1 = 5  
Semiconductor Group  
125  
PEB 2055  
PEF 2055  
Application Hints  
From this it follows that:  
CTAR:TSN6 … 0 = TSN + 2 = 5 + 2 = 7D = 0000111B; i.e. CTAR = 07H  
The upstream CFI frame shall be shifted by 28 bits to the right (ts 4, bit 1 - 28 bits yields  
in TS0, bit 5)  
Since it is not possible to shift the upstream frame with respect to the downstream frame  
by more than 15 bits when using the CBSR:CUS bits, the following trick must be used:  
The CBSR:CUS bits are set to “0100” to shift the frame by 4 bits to the left. The  
remaining shift to the right of 28 + 4 = 32 bits (equivalent to 4 time slots) can now be  
performed by renumbering the upstream CFI time slots in the software. This results in  
an offset of 4 time slots when addressing a CFI time slot via the Control Memory (CM):  
If CFI time slot N shall be switched (N refers to the external time slot numbering), the CM  
must be written with the CFI address (N + 4)mod 32  
.
If for example the upstream CFI time slot 0 of port 0 shall be switched to a PCM time slot,  
the CM address 88H (CFI p 0, TS4) must be used.  
The complete value for CBSR is: CBSR = 04H  
Finally the CMD2 register bits must be set to  
FC2 … 0 = XXX, COC = X, CXF = 0, CRR = 1, CBN9 … 8 = 00, i.e.: CMD2 = 04H  
CFI Receive Line Selection CMD1:CIS1 … CIS0  
The CFI transmit line of a given logical port (as it is used for programming the switching  
function) is always assigned to a dedicated physical transmit pin, e.g. in CFI mode 1, pin  
DD1 carries the CFI data of logical port 1.  
In receive direction however, an assignment between logical and physical ports can be  
made in CFI modes 1 and 2. This selection is programmed via the alternative input  
selection bits 1 and 0 (CIS1, CIS0) in the CMD1 register.  
In CFI mode 0 and 3, CIS1 and CIS0 should both be set to 0.  
In CFI mode 1, CIS0 selects between receive lines DU0 and DU2 for logical port 0 and  
CIS1 between the receive lines DU1 and DU3 for logical port 1.  
In CFI mode 2, CIS0 selects between the receive lines DU0 and DU2, CIS1 should be  
set to 0.  
Semiconductor Group  
126  
PEB 2055  
PEF 2055  
Application Hints  
Table 19 shows the function taken over by each of the CFI interface pins, depending on  
the CFI mode and the values programmed to CIS1 and CIS0.  
Table 19  
CFI  
Mode  
Port 0  
DD0  
Port 1  
DD1  
Port 2  
DD2  
Port 3  
DU3 DD3  
DU0  
DU1  
DU2  
0
1
IN0  
OUT0  
OUT0  
IN1  
OUT1 IN2  
OUT2 IN3  
OUT3  
high Z  
IN0  
IN1  
OUT1 IN0  
high Z IN1  
CIS0 = 0  
CIS1 = 0  
CIS0 = 1  
high Z IN  
CIS0 = 1  
I/O6  
CIS1 = 1  
high Z –  
2
IN  
CIS0 = 0  
OUT  
high Z  
I/O3  
3
I/O4  
I/O0  
I/O5  
I/O1  
I/O2  
I/O7  
Figure 46 shows the correlation between physical and logical CFI ports in CFI modes 0,  
1, 2 and 3:  
R
R
R
EPIC  
EPIC  
EPIC  
Logical Ports:  
Physical  
Pins:  
Logical Ports:  
Physical  
Pins:  
Logical Ports:  
Physical  
Pins:  
DD0  
DU0  
DD1  
DU1  
DD2  
DU2  
DD3  
DU3  
DD0  
DU2  
SIP0  
SIP1  
SIP2  
SIP3  
SIP4  
SIP5  
SIP6  
SIP7  
OUT0  
OUT0  
I/O0  
1
0
IN0  
I/O1  
I/O2  
I/O3  
I/O4  
I/O5  
I/O6  
I/O7  
IN0  
DU0  
R
OUT1  
IN1  
EPIC  
CMD1:  
CIS0  
Logical Ports:  
Physical  
Pins:  
OUT2  
IN2  
DD1  
DU3  
DD0  
DU2  
OUT1  
IN1  
OUT  
1
0
1
0
IN  
OUT3  
IN3  
DU1  
DU0  
CMD1:  
CIS1  
CMD1:  
CIS0  
CFI Mode 0  
CFI Mode 1  
CFI Mode 2  
CFI Mode 3  
ITS09549  
Figure 46  
Correlation Between Physical and Logical CFI Ports  
Semiconductor Group  
127  
 
 
PEB 2055  
PEF 2055  
Application Hints  
CFI subtime Slot Position CSCR  
If a time slot assignment is programmed in the control memory (CM), the used control  
memory code defines the channel bandwidth and the subchannel position at the PCM  
interface (refer to chapter 5.4.2). The subchannel position at the configurable interface  
however is defined on a per port basis in the Configurable interface SubChannel  
Register CSCR.  
The subchannel control bits SC#1 … SC#0 specify separately for each logical port the  
bit positions to be exchanged with the data memory (DM) when a connection with a  
channel bandwidth as defined by the CM code has been established:  
Table 20  
SC#1  
SC#0  
Bit Positions for CFI Subchannels Having a Bandwidth of  
64 kbit/s  
32 kbit/s  
16 kbit/s  
0
0
1
1
0
1
0
1
7 … 0  
7 … 0  
7 … 0  
7 … 0  
7 … 4  
3 … 0  
7 … 4  
3 … 0  
7 … 6  
5 … 4  
3 … 2  
1 … 0  
Table 21 shows the effect of the different subchannel control bits SC#1 … SC#0 on the  
CFI ports in each CFI mode:  
Table 21  
SC#1  
SC#0  
CFI Mode  
2
0
1
3
SC01  
SC11  
SC21  
SC31  
SC00  
SC10  
SC20  
SC30  
port 0  
port 1  
port 2  
port 3  
port 0  
port 1  
see note  
see note  
port  
ports 0 and 4  
ports 1 and 5  
ports 2 and 6  
ports 3 and 7  
see note  
see note  
see note  
Note: In CFI mode 1:SC21 = SC01; SC20 = SC00; SC31 = SC11; SC30 = SC10  
In CFI mode 2:SC31 = SC21 = SC11 = SC01; SC30 = SC20 = SC10 = SC00  
If for example at CFI port 1 a 16 kbit/s channel shall be switched to (or from) a CFI bit  
position 5 … 4 from (or to) any 2 bit subtime slot position at the PCM interface, a CM  
code defining a channel bandwidth of 16 kbit/s and defining the subchannel position at  
the PCM interface must be written to the CM code field of the involved 8 bit CFI time slot  
(i.e. 0111, 0110, 0101 or 0100). In order to insert (or extract) bit positions 5 … 4 of the  
selected 8 bit CFI time slot, SC11 … SC10 have to be set to 01. Once fixed to this value,  
all time slot connections programmed on CFI port 1 are performed on bits 7 … 0 for  
64 kbit/s channels, bits 3 … 0 for 32 kbit/s channels and bits 5 … 4 for 16 kbit/s  
channels.  
Semiconductor Group  
128  
 
PEB 2055  
PEF 2055  
Application Hints  
Since for each CFI time slot there is only one control memory location, only one  
subchannel may be mapped to each CFI time slot. The remaining bits of such a partly  
unused CFI time slot are inactive e.g. set to high impedance if OMDR:COS = 0.  
Note that if an odd numbered CFI time slot is initialized as an IOM channel with switched  
D channel, SC#1 … SC#0 must be set to “00” because the D channel is located at bits  
7 … 6. In this case the remaining bits can still be used for C/I and monitor channel  
applications (refer to chapter 5.5).  
For more detailed information on subchannel switching refer to chapter 5.4.2.  
CFI Standby Mode OMDR:CSB  
In standby mode (OMDR:CSB = 0), the CFI output ports are set to high impedance and  
the clock signals DCL and FSC, if programmed as outputs (CMD1:CSS = 0), are  
switched off.  
Note that the internal operation of the EPIC is not affected in standby mode, i.e. the  
received CFI data is still read in and may still be processed by the EPIC (switched to  
PCM or µP, etc.)  
In operational mode (OMDR:CSB = 1), the CFI output pins take over the function  
programmed in the control memory and DCL and FSC deliver clock and framing output  
signals (if CMD1:CSS = 0) as programmed in CMD1 and CMD2.  
CFI Output Driver Selection OMDR:COS  
The output drivers at the configurable interface (DD# or I/O#) can be programmed as  
open drain or tristate drivers.  
If programmed as open drain drivers (OMDR:COS = 1), external pull-up resistors  
(connected to VDD) are required in order to pull the output line to a high level if a logical  
1 is being transmitted. For unassigned channels (e.g. control memory code “0000”) the  
EPIC transmits a logical 1. The maximum output current at a low voltage level of 0.45 V  
is 7 mA, pull-up resistors down to 680 can thus be used.  
If programmed as tristate drivers (OMDR:COS = 0), logical 0s and 1s are transmitted  
with push-pull output drivers, whereas unassigned channels are set to high impedance.  
Semiconductor Group  
129  
PEB 2055  
PEF 2055  
Application Hints  
5.3  
Data and Control Memories  
Memory Structure  
5.3.1  
The EPIC memory is composed of the Control Memory (CM) and the Data Memory  
(DM). Their structure is shown in figure 47.  
The control memory refers to the Configurable Interface (CFI) such that for each CFI  
time slot and for each direction (upstream and downstream) there is a 4 bit code field  
and an 8 bit data field location.  
The code field defines the function of the corresponding CFI time slot. A time slot, may  
for example, be transparently switched through to the PCM interface (switched channel)  
or it may serve as monitor, feature control, command/indication or signaling channel in  
an IOM or SLD application (preprocessed channel) or it may be directly switched to the  
µP interface (µP channel).  
The use of the data field depends on the function defined by the code field. If a CFI time  
slot is defined as a switched channel, the data field is interpreted as a pointer to the data  
memory and defines therefore to which PCM time slot the connection shall be made. For  
preprocessed channels, the data field serves as a buffer for the command/indication or  
signaling value. If a µP channel is programmed, the data field content is directly  
exchanged with the CFI time slot.  
The data memory refers to the PCM interface such that for each upstream time slot  
there is a 4 bit code field and an 8 bit data field location, whereas for each downstream  
time slot there is only an 8 bit data field location.  
The data field locations buffer the PCM data transmitted and received over the PCM  
interface. The code field (tristate field) defines whether the upstream data field contents  
should be transmitted in the associated PCM time slot or whether the time slot should  
be switched to high impedance.  
Semiconductor Group  
130  
PEB 2055  
PEF 2055  
Application Hints  
Control Memory  
Data Field  
Data Memory  
Data Field  
CFI  
Frame  
PCM  
Frame  
Code Field  
Code Field  
0
0
Up-  
Up-  
stream  
stream  
127  
127  
0
0
Down-  
Down-  
stream  
stream  
127  
127  
ITD08062  
Figure 47  
EPIC® Memory Structure  
5.3.2  
Indirect Register Access  
The control and data memories must be accessed by the µP in order to initialize the CFI  
and PCM interfaces for the required functionality, to program time slot assignments, to  
access the control/signaling channels (IOM/SLD), etc.  
This access is performed through indirect addressing using the memory access  
registers MADR, MAAR, and MACR.  
Semiconductor Group  
131  
 
PEB 2055  
PEF 2055  
Application Hints  
Memory Access Data Register  
read/write  
reset value:  
undefined  
bit 7  
bit 0  
MADR  
MD7  
MD6  
MD5  
MD4  
MD3  
MD2  
MD1  
MD0  
The Memory Access Data Register MADR contains the data to be transferred from or to  
a memory location. The meaning and the structure of this data depends on the kind of  
memory being accessed. If, for example, MADR contains a pointer to a PCM time slot,  
the data must be encoded according to figure 48. If it contains a 4 bit C/I code the  
structure would for example be “11 C/I 11”. For accesses to 4 bit code fields only the 4  
least significant bits of MADR are relevant.  
Memory Access Address Register  
read/write  
reset value:  
undefined  
bit 0  
bit 7  
MAAR  
U/D  
MA6  
MA5  
MA4  
MA3  
MA2  
MA1  
MA0  
The Memory Access Address Register MAAR specifies the address of the memory  
access. This address encodes a CFI time slot for control memory and a PCM time slot  
for data memory accesses. Bit 7 of MAAR (U/D bit) selects between upstream and  
downstream memory blocks.  
Bits MA6 … 0 encode the CFI or PCM port and time slot number according to figure 48.  
Memory Access Control Register  
read/write  
reset value:  
undefined  
bit 0  
bit 7  
MACR  
RWS  
MOC3 MOC2 MOC1 MOC3/ CMC2 CMC1 CMC0  
CMC3  
The Memory Access Control Register MACR selects the type of memory (control or data  
memory), the type of field (data or code field) and the access mode (read or write) of the  
register access. When writing to the control memory code field, MACR also contains the  
4 bit code (CMC3 … 0) defining the function of the addressed CFI time slot.  
Semiconductor Group  
132  
PEB 2055  
PEF 2055  
Application Hints  
Port# (0-3)  
CFI Mode 0  
PCM Mode 0  
4 Duplex Ports  
32 Tume-Slots/Port  
U/D  
U/D  
U/D  
U/D  
U/D  
Time-Slot# (0-31)  
Time-Slot# (0-63)  
Port# (0-1)  
CFI Mode 1  
2 Duplex Ports  
64 Time-Slots/Port  
Port# (0-1)  
PCM Mode 1  
2 Duplex Ports  
64 Time-Slots/Port  
Time-Slot# (0-63)  
CFI Mode 2  
PCM Mode 2  
1 Duplex Port  
128 Time-Slots/Port  
Time-Slot# (0-127)  
Port# (0-3)  
CFI Mode 3  
8 Bidirectional Ports  
16 Time-Slots/Port  
Time-Slot# (0-15)  
U/D : (1) / Downstream (0)  
ITD08063  
Figure 48  
Time Slot Encoding for the Different PCM and CFI Modes  
Memory Access Time  
Writing to MACR starts a memory write or read operation which takes a certain time.  
During this time no further memory accesses may be performed i.e. the MADR, MAAR,  
and MACR registers may not be written. The STAR:MAC bit indicates whether a memory  
operation is still in progress (MAC = 1) or already completed (MAC = 0) and should  
therefore be interrogated before each access.  
Semiconductor Group  
133  
 
PEB 2055  
PEF 2055  
Application Hints  
Since memory operations must be synchronized to the EPIC internal bus which is  
clocked by the reference clock (RCL), the time required for an indirect register access  
can be given as a multiple of RCL clock cycles. A “normal” access to a single memory  
location, for example, takes a maximum of 9.5 RCL cycles which is approximately 2.4 µs  
assuming a 4 MHz clock (e.g. CFI configured as standard IOM-2 interface).  
Memory Access Modes  
Access to memory locations is furthermore influenced by the operation mode set via the  
Operation Mode Register OMDR. There are 4 modes which can be selected with the  
OMDR:OMS1, OMS0 bits:  
Operation Mode Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
RBS  
OMDR  
OMS1 OMS0  
PSB  
PTL  
COS  
MFPS  
CSB  
– The CM reset mode (OMS1 … 0 = 00) is used to reset all locations of the control  
memory code and data fields with a single command within only 256 RCL cycles. A  
typical application is resetting the CM with the command MACR = 70H which writes  
the contents of MADR (XXH) to all data field locations and the code “0000”  
(unassigned channel) to all code field locations. A CM reset should be made after  
each hardware reset. In the CM reset mode the EPIC does not operate normally i.e.  
the CFI and PCM interfaces are not operational.  
– The CM initialization mode (OMS1 … 0 = 10) allows fast programming of the  
Control Memory since each memory access takes a maximum of only 2.5 RCL cycles  
compared to the 9.5 RCL cycles in the normal mode. Accesses are performed on  
individual addresses specified by MAAR. The initialization of control/signaling  
channels in IOM or SLD applications can, for example, be carried out in this mode  
(see chapter 5.5.1). In the CM initialization mode the EPIC does also not work  
normally.  
– In the normal operation mode (OMS1 … 0 = 11) the CFI and PCM interfaces are  
operational. Memory accesses performed on single addresses (specified by MAAR)  
take 9.5 RCL cycles. An initialization of the complete data memory tristate field takes  
1035 RCL cycles.  
– In test mode (OMS1 … 0 = 01) the EPIC sustains normal operation. However  
memory accesses are no longer performed on a specific address defined by MAAR,  
but on all locations of the selected memory, the contents of MAAR (including the U/D  
bit!) being ignored. This function can for example be used to program a PCM idle code  
to all PCM ports and time slots with a single command.  
Semiconductor Group  
134  
PEB 2055  
PEF 2055  
Application Hints  
5.3.3  
Memory Access Commands  
The memory access commands can be divided into the following four categories:  
– Access to the Data Memory Data Field: µP access to PCM frame  
– Access to the Data Memory Code Field: PCM tristate control  
– Access to the Control Memory Data Field: time slot assignment, µP access to CFI  
frame  
– Access to the Control Memory Code Field: set-up of CFI time slot functionality  
In the following chapters, these commands are explained in more detail.  
5.3.3.1 Access to the Data Memory Data Field  
The data memory (DM) data field buffers the PCM data transmitted (upstream block) and  
received (downstream block) via the PCM interface. Normally this data is switched  
transparently from or to the CFI and there is no need to access it from the µP interface.  
For some applications however it is useful to have a direct µP access to the PCM frame.  
When an upstream PCM time slot (or even subtime slot) is not switched from the CFI  
(unassigned channel), it is possible to write a fixed value to the corresponding DM data  
field location. This value will then be transmitted repeatedly in each PCM frame without  
further µP interaction (PCM idle code). If instead a continuous pattern should be sent,  
the write access can additionally be synchronized to the frame by means of synchronous  
transfer interrupts (see chapter 5.7).  
Writing to an upstream DM data field location can also be restricted to a 2 or 4 bit subtime  
slot. It is thus possible to have certain subtime slots of the same 8 bit time slot switched  
from the CFI with the other subtime slots containing a PCM idle code. This restriction is  
made via the Memory Operation Code (refer to table 22).  
For test purposes the upstream DM data field contents can also be read back.  
The downstream DM data field cannot be written to, it can only be read. Reading such  
a location reflects the PCM data contained in the received PCM frame regardless of a  
connection to the CFI having been established or not. The µP can thus determine the  
contents of received PCM time slots simply by reading the corresponding downstream  
DM locations. This reading can, if required, also be synchronized to the frame by means  
of synchronous transfer interrupts.  
Semiconductor Group  
135  
PEB 2055  
PEF 2055  
Application Hints  
The Procedure for Writing to the Upstream DM Data Field is  
W:MADR = value to be transmitted in the PCM (sub)time slot  
W:MAAR = address of the desired (upstream)1) PCM time slot encoded according to  
figure 48  
bit 7  
bit 0  
W:MACR =  
0
MOC3 MOC2 MOC1 MOC0  
0
0
0
MOC3 0 defines the bandwidth and the position of the subchannel according to  
table 22.  
Table 22  
MOC3 … 0  
Transferred Bits  
Channel Bandwidth  
0000  
0001  
0011  
0010  
0111  
0110  
0101  
0100  
bits 7 … 0  
bits 7 … 4  
bits 3 … 0  
bits 7 … 6  
bits 5 … 4  
bits 3 … 2  
bits 1 … 0  
64 kbit/s  
32 kbit/s  
32 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
The Procedure for Reading the DM Data Field is  
W:MAAR = address of the desired PCM time slot encoded according to figure 48  
2)  
W:MACR = 1000 0000B = 80H  
wait for STAR:MAC = 0  
R:MADR = value  
Figure 49 illustrates the access to the Data Memory Data Field.  
1)  
The U/D bit of MAAR will implicitly be set to 1.  
When reading a DM data field location, all 8 bits are read regardless of the bandwidth selected by the MOC  
2)  
bits.  
Semiconductor Group  
136  
 
PEB 2055  
PEF 2055  
Application Hints  
Data Memory  
Data Field  
PCM  
Frame  
0
U/D = 1  
Up-  
stream  
127  
0
U/D = 0  
Down-  
stream  
127  
MAAR: U/D MA6  
.
.
.
.
.
MA0  
MADR: MD7  
.
.
.
.
.
.
MD0  
MACR: RWS MOC3 ... 0  
0
0
0
ITD08064  
Figure 49  
Access to the Data Memory Data Field  
Semiconductor Group  
137  
PEB 2055  
PEF 2055  
Application Hints  
Examples  
In PCM mode 0 the idle code “1010 0101B” shall be transmitted in time slot 16 of port 0:  
W:MADR = 1010 0101B ; idle code  
W:MAAR = 1100 0000B ; address of upstream PCM time slot 16 of port 0  
according to figure 48  
W:MACR = 0000 1000B : write access, MOC code “0001”  
The idle code can, of course, only be transmitted on the TxD# line if the corresponding  
tristate bits are enabled (refer to chapter 5.3.3.2):  
W:MADR = XXXX 1111B ; all 8 bits of addressed time slot to low impedance  
W:MAAR = 1100 0000B ; address of upstream PCM time slot 16 of port 0  
according to figure 48  
W:MACR = 0110 0000B : write access, MOC code “1100”  
For test purposes the idle code can also be read back:  
W:MAAR = 1100 0000B ; address of upstream PCM time slot 16 of port 0  
according to figure 48  
W:MACR = 10XX X000B : read access, MOC code “0XXX”  
wait for STAR:MAC = 0  
R:MADR = 1010 0101B ; idle code  
In PCM mode 2 the idle pattern “0110” shall be transmitted in bit positions 3 … 0 of time  
slot 63, bits 7 … 4 shall be tristated:  
W:MADR = XXXX 0110B ; idle code  
W:MAAR = 1011 1111B ; address of upstream PCM time slot 63  
according to figure 48  
W:MACR = 0001 0000B ; write access, MOC code “0010”  
Programming of the desired tristate functions:  
W:MADR = XXXX 0011B ; bits 7 … 4 to high impedance, bits 3 … 0 to low  
impedance  
W:MAAR = 1011 1111B ; address of upstream PCM time slot 63  
according to figure 48  
W:MACR = 0110 0000B ; write access, MOC code “1100”  
Semiconductor Group  
138  
PEB 2055  
PEF 2055  
Application Hints  
5.3.3.2 Access to the Data Memory Code (Tristate) Field  
The data memory code field exists only for the upstream DM block and is also called the  
PCM tristate field. Each (sub)time slot of each PCM transmit port can be individually  
tristated via these code field locations.  
If a (sub)time slot is set to low impedance, the contents of the corresponding DM data  
field location is transmitted with a push-pull driver onto the transmit port TxD# and the  
tristate control line TSC# is pulled low for the duration of that (sub)time slot.  
If a (sub)time slot is set to high impedance, the transmit port TxD# will be tristated and  
the TSC# line is pulled high for the duration of that (sub)time slot.  
There are 4 code bits for selecting the tristate function of each 8 bit time slot i.e. 1 control  
bit for each 16 kbit/s (2 bits) subtime slot. If a control bit is set to 1, the corresponding  
subtime slot is set to low impedance, if it is set to 0 the subtime slot is tristated.  
Figure 50 illustrates this behavior.  
PCM Time-Slot#  
DM Data Field  
N
N+1  
N+2  
N+3  
X X X X 0  
1
1
0 X X  
1
1 X X 0 1 X X X X X X X X 1 0 1 1 0 0 1 0  
DM Tristate Field  
0
0
1
1
0
1
0
1
0
0
0
0
1
1
1
1
1 -  
0 -  
TxD#  
TSC#  
High Z  
1 -  
0 -  
ITD08065  
Figure 50  
Tristate Control at the PCM Interface  
The tristate field can be written to and, for test purposes, also be read back.  
There are two commands (Memory Operation Codes) for accessing the tristate field:  
With the “Single Channel Tristate Control” command (MOC3 … 0 = 1100) the tristate  
field of a single PCM time slot can be written to and also read back. The 4 least  
significant bits of MADR are exchanged with the code field of the time slot selected by  
the MAAR register.  
With the “Tristate Control Reset” command (MOC3 … 0 = 1101) the tristate field of all  
PCM time slots can be written to with a single command. The 4 bits of MADR are then  
copied to all code field locations regardless of the address programmed to MAAR. Such  
a complete access to the DM tristate field takes 1035 RCL cycles.  
Semiconductor Group  
139  
 
PEB 2055  
PEF 2055  
Application Hints  
The MADR bits MD7 … MD0 control the PCM time slot bit positions 7 … 0 in the  
following way:  
MD7 … MD4 are not used (don’t care);  
MD3 … MD0 select between the states high impedance (MD# = 0) or low impedance  
(MD# = 1)  
time slot Bit Position:  
MADR Bits:  
7
6
5
4
3
2
1
0
MD3  
MD2  
MD1  
MD0  
The Procedure for Writing to a Single PCM Tristate Field is  
W:MADR = X X X X MD3 MD2 MD1 MD0B  
W:MAAR = address of the desired (upstream)1) PCM time slot according to figure  
48  
W:MACR = 0110 000B = 60H  
The Procedure for Reading Back a (Single) PCM Tristate Field Location is  
W:MAAR = address of the desired (upstream)1) PCM time slot according to figure 48  
W:MACR = E0H  
wait for STAR:MAC = 0  
R:MADR = X X X X MD3 MD2 MD1 MD0B  
The Procedure for Writing to all PCM Tristate Field Positions is  
W:MADR = X X X X MD3 MD2 MD1 MD0B  
W:MACR = 0110 1000B = 68H  
1)  
The U/D bit of MAAR will implicitly be set to 1.  
Semiconductor Group  
140  
PEB 2055  
PEF 2055  
Application Hints  
Figure 51 illustrates the access to the tristate field:  
Data Memory  
PCM  
Code Field  
Frame  
0
U/D = 1  
Up-  
stream  
127  
MAAR: U/D MA6  
.
.
.
.
.
MA0  
MADR:  
X
X
X
X
MD3 MD2 MD1 MD0  
MACR: RWS  
1
1
0
0/1  
0
0
0
ITD08066  
Figure 51  
Access to the Data Memory Code (Tristate) Field  
Examples  
All PCM time slots shall be set to high impedance (disabled):  
W:MADR = 00H  
W:MACR = 68H  
; all bits to high impedance  
; write access with MOC = 1101  
All PCM time slots shall be set to low impedance (enabled):  
W:MADR = FFH  
W:MACR = 68H  
; all bits to low impedance  
; write access with MOC = 1101  
In PCM mode 1, bits 7 … 6 and 1 … 0 of PCM port 1, time slot 10 shall be set to low  
impedance, bits 5 … 2 to high impedance:  
W:MADR = 0000 1001B ; bits 7 … 6 and 1 … 0 to low impedance, bits 5 … 2  
to high impedance  
W:MAAR = 1010 1010B ; address of upstream PCM port 1, time slot 10  
according to figure 48  
W:MACR = 0110 0000B ; write access with MOC = 1100  
Semiconductor Group  
141  
 
PEB 2055  
PEF 2055  
Application Hints  
For test purposes this setting shall be read back:  
W:MAAR = 1010 1010B ; address of upstream PCM port 1, time slot 10  
according to figure 48  
W:MACR = 1110 0000B = E0H; read access with MOC = 1100  
wait for STAR:MAC = 0  
R:MADR = XXXX 1001B ; read back of MD3 … 0  
5.3.3.3 Access to the Control Memory Data Field  
Writing to or reading the control memory (CM) data field may serve different purposes  
depending on the function given to the corresponding CFI time slot which is defined by  
the 4 bit code field value:  
Table 23  
CFI Time Slot Application  
Meaning of CM Data Field  
Switched channel  
Preprocessed channel  
µP channel  
Pointer to PCM interface  
C/I or SIG value  
CFI idle code  
There are two types of commands which give access to the CM data field:  
The memory operation code MACR:MOC = 111X is used for writing to the CM data field  
and code field simultaneously. The MADR content is transferred to the data field while  
the MACR:CMC3 … 0 bits are transferred to the code field. This command is explained  
in more detail in chapter 5.3.3.4.  
The memory operation code MACR:MOC = 1001 is used for reading or writing to the CM  
data field. Since the CM code field is not affected, this command makes only sense if the  
related CFI time slot has already the desired functionality.  
The Procedure for Writing to the CM Data Field (using the MOC = 1001 command)  
is  
W:MADR = value  
W:MADR = CFI time slot address according figure 48  
R:MADR = 0100 1000B = 48H  
The Procedure for Reading the CM Data Field is  
W:MAAR = CFI time slot address according figure 48  
W:MACR = 1100 1000B = C8H  
wait for STAR:MAC = 0  
R:MADR = value  
Semiconductor Group  
142  
 
PEB 2055  
PEF 2055  
Application Hints  
Figure 52 illustrates this behavior.  
Control Memory  
Data Field  
CFI  
Frame  
0
Up-  
U/D = 1  
stream  
127  
0
Down-  
stream  
U/D = 0  
127  
MAAR: U/D MA6  
.
.
.
.
.
MA0  
MADR: MD7  
.
.
.
.
.
.
MD0  
MACR: RWS  
1
0
0
1
0
0
0
ITD08067  
Figure 52  
Access to the Control Memory Data Field  
Semiconductor Group  
143  
 
PEB 2055  
PEF 2055  
Application Hints  
Examples  
In CFI mode 2, CFI time slot 123 has been initialized as a switched channel. The CM  
data field value therefore represents a pointer to the PCM interface.  
In a first step, the involved upstream and downstream PCM time slots shall be  
determined:  
W:MAAR = 1111 1011B ; address of upstream CFI time slot 123  
W:MACR = 1100 1000B ; read back command  
wait for STAR:MAC = 0  
R:MADR = value  
; encoded according figure 48  
W:MAAR = 0111 1011B ; address of downstream CFI time slot 123  
W:MACR = 1100 1000B ; read back command  
wait for STAR:MAC = 0  
R:MADR = value  
; encoded according figure 48  
In the next step a new time slot assignment (to PCM port 1, time slot 34, PCM mode 1)  
shall be made for the upstream connection:  
W:MADR = 1100 0110B ; upstream PCM time slot 34, port 1  
W:MAAR = 1111 1011B ; address of upstream CFI time slot 123  
W:MACR = 0100 1000B ; write command  
5.3.3.4 Access to the Control Memory Code Field  
The 4 bit code field of the control memory (CM) defines the functionality of a CFI time  
slot and thus the meaning of the corresponding data field.  
There are codes for switching applications, preprocessed applications and for direct µP  
access applications (see table 24).  
This 4 bit code, written to the MACR:CMC3 … 0 bit positions, will be transferred to the  
CM code field by selecting MACR:MOC = 111X. The 8 bit MADR value is at the same  
time transferred to the CM data field.  
The Procedure for Writing to the CM Code and Data Fields with a Single  
Command is  
W:MADR = value for data field  
W:MAAR = CFI time slot address encoded according to figure 48  
bit 7  
bit 0  
W:MACR =  
0
1
1
1
CMC3 CMC2 CMC1 CMC0  
CMC3 … 0 CM code, refer to table 24  
Semiconductor Group  
144  
PEB 2055  
PEF 2055  
Application Hints  
Figure 53 illustrates this behavior.  
Control Memory  
CFI  
Frame  
Code Field  
Data Field  
0
Up-  
U/D = 1  
stream  
127  
0
Down-  
stream  
U/D = 0  
127  
MACR:  
0
1
1
1
CMC 3 ... 0  
MADR: MD7  
.
.
.
.
.
.
MD0  
MAAR: U/D MA6  
.
.
.
.
.
MA0  
ITD08068  
Figure 53  
Write Access to the Control Memory Data and Code Fields  
For reading back the CM code field, the command MACR:MOC = 111X is also used, the  
value of CMC3 … 0 being don’t care. The code field value can then be read from the  
lower 4 bits of MADR.  
Semiconductor Group  
145  
 
PEB 2055  
PEF 2055  
Application Hints  
The Procedure for Reading the CM Code is  
W:MAAR = CFI time slot address encoded according to figure 48  
W:MACR = 1111 XXXXB  
wait for STAR:MAC = 0  
bit 7  
bit 0  
CMC3 CMC2 CMC1 CMC0  
R:MADR =  
X
X
X
X
CMC3 … 0: CM code, refer to table 24  
Figure 54 illustrates this behavior.  
Control Memory  
Code Field  
CFI  
Frame  
0
Up-  
U/D = 1  
stream  
127  
0
Down-  
stream  
U/D = 0  
127  
MACR:  
1
1
1
1
X
X
X
X
MADR:  
X
X
X
X
MD3 MD2 MD1 MD0  
MAAR: U/D MA6  
.
.
.
.
.
MA0  
ITD08069  
Figure 54  
Read Access to the Control Memory Code Field  
Semiconductor Group  
146  
 
PEB 2055  
PEF 2055  
Application Hints  
Table 24 shows all available Control Memory codes.  
Table 24  
Application  
CMC3 … 0  
Transferred Bits  
Channel Bandwidth  
Disable connection  
0000  
unassigned  
64 kbit/s  
32 kbit/s  
32 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
Switched 8 bit channel 0001  
Switched 4 bit channel 0011  
Switched 4 bit channel 0010  
Switched 2 bit channel 0111  
Switched 2 bit channel 0110  
Switched 2 bit channel 0101  
Switched 2 bit channel 0100  
bits 7 … 0  
bits 7 … 4  
bits 3 … 0  
bits 7 … 6  
bits 5 … 4  
bits 3 … 2  
bits 1 … 0  
Preprocessed channel 1000  
Preprocessed channel 1010  
Preprocessed channel 1011  
refer to chapter 5.5  
µP channel  
1001  
refer to chapter 5.6  
and chapter 5.7  
Examples  
In CFI mode 2, CFI time slot 123 shall be initialized as a switched channel. The CM data  
field value therefore represents a pointer to the PCM interface.  
In a first step, a time slot assignment to PCM port 1, time slot 34 (PCM mode 1) shall be  
made for a 64 kbit/s upstream connection:  
W:MADR = 1100 0110B ; upstream PCM time slot 34, port 1  
W:MAAR = 1111 1011B ; address of upstream CFI time slot 123  
W:MACR = 0111 0001B ; write data + code field command, code “0001”  
In a next step, the bandwidth of the previously made connection shall be verified:  
W:MAAR = 1111 1011B ; address of upstream CFI time slot 123  
W:MACR = 1111 0000B ; read back code field command  
wait for STAR:MAC = 0  
R:MADR = XXXX 0001B ; the code “0001” (64 kbit/s channel) is read back  
Semiconductor Group  
147  
 
PEB 2055  
PEF 2055  
Application Hints  
Tristate Behavior at the Configurable Interface  
The downstream control memory code field, together with the CSCR and OMDR  
registers also defines the state of the output driver at the downstream CFI ports.  
Unassigned channels (code “0000”) are set to the inactive state. Subchannels (codes  
“0010” to “0111”) are only active during the subtime slot position specified in CSCR. The  
OMDR:COS bit selects between tristate outputs and open drain outputs:  
Table 25  
Logical State  
Tristate Outputs  
Open Drain Outputs  
Logical 0  
Logical 1  
Inactive  
Low voltage level  
High voltage level  
High impedance  
Low voltage level  
Not driven1)  
Not driven1)  
1)  
An external pull-up resistor is required to establish a high voltage level.  
Figure 55 illustrates this behavior in case of tristate outputs:  
CFI Time-Slot #  
CM Data Field  
N
N+1  
N+2  
N+3  
X X X X X X X X  
Pointer to DM  
Pointer to DM  
1 0 1 1 0 0 1 0  
CM Code Field  
0
0
0
0
0
0
0
1
0
1
1
0
1
0
0
1
1 -  
0 -  
DD #  
High Z  
Unassigned  
Channel  
64 kbit/s Channel  
(Switched from PCM)  
16 kbit/s Channel  
CSCR : SC#1..#0 = 01  
(Switched from PCM)  
µP Channel  
(Always 64 kbit/s)  
ITD08070  
Figure 55  
Tristate Behavior at the CFI  
Semiconductor Group  
148  
 
PEB 2055  
PEF 2055  
Application Hints  
Table 26  
Summary of Memory Operations  
Application  
MADR  
MAAR  
MACR (Hex)  
Writing a PCM idle value to 8 bit, 4 bit or 2 bit idle Address of the  
08H (bits 7 … 0)  
the upstream DM data field value to be transmitted (upstream)PCM 18H (bits 7 … 4)  
The MACR value specifies at the PCM interface  
the bandwidth and bit  
position at the PCM  
port and time  
slot  
10H (bits 3 … 0)  
38H (bits 7 … 6)  
30H (bits 5 … 4)  
28H (bits 3 … 2)  
20H (bits 1 … 0)  
interface  
Reading the up- or  
downstream DM data field at the upstream or 8 bit PCM port and  
8 bit value transmitted Address of the  
88H  
60H  
68H  
value received at the time slot  
downstream PCM  
interface  
Writing to a single tristate Tristate information  
field location  
Address of the  
(upstream)PCM  
port and time  
slot  
contained in the  
4 LSBs:  
0 = tristated,  
1 = active  
Writing to all tristate field  
locations  
Tristate information  
contained in the  
4 LSBs:  
Don’t care  
0 = tristated,  
1 = active  
Reading a single tristate  
field location  
Tristate information  
contained in the 4  
LSBs  
Address of the  
(upstream)PCM  
port and time  
slot  
E0H  
48H  
Writing to the CM data field 8 bit value  
(C/I value, pointer to  
Address of the  
CFI port and  
time slot  
PCM interface, etc.)  
Semiconductor Group  
149  
PEB 2055  
PEF 2055  
Application Hints  
Table 26  
Summary of Memory Operations  
Application  
MADR  
MAAR  
MACR (Hex)  
Reading the CM data field 8 bit value  
Address of the  
C8H  
(C/I value, pointer to CFI port and  
PCM interface, etc.) time slot  
Reading the CM code field 4 bit code contained in Address of the  
F0H  
the 4 LSBs  
CFI port and  
time slot  
Writing a switching code to Pointer to DM:  
Address of the  
CFI port and  
time slot  
70H  
(unassigned)  
the CM  
PCM port and  
time slot  
71H (bits 7 … 0)  
73H (bits 7 … 4)  
72H (bits 3 … 0)  
77H (bits 7 … 6)  
76H (bits 5 … 4)  
75H (bits 3 … 2)  
74H (bits 1 … 0)  
The MACR value specifies  
the bandwidth and bit  
position at the PCM  
interface  
Writing the “µP channel”  
code to the CM  
8 bit idle value  
Address of the  
CFI port and  
time slot  
79H  
Writing a “preprocessed  
channel” code to the CM  
refer to figure 68  
refer to  
figure 68  
refer to  
figure 68  
Semiconductor Group  
150  
PEB 2055  
PEF 2055  
Application Hints  
5.4  
Switched Channels  
This chapter treats the switching functions between the CFI and PCM interfaces which  
are programmed exclusively in the control memory. The switching functions of channels  
which involve the µP interface or which are programmed in the synchronous transfer  
registers are treated in chapter 5.6 and chapter 5.7.  
The EPIC is a non-blocking space and time switch for 128 channels per direction.  
Switching is performed between the configurable (CFI) and the PCM interfaces. Both  
interfaces provide up to 128 time slots which can be split up into either 4 ports with up to  
32 time slots, 2 ports with up to 64 time slots or 1 port with up to 128 time slots. In all of  
these cases each port consists of a separate transmit and receive line (duplex ports). On  
the CFI side a bidirectional mode is also provided (CFI mode 3) which offers 8 ports with  
up to 16 time slots per port. In this case each time slot of each port can individually be  
programmed to be either input or output.  
The time slot numbering always ranges from 0 to N – 1 (N = number of time slots/frame),  
and each time slot always consists of 8 contiguous bits. The bandwidth of a time slot is  
therefore always 64 kbit/s.  
The EPIC can switch single time slots (64 kbit/s channels), double time slots (128 kbit/s  
channels) and also 2 bit and 4 bit wide subtime slots (16 and 32 kbit/s channels). The  
bits in a time slot are numbered 7 through 0. On the serial interfaces (PCM and CFI),  
bit 7 is the first bit to be transmitted or received, bit 0 the last. If the µP has access to the  
serial data, bit 7 represents the MSB (D7) and bit 0 the LSB (D0) on the µP bus.  
The switching of 128 kbit/s channels implies that two consecutive time slots starting with  
an even time slot number are used, e.g. PCM time slots 22 and 23 can be switched as  
a single 16 bit wide time slot to CFI time slots 4 and 5. Under these conditions it is  
guaranteed that the involved time slots are submitted to the same frame delay (also refer  
to chapter 5.4.4).  
The switching of channels with a data rate of 16 and 32 kbit/s is possible for the following  
subtime slot positions within an 8 bit time slot:  
Semiconductor Group  
151  
PEB 2055  
PEF 2055  
Application Hints  
8 bit time slot:  
7
7
6
6
5
5
4
4
3
3
2
2
1
0
0
32 kbit/s channel  
32 kbit/s channel  
16 kbit/s channel  
16 kbit/s channel  
16 kbit/s channel  
16 kbit/s channel  
1
7
6
5
4
3
2
1
0
5.4.1  
CFI - PCM Time Slot Assignment  
All time slot assignments are programmed in the control memory (CM). Each line  
(address) of the CM refers to one CFI time slot. The MAAR register, which is used to  
address the CM, therefore specifies the CFI port and time slot to be switched. The data  
field of the CM contains a pointer which points to a location in the data memory (DM).  
The data memory contains the actual PCM data to be switched. The MADR register  
contains the data to be copied to the CM data field. Since this data is interpreted as a  
pointer to the DM, the MADR contents therefore specifies the PCM port and time slot to  
be switched. The 4 bit CM code field must finally contain a value to declare the  
corresponding CFI time slot as a switched channel (codes with a leading 0). This code  
must be written at least once to the CM using the MACR register.  
Since the CFI - PCM time slot assignment is programmed at the CFI side, it is possible  
to switch a single downstream PCM time slot to several downstream CFI time slots. It is,  
however, not possible to switch a single upstream CFI time slot to several upstream  
PCM time slots.  
If several upstream 64 kbit/s CFI time slots are assigned to the same upstream 64 kbit/s  
PCM time slot, only the data of one CFI time slot will actually be switched since each  
upstream connection will simply overwrite the DM data field. This switching mode can  
therefore only effectively be used if the upstream switching is performed on different  
subtime slot locations within the same PCM time slot (refer to chapter 5.4.2).  
The following sequences can be used to program, verify, and cancel a CFI - PCM time  
slot connection:  
Semiconductor Group  
152  
PEB 2055  
PEF 2055  
Application Hints  
Programming of a 64 kbit/s CFI - PCM Time Slot Connection  
– in case the CM code field has not yet been initialized with a switching code:  
W:MADR = PCM port and time slot encoded according to figure 48  
W:MAAR = CFI port and time slot encoded according to figure 48  
W:MACR = 0111 0001B = 71H  
– in case the CM code field has already been initialized with a switching code:  
W:MADR = PCM port and time slot encoded according to figure 48  
W:MAAR = CFI port and time slot encoded according to figure 48  
W:MACR = 0100 1000B = 48H  
Enabling the PCM Output Driver for a 64 kbit/s Time Slot  
W:MADR = XXXX 1111B = XFH  
W:MAAR = PCM port and time slot encoded according to figure 48  
W:MACR = 0110 0000B = 60H  
Reading Back a Time Slot Assignment of a Given CFI Time Slot  
– reading back the PCM time slot involved:  
W:MAAR = CFI port and time slot encoded according to figure 48  
W:MACR = 1100 1000B = C8H  
wait for STAR:MAC = 0  
R:MADR = PCM port and time slot encoded according to figure 48  
– reading back the involved bandwidth and PCM subtime slot position:  
W:MAAR = CFI port and time slot encoded according to figure 48  
W:MACR = 1111 0000B = F0H  
wait for STAR:MAC = 0  
R:MADR = XXXX code; 4 bit bandwidth code encoded according to table 24  
Cancelling of a Programmed CFI - PCM Time Slot Connection  
W:MADR = don’t care  
W:MAAR = CFI port and time slot encoded according to figure 48  
W:MACR = 0111 0000B = 70H; code “0000” (unassigned channel)  
Disabling the PCM Output Driver  
W:MADR = XXXX 0000B = X0H  
W:MAAR = PCM port and time slot encoded according to figure 48  
W:MACR = 0110 0000B = 60H  
Semiconductor Group  
153  
PEB 2055  
PEF 2055  
Application Hints  
Examples  
In PCM mode 1 and CFI mode 3 the following connections shall be programmed:  
Upstream: CFI port 5, time slot 7, bits 7 … 0 to PCM port 0, time slot 12, bits 7 … 0  
W:MADR = 1001 1000B ; PCM time slot encoding according to figure 48  
W:MAAR = 1011 1011B ; CFI time slot encoding according to figure 48  
W:MACR = 0111 0001B ; CM code for switching a 64 kbit/s channel  
(code “0001”)  
Downstream: CFI port 4, time slot 2, bits 7 … 0 from PCM port 1, time slot 3, bits 7 … 0  
W:MADR = 0000 0111B ; PCM time slot encoding according to figure 48  
W:MAAR = 0001 1000B ; CFI time slot encoding according to figure 48  
W:MACR = 0111 0001B ; CM code for switching a 64 kbit/s channel (0001)  
The following sequence sets transmit time slot 12 of PCM port 0 to low impedance:  
W:MADR = 0000 1111B ; all bits to low Z  
W:MAAR = 1001 1011B ; PCM time slot encoding according to figure 48  
W:MACR = 0110 0000B ; MOC code “1100” to access the tristate field  
Semiconductor Group  
154  
PEB 2055  
PEF 2055  
Application Hints  
After these three programming steps, the EPIC memories will have the following  
contents:  
Control Memory  
Data Field  
Data Memory  
Data Field  
CFI  
Frame  
PCM  
Frame  
Code Field  
Code Field  
0
0
Up-  
Up-  
stream  
P5, TS7  
0
0
0
1
1 0 0 1 1 0 0 0  
stream  
1
1
1
1
P0, TS12  
127  
127  
0
0
P1, TS3  
P4, TS2  
0
0
0
1
0 0 0 0 0 1 1 1  
Down-  
Down-  
stream  
stream  
127  
127  
ITD08071  
Figure 56  
Memory Content of the EPIC® for a CFI - PCM Time Slot Connection  
Semiconductor Group  
155  
PEB 2055  
PEF 2055  
Application Hints  
5.4.2  
Subchannel Switching  
The switching of subchannels is programmed by first specifying the time slot (which is  
always 8 bits wide) to be switched, then by restricting the actual switching operation to  
the desired bandwidth and subtime slot position. The switching function for an (8 bit) CFI  
time slot is programmed in the control memory (CM) by writing a pointer that points to  
an (8 bit) PCM time slot to the corresponding data field location. The MADR register  
contains the pointer (PCM time slot) and the MAAR register is used to specify the CFI  
time slot.  
The “8 bit” connection can now be restricted to the desired 4 or 2 bit connection by  
selecting an appropriate control memory code. The code is programmed via  
MACR:CMC3 … 0. These subchannel codes perform two functions: they specify the  
bandwidth (actual number of bits to be switched) and the location of the subtime slot  
within the selected (8 bit) PCM time slot. The location of the subtime slot within the  
selected (8 bit) CFI time slot is predefined by the setting of the CSCR register. Each CFI  
port can be set to a different subtime slot mode. In each mode a certain relationship  
exists between programmed bandwidth (which can still be individually selected for each  
CFI time slot) and the occupied bit positions within the time slot (which is fixed for each  
CFI port by the CSCR register).  
It should be noted that only one subtime slot can exist within a given CFI time slot. On  
the PCM side however each time slot may be split up into 2 × 4 bits, 4 × 2 bits or any  
mixture of these.  
The CSCR register has the following format:  
CFI Subchannel Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
CSCR  
SC31  
SC30  
SC21  
SC20  
SC11  
SC10  
SC01  
SC00  
Below, all possible combinations of subchannel switching between the CFI and PCM  
interfaces are shown:  
Semiconductor Group  
156  
 
PEB 2055  
PEF 2055  
Application Hints  
Subchannel selection SC#1 … SC#0 = 00:  
CM code  
CFI subchannel position  
switched  
to or from  
PCM subchannel position  
CFI time slot →  
PCM time slot →  
0001  
0011  
0010  
0111  
0110  
0101  
0100  
7
7
7
7
7
7
7
6
6
6
6
6
6
6
5
5
5
4
4
4
3
2
1
0
←→  
←→  
←→  
←→  
←→  
←→  
←→  
7
7
6
6
5
5
4
4
3
2
1
0
0
3
2
1
7
6
5
4
3
2
1
0
Subchannel selection SC#1 … SC#0 = 01:  
CM code  
CFI subchannel position  
switched  
to or from  
PCM subchannel position  
CFI time slot →  
PCM time slot →  
0001  
0011  
0010  
0111  
0110  
0101  
0100  
7
6
5
4
3
3
3
2
2
2
1
1
1
0
0
0
←→  
←→  
←→  
←→  
←→  
←→  
←→  
7
7
6
6
5
5
4
4
3
2
1
0
0
3
2
1
5
5
5
5
4
4
4
4
7
6
5
4
3
2
1
0
Semiconductor Group  
157  
PEB 2055  
PEF 2055  
Application Hints  
Subchannel selection SC#1 … SC#0 = 10:  
CM code  
CFI subchannel position  
switched  
to or from  
PCM subchannel position  
CFI time slot →  
PCM time slot →  
0001  
0011  
0010  
0111  
0110  
0101  
0100  
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
3
3
2
1
0
←→  
←→  
←→  
←→  
←→  
←→  
←→  
7
7
6
6
5
5
4
4
3
2
1
0
0
3
2
1
2
2
2
2
7
6
5
4
3
2
1
0
Subchannel selection SC#1 … SC#0 = 11:  
CM code  
CFI subchannel position  
switched  
to or from  
PCM subchannel position  
CFI time slot →  
PCM time slot →  
0001  
0011  
0010  
0111  
0110  
0101  
0100  
7
6
5
4
3
3
3
2
2
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
←→  
←→  
←→  
←→  
←→  
←→  
←→  
7
7
6
6
5
5
4
4
3
2
1
0
0
3
2
1
7
6
5
4
3
2
1
0
Semiconductor Group  
158  
PEB 2055  
PEF 2055  
Application Hints  
Examples  
In PCM mode 0 and CFI mode 0 the following connections shall be programmed:  
Upstream: CFI port 0, time slot 3, bits 1 … 0 to PCM port 0, time slot 4, bits 1 … 0  
W:MADR = 1001 0000B PCM time slot encoding, the subchannel position is  
defined by MACR:CMC3 … 0 = 0100  
W:MAAR = 1000 1001B CFI time slot encoding, the subchannel position is  
defined by CSCR:SC01 … 00 = 11  
W:MACR = 0111 0100B CM code for switching a 16 kbit/s/bits 1 … 0  
channel (0100)  
Upstream: CFI port 3, time slot 7, bits 3 … 2 to PCM port 0, time slot 4, bits 5 … 4  
W:MADR = 1001 0000B PCM time slot encoding, the subchannel position is  
defined by MACR:CMC3 … 0 = 0110  
W:MAAR = 1001 1111B CFI time slot encoding, the subchannel position is  
defined by CSCR:SC31 … 30 = 10  
W:MACR = 0111 0110B CM code for switching a 16 kbit/s, bits 3 … 2  
channel (0110)  
The following sequence sets transmit time slot 4 of PCM port 0 bits 5 … 4 and 1 … 0 to  
low impedance and bits 7 … 6 and 3 … 2 to high impedance:  
W:MADR = 0000 0101B bits 5, 4, 1, 0 to low Z and bits 7, 6, 3, 2 to high Z  
W:MAAR = 1001 0000B PCM time slot encoding  
W:MACR = 0110 0000B MOC code to access the tristate field  
Downstream: CFI port 2, time slot 7, bits 3 … 0 from PCM port 1, time slot 3, bits 7 … 4  
W:MADR = 0000 1011B PCM time slot encoding, the subchannel position is  
defined by MACR:CMC3 … 0 = 0011  
W:MAAR = 0001 1101B CFI time slot encoding, the subchannel position is  
defined by CSCR:SC21 … 20 = 01  
W:MACR = 0111 0011B CM code for switching a 32 kbit/s/bits 7 … 4  
channel (0011)  
Semiconductor Group  
159  
PEB 2055  
PEF 2055  
Application Hints  
Downstream: CFI port 2, time slot 10, bits 5 … 4 from PCM port 0, time slot 4, bits 7 … 6  
W:MADR = 0001 0000B PCM time slot encoding, the subchannel position is  
defined by MACR:CMC3 … 0 = 0111  
W:MAAR = 0010 1100B CFI time slot encoding, the subchannel position is  
defined by CSCR:SC21 … 20 = 01  
W:MACR = 0111 0111B CM code for switching a 16 kbit/s/bits 7 … 6  
channel (0111)  
Finally the CSCR register has to be programmed to define the subchannel positions at  
the CFI:  
W:CSCR = 1001 XX11B  
port 0: bits 1 … 0 or 3 … 0; port 1: not used in this  
example;  
port 2: bits 5 … 4 or 3 … 0; port 3: bits 3 … 2 or 7 … 4  
After these three programming steps, the EPIC memories will have the following content:  
Control Memory  
Data Field  
Data Memory  
Data Field  
CFI  
Frame  
PCM  
Frame  
Code Field  
Code Field  
0
0
P0, TS3  
Bits 1, 0  
0
0
1
1
0
1
0
0
1
1
0
0
0
0
1
1
0
0
0
0
0
0
0
0
Up-  
-
-
-
-
Up-  
stream  
0
1
0
1
P0, TS4  
stream  
P3, TS7  
Bits 3, 2  
127  
127  
0
0
P2, TS7  
Bits 3, 0  
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
1
1
0
0
0
1
0
1
0
P1, TS3  
Bits 7, 4  
Down-  
Down-  
stream  
P2, TS10  
Bits 5, 4  
stream  
P0, TS4  
Bits 7, 6  
127  
127  
ITD08072  
Figure 57  
Memory Content in Case of CFI - PCM Subchannel Connections  
Semiconductor Group  
160  
PEB 2055  
PEF 2055  
Application Hints  
5.4.3  
Loops  
Loops between time slots (or even subtime slots) of the CFI (CFI CFI) or the PCM  
interface (PCM PCM) can easily be programmed in the control memory. It is thus  
possible to establish individual loops for individual time slots on both interfaces without  
making external connections. These loops can serve for test purposes only or for real  
switching applications within the system. It should be noted that such a loop connection  
is always carried out over the opposite interface i.e. looping back a CFI time slot to  
another CFI time slot occupies a spare upstream PCM time slot and looping back a PCM  
time slot to another PCM time slot occupies a spare downstream and upstream CFI time  
slot. The required time slot on the opposite interface can however be switched to high  
impedance in order not to disturb the external line.  
5.4.3.1 CFI - CFI Loops  
For looping back a time slot of a CFI input port to a CFI output port, two connections must  
be programmed:  
A first connection switches the upstream CFI time slot to a spare PCM time slot. This  
connection is programmed like a normal CFI to PCM link, i.e the MADR contains the  
encoding for the upstream PCM time slot (U/D = 1) which is written to the upstream CM  
(MAAR contains the encoding for the upstream CFI time slot (U/D = 1)). If the data  
should also be transmitted at TxD#, the tristate field of that PCM time slot can be set to  
low impedance (transparent loop). If TxD# should be disabled, the tristate field of that  
PCM time slot can be set to high impedance (non-transparent loop).  
The second connection switches the “upstream” PCM time slot (contents of the  
upstream data memory) back to the downstream CFI time slot. This connection is  
programmed by using exactly the same MADR value as has been used for the first  
connection, i.e. the encoding for the spare upstream PCM time slot (with U/D = 1). This  
MADR value is written to the downstream CM (MAAR contains the encoding for the  
downstream CFI time slot (U/D = 0).  
The following example illustrates the necessary programming steps for establishing CFI  
to CFI loops.  
Semiconductor Group  
161  
 
PEB 2055  
PEF 2055  
Application Hints  
Example  
In PCM mode 0 and CFI mode 0 the following non-transparent CFI to CFI loop via PCM  
port 0, time slot 0 shall be programmed:  
Upstream: CFI port 2, time slot 4, bits 7 … 0 to PCM port 0, time slot 0, bits 7 … 0  
W:MADR = 1000 0000B PCM time slot encoding (pointer to upstream DM)  
W:MAAR = 1001 0100B CFI time slot encoding (address of upstream CM)  
W:MACR = 0111 0001B CM code for switching a 64 kbit/s/bits 7 … 0  
channel (0001)  
Downstream: CFI port 1, time slot 7, bits 7 … 0 from PCM port 0, time slot 0, bits 7 … 0  
W:MADR = 1000 0000B PCM time slot encoding (pointer to upstream DM)  
W:MAAR = 0001 1011B CFI time slot encoding (address of downstream CM)  
W:MACR = 0111 0001B CM code for switching a 64 kbit/s/bits 7 … 0  
channel (0001)  
The following sequence sets transmit time slot 0 of PCM port 0 to high impedance:  
W:MADR = 0000 0000B all bits to high Z  
W:MAAR = 1000 0000B PCM time slot encoding  
W:MACR = 0110 0000B MOC code to access the tristate field  
Semiconductor Group  
162  
PEB 2055  
PEF 2055  
Application Hints  
After these three programming steps, the EPIC memories will have the following  
contents:  
Control Memory  
Data Field  
Data Memory  
Data Field  
CFI  
Frame  
PCM  
Frame  
Code Field  
Code Field  
0
0
0
0
0
P0, TS0  
0
P2, TS4  
0
0
0
1
1 0 0 0 0 0 0 0  
Up-  
Up-  
stream  
stream  
127  
127  
0
0
Down-  
Down-  
stream  
stream  
P1, TS7  
0
0
0
1
1 0 0 0 0 0 0 0  
127  
127  
ITD08073  
Figure 58  
Memory Content in Case of a CFI CFI Loop  
Semiconductor Group  
163  
PEB 2055  
PEF 2055  
Application Hints  
5.4.3.2 PCM - PCM Loops  
For looping back a time slot of a PCM input port to a PCM output port, two connections  
must be programmed:  
The first connection switches the downstream PCM time slot to a spare CFI time slot.  
This connection is programmed like a normal PCM to CFI link, i.e the MADR contains  
the encoding for the downstream PCM time slot (U/D = 0) which is written to the  
downstream CM (MAAR contains the encoding for the downstream CFI time slot (U/D =  
0)). If the data should also be transmitted at DD# (transparent loop), the programming is  
performed with MACR:CMC3 … 0 = 0001 … 0111, the actual code depending on the  
required bandwidth. If DD# should be disabled (non-transparent loop), the programming  
is performed with MACR:CMC3 … 0 = 0000, the code for unassigned channels.  
The second connection switches the serial CFI time slot data back to the upstream PCM  
time slot. This connection is programmed by writing the encoded PCM time slot via  
MADR to the upstream CM. This “upstream” pointer must however have the MSB set  
to 0 (U/D = 0). This MADR value is written to the same spare CFI time slot as the PCM  
time slot had been switched to in the first step. Only that now the upstream CM is  
accessed (MAAR addresses the upstream CFI time slot (U/D = 1)).  
In contrast to the CFI PCM CFI loop, which is internally realized by extracting the  
CFI data out of the upstream data memory (see chapter 5.4.3.1), the PCM CFI →  
PCM loop is realized differently:  
The downstream PCM CFI connection switches the PCM data to the internal  
downstream serial CFI output. From this internal output, the data is switched to the  
upstream serial CFI input if the control memory of the corresponding upstream CFI time  
slot contains a pointer with a leading 0 (U/D = 0). However, this pointer (with U/D = 0)  
still points to the upstream data memory, i.e to an upstream PCM time slot.  
The following example illustrates the necessary programming steps for establishing  
PCM to PCM loops:  
Example  
In PCM mode 1 and CFI mode 0 the following non-transparent PCM to PCM loop via CFI  
port 1, time slot 4 shall be programmed:  
Downstream: CFI port 1, time slot 4, bits 7 … 0 from PCM port 0, time slot 13, bits 7 … 0  
W:MADR = 0001 1001B PCM time slot encoding (pointer to downstream DM)  
W:MAAR = 0001 0010B CFI time slot encoding (address of downstream CM)  
W:MACR = 0111 0000B CM code for unassigned channel (0000)  
Semiconductor Group  
164  
PEB 2055  
PEF 2055  
Application Hints  
Upstream: CFI port 1, time slot 4, bits 7 … 0 to PCM port 0, time slot 5, bits 7 … 0  
W:MADR = 0000 1001B PCM time slot encoding (pointer to “upstream” DM,  
loop switch (MSB = 0) activated)  
W:MAAR = 1001 0010B CFI time slot encoding (address of upstream CM)  
W:MACR = 0111 0001B CM code for switching a 64 kbit/s, bits 7 … 0  
channel (0001)  
The following sequence sets transmit time slot 5 of PCM port 0 to low impedance:  
W:MADR = 0000 1111B all bits to low Z  
W:MAAR = 1000 1001B PCM time slot encoding  
W:MACR = 0110 0000B MOC code to access the tristate field  
After these three programming steps, the EPIC memories will have the following  
contents:  
Control Memory  
Data Field  
Data Memory  
Data Field  
CFI  
Frame  
PCM  
Frame  
Code Field  
Code Field  
0
0
1
1
1
1
P0, TS5  
Up-  
Up-  
stream  
stream  
P1, TS4  
0
0
0
1
0 0 0 0 1 0 0 1  
127  
127  
0
0
Down-  
Down-  
stream  
stream  
P0, TS13  
0
0
0
0
0 0 0 1 1 0 0 1  
P1, TS4  
127  
127  
ITD08074  
Figure 59  
Memory Content in Case of a PCM PCM Loop  
Semiconductor Group  
165  
PEB 2055  
PEF 2055  
Application Hints  
5.4.4  
Switching Delays  
When a channel is switched from an input time slot (e.g. from the PCM interface) to an  
output time slot (e.g. to the CFI), it is sometimes useful to know the frame delay  
introduced by this connection. This is of prime importance for example if channels having  
a bandwidth of n × 64 kbit/s (e.g. H0 channels: 6 × 64 = 384 kbit/s) shall be switched by  
the EPIC. If all 6 time slots of an H0 channel are not submitted to the same frame delay,  
time slot integrity is no longer maintained.  
Since the EPIC has only a one frame buffer, the switching delay depends mainly on the  
location of the output time slot with respect to the input time slot. If there is “enough” time  
between the two locations, the EPIC switches the input data to the output data within the  
same frame (see figure 60 a)). If the time between the two locations is too small or if the  
output time slot is later in time than the input time slot, the data received in frame N will  
only be transmitted in frame N + 1 or even N + 2 (see figure 60 b)) and figure 60 c)).  
a) Switching Delay : 0 Frames  
N
N
N + 1  
N + 1  
N + 2  
N + 2  
Input Frame  
Output Frame  
b) Switching Delay : 1 Frames  
N
N + 1  
N + 1  
N + 2  
N + 2  
Input Frame  
N
Output Frame  
c) Switching Delay : 2 Frames  
N
N + 1  
N + 1  
N + 2  
N + 2  
Input Frame  
N
Output Frame  
ITD08075  
Figure 60  
Switching Delays  
Semiconductor Group  
166  
 
PEB 2055  
PEF 2055  
Application Hints  
The exact respective time slot positions where the delay skips from 0 frames to 1 frame  
and from 1 frame to 2 frames can be determined when having a closer look at the internal  
read and write cycles to the Data Memory.  
The next two figures show the internal timing characteristics for the access to the data  
memory (DM) of the EPIC. For simplicity, only the case where the PCM and CFI frames  
both start simultaneously at position “time slot 0, bit 7” is shown. Also, only the cases  
with 2, 4 and 8 × 1024 kbit/s data rates are shown. All other cases (different frame offsets  
and different data rates) can, however, be deduced by taking into account the respective  
frame positions, and, eventually, by taking into account a different RCL frequency.  
5.4.4.1 Internal Procedures at the Serial Interfaces  
The data is received and transmitted at the PCM and configurable interfaces in a serial  
format. Before being written to the DM, the data is converted into parallel format. The  
vertical arrows indicate the position in time where the incoming time slot data is written  
to the data memory. The writing to the DM is only possible during certain time intervals  
which are also indicated in the figures. For outgoing time slots, the data is first read in  
parallel format from the DM. This also is only possible during certain read cycles as  
indicated in the figures (vertical arrows). Before the time slot data is sent out, it must first  
be converted into serial format.  
The data contained in a time slot can be switched from an incoming time slot position to  
an outgoing time slot position within the same frame (0 frame delay) if the reading from  
the DM occurs after the writing to the DM. If the reading occurs before the writing, the  
data from the previous frame is taken, i.e. the frame delay is one frame.  
Semiconductor Group  
167  
PEB 2055  
PEF 2055  
Application Hints  
No Bit Shift at PCM and CFI Interface  
PCM Rate = 8 Mbit/s  
TS0  
TS1  
TS2  
TS3  
TS4  
TS5  
TS6  
TS7  
TS8  
TS9  
TS10  
TS11  
TS12  
TS13  
TS14  
TS15  
TS120 ...123 TS124...127  
TS0 ... 3 TS4... 7  
Write Cycles  
RXD3 RXD3  
RXD3 RXD3  
PCM Rate = 4 Mbit/s  
PCM Rate = 2 Mbit/s  
TS0  
TS1  
TS2  
TS3  
TS4  
TS5  
TS6  
TS7  
TS60 ... 63  
TS60... 63  
TS0 ... 3 TS0 ... 3  
Write Cycles  
Write Cycles  
RXD1 RXD3  
RXD1 RXD3  
TS0  
TS1  
TS2  
TS3  
TS30 ... 31 TS30 ... 31  
TS0 ... 1 TS0 ... 1  
RXD0 ... 1 RXD2 ... 3  
RXD0 ... 1 RXD2 ... 3  
Possible  
Write Cycles  
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0  
RCL = 4 MHz  
Possible  
Read Cycles  
Read Cycles  
TS2 TS3  
to DD0  
TS4 TS5  
to DD0  
TS6 TS7  
to DD0  
TS8 TS9  
to DD0  
TS10 TS11  
to DD0  
TS12 TS13  
to DD0  
TS14 TS15  
to DD0  
TS16 TS17  
to DD0  
CFI Rate  
=
8 Mbit/s  
TS0  
TS1  
TS2  
TS3  
TS4  
TS5  
TS6  
TS7  
TS8  
TS9  
TS10  
TS11  
TS12  
TS13  
TS14  
TS15  
TS2 TS3  
to DD0  
TS2 TS3  
to DD1  
TS4 TS5  
to DD0  
TS4 TS5  
to DD1  
TS6 TS7  
to DD0  
TS6 TS7  
to DD1  
TS8 TS9  
to DD0  
TS8 TS9  
to DD1  
CFI Rate  
CFI Rate  
=
=
4 Mbit/s  
TS0  
TS1  
TS2  
TS3  
TS4  
TS5  
TS6  
TS7  
TS2 TS3  
to DD0  
TS2 TS3  
to DD1  
TS2 TS3  
to DD2  
TS2 TS3  
to DD3  
TS4 TS5  
to DD0  
TS4 TS5  
to DD1  
TS4 TS5  
to DD2  
TS4 TS5  
to DD3  
2 Mbit/s  
ITT08076  
TS0  
TS1  
TS2  
TS3  
Figure 61  
Internal Timing Data Downstream  
Semiconductor Group  
168  
PEB 2055  
PEF 2055  
Application Hints  
No Bit Shift at PCM and CFI Interface  
CFI Rate = 8 Mbit/s  
TS15  
TS0  
TS1  
TS2  
TS3  
TS4  
TS5  
TS6  
TS7  
TS8  
TS9  
TS10  
TS11  
TS12  
TS13  
TS14  
TS30 TS31  
to DU0  
TS0 TS1  
to DU0  
TS2 TS3  
to DU0  
TS4 TS5  
to DU0  
TS6 TS7  
to DU0  
TS8 TS9  
to DU0  
TS10 TS11  
to DU0  
TS12 TS13  
to DU0  
CFI Rate = 4 Mbit/s  
CFI Rate = 2 Mbit/s  
TS0  
TS1  
TS2  
TS3  
TS4  
TS5  
TS6  
TS7  
TS30 TS31  
to DU0  
TS30 TS31  
to DU1  
TS0 TS1  
to DU0  
TS0 TS1  
to DU1  
TS2 TS3  
to DU0  
TS2 TS3  
to DU1  
TS4 TS5  
to DU0  
TS4 TS5  
to DU1  
TS0  
TS1  
TS2  
TS3  
TS30 TS31  
to DU0  
TS30 TS31  
to DU1  
TS30 TS31  
to DU2  
TS30 TS31  
to DU3  
TS0 TS1  
to DU0  
TS0 TS1  
to DU1  
TS0 TS1  
to DU2  
TS0 TS1  
to DU3  
Write Cycles  
Possible  
Write Cycles  
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0  
RCL = 4 MHz  
Possible  
Read Cycles  
TS16 ...19 TS20 ... 23  
TXD0 TXD0  
TS24 ... 27 TS28 ... 31  
TXD0 TXD0  
PCM Rate  
=
=
=
8 Mbit/s  
4 Mbit/s  
TS0  
TS1  
TS2  
TS3  
TS4  
TS5  
TS6  
TS7  
TS8  
TS9  
TS10  
TS11  
TS12  
TS13  
TS14  
TS15  
TS8 ...11 TS8 ...11  
TS12 ...15 TS12 ...15  
Read Cycles  
TS7  
TXD0 TXD2  
TXD0 TXD2  
PCM Rate  
PCM Rate  
TS0  
TS1  
TS2  
TS3  
TS4  
TS5  
TS6  
TS4 ... 5  
TS4 ... 5  
TS6 ... 7 TS6 ... 7  
TXD0...1 TXD2... 3  
TS1  
TXD0... 1 TXD2... 3  
TS3  
2 Mbit/s  
ITT08077  
TS0  
TS2  
Figure 62  
Internal Timing Data Upstream  
Semiconductor Group  
169  
PEB 2055  
PEF 2055  
Application Hints  
5.4.4.2 How to Determine the Delay  
In order to determine the switching delay for a certain configuration, the following rules  
have to be applied with respect to the timing diagram:  
Data Downstream  
– At the PCM interface the incoming data (data downstream) is written to the RAM after  
the beginning of:  
time slot: 2 × n for mode 0  
time slot: 4 × n for mode 1  
time slot: 8 × n for mode 2  
Note: n is an integer number.  
The point of time to write the data to the RAM is RCL period 0, 4, 7 for the PCM interface  
Due to internal delays, the RCL period at the beginning of time slot 2 × n (for mode 0),  
4 × n (for mode 1), 8 × n for mode 2) is not a valid write cycle.  
– At the CFI interface the data, that is to be transmitted on:  
TS 2 × n + 4 ... 2 × n + 5 (CFI mode 0)  
TS 2 × n + 6 ... 2 × n + 7 (CFI mode 1)  
TS 2 × n + 10 ... 2 × n + 11 (CFI mode 2)  
is read out of the RAM as soon as time slot:  
2 × n + 1 (for mode 0)  
2 × n + 3 (for mode 1)  
2 × n + 7 (for mode 2) is transmitted  
Note: n is an integer number; the time slot number can’t exceed the max. number of TS.  
The point of time to read the data from the RAM is RCL period 5 and 6 for the CFI  
interface.  
The data is read out of the RAM in several steps in the following order:  
CFI mode 0: - even TS for DD0, odd TS for DD0,  
even TS for DD1, odd TS for DD1,  
even TS for DD2, odd TS for DD2,  
even TS for DD3, odd TS for DD3  
CFI mode 1: - even TS for DD0, odd TS for DD0,  
even TS for DD1, odd TS for DD1  
CFI mode 2: - even TS for DD0, odd TS for DD0  
Semiconductor Group  
170  
PEB 2055  
PEF 2055  
Application Hints  
Data Upstream  
– At the CFI interface the incoming data (data upstream) is written to the RAM starting  
with DU0 at the beginning of:  
time slot: 2 × n for CFI mode 0  
time slot: 2 × n for CFI mode 1  
time slot: 2 × n for CFI mode 2  
Note: n is an integer number; the time slot number can’t exceed the max. number of TS.  
The point of time to write the data to the RAM is RCL period 1 and 3 for the CFI interface  
– At the PCM interface the data, that is to be transmitted on  
TS 2 × n + 4 ... TS 2 × n + 5 (for PCM mode 0)  
TS 4 × n + 8 ... TS 4 × n + 11 (for PCM mode 1)  
TS 8 × n + 16 ... TS 8 × n + 23 (for PCM mode 2)  
is read out of the RAM as soon as time slot:  
2 × n (for PCM mode 0)  
4 × n + 1 (for PCM mode 1)  
8 × n + 3 (for PCM mode 2) is transmitted  
Note: n is an integer number; the time slot number can’t exceed the max. number of TS.  
The point of time to read the data from the RAM, is RCL period 0, 4, 7 for the PCM  
interface  
Due to internal delays, the RCL period at the beginning of time slot 2 × n + 1 (for PCM 0),  
4 × n + 2 (for PCM mode1), 8 × n + 4 for PCM mode 2) is no valid write cycle.  
The data is read out of the RAM in two steps:  
PCM mode 0: in a block of 2 TS for TXD0 … 1 then for TXD2 … 3  
PCM mode 1: in a block of 4 TS for TXD0 then for TXD2  
PCM mode 2: in halfs of a 8 TS blocks for TXD0 (first half) then for TXD0  
(second half)  
Semiconductor Group  
171  
PEB 2055  
PEF 2055  
Application Hints  
Considering a Bit Shift  
A bit shift will also influence switching delays.  
If the PCM frame is shifted relative to the frame signal, proceed as indicated below:  
Shift only the PCM part of the figure (‘PCM line’ with the time slot numbers), relative to  
the rest of the figure, to the left.  
If the CFI frame is shifted relative to the framing signal, then the CFI part, including the  
figure of the RCL, and all read and write cycle points are shifted left relative to the PCM  
part. If CBSR:CDS = 000 or 001, then the frame CFI part is shifted to the right.  
The figure so produced should be processed as previously described.  
Note: If a bit shift has been installed while the PCM interface is already in the  
synchronous state, the following procedure has to be applied:  
1.) Unsynchronize the PCM interface by writing an invalid number  
to register PBNR  
2.) Resynchronize the PCM interface by writing the correct number to PBNR  
5.4.4.3 Example: Switching of Wide Band ISDN Channels with the EPIC®  
The EPIC shall switch 6 B-channels of a digital subscriber to an 8 MBit/s PCM highway  
guaranteeing frame integrity. The system uses the IOM-2 interface to adapt to a multiple  
S-interface. No bit shift has to be applied. The tables below will help to determine the  
combination of input/output ports and time slots, that meet the requirements.  
Semiconductor Group  
172  
PEB 2055  
PEF 2055  
Application Hints  
Figure 63  
Calculation of Downstream Switching Delay  
Semiconductor Group  
173  
PEB 2055  
PEF 2055  
Application Hints  
Figure 64  
Calculation of Upstream Switching Delay  
Semiconductor Group  
174  
PEB 2055  
PEF 2055  
Application Hints  
5.5  
Preprocessed Channels  
The configurable interface (CFI) is at first sight a time slot oriented serial interface similar  
to the PCM interface: a CFI frame contains a number of time slots which can be switched  
to the PCM interface. But in addition to the switching functions, the CFI time slots can  
also individually be configured as preprocessed channels. In this case, the contents of  
a CFI time slot are directly, or after an eventual preprocessing, exchanged with the µP  
interface. The main application is the realization of IOM (ISDN Oriented Modular) and  
SLD (Subscriber Line Data) interfaces for the connection of subscriber circuits such as  
layer-1 transceivers (ISDN line cards) or codec filter devices (analog line cards). Also  
refer to chapter 5.1.1.  
The preprocessing functions can be divided into 2 categories:  
Monitor/Feature Control (MF) Channels  
The monitor channel in IOM and the feature control channel in SLD applications are  
handled by the MF handler. This MF handler consists of a 16 byte bidirectional FIFO  
providing intermediate storage for the messages to be transmitted or received. Internal  
microprograms can be executed in order to control the communication with the  
connected subscriber circuit according to the IOM or SLD protocol. The exchange of  
individual data is carried out with only one channel at a time. The MF handler must  
therefore be pointed to that particular subscriber address (CFI time slot).  
Control/Signaling (CS) Channels  
The access to the Command/Indication (C/I) channel of an IOM and to the signaling  
(SIG) channel of an SLD interface is realized by reading or writing to the corresponding  
control memory (CM) locations. In upstream direction, a change detection logic  
supervises the received C/I or SIG values on all CS channels and reports all changes  
via interrupt to the µP.  
The MF and CS channel functions are inseparably linked to each other such that an MF  
channel must always be followed by a CS channel in the next following CFI time slot. An  
MF channel must furthermore, be located on an even CFI time slot, the associated CS  
channel must consequentially be always located on the following odd time slot.  
Semiconductor Group  
175  
PEB 2055  
PEF 2055  
Application Hints  
5.5.1  
Initialization of Preprocessed Channels  
The initialization of preprocessed channels is usually performed after the CM reset  
sequence during device initalization. Resetting the CM sets all CFI time slots to  
unassigned channels (CM code ‘0000’). The initialization of preprocessed channels  
consists of writing appropriate CM codes to those CFI time slots that should later be  
handled by the CS or MF handler.  
The initialization or re-initialization of preprocessed channels can of course also be  
carried out during the operational phase of the device.  
If the CFI shall be operated as a standard IOM-2 interface, for example, the CFI frame  
consists of 32 time slots, numbered from 0 to 31 (see figure 22).  
The B channels occupy time slots 0 and 1 (IOM channel 0), 4 and 5 (IOM channel 1), 8  
and 9 (IOM channel 2), and so on. The B channels are normally switched to the PCM  
interface and are programmed only if the actual switching function is required.  
The monitor, D and C/I channels occupy time slots 2 and 3 (IOM channel 0), 6 and 7  
(IOM channel 1), 10 and 11 (IOM channel 2), and so on. These time slots must be  
initialized in both upstream and downstream directions for the desired functionality. In  
order to speed up this initialization, the EPIC can be set into the CM initialization mode  
as described in chapter 5.3.2.  
There are several options available to cover the different applications like switched D  
channel, 6 bit signaling, etc. It should be noted that each pair of time slots can  
individually be set for a specific application and that the up- and downstream directions  
can also be set differently, if required.  
Decentral D-Channel Handling Scheme  
This option applies for IOM channels where the even time slot consists of an 8 bit  
monitor channel and the odd time slot of a 2 bit D-Channel followed by a 4 bit C/I channel  
followed by the 2 monitor handshake bits MR and MX.  
The monitor channel is handled by the MF handler according to the selection of  
handshake or non-handshake protocol. If the handshake option is selected (IOM-2), the  
MF handler controls the MR and MX bits according to the IOM-2 specification. If the no  
handshake option is selected (IOM-1), the MF handler sets both MR and MX bits to  
logical 1; the MR and MX bit positions can then, if required, be accessed together with  
the 4 bit C/I field via the even control memory address.  
The D-Channel is not processed at all, i.e. the input in upstream direction is ignored and  
the output in downstream direction is set to high impedance. External D-Channel  
controllers, e.g. 2 × IDECs PEB 2075, can then be connected to each IOM interface in  
order to realize decentral D-Channel processing.  
The 4 bit C/I channel can be accessed by the µP for controlling layer-1 devices. In  
upstream direction each change in the C/I value is reported by interrupt to the µP and the  
CFI time slot address is stored in the CIFIFO (refer to chapter 5.5.2). A C/I change is  
Semiconductor Group  
176  
 
PEB 2055  
PEF 2055  
Application Hints  
detected if the value of the current CFI frame is different from the value of the previous  
frame i.e. after at most 125 µs.  
To initialize two consecutive CFI time slots for the decentral D Channel handling  
scheme, the CM codes as given in table 27 must be used.  
Table 27  
CM Address  
CM Code  
CM Data  
Even time slot downstream 1000  
11 C/I 11B  
Odd time slot downstream  
Even time slot upstream  
Odd time slot upstream  
1011  
1000  
0000  
XXXXXXXXB  
XX C/I XXB  
XXXXXXXXB  
Application hint:  
If the D-Channel is idle and if it is required to transmit a 2 bit idle  
code in the D-Channel (e.g. during the layer-1 activation or for  
testing purposes), the 6 bit signaling handling scheme can be  
selected for the downstream direction. The 2 D bits together with  
the 4 C/I bits can then be written to via the even control memory  
address. If the high impedance state is needed again, the  
decentral D-Channel scheme has to be selected again.  
Example  
In CFI mode 0, time slots 2 and 3 of port 3 are to be initialized for decentral D-Channel  
handling:  
W:MADR = 1100 0011B  
W:MAAR = 0000 1110B  
W:MACR = 0111 1000B  
; C/I value ‘0000’  
; downstream even TS, port 3 time slot 2  
; write CM code + data fields, CM code ‘1000’  
W:MADR = XXXX XXXXB  
W:MAAR = 0000 1111B  
W:MACR = 0111 1011B  
; don’t care  
; downstream odd TS, port 3 time slot 3  
; write CM code + data fields, CM code ‘1011’  
W:MADR = 1111 1111B  
W:MAAR = 1000 1110B  
W:MACR = 0111 1000B  
; expected C/I value ‘1111’  
; upstream even TS, port 3 time slot 2  
; write CM code + data fields, CM code ‘1000’  
W:MADR = XXXX XXXXB  
W:MAAR = 1000 1111B  
W:MACR = 0111 0000B  
; don’t care  
; upstream odd TS, port 3 time slot 3  
; write CM code + data fields, CM code ‘0000’  
Semiconductor Group  
177  
 
PEB 2055  
PEF 2055  
Application Hints  
After these programming steps, the control memory will have the following content:  
Control Memory  
CFI  
Frame  
Code Field  
Data Field  
C/I Value  
Up-  
0
stream  
P0, TS2  
P0, TS3  
1
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
X
X
X
X
X
X
X
X
127  
Down-  
stream  
0
C/I Value  
P0, TS2  
P0, TS3  
1
1
0
0
0
1
0
1
1
1
0
0
0
0
1
1
X
X
X
X
X
X
X
X
127  
ITD08080  
Figure 65  
Control Memory Contents for Decentral D-Channel Handling  
Central D-Channel Handling Scheme  
This option applies for IOM channels where the even time slot consists of an 8 bit monitor  
channel and the odd time slot of a 2 bit D-Channel followed by a 4 bit C/I channel  
followed by the 2 monitor handshake bits MR and MX.  
The monitor channel is handled by the MF handler according to the selected protocol,  
handshake or non-handshake. If the handshake option is selected (IOM-2), the MF  
handler controls the MR and MX bits according to the IOM-2 specification. If the  
non-handshake option is selected (IOM-1), the MF handler sets both MR and MX bits to  
Semiconductor Group  
178  
PEB 2055  
PEF 2055  
Application Hints  
logical 1; the MR and MX bit positions can then, if required, be accessed together with  
the 4 bit C/I field via the even control memory address.  
The D-Channel can be switched as a 16 kbit/s channel to and from the PCM interface in  
order to be handled by a centralized D-Channel processing unit.  
The 4 bit C/I channel can be accessed by the µP for controlling layer-1 devices. In the  
upstream direction each change in the C/I value is reported by interrupt to the µP and  
the CFI time slot address is stored in the CIFIFO (refer to chapter 5.5.2). A C/I change  
is detected if the value of the current CFI frame is different from the value of the previous  
frame i.e. after at most 125 µs.  
To initialize two consecutive CFI time slots for the decentral D-Channel handling  
scheme, the CM codes as given in table 28 must be used.  
Table 28  
CM Address  
CM Code  
CM Data  
Even time slot downstream 1010  
11 C/I 11B  
Odd time slot downstream  
Even time slot upstream  
Odd time slot upstream  
Switching code  
1000  
Switching code  
Pointer to PCM TS  
XX C/I XXB  
Pointer to PCM TS  
The switching codes specify the PCM subtime slot positions of the 16 kbit/s transfer.  
Note that the 2 D bits are always located on bits 7 … 6 of a CFI time slot, the  
CSCR:SC#1, SC#0 bits must therefore be set to 00 (see chapter 5.4.2).  
Table 29  
Transferred Channel PCM Downstream CM Codes  
Bit Positions  
Upstream CM Codes  
Unassigned channel  
16 kbit/s/ bits 7 … 6  
16 kbit/s/ bits 5 … 4  
16 kbit/s/ bits 3 … 2  
16 kbit/s/ bits 1 … 0  
10111)  
0111  
0110  
0101  
0100  
0000  
0111  
0110  
0101  
0100  
1)  
This code sets the D bits to high impedance  
Semiconductor Group  
179  
 
PEB 2055  
PEF 2055  
Application Hints  
Application hints: 1) If the D channel is idle and if it is required to transmit a 2 bit idle  
code in the D channel (e.g. during the layer-1 activation or for  
testing purposes), the 6 bit signaling handling scheme can be  
selected for the downstream direction. The 2 D bits together with  
the 4 C/I bits can then be written to via the even control memory  
address. If the high impedance state is needed again, the  
decentral D channel scheme has to be selected again.  
2) The central D channel scheme has primarily been designed to  
switch the 16 kbit/s D channel to the PCM interface and to process  
the C/I channel by the local µP. For some applications however, it  
is advantageous to switch the 2 D bits together with the 4 C/I bits  
transparently to and from the PCM interface. The monitor channel  
shall, however, still be handled by the internal MF handler. This  
function might be useful if two layer-1 transceivers, operated in  
“Repeater Mode”, shall be connected via a PCM link. For these  
applications, the odd control memory address is written with the  
64 kbit/s switching code ‘0001’, the CM data field pointing to the  
desired PCM time slot. Since also the MR and MX bits are being  
switched, these must be carefully considered: in upstream  
direction the two least significant bits of the PCM time slot can be  
set to high impedance via the tristate field; in downstream direction  
the two least significant bits of the PCM time slot must be received  
at a logical 1 level since these bits will be logical ANDed at the CFI  
with the downstream MR and MX bits generated by the MF  
handler.  
Example  
In CFI and PCM modes 0, CFI time slots 10 and 11 of port 1 shall be initialized for central  
D channel handling, the downstream D channel shall be switched from PCM port 0, TS5,  
bits 5 … 4 and the upstream D channel shall be switched to PCM port 2, TS8, bits 3 … 2:  
W:MADR = 1100 0011B  
W:MAAR = 0010 1010B  
W:MACR = 0111 1010B  
; C/I value ‘0000’  
; downstream even TS, port 1 time slot 10  
; write CM code + data fields, CM code ‘1010’  
W:MADR = 0001 0001B  
W:MAAR = 0010 1011B  
W:MACR = 0111 0110B  
; pointer to PCM port 0, TS5  
; downstream odd TS, port 1 time slot 11  
; write CM code + data fields, CM code ‘0110’  
W:MADR = 1111 1111B  
W:MAAR = 1010 1010B  
W:MACR = 0111 1000B  
; expected C/I value ‘1111’  
; upstream even TS, port 1 time slot 10  
; write CM code + data fields, CM code ‘1000’  
Semiconductor Group  
180  
PEB 2055  
PEF 2055  
Application Hints  
W:MADR = 1010 0100B  
W:MAAR = 1010 1011B  
W:MACR = 0111 0101B  
; pointer to PCM port 2, TS8  
; upstream odd TS, port 1 time slot 11  
; write CM code + data fields, CM code ‘0101’  
W:MADR = 0000 0010B  
W:MAAR = 1010 0100B  
W:MACR = 0110 0000B  
; set bits 3 … 2 to low Z and rest of time slot to high Z  
; pointer to PCM port 2, TS8  
; write DM CF, single channel tristate command  
After these programming steps, the EPIC memory will have the following contents:  
Control Memory  
Data Field  
Data Memory  
Data Field  
CFI  
Frame  
PCM  
Frame  
Code Field  
Code Field  
Up-  
0
0
stream  
C/I Value  
Up-  
stream  
P1, TS10  
P1, TS11  
1
0
0
1
0
0
0
1
1
1
1
0
1
1
1
0
1
1
1
0
1
1
1
0
P2, TS8  
Bits 3, 2  
0
0 1 0  
127  
127  
Down-  
0
0
stream  
C/I Value  
P0, TS5  
Bits 5, 4  
Down-  
stream  
P1, TS10  
P1, TS11  
1
0
0
1
1
1
0
0
1
0
1
0
0
0
0
1
0
0
0
0
1
0
1
1
127  
127  
ITD08081  
Figure 66  
Control Memory Contents for Central D-Channel Handling  
Semiconductor Group  
181  
PEB 2055  
PEF 2055  
Application Hints  
6-Bit Signaling Channel Scheme  
This option is intended for IOM channels where the even time slot consists of an 8 bit  
monitor channel and the odd time slot of a 6 bit signaling channel followed by the  
2 monitor handshake bits MR and MX.  
The monitor channel is handled by the MF handler according to the selected protocol,  
handshake or non-handshake. If the handshake option is selected (IOM-2), the MF  
handler controls the MR and MX bits according to the IOM-2 specification. If the  
non-handshake option is selected (IOM-1), the MF handler sets both MR and MX bits to  
logical 1; the MR and MX bit positions can then, if required, be accessed together with  
the 6 bit SIG field via the even control memory address.  
The 6 bit SIG channel can be accessed by the µP for controlling codec filter devices. In  
upstream direction each valid change in the SIG value is reported by interrupt to the µP  
and the CFI time slot address is stored in the CIFIFO (refer to chapter 5.5.2). The  
change detection mechanism consists of a double last look logic with a programmable  
period.  
To initialize two consecutive CFI time slots for the 6 bit signaling channel scheme, the  
CM codes as given in table 30 must be used:  
Table 30  
CM Address  
CM Code  
CM Data  
Even time slot downstream 1010  
SIG 11B  
Odd time slot downstream  
Even time slot upstream  
Odd time slot upstream  
1011  
1010  
1010  
XXXXXXXXB  
actual value XXB  
stable value XXB  
Application hint: For some applications it is useful to switch the 6 SIG bits transparently  
to and from the PCM interface. The monitor channel shall, however,  
still be handled by the internal MF handler. For this purpose, a slightly  
modified central D channel scheme can be used. This mode, which  
has primarily been designed to switch the 16 kbit/s D channel to the  
PCM interface, can be modified as follows: the odd control memory  
address is written with the 64 kbit/s switching code “0001”, the CM  
data field pointing to the desired PCM time slot. Since the MR and MX  
bits are being switched, these must be carefully considered: in  
upstream direction the two least significant bits of the PCM time slot  
can be set to high impedance via the tristate field; in downstream  
direction the two least significant bits of the PCM time slot must be  
received at a logical 1 level since these bits will be logical ANDed at  
the CFI with the downstream MR and MX bits generated by the MF  
handler.  
Semiconductor Group  
182  
 
PEB 2055  
PEF 2055  
Application Hints  
Example  
In CFI mode 0, time slots 2 and 3 of port 0 shall be initialized for 6 bit signaling channel  
handling:  
W:MADR = 0100 0111B  
W:MAAR = 0000 1000B  
W:MACR = 0111 1010B  
; SIG value “010001”  
; downstream even TS, port 0 time slot 2  
; write CM code + data fields, CM code “1010”  
W:MADR = XXXX XXXXB  
W:MAAR = 0000 1001B  
W:MACR = 0111 1011B  
; don’t care  
; downstream odd TS, port 0 time slot 3  
; write CM code + data fields, CM code “1011”  
W:MADR = 1101 1111B  
W:MAAR = 1000 1000B  
W:MACR = 0111 1010B  
; expected SIG value “110111”  
; upstream even TS, port 0 time slot 2  
; write CM code + data fields, CM code “1010”  
W:MADR = 1101 1111B  
W:MAAR = 1000 1001B  
W:MACR = 0111 1010B  
; expected SIG value “110111”  
; upstream odd TS, port 0 time slot 3  
; write CM code + data fields, CM code “1010”  
Semiconductor Group  
183  
PEB 2055  
PEF 2055  
Application Hints  
After these programming steps, the EPIC memory will have the following contents:  
Control Memory  
CFI  
Frame  
Code Field  
Data Field  
Up-  
0
stream  
SIG Value  
P0, TS2  
P0, TS3  
1
1
0
0
1
1
0
0
1
1
1
1
0
0
1
1
1
1
1
1
1
1
1
1
Actual Value  
Stable Value  
127  
Down-  
stream  
0
SIG Value  
P0, TS2  
P0, TS3  
1
1
0
0
1
1
0
1
0
1
0
0
0
1
1
1
X
X
X
X
X
X
X
X
127  
ITD08082  
Figure 67  
Control Memory Contents for 6-Bit Signaling Channel Handling  
Semiconductor Group  
184  
PEB 2055  
PEF 2055  
Application Hints  
8-Bit Signaling Scheme  
This option is intended for SLD channels where the even time slot consists of an 8 bit  
feature control channel and the odd time slot of an 8 bit signaling channel.  
The feature control channel is handled by the MF handler according to the selected  
protocol, handshake or non-handshake. Note that only the non-handshake mode makes  
sense in SLD applications.  
The 8 bit SIG channel can be accessed by the µP for controlling codec filter devices. In  
upstream direction each valid change in the SIG value is reported by interrupt to the µP  
and the CFI time slot address is stored in the CIFIFO (refer to chapter 5.5.2). The  
change detection mechanism consists of a double last look logic with a programmable  
period.  
To initialize two consecutive CFI time slots for the 8 bit signaling channel scheme, the  
CM codes as given in table 31 must be used:  
Table 31  
CM Address  
CM Code  
CM Data  
Even time slot downstream 1010  
SIGB  
Odd time slot downstream  
Even time slot upstream  
Odd time slot upstream  
1011  
1011  
1011  
XXXXXXXXB  
actual valueB  
stable valueB  
Example  
In CFI mode 3, downstream time slots 2 and 3 and upstream time slots 6 and 7 of port  
0 shall be initialized for 8 bit signaling channel handling:  
W:MADR = 0100 0101B  
W:MAAR = 0001 0000B  
W:MACR = 0111 1011B  
; SIG value “0100 0101”  
; downstream even TS, port 0 time slot 2  
; write CM code + data fields, CM code “1011”  
W:MADR = XXXX XXXXB  
W:MAAR = 0001 0001B  
W:MACR = 0111 1011B  
; don’t care  
; downstream odd TS, port 0 time slot 3  
; write CM code + data fields, CM code “1011”  
W:MADR = 1101 0110B  
W:MAAR = 1011 0000B  
W:MACR = 0111 1011B  
; expected SIG value “1101 0110”  
; upstream even TS, port 0 time slot 6  
; write CM code + data fields, CM code “1011”  
W:MADR = 1101 0110B  
W:MAAR = 1011 0001B  
W:MACR = 0111 1011B  
; expected SIG value “1101 0110”  
; upstream odd TS, port 0 time slot 7  
; write CM code + data fields, CM code “1011”  
Semiconductor Group  
185  
 
PEB 2055  
PEF 2055  
Application Hints  
Summary of “Preprocessed Channel” Codes  
Even Control Memory Address  
MAAR = 0......0  
Odd Control Memory Address  
MAAR = 0......1  
Output at the Configurable Interface  
Downstream Preprocessed Channels  
Even Time-Slot Odd Time-Slot  
DD Application  
Code Field  
Data Field  
Code Field  
Data Field  
MACR = 0111...  
MADR = ......  
MACR = 0111...  
MADR = ......  
Decentral  
D Channel  
Handling  
m m m m m m m m  
Monitor Channel  
-
-
C/I  
m m  
1
1
0
0
0
1
0
0
1
1
1
1
C/I  
C/I  
1
1
1
1
1
0
1
1
X X X X X X X X  
Control Channel  
Central  
D Channel  
Handling  
PCM Code for  
a 2 Bit Sub.  
Time-Slot  
m m m m m m m m D D  
C/I  
m m  
Pointer to a PCM Time-Slot  
Monitor Channel  
Control Channel  
6 Bit  
Signaling  
(e.g. analog  
m m m m m m m m  
Monitor Channel  
SIG  
m m  
1
1
0
0
1
1
0
0
SIG  
1
1
1
1
0
0
1
1
1
1
X
X
X
X
X
X
X X  
X X  
X
X
X
X
X
X
Control Channel  
IOM R  
)
8 Bit  
Signaling  
(e.g. SLD)  
m m m m m m m m  
SIG  
SIG  
Feature Control Channel Signaling Channel  
Even Control Memory Address  
MAAR = 1......0  
Odd Control Memory Address  
MAAR = 1......1  
Input from the Configurable Interface  
Upstream Preprocessed Channels  
DD Application  
Code Field  
Data Field  
MADR = ......  
Code Field  
Data Field  
MADR = ......  
Even Time-Slot  
Odd Time-Slot  
MACR = 0111...  
MACR = 0111...  
Decentral  
D Channel  
Handling  
m m m m m m m m  
Monitor Channel  
-
-
C/I  
m m  
1
1
0
0
0
0
0
0
1
1
1
1
C/I  
C/I  
1
1
1
1
0
0
0
0
X
X
X
X X  
X
X
X
Control Channel  
Central  
D Channel  
Handling  
PCM Code for  
a 2 Bit Sub.  
Time-Slot  
m m m m m m m m D D  
C/I  
m m  
Pointer to a PCM Time-Slot  
Monitor Channel  
Control Channel  
6 Bit  
Signaling  
(e.g. analog  
m m m m m m m m  
Monitor Channel  
SIG  
m m  
1
1
0
0
1
1
0
1
SIG Actual Value  
X
X
1
1
0
0
1
1
0
1
SIG Stable Value  
X X  
Control Channel  
IOM R  
)
8 Bit  
Signaling  
(e.g. SLD)  
m m m m m m m m  
SIG  
SIG Actual Value  
SIG Stable Value  
Feature Control Channel Signaling Channel  
m : Monitor channel bits, these bits are treated by the monitor/feature control handler  
: Inactive sub. time-slot, in downstream direction these bits are tristated (OMDR : COS = 0) or set to logical 1(OMDR : COS = 1)  
-
C/I : Command/Indication channel, these bits are exchanged between the CFI in/output and the CM data field. A change of  
the C/I bits in upstream direction causes an interrupt (ISTA : SFI). The address of the change is stored in the CIFIFO  
D : D channel, these D channel bits are transparently switched to and from the PCM interface.  
SIG : Signaling Channel, these bits are exchanged between the CFI in/output and the CM data field. The SIG value which  
actual value was present in the last frame is stored as the actual value in the even address CM location. The stable value is updated  
stable value if a valid change in the actual value has been detected according to the last look algorithm. A change of the SIG stable  
value in upstream direction causes an interrupt (ISTA : CFI).The address of the change is stored in the CIFIFO.  
ITD09544  
Figure 68  
Pre-processed Channel Codes  
Semiconductor Group  
186  
PEB 2055  
PEF 2055  
Application Hints  
5.5.2  
Control/Signaling (CS) Handler  
If the configurable interface (CFI) of the EPIC is operated as IOM or SLD interface, it is  
necessary to communicate with the connected subscriber circuits such as layer-1  
transceivers (ISDN line cards) or codec filter devices (analog line cards) over the  
Command/Indication (C/I) or the signaling (SIG) channel. In order to simplify this task the  
EPIC has implemented the Control/Signaling Handler (CS Handler).  
In downstream direction, the 4, 6 or 8 bit C/I or SIG value can simply be written to the  
Control Memory data field which will then be repeatedly transmitted in every frame to the  
subscriber circuit until a new value is loaded.  
Note that the downstream C/I or SIG value must always be written to the even CM  
address in order to be transmitted in the subsequent odd CFI time slot!  
In upstream direction a change detection mechanism is active to search for changes in  
the received C/I or SIG values. Upon a change, the address of the involved subscriber  
is stored in a 9 byte deep FIFO (CIFIFO) and an interrupt (ISTA:SFI) is generated. The  
µP can then first determine the CM address by reading the FIFO before reading the new  
C/I or SIG value out of the Control Memory. The address FIFO serves to increase the  
latency time for the µP to react to SFI interrupts. If several C/I or SIG changes occur  
before the µP executes the SFI interrupt handling routine, the addresses of the first  
9 changes are stored in the CIFIFO and the corresponding C/I or SIG values are stored  
in the control memory (CM). If more than 9 changes occur before the µP reads the  
CIFIFO, these additional changes are no longer updated in the control memory. This is  
to prevent any loss of change information. These additional changes remain pending at  
the serial interface. As soon as the µP reads the CIFIFO, and thus, empties locations of  
the FIFO, these pending changes are sequentially written to the CM and the  
corresponding addresses to the FIFO. It is thus ensured that no change information is  
lost even if, for example, all 32 subscribers simultaneously generate a change in their  
C/I or SIG channel!  
CFI time slots which should be processed by the CS handler must first be initialized as  
MF/CS channels with appropriate codes in the Control Memory code field (refer to  
chapter 5.5.1).  
Semiconductor Group  
187  
PEB 2055  
PEF 2055  
Application Hints  
5.5.2.1 Registers used in Conjunction with the CS Handler  
In detail, the following register bits are used in conjunction with the CS handler:  
Signaling FIFO  
read  
reset value:  
0XXXXXXXB  
bit 7  
bit 0  
CIFIFO  
SBV  
SAD6  
SAD5  
SAD4  
SAD3  
SAD2  
SAD1  
SAD0  
The 9 byte deep CIFIFO stores the addresses of CFI time slots in which a C/I and/or a  
SIG value change has taken place. This address information can then be used to read  
the actual C/I or SIG value from the Control Memory.  
SBV:  
Signaling Byte Valid; if SBV = 1, the SAD6 … 0 bits indicate a valid  
subscriber address. The polarity of SBV is chosen such that the  
whole 8 bits of the CIFIFO can be copied to the MAAR register in  
order to read the upstream C/I or SIG value from the Control Memory.  
SAD6 … 0:  
Subscriber Address bits 6 … 0; The CM address which corresponds  
to the CFI time slot where a C/I or SIG value change has taken place  
is encoded in these bits. For C/I channels SAD6 … 0 point to an even  
CM address (C/I value), for SIG channels SAD6 … 0 point to an odd  
CM address (stable SIG value).  
Timer Register  
write  
reset value:  
00H  
bit 7  
bit 0  
TVAL6 TVAL5 TVAL4 TVAL3 TVAL2 TVAL1 TVAL0  
TIMR  
SSR  
The EPIC timer can be used for 3 different purposes: timer interrupt generation  
(ISTA:TIG), FSC multiframe generation (CMD2:FC2 … 0 = 111), and last look period  
generation.  
In case of last look period generation, the following functions are provided:  
SSR:  
Signaling Sampling Rate; If SSR = 1, the last look period is fixed to  
125 µs, i.e. the timer is not used at all for the last look logic. The value  
programmed to TVAL has then no influence on the last look period.  
The timer can then still be used for timer interrupt generation, and/or  
FSC multiframe generation, with a period as defined by TVAL6 … 0.  
If SSR = 0, the last look period is defined by TVAL6 … 0. Note that if  
the timer is used, it must also be started with CMDR:ST = 1.  
Semiconductor Group  
188  
 
PEB 2055  
PEF 2055  
Application Hints  
TVAL6 … 0:  
Timer Value bits 6 … 0; the timer period, equal to  
(1 + TVAL6 … 0) × 250 µs, is programmed here. It can thus be  
adjusted within the range of 250 µs up to 32 ms.  
The timer is started as soon as CMDR:ST is set to 1 and stopped by writing the TIMR  
register or by selecting OMDR:OMS0 = 0.  
If the timer is used to generate the last look period, it can still be used for timer interrupt  
generation and/or FSC multiframe generation if it is acceptable that all three applications  
use the same timer value.  
Command Register  
write  
reset value:  
00H  
bit 7  
bit 0  
MFT0 MFSO MFFR  
CMDR  
0
ST  
TIG  
CFR  
MFT1  
Writing a logical 1 to a CMDR register bit starts the respective operation.  
The signaling handler uses two command bits:  
ST:  
Start Timer; must be set to 1 if the last look period is defined by  
TIMR:TVAL6 … 0, i.e. if TIMR:SSR = 0. Note that if TIMR:SSR = 1,  
the timer need not be started.  
CFR:  
CIFIFO Reset; setting CFR to logical 1 resets the signaling FIFO  
within 2 RCL periods, i.e. all entries and the ISTA:SFI bit are cleared.  
Status Register  
read  
reset value:  
05H  
bit 7  
bit 0  
MFTO MFAB MFAE MFRW MFFE  
STAR  
MAC  
TAC  
PSS  
The status register STAR displays the current state of certain events within the EPIC.  
The STAR register bits do not generate interrupts and are not modified by reading  
STAR.  
The following bit is indirectly used by the signaling handler:  
TAC:  
Timer Active; the timer is running if TAC is set to logical 1, the timer  
is not running if TAC is set to logical 0.  
Note:The timer is only necessary for signaling channels (not C/I) and  
when using a last look period greater or equal to 250 µs.  
Semiconductor Group  
189  
PEB 2055  
PEF 2055  
Application Hints  
Interrupt Status Register  
read  
reset value:  
00H  
bit 7  
bit 0  
ISTA  
TIN  
SFI  
MFFI  
MAC  
PFI  
PIM  
SIN  
SOV  
The ISTA register should be read after an interrupt in order to determine the interrupt  
source.  
In connection with the signaling handler one maskable (MASK) interrupt bit is provided  
by the EPIC in the ISTA register:  
SFI:  
Signaling FIFO Interrupt; This bit is set to logical 1 if there is at least  
one valid entry in the CIFIFO indicating a change in a C/I or SIG  
channel. Reading ISTA does not clear the SFI bit. Instead SFI is  
cleared (logical 0) if the CIFIFO is empty which can be accomplished  
by reading all valid entries of the CIFIFO or by resetting the CIFIFO  
by setting CMDR:CFR to 1.  
Note:The MASK:SFI bit only disables the interrupt pin (INT); the  
ISTA:SFI bit will still be set to logical 1.  
5.5.2.2 Access to Downstream C/I and SIG Channels  
If two consecutive downstream CFI time slots, starting with an even time slot number,  
are programmed as MF and CS channels, the µP can write a 4, 6 or 8 bit wide C/I or SIG  
value to the even addressed downstream CM data field. This value will then be  
transmitted repeatedly in the odd CFI time slot until a new value is loaded.  
This value, first written into MADR, can be transferred to the CM data field using the  
memory operation codes MACR:MOC = 111X or MACR:MOC = 1001 (refer to  
chapter 5.3.3.3).  
The code MACR:MOC = 111X applies if the code field has not yet been initialized with  
a CS channel code. Writing to MACR with MACR:RWS = 0 will then copy the CS channel  
code written to MACR:CMC3 … CMC0 to the CM code field and the value written to  
MADR to the CM data field. The CM address (CFI time slot) is specified by MAAR  
according to figure 48.  
The code MACR:MOC = 1001 applies if the code field has already been properly  
initialized with a CS channel code. In this case only the MADR content will be copied to  
the CM data field addressed by MAAR.  
Semiconductor Group  
190  
PEB 2055  
PEF 2055  
Application Hints  
The value written to MADR should have the following format:  
4 bit C/I value: MADR = 1 1 _ _ _ _ 1 1B  
6 bit SIG value: MADR = _ _ _ _ _ _ 1 1B  
8 bit SIG value: MADR = _ _ _ _ _ _ _ _ B  
Examples  
In CFI mode 0 the downstream time slots 6 and 7 of port 2 shall be initialized as MF and  
CS channels, 6 bit signaling scheme. The initialization value shall be ‘010101’:  
W:MADR = 0101 0111B  
W:MAAR = 0001 1100B  
W:MACR = 0111 1010B  
; SIG value ‘010101’  
; downstream, port 2, time slot 6  
; write CM code + data fields, CM code ‘1010’  
W:MADR = XXXX XXXXB  
W:MAAR = 0001 1101B  
W:MACR = 0111 1011B  
; don’t care  
; downstream, port 2, time slot 7  
; write CM code + data fields, CM code ‘1011’  
The above programming sequence can for example be performed during the  
initialization phase of the EPIC. Once the CFI time slots have been loaded with the  
appropriate codes ('1010' in time slot 6 and ‘1011’ in time slot 7), an access to the  
downstream SIG channel (time slot 7) can be accomplished simply by writing a new  
value to the address of time slot 6:  
W:MADR = 1100 1111B  
W:MAAR = 0001 1100B  
W:MACR = 0100 1000B  
; new SIG value ‘110011’  
; downstream, port 2, time slot 6  
; write CM DF, MOC = 1001  
5.5.2.3 Access to the Upstream C/I and SIG Channels  
If two consecutive upstream CFI time slots, starting with an even time slot number, are  
programmed as MF and CS channels, the µP can read the received 4, 6 or 8 bit C/I or  
SIG values simply by reading the upstream CM data field.  
Two cases can be distinguished:  
When a 4 bit Command/Indication handling scheme is selected, the C/I value received  
in the odd CFI time slot can be read from the even CM address. This value is sampled  
in each frame (every 125 µs). Each change is furthermore indicated by an ISTA:SFI  
interrupt and the address of the corresponding even CM location is stored in the CIFIFO.  
Since the MSB of the CIFIFO is set to 1 for a valid entry (SBV = 1), the value read from  
the CIFIFO can directly be copied to MAAR in order to read the upstream CM data field  
which also requires an MSB set to 1 (U/D = 1).  
When a 6 or 8 bit signaling scheme is selected, the received SIG value is sampled at  
intervals of 125 µs or (TVAL + 1) × 250 µs and stored as the “actual value” at the even  
CM address. The µP can access the actual value simply by reading this even CM data  
field location. Additionally, a “stable value”, based on the double last look algorithm is  
generated: in order to assure that erroneous bit changes at the sampling time point do  
Semiconductor Group  
191  
PEB 2055  
PEF 2055  
Application Hints  
not initiate a definite change, the values of two consecutive sampling points are  
compared with the current old stable value. The stable value is then only updated if both  
new values are identical and differ from the old stored value. The stable value can be  
read from the odd CM data field location. Each change in the stable value is furthermore  
indicated by an ISTA:SFI interrupt and the address of the corresponding odd CM  
location is stored in the CIFIFO. Since the MSB of the CIFIFO is set to 1 for a valid entry  
(SBV = 1), the value read from the CIFIFO can directly be copied to MAAR in order to  
read the upstream CM data field, which also requires an MSB set to 1 (U/D = 1).  
Note: The sampling interval is selected in the TIMR register (refer to chapter 5.5.2.1).  
If the sampling interval is set to 125 µs (TIMR:SSR = 1), it is not necessary to start  
the timer to operate the change detection logic. If, however, the last look period is  
determined by TIMR:TVAL6 … 0 (TIMR:SSR = 0) it is required to start the timer  
(CMDR:ST = 1) to operate the change detection logic and to generate SFI  
interrupts.  
Examples  
In CFI mode 0 the upstream time slots 6 and 7 of port 2 shall be initialized as MF and  
CS channels, 6 bit signaling scheme, the expected value from the codec after power up  
shall be “011101”:  
W:MADR = 0111 0111B  
W:MAAR = 1001 1100B  
W:MACR = 0111 1010B  
; expected actual value “011101”  
; upstream, port 2, time slot 6  
; write CM code + data fields, CM code “1010”  
W:MADR = 0111 0111B  
W:MAAR = 1001 1101B  
W:MACR = 0111 1010B  
; expected stable value “011101”  
; upstream, port 2, time slot 7  
; write CM code + data fields, CM code “1010”  
The above programming sequence can for example be performed during the  
initialization phase of the EPIC. At this stage the CFI is not operational (OMDR = 80H),  
i.e. the values received at the CFI are ignored.  
Semiconductor Group  
192  
PEB 2055  
PEF 2055  
Application Hints  
If the expected value “011101” is actually received upon activation of the CFI (e.g.  
OMDR = EEH), no interrupt will be generated at this moment. But the change detection  
is now enabled and each valid change in the received SIG value (e.g. new value  
“001100”) will generate an interrupt, with the address being stored in the CIFIFO. The  
reaction of the µP to such an event would then look like this:  
R:ISTA  
= 0100 0000B  
; SFI interrupt  
R:CIFIFO = 1001 1101B  
W:MAAR = 1001 1101B  
W:MACR = 1100 1000B  
wait for STAR:MAC = 0  
; address of upstream, port 2, time slot 7  
; copy the address from CIFIFO to MAAR  
; read back command for CM DF, MOC = 1001  
R:MADR = 0011 00XXB  
; read new SIG value (e.g. 001100)  
wait for further ISTA:SFI interrupts  
5.5.3  
Monitor/Feature Control (MF) Handler  
If the configurable interface CFI of the EPIC is configured as IOM or SLD interface, it is  
necessary to communicate with the connected subscriber circuits such as layer-1  
transceivers (ISDN line cards) or codec filter devices (analog line cards) over the monitor  
channel (IOM) or feature control channel (SLD). In order to simplify this task the EPIC  
has implemented the Monitor/Feature Control (MF) Handler which autonomously  
controls and supervises the data transfer via these channels.  
The communication protocol used in an MF channel is interface and subscriber circuit  
specific.  
Three cases can be distinguished:  
IOM®-2 Interface Protocol  
In this case the monitor channel protocol is a handshake procedure used for high speed  
information exchange between the EPIC and other devices such as the IEC-Q  
(PEB 2091), SBCX (PEB 2081) or SICOFI2 (PEB 2260).  
The monitor channel operates on an asynchronous basis. While data transfers on the  
IOM-2 interface take place synchronized to the IOM frame, the flow of data is controlled  
by a handshake procedure based on the monitor channel receive (MR) and the monitor  
channel transmit (MX) bits located at the end of the fourth time slot of the respective  
IOM-2 channel.  
For the transmission of a data byte for example, the data is placed onto the downstream  
monitor channel and the MX bit is activated. This byte will then be transmitted repeatedly  
once per 8 kHz frame until the receiver acknowledges the transfer via the upstream MR  
bit.  
A detailed description of the IOM-2 monitor channel operation can be found in the  
“IOM-2 Interface Reference Guide”.  
Semiconductor Group  
193  
PEB 2055  
PEF 2055  
Application Hints  
IOM®-1 Interface Protocol  
In this case the monitor channel protocol is a non handshake procedure which can be  
used to exchange one byte of information at a time between the EPIC and a layer-1  
device such as the IBC (PEB 2095) or the IEC-T (PEB 2090).  
Data bytes to be transmitted are sent once in the downstream monitor channel. Since  
the monitor channel is idle (FFH) when no data is being transmitted, the receiving device  
accepts only valid data bytes which are different from FFH. If a message shall be sent  
back to the EPIC, this must occur in the frame following the frame of reception.  
SLD Interface Protocol  
The transfer of control information over the feature control channel of an SLD interface  
e.g. for programming the coefficients to a SICOFI (PEB 2060) device is also performed  
without a handshake procedure. Data is transmitted and received synchronous to the  
8 kHz frame at a speed of one data byte per frame.  
The MF handler of the EPIC supports all three kinds of protocols. A bidirectional 16 byte  
FIFO, the MFFIFO, serves as data buffer for outgoing and incoming MF messages in all  
protocol modes. This implies that the MF communication is always performed on a  
half-duplex basis.  
Differentiation between IOM-2 and IOM-1/SLD modes is made via the MF Protocol  
Selection bit MFPS in the Operation Mode Register OMDR.  
Since the IOM-1 and SLD protocols are very similar, they are treated by the EPIC in  
exactly the same way i.e. without handshake protocol. The only processing difference  
concerns the involved upstream time slot when receiving data:  
When configured as IOM interface (CFI modes 0, 1 or 2), the CFI ports consist of  
separate upstream (DU) and downstream (DD) lines. In this case MF data is transmitted  
on DD and received on DU of the same CFI time slot.  
When configured as SLD interface (CFI mode 3), the CFI ports consist of bidirectional  
lines (SIP). The first four time slots of the frame are used as downstream time slots and  
the last four as upstream time slots. In this case the MF data is transmitted in the  
downstream feature control time slot and received on the same CFI line but four time  
slots later in the upstream feature control time slot.  
CFI time slots which should be processed by the MF handler must first be initialized as  
MF/CS channels with appropriate codes in the Control Memory Code Field (refer to  
chapter 5.5.1).  
Except for broadcast operation, communication over the MF channel is only possible  
with one subscriber circuit at a time. The MF handler must therefore be pointed to that  
particular time slot via the address register MFSAR.  
Normally MF channel transfers are initiated by the EPIC (master). The subscriber circuits  
(slaves) will only send back monitor messages upon a request from the master device.  
Semiconductor Group  
194  
PEB 2055  
PEF 2055  
Application Hints  
In IOM-2 applications, however, (active handshake protocol), it is also possible that a  
slave device requests a data transfer e.g. when an IEC-Q device has received an EOC  
message over the U interface.  
For these applications the EPIC has implemented a search mechanism that looks for  
active handshake bits. When such a monitor channel is found, the µP is interrupted  
(ISTA:MAC) and the address of the involved MF channel is stored in a register (MFAIR).  
The MF handler can then be pointed to that channel by copying the contents of MFAIR  
to MFSAR and the actual message transfer can take place.  
5.5.3.1 Registers used in Conjunction with the MF Handler  
In detail, the following registers are involved when performing MF channel transfers:  
Operation Mode Register  
read/write  
reset value:  
00H  
bit 7  
bit 0  
RBS  
OMDR:  
OMS1 OMS0  
PSB  
PTL  
COS  
MFPS  
CSB  
MFPS:  
MF channel Protocol Selection;  
MFPS = 0: Handshake facility disabled; to be used for SLD and  
IOM-1 applications.  
MFPS = 1: Handshake facility enabled; to be used for IOM-2  
applications.  
Monitor/Feature Control Channel FIFO read/write reset value:  
empty  
bit 7  
bit 0  
MFD1 MFD0  
MFFIFO: MFD7  
MFD6  
MFD5  
MFD4  
MFD3  
MFD2  
The 16 byte bidirectional MFFIFO provides intermediate storage for data bytes to be  
transmitted or received over the monitor or feature control channel.  
Note: The data transfer over an MF channel is half-duplex i.e. if a “transmit + receive”  
command is issued, the transmit section of the transfer must first be completed  
before the receive section starts.  
MFD7 … 0:  
MF Data bits 7 … 0; MFD7 (MSB) is the first bit to be sent over the  
serial CFI, MFD0 (LSB) the last.  
Semiconductor Group  
195  
PEB 2055  
PEF 2055  
Application Hints  
MF Channel Subscriber Address Register  
write reset value:  
undefined  
bit 7  
bit 0  
MFSAR: MFTC1 MFTC0 SAD5  
SAD4  
SAD3  
SAD2  
SAD1  
SAD0  
The exchange of monitor data normally takes place with only one subscriber circuit at a  
time. This register serves to point the MF handler to that particular CFI time slot.  
MFTC1 … 0:  
MF Channel Transfer Control 1 … 0; these bits, in addition to  
CMDR:MFT1,0 and OMDR:MFPS control the MF channel transfer as  
indicated in table 32.  
SAD5 … 0:  
Subscriber address 5 … 0; these bits define the addressed  
subscriber. The CFI time slot encoding is similar to the one used for  
Control Memory accesses using the MAAR register (see figure 48).  
CFI time slot encoding of MFSAR derived from MAAR:  
MAAR: MA7  
MA6  
MA5  
MA4  
MA3  
MA2  
MA1  
MA0  
MFSAR: MFTC1 MFTC0 SAD5 SAD4 SAD3 SAD2 SAD1 SAD0  
MAAR:MA7 selects between upstream and downstream CM blocks. This information is  
not required since the transfer direction is defined by CMDR (transmit or receive).  
MAAR:MA0 selects between even and odd time slots. This information is also not  
required since MF channels are always located on even time slots.  
Semiconductor Group  
196  
PEB 2055  
PEF 2055  
Application Hints  
Example  
In CFI mode 0, IOM channel 5 (time slot 16 … 19) of port 2 shall be addressed for a  
transmit monitor transfer:  
MFSAR = 0010 0110B; the monitor channel occupies time slot 18 (10010B) of port 2  
(10B)  
MF Channel Active Indication Register  
read reset value:  
undefined  
bit 0  
bit 7  
MFAIR:  
0
SO  
SAD5  
SAD4  
SAD3  
SAD2  
SAD1  
SAD0  
This register is only used in IOM-2 applications (active handshake protocol) in order to  
identify active monitor channels when the ‘Search for active monitor channels’ command  
(CMDR:MFSO) has been executed.  
SO:  
MF Channel Search On; this bit indicates whether the EPIC is still  
busy looking for an active channel (1) or not (0).  
SAD5 … 0:  
Subscriber Address 5 … 0; after an ISTA:MAC interrupt these bits  
point to the port and time slot where an active channel has been  
found. The coding is identical to MFSAR:SAD5 … SAD0. The  
contents of MFAIR can directly be copied to MFSAR in order to point  
the MF handler to the channel which requests a monitor receive  
operation.  
Command Register  
read  
reset value:  
00H  
bit 7  
bit 0  
MFT0 MFSO MFFR  
CMDR  
0
ST  
TIG  
CFR  
MFT1  
Writing to CMDR starts the respective monitor channel operation.  
MFT1 … 0:  
MF Channel Transfer Control Bits 1, 0; these bits start the monitor  
transfer enabling the contents of the MFFIFO to be exchanged with  
the subscriber circuits as specified in MFSAR. The function of some  
commands depends furthermore on the selected protocol  
(OMDR:MFPS). Table 32 summarizes all available MF commands.  
MFSO:  
MF Channel Search On; if set to 1, the EPIC starts to search for active  
MF channels. Active channels are characterized by an active MX bit  
(logical 0) sent by the remote transmitter. If such a channel is found,  
Semiconductor Group  
197  
PEB 2055  
PEF 2055  
Application Hints  
the corresponding address is stored in MFAIR and an ISTA:MAC  
interrupt is generated. The search is stopped when an active MF  
channel has been found or when OMDR:OMS0 is set to 0.  
MFFR:  
MFFIFO Reset; setting this bit resets the MFFIFO and all operations  
associated with the MF handler (except for the search function) within  
2 RCL periods. The MFFIFO is set into the state ‘MFFIFO empty,  
write access enabled’ and any monitor data transfer currently in  
process will be aborted. MFFR should be set when all data bytes have  
been read from the MFFIFO after a monitor receive operation.  
Table 32  
Transfer Mode  
CMDR:  
MFT, MFT0  
MFSAR  
Protocol  
Selection  
Application  
Inactive  
00  
01  
01  
XXXXXXXX  
HS, no HS1) idle state  
Transmit  
00 SAD5 … 0 HS, no HS1) IOM-2, IOM-1, SLD  
Transmit  
01XXXXXX  
HS, no HS1) IOM-2, IOM-1, SLD  
Broadcast  
Test Operation  
01  
11  
10 - - - - - -  
00 SAD5 … 0 HS2)  
HS, no HS1) IOM-2, IOM-1, SLD  
Transmit  
IOM-2  
Continuous  
Transmit + Receive  
Same Time Slot  
Any # of Bytes  
1 byte expected  
2 bytes expected  
8 bytes expected  
10  
10  
10  
10  
00 SAD5 … 0 HS2)  
IOM-2  
IOM-1  
(IOM-1)  
(IOM-1)  
(IOM-1)  
00 SAD5 … 0 no HS1)  
01 SAD5 … 0 no HS1)  
10 SAD5 … 0 no HS1)  
11 SAD5 … 0 no HS1)  
16 bytes expected 10  
Transmit + Receive  
Same Line  
1 byte expected  
2 bytes expected  
8 bytes expected  
11  
11  
11  
00 SAD5 … 0 no HS1)  
01 SAD5 … 0 no HS1)  
10 SAD5 … 0 no HS1)  
11 SAD5 … 0 no HS1)  
SLD  
SLD  
SLD  
SLD  
16 bytes expected 11  
1)  
Handshake facility disabled (OMDR:MFPS = 0)  
Handshake facility enabled (OMDR:MFPS = 1)  
2)  
Semiconductor Group  
198  
PEB 2055  
PEF 2055  
Application Hints  
Status Register  
read  
reset value:  
00H  
bit 7  
bit 0  
STAR  
MAC  
TAC  
PSS  
MFTO MFAB MFAE MFRW MFFE  
The status register STAR displays the current state of the MFFIFO and of the monitor  
transfer operation. It should be interrogated after an ISTA:MFFI interrupt and prior to  
accessing the MFFIFO.  
The STAR register bits do not generate interrupts and are not modified by reading  
STAR.  
MFTO:  
MFAB:  
MFAE:  
MFRW:  
MFFE:  
MF Channel Transfer in Operation; an MF channel transfer is in  
operation (1) or not (0).  
MF Channel Transfer Aborted; a logical 1 indicates that the remote  
receiver aborted a handshaked message transfer.  
MFFIFO Access Enable; the MFFIFO may be either read or written to  
(1) or it may not be accessed (0).  
MFFIFO Read/Write; if MFAE is set to logical 1 the MFFIFO may be  
read (1) or is ready to be written to (0).  
MFFIFO Empty; the MFFIFO is empty (1) or not empty (1).  
Interrupt Status Register  
read  
reset value:  
00H  
bit 7  
bit 0  
SOV  
ISTA  
TIN  
SFI  
MFFI  
MAC  
PFI  
PIM  
SIN  
The ISTA register should be read after an interrupt in order to determine the interrupt  
source. In connection with the monitor handler two maskable (MASK) interrupt bits are  
provided by the EPIC:  
MFFI:  
MFFIFO interrupt; if this bit is set to 1, the last MF channel command  
(issued by CMDR:MFT1, MFT0) has been executed and the EPIC is  
ready to accept the next command. Additional information can be  
read from STAR:MFTO … MFFE. MFFI is reset by reading ISTA.  
MAC:  
Monitor Channel Active Interrupt; this bit set to 1 indicates that the  
EPIC has found an active monitor channel. A new search can be  
started by reissuing the CMDR:MFSO command. MAC is reset by  
reading ISTA.  
Semiconductor Group  
199  
PEB 2055  
PEF 2055  
Application Hints  
5.5.3.2 Description of the MF Channel Commands  
Transmit Command  
The transmit command can be used for sending MF data to a single subscriber circuit  
when no answer is expected. It is applicable for both handshake and non handshake  
protocols. The message (up to 16 bytes) can be written to the MFFIFO after interrogation  
of the STAR register. After writing of the MF channel address to MFSAR the transfer can  
be started using the transmit command (CMDR = 04H). The contents of the MFFIFO will  
then be transmitted byte by byte to the subscriber circuit.  
If the handshake facility is disabled (IOM-1/SLD), the data is sent at a speed of one byte  
per frame.  
If the handshake facility is enabled (IOM-2), each data byte must be acknowledged by  
the subscriber circuit before the next one is sent. The transfer speed depends therefore  
on the reaction time of the subscriber circuit. The EPIC can transmit a message at a  
maximum speed of one byte per two frames.  
In order to avoid blocking the software when a subscriber circuit fails to acknowledge a  
message, a software time out, which resets the monitor transfer (CMDR = 01H) should  
be implemented.  
If the remote partner aborts the reception of an arriving message i.e. if the EPIC detects  
an inactive MR bit during at least two consecutive frames, the transmit operation will be  
stopped, the ISTA:MFFI interrupt will be generated and the STAR:MFAB bit will be set  
to 1. The CMDR:MFFR bit should then be set to clear the MFAB bit before the next  
transfer.  
When all data bytes of the MFFIFO have been sent (and eventually acknowledged) the  
EPIC generates an ISTA:MFFI interrupt indicating the end of the transfer. The MF  
handler may then be pointed to another subscriber address for another monitor transfer.  
Semiconductor Group  
200  
PEB 2055  
PEF 2055  
Application Hints  
R
µP  
EPIC  
MFFR  
W : CMDR = 01  
R : STAR = 05  
MFFIFO Reset  
MFAE, MFFE  
MFFIFO Empty  
Write Access Enabled  
1
2
N
W : MFFIFO = Data  
R : STAR = 04  
MFFIFO not Empty  
Write Access Enabled  
MFTC1, 0 = 00  
MFT1, 0 = 01  
W : MFSAR = Address  
Da 1  
Ack 1  
Da 2  
Ack 2  
Da N  
Ack N  
W : CMDR = 04  
R : STAR = 12  
MFFIFO not Empty  
Access Disabled  
Transfer in Operation  
MFTO, MFRW, MFFE  
MFFI Interrupt  
R : STAR = 13  
MFFIFO Empty  
Access Disabled  
Transfer in Operation  
MR = 0  
MR = 1  
R : ISTA = 20  
R : STAR = 05  
MFFIFO Empty  
Write Access Enabled  
Transfer Completed  
ITD08085  
Figure 69  
Flow Diagram “Transmit Command”  
Transmit Continuous Command  
The transmit continuous command can be used in IOM-2 applications only (active  
handshake protocol) to send monitor messages longer than 16 bytes to a single  
subscriber circuit.  
When this command is given, the EPIC transmits the contents of the MFFIFO as with the  
normal transmit command but does not conclude the transfer by setting MX inactive  
when the MFFIFO is empty. Instead, the µP is interrupted (ISTA:MFFI) and requested to  
write a new block of data into the MFFIFO. This block may then again be transmitted  
using the transmit continuous command or, if it is the last block of the long message, it  
may be transmitted using the normal transmit command (CMDR:MFT1, MFT0 = 01). If  
an answer is expected from the subscriber circuit, the last block may also be terminated  
using the transmit + receive command (CMDR:MFT1, MFT0 = 10). Each message block  
may be of arbitrary length (1 to 16 bytes).  
Semiconductor Group  
201  
PEB 2055  
PEF 2055  
Application Hints  
R
µP  
EPIC  
MFFR  
W : CMDR = 01  
R : STAR = 05  
MFFIFO Reset  
MFAE, MFFE  
MFFIFO Empty  
Write Access Enabled  
1
2
W : MFFIFO = Data  
R : STAR = 04  
16  
MFFIFO not Empty  
Write Access Enabled  
MFTC1, 0 = 00  
MFT1, 0 = 11  
W : MFSAR = Address  
Da 1  
Ack 1  
Da 2  
Ack 2  
Da 16  
Ack 16  
W : CMDR = 0C  
R : STAR = 12  
MFFIFO not Empty  
Access Disabled  
Transmit Transfer  
in Operation  
MFFI Interrupt  
R : ISTA = 20  
R : STAR = 15  
MFFIFO Empty  
Write Access Enabled  
Transfer in Operation  
MX = 0  
17  
18  
N
W : MFFIFO = Data  
R : STAR = 14  
MX = 0  
MFFIFO not Empty  
Write Access Enabled  
Transfer in Operation  
MFT1, 0 = 01  
Da 17  
Ack 17  
Da 18  
Ack 18  
Da N  
W : CMDR = 04  
R : STAR = 12  
MFFIFO not Empty  
Access Disabled  
Transmit Transfer  
in Operation  
MFTO, MFRW, MFFE  
MFFI Interrupt  
Ack N  
R : STAR = 13  
MFFIFO Empty  
Access Disabled  
Transfer in Operation  
MR = 0  
MR = 1  
R : ISTA = 20  
R : STAR = 05  
MFFIFO Empty  
Write Access Enabled  
Transfer Completed  
ITD08086  
Figure 70  
Flow Diagram “Transmit Continuous Command”  
Transmit + Receive Same Time Slot Command  
The transmit + receive same time slot command can be used to send a message to a  
subscriber circuit, which will respond with an answer, e.g. reading back the coefficients  
of a SICOFI device. After first transmitting the contents of the MFFIFO (as with the  
normal transmit command), the MFFIFO is ready to accept an incoming message which  
can then be read by the µP when the transfer is completed.  
Semiconductor Group  
202  
PEB 2055  
PEF 2055  
Application Hints  
This command can also be used to perform a receive only operation: if a message shall  
be received without transmission (e.g. after an active monitor channel has been found)  
the transmit + receive command is issued with an empty MFFIFO.  
The command is applicable for both handshake and non-handshake protocols. Since the  
transfer operation is performed on the same time slot, its use is intended for IOM  
applications:  
– IOM-2, handshake facility enabled:  
The contents of the MFFIFO is sent to the subscriber circuit subject to the IOM-2 protocol  
i.e each byte must be acknowledged before the next one is sent. When the MFFIFO is  
empty, the EPIC starts to receive the incoming data bytes, each byte being  
autonomously acknowledged by the EPIC. Up to 16 bytes may be stored in the MFFIFO.  
When the end of message is detected (MX bit inactive during two consecutive frames),  
the transfer is considered terminated and an ISTA:MFFI interrupt is generated. The µP  
can then fetch the message from the MFFIFO. In order to determine the length of the  
arrived message, the STAR:MFFE bit (MFFIFO Empty) should be evaluated before each  
read access to the MFFIFO. After all bytes have been read, the MFFIFO must be reset  
with the CMDR:MFFR command in order to enable new monitor transfer operations.  
Semiconductor Group  
203  
PEB 2055  
PEF 2055  
Application Hints  
R
µP  
EPIC  
MFFR  
W : CMDR = 01  
R : STAR = 05  
MFFIFO Reset  
MFAE, MFFE  
MFFIFO Empty  
Write Access Enabled  
1
2
N
W : MFFIFO = Data  
R : STAR = 04  
MFFIFO not Empty  
Write Access Enabled  
MFTC1, 0 = 00  
MFT1, 0 = 10  
W : MFSAR = Address  
Da 1  
Ack 1  
Da 2  
Ack 2  
Da N  
Ack N  
W : CMDR = 08  
R : STAR = 12  
MFFIFO not Empty  
Access Disabled  
Transmit Transfer  
in Operation  
MFTO, MFRW,MFFE  
MFFE  
R : STAR = 13  
R : STAR = 01  
MFFIFO Empty  
Access Disabled  
Transfer in Operation  
MR = 0  
MR = 1  
MFFIFO Empty  
Access Disabled  
No Transfer in Operation  
MFTO  
Da 1  
Ack 1  
Da 2  
Ack 2  
Da M  
Ack M  
MFFIFO not Empty  
Access Disabled  
Receive Transfer  
in Operation  
R : STAR = 10  
MFFI Interrupt  
1
R : ISTA = 20  
R : STAR = 06  
R : MFFIFO = Data  
MFFIFO not Empty  
Read Access Enabled  
Transfer Completed  
2
M
MFAE, MFRW, MFFE  
R : STAR = 07  
MFFIFO Empty  
Read Access Enabled  
ITD08087  
Figure 71  
Flow Diagram “Transmit + Receive Same Time Slot Command”  
The reception of monitor messages may also (if required) be aborted at any time simply  
by setting the CMDR:MFFR bit while the receive transfer is still in operation.  
If more than 16 bytes shall be received, the following procedure can be adopted:  
The first 16 data bytes received will be stored in the MFFIFO and acknowledged to the  
remote partner. The presence of a 17th byte on the receive line will lead to an ISTA:MFFI  
interrupt. While the transfer is still in operation (STAR = 16H), with the 17th byte still left  
unacknowledged, the µP can read the first 16 bytes out of the MFFIFO. When this is  
Semiconductor Group  
204  
PEB 2055  
PEF 2055  
Application Hints  
done (STAR = 17H), the µP issues again (with an empty MFFIFO) the transmit + receive  
command (CMDR = 08H) and the EPIC is again ready to receive and acknowledge  
further monitor bytes.  
– IOM-1, handshake facility disabled  
The contents of the MFFIFO are sent to the subscriber circuit at a speed of 1 byte per  
frame. When the last byte has been transmitted, the EPIC stores the received monitor  
bytes of the next subsequent frames into the MFFIFO. The receive transfer is completed  
and an ISTA:MFFI interrupt is generated after either 1, 2, 8, or 16 frames. The actual  
number of stored bytes can be selected with MFSAR:MFTC1,MFTC0.  
Transmit + Receive Same Line Command  
This command is similar to the Transmit + Receive same time slot command i.e. it can  
be used to send a message to a subscriber circuit which will respond with an answer. Its  
use is, however, intended for SLD applications: CFI mode 3, 8 time slots/frame,  
handshake facility disabled.  
The transmit operation is performed in the downstream time slot specified in MFSAR  
while the receive operation is performed on the same SIP line, but four time slots later  
in the upstream time slot.  
Transmit Broadcast Command  
The Transmit Broadcast Command can be used for sending a monitor/feature control  
message to all subscriber circuits simultaneously. It is applicable for both handshake  
and non handshake protocols. The procedure is similar to the normal transmit command  
with the exception that the contents of the MFFIFO is transmitted on all downstream MF  
time slots (defined by the CM code field). If the handshake protocols is active (IOM-2)  
the data bytes are transmitted at a speed of one byte per three frames and the arriving  
acknowledgments are ignored.  
Test Operation Command  
When executing the Test Operation Command, a message written to the MFFIFO will  
not be transmitted to the subscriber circuit but may instantaneously be read back. All  
interrupts (ISTA) and status (STAR) bits will be generated in the same manner as for a  
normal transmit + receive transfers. It is applicable for both handshake and  
non-handshake protocols.  
Semiconductor Group  
205  
PEB 2055  
PEF 2055  
Application Hints  
Search For Active Monitor Channels Command  
In IOM-2 applications the monitor channel is sometimes used for low speed data  
transfers over the S and Q channels of an S interface or over the EOC channel of a U  
(2B1Q) interface. The layer-1 transceivers (SBCX PEB 2081, IEC-Q PEB 2091) may  
then, upon reception of a new message, start a monitor channel communication with the  
EPIC.  
For those applications where a slave device initiates an MF channel transfer, the EPIC  
has implemented the “Search For Active Monitor Channels Command”.  
The active handshake protocol (OMDR:MFPS = 1) must be selected for this function.  
When the “MF Search On” command (CMDR:MFSO = 1) is executed, the EPIC  
searches for active handshake bits (MX) on all upstream monitor channels. As soon as  
an active channel is found, an ISTA:MAC interrupt is generated, the search is stopped,  
and the address of this channel is stored in MFAIR. The µP can then copy the value of  
MFAIR to MFSAR in order to point the MF handler to that particular channel. With an  
empty MFFIFO the transmit + receive same time slot command can be executed to  
initiate the reception of the monitor message. The EPIC will then autonomously  
acknowledge each received byte and report the end of the transfer by an ISTA:MFFI  
interrupt. The µP can read the message from the MFFIFO and, if required, execute a  
new MF Search command.  
Note: The search should only be started when no receive transfer is in operation,  
otherwise each received byte will lead to the ISTA:MAC interrupt.  
Once started, the search for active monitor channels can only be stopped when such a  
channel has been found or when the Control Memory is reset or initialized  
(OMDR:OMS0 = 0).  
Semiconductor Group  
206  
PEB 2055  
PEF 2055  
Application Hints  
R
µP  
W : CMDR = 02  
EPIC  
MFSO  
Search for Active  
R : MFAIR = 01XXXXXX  
Monitor Channels is On  
Da 1  
MAC Interrupt  
R : ISTA = 10  
Channel Found  
Search is Off  
R : MFAIR = 00 SAD5...0  
W : MFSAR = MFAIR  
R : STAR = 05  
MFFIFO Empty  
Write Access Enabled  
MFT1, 0 = 10  
Ack 1  
Da 2  
Ack 2  
Da M  
Ack M  
MFFIFO Empty  
Access Disabled  
Receive Transfer  
in Operation  
W : CMDR = 08  
R : STAR = 10  
MFFI Interrupt  
1
R : ISTA = 20  
R : STAR = 06  
W : MFFIFO = Data  
MFFIFO not Empty  
Read Access Enabled  
Transfer Completed  
2
M
MFAE, MFRW, MFFE  
MFFIFO Empty  
R : STAR = 07  
Read Access Enabled  
ITD08088  
Figure 72  
Flow Diagram “Search For Active Monitor Channels Command”  
Semiconductor Group  
207  
PEB 2055  
PEF 2055  
Application Hints  
5.6  
µP Channels  
If a CFI time slot shall be accessed by the µP instead of being switched to the PCM  
interface, this channel can be configured as a µP channel. This is achieved by writing  
the code ‘1001’ to the CM code field. In this case the content of the corresponding CFI  
time slot is directly exchanged with the CM data field. Figure 73 and figure 74 illustrate  
the use of the Control Memory (CM) data and code fields for such applications.  
If a CFI time slot is initialized as µP channel, the function taken on by the CM data field  
can be compared to the function taken on by the Data Memory (DM) data field at the  
PCM interface, i.e. it buffers the PCM data received or to be transmitted at the serial  
interface. In contrast to the PCM interface, where PCM idle channels can be  
programmed on a 2 bit subtime slot basis, the CFI only allows µP access for full 8 bit  
time slots.  
Control Memory  
CFI  
Frame  
Code Field  
Data Field  
0
Down-  
stream  
1
0
0
1
127  
MACR:  
0
1
0
0
1
0
0
0
MADR:  
MAAR:  
0
MA6  
.
.
.
.
.
MA0  
ITD08089  
Figure 73  
µP Access to the Downstream CFI Frame  
Semiconductor Group  
208  
 
 
PEB 2055  
PEF 2055  
Application Hints  
Control Memory  
CFI  
Frame  
Code Field  
Data Field  
0
Up-  
1
0
0
1
stream  
127  
MACR:  
1
1
0
0
1
0
0
0
MADR:  
MAAR:  
1
MA6  
.
.
.
.
.
MA0  
ITD08090  
Figure 74  
µP Access to the Upstream CFI Frame  
The value written to the downstream CM data field location is transmitted repeatedly in  
every frame (CFI idle value) during the corresponding downstream CFI time slot until a  
new value is loaded or the ‘µP channel’ function is disabled. There are no interrupts  
generated.  
The upstream CM data field can be read at any time. The CM data field is updated in  
every frame. The last value read represents the value received. There are no interrupts  
generated.  
For frame-synchronous exchange of data between the µP and the CFI, the synchronous  
transfer utility must be used (refer to chapter 5.7). Since this utility realizes the data  
exchange between the STDA (STDB) register and the CM data field, it is also necessary  
to initialize the corresponding CFI time slots as µP channels.  
The following sequences can be used to program, verify, and cancel a CFI µP channel:  
Semiconductor Group  
209  
PEB 2055  
PEF 2055  
Application Hints  
Writing a Downstream CFI Idle Value  
– in case the CM code field has not yet been initialized with the ‘µP channel’ code:  
W:MADR  
W:MAAR  
W:MACR  
= CFI idle value to be transmitted  
= downstream CFI port and time slot encoded according to figure 48  
= 0111 1001B = 79H ; CM code ‘1001’ (µP transfer)  
– in case the CM code field has already been initialized with the ‘µP channel’ code:  
W:MADR  
W:MAAR  
W:MACR  
= CFI idle value to be transmitted  
= downstream CFI port and time slot encoded according to figure 48  
= 0100 1000B = 48H; MOC code ‘1001’ (CM data field access)  
Reading an Upstream CFI idle Value  
– Initializing an upstream CFI time slot as a µP channel:  
W:MADR  
W:MAAR  
W:MACR  
= don’t care  
= upstream CFI port and time slot encoded according to figure 48  
= 0111 1001B = 79H; CM code ‘1001’ (µP transfer)  
– Reading the upstream CFI idle value:  
W:MAAR  
W:MACR  
= upstream CFI port and time slot encoded according to figure 48  
= 1100 1000B = C8H; MOC code ‘1001’ (CM data field access)  
wait for STAR:MAC = 0  
R:MADR  
= received CFI idle value  
Reading Back the Idle Value Transmitted at a Downstream CFI µP Channel:  
W:MAAR  
W:MACR  
= downstream CFI port and time slot encoded according to figure 48  
= 1100 1000B = C8H; MOC code ‘1001’ (CM data field access)  
wait for STAR:MAC = 0  
R:MADR  
= transmitted CFI idle value  
Reading Back the CFI Functionality of a given CFI Time Slot:  
W:MAAR  
W:MACR  
= CFI port and time slot encoded according to figure 48  
= 1111 0000B = F0H; MOC code ‘111X’ (CM code field access)  
wait for STAR:MAC = 0  
R:MADR  
= XXXX codeB; if code = 1001, the CFI time slot is a ‘µP channel’  
Cancelling of a Programmed CFI µP Channel:  
W:MADR  
W:MAAR  
W:MACR  
= don’t care  
= CFI port and time slot encoded according to figure 48  
= 0111 0000B = 70H; code ‘0000’ (unassigned channel)  
Semiconductor Group  
210  
PEB 2055  
PEF 2055  
Application Hints  
Examples  
In CFI mode 1 the following µP channels shall be realized:  
Upstream: CFI port 1, time slot 7:  
W:MADR = 1111 1111B  
W:MAAR = 1000 1111B  
W:MACR = 0111 1001B  
; don’t care  
; CFI time slot encoding according to figure 48  
; CM code for a µP channel (code ‘1001’)  
Downstream: CFI port 0, time slot 2, the value ‘0000 0111’ shall be transmitted:  
W:MADR = 0000 0111B  
W:MAAR = 0000 0100B  
W:MACR = 0111 1001B  
; CFI idle value ‘0000 0111’  
; CFI time slot encoding according to figure 48  
; CM code for a µP channel (code ‘1001’)  
The next sequence will read the currently received value at DU1, TS7:  
W:MAAR = 1000 1111B ; upstream CFI port and time slot  
W:MACR = 1100 1000B = C8H; read back command  
wait for STAR:MAC = 0  
R:MADR = value  
; received CFI idle value  
Semiconductor Group  
211  
PEB 2055  
PEF 2055  
Application Hints  
5.7  
Synchronous Transfer Utility  
The synchronous transfer utility allows the synchronous exchange of information  
between the PCM interface, the configurable interface, and the µP interface for two  
independent channels (A and B). The µP can thus monitor, insert, or manipulate the data  
synchronously to the frame repetition rate. The synchronous transfer is controlled by the  
synchronous transfer registers.  
The information is buffered in the synchronous transfer data register STDA (STDB). It is  
copied to STDA (STDB) from a data or control memory location pointed to by the content  
of the synchronous receive register SARA (SARB) and copied from the STDA (STDB)  
to a data or control memory location pointed to by the content of the synchronous  
transfer transmit register SAXA (SAXB).  
The SAXA (SAXB) and SARA (SARB) registers identify the interface (PCM or CFI) as  
well as the time slot and port numbers of the involved channels according to figure 48.  
Control bits in the synchronous transfer control register STCR allow restricting the  
synchronous transfer to one of the possible subtime slots and enables or disables the  
synchronous transfer utility.  
For example, it is possible to read information via the downstream data memory from the  
PCM interface input to the STDA (STDB) register and to transmit it from this register  
back via the upstream data memory to the PCM interface output, thus establishing a  
PCM - PCM loop. Similarly the synchronous transfer facility may be used to loop back  
configurable interface channels or to establish connections between the CFI and PCM  
interfaces. While the information is stored in the data register STDA (STDB), it may be  
read and or modified by the µP.  
Semiconductor Group  
212  
PEB 2055  
PEF 2055  
Application Hints  
Control Memory  
Code Field Data Field  
Data Memory  
CFI  
Frame  
PCM  
Frame  
Data Field  
0
0
1
0 0 1  
2
3
Up-  
Up-  
stream  
stream  
127  
127  
0
0
1
4
Down-  
Down-  
stream  
stream  
1
0 0 1  
127  
127  
STDA/STDB:  
1
2
SAXA/SAXB:  
SARA/SARB:  
1
1
CFI Port + Time - Slot  
CFI Port + Time - Slot  
3
4
SAXA/SAXB:  
SARA/SARB:  
0
0
PCM Port + Time - Slot  
PCM Port + Time - Slot  
ITD08091  
Figure 75  
Access to PCM and CFI Data Using the Synchronous Transfer Utility  
In upstream transmit direction (PCM interface output), it is necessary to assure that no  
other data memory access writes to the same location in the upstream DM block. Hence  
an upstream connection involving the same PCM port and time slot as the synchronous  
transfer may not be programmed.  
An idle code previously written to the data or control memory for the upstream or  
downstream directions is overwritten.  
At the PCM interface it is possible to restrict the synchronous exchange with the data  
registers STDA (STDB) to a 2 or 4 bit subtime slot position. The working principle is  
similar to the subchannel switching described in chapter 5.4.2.  
Semiconductor Group  
213  
PEB 2055  
PEF 2055  
Application Hints  
If the CFI is selected as source/destination of the synchronous transfer, the contents of  
the data register STDA (STDB) are exchanged with the control memory data field. It is  
therefore necessary to initialize the corresponding control memory code field as  
µP channel’ (code ‘1001’). Also refer to chapter 5.6.  
Since the µP channel set-up at the CFI only allows a channel bandwidth of 64 kbit/s, the  
synchronous transfer utility also allows only 64 kbit/s channels at the CFI.  
The EPIC generates interrupts guiding through the synchronous transfer. Upon the  
ISTA:SIN interrupt the data registers STDA (STDB) may be accessed for some time. If  
the data register of an active channel has not been accessed at the end of this time  
interval the ISTA:SOV interrupt is generated, before the EPIC performs the transfer to  
the selected memory locations. If the µP fails to overwrite the data register with a new  
value, the value previously received from the time slot pointed to by SARA (SARB) will  
be transmitted. The ISTA:SIN and SOV interrupts are generated periodically at fixed  
time points within the frame regardless of the actual positions of the involved time slots.  
The repetition cycle of the synchronous transfer is identical to a frame length (125 µs).  
The access window is closed for at most, 16 RCL periods per active channel + 1 RCL  
period, leaving a very long access time.  
This behavior is also shown in figure 76:  
Frame n  
Frame n + 1  
max. 17 (33) RCL Periods  
125 µs  
STCR : TAE(TBE) = 1  
SIN  
(SOV) SIN  
(SOV) SIN  
µP Access Window Open  
µP Access Window Open  
ITD08092  
Figure 76  
Synchronous Transfer Flow Diagram  
Example  
In a typical IOM-2 application, the RCL frequency is 4.096 MHz, i.e. an RCL period lasts  
244 ns. The IOM-2 frame duration is 125 µs. If one synchronous channel is enabled, the  
access window is open for 121 µs and closed for 4 µs. If both synchronous channels are  
enabled, the access window is open for 117 µs and closed for 8 µs.  
Semiconductor Group  
214  
 
PEB 2055  
PEF 2055  
Application Hints  
5.7.1  
Registers Used in Conjunction with the Synchronous Transfer Utility  
Synchronous Transfer Data  
Register A  
read/write reset value:  
undefined  
bit 0  
bit 7  
STDA:  
MTDA7 MTDA6 MTDA4 MTDA3 MTDA2 MTDA1 MTDA0  
The STDA register buffers the data transferred over the synchronous transfer channel A.  
MTDA7 to MTDA0 hold the bits 7 to 0 of the respective time slot. MTDA7 (MSB) is the  
bit transmitted/received first, and MTDA0 (LSB) the bit transmitted/received last over the  
serial interface.  
Synchronous Transfer Data  
Register B  
read/write reset value:  
undefined  
bit 0  
bit 7  
STDB:  
MTDB7 MTDB6 MTDB5 MTDB4 MTDB3 MTDB2 MTDB1 MTDB0  
The STDB register buffers the data transferred over the synchronous transfer channel B.  
MTDB7 to MTDB0 hold the bits 7 to 0 of the respective time slot. MTDB7 (MSB) is the  
bit transmitted/received first, MTDB0 (LSB) the bit transmitted/received last over the  
serial interface.  
Synchronous Transfer Receive  
Address Register A  
read/write reset value:  
undefined  
bit 0  
bit 7  
SARA:  
ISRA MTRA6 MTRA5 MTRA4 MTRA3 MTRA2 MTRA1 MTRA0  
The SARA register specifies for synchronous transfer channel A from which input  
interface, port, and time slot the serial data is extracted. This data can then be read from  
the STDA register.  
ISRA:  
Interface Select Receive for channel A; selects the PCM interface  
(ISRA = 0) or the CFI (ISRA = 1) as the input interface for  
synchronous channel A.  
Semiconductor Group  
215  
PEB 2055  
PEF 2055  
Application Hints  
MTRA6 … 0:  
µP Transfer Receive Address for channel A; selects the port and time  
slot number at the interface selected by ISRA according to figure 48:  
MTRA6 … 0 = MA6 … 0.  
Synchronous Transfer Receive  
Address Register B  
read/write reset value:  
undefined  
bit 0  
bit 7  
SARB:  
ISRB MTRB6 MTRB5 MTRB4 MTRB3 MTRB2 MTRB1 MTRB0  
The SARB register specifies for synchronous transfer channel B from which input  
interface, port, and time slot the serial data is extracted. This data can then be read from  
the STDB register.  
ISRB:  
Interface Select Receive for channel B; selects the PCM interface  
(ISRB = 0) or the CFI (ISRB = 1) as the input interface for  
synchronous channel B.  
MTRB6 … 0:  
µP Transfer Receive Address for channel B; selects the port and time  
slot number at the interface selected by ISRB according to figure 48:  
MTRB6 … 0 = MA6 … 0.  
Synchronous Transfer Transmit  
Address Register A  
read/write reset value:  
undefined  
bit 0  
bit 7  
SAXA:  
ISXA MTXA6 MTXA5 MTXA4 MTXA3 MTXA2 MTXA1 MTXA0  
The SAXA register specifies for synchronous transfer channel A to which output  
interface, port, and time slot the serial data contained in the STDA register is sent.  
ISXA:  
Interface Select Transmit for channel A; selects the PCM interface  
(ISXA = 0) or the CFI (ISXA = 1) as the output interface for  
synchronous channel A.  
MTXA6 … 0:  
µP Transfer Transmit Address for channel A; selects the port and time  
slot number at the interface selected by ISXA according to figure 48:  
MTXA6 … 0 = MA6 … 0.  
Semiconductor Group  
216  
PEB 2055  
PEF 2055  
Application Hints  
Synchronous Transfer Transmit  
Address Register B  
read/write reset value:  
undefined  
bit 7  
bit 0  
SAXB:  
ISXB MTXB6 MTXB5 MTXB4 MTXB3 MTXB2 MTXB1 MTXB0  
The SAXB register specifies for synchronous transfer channel B to which output  
interface, port, and time slot the serial data contained in the STDB register is sent.  
ISXB:  
Interface Select Transmit for channel B; selects the PCM interface  
(ISXB = 0) or the CFI (ISXB = 1) as the output interface for  
synchronous channel B.  
MTXB6 … 0:  
µP Transfer Transmit Address for channel B; selects the port and time  
slot number at the interface selected by ISXB according to figure 48:  
MTXB6 … 0 = MA6 … 0.  
Synchronous Transfer Control  
Register STCR  
read/write reset value:  
undefined  
bit 0  
bit 7  
STCR:  
TBE  
TAE  
CTB2  
CTB1  
CTB0  
CTA2  
CTA1  
CTA0  
The STCR register bits are used to enable or disable the synchronous transfer utility and  
to determine the subtime slot bandwidth and position if a PCM interface time slot is  
involved.  
TAE, TBE:  
Transfer Channel A (B) Enable; A logical 1 enables the µP transfer, a  
logical 0 disables the transfer of the corresponding channel.  
CTA2 … 0:  
CTB2 … 0:  
Channel Type A (B); these bits determine the bandwidth of the  
channel and the position of the relevant bits in the time slot according  
to table 33. Note that if a CFI time slot is selected as receive or  
transmit time slot of the synchronous transfer, the 64 kbit/s bandwidth  
must be selected (CT#2 … CT#0 = 001).  
Semiconductor Group  
217  
PEB 2055  
PEF 2055  
Application Hints  
Table 33  
CT#2  
CT#1  
CT#0  
Bandwidth  
Transferred Bits  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
not allowed  
64 kbit/s  
32 kbit/s  
32 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
16 kbit/s  
bits 7 … 0  
bits 3 … 0  
bits 7 … 4  
bits 1 … 0  
bits 3 … 2  
bits 5 … 4  
bits 7 … 6  
Semiconductor Group  
218  
PEB 2055  
PEF 2055  
Application Hints  
Interrupt Status Register  
read/write reset value:  
00H  
bit 7  
bit 0  
ISTA:  
TIN  
SFI  
MFFI  
MAC  
PFI  
PIM  
SIN  
SOV  
The ISTA register should be read after an interrupt in order to determine the interrupt  
source. Two maskable (MASK) interrupts are provided in connection with the  
synchronous transfer utility:  
SIN:  
Synchronous Transfer Interrupt; The SIN interrupt is enabled if at  
least one synchronous transfer channel (A and/or B) is enabled via  
the STCR:TAE, TBE bits. The SIN interrupt is generated when the  
access window for the µP opens. After the occurrence of the SIN  
interrupt (logical 1) the µP can read and/or write the synchronous  
transfer data registers (STDA, STDB). The window where the µP can  
access the data registers is open for the duration of one frame  
(125 µs) minus 17 RCL cycles if only one synchronous channel is  
enabled and it is open for one frame minus 33 RCL cycles if both A  
and B channels are enabled. The SIN bit is reset by reading ISTA.  
SOV:  
Synchronous Transfer Overflow; The SOV interrupt is generated  
(logical 1) if the µP fails to access the data registers (STDA, STDB)  
within the access window. The SOV bit is reset by reading ISTA.  
Semiconductor Group  
219  
PEB 2055  
PEF 2055  
Application Hints  
Examples  
1) In PCM mode 0, the synchronous transfer utility (channel A) shall be used to loop  
bits 7 … 6 of downstream PCM port 1, time slot 5 back to bits 7 … 6 of upstream  
PCM port 2, time slot 9. Since no µP access to the data is required the ISTA:SIN and  
SOV bits are both masked:  
W:MASK = 03H ; SIN = SOV = 1  
W:SARA = 13H ; ISRA = 0, port 1, TS5  
W:SAXA = 25H ; ISXA = 0, port 2, TS9  
W:STCR = 47H ; TAE = 1, CTA2 … 0 = 111 (bits 7 … 6)  
2) In PCM mode 0 and CFI mode 0, the µP shall have access to both the downstream  
and upstream CFI port 0, time slot 1 via the synchronous transfer channel B:  
W:SARB = 81H ; ISRB = 1, port 0, TS1  
W:SAXB = 81H ; ISXB = 1, port 0, TS1  
W:STCR = 88H ; TBE = 1, CTA2 … 0 = 001 (bits 7 … 0)  
Wait for interrupt:  
R:ISTA  
= 02H ; SIN = 1  
R:STDB  
= upstream CFI data  
W:STDB = downstream CFI data  
Wait for next SIN interrupt and transfer further data bytes … .  
Semiconductor Group  
220  
PEB 2055  
PEF 2055  
Application Hints  
5.8  
Supervision Functions  
Hardware Timer  
5.8.1  
Hardware Timer  
The EPIC provides a programmable hardware timer which can be used for three  
purposes:  
– General purpose timer for continuously interrupting the µP at programmable time  
intervals.  
– Timer to define the last look period for signaling channels at the CFI  
(see chapter 5.5.1).  
– Timer to define the FSC multiframe generation at the CFI (CMD2:FC2 … 0 = 111,  
see chapter 5.2.2.3).  
Normally in a system only one of these functions is required and therefore active at a  
time. However, it is also possible to have any combination of these functions active, if it  
is acceptable that all three applications use the same timer value.  
The timer period can be selected from 250 µs up to 32 ms in increments of 250 µs.  
T
T
Timer Start  
CMDR : ST = 1  
(CMDR : TIG = 1)  
(ISTA : TIN)  
LL Sampling  
Multifr. Sync.  
(ISTA : TIN)  
LL Sampling  
Multifr. Sync.  
Timer Stop  
TIMR = XX  
T = (TVAL6...0 + 1) x 250 µs  
LL : Last Look  
ITD08093  
Figure 77  
Timer Applications  
Semiconductor Group  
221  
PEB 2055  
PEF 2055  
Application Hints  
The following register bits are used in conjunction with the hardware timer:  
Timer Register  
write  
reset value:  
00H  
bit 7  
bit 0  
TVAL6 TVAL5 TVAL4 TVAL3 TVAL2 TVAL1 TVAL0  
TIMR:  
SSR  
Writing to the TIMR register stops the timer operation!  
SSR:  
Signaling Channel Sample Rate; this bit actually does not affect the  
timer operation. It is used to select between a fixed last look period  
for signaling channels of 125 µs (SSR = 1), which is independent of  
the timer operation and a signaling sample rate that is defined by the  
timer period (SSR = 0).  
TVAL6 … 0:  
Timer Value; The timer period is programmed here in increments of  
250 µs:  
Timer period = (TVAL6 … 0 + 1) × 250 µs  
Command Register  
write  
reset value:  
00H  
bit 7  
bit 0  
MFT0 MFSO MFR  
CMDR  
ST:  
0
ST  
TIG  
CFR  
MFT1  
Start Timer; setting this bit to logical 1 starts the timer to run cyclically  
from 0 to the value programmed in TIMR:TVAL6 … 0. Setting this bit  
to logical 0 does not affect the timer operation. If the timer shall be  
stopped, the TIMR register must simply be written with a random  
value.  
TIG:  
Timer Interrupt Generation; setting this bit together with CMDR:ST to  
logical 1 causes the EPIC to generate a periodic interrupt (ISTA:TIN)  
each time the timer expires. Setting the TIG bit to logical 0 together  
with the CMDR:ST bit set to logical 1 disables the interrupt  
generation. It should be noted that this bit only controls the ISTA:TIN  
interrupt generation and need not be set for the ISTA:SFI interrupt  
generation.  
Semiconductor Group  
222  
PEB 2055  
PEF 2055  
Application Hints  
Interrupt Status Register  
read/write reset value:  
00H  
bit 7  
bit 0  
ISTA:  
TIN  
SFI  
MFFI  
MAC  
PFI  
PIM  
SIN  
SOV  
The ISTA register should be read after an interrupt in order to determine the interrupt  
source. In connection with the hardware timer one maskable (MASK) interrupt bit is  
provided by the EPIC:  
TIN:  
Timer Interrupt; if this bit is set to logical 1, a timer interrupt previously  
requested with CMDR:ST,TIG = 1 has occurred. The TIN bit is reset  
by reading ISTA. It should be noted that the interrupt generation is  
periodic, i.e. unless stopped by writing to TIMR, the ISTA:TIN will be  
generated each time the timer expires.  
Status Register  
read  
reset value:  
05H  
bit 7  
bit 0  
MFTO MFAB MFAE MFRW MFFE  
STAR:  
MAC  
TAC  
PSS  
The STAR register bits do not generate interrupts and are not modified by reading  
STAR.  
TAC:  
Timer Active; While the timer is running (CMDR:ST=1) the TAC bit is  
set to logical 1. The TAC bit is reset to logical 0 after the timer has  
been stopped (W:TIMR = XX).  
5.8.2  
PCM Input Comparison  
To simplify the realization of redundant PCM transmission lines, the EPIC can be  
programmed to compare the contents of certain pairs of its PCM input lines. If a pair of  
lines carry the same information (normal case), nothing happens. If however the two  
lines differ in at least one bit (error case), the EPIC generates an ISTA:PIM interrupt and  
indicates in the PICM register the pair of input lines and the time slot number that caused  
that mismatch.  
The comparison function is carried out between the pairs of physical PCM input lines  
RxD0/RxD1 and RxD2/RxD3. It can be activated in all PCM modes, including PCM  
mode 0. However, a redundant PCM input line that can be switched over to by means of  
the PMOD:AIS1 … 0 bits is of course only available in PCM modes 1 and 2.  
Semiconductor Group  
223  
PEB 2055  
PEF 2055  
Application Hints  
The following register bits are used in conjunction with the PCM input comparison  
function:  
PCM Mode Register  
read/write reset value:  
00H  
bit 7  
bit 0  
AIC1 AIC0  
PMOD:  
PMD1  
PMD0  
PCR  
PSM  
AIS1  
AIS0  
AIC1 … 0:  
Alternative Input Comparison 1 and 0.  
AIC0 set to logical 1 enables the comparison function between RxD0  
and RxD1.  
AIC1 set to logical 1 enables the comparison function between RxD2  
and RxD3.  
AIC1, AIC0 set to logical 0 disables the respective comparison  
function.  
In PCM mode 2, AIC0 must be set to logical 0.  
Interrupt Status Register  
read  
reset value:  
00H  
bit 7  
bit 0  
SOV  
ISTA:  
TIN  
SFI  
MFFI  
MAC  
PFI  
PIM  
SIN  
The ISTA register should be read after an interrupt in order to determine the interrupt  
source. In connection with the PCM comparison function one maskable (MASK) interrupt  
bit is provided by the EPIC:  
PIM:  
PCM Input Mismatch; this bit is set to logical 1 immediately after the  
comparison logic has detected a mismatch between a pair of PCM  
input lines. The exact reason for the interrupt can be determined by  
reading the PICM register. Reading ISTA clears the PIM bit. A new  
PIM interrupt can only be generated after the PICM register has been  
read.  
Semiconductor Group  
224  
PEB 2055  
PEF 2055  
Application Hints  
PCM Input Comparison Mismatch  
read  
reset value:  
undefined  
bit 7  
bit 0  
PICM:  
IPN  
TSN6  
TSN5  
TSN4  
TSN3  
TSN2  
TSN1  
TSN0  
The contents of the PICM register is only valid after an ISTA:PIM interrupt!  
The PICM register must be read after an ISTA:PIM interrupt in order to enable a new  
PIM interrupt generation.  
IPN:  
Input Pair Number; this bit indicates the pair of input lines where a  
mismatch occurred. A logical 0 indicates a mismatch between lines  
RxD0 and RxD1, a logical 1 between lines RxD2 and RxD3.  
TSN6 … 0:  
Table 34  
Time slot Number 6 … 0; these bits specify the time slot number and  
the bit positions that generated the ISTA:PIM interrupt according to  
the table below. TPF denotes the number of time slots per PCM frame  
PCM Mode  
Time Slot Identification  
[TSN6 … 0 + 8]mod TPF  
[TSN6 … 1 + 4]mod TPF  
Bit Identification  
2
1
TSN0 = 1 : bits 3 … 0  
TSN0 = 0 : bits 7 … 4  
0
[TSN6 … 2 + 2]mod TPF  
TSN1 … 0 = 11 : bits 1 … 0  
TSN1 … 0 = 10 : bits 3 … 2  
TSN1 … 0 = 01 : bits 5 … 4  
TSN1 … 0 = 00 : bits 7 … 6  
Example  
In PCM mode 1, the logical PCM port 0 is connected to two physical PCM transmission  
links. The comparison function for RxD0/RxD1 is enabled via PMOD:AIC0 = 1. Suddenly  
a bit error occurs at one of the receive lines in time slot 13, bit 2. The µP would then get  
the following information from the EPIC:  
Interrupt!  
R: ISTA  
R: PICM  
= 04H  
= 13H  
; PIM interrupt  
; IPN = 0, TSN6 … 1 = 9, TSN0 = 1  
In order to determine the line actually at fault (RxD0 or RxD1) the system must send a  
known pattern in one of the time slots and compare the actually received value with that  
known pattern.  
Semiconductor Group  
225  
PEB 2055  
PEF 2055  
Application Hints  
EPIC R  
Physical Pins:  
TXD0  
Logical Ports  
PCM Transmission  
Line #1  
OUT0  
TSC0  
RXD0  
TSC0  
IN0  
Line Drivers  
& Receivers  
1
PCM Transmission  
Line #2  
0
RXD1  
TSC1  
PMOD : AIS0  
ISTA : PIM  
=1  
ITD08094  
Figure 78  
Connection of Redundant PCM Transmission Lines to the EPIC®  
5.8.3  
PCM Framing Supervision  
Usually the repetition rate of the applied framing pulse PFS is identical to the frame  
period (125 µs). If this is the case, the ’loss of synchronism indication function’ can be  
used to supervise the clock and framing signals for missing or additional clock cycles.  
The EPIC internally checks the PFS period against the duration expected from the  
programmed clock rate. The clock rate corresponds to the frequency applied to the PDC  
pin. The number of clock cycles received within one PFS period is compared with the  
values programmed to PBNR (number of bits per frame) and PMOD:PCR (single/double  
clock rate operation). If for example single clock rate operation with 24 time slots per  
frame is programmed, the EPIC expects 192 clock cycles within one PFS period. The  
synchronous state is reached after the EPIC has detected two consecutive correct  
frames. The synchronous state is lost if one erroneous frame is found. The  
synchronization status (gained or lost) can be read from the STAR register (PSS bit) and  
each status change generates an interrupt (ISTA:PFI).  
It should be noted that the framing supervision function is optional, i.e. it is also allowed  
to apply a PFS signal having a period of several frame periods e.g. 4 kHz, 2 kHz, … .  
The STAR:PSS bit will then be at logical 0 all the time, which does however not affect  
the proper operation of the EPIC.  
Semiconductor Group  
226  
PEB 2055  
PEF 2055  
Application Hints  
The following register bits are used in conjunction with the PCM framing supervision:  
Interrupt Status Register  
read/write reset value:  
00H  
bit 7  
bit 0  
SOV  
ISTA:  
TIN  
SFI  
MFFI  
MAC  
PFI  
PIM  
SIN  
The ISTA register should be read after an interrupt in order to determine the interrupt  
source. In connection with the PCM framing control one maskable (MASK) interrupt bit  
is provided by the EPIC:  
PFI:  
PCM Framing Interrupt; if this bit is set to logical 1, the STAR:PSS bit  
has changed its polarity. To determine whether the PCM interface is  
synchronized or not, STAR must be read. The PFI bit is reset by  
reading ISTA.  
Status Register  
read  
reset value:  
05H  
bit 7  
bit 0  
MFTO MFAB MFAE MFRW MFFE  
STAR:  
MAC  
TAC  
PSS  
The STAR register bits do not generate interrupts and are not modified by reading  
STAR. However, each change of the PSS bit (0 1 and 1 0) causes an ISTA:PFI  
interrupt.  
PSS:  
PCM Synchronization Status; while the PCM interface is  
synchronized, the PSS bit is set to logical 1. The PSS bit is reset to  
logical 0 if there is a mismatch between the PBNR value and the  
applied clock and framing signals (PDC/PFS) or if OMDR:OMS0 = 0.  
5.8.4  
Power and Clock Supply Supervision/Chip Version  
Power and Clock Supply Supervision  
The + 5 V power supply line (VDD) and the reference clock (RCL) are continuously  
checked by the EPIC for spikes that may disturb the proper operation of the EPIC. If such  
an inappropriate clocking or power failure occurs, data in the internal memories may be  
lost, and a reinitialization of the EPIC is necessary. An Initialization Request status bit  
(VNSR:IR) can be interrogated periodically by the µP to determine the current status of  
the device.  
In normal chip operation, the IR bit should never be set, not even after power on or when  
the clock signals are switched on and off. The IR bit will only be set if spikes (< 10 ns)  
are detected on the clock and power lines which may affect the data transfer on the EPIC  
internal buses.  
Semiconductor Group  
227  
PEB 2055  
PEF 2055  
Application Hints  
5.9  
Applications  
Analog IOM®-2 Line Card with SICOFI®-4 as Codec/Filter Device  
5.9.1  
The line card consists of an EPIC (PEB 20550) device which handles the monitor and  
the signaling channels of up to 16 SICOFI-4 (PEB 2465) devices. Since each SICOFI-4  
supports four analog lines, up to 64 analog subscriber lines (t/r lines) can be  
accommodated.  
Figure 79 shows the interconnection of the EPIC, and the SICOFI-4 devices via the  
IOM-2 interface:  
+5V  
+5V  
1kΩ  
1kΩ  
R
Quadruple Codec Filter  
DCL  
EPIC  
Analog  
Lines  
4096 kHz  
DCL  
FSC  
DD0  
DU0  
DD1  
DU1  
DD2  
DU2  
DD3  
DU3  
PFS  
PDC  
8 kHz  
8 kHz  
FSC  
4096 kHz  
R
SICOFI -4  
2048 kbit/s  
DIN  
RxD0  
TxD0  
RxD1  
TxD1  
RxD2  
TxD2  
RxD3  
TxD3  
2048 kbit/s  
DOUT  
PCM  
Backplane  
Quadruple Codec Filter  
DCL  
Analog  
Lines  
2048 kbit/s or  
4096 kbit/s  
FSC  
R
SICOFI -4  
DIN  
DOUT  
R
4 x IOM -2 Ports  
Signaling  
High  
Backplane  
HSCX  
Up to 4 Devices per  
IOM -2 Port  
R
µ
P
ITS09552  
Figure 79  
Analog Line Card with SICOFI®-4 Devices Using the IOM®-2 Interface  
A typical timing example for the connection of the line card to a 2.048 Mbit/s PCM  
backplane is shown in figure 80. It should be noted that the PCM interface must be  
clocked with a 4.096 MHz clock even if the PCM interface operates at only 2.048 Mbit/s.  
This is to obtain a DCL output frequency of 4.096 MHz, which is required for the IOM-2  
timing.  
Semiconductor Group  
228  
 
PEB 2055  
PEF 2055  
Application Hints  
PFS  
PDC  
TxD#  
RxD#  
TS31, Bit 0  
TS31, Bit 0  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
...  
FSC  
DCL  
DD#  
DU#  
TS31, Bit 0  
TS31, Bit 0  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
...  
ITT08096  
Figure 80  
Typical IOM®-2 Line Card Timing  
Based on these PCM and CFI timing requirements, the following EPIC initialization  
values for the PCM and CFI registers are recommended:  
EPIC®  
PMOD = 0010 0000B = 20H PCM mode 0, double rate clock, PFS evaluated  
with falling clock edge, PCM comparison disabled  
PBNR = 1111 1111B = FFH 256 bits (32 ts) per PCM frame  
POFD = 1111 0000B = F0H PFS marks downstream PCM TS0, bit 7  
POFU = 0001 1000B = 18H PFS marks upstream PCM TS0, bit 7  
PCSR = 0000 0001B = 01H PCM data received with falling, transmitted with  
rising clock edge  
CMD1 = 0010 0000B = 20H PDC/PFS clock source, PFS evaluated with falling  
clock edge, prescaler = 1, CFI mode 0  
CMD2 = 1101 0000B = D0H FC mode 6, double rate clock, CFI data  
transmitted with rising, received with falling clock  
edge  
CBNR = 1111 1111B = FFH 256 bits (32 ts) per CFI frame  
Semiconductor Group  
229  
PEB 2055  
PEF 2055  
Application Hints  
CTAR = 0000 0010B = 02H PFS marks downstream CFI TS0  
CBSR = 0010 0000B = 20H PFS marks downstream CFI bit 7, upstream bits  
not shifted  
CSCR = 0000 0000B = 00H 64, 32, 16 kbit/s channels located on CFI TS bits  
7 … 0, 7 … 4, 7 … 6  
Each SICOFI-4 device must be assigned to its individual IOM-2 channels by  
pin-strapping. The SICOFI-4 coefficients (filter characteristics, gain, … ) as well as other  
operation parameters, are programmed via the ELIC over the IOM-2 monitor channel.  
Example  
Initializing 4 consecutive CFI time slots as an analog IOM-2 channel.  
Time slots 0, 1, 2, and 3 of CFI port 2 shall represent the IOM channel 0 of port 2. Time  
slots 4, 5, 6, and 7 of CFI port 2 shall represent the IOM channel 1 of port 2. This requires  
the SICOFI-4 to be pin-strapped to that slot by connecting pin TSS0 and pin TSS1 to 0 V.  
Time slots 4 and 5 represent the two B channels that may for example be switched to  
the PCM interface. Time slots 6 and 7 represent the monitor and signaling (SIG)  
channels and must be initialized in the ELIC control memory (CM):  
W: MADR = FFH  
W:MAAR = 1CH  
W: MACR = 7AH  
W: MADR = FFH  
W: MAAR = 1DH  
W: MACR = 7BH  
W: MADR = FFH  
W: MAAR = 9CH  
W: MACR = 7AH  
W: MADR = FFH  
W: MAAR = 9DH  
W: MACR = 7AH  
; 6 bit signaling value to be transmitted in time slot 7  
; CFI address of downstream IOM port 2, time slot 6  
; writing CM with code ‘1010’  
; value don’t care, e.g. FF  
; CFI address of downstream IOM port 2, time slot 7  
; writing CM with code ‘1011’  
; 6 bit signaling value expected upon initialization in time slot 7  
; CFI address of upstream IOM port 2, time slot 6  
; writing CM with code ‘1010’  
; 6 bit signaling value expected upon initialization in time slot 7  
; CFI address of upstream IOM port 2, time slot 7  
; writing CM with code ‘1010’  
The above steps have to be repeated for all time slots that shall be handled by the  
monitor or signaling handler of the EPIC (i.e. TS2 and TS3, TS10 and TS11, TS14  
and TS15).  
Semiconductor Group  
230  
PEB 2055  
PEF 2055  
Application Hints  
Example for programming the CODEC corresponding to TS6 of the SICOFI-4:  
W: OMDR = EEH  
W: MFSAR = 0EH  
W: CMDR = 01H  
R: STAR = 25H  
W: MFFIFO= 81H  
; activation of ELIC with active handshake protocol  
; monitor address for port 2, time slot 6  
; MFFIFO reset  
; MFFIFO write access enabled  
; SICOFI-4 monitor address  
W: MFFIFO= 14 H(94H) ; SICOFI-4 channel A (B) data  
W: MFFIFO= 00H  
W: MFFIFO= 00H  
W: MFFIFO= 00H  
W: MFFIFO= 00H  
W: CMDR = 04H  
; SICOFI-4 data  
; SICOFI-4 data  
; SICOFI-4 data  
; SICOFI-4 data  
; transmit command  
Wait for interrupt!  
R: ISTA  
= 20H; MFFI interrupt  
R: STAR = 25H; transfer completed, MFFIFO write access enabled  
Reading back data from SICOFI-4:  
W: MFSAR = 0EH  
W: CMDR = 01H  
R: STAR = 25H  
W: MFFIFO= 81H  
; monitor address for port 2, time slot 6  
; MFFIFO reset  
; MFFIFO write access enabled  
; SICOFI-4 monitor address  
W: MFFIFO= 65H(E5H) ; SICOFI-4 channel A (B) data, read back request  
W: CMDR = 08H  
; transmit and receive command  
Wait for interrupt!  
R: ISTA  
= 20H  
; MFFI interrupt  
R: STAR = 26H  
; transfer completed, MFFIFO not empty, read access  
enabled  
R: MFFIFO = 81H  
R: MFFIFO = 00H  
R: MFFIFO = 00H  
R: MFFIFO = 00H  
R: MFFIFO = 00H  
R: STAR = 27H  
; SICOFI-4 monitor address  
; SICOFI-4 data  
; SICOFI-4 data  
; SICOFI-4 data  
; SICOFI-4 data  
; transfer completed, MFFIFO empty, read access enabled  
Semiconductor Group  
231  
PEB 2055  
PEF 2055  
Application Hints  
5.9.2  
IOM®-2 Trunk Line Applications  
Trunk lines connect the PBX to the central office (CO) network. Figure 81 gives an  
overview of the different access possibilities to the central office.  
One possibility is to use analog a/b lines. This is the most uncomplicated way since no  
clock recovery from the CO is required, i.e. the PBX operates with a free running crystal  
oscillator. The t/r access to the CO can easily be realized with one or several SICOFI-2  
or SICOFI-4 codec/filter devices, which allow the connection of two or four analog lines  
per chip.  
If an access to the ISDN world is desired, two options are possible:  
For small PBXs, with only few external lines, one or several Basic Rate ISDN (BRI)  
connections are best suited. Each BRI connection provides a capacity of two B channels  
of 64 kbit/s and one D channel of 16 kbit/s. The BRI connection is usually performed via  
the T interface to the Network Terminator 1 (NT1). The T interface is physically identical  
to the S interface, all Siemens S0 interface devices (QUAT-S, SBCX, ISAC-S, SBC) can  
be used for that purpose. A PBX can also be connected directly via the Uk- interface to  
the CO. In this case an IEC-Q device (2B1Q encoding) or an IEC-T (4B3T encoding) can  
be used as layer-1 device.  
PCM/Signaling  
Backplane  
PBX Trunk Line Card  
IOM R -2  
Central Office  
PCM  
t/r  
t/r  
Analog  
Line  
Analog  
Line  
SICOFI R -2  
SICOFI R -4  
R
EPIC  
U
SBCX  
QUAT -S  
T
Basic Rate  
ISDN  
R
k
IDEC  
NT1  
R
U
k
Basic Rate  
ISDN  
IEC-Q  
µ
P
HSCX  
S
U
U
Primary Rate  
(CEPT, T1)  
2m  
k2  
g2  
FALCTM 54  
NT1  
ITS09553  
Figure 81  
Overview of Trunk Line Applications  
Semiconductor Group  
232  
 
PEB 2055  
PEF 2055  
Application Hints  
For large PBXs, with many external lines, one or several Primary Rate ISDN (PRI)  
connections are more advantageous. If the European CEPT standard is used, each PRI  
connection provides 30 B channels of 64 kbit/s each and one D channel of 64 kbit/s. The  
FALC54 can be used to implement the Primary Rate S2m interface according to the  
CEPT (2.048 Mbit/s) or the T1 (1.544 Mbit/s) standards. For both standards a common  
backplane data rate of 2.048 or 4.096 Mbit/s can be selected to simplify the connection  
to the PBX internal PCM highway, which usually consists of 32 or 64 time slots.  
Digital trunk lines require a clock recovery from the received data stream such that the  
PBX clock system is locked up with the CO clock system. The examples given in the  
following chapters show how to deal with these points.  
5.9.2.1 PBX With Multiple ISDN Trunk Lines  
In a trunk unit special attention must be given to the clock synchronization. The PBX  
clock generator must deliver a stable free running clock as long as no external calls are  
active. When an external call is established, the CO must be taken as reference to  
synchronize the local PBX clock system.  
The Siemens S0-layer-1 transceivers SBC, SBCX, QUAT-S and ISAC-S are prepared  
for this kinds of applications: In the LT-T (Line Termination at the T-reference point)  
mode, they deliver a clock signal that is synchronous to the incoming S-frame. This clock  
signal can be taken to synchronize the PCM clocks of the EPIC by means of a XTAL  
controlled PLL circuit. Since the EPIC generates the IOM-2 clocks for the connected  
layer-1 and layer-2 devices, the loop is closed. If several layer-1 devices are operated in  
LT-T mode, only 1 device may be selected to deliver the reference clock. The PBX  
software must determine an active line by evaluating the C/I indications of the layer-1  
devices in order to select an appropriate clock source for the PLL. If several external  
lines are active, any of these lines can be taken, since the CO lines are synchronous  
among each other.  
The layer-1 devices have a built-in frame buffer that compensates the phase offset that  
may persist between the IOM-2 frame and the S0-frame. This buffer is ‘elastic’, such that  
a frame wander and jitter between the IOM-2 and the S-frame can be tolerated up to a  
certain extent. The maximum ‘wander’ value is device specific. For the SBCX, for  
example, 50µs of frame deviation are internally compensated. If this value is exceeded,  
a frame slip occurs that is reported to the µP by a ‘slip’ indication in the C/I code. If a  
frame slip occurs, the data of an S-frame may be lost or transferred twice. The slip  
indications can be evaluated for statistical purposes. However, in a final design with  
optimized PLL tracking, slips should not occur during normal operation of the PBX.  
Since the S0 interface allows bus configurations for terminals (TEs), and since it is  
physically possible to connect a PBX trunk line together with other PBX trunk lines, or  
with normal ISDN terminals, to a common S-bus, the trunk lines must also follow the  
D-channel access procedure specified for ISDN terminals. This D-channel access  
procedure is implemented in the QUAT-S, ISAC-S and SBCX devices and can optionally  
Semiconductor Group  
233  
PEB 2055  
PEF 2055  
Application Hints  
be set. If not required, the D-channel can also be sent transparently. If the QUAT-S is  
used together with the IDEC as layer-2 controller, the IDEC must be informed about the  
availability of the D-channel at the T-interface. The QUAT-S provides an enable signal  
at pin DRDY that carries this information during the D-channel time slot. This signal can  
be connected to the collision data input (CDR) of the IDEC to enable or disable HDLC  
transmission. The IDEC must then be programmed to the ‘slave mode’ in order to  
evaluate the CDR pin.  
Figure 82 illustrates a complete PBX trunk card, where the EPIC controls up to  
8 QUAT-S devices connected to up to 4 IOM-2 ports. On each IOM-2 port 2 IDECs take  
care of the D-channel processing. The CDR input lines of the IDECs are connected with  
the DRDY output pins of the QUAT-S. This is to stop the HDLC controllers in case of a  
D-channel collision on the T-bus. The QUAT-S devices must be programmed via the  
monitor channel to deliver appropriate Stop/Go information at pin DRDY. The 1.536 MHz  
reference clock outputs (pin CLK1) of the QUAT-Ss are fed via a multiplexer to the PBX  
clock generator. The µP controls the multiplexer as required by the state of the lines.  
Semiconductor Group  
234  
PEB 2055  
PEF 2055  
Application Hints  
CDR  
DCL  
ESC  
SD0X  
SD0R  
CDR  
DCL  
ESC  
SD0X  
SD0R  
Figure 82  
PBX Trunk Card for Multiple Basic Rate Trunk Lines Using the QUAT®-S  
Semiconductor Group  
235  
PEB 2055  
PEF 2055  
Application Hints  
Initialization values for the IDEC that controls the lower 4 channels of the IOM-2  
interface:  
IDEC®  
CCR  
= 1000 0010B = 82H IOM-2 mode, IOM ch. 0 - 3, double clock rate,  
256 bits/frame  
A_MODE  
= 0000 1100B = 0CH uncond. trans., 16 kbit/s ch., channel and  
receiver active  
A_TSR  
B_MODE  
= 0000 1100B = 0CH ch. A time slot position: D channel of IOM ch. 0  
= 0000 1100B = 0CH uncond. trans., 16 kbit/s ch., channel and  
receiver active  
B_TSR  
C_MODE  
= 0001 1100B = 1CH ch. B time slot position: D channel of IOM ch. 1  
= 0000 1100B = 0CH uncond. trans., 16 kbit/s ch., channel and  
receiver active  
C_TSR  
D_MODE  
= 0010 1100B = 2CH ch. C time slot position: D channel of IOM ch. 2  
= 0000 1100B = 0CH uncond. trans., 16 kbit/s ch., channel and  
receiver active  
D_TSR  
= 0011 1100B = 3CH ch. D time slot position: D channel of IOM ch. 3  
Initialization values for the IDEC that controls the upper 4 channels of the IOM-2  
interface:  
IDEC®  
CCR  
= 1000 0010B = A2H IOM-2 mode, IOM ch. 4-7, double clock rate,  
256 bits/frame  
A_MODE  
= 0000 1100B = 0CH uncond. trans., 16 kbit/s ch., channel and  
receiver active  
A_TSR  
B_MODE  
= 0100 1100B = 4CH ch. A time slot position: D channel of IOM ch. 4  
= 0000 1100B = 0CH uncond. trans., 16 kbit/s ch., channel and  
receiver active  
B_TSR  
C_MODE  
= 0101 1100B = 5CH ch. B time slot position: D channel of IOM ch. 5  
= 0000 1100B = 0CH uncond. trans., 16 kbit/s ch., channel and  
receiver active  
C_TSR  
D_MODE  
= 0110 1100B = 6CH ch. C time slot position: D channel of IOM ch. 6  
= 0000 1100B = 0CH uncond. trans., 16 kbit/s ch., channel and  
receiver active  
D_TSR  
= 0111 1100B = 7CH ch. D time slot position: D channel of IOM ch. 7  
The ELIC initialization is the same as for the IOM-2 application described previously in  
this chapter.  
Semiconductor Group  
236  
PEB 2055  
PEF 2055  
Application Hints  
If the D-channel access procedure is programmed, the IDEC MODE registers must  
additionally be programmed accordingly i.e. for each channel MODE = 2CH (instead  
of 0CH).  
Example  
In a first step, the QUAT-S in IOM port 0, ch. 0 … 3 is programmed via the IOM-2 monitor  
handler to the LT-T mode:  
W:OMDR  
W:MFSAR = 04H  
W:CMDR  
R:STAR  
W:MFFIFO = 81H  
W:MFFIFO = 41H  
= EEH  
; activation ELIC with handshake protocol enabled  
; monitor address of IOM port 0, channel 0  
; reset MFFIFO  
; MFFIFO write access enabled  
; select QUAT-S Configuration Register  
; set LT-T mode, output CLK1  
; transmit MFFIFO content  
; MFFI interrupt  
= 01H  
= 25H  
W:CMDR  
R:ISTA  
= 04H  
= 20H  
W:MFSAR = 0CH  
; monitor address of IOM port 0, channel 1  
; reset MFFIFO  
; MFFIFO write access enabled  
; select QUAT-S Configuration Register  
; set LT-T mode  
W:CMDR  
R:STAR  
= 01H  
= 25H  
W:MFFIFO = 81H  
W:MFFIFO = 01H  
W:CMDR  
R:ISTA  
= 04H  
= 20H  
; transmit MFFIFO content  
; MFFI interrupt  
W:MFSAR = 14H  
; monitor address of IOM port 0, channel 2  
; reset MFFIFO  
; MFFIFO write access enabled  
; select QUAT-S Configuration Register  
; set LT-T mode  
W:CMDR  
R:STAR  
= 01H  
= 25H  
W:MFFIFO = 81H  
W:MFFIFO = 01H  
W:CMDR  
R:ISTA  
= 04H  
= 20H  
; transmit MFFIFO content  
; MFFI interrupt  
W:MFSAR = 1CH  
; monitor address of IOM port 0, channel 3  
; reset MFFIFO  
; MFFIFO write access enabled  
; select QUAT-S Configuration Register  
; set LT-T mode  
W:CMDR  
R:STAR  
= 01H  
= 25H  
W:MFFIFO = 81H  
W:MFFIFO = 01H  
W:CMDR  
R:ISTA  
= 04H  
= 20H  
; transmit MFFIFO content  
; MFFI interrupt  
Semiconductor Group  
237  
PEB 2055  
PEF 2055  
Application Hints  
5.9.2.2 Small PBX  
Figure 83 shows a realization example of a small PBX. If the total number of lines  
(internal or external) is smaller than the capacity of the EPIC (32 × (2 × B + D) or 64 × B),  
the PCM interface of the EPIC need not to be connected to a switching network since all  
the B (and D) channel switching can be done inside the EPIC. In this special case, it is  
sufficient to apply only a PCM clock to the EPIC, the PCM frame synchronization signal  
(8 kHz) can be omitted. The IOM-2 clock and framing signals DCL and FSC are still  
generated correctly by the EPIC. The STAR:PSS bit should then not be evaluated: it  
stays at logical 0 all the time.  
The PBX shown in the figure 83 offers 8 analog (t/r) subscriber lines, realized with two  
quadruple codec/filter devices SICOFI-4 (PEB 2465). These can of course be replaced  
by any IOM-2 compatible layer-1 device if digital lines are required. Any mixture of  
codecs and digital layer-1 devices is also feasible.  
The figure 83 also shows a digital trunk line (external line) which is realized with a Uk-  
layer-1 device, IEC-Q (PEB 2091), operated in NT-PABX mode. The PBX can therefore  
be connected directly to the Uk interface coming from the CO. The NT-PABX mode of  
the Uk- layer-1 devices is similar to the LT-T mode of the S layer-1 devices: in both cases  
the layer-1 device delivers a reference clock which is synchronous to the received S or  
Uk- frame and that can be used to synchronize the local PBX clock generator. Any phase  
differences between the local IOM-2 frame and the received S or Uk- frame are  
compensated by an elastic buffer inside the layer-1 devices.  
Since the digital trunk line also needs a D channel handler, an ISDN Communication  
Controller (ICC; PEB 2070) is assigned to that IOM-2 channel.  
Semiconductor Group  
238  
PEB 2055  
PEF 2055  
Application Hints  
+5 V  
+5 V  
1kΩ  
1kΩ  
Quadruple Codec  
Filter Device  
R
R
4 x IOM -2 Ports  
EPIC  
Analog  
Lines  
4096 kHz  
8 kHz  
DCL  
FSC  
DCL  
FSC  
DD0  
DU0  
DD1  
DU1  
DD2  
DU2  
DD3  
DU3  
PFS  
PDC  
R
SICOFI -4  
DIN  
RxD0  
TxD0  
RxD1  
TxD1  
RxD2  
TxD2  
RxD3  
TxD3  
DOUT  
Quadruple Codec  
Filter Device  
PCM  
Interface:  
Not Used  
Analog  
Lines  
2048 kbit/s  
2048 kbit/s  
DCL  
FSC  
R
SICOFI -4  
DIN  
DOUT  
µ
P
Layer-2  
Controller  
DCL  
FSC  
IDP1  
IDP0  
ICC  
Trunk Line  
to Central  
Office  
DCL  
FSC  
DIN  
IEC-Q  
NT-PABX  
Mode  
ISDN  
U
Interface  
k
DOUT  
CLS  
4096 kHz  
PLL  
ITS09555  
Figure 83  
Small PBX with SICOFI®-4 and IEC-Q  
Semiconductor Group  
239  
PEB 2055  
PEF 2055  
Application Hints  
5.9.3  
Miscellaneous  
5.9.3.1 Interfacing the EPIC® to a MUSAC  
The PCM interface of the EPIC can easily be connected to the Multipoint Switching and  
Conferencing circuit MUSAC (PEB 2245) when using the set-up and PCM timing as  
shown in figure 84. This configuration can then for example be used in a PBX to  
implement conferencing functions for up to 21 simultaneous conferences.  
4096 kHz  
8 kHz  
R
EPIC  
MUSAC TM  
DCL  
FSC  
PFS  
PDC  
SP  
IN1  
IN2  
IN3  
IN4  
IN5  
IN6  
IN7  
CLK  
4096 kbit/s  
DD0  
DU0  
DD1  
DU1  
DD2  
DU2  
DD3  
DU3  
RxD0  
TxD0  
RxD1  
TxD1  
RxD2  
TxD2  
RxD3  
TxD3  
OUT0  
IN0  
R
4 x IOM -2 Ports  
PCM Backplane  
4 x 2048 kbit/s  
OUT1  
OUT2  
OUT3  
µ
P
ITS09556  
Figure 84  
Interconnection Example EPIC® - MUSAC  
Semiconductor Group  
240  
 
PEB 2055  
PEF 2055  
Application Hints  
R
MUSAC/EPIC  
SP/PFS  
:
CLK/PDC  
OUT#/TxD#  
IN#/RxD#  
TS63, Bit 0  
TS63, Bit 0  
TS0, Bit 7  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 5  
TS0, Bit 4  
TS0, Bit 4  
TS0, Bit 3  
TS0, Bit 3  
ITT09557  
Figure 85  
Timing Example to Interconnect the EPIC® and the MUSAC on an IOM®-2 Line  
Card  
The following values must be programmed to the PCM and CFI registers of the EPIC  
and to the MOD and CFR registers of the MUSAC to obtain the desired PCM and IOM-2  
timing:  
EPIC®  
PMOD  
= 0100 0100B = 44H PCM mode 1, single rate clock, PFS  
evaluated with falling clock edge, input  
selection RxD0 and RxD3, PCM comparison  
disabled  
PBNR  
POFD  
POFU  
PCSR  
= 1111 1111B = FFH 512 bits (64 ts) per PCM frame  
= 1111 0000B = F0H PFS marks downstream PCM TS0, bit 6  
= 0001 1000B = 18H PFS marks upstream PCM TS0, bit 6  
= 0100 0101B = 45H PCM data received with falling, transmitted  
with rising clock edge  
CMD1  
CMD2  
= 0010 0000B = 20H PDC/PFS clock source, PFS evaluated with  
falling clock edge, prescaler = 1, CFI mode 0  
= 1101 0000B = D0H FC mode 6, double rate clock, CFI data  
transmitted with rising, received with falling  
clock edge  
CBNR  
= 1111 1111B = FFH 256 bits (32 ts) per CFI frame  
Semiconductor Group  
241  
PEB 2055  
PEF 2055  
Application Hints  
CTAR  
CBSR  
= 0000 0010B = 02H PFS marks downstream CFI TS0  
= 0010 0000B = 20H PFS marks downstream CFI bit 6, upstream  
bits not shifted  
CSCR  
= 0000 0000B = 00H 64, 32, 16 kbit/s channels located on CFI bits  
7 … 0, 7 … 4, 7 … 6  
MUSAC  
MOD  
CFR  
= 0100 0100B = 03H input mode 8 × 4M, output mode 4 × 4M  
= 1111 1111B = DEH 4.096 MHz device clock, conferencing  
mode, A-law, even bits inverted  
5.9.3.2 Space and Time Switch for 16 kbit/s Channels  
The EPIC is optimized for the space and time switching of 64 kbit/s channels (8 bit time  
slots). The switching of 32 and 16 kbit/s subchannels is also supported, but these  
channels can only be freely selected at the PCM interface. At the CFI, only one  
subchannel per 8 bit time slot can be switched (see chapter 5.4.2). Usually, this is  
sufficient because on the IOM-2 interface, only one 16 kbit/s D channel per time slot  
needs to be switched. Up to four D channels may then be combined into a single 8 bit  
PCM time slot.  
If a completely flexible space and time switch for contiguous 16 kbit/s channels is  
required, the following method can be used:  
The four CFI ports are connected in parallel as shown in figure 86. Each CFI port is  
programmed via the CFI subchannel register (CSCR) to handle a different 2 bit subtime  
slot position. With this configuration, any mixture of 16, 32 and 64 kbit/s channels may  
be switched between the CFI and the PCM interfaces. Up to 128 16 kbit/s channels per  
direction can be handled by the EPIC. The switching software must select the CFI port  
number according to the required CFI subchannel position for each CFI - PCM  
connection. The PCM subchannel position is selected via the control memory (CM) code  
field (see table 24). For 32 and 64 kbit/s connections, only one CFI port of a given time  
slot may be programmed in order to avoid collisions on the CFI “bus”.  
Semiconductor Group  
242  
PEB 2055  
PEF 2055  
Application Hints  
R
EPIC  
DCL  
FSC  
PFS  
PDC  
DD  
DU  
DD0  
DU0  
DD1  
DU1  
DD2  
DU2  
DD3  
DU3  
RxD0  
TxD0  
RxD1  
TxD1  
RxD2  
TxD2  
RxD3  
TxD3  
128 x 16 kbit/s  
128 x 16 kbit/s  
DD0/DU0  
DD1/DU1  
DD2/DU2  
DD3/DU3  
SC01...00 = 11  
SC11...10 = 10  
SC21...20 = 01  
SC31...30 = 00  
DD/DU  
CSCR = 1B  
H
ITS09558  
Figure 86  
Non-blocking Space and Time Switch for 16 kbit/s Channels  
Semiconductor Group  
243  
PEB 2055  
PEF 2055  
Application Hints  
5.9.3.3 Interfacing an IOM®-2 Terminal Mode Interface to a 2.048 Mbit/s PCM  
Backplane  
For some applications, it is necessary to connect IOM-2 terminal devices (e.g. ARCOFI,  
PSB 2160) to a PCM backplane. In such a configuration, the EPIC can be used as a rate  
adaptor between these two differing data rates. Since the internal prescalers of the EPIC  
cannot be used to convert the 2.048 Mbit/s (PCM) into 768 kbit/s (IOM-2 terminal mode),  
an external clock converting circuit as shown in figure 87 has to be built up. A PLL  
controlled oscillator generates the IOM-2 data clock of 1.536 MHz by comparing the  
PCM clock divided by 4 with the DCL clock divided by 3.  
1.536 MHz  
4
DCL  
FSC  
PLL  
3
EPIC R  
8 kHz  
PFS  
PDC  
FSC  
DCL  
2.048 MHz  
RxD0  
TxD0  
RxD1  
TxD1  
RxD2  
TxD2  
RxD3  
TxD3  
DD0  
DU0  
DD1  
DU1  
DD2  
DU2  
DD3  
DU3  
R
4 x IOM -2 Ports  
(terminal mode)  
2.048 Mbit/s  
768 kbit/s  
4 x  
µ
P
ITS09559  
Figure 87  
Interface Circuit to adapt the IOM®-2 (768 kbit/s) and PCM (2.048 Mbit/s) Data Rates  
Semiconductor Group  
244  
 
PEB 2055  
PEF 2055  
Application Hints  
PFS/FSC  
(8 kHz)  
PDC  
(2.048 MHz)  
TxD#  
(2.048 Mbit/s)  
TS31, Bit 1 TS31,Bit 0 TS0,Bit 7 TS0,Bit 6 TS0,Bit 5 TS0,Bit 4 TS0,Bit 3 TS0,Bit 2 TS0,Bit 1 TS0,Bit 0 TS0,Bit 7 TS0,Bit 6  
RxD#  
(2.048 Mbit/s)  
TS31, Bit 1 TS31,Bit 0 TS0,Bit 7 TS0,Bit 6 TS0,Bit 5 TS0,Bit 4 TS0,Bit 3 TS0,Bit 2 TS0,Bit 1 TS0,Bit 0 TS0,Bit 7 TS0,Bit 6  
DCL  
(1.536 MHz)  
DD#  
(768 kbit/s)  
TS12, Bit 0  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
DU#  
(768 kbit/s)  
TS12, Bit 0  
TS0, Bit 7  
TS0, Bit 6  
TS0, Bit 5  
TS0, Bit 4  
ITT09560  
Figure 88  
IOM®-2 (768 kbit/s) and PCM (2.048 Mbit/s) Timing Example  
If the PCM input clock timing of figure 88 applies, the following values have to be written  
to the EPIC to obtain the correct PCM and CFI timing:  
EPIC®  
PMOD  
= 0010 0000B = 20H PCM mode 0, single rate clock, PFS  
evaluated with rising clock edge,  
PCM comparison disabled  
PBNR  
POFD  
POFU  
PCSR  
= 1111 1111B = FFH 256 bits (32 ts) per PCM frame  
= 1111 0000B = F0H PFS marks downstream PCM TS0, bit 7  
= 0001 1000B = 18H PFS marks upstream PCM TS0, bit 7  
= 0000 0001B = 01H PCM data received with falling, transmitted  
with rising clock edge  
CMD1  
CMD2  
CBNR  
= 1110 0000B = E0H DCL/FSC clock source, FSC evaluated with  
rising clock edge, prescaler = 1, CFI mode 0  
= 0000 0000B = 00H CFI data transmitted with rising, received with  
falling clock edge  
= 0101 1111B = 5FH 96 bits (12 ts) per CFI frame  
CTAR  
CBSR  
= 0000 0010B = 02H PFS marks downstream CFI TS0  
= 0010 0000B = 20H PFS marks downstream CFI bit 7, upstream  
bits not shifted  
CSCR  
= 0000 0000B = 00H 64, 32, 16 kbit/s channels located on CFI bits  
7 … 0, 7 … 4, 7 … 6  
Semiconductor Group  
245  
 
PEB 2055  
PEF 2055  
Electrical Characteristics  
6
Electrical Characteristics  
Absolute Maximum Ratings  
Parameter  
Symbol  
Limit Values  
Unit  
min.  
max.  
Ambient temperature under bias: PEB  
PEF  
TA  
TA  
0
– 40  
70  
85  
°C  
°C  
Storage temperature  
Tstg  
65  
125  
°C  
Voltage on any pin with respect to ground VS  
Maximum voltage on any pin  
0.4  
VDD + 0.4 V  
Vmax  
6
V
Note: Stresses above those listed here may cause permanent damage to the device.  
Exposure to absolute maximum ratings conditions for extended periods may affect  
device reliability.  
Parameter  
Symbol  
Limit Values  
Unit Test Condition  
min.  
max.  
0.8  
L-input voltage  
H-input voltage  
L-output voltage  
VIL  
0.4  
V
VIH  
VOL  
2.2  
VDD + 0.4  
0.45  
V
IOL = 7 mA  
(pins DU3..0,  
DD3..0)  
IOL = 2 mA  
(all other)  
H-output voltage  
H-output voltage  
VOH  
VOH  
2.4  
V
V
IOH = 400 µA  
IOH = 100 µA  
VDD 0.5  
operational ICC  
mA VDD = 5 V,  
Power  
supply  
current  
mA inputs at 0 V or VDD,  
no output loads  
9.5  
6.5  
PDC > 4.096 MHz  
PDC 4.096 MHz  
Input leakage current  
Output leakage current  
ILI  
10  
10  
µA  
µA  
0 V < VIN < VDD to 0 V  
0 V < VOUT < VDD to 0 V  
ILO  
Note: The listed characteristics are ensured over the operating range of the integrated  
circuit. Typical characteristics specify mean values expected over the production  
spread. If not otherwise specified, typical characteristics apply at TA = 25 °C and  
the given supply voltage.  
Semiconductor Group  
246  
PEB 2055  
PEF 2055  
Electrical Characteristics  
Capacitances  
Parameter  
Symbol  
Limit Values  
Unit  
min.  
max.  
10  
Input capacitance  
Output capacitance  
I/O  
CIN  
pF  
pF  
pF  
COUT  
CI/O  
15  
20  
AC Characteristics  
Ambient temperature under bias range, VDD = 5 V ± 5 %.  
Inputs are driven to 2.4 V for a logical “1” and to 0.4 V for a logical “0”.  
Timing measurements are made at 2.0 V for a logical “1” and at 0.8 V for a logical “0”.  
The AC-testing input/output wave forms are shown below.  
2.4 V  
2.0 V  
0.8 V  
2.0 V  
0.8 V  
Device  
Under  
Test  
Test Points  
CL= 150 pF  
0.4 V  
ITS05853  
Figure 89  
I/O-Wave Form for AC-Test  
Semiconductor Group  
247  
PEB 2055  
PEF 2055  
Electrical Characteristics  
Bus Interface Timing  
Parameter  
Symbol  
Limit Values  
max.  
Unit  
min.  
0
R or W set-up to DS  
RD-pulse width  
tDSD  
tRR  
tRI  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
120  
70  
RD-control interval  
Data output delay from RD  
Data float delay from RD  
WR-pulse width  
tRD  
tDF  
tWW  
tWI  
100  
25  
60  
70  
30  
10  
30  
10  
15  
0
WR-control interval  
Data set-up time to WRxCS, DSxCS  
tDW  
Data hold time from WRxCS, DSxCS tWD  
ALE-pulse width  
tAA  
tAL  
Address set-up time to ALE  
Address hold time from ALE  
ALE set-up time to WR, RD  
Address set-up time to WR, RD  
Address hold time from WR  
tLA  
tALS  
tAS  
tAH  
10  
40  
Semiconductor Group  
248  
PEB 2055  
PEF 2055  
Electrical Characteristics  
mP Read Cycle  
t RR  
t WW  
t AA  
t RI  
CS x RD  
t DF  
t RD  
D0-07  
Data  
mP Write Cycle  
t WI  
CS x WR  
t DW  
t WD  
D0-07  
Data  
Address Timing,  
Multiplexed Bus Mode  
ALE  
CS x WR  
CS x RD  
t AL  
t ALS  
t LA  
Address  
AD0 - AD7  
ITT09561  
Figure 90  
Siemens/Intel Bus Mode  
Semiconductor Group  
249  
PEB 2055  
PEF 2055  
Electrical Characteristics  
Address Timing,  
Demultiplexed Bus Mode  
CS x WR  
CS x RD  
t AS  
t AH  
A0 - A3  
Address  
ITT09562  
Figure 91  
Siemens/Intel Bus Mode  
Semiconductor Group  
250  
PEB 2055  
PEF 2055  
Electrical Characteristics  
mP Read Cycle  
R/ W  
t DSD  
t RR  
t RI  
CS x DS  
D0 - D7  
t RD  
t DF  
Data  
mP Write Cycle  
R/W  
t DSD  
t WW  
t WI  
CS x DS  
D0 - D7  
t DW  
t WD  
Data  
Address Timing  
CS x DS  
t AS  
t AH  
Address  
A0 - A3  
ITT09563  
Figure 92  
Motorola Bus Mode  
Semiconductor Group  
251  
PEB 2055  
PEF 2055  
Electrical Characteristics  
PCM and Configurable Interface Timing  
Parameter  
Symbol Limit Values Unit Test Condition  
min. max.  
Clock period  
tCP  
240  
80  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
Clock frequency  
4096 kHz  
Clock period low  
Clock period high  
Clock period  
tCPL  
tCPH  
tCP  
100  
120  
50  
Clock frequency  
> 4096 kHz  
Clock period low  
Clock period high  
Frame set-up time to clock  
Frame hold time from clock  
Data clock delay  
tCPL  
tCPH  
tFS  
50  
25  
tFH  
50  
2)  
tDCD  
125  
Serial data input set-up time tS  
7
(falling clock edge)  
PCM-input data  
frequency > 4096 kbit/s  
Serial data input set-up time tS  
(rising clock edge)  
15  
ns  
Serial data hold time  
Serial data input set-up time tS  
Serial data hold time  
Serial data input set-up time tS  
Serial data hold time  
Serial data input set-up time tS  
Serial data hold time  
PCM-serial data output delay tD  
tH  
tH  
tH  
tH  
35  
15  
55  
20  
50  
0
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
PCM-input data  
frequency 4096 kbit/s  
CFI-input data  
frequency > 4096 kbit/s  
CFI-input data  
frequency 4096 kbit/s  
75  
55  
60  
65  
1)  
1)  
Tristate control delay  
tT  
CFI-serial data output delay  
CFI-serial data output delay  
tCDF  
tCDR  
Falling clock edge 2)  
Rising clock edge 2)  
90  
1) Parameter can be estimated to: 20 ns + 0.25 ns x [C ]  
L
2) The max. difference between TDCD and TCDF / TCDR is 60 ns / 35 ns  
Semiconductor Group  
252  
PEB 2055  
PEF 2055  
Electrical Characteristics  
t CP  
t CPH  
t CPL  
PDC/DCL  
t FH  
tFH  
PFS  
t FS  
t FS  
(PMOD : PSM = 0; CMD1 : CSS = 0)  
FSC  
(CMD1 : CSS, CSM = 1,0)  
t FS  
t FH  
t FH  
PFS  
(PMOD : PSM = 1; CMD1 : CSS = 0)  
FSC  
(CMD1 : CSS, CSM = 1,1)  
t FS  
tCDF  
1st Bit of Frame  
2ndBit of Frame  
3rd Bit of Frame  
DD (CMD2 : CXF = 0)  
tCDR  
tH  
1st Bit of Frame  
DU (CMD2 : CRR = 0)  
tS  
1st Bit of Frame  
DD (CMD2 : CXF = 1)  
DU (CMD2 : CRR = 1)  
tCDF  
t H  
1st Bit of Frame  
tCDR  
t S  
1st Bit of Frame  
t S  
DD (CMD2 : CXF = 0)  
DU (CMD2 : CRR = 0)  
DD (CMD2 : CXF = 1)  
1st Bit of Frame  
tCDF  
t H  
1st Bit of Frame  
t S  
1st Bit of Frame  
DU (CMD2 : CRR = 1)  
DD (CMD2 : CXF = 1)  
tCDF  
t H  
1st Bit of Frame  
Last Bit of the Frame  
tH  
Last Bit of Frame  
tS  
DU (CMD2 : CRR = 0)  
DD (CMD2 : CXF = 0)  
tCDR  
1st Bit of Frame  
tDCD  
tDCD  
DCL  
(CMD1 = 0x1000xx)  
tDCD  
(CMD2 : DOC = 1)  
FSC  
ITD05868  
(CMD2 : FC (2 : 0) = 011)  
Figure 93  
Configurable Interface Timing, CMD:CSP1,0 = 10 (prescaler divisor = 1)  
Semiconductor Group  
253  
PEB 2055  
PEF 2055  
Electrical Characteristics  
t CP  
t CPH  
PDC/DCL  
t FH  
tCPL  
t FS  
PFS  
t FS  
(PMOD : PSM = 0; CMD1 : CSS = 0)  
FSC  
(CMD1 : CSS, CSM = 1,0)  
t FH  
t FH  
PFS  
(PMOD : PSM = 1; CMD1 : CSS = 0)  
FSC  
t FS  
t FS  
(CMD : CSS, CSM = 1,1)  
t FH  
tDF  
1st Bit of Frame  
2ndBit of Frame  
3rd Bit of Frame  
DD (CMD2 : CXF = 0)  
DU (CMD2 : CRR = 0)  
tH  
1st Bit of Frame  
tS  
1st Bit of Frame  
DD (CMD2 : CXF = 1)  
DU (CMD2 : CRR = 1)  
tDF  
t H  
1st Bit of Frame  
tDR  
t S  
1st Bit of Frame  
t S  
DD (CMD2 : CXF = 0)  
DU (CMD2 : CRR = 0)  
DD (CMD2 : CXF = 1)  
1st Bit of Frame  
t DF  
t H  
1st Bit of Frame  
t S  
1st Bit of Frame  
DU (CMD2 : CRR = 1)  
DD (CMD2 : CXF = 1)  
t DF  
t H  
1st Bit of Frame  
Last Bit of the Frame  
tH  
Last Bit of Frame  
tS  
DU (CMD2 : CRR = 0)  
DD (CMD2 : CXF = 0)  
tDR  
1st Bit of Frame  
tDCD  
tDCD  
DCL  
(CMD1 = 0x1000xx)  
tDCD  
(CMD2 : COC = 1)  
FSC  
ITD05869  
Figure 94  
Configurable Interface Timing, CMD:CSP1,0 = 01 (prescaler divisor = 1,5)  
Semiconductor Group  
254  
PEB 2055  
PEF 2055  
Electrical Characteristics  
t FS  
t CP  
PDC/DCL  
t CPH  
t FS  
t CPL  
tFH  
PFS  
(PMOD : PSM = 0; CMD1 : CSS = 0)  
FSC  
(CMD1 : CSS, CSM = 1,0)  
t FH  
t FH  
PFS  
(PMO D : PSM = 1; CMD1 : CSS = 0)  
FSC  
(CMD1 : CSS, CSM = 1,1)  
t FH  
t FS  
t DR  
1st Bit of Frame  
2ndBit of Frame  
3rd Bit of Frame  
DD (CMD2 : CXF = 0)  
tFS  
tCR  
tH  
1st Bit of Frame  
DU (CMD2 : CRR = 0)  
tS  
1st Bit of Frame  
DD (CMD2 : CXF = 1)  
DU (CMD2 : CRR = 1)  
t DR  
t H  
1st Bit of Frame  
tDR  
t S  
1st Bit of Frame  
t S  
DD (CMD2 : CXF = 0)  
DU (CMD2 : CRR = 0)  
DD (CMD2 : CXF = 1)  
1st Bit of Frame  
tDR  
t H  
1st Bit of Frame  
t S  
1st Bit of Frame  
DU (CMD2 : CRR = 1)  
DD (CMD2 : CXF = 1)  
tDR  
t H  
Last Bit of the Frame  
1st Bit of Frame  
tH  
Last Bit of Frame  
tS  
DU (CMD2 : CRR = 0)  
DD (CMD2 : CXF = 0)  
t DR  
1st Bit of Frame  
tDCD  
tDCD  
DCL  
(CMD1 = 0x1000xx)  
tDCD  
COC = 1  
FSC  
ITD05870  
Figure 95  
Configurable Interface Timing, CMD:CSP1,0 = 00 (prescaler divisor = 2)  
Semiconductor Group  
255  
PEB 2055  
PEF 2055  
Electrical Characteristics  
t CP  
t CPH  
t CPL  
PDC  
t FH  
tFH  
t FS  
t FS  
PFS (PMOD : PSM = 0)  
PFS (PMOD : PSM = 1)  
TxD (PCSR : URE = 1)  
TSC (PCSR : URE = 1)  
RxD (PCSR : ’DRE’ = 0)  
TxD (PCSR : URE = 0)  
TSC (PCSR : URE = 0)  
t FS  
t FH  
t FH  
t FS  
t D  
1st Bit of Frame  
2nd Bit of Frame  
3rd Bit of Frame  
t T  
1st Bit of Frame  
tH  
1st Bit of Frame  
tS  
1st Bit of Frame  
tD  
tT  
t H  
RxD (PCSR : ’DRE’ = 1)  
TxD (PCSR : URE = 1)  
TSC (PCSR : URE = 1)  
RxD (PCSR : ’DRE’ = 0)  
TxD (PCSR : URE = 0)  
TSC (PCSR : URE = 0)  
RxD (PCSR : ’DRE’ = 1)  
1st Bit of Frame  
tD  
t S  
1st Bit of Frame  
tT  
1st Bit of Frame  
t S  
1st Bit of Frame  
t H  
t D  
1st Bit of Frame  
t T  
1st Bit of Frame  
t S  
1st Bit of Frame  
t H  
ITD05871  
Figure 96  
PCM-Interface Timing  
Semiconductor Group  
256  
PEB 2055  
PEF 2055  
Package Outlines  
7
Package Outlines  
P-LCC-44-1  
(Plastic Leaded Chip Carrier)  
Sorts of Packing  
Package outlines for tubes, trays etc. are contained in our  
Data Book "Package Information"  
Dimensions in mm  
SMD = Surface Mounted Device  
Semiconductor Group  
257  
PEB 2055  
PEF 2055  
Appendix  
8
Appendix  
8.1  
Working Sheets  
The following pages contain some working sheets to facilitate the programming of the  
EPIC. For several tasks (i.e. initialization, time slot switching, ...) the corresponding  
registers are summarized in a way the programmer gets a quick overview on the  
registers he has to use.  
8.1.1  
Register Summary for EPIC® Initialization  
PCM Interface  
PMOD PCM Mode Register  
PMD PCR  
RW, 20 (0 + RBS = 1), reset-val.=00  
H
H
PSM  
AIS  
AIC  
PMD0..1 = PCM Mode, 00 = 0, 01 = 1, 10 = 2  
PCR = PCM Clock Rate:  
0 = equal to PCM data rate  
1 = double PCM data rate (not for mode 2)  
PSM = PCM Synchron Mode:  
0 = frame synchr. with falling edge,  
1 = rising edge of PDC  
AIS0..1 = Alternative Input Section: (PCM mode dependent)  
Mode 0:  
Mode 1:  
AIS = 0  
AIS0 = 0: RXD1 = IN0, AIS0 = 1: RXD0 = IN0  
AIS1 = 0: RXD3 = IN1, AIS1 = 1: RXD2 = IN1  
AIS0 = 0  
Mode 2:  
AIS1 = 0: RXD3 = IN, AIS = 1: RXD2 = IN  
AIC0..1 = Alternative Input Comparison: (PCM mode dependent)  
Mode 0, 1: AIC0 = 0: no comparison, AIC0 = 1: RXD0 == RXD1  
AIC1 = 0: no comparison, AIC1 = 1: RXD2 == RXD3  
Mode 2:  
AIC0 = 0:  
AIC1 = 0: no comparison, AIC1 = 1: RXD2 == RXD3  
PBNR  
PCM Bit Number Register  
RW, 22 (1 + RBS = 1), reset-val.=FF  
H H  
BNR  
BNR0..7 = Bit Number per Frame (mode dependent)  
Mode 0: BNR = number of bits – 1  
Mode 1: BNR = (number of bits)/2 – 1  
Mode 2: BNR = (number of bits)/4 – 1  
Figure 97  
EPIC® Initialization Register Summary (working sheet)  
Semiconductor Group  
258  
PEB 2055  
PEF 2055  
Appendix  
POFD  
PCM Offset Downstream Register RW, 24 (2 + RBS = 1), reset-val. = 0  
H H  
OFD9..2  
OFD2..9 = Offset Downstream (see PCSR for OFD0..1)  
Mode 0: (BND – 17 + BPF) mod BPF --> OFD2..9  
Mode 1: (BND – 33 + BPF) mod BPF --> OFD1..9  
Mode 2: (BND – 65 + BPF) mod BPF --> OFD0..9  
BND = number of bits + 1 that the downstream frame start is left shifted relative to the  
frame sync  
BPF = number of bits per frame  
Unused bits must be set to 0 !  
POFU  
PCM Offset Upstream Register  
RW, 26 (3 + RBS = 1), reset-val. = 0  
H H  
OFU9..2  
OFU2..9 = Offset Upstream (see PCSR for OFU0..1)  
Mode 0: (BND + 23 + BPF) mod BPF --> OFU2..9  
Mode 1: (BND + 47 + BPF) mod BPF --> OFU1..9  
Mode 2: (BND + 95 + BPF) mod BPF --> OFU0..9  
BND = number of bits + 1 that the upstream frame is left shifted relative to the frame start  
BPF = number of bits per frame  
Unused bits must be set to 0 !  
PCSR  
PCM Clock Shift Register  
OFD1..0 DRE  
RW, 28 (4 + RBS = 1), reset-val. = 0  
H H  
0
0
OFU1..0  
URE  
OFD0..1 = Offset Downstream (see POFD)  
DRE = Downstream Rising Edge,  
0 = receive data on falling edge,  
1 = receive data on rising edge  
OFU0..1 = Offset Upstream (see POFU)  
URE = Upstream Rising Edge,  
0 = send data on falling edge,  
1 = send data on rising edge  
Figure 98  
EPIC® Initialization Register Summary (working sheet)  
Semiconductor Group  
259  
PEB 2055  
PEF 2055  
Appendix  
CFI Interface  
CMD1 CFI Mode Register 1  
CSS CSM CSP1..0  
CSS = Clock Source Select,  
RW, 2C (6 + RBS = 1), reset-val.=00  
H
H
CMD1..0  
CIS1..0  
0 = PDC/PFS used for CFI,  
1= DCL/FSC are inputs  
CSM = CFI Synchronization Mode:  
1 = frame syncr. with rising edge,  
0 = falling edge of DCL  
if CSS = 0 ==> CMD1:CSM = PMOD:PSM !  
CSP0..1 = Clock Source Prescaler: 00 = 1/2, 01 = 1/1.5, 10 = 1/1  
CMD0..1 = CFI Mode: 00 = 0, 01 = 1, 10 = 2, 11 = 3  
CIS0..1 = CFI Alternative Input Section  
Mode 0, 3: CIS0..1 = 0  
Mode 1, 2: CIS0: 0 = IN0 = DU0, 1 = IN0 = DU2  
Mode 1: CIS1: 0 = IN1 = DU1, 1 = IN1 = DU3  
CMD2  
CFI Mode Register 2  
RW, 2E (7 + RBS = 1), reset-val.=00  
H
H
FC2..0  
COC  
CXF  
CRR  
CBN9..8  
For IOM®-2 CMD2 can be set to D0  
H
FC0..2 = Framing Signal Output Control (CMD1:CSS = 0)  
= 010 suitable for PBC, = 011 for IOM-2, = 110 IOM-2 and SLD  
COC = Clock Output Control (CMD1:CSS = 0)  
= 0 DCL = data rate,  
= 1 DCL 2 × data rate (only mode 0 and 3 !)  
CXF = CFI Transmit on Falling Edge: 0 = send on rising edge, 1 = send on falling DCL edge  
CRR = CFI Receive on Rising Edge: 0 = receive on falling edge, 1 = send on rising DCL  
edge  
CBN8..9 = CFI Bit Number (see CBNR)  
CBNR  
CFI Bit Number Register  
RW, 30 (8 + RBS = 1), reset-val.=FF  
H H  
CBN  
CBN0..7 = CFI Bit Number per Frame – 1 (see CMD2:CBN8..9)  
Figure 99  
EPIC® Initialization Register Summary (working sheet)  
Semiconductor Group  
260  
PEB 2055  
PEF 2055  
Appendix  
CTAR  
CFI Time Slot Adjustment Register RW, 32 (9 + RBS = 1), reset-val.=00  
H H  
0
TSN  
TSN0..6 = (number of time slots + 2) the DU and DD frame is left shifted relative to frame  
start (see also CBSR)  
CBSR  
CFI Bit Shift Register  
CDS2..0  
RW, 34 (A + RBS = 1), reset-val.=00  
H H  
0
CUS3..0  
CDS2..0: CFI Downstream/Upstream Bit Shift  
Shift DU and DD frame:  
000 = 2 bits right  
001 = 1 bit right  
010 = 6 bits left  
011 = 5 bits left  
100 = 4 bits left  
101 = 3 bits left  
110 = 2 bits left  
111 = 1 bit left  
Relative to PFS (if CMD1:CSS = 0)  
Relative to FSC (if CMD1:CSS = 1)  
CSCR  
CFI Subchannel Register  
CS3 CS2  
RW, 36 (A + RBS = 1), reset-val.=00  
H
H
CS1  
CS0  
SC3 0..1 control port 3 (+ port 7 for CFI mode 3 (SLD))  
SC2 0..1 control port 2 (+ port 6 for CFI mode 3 (SLD))  
SC1 0..1 control port 1 (+ port 5 for CFI mode 3 (SLD))  
SC0 0..1 control port 0 (+ port 4 for CFI mode 3 (SLD))  
for 64 kBit/s channel: 00/01/10/11 = bits 7..0  
for 32 kBit/s channel: 00/10 = bits 7..4,  
01/11 = bits 3..0  
Figure 100  
EPIC® Initialization Register Summary (working sheet)  
Semiconductor Group  
261  
PEB 2055  
PEF 2055  
Appendix  
8.1.2  
Switching of PCM Time Slots to the CFI Interface (data downstream)  
ELIC,R EPIC R  
Loop  
Loop  
1
0
CFI TS  
PCM TS  
Data Memory  
Output  
Disable  
Direct µP Access  
Switching of 8 Bit Channels:  
.
For MADR/MAAR setings see loewr box  
CFI Port, TS  
PCM Port, TS  
Switching Command  
MAAR  
0
.
.
.
.
.
.
.
MADR  
MADR  
.
.
.
.
.
.
.
.
.
.
.
.
MACR  
MACR  
0
1
1
1
0
0
0
1
Switching of Subchannels:  
.
For MADR/MAAR setings see loewr box  
CFI Port, TS  
PCM Port, TS  
Switching Command  
MAAR  
CSCR  
0
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
0
1
1
1
.
.
.
.
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
1
0
1
0
1
0
=
=
=
=
=
=
7 ... 4  
3 ... 0  
7, 6  
5, 4  
3, 2  
3
2
1
0
CFI Port  
Switched  
TS Width  
and PCM  
Bit Position  
0
0
1
1
0
1
0
1
=
=
=
=
7 ... 4 or 7, 6 (default for D channel)  
3 ... 0 or 5, 4  
7 ... 4 or 3, 2  
1, 0  
CFI Bit Position  
3 ... 0 or 1, 0  
Writing 8 Bit CFI Idle Codes by the mP :  
CFI Port, TS  
Value of Idle Code (W)  
Write Value to CM Data  
MAAR  
0
.
.
.
.
.
.
.
MADR  
.
.
.
.
.
.
.
.
MACR  
0
1
1
1
1
0
0
1
Reading back a previously written 8  
Bit CFI Idle Codes by the mP :  
.
For MAAR setings see lower box  
CFI Port, TS  
Select µP Access  
MAAR  
MAAR  
0
.
.
.
.
.
.
.
.
.
.
.
MACR  
MACR  
0
1
1
1
1
0
0
0
1
0
PCM Port, TS  
Value of Idle Code (R)  
Read Value to CM Data  
0
.
.
.
MADR  
MADR  
.
.
.
.
.
.
.
.
.
.
1
1
0
0
1
0
Reading PCM Data switched to CFI:  
PCM Port, TS  
Value (R)  
Read Data Memory:  
MAAR  
0
.
.
.
.
.
.
.
.
.
.
.
.
.
MACR  
1
.
.
.
.
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
1
1
1
0
0
1
1
0
1
0
1
0
=
7 ... 0  
7 ... 4  
3 ... 0  
7, 6  
5, 4  
3, 2  
=
=
=
=
=
=
Desired  
TS Width  
and Bit  
Position  
1, 0  
Tristating a CFI Output TS:  
CFI Port, TS  
Select µP Access  
MAAR  
0
.
.
.
.
.
.
.
.
.
.
MACR  
0
1
1
1
0
0
0
0
CFI + PCM Mode 0  
PCM Mode 1  
CFI Mode 1  
CFI + PCM Mode 2  
Port  
.
Port  
.
Port  
.
MADR  
MAAR  
MADR  
MAAR  
MADR  
MAAR  
X
.
.
.
X
.
.
.
.
.
.
X
.
.
.
.
.
.
X
.
.
.
.
.
.
.
TS  
TS  
TS  
TS  
ITD08110  
Figure 101  
Switching of PCM Time Slots to the CFI Interface (working sheet)  
Semiconductor Group  
262  
PEB 2055  
PEF 2055  
Appendix  
8.1.3  
Switching of CFI Time Slots to the PCM Interface (data upstream)  
ELIC,R EPIC R  
1
0
CFI TS  
PCM TS  
Data Memory  
Loop  
Enable/  
Disable  
Loop  
Direct µP Access  
Switching of 8 BIt Channels:  
.
For MADR/MAAR setings see loewr box  
CFI Port, TS  
PCM Port, TS  
Switching Command  
MAAR  
1
.
.
.
.
.
.
.
MADR  
MADR  
.
.
.
.
.
.
.
.
.
.
.
.
MACR  
MACR  
0
1
1
1
0
0
0
1
Switching of Subchannels:  
.
For MADR/MAAR setings see loewr box  
CFI Port, TS  
PCM Port, TS  
Switching Command  
MAAR  
CSCR  
1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
0
1
1
1
.
.
.
.
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
1
0
1
0
1
0
= 7 ... 4  
= 3 ... 0  
= 7, 6  
= 5, 4  
= 3, 2  
= 1, 0  
3
2
1
0
CFI Port  
Switched  
TS Width  
and PCM  
Bit Position  
0
0
1
1
0
1
0
1
= 7 ... 4 or 7, 6 (default for D channel)  
= 3 ... 0 or 5, 4  
= 7 ... 4 or 3, 2  
CFI Bit Position  
= 3 ... 0 or 1, 0  
Enable/Tristate PCM Output TS:  
.
For MAAR setings see lower box  
PCM Port, TS  
Select Bit Position  
Command  
MAAR  
1
.
.
.
.
.
.
.
MADR  
0 = Tristate  
1 = Driver enabled  
Writing/Reading back PCM Idle Codes and reading switched CFI Data:  
1
1
1
1
.
.
.
.
MACR  
0
.
.
.
.
0
0
0
7, 6  
3, 2  
1
1
1
1
0
0
0 = One TS  
1 = All TS  
4, 5  
1, 0  
Neccessary only  
for writing idle  
codes, if a  
connection to  
PCM TS already  
exists!  
CFI Port, TS  
PCM Port, TS  
Disable Switching Connection  
MAAR  
MAAR  
1
.
.
.
.
.
.
.
.
.
.
.
MADR  
MADR  
1
.
.
.
.
.
.
.
.
.
.
MACR  
MACR  
0
1
1
1
0
0
0
0
PCM Port, TS  
Value or Idle Code  
Read/Write Data Memory  
1
.
.
.
.
.
.
.
.
.
.
.
.
.
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
1
1
1
0
0
1
1
0
1
0
1
0
= 7 ... 0  
= 7 ... 4  
= 3 ... 0  
= 7, 6  
= 5, 4  
= 3, 2  
Desired  
TS Width  
and Bit  
1 = Read CFI Value  
Read Back Idle Code  
0 = Write Idle Code  
Position  
= 1, 0  
Reading a CFI TS by the mP (no connection to PCM):  
.
For MAAR setings see lower box  
CFI Port, TS  
Select µP Access  
MAAR  
MAAR  
1
.
.
.
.
.
.
.
.
.
.
.
.
MACR  
0
1
1
1
1
0
0
0
1
0
CFI Port, TS  
TS Value (R)  
Read Value to CM Data  
1
.
.
MADR  
.
.
.
.
.
.
.
.
MACR  
1
1
0
0
1
0
CFI + PCM Mode 0  
PCM Mode 1  
CFI Mode 1  
CFI + PCM Mode 2  
Port  
.
Port  
.
Port  
.
MADR  
MAAR  
MADR  
MAAR  
MADR  
MAAR  
X
.
.
.
.
.
.
X
.
.
.
.
.
.
X
.
.
.
.
.
.
X
.
.
.
.
.
.
.
TS  
TS  
TS  
TS  
ITD08111  
Figure 102  
Switching of CFI Time Slots to the PCM Interface (working sheet)  
Semiconductor Group  
263  
PEB 2055  
PEF 2055  
Appendix  
8.1.4  
Preparing EPIC®s C/I Channels  
ELIC,R EPIC R  
CFI Mode 0  
D
PCM TS  
Data Memory  
R
IOM -2  
C/I  
Pointer  
C/I-FIFO  
CM Data  
Initialization of the C/I Channels Data Downstream:  
R
IOM -2 Channel  
C/I Idle Code  
Mode Selection  
MAAR  
0
.
.
.
1
.
.
0
MADR  
.
.
.
.
.
.
1
1
MACR  
0
1
1
1
.
.
.
.
Port  
1
0
0
0
= Decentral  
D Channel Handling  
1
1
4 Bit C/I  
1
0
1
0
= Central  
6 Bit C/I  
D Channel Handling  
= 6 Bits Analog C/I  
1
1
0
0
1
1
0
0
= ELIC R SACCO-A  
D Channel Handling  
R
IOM -2 Channel  
PCM Port, TS  
Mode Selection  
MAAR  
0
.
.
.
1
.
.
1
MADR  
0
.
.
.
.
.
.
.
MACR  
0
1
1
1
.
.
.
.
Port  
Only for central  
D Channel Handling !  
1
0
1
1 = Decentral  
D Channel Handling  
X = Central  
D Channel Handling  
1 = PCM TS Bit 7, 6  
= PCM TS Bit 5, 4  
1 = PCM TS Bit 3, 2  
= PCM TS Bit 1, 0  
0
1
X
1
1
0
0
1
0
0
1
1
0
0
1 = Analog C/I  
1
1 = ELIC R SACCO-A  
Initialization of the C/I Channels Data Upstream:  
R
IOM -2 Channel  
C/I Idle Code  
Mode Selection  
MAAR  
1
.
.
.
1
.
.
0
MADR  
.
.
.
.
.
.
1
1
MACR  
0
1
1
1
.
.
.
.
Port  
1
0
0
0
= Decentral  
D Channel Handling  
Expected C/I-Value  
1
0
0
0
= Central  
D Channel Handling  
1
1
0
0
1
0
0
0
= 6 Bit Analog C/I  
= ELIC R SACCO-A  
D Channel Handling  
R
IOM -2 Channel  
PCM Port, TS  
Mode Selection  
MAAR  
1
.
.
.
1
.
.
1
MADR  
MADR  
1
.
.
.
.
.
.
.
MACR  
0
1
1
1
.
.
.
.
Port  
Only for central  
D Channel Handling !  
0
0
0
0
= Decentral  
D Channel Handling  
0
1
X
X = Central  
D Channel Handling  
1 = PCM TS Bit 7, 6  
= PCM TS Bit 5, 4  
1 = PCM TS Bit 3, 2  
Expectend C/I Value  
.
.
.
.
.
.
1
1
1
1
0
0
1
0
Only analog  
6 Bit C/I Handling !  
0
0
= PCM TS Bit 1, 0  
= Analog C/I  
1
0
0
0
0
0
= ELIC R SACCO-A  
D Channel Handling  
ITD08112  
Figure 103  
Preparing EPIC®s C/I Channels (working sheet)  
Semiconductor Group  
264  
PEB 2055  
PEF 2055  
Appendix  
8.1.5  
Receiving and Transmitting IOM®-2 C/I-Codes  
ELIC,R EPIC R  
CFI Mode 0  
D
PCM TS  
Data Memory  
IOM R -2  
C/I  
Pointer  
C/I-FIFO  
CM Data  
Transmitting a C/I Code on IOM R -2 Data Downstream:  
IOM R -2 Channel  
C/I Value (W)  
Write Command  
MAAR  
0
.
.
.
1
.
.
0
MADR  
.
.
.
.
.
.
1
1
MACR 0  
1
0
0
1
0
0
0
Port  
1
1
4 Bit C/I  
6 Bit C/I Value  
Receiving a C/I Code on IOM R -2 Data Upstream:  
C/I change detected  
Interrupt : ISTA : SFI  
C/I-FIFO  
1. ...  
B1 B2  
M
C/I  
B1 B2  
M
C/I  
IOM R -2 Frame  
2. ...  
3. ...  
IOM R -2 Channel  
Read CFIFO and copy value to MAAR  
C/I FIFO  
C/I Value (R)  
Read Command  
MAAR  
1
.
.
.
1
.
.
MADR  
.
.
.
.
.
.
1
1
MACR  
1
1
0
0
1
0
0
0
Port  
4 Bit C/I Value  
6 Bit C/I Value  
IOM R -2 Channel  
4 Bit C/I Value : 0  
6 Bit C/I Value : 1  
ITD08113  
Figure 104  
Receiving and Transmitting IOM®-2 C/I-Codes (working sheet)  
Semiconductor Group  
265  
PEB 2055  
PEF 2055  
Appendix  
8.2  
Development Tools  
The SIPB 5000 system can be used as a platform for all development steps. In a later  
stage it is of course necessary to make a cost optimized design. For this, a subset of the  
board design can be used. All the wiring diagrams are shipped with the board to speed  
up this process.  
Siemens offers a very convenient menu driven testing and debugging software. The  
package that is delivered with the user board, allows a direct access to the chip registers  
using symbolic names. Subsequent access may be written to a file and run as a track  
file. Example track files are delivered in the package and will be a great help to the user.  
8.2.1  
SIPB 5000 Mainboard  
Description  
Part Number  
Ordering Code  
SIPB Mainboard  
SIPB 5000  
Q67100-H8647  
AMC 3  
AMC 2  
AMC 1  
80C188 CPU  
System  
Dual Port  
RAM  
PC  
Interface  
ITB05758  
Figure 105  
SIPB_5000 Mainboard  
The SIPB 5000 Mainboard is the general backbone of the SIPB 5XXX user board  
system. It is designed as a standard PC interface card, and it contains basically a  
80C188 CPU system with 7 interfaces. The interface to the PC is realized both as a Dual  
Port Ram and as an additional DMA interface. Up to three daughter modules (see dotted  
blocks) can be added to the Mainboard. They typically carry the components under  
evaluation. The interfaces which are accessible from the back side of the PC have a  
connection to the daughter modules as well. This is to allow access to the components  
under evaluation while the complete board system is hidden inside the PC.  
Semiconductor Group  
266  
PEB 2055  
PEF 2055  
Appendix  
8.2.2  
SIPB 5121 IOM®-2 Line Card (EPIC®/IDEC®)  
Description  
Part Number  
Ordering Code  
IOM-2 Line Card Module  
SIPB 5121  
Q67100-H8656  
R
R
SLD / IOM /PCM  
PCM  
EPIC  
SAC  
AMC  
AMC  
PEB 2055  
R
R
IDEC  
IDEC  
PEB 2075  
HSCX  
SAB 82525  
PEB 2075  
ITB05759  
Figure 106  
SIPB 5121 IOM®-2 Line Card (EPIC®/IDEC®)  
The Line Card Module SIBP 5121 is designed to be used with the ISDN User Board  
SIPB 5000. It serves as an evaluation tool for various line card architectures using the  
Enhanced PCM Interface Controller EPIC PEB 2055.  
Some possible applications are e.g.:  
– Centralized / decentralized D-channel handling of signaling and packet data  
– Emulation of a PABX with primary rate module SIPB 7200  
– Emulation of a small PABX using two line cards  
– Emulation of a digital or analog line card using appropriate layer-1 and/or CODEC  
filter modules  
Semiconductor Group  
267  
PEB 2055  
PEF 2055  
Appendix  
8.2.3  
EPIC® Configurator  
Figure 107  
EPIC® Configuration Tool: Screen Shot  
The EPIC Configurator is an expert system which helps to initialize the IOM-2  
controllers:  
• PEB 2015 (MICO)  
• PEB 2054 (EPIC-S)  
• PEB 2055 (EPIC-1)  
• PEB 2055 (ELIC) (only functional units: EPIC, SACCO-A + arbiter)  
A menu driven software allows the user to define the system requirements on a  
functional level.  
The Configurator then generates a programming sequence in C code for initializing the  
EPIC, providing all required register values.  
Semiconductor Group  
268  
PEB 2055  
PEF 2055  
Lists  
9
Lists  
9.1  
Glossary  
ARCOFI® Audio ringing codec filter  
BPF  
CFI  
Bits per PCM frame  
Configurable interface  
CM  
Control memory  
CO  
Central office  
DCL  
EPIC®  
ETSI  
FIFO  
FSC  
HDLC  
IC  
Data clock  
Extended PCM interface controller  
European telecommunication standards institute  
First-in first-out (memory)  
Frame synchronisation clock  
High-level data link control  
Integrated circuit  
ID  
Identifier  
IOM®  
ISAC®-P  
ISDN oriented modular  
ISDN subscriber access controller on U-interface  
OCTAT®-P Octal transceiver for UPN-interfaces  
PBC  
PBX  
PCM  
PDC  
PFS  
TE  
Peripheral bus controller  
Private branch exchange  
Pulse code modulation  
PCM interface data clock  
PCM interface frame synchronisation  
Terminal equipment  
UPN  
U-interface in private network (PBX)  
Semiconductor Group  
269  

相关型号:

PEB2075-N

ISDN, Other/Special/Miscellaneous
ETC

PEB2075-P

ISDN, Other/Special/Miscellaneous
ETC

PEB2075A1P

Telecom IC, CMOS, PDIP28,
INFINEON

PEB2075C

Telecom IC, CMOS, CDIP28,
INFINEON

PEB2075N

?ISDN D-Channel Exchange Controller?
ETC

PEB2075P

?ISDN D-Channel Exchange Controller?
ETC

PEB2075W

Telecom IC, CMOS, PQCC28,
INFINEON

PEB2080

S/T Bus Interface Circuit(SBC)
INFINEON

PEB2080-C

ISDN Line Interface
ETC

PEB2080-N

S/T Bus Interface Circuit(SBC)
INFINEON

PEB2080-P

S/T Bus Interface Circuit(SBC)
INFINEON

PEB2081

*Transformer Selection Guide for Siemens Telecom ICs - (5/96)
ETC