FC-5C  
FIVE ZONE PANEL  
Conventional Fire Alarm Control  
Description  
The FC-5C Fire Alarm Control panel is a proven, versatile,  
modular control with integral communicator and remote-  
site Upload/Download capability. It meets the require-  
ments of NFPA Standard 72 for Central Station, Protected  
Premises, and Remote (DACT) Supervising Station Fire  
Alarm Systems. It is Listed to UL Standard 864, inherently  
power limited and meets all UL transient immunity require-  
ments.  
The integral communicator includes a wide range of se-  
lectable transmission formats to communicate to virtually  
all central stations. Other features of the communicator  
are: A line-active indicator for each of two phone lines,  
“Kiss-Off’ signal LED, dual ”low telephone voltage detect"  
circuitry, programmable event codes per format and se-  
lectable/deselectable transmission of 62 events. In addi-  
tion, five zones may be configured to five channels as a  
slave communicator with auto-resettable channels for use  
with UL Listed control panels.  
FC-5C  
Features  
Inherently power-limited.  
Integral digital communicator.  
Selectable transmission formats.  
Fire drill function.  
Multiple security techniques allow uploading or download-  
ing within one minute without affecting normal fire panel  
functions. Key system information that can be uploaded  
are: Current System Status, History, Walk Test Files and  
System Programming.  
Integral voltmeter.  
Fully programmable via integral keypad.  
Auto-reset supervisory operation.  
Temporal pattern output per ANSI S3.41.  
Single person walk test.  
An integral voltmeter allows voltage measurements for  
Zone, AC line, NAC 1, NAC2, resettable power and bat-  
tery.  
Alarm verification.  
Real-time clock/calendar.  
32-Event History with time and date stamp.  
Zone disable feature via software.  
Plug-in modules.  
Serial annunciator output (optional).  
Printer interface for on or off-line printing (optional).  
Contact-by-zone module (optional).  
Surface mount technology.  
The control is housed in a red steel enclosure with back  
lighted panels displaying the status of vital functions. The  
surface mounted enclosure, (trim ring optional) with its  
slim appearance (3-inch depth) is designed to blend with  
any environment. Space is available for two (2) B-7R bat-  
teries.  
The many features of the FC-5C control provide a cost  
effective approach to systems design, and allow a great  
degree of flexibility in one enclosure. Many of these fea-  
tures include Class B, Style B, (with one Class A, Style D)  
initiating circuits and two (2) Class B, Style Y or Class A,  
Style Z notification appliance circuits, expandable from 1.5  
to 2.5 amps each. Fully programmable via integral key-  
pad, the notification appliance circuits may be pro-  
grammed Silenceable, Non-silenceable, Auto-silence  
(program 5 to 30 minutes) and Silence Inhibit (60 sec-  
onds).  
Periodic trouble reminder via software.  
Operating temperature relative humidity.  
Door back box trim ring.  
An ISO 9000-2000 Company  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472 - Tel: 203-484-7161 - Fax: 203-484-7118  
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.  
©2006 Gamewell-FCI. All rights reserved.  
www.gamewell-fci.com  
9020-0458 Rev. G page 1 of 2  
Description (Continued)  
Ordering Information  
Part Number Description  
Also programmable are Alarm Presignal Timer, Alarm  
Verification Timer and Optional Trouble Reminder.  
700-01190  
700-01191  
700-01215  
700-01192  
FC-5C  
(Five zone control communicator)  
FC-5C PCB  
Five Zone Module, replacement board  
FC-5TR  
Trim Ring  
PRT-24  
Supervision of vital components, plug-in modules,  
functional switches and standby batteries is pro-  
vided. In addition, an optional serial annunciator  
driver allows remote alarm annunciation.  
Printer interface module - provides  
RS-232 printer output.  
Specifications  
Includes cable, DB9F and DB25  
adapter.  
Operating temperature:  
Relative humidity:  
Dimensions:  
32° - 120° F (0° - 49° C)  
85 % (non-condensing)  
700-01193  
700-01194  
ADM-24  
Annunciator driver module  
RZA-5  
Remote zone annunciator, 5 zones  
(requires one (1) ADM-24)  
Door  
15 7/32" H x 14 7/32" W  
(38.7 x 36.1 cm)  
15" H x 14 1/2" W x 3" D  
(38.1 cm x 36.8 cm x 7.6 cm)  
18 1/8" H x 17 5/8" W  
(46.0 cm x 44.8 cm)  
Backbox  
Mounts on single gang box.  
RM-5F  
Five-relay module (contact-by-zone)  
CAC-5F  
Trim Ring  
700-01195  
700-01196  
UL Listed Receivers compatible with FC-10C:  
Class “A” initiating circuit converter  
module  
SK-5C  
Software kit (upload/download utility)  
XRM-FC5  
120 VAC, I 00 VA transformer, ex-  
pands NAC total power from 3.0 to  
5.0 amperes.  
Ademoco 685  
Silent Knight 9000  
ITI-CS-4000  
Osborne Hoffman Models 1 / 2  
Radionics 6000/6500  
Sescoa 3000R  
700-01197  
700-01221  
FBI CP220FB  
Sur-guard MLR-2  
600-90000  
MCBL-7  
DACT phone cord, 7 feet long  
(2 required)  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118  
www.gamewell-fci.com 9020-0458 Rev. G page 2 of 2  

相关型号:

700-01198

Ten zone control communicator
GAMEWELL-FCI

700-01199

Ten zone control communicator
GAMEWELL-FCI

700-01201

Ten zone control communicator
GAMEWELL-FCI

700-01202

Ten zone control communicator
GAMEWELL-FCI

700-01203

Ten zone control communicator
GAMEWELL-FCI

700-01204

Ten zone control communicator
GAMEWELL-FCI

700-01205

Ten zone control communicator
GAMEWELL-FCI

700-01206

Ten zone control communicator
GAMEWELL-FCI

700-01207

Ten zone control communicator
GAMEWELL-FCI

700-01213

Ten zone control communicator
GAMEWELL-FCI

700-01215

Five zone control communicator
GAMEWELL-FCI

700-01216

Ten zone control communicator
GAMEWELL-FCI