PF/D0-20(M6) [ETC]
FIBRE OPTIC SENSOR PLASTIC ; 光纤传感器塑料\n型号: | PF/D0-20(M6) |
厂家: | ETC |
描述: | FIBRE OPTIC SENSOR PLASTIC
|
文件: | 总4页 (文件大小:94K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Compact DC Optical Fibre
Photoelectric Switches
PF
Miniature 6 0 x3 1 x1 1 mm optical fibre photoelectric
switches for remote sensing in confined spaces or
detection of small objects
■
■
■
■
■
■
■
■
■
■
■
■
■
Diffuse and separate (through-beam) models
Red light emission models for most applications
Green light to detect red marks on white backgrounds
Coarse and fine sensitivity adjustments
Light received and stability LEDs
Fast response time – 1ms
Switch selection of light on/ dark on (NO/ NC) output
Protection up to IP66
Fine tube types can be bent for positioning
Fibres may be cut to suit applications
Logic output (NPN models)
Self-diagnostic (alarm) output models with off-delay timer
Short-circuit protection
Year
Guarantee
Options and ordering codes
P F
A
–
N
T
G
Compact optical fibre
photoelectric switches
PRICE
—
G
Red light emission
P F
A
INFORMATION
AND ORDERING
Green light
emission
Amplifier
Without timer and
diagnostic output
—
T
NPN output type
PNP output type
N
P
With timer and
diagnostic output
Specifications
Type
Photoelectric switch
Photoelectric switch with timer and self-diagnosis
Models
PFA-N
red
PFA-NG
green
PFA-P
red
PFA-PG
green
PFA-NT
red
PFA-NTG
green
PFA-PT
red
PFA-PTG
green
Emission
Supply voltage
Max. consumption
Response time
Output type
Output state
Load cur rent
Logic output
10-30VDC including peak ripple
≤50mA
≤1ms operation/ reset
≤1ms operation, 30 to 70ms reset
NPN
PNP
NPN
PNP
light on/ dark on (NO/ NC) selectable by switch
100mA
1.5mA
–
1.5mA
–
Self-diagnostic output current
Residual output voltage
Connection cable
–
50mA
1.1V IL=100mA
2 metres long, 3-wire
2 metres long, 4-wire
Electrical protections
LED status indicators
Sensitivity adjustment
Insulation resistance
Dielectric strength
Housing material
against short circuit (autoreset) - polarity reversal - inductive loads
light received - red LED (light), stability - green LED (stab.)
coarse - 1 turn trimmer (sens.), fine - 1 turn trimmer (fine)
> 20 MOhm to 500 VDC
1000VAC 50/ 60Hz for 1 min
ABS
IEC IP66(1)
-25˚C +55˚C (avoid ice on amplifier)(2)
P rotection degree
Operating temperature
Storage temperature
Inter ference by ar tificial light
Inter ference by sunlight
Ambient humidity
Vibration
-40˚ +70˚C
3000 lux
10000 lux
35-85% r.h. operating, 35-95% r.h. storage
10 to 55 Hz, 1.5mm double amplitude (x, y, z direction, respectively 2 hours)
500m/ s2 (approx. 50G) 3 times each in X, Y and Z directions
100g
Shock
Weight (approx.)
(1)
Protection is IP50 when amplifier is used with fibres P2F-DF or P2F-SF. (2) Operating temperature range is -25˚C to +50˚C when amplifiers are mounted close together
e.g. on DIN rail.
PF
Specifications
Type
diffuse
PF/ D0-21
separate (through-beam)
PF/ T0-21
Models
PF/ D0-20 PFU/ D0-20
standard
P2F-DF
fine stainless tube
20mm
PF/ T0-20 PFU/ T0-20
standard
200mm-1.2m(1)
opaque ø1mm-3mm
M4
P2F-SF
Style
fine head
fine head
100mm-400mm(1)
fine stainless tube
60mm
Sensing range
Detectable object
Head thread size
Fibre size
80mm
30mm
transparent and opaque
opaque ø0.5mm
M6
M3
M3
ø1mm active fibre
ø0.5mm active fibre
ø0.5mm active fibre
ø1mm active fibre
ø0.5mm active fibre
ø0.5mm active fibre
-40˚ to +70˚C
Fibre length
Materials
2 metres(2)
fibre: PMMA resin, sheath: polyester
-40˚ to +70˚C -25˚ to +60˚C
Operating
-25˚ to +60˚C
(1) Sensing range 1.2m for PF/ T0-20 with PFL-1 lens (2) Longer fibres possible – contact IMO for availability
Dimensions (mm)
• Fibre unit – separate (through-beam) type - standard head
• Fibre unit – diffuse type – standard head
PF-T0-20 P FU/ T0 -2 0 (high flexible cable)
PF-D0-20 P FU/ D0 -2 0 (high flexible cable)
M4
M3
(P=0.45)
(P=0.7)
11
14
13
2-ø1
ø1
2000
17
2000
• Fibre unit – separate (through-beam) type - fine head
PF/ T0-21
• Fibre unit – diffuse type – fine head
PF/ D0-21
M 2.5
M 3
Ø 1
M 2.5
M 3
2 x Ø1
Length 2 m
Useful ø fibre 0.5mm
Length 2 m
Useful ø fibre 0.5mm
3
11
11
3
2 fibre attachment (supplied)
2 fibre attachment (supplied)
• Fibre unit – separate (through-beam) type – fine stainless-
steel tube headP2F-SF
• Fibre unit – diffuse type – fine stainless-steel tube head
P2F-DF
M3 (P=0.5)
M3 (P=0.5)
0.5~1
12
15
10
8
0.5~1
10
15
2-ø0.5
ø0.5
80
15
80
2000
15
2000
Lens: PFL-1 supplied separately (set of two)
Right-angle beam adapter PFL-2 supplied separately
(set of two)
7
12
12
10
2
Light
emitting hole
M4 (P=0.7)
P2F-S
M4 (P=0.7)
P2F-S
PFL-1
PFL-2
Net weight : 2
Net weight : 2g
Fibre cutter PXC – supplied with all fibres
Note: PFL-1 consists of two lenses, one to be fitted to the
light source fibre and one to the receiver fibre. (Only to be
used with fibre PF/ D0-20.)
8
45
PFL-2 consists of two right-angle beam adaptors, one to be
fitted to either the light source fibre or the receiver fibre or
both. (Only to be used with fibre P2F-S.)
Fibre
Additional fibres available – see following pages – contact IMO for availability
PRICE
INFORMATION
AND ORDERING
PF
Wiring connections
Light
received
indicator
Light
received
indicator
Stable operating level
indicator
Stable operating level
indicator
Brown +
Brown +
1.5 mA
Red
Green
Output
Black
Red
Green
PFA-N
PFA-NG
PFA-P
PFA-PG
Load
Black
Photoelectric
switch-circuit
Photoelectric
switch-circuit
DC
10-30V
DC
10-30V
Load
Output
Blue OV
Blue OV
Light
received
indicator
Light
received
indicator
Stable operating level
indicator
Stable operating level
indicator
Brown +
Brown +
1.5 mA
Red
Green
Red
Green
Output
Black
PFA-NT
PFA-NTG
PFA-PT
PFA-PTG
Load
Output
Black
Photoelectric
switch-circuit
Photoelectric
switch-circuit
Load
Orange *1
Alarm
DC
10-30V
DC
10-30V
Orange *1
Alarm
Blue OV
Blue OV
*1: Self-diagnosis function output
*1: Self-diagnosis function output
Note: the +V, output and OV (gnd) connections are also available on the top of the amplifier in the form of terminals, for operation check (test) purposes.
Timing diagrams
PFA-N, PFA-P, PFA-NG, PFA-PG
PFA-NT, PFA-PT, PFA-NTG, PFA-PTG
Indication lamps
•
“DARK ON” mode
•
“DARK ON” mode
• “LIGHT ON” mode
•
“LIGHT ON” mode
Transistor ON when light is
interrupted.
Transistor ON when light is
interrupted.
Transistor ON when light is
incident.
Transistor ON when light is
incident.
•
Incident light indicator (red “Light” lamp)
Lights upon exposure to incident light in either the
LIGHT-ON or DARK-ON operating mode.
Light is incident
Light is incident
Light is incident
Light is incident
Light is interrupted
Light is interrupted
Light is interrupted
Light is interrupted
•
Stable operating level indicator (green “Stab”
ON
Indicator (Red)
OFF
ON
Indicator (Red)
OFF
ON
Indicator (Red)
OFF
ON
Indicator (Red)
OFF
lamp)
Indicates that the amount of light or shade for detection
by the sensor is at a stable and suitable level for
operation.
Approx. 40 ms
ON
Output transistor
OFF
Approx. 40 ms
ON
Output transistor
OFF
ON
Output transistor
OFF
ON
Output transistor
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Load (Relay)
Load (Relay)
Load (Relay)
Load (Relay)
This lamp lights up when the quantity of light received
has exceeded + 15% of the operating level or it has been
lowered below -15% of the reset level.
Output voltage
H
Output voltage
H
Output voltage
H
Output voltage
H
(Logic circuit)
–NPN only
(Logic circuit)
–NPN only
(Logic circuit)
–NPN only
(Logic circuit)
–NPN only
L
L
L
L
Self-diagnosis function
Relationship between quantity of light received, output and
indication lamps
The self-diagnosis function warns of the decrease in the light value received due to the
deflection of the optical axis or dirty lens surfaces.
P FA-N, P FA-P, P FA-NG, P FA-P G
Output transistor
LIGHT ON
OFF
ON
ON
■ Time char t of the self-diagnosis function
The self-diagnosis output is OFF when the quantity of light received is between the range
66 to 115% of the operating level due to the deflection of the optical axis or buildup of dirt
and this situation as continued over the delay time.
DARK ON
OFF
Light incident indicator
lamp
LIGHT ON
DARK ON
Lights up
Lights up
Goes out
Goes out
Self-diagnosis function timing diagram (LIGHT-ON)
Stable operating level
indication lamp
LIGHT ON
DARK ON
Lights up Goes out Lights up
Lights up Goes out Lights up
Quality of light received
Stable light
receiving area
Stable light
receiving
area
Stable light
interrupting
area
115%
100%
15 15
Quantity of light received
Operating level
%
%
Reset level
77%
66%
P FA-NT, P FA-P T, P FA-NTG, P FA-P TG
Stable light interupting area
Output transistor
light-level increasing
light-level decreasing
LIGHT ON
OFF
OFF
ON
Time
LIGHT ON
ON
ON
OFF
ON
OFF
Detecting
output
light-level increasing
light-level decreasing
DARK ON
DARK ON
OFF
OFF
ON
ON
0.3S*
0.3S*
ON
ON
OFF
OFF
Self-diagnosis
output
Self-diagnosis output
LIGHT ON
DARK ON
ON
ON
ON
ON
OFF
Lights up
Lights up
Goes out
Goes out
Operating
OFF
indication lamp
Lights up
Lights up
Goes out
Goes out
Light incident indication light-level increasing
lamp
L ON OR D ON Lights up
OFF
Stable operating
* Delay time
level indication lamp
light-level decreasing
ON
Goes out
L ON OR D ON
Lights
Lights
Lights
Lights
Goes out
Goes out
Stable operating level
indication lamp
LIGHT ON
DARK ON
If the terminology NO and NC is used, the following
conversion table applies:
Stable
light
inter-
rupting
area
Stable
light
receiving
area
NO: when detecting a target, the
output switches to the ON
state (conduction)
Quantity of light received
Differ-
ential
travel
15
%
15
%
Detection mode
Diffuse
dark on
NC
light on
NO
NC: when detecting a target, the
output switches to the OFF
state (isolation)
115%100%
77% 66%
Retro-reflective
Through beam
NO
NC
Operating
level
Reset
level
LIGHT ON
DARK ON
NO
NC
Reset
level
Operating
level
PF
Setting-up procedure
Optical axis adjustment
■ Diffuse type
■ Separate (through-beam) type
•
•
Visually align the sensor position
The characteristics of detection depend on the
material and shape of the target object.
•
Position the tips of the optical fibres so that they face
each other and encompass the sensing position.
The incident light indication lamp lights (red) when
the optical axes are aligned. Check also that the stable
operating level indicator (green) lights.
•
•
Upon detection of the target object, the incident light
indication lamp lights (red). Check also that the stable
operating level indicator (green) lights.
Sensitivity adjustment
A fine and a coarse sensitivity adjustment permits accurate
adjustment.
■ Procedure of sensitivity adjustment
•
When carrying out a normal detection, set both dials
at the maximum sensitivity value by turning them fully
clockwise.
•
When a photoelectric switch is used for detection of an
object with inadequate contrast, sensitivity adjustment
should be carried out.
Carry out the sensitivity adjustment as follows.
State of detected object
Object
Coarse adjustment dial
Fine adjustment dial
1. Set the fine adjustment dial at the
central position.
Setting position of the
coarse adjustment dial
a
2. Set the coarse adjustment dial at
approximate operating position.
Coarse adjustment dial
Fine adjustment dial
b
Object
3. Obtain the operating position at
the time of presence or absence
of the object to be detected by
means of the fine adjustment dial,
and set at the middle position.
a
Setting position of
the fine adjustment dial
b
Dimensions (mm)
PRICE
INFORMATION
AND ORDERING
➀ Light
Light-receiving indicator
➁ Stab
Stable light level indicator
➂ Fine
Fine sensitivity adjustment
➃ Sens
13.3
7
7.2
8.1
7.4
6
1
2
3
4
5
Cord length
2m/0.2mm2
(66.5)
49.2
11
6.2
11.1
3.5
Coarse sensitivity adjustment
➄ Logic changeover switch
➅ Operation check terminals
Rail type
7.5mm high
15mm high
Dimension A
5
ø3.2
34.5
20
3
ø3.2
3.5
11
2
35 mm-wide IEC standard rail
or Mounting bracket (supplied)
16
17.6
Mounting bracket
supplied
5
3.2
35.4
7.9
10.6
maximum mounting screw torque 1Nm
相关型号: