PF/T0-20(M4) [ETC]

FIBRE OPTIC SENSOR PLASTIC ; 光纤传感器塑料\n
PF/T0-20(M4)
型号: PF/T0-20(M4)
厂家: ETC    ETC
描述:

FIBRE OPTIC SENSOR PLASTIC
光纤传感器塑料\n

光纤 传感器
文件: 总4页 (文件大小:94K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Compact DC Optical Fibre  
Photoelectric Switches  
PF  
Miniature 6 0 x3 1 x1 1 mm optical fibre photoelectric  
switches for remote sensing in confined spaces or  
detection of small objects  
Diffuse and separate (through-beam) models  
Red light emission models for most applications  
Green light to detect red marks on white backgrounds  
Coarse and fine sensitivity adjustments  
Light received and stability LEDs  
Fast response time – 1ms  
Switch selection of light on/ dark on (NO/ NC) output  
Protection up to IP66  
Fine tube types can be bent for positioning  
Fibres may be cut to suit applications  
Logic output (NPN models)  
Self-diagnostic (alarm) output models with off-delay timer  
Short-circuit protection  
Year  
Guarantee  
3
Options and ordering codes  
P F  
A
N
T
G
Compact optical fibre  
photoelectric switches  
PRICE  
G
Red light emission  
P F  
A
INFORMATION  
AND ORDERING  
Green light  
emission  
Amplifier  
Without timer and  
diagnostic output  
T
NPN output type  
PNP output type  
N
P
With timer and  
diagnostic output  
Specifications  
Type  
Photoelectric switch  
Photoelectric switch with timer and self-diagnosis  
Models  
PFA-N  
red  
PFA-NG  
green  
PFA-P  
red  
PFA-PG  
green  
PFA-NT  
red  
PFA-NTG  
green  
PFA-PT  
red  
PFA-PTG  
green  
Emission  
Supply voltage  
Max. consumption  
Response time  
Output type  
Output state  
Load cur rent  
Logic output  
10-30VDC including peak ripple  
50mA  
1ms operation/ reset  
1ms operation, 30 to 70ms reset  
NPN  
PNP  
NPN  
PNP  
light on/ dark on (NO/ NC) selectable by switch  
100mA  
1.5mA  
1.5mA  
Self-diagnostic output current  
Residual output voltage  
Connection cable  
50mA  
1.1V IL=100mA  
2 metres long, 3-wire  
2 metres long, 4-wire  
Electrical protections  
LED status indicators  
Sensitivity adjustment  
Insulation resistance  
Dielectric strength  
Housing material  
against short circuit (autoreset) - polarity reversal - inductive loads  
light received - red LED (light), stability - green LED (stab.)  
coarse - 1 turn trimmer (sens.), fine - 1 turn trimmer (fine)  
> 20 MOhm to 500 VDC  
1000VAC 50/ 60Hz for 1 min  
ABS  
IEC IP66(1)  
-25˚C +55˚C (avoid ice on amplifier)(2)  
P rotection degree  
Operating temperature  
Storage temperature  
Inter ference by ar tificial light  
Inter ference by sunlight  
Ambient humidity  
Vibration  
-40˚ +70˚C  
3000 lux  
10000 lux  
35-85% r.h. operating, 35-95% r.h. storage  
10 to 55 Hz, 1.5mm double amplitude (x, y, z direction, respectively 2 hours)  
500m/ s2 (approx. 50G) 3 times each in X, Y and Z directions  
100g  
Shock  
Weight (approx.)  
(1)  
Protection is IP50 when amplifier is used with fibres P2F-DF or P2F-SF. (2) Operating temperature range is -25˚C to +50˚C when amplifiers are mounted close together  
e.g. on DIN rail.  
PF  
Specifications  
Type  
diffuse  
PF/ D0-21  
separate (through-beam)  
PF/ T0-21  
Models  
PF/ D0-20 PFU/ D0-20  
standard  
P2F-DF  
fine stainless tube  
20mm  
PF/ T0-20 PFU/ T0-20  
standard  
200mm-1.2m(1)  
opaque ø1mm-3mm  
M4  
P2F-SF  
Style  
fine head  
fine head  
100mm-400mm(1)  
fine stainless tube  
60mm  
Sensing range  
Detectable object  
Head thread size  
Fibre size  
80mm  
30mm  
transparent and opaque  
opaque ø0.5mm  
M6  
M3  
M3  
ø1mm active fibre  
ø0.5mm active fibre  
ø0.5mm active fibre  
ø1mm active fibre  
ø0.5mm active fibre  
ø0.5mm active fibre  
-40˚ to +70˚C  
Fibre length  
Materials  
2 metres(2)  
fibre: PMMA resin, sheath: polyester  
-40˚ to +70˚C -25˚ to +60˚C  
Operating  
-25˚ to +60˚C  
(1) Sensing range 1.2m for PF/ T0-20 with PFL-1 lens (2) Longer fibres possible – contact IMO for availability  
Dimensions (mm)  
• Fibre unit – separate (through-beam) type - standard head  
• Fibre unit – diffuse type – standard head  
PF-T0-20 P FU/ T0 -2 0 (high flexible cable)  
PF-D0-20 P FU/ D0 -2 0 (high flexible cable)  
M4  
M3  
(P=0.45)  
(P=0.7)  
11  
14  
13  
2-ø1  
ø1  
2000  
17  
2000  
• Fibre unit – separate (through-beam) type - fine head  
PF/ T0-21  
• Fibre unit – diffuse type – fine head  
PF/ D0-21  
M 2.5  
M 3  
Ø 1  
M 2.5  
M 3  
2 x Ø1  
Length 2 m  
Useful ø fibre 0.5mm  
Length 2 m  
Useful ø fibre 0.5mm  
3
11  
11  
3
2 fibre attachment (supplied)  
2 fibre attachment (supplied)  
• Fibre unit – separate (through-beam) type – fine stainless-  
steel tube headP2F-SF  
• Fibre unit – diffuse type – fine stainless-steel tube head  
P2F-DF  
M3 (P=0.5)  
M3 (P=0.5)  
0.5~1  
12  
15  
10  
8
0.5~1  
10  
15  
2-ø0.5  
ø0.5  
80  
15  
80  
2000  
15  
2000  
Lens: PFL-1 supplied separately (set of two)  
Right-angle beam adapter PFL-2 supplied separately  
(set of two)  
7
12  
12  
10  
2
Light  
emitting hole  
M4 (P=0.7)  
P2F-S  
M4 (P=0.7)  
P2F-S  
PFL-1  
PFL-2  
Net weight : 2  
Net weight : 2g  
Fibre cutter PXC – supplied with all fibres  
Note: PFL-1 consists of two lenses, one to be fitted to the  
light source fibre and one to the receiver fibre. (Only to be  
used with fibre PF/ D0-20.)  
8
45  
PFL-2 consists of two right-angle beam adaptors, one to be  
fitted to either the light source fibre or the receiver fibre or  
both. (Only to be used with fibre P2F-S.)  
Fibre  
Additional fibres available – see following pages – contact IMO for availability  
PRICE  
INFORMATION  
AND ORDERING  
PF  
Wiring connections  
Light  
received  
indicator  
Light  
received  
indicator  
Stable operating level  
indicator  
Stable operating level  
indicator  
Brown +  
Brown +  
1.5 mA  
Red  
Green  
Output  
Black  
Red  
Green  
PFA-N  
PFA-NG  
PFA-P  
PFA-PG  
Load  
Black  
Photoelectric  
switch-circuit  
Photoelectric  
switch-circuit  
DC  
10-30V  
DC  
10-30V  
Load  
Output  
Blue OV  
Blue OV  
Light  
received  
indicator  
Light  
received  
indicator  
Stable operating level  
indicator  
Stable operating level  
indicator  
Brown +  
Brown +  
1.5 mA  
Red  
Green  
Red  
Green  
Output  
Black  
PFA-NT  
PFA-NTG  
PFA-PT  
PFA-PTG  
Load  
Output  
Black  
Photoelectric  
switch-circuit  
Photoelectric  
switch-circuit  
Load  
Orange *1  
Alarm  
DC  
10-30V  
DC  
10-30V  
Orange *1  
Alarm  
Blue OV  
Blue OV  
*1: Self-diagnosis function output  
*1: Self-diagnosis function output  
Note: the +V, output and OV (gnd) connections are also available on the top of the amplifier in the form of terminals, for operation check (test) purposes.  
Timing diagrams  
PFA-N, PFA-P, PFA-NG, PFA-PG  
PFA-NT, PFA-PT, PFA-NTG, PFA-PTG  
Indication lamps  
“DARK ON” mode  
“DARK ON” mode  
• “LIGHT ON” mode  
“LIGHT ON” mode  
Transistor ON when light is  
interrupted.  
Transistor ON when light is  
interrupted.  
Transistor ON when light is  
incident.  
Transistor ON when light is  
incident.  
Incident light indicator (red “Light” lamp)  
Lights upon exposure to incident light in either the  
LIGHT-ON or DARK-ON operating mode.  
Light is incident  
Light is incident  
Light is incident  
Light is incident  
Light is interrupted  
Light is interrupted  
Light is interrupted  
Light is interrupted  
Stable operating level indicator (green “Stab”  
ON  
Indicator (Red)  
OFF  
ON  
Indicator (Red)  
OFF  
ON  
Indicator (Red)  
OFF  
ON  
Indicator (Red)  
OFF  
lamp)  
Indicates that the amount of light or shade for detection  
by the sensor is at a stable and suitable level for  
operation.  
Approx. 40 ms  
ON  
Output transistor  
OFF  
Approx. 40 ms  
ON  
Output transistor  
OFF  
ON  
Output transistor  
OFF  
ON  
Output transistor  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
Load (Relay)  
Load (Relay)  
Load (Relay)  
Load (Relay)  
This lamp lights up when the quantity of light received  
has exceeded + 15% of the operating level or it has been  
lowered below -15% of the reset level.  
Output voltage  
H
Output voltage  
H
Output voltage  
H
Output voltage  
H
(Logic circuit)  
–NPN only  
(Logic circuit)  
–NPN only  
(Logic circuit)  
–NPN only  
(Logic circuit)  
–NPN only  
L
L
L
L
Self-diagnosis function  
Relationship between quantity of light received, output and  
indication lamps  
The self-diagnosis function warns of the decrease in the light value received due to the  
deflection of the optical axis or dirty lens surfaces.  
P FA-N, P FA-P, P FA-NG, P FA-P G  
Output transistor  
LIGHT ON  
OFF  
ON  
ON  
Time char t of the self-diagnosis function  
The self-diagnosis output is OFF when the quantity of light received is between the range  
66 to 115% of the operating level due to the deflection of the optical axis or buildup of dirt  
and this situation as continued over the delay time.  
DARK ON  
OFF  
Light incident indicator  
lamp  
LIGHT ON  
DARK ON  
Lights up  
Lights up  
Goes out  
Goes out  
Self-diagnosis function timing diagram (LIGHT-ON)  
Stable operating level  
indication lamp  
LIGHT ON  
DARK ON  
Lights up Goes out Lights up  
Lights up Goes out Lights up  
Quality of light received  
Stable light  
receiving area  
Stable light  
receiving  
area  
Stable light  
interrupting  
area  
115%  
100%  
15 15  
Quantity of light received  
Operating level  
%
%
Reset level  
77%  
66%  
P FA-NT, P FA-P T, P FA-NTG, P FA-P TG  
Stable light interupting area  
Output transistor  
light-level increasing  
light-level decreasing  
LIGHT ON  
OFF  
OFF  
ON  
Time  
LIGHT ON  
ON  
ON  
OFF  
ON  
OFF  
Detecting  
output  
light-level increasing  
light-level decreasing  
DARK ON  
DARK ON  
OFF  
OFF  
ON  
ON  
0.3S*  
0.3S*  
ON  
ON  
OFF  
OFF  
Self-diagnosis  
output  
Self-diagnosis output  
LIGHT ON  
DARK ON  
ON  
ON  
ON  
ON  
OFF  
Lights up  
Lights up  
Goes out  
Goes out  
Operating  
OFF  
indication lamp  
Lights up  
Lights up  
Goes out  
Goes out  
Light incident indication light-level increasing  
lamp  
L ON OR D ON Lights up  
OFF  
Stable operating  
* Delay time  
level indication lamp  
light-level decreasing  
ON  
Goes out  
L ON OR D ON  
Lights  
Lights  
Lights  
Lights  
Goes out  
Goes out  
Stable operating level  
indication lamp  
LIGHT ON  
DARK ON  
If the terminology NO and NC is used, the following  
conversion table applies:  
Stable  
light  
inter-  
rupting  
area  
Stable  
light  
receiving  
area  
NO: when detecting a target, the  
output switches to the ON  
state (conduction)  
Quantity of light received  
Differ-  
ential  
travel  
15  
%
15  
%
Detection mode  
Diffuse  
dark on  
NC  
light on  
NO  
NC: when detecting a target, the  
output switches to the OFF  
state (isolation)  
115%100%  
77% 66%  
Retro-reflective  
Through beam  
NO  
NC  
Operating  
level  
Reset  
level  
LIGHT ON  
DARK ON  
NO  
NC  
Reset  
level  
Operating  
level  
PF  
Setting-up procedure  
Optical axis adjustment  
Diffuse type  
Separate (through-beam) type  
Visually align the sensor position  
The characteristics of detection depend on the  
material and shape of the target object.  
Position the tips of the optical fibres so that they face  
each other and encompass the sensing position.  
The incident light indication lamp lights (red) when  
the optical axes are aligned. Check also that the stable  
operating level indicator (green) lights.  
Upon detection of the target object, the incident light  
indication lamp lights (red). Check also that the stable  
operating level indicator (green) lights.  
Sensitivity adjustment  
A fine and a coarse sensitivity adjustment permits accurate  
adjustment.  
Procedure of sensitivity adjustment  
When carrying out a normal detection, set both dials  
at the maximum sensitivity value by turning them fully  
clockwise.  
When a photoelectric switch is used for detection of an  
object with inadequate contrast, sensitivity adjustment  
should be carried out.  
Carry out the sensitivity adjustment as follows.  
State of detected object  
Object  
Coarse adjustment dial  
Fine adjustment dial  
1. Set the fine adjustment dial at the  
central position.  
Setting position of the  
coarse adjustment dial  
a
2. Set the coarse adjustment dial at  
approximate operating position.  
Coarse adjustment dial  
Fine adjustment dial  
b
Object  
3. Obtain the operating position at  
the time of presence or absence  
of the object to be detected by  
means of the fine adjustment dial,  
and set at the middle position.  
a
Setting position of  
the fine adjustment dial  
b
Dimensions (mm)  
PRICE  
INFORMATION  
AND ORDERING  
Light  
Light-receiving indicator  
Stab  
Stable light level indicator  
Fine  
Fine sensitivity adjustment  
Sens  
13.3  
7
7.2  
8.1  
7.4  
6
1
2
3
4
5
Cord length  
2m/0.2mm2  
(66.5)  
49.2  
11  
6.2  
11.1  
3.5  
Coarse sensitivity adjustment  
Logic changeover switch  
Operation check terminals  
Rail type  
7.5mm high  
15mm high  
Dimension A  
5
ø3.2  
34.5  
20  
3
ø3.2  
3.5  
11  
2
35 mm-wide IEC standard rail  
or Mounting bracket (supplied)  
16  
17.6  
Mounting bracket  
supplied  
5
3.2  
35.4  
7.9  
10.6  
maximum mounting screw torque 1Nm  

相关型号:

PF0

Axial Leaded Hermetically Sealed Fast Rectifier Diode
SEMTECH

PF0001

EN60 320-1 Standard Sheet C14 Class I Cold Condition (Fused)
BULGIN

PF0001/28

EN60 320-1 Standard Sheet C14 Class I Cold Condition (Fused)
BULGIN

PF0001/63

EINBAUSTECKER 6.3MM SCHRAUBBEFESTIGUNG
ETC

PF0001/PC

EN60 320-1 Standard Sheet C14 Class I Cold Condition (Fused)
BULGIN

PF0002

Analog IC
ETC

PF0002/28

EN60 320-1 Standard Sheet C14 Class I Cold Condition (Fused)
BULGIN

PF0006

EN60 320-1 Standard Sheet C18 Class II Cold Condition (Fused)
BULGIN

PF0006/28

EN60 320-1 Standard Sheet C18 Class II Cold Condition (Fused)
BULGIN

PF0007/28

EN60 320-1 Standard Sheet C18 Class II Cold Condition (Fused)
BULGIN

PF0008

Analog IC
ETC

PF0008PR22DP

Connector Accessory, Contact
AMPHENOL