G3MC-102P [ETC]
;型号: | G3MC-102P |
厂家: | ETC |
描述: | 光电 输出元件 |
文件: | 总5页 (文件大小:139K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
9
Solid State Relay
G3MC
Compact, Low-cost Fail-safe SSR that
Switches up to 2 Amps
1 Unlike conventional solid-state devices,
Omron’s new fail-safe technology
eleminates the need for external fuse or
safety circuitry in many applications
1 Smaller footprint (approximately 20%
smaller than G3MB) is ideal for close
PCB mounting applications
èòå
1 Built in snubber circuit
1 VDE versions available
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G3MC-101P-DC12).
Isolation
Zero-cross function
Yes
Built-in snubber
circuit
Rated output load
Rated input voltage
Part number
G3MC-101P
Phototriac
Yes
1 A at 100 to 120 VAC
(75 to 132 VAC)
5 VDC
12 VDC
24 VDC
5 VDC
No
G3MC-101PL
G3MC-102P
G3MC-102PL
G3MC-201P
G3MC-201PL
G3MC-202P
G3MC-202PL
12 VDC
24 VDC
5 VDC
Yes
No
2 A at 100 to 120 VAC
(75 to 132 VAC)
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
Yes
No
1 A at 100 to 240 VAC
(75 to 264 VAC)
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
5 VDC
Yes
No
2 A at 100 to 240 VAC
(75 to 264 VAC)
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
Note: VDE versions available. Contact your local Omron representitive
G3MC
G3MC
Specifications
3 RATINGS (AMBIENT TEMPERATURE 25°C)
Input
Rated voltage
Operating voltage
Impedance
Voltage levels
Must operate voltage
4 VDC max.
Must dropout voltage
5 VDC
4 to 6 VDC
300Ω ±20%
800Ω ±20%
1.6kΩ ±20%
1 VDC min.
12 VDC
24 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
9.6 VDC max.
19.2 VDC max.
Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Part number
Applicable load
Rated load voltage
100 to 120 VAC
100 to 240 VAC
100 to 120 VAC
100 to 240 VAC
Load voltage range
75 to 132 VAC
75 to 264 VAC
75 to 132 VAC
75 to 264 VAC
Load current
0.1 to 1 A
Surge current
G3MC-101P(L)
G3MC-201P(L)
G3MC-102P(L)
G3MC-202P(L)
8 A (60 Hz, 1 cycle)
0.1 to 2 A
30 A (60 Hz, 1 cycle)
3 CHARACTERISTICS
Item
G3MC-101P /
G3MC-102P
G3MC-101PL /
G3MC-102PL
G3MC-201P /
G3MC-202P
G3MC-201PL /
G3MC-202PL
Operate time
1/2 of load power source 1 ms max.
cycle + 1 ms
1/2 of load power source 1 ms max.
cycle + 1 ms
Release time
1/2 of load power source cycle + 1 ms)
1.6 V (RMS) max.
Output ON voltage drop
Leakage current
1 mA max. (at 100 VAC)
1.5 mA max. (at 200 VAC)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
1,000 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min
Malfunction: 10 to 55 Hz, 0.75-mm double amplitude
2
Malfunction: 1,000 m/s (approx. 100G)
Operating: --30°C to 80°C (with no icing or condensation)
Storage: --30°C to 100°C (with no icing or condensation)
Approved standards
Ambient humidity
Weight
UL508 File No. E64562, CSA C22.2 (No. 14, No. 950) File No. LR35535, EN60950 File No. 5925UG
Operating: 45% to 85%
Approx. 2.5 g
7
G3MC
G3MC
Engineering Data
3 G3MC-101P(L), G3MC-201P(L)
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to
half the rated value if it occurs repeatedly.)
Energizing time (ms)
Ambient temperature (°C)
3 G3MC-102P(L), G3MC-202P(L)
Load Current vs. Ambient
Inrush Current Resistivity
Temperature Characteristics
Non-repetitive (Keep the inrush current to
half the rated value if it occurs repeatedly.)
30
2.5
2.0
1.5
1.0
0.5
0
20
10
0
10
30 50 100 200 500 1000
5000
--30 --20
0
20 25 40
60
80
100
Energizing time (ms)
Ambient temperature (°C)
8
G3MC
G3MC
Dimensions
Unit: mm (inch)
G3MC-101P
G3MC-101PL
G3MC-201P
G3MC-201PL
PCB Dimensions
(Bottom View)
Four, 1.0-dia. holes
4.5 max.
24.5 max.
13.5 max.
Terminal Arrangement
(Bottom View)
G3MC-102P
G3MC-102PL
G3MC-202P
G3MC-202PL
PCB Dimensions
(Bottom View)
4.50 max.
(0.18)
2.54
(0.10)
24.5 max.
(0.97)
Four, 1.0
(0.04) dia. holes
2.54
(0.10)
0.8.
(0.03)
20.5 max.
(0.81)
Terminal Arrangement
(Bottom View)
4-- 3+
2
1
(--)4 3(+)
2
1
INPUT
LOAD
0.25
(0.01)
3.5
(0.14)
Four, 0.7
(0.03)
2.54
(0.10)
Four, 1.6
(0.06)
1.2
(0.05)
10.16
(0.40)
7.62
(0.30)
2.54
(0.10)
9
G3MC
G3MC
Precautions
closely, make sure that the Units are properly ventilated by taking am-
bient temperature rises into consideration. If Units are closely
mounted and used in places with no ventilation, the load current of
each Unit must be 1/2 of the rated load current.
3 GENERAL PRECAUTIONS
Do not touch the terminals of the SSR while power is being
supplied to the SSR. The terminals are charged with the power, and
an electric shock may be received by touching the terminals.
The built-in capacitor may have a residual voltage after the SSR is
turned off. Be sure to discharge the residual voltage before
touching the terminals of the SSR, otherwise an electric shock may
be received.
3 MOUNTING
1.
2.
3.
Make sure that no excessive voltage or current is imposed on
or flows to the input or output circuit of the SSR, otherwise
the SSR may malfunction or burn.
Solder the terminals of the SSR properly under the required
soldering conditions. The SSR may be abnormally heated and
burn if power is supplied to the terminals soldered incorrectly.
Do not short-circuit the load of the SSR while power is supplied
to the SSR. Do not short-circuit the power supply through the
SSR. The SSR may be damaged, malfunction, or burn if the
load or power supply is short-circuited.
3 CORRECT USE
The terminals of the SSR are highly heat-conductive. Each terminal
must be soldered within 10 s at 260°C or within 5 s at 350°C.
The SSR is of a thin-profile construction. To maintain the vibration re-
sistance of the SSR, make sure that the space between the SSR and
PCB is 0.1 mm maximum. Lifting of the PCB can be prevented by set-
ting the hole diameter of the PCBs on both sides slightly smaller than
the actual terminal dimension.
Select the model without the zero-cross function when using the Unit
for phase control output.
The casing works as a heat sink. When mounting two or more Units
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
9
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
885 Milner Avenue
Schaumburg, IL 60173
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
01/00
Specifications subject to change without notice.
Printed in U.S.A.
相关型号: