G3MC-201P-VD-1 [OMRON]
Trigger Output SSR;型号: | G3MC-201P-VD-1 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Trigger Output SSR 输出元件 光电 |
文件: | 总4页 (文件大小:455K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
G3MC
Solid State Relays
Reinforced Insulation Models
Added to Compact,
Thin-profile Series of SSRs
for PCBs
• 4.5-mm thin design for high-density PCB applications.
• DC input and AC output for applicable load of 1A (at 40°C)
and 2A (at 25°C).
• Compact, thin-profile SSR of monoblock construction with
an all-in-one lead frame incorporates a PCB, terminals and
heat sink
RoHS Compliant
Refer to "Solid State Relays Common Precautions".
■Model Number Legend
1. Rated Load Power Supply Voltage
4. Zero Cross Function
G3MC-@@@@@-@@
—
—
— — —
1: Maximum operating voltage higher than
100 V, lower than 200 V
Blank: Equipped with zero cross function
1
2
3 4
5
G
3
M
C
L
: Not equipped with zero cross
function
2: Maximum operating voltage higher than
200 V, lower than 300 V
5. Certification
2. Rated Load Current
01: 1 A
Blank: Certified by UL and CSA (standard
models)
02: 2 A
-VD : Certified by UL, CSA and EN
-VD-1:Certified by UL, CSA and EN
(reinforced insulation models)
3. Terminal Type
P: PCB terminals
■List of Models
Zero cross
function
Snubber
circuit
Minimun
packing unit
Isolation
Indicator
Rated output load
Rated input voltage
Model
5 VDC
12 VDC
24 VDC
5 VDC
G3MC-101P
G3MC-101P-VD
Yes
No
1 A at 100 to 120 VAC
G3MC-101PL
G3MC-101PL-VD
12 VDC
24 VDC
5 VDC
G3MC-201P
Yes
No
12 VDC
24 VDC
5 VDC
G3MC-201P-VD
G3MC-201P-VD-1
100 pcs
G3MC-201PL
G3MC-201PL-VD
G3MC-201PL-VD-1
Phototriac
No
Yes
1 A at 100 to 240 VAC
12 VDC
24 VDC
5 VDC
G3MC-202P
Yes
No
12 VDC
24 VDC
5 VDC
G3MC-202P-VD
G3MC-202P-VD-1
2 A at 100 to 240 VAC
G3MC-202PL
G3MC-202PL-VD
G3MC-202PL-VD-1
12 VDC
24 VDC
Note. Refer to the "List of Certified Models" for UL, CSA, and EN approved models.
1
G3MC
Solid State Relays
■Ratings (at an Ambient Temperature of 25•C)
●Input (Each model has 5-VDC, 12-VDC, and 24-VDC input versions.)
Rated voltage Operating voltage
Impedance Must operate voltage level Must release voltage level
5 VDC
12 VDC
24 VDC
4 to 6 VDC
300Ω 20%
800Ω 20%
1.6 kΩ 20%
4 VDC max.
9.6 to 14.4 VDC
19.2 to 28.8 VDC
9.6 VDC max.
19.2 VDC max.
1 VDC min.
●Output
Item
Applicable load
Rated load voltage Load voltage range Load current
Inrush current
Model
G3MC-101P (-VD)
G3MC-101PL (-VD)
100 to 120 VAC
50/60 Hz
75 to 132 VAC
50/60 Hz
8 A
0.1 to 1 A *
(60 Hz, 1 cycle)
G3MC-201P (-VD) (-1)
G3MC-201PL (-VD) (-1)
100 to 240 VAC
50/60 Hz
75 to 264 VAC
50/60 Hz
G3MC-202P (-VD) (-1)
G3MC-202PL (-VD) (-1)
100 to 240 VAC
50/60 Hz
75 to 264 VAC
50/60 Hz
30 A
(60 Hz, 1 cycle)
0.1 to 2 A *
*
The load current varies depending on the ambient temperature. Refer to Load Current
vs. Ambient Temperature under Engineering Data.
■Characteristics
Model
Item
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
G3MC-101P(-VD)
G3MC-101PL(-VD)
1 ms max.
1/2 of load power source cycle +
1 ms max.
1/2 of load power source cycle +
1 ms max.
Operate time
1 ms max.
Release time
1/2 of load power source cycle + 1 ms max.
1.6 V (RMS) max.
Output ON voltage drop
Leakage current
1 mA max. (at 100 VAC)
1.5 mA max. (at 200 VAC)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Storage temperature
1,000 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min between input and output (3,000 VAC, 50/60 Hz for 1 min for G3MC-@@@-VD-1)
10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
1,000 m/s2
G
3
M
C
-30•C to 100•C (with no icing or condensation)
Ambient operating
temperature
-30•C to 80•C (with no icing or condensation)
Ambient operating
humidity
45% to 85%RH
Weight
Approx. 2.5 g (Approx. 3.8 g for G3MC-202P(L)(-VD)(-1)
■Engineering Data
●Load Current vs. Ambient Temperature
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
1.2
G3MC-202PL(-VD)(-1)
2.5
1.0
2.0
1.5
1.0
0.5
0
0.8
0.6
0.4
0.2
0
?30
?
20
0
20
40
60
80
100
?40
?20
0
20 25 40
60
80 100
Ambient temperature (°C)
Ambient temperature (°C)
2
G3MC
Solid State Relays
●One Cycle Surge Current: Non-repetitive Keep the inrush current to half the read value if it occurs repeatedly.
G3MC-101P(-VD)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-202P(-VD)(-1)
G3MC-201PL(-VD)(-1)
G3MC-202PL(-VD)(-1)
10
40
8
6
4
2
0
30
20
10
0
10
30 50 100
300 500 1,000
5,000
10
30 50 100
300 500 1,000
5,000 10,000
Energized time (ms)
Energized time (ms)
■Dimensions
(Unit: mm)
G3MC-101P(-VD)
PCB Dimensions
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
G3MC-101PL(-VD)
G3MC-201P(-VD)(-1)
G3MC-201PL(-VD)(-1)
4.5 max.
24.5 max.
2.54
Four, 1.0-dia. holes
(−)4 3(+)
INPUT
2
1
13.5 max.
0.8
G
3
M
C
2.54
LOAD
3.5
2.54
0.25
4-1.6
4-0.7
1.2
10.16
7.62
2.54
G3MC-202P(-VD)(-1)
G3MC-202PL(-VD)(-1)
PCB Dimensions
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
4.5 max.
24.5 max.
2.54
Four, 1.0-dia. holes
(−)4 3(+)
INPUT
2
1
2.54
LOAD
20.5 max.
0.8
3.5
2.54
10.16
0.25
4-1.6
4-0.7
1.2
7.62
2.54
■Safety Precautions
●Please refer to “Solid State Relays Common Precautions” for correct use.
Precautions for Correct Use
• The terminals are made of highly heat-conductive materials. Each
terminal must be soldered within 10 s at 260°C or within 5 s at
350°C.
• The SSR is of a thin-profile construction. To maintain the vibration
resistance of the SSR, make sure that the space between the SSR
and PCB is 0.1 mm maximum. Lifting of the PCB can be prevented
by setting the hole diameter of the PCBs on both sides slightly
smaller than the actual terminal dimension.
• Although LOAD is incorporated with snubber circuit, do not wiring
high voltage line and power line together with or in the same duct
as the SSR. Doing so may result in malfunction or damage due to
induction.
• The input circuit is not incorporated with reverse connection
protection circuit. Make sure to check the polarity when wiring.
• Connect the surge absorbers (varistors) in parallel at both ends of
the LOAD terminal when applying a surge voltage over 250 V peak
for G3MC-10@P(L)(-VD), and over 450V peak for
G3MC-20@P(L)(-VD)(-1).
• Select the model without the zero-cross function when using the
Unit for phase control output.
• The casing works as a heat sink. When mounting two or more
Units closely, make sure that the Units are properly ventilated by
taking ambient temperature rises into consideration. If Units are
closely mounted and used in places with no ventilation, the load
current of each Unit must be 1/2 of the rated load current.
Load
INPUT
LOAD
SSR
3
G3MC
Solid State Relays
G
3
M
C
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. J108-E1-04
0812(0207)(O)
4