ER12-30J3PB [ETC]
SWITCH COMPONENT HANDLE BLACK;型号: | ER12-30J3PB |
厂家: | ETC |
描述: | SWITCH COMPONENT HANDLE BLACK |
文件: | 总90页 (文件大小:22439K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Disconnect switches — 11
Section
page
Description
The power of space
Compact Circuit Protector disconnect switches
Compact Circuit Protector Base (CCP2B - CUBEFuse)
Class CC, UL supplemental and IEC 10x38 (CCP2)
Accessories for Class CC, UL supp. and IEC 10x38 CCP2
Multi-wire lug kits
36-37
38-42
43-47
43
The BussmannTM series Compact Circuit
Protector for Class CF CUBEFuseTM
delivers the smallest footprint compared
to any Class J disconnect solution —
requiring up to 51% less space.
Selector and pistol handles, shafts, NFPA 79 compliant
handles
44
Auxiliary contacts
PLC fuse monitors
45
46-47
How to order Class CC, UL supplemental and IEC
10x38 switches
48-51
52-53
Low profile Class CC and G, UL supplemental and
IEC 10x38 (CCPLP)
UL 98 fused disconnect switches, 30 to 800 A
Introduction and agency information
Product line summary — UL
54
55
30 A Class CC and compact Class J
30 A standard Class J
56-57
58-59
60-61
62-63
64-65
66-68
69-70
60 A compact Class J
60 A standard Class J
100 A standard Class J
200 A and 400 A standard Class J
600 A standard Class J and 800 A Class L
UL 98 non-fused disconnect switches, 30 to 1200 A
Introduction, agency information and IEC product summary
UL product summary
71
72
30 A, 60 A and 100 A compact
73-74
75-76
77-78
100 A, 200 A and 400 A standard
600 A, 800 A, 1000 A and 1200 A standard
UL 508 non-fused disconnect switches, 16 to 80 A
Introduction, agency information and IEC product summary
UL product summary
Contents
79
80
Section
page
Description
16 A, 25 A, 40 A, 63 A and 80 A
81-83
Compact Circuit Protector disconnect switches
Class CF CUBEFuse up to 100 A (CCP2-CF)
Class CF CUBEFuse 200 and 400 A (CCP2-CF)
Accessories for CUBEFuse CCP2
Multi-wire lug kits
Enclosed UL 98 and UL 508 disconnect switches
Introduction and agency information
Fused UL 98 enclosed disconnects, 30 to 800 A
Non-fused UL 98 enclosed disconnects, 30 to 1200 A
Non-fused UL 508 enclosed disconnects, 16 to 80 A
2-8
9-12
13-
84
85-86
87-88
89-90
13-14
Selector and pistol handles, shafts, NFPA 79 compliant
handles
15-16
Flange handle rod and cable operators
200 and 400 A switch rotary mechanisms
Auxiliary contacts
17
18
19-20
21-22
23-35
23-30
32-35
PLC fuse monitors (up to 100 A switches)
How to order Class CF switches
Switches up to 100 A
200 and 400 A switches
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-1
Eaton.com/bussmannseries
11 — Disconnect switches
Compact Circuit Protector
UL 98 Class CF disconnect switches from 30 to 400 A
Class CF CCP contents
Section page
30, 60 and 100 amp switches
Descriptions and specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Catalog numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Terminal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8
200 and 400 A switches
Descriptions and specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-10
Catalog numbers and horsepower ratings . . . . . . . . . . . . . . . . . . . . . 10
Available lugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
Accessories
CCP2 switch up to 100 A
with and without rotary operation mechanisms
Multi-wire lug kits
30, 60 and 100 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
200 and 400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Handles and shafts
Selector and pistol handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Handle shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
NFPA 79 compliant handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Flange handle rod and cable operators . . . . . . . . . . . . . . . . . . . . . . . . 17
200 and 400 A switches
Front rotary mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Side rotary mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Terminal shroud kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Phase barrier kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Handle extension. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Auxiliary contacts
30, 60 and 100 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
200 and 400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
PLC fuse monitor (30, 60 and 100 A switches). . . . . . . . . . . . . . . .21-22
How to order
200 A CCP2 switch
with and without rotary operation mechanisms
30 and 60 A switches
Switch only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Front and right side rotary switches . . . . . . . . . . . . . . . . . . . . . .24-25
Left side rotary switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
100 A switches
Switch only. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Front and right side rotary switches . . . . . . . . . . . . . . . . . . . . . .28-29
Left side rotary switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
200 and 400 A switches
200 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32-33
400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34-35
400 A CCP2 switch
with and without rotary operation mechanisms
11-2
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Catalog symbols for 30, 60 and 100 A switches
Conductors/terminals
•ꢀ
75°C Cu, see conductor tables for size, type and torque
information
Symbol
CCP2-(pole)-(amps)CF
Description
Switch only
•ꢀ
•ꢀ
Box lug, single/dual conductor
CCP2R-(pole)-(amps)CF Right front rotary, clockwise operated switch
Fork terminal suitable for line, load or accessory connection, max.
30 A suitable for use with:
CCP2RL-(pole)-(amps)CF Left front rotary, clockwise operated switch
•ꢀ 10-24 screw for 30 and 60 A switches
•ꢀ 1/4-28 screw for 100 A switches
CCP2S-(pole)-(amps)CF
CCP2SL-(pole)-(amps)CF
Right side rotary, clockwise operated switch
Left side rotary, counterclockwise operated
switch
•ꢀ
Multi-wire lug kits — see accessories for details
Description
Storage and operating temperature
The revolutionary, next generation Bussmann™ series Compact
Circuit Protector (cat. no. CCP2) is a fused UL® 98 branch circuit
disconnect switch utilizing the UL Class CF time-delay or fast-acting
CUBEFuse™ with Class J electrical performance. With up to a 51
percent smaller footprint than a traditional fusible solution, these
switches provide a high 200 kA SCCR to help improve panel and
assembly SCCR.
•ꢀ
-20°C to 75°C (-4°F to 167°F)*
* For fuse performance under or above 25°C, consult fuse performance derating
charts in the Bussmann Division publication no. 3002, titled Selecting Protective
Devices (SPD)
Lockout/tagout provisions
The 35 mm DIN-Rail mount CCP2 is available in a variety of 30,
60 and 100 amp configurations to meet many application needs
including rotary operation.
•ꢀ
1/4” lock, direct use on switches without rotary mechanisms
requires a lock with a straight shank of sufficient length to engage
all poles
The switch-only versions of the 30, 60 and 100 A disconnects are
direct, drop-in replacements for the earlier models (noted by a
catalog number starting “CCP-”). The auxiliary contacts and PLC
remote fuse indicator are backwards compatible. The multi-wire lug
kits and terminal shrouds are not.
Minimum enclosure size per UL 98*
•ꢀ
30 and 60 A switch 10”x 8”x 6”(254 x 203 x 152 mm)
•ꢀ
100 A switch, 12” x 10” x 6” (305 x 254 x 152 mm)
Application flexibility is extended with an optional multi-wire lug
kit, featuring finger-safe shrouds, that provides three (30 and 60 A
switches) and six (100 A switches) additional wire ports on each pole
for power distribution applications.
* Smaller enclosures may be used at the discretion of the user, with adherence to
NEC minimum wire bend radius requirements.
Mounting**
•ꢀ
35 mm DIN-Rail
Other accessories include a PLC fuse monitor for open fuse
indication and NO/NC auxiliary contacts that easily integrate into
various monitoring systems.
**Switch is panel mount with flange handle cable operator.
Local open fuse indication minimum voltage
Front and side rotary operated versions are easily applied for
through-the-door or through the left or right side operation to
enhance safety.
•ꢀ
90 Vac, requires an open fuse to be in the CCP2 and the switch in
the ON position
Ratings
Accessories
•ꢀ
Volts
•ꢀ
Multi-wire lug kits with terminal shrouds
•ꢀ
347 Vac (1-pole switches)
•ꢀ
Selector and pistol handles for use with rotary operated switches
•ꢀ
600 Vac (2- and 3-pole switches)
•ꢀ
8 mm shafts for use with selector and pistol handles
•ꢀ
125 Vdc*
•ꢀ
Auxiliary contacts
•ꢀ
Amps
•ꢀ
PLC fuse monitor
•ꢀ
30 A
•ꢀ
NFPA 79 compliant handle
•ꢀ
60 A
•ꢀ
Flange handle rod and cable operators
•ꢀ
100 A
•ꢀ
SCCR
•ꢀ
200 kA RMS Sym.
•ꢀ
100 kA DC
Poles
•ꢀ
1-, 2- and 3-poles catalog number dependent
* Switch amp rating and installed fuse amp rating dependent, see catalog number
table for details.
Agency information
•ꢀ
UL 98 Listed, Guide WHTY, File E302370
•ꢀ
cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7,
File E302370
•ꢀ
RoHS compliant
•ꢀ
CE
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-3
Eaton.com/bussmannseries
11 — Disconnect switches
Features
•ꢀ
Uses UL Class CF time-delay or fast-acting CUBEFuse with Class
J electrical performance
•ꢀ
Extremely compact design at 25.4 mm (1 inch) wide per pole
•ꢀ
Amp rating rejection disconnects will not accept a CUBEFuse amp
rating greater than switch rating
•ꢀ
High 200 kA short-circuit current rating
•ꢀ
Disconnect rated to provide means for load isolation
•ꢀ
Full voltage rated at 347 Vac (1-pole switches) and 600 Vac (2- and
3-pole switches)
•ꢀ
125 Vdc* rated to meet specialized applications
•ꢀ
UL 98 Listed and suitable for branch circuit disconnect and branch
circuit protection with installed fuses
•ꢀ
Horsepower rated
•ꢀ
Open fuse indication:
•ꢀ Local open fuse indication light standard on each pole
•ꢀ Optional PLC fuse monitor for wired remote open fuse
indication by signaling a PLC and opening a contactor to
de-energize all phases, if required
•ꢀ
Additional open fuse indication can be provided by the indicating
time-delay CUBEFuse (6 to 100 A)
Finger-safe construction with 10 AWG (6 mm2) wire or larger
•ꢀ
•ꢀ
Built-in switch interlock prohibits removing or installing the fuse
while in the ON position
•ꢀ
Padlockable for lockout/tagout procedures with a 1/4” lock
Right front rotary operated CCP2 switch with PLC fuse monitor.
•ꢀ
Rotary operated versions provide for through-the-door and
through-the-side operation flexibility and enhanced safety with:
•ꢀ Right or left front operation
•ꢀ Right or left side operation
•ꢀ
Optional selector and pistol handles, and shafts available for use
with rotary operated versions
Rotary operating versions
•ꢀ
Multi-wire lug kits with terminal shrouds allow for power
distribution to multiple loads. Each lug has three (30 and 60 A
switches) or six (100 A switches) ports rated for single and dual
wires (see lug kits in accessories for details).
* Switch amp rating and installed fuse amp rating dependent, see catalog number
table for details.
Switch handle (ganged on 2- and
3-pole versions)
Open fuse
indicating light
Left front
Right front
Fuse holder
Uses clockwise handles
Uses clockwise handles
Fork terminal
Box lug terminal
1/4” Lockout/
tagout provision
Left side
Right side
Uses counterclockwise handles
Uses clockwise handles
11-4
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
30, 60 and 100 A switch catalog numbers
Max Hp rating (Vac)
Catalog no.
Poles Description/switch operation
Volts
SCCR
120
240
480
600
30 amp switches
CCP2-1-30CF
1
2
3
2
3
2
3
2
3
2
3
347 Vac/125 Vdc
600 Vac/125 Vdc
600 Vac
1-1/2
—
—
—
—
CCP2-2-30CF
Switch only
3
5
3
5
3
5
3
5
3
5
—
15
—
15
—
15
—
15
—
15
—
10
—
10
—
10
—
10
—
10
CCP2-3-30CF
—
CCP2R-2-30CF
CCP2R-3-30CF
CCP2RL-2-30CF
CCP2RL-3-30CF
CCP2S-2-30CF
CCP2S-3-30CF
CCP2SL-2-30CF
CCP2SL-3-30CF
60 amp switches
CCP2-1-60CF
600 Vac/125 Vdc
600 Vac
—
Right front rotary, clockwise
Left front rotary, clockwise
Right side rotary, clockwise
Left side rotary, counterclockwise
—
200 kA AC
100 kA DC
600 Vac/125 Vdc
600 Vac
—
—
600 Vac/125 Vdc
600 Vac
—
—
600 Vac/125 Vdc
600 Vac
—
—
1
2
3
2
3
2
3
2
3
2
3
347 Vac/125 Vdc*
600 Vac/125 Vdc*
600 Vac
3
—
—
—
—
—
10
—
10
—
10
—
10
—
10
CCP2-2-60CF
Switch only
—
—
—
—
—
—
—
—
—
—
7-1/2
CCP2-3-60CF
7-1/2 20
7-1/2
7-1/2 20
7-1/2
7-1/2 20
7-1/2
7-1/2 20
7-1/2
7-1/2 20
CCP2R-2-60CF
CCP2R-3-60CF
CCP2RL-2-60CF
CCP2RL-3-60CF
CCP2S-2-60CF
CCP2S-3-60CF
CCP2SL-2-60CF
CCP2SL-3-60CF
100 amp switches
CCP2-1-100CF
CCP2-2-100CF
CCP2-3-100CF
CCP2R-2-100CF
CCP2R-3-100CF
CCP2RL-2-100CF
CCP2RL-3-100CF
CCP2S-2-100CF
CCP2S-3-100CF
CCP2SL-2-100CF
CCP2SL-3-100CF
600 Vac/125 Vdc*
600 Vac
—
Right front rotary, clockwise
Left front rotary, clockwise
Right side rotary, clockwise
Left side rotary, counterclockwise
200 kA AC
100 kA DC
600 Vac/125 Vdc*
600 Vac
—
600 Vac/125 Vdc*
600 Vac
—
600 Vac/125 Vdc*
600 Vac
—
1
2
3
2
3
2
3
2
3
2
3
347 Vac/125 Vdc**
600 Vac/125 Vdc**
600 Vac
5
—
10
20
10
20
10
20
10
20
10
20
—
—
50
—
50
—
50
—
50
—
50
—
—
40
—
40
—
40
—
40
—
40
Switch only
—
—
—
—
—
—
—
—
—
—
600 Vac/125 Vdc**
600 Vac
Right front rotary, clockwise
Left front rotary, clockwise
Right side rotary, clockwise
Left side rotary, counterclockwise
200 kA AC
100 kA DC
600 Vac/125 Vdc**
600 Vac
600 Vac/125 Vdc**
600 Vac
600 Vac/125 Vdc**
600 Vac
* 125 Vdc for installed fuse amp ratings up to 40 A. 24 Vdc for installed fuse amp ratings from 45 to 60 A.
**125 Vdc for installed fuse amp ratings up to 80 A, 24 Vdc for installed fuse amp ratings from 90 to 100 A.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-5
Eaton.com/bussmannseries
11 — Disconnect switches
Box lug terminal conductor data
Dimensions – mm (in)
Switch (shown with optional terminal shrouds)
Wire
type
AWG
range Class
Torque
N•m (lb-in)
Quantity
30 and 60 A switches
4-6
3.95 (35)
2.26 (20)
3.39 (30)
Stranded, Class B
Single
to K
8-18
Stranded, Class B/C
Stranded, Class K
114
4.5
6-8
206
8.1
Dual
2.26 (20)
Stranded, Class B
to K
10-18
75°C Cu
76
3.0
10-18
4-18
6-18
4-18
6-18
Solid
Single/dual
Single
Twin†
2.26 (20)
3.39 (30)
83
3.3
50
2.0
75
3.0
Stranded, UL ferrule,
Class B/C
Single
Twin†
25
Stranded, UL ferrule,
Class K
2.82 (25)
1.0
30A Fuse
100 A switches
12-18
10
2.26 (20)
2.82 (25)
4.52 (40
5.08 (45)
6.21 (55)
5.08 (45)
2.26 (20)
3.95 (35)
4.52 (40)
2.26 (20)
2.82 (25)
2.26 (20)
2.26 (20)
3.39 (30)
5.08 (45)
2.26 (20)
3.39 (30)
2.26 (20)
75
3.0
89
3.5
8
Single
Stranded, Class B/C
4-6
1-3
4-12
12-18
10
60A Fuse
Dual
30 and 60 amp switches
Single
Stranded, UL ferrule,
Class B/C
1-8
75°C Cu
10-18
75
3.0
Twin†
Single/Dual
Single
Dual
6-9
50
2.0
25
10-18
8-18
1-7
Solid
148
5.8
1.0
240
Class K
9.5
3-10
8-18
1-7
Single
Class K, UL ferrule
100
3.9
6-18
Twin
† Two stranded conductors placed in one UL Listed twin ferrule.
Lineside and loadside fork terminal
•ꢀ
Fork terminal suitable for line, load or accessory connection, max.
30 A suitable for use with:
100 amp switches
•ꢀ 10-24 screw for 30 and 60 A switches
•ꢀ 1/4-28 screw for 100 A switches
Available Bussmann series fuses
Data
UL fuse
class
sheet
no.
Type/description
Volts
Indicating time-delay, Low-Peak™
CUBEFuse (6-100 A)
600 Vac/
300 Vdc
9000
Non-indicating time-delay, Low-Peak
CUBEFuse (1-100 A)
CF
Non-indicating fast-acting CUBEFuse
(1-100 A)
600 Vac/dc 2147
11-6
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Right front rotary switches (shown with optional terminal shrouds)
Left front rotary switches (shown with optional terminal shrouds)
114
114
4.5
4.5
206
8.1
206
8.1
99
3.9
99
3.9
83
3.3
83
3.3
101
4.0
101
4.0
76
3.0
76
3.0
30 A Fuse
30 A Fuse
99
3.9
99
3.9
89
3.5
89
3.5
60 A Fuse
60 A Fuse
30 and 60 amp switches
30 and 60 amp switches
101
4.0
101
4.0
148
5.8
148
76
76
3.0
5.8
3.0
240
9.5
240
9.5
100 106
3.9 4.2
100 106
3.9 4.2
100 amp switches
100 amp switches
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-7
Eaton.com/bussmannseries
11 — Disconnect switches
Left side rotary switches (shown with optional terminal shrouds)
Right side rotary switches (shown with optional terminal shrouds)
114
4.5
114
4.5
206
206
8.1
8.1
83
3.3
83
3.3
75
3.0
75
3.0
101
4.0
101
4.0
76
3.0
30 A Fuse
30 A Fuse
89
3.5
75
3.0
75
3.0
89
3.5
60 A Fuse
60 A Fuse
30 and 60 amp switches
30 and 60 amp switches
101
4.0
101
4.0
148
5.8
76
3.0
148
5.8
76
3.0
240
9.5
240
9.5
100
3.9
100
3.9
100 amp switches
100 amp switches
11-8
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
200 and 400 A switches
Poles
•ꢀ
1-, 2- and 3-poles catalog number dependent
Agency information
•ꢀ
UL 98 Listed, Guide WHTY, File E302370
•ꢀ
cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7,
File E302370
•ꢀ
RoHS compliant
Conductors/terminals
•ꢀ
See available lug table for size, type and torque information
400 A switch
200 A switch
Storage and operating temperature
•ꢀ
-20°C to 75°C (-4°F to 167°F)*
* For fuse performance under or above 25°C, consult fuse performance derating
charts in the Bussmann Division publication no. 3002, titled Selecting Protective
Devices (SPD)
Lockout/tagout provisions using 1/4” lock
•ꢀ
Integral with switch handle
•ꢀ
Front rotary operating mechanism
With side rotary accessory
With front rotary accessory
•ꢀ
Rotary pistol handles
•ꢀ
Flange rod and cable operators
Catalog no.
Poles
Amps
Description
Minimum enclosure size
CCP2-1-200CF
CCP2-2-200CF
CCP2-3-200CF
CCP2-1-400CF
CCP2-2-400CF
CCP2-3-400CF
1
2
3
1
2
3
•ꢀ
200 A switch 16 x 12 x 6” (405 x 305 x 150 mm)
200
•ꢀ
400 A switch 24 x 16 x 8 (610 x 405 x 200 mm)
Switch only
Mounting
•ꢀ
Panel mount
400
Local open fuse indication minimum voltage
Description
•ꢀ
90 Vac, requires an open fuse to be in the CCP2 and the switch in
the ON position
The Bussmann series 200 and 400 A Compact Circuit Protector
(CCP2) fused disconnect switches utilize the finger-safe UL Class CF
time-delay CUBEFuse with Class J electrical performance. With up
to a 69 percent smaller footprint than a traditional fusible solution,
these switches provide a high 200 kA SCCR to help improve panel
and assembly SCCR.
Accessories
•ꢀ
Lugs and lug kits with terminal shrouds
•ꢀ
Pistol handles for use with rotary operated switches
•ꢀ
NFPA 79 compliant handle
The panel mount 200 and 400 A CCP2 switches are available with
a variety of accessories to meet many application needs including
rotary and flange handle operation.
•ꢀ
12 mm shafts for use with selector and pistol handles
•ꢀ
Auxiliary contacts
•ꢀ
Rotary operators are available for front or side (right or left)
operation. Front rotary operators are for three-pole switches only
while the side operator may be applied to the right or left side of 1-,
2- and 3-pole units.
Flange handle rod and cable operators
Other accessories include lugs, terminal shrouds, rotary pistol
handles, flange rod and cable operating mechanisms, NO/NC
auxiliary contacts that easily integrate into various monitoring
systems and a handle extension.
Front and side rotary operated versions are easily applied for
through-the-door or through the left or right side operation to
enhance safety.
Ratings
•ꢀ
Volts
•ꢀ
347 Vac (1-pole) 600 Vac (2- and 3-pole)
•ꢀ
Amps
•ꢀ
200 A
•ꢀ
400 A
•ꢀ
SCCR
•ꢀ
200 kA RMS Sym.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-9
Eaton.com/bussmannseries
11 — Disconnect switches
Features
•ꢀ
•ꢀ
Standard local open fuse indication light on each pole speeds
troubleshooting
•ꢀ
Uses UL Class CF time-delay CUBEFuse with Class J electrical
performance
Built-in switch interlock prevents inserting or removing fuse while
in the ON position
•ꢀ
Amp rating rejection feature will not accept a CUBEFuse amp
ratings greater than switch rating
•ꢀ
•ꢀ
Padlockable for lockout/tagout procedures with a 1/4” lock
•ꢀ
High 200 kA short-circuit current rating
Front and side rotary operator accessories provide for through-
the-door and through-the-side operation flexibility and enhanced
safety
•ꢀ
Disconnect rated to provide means for load isolation
•ꢀ
Full voltage rated at 600 Vac
•ꢀ
UL 98 Listed and suitable for branch circuit disconnect and branch
circuit protection with installed fuses
•ꢀ
•ꢀ
Optional pistol handles and shafts available for use with rotary
operator accessories
•ꢀ
Horsepower rated (see table below)
Multi-wire lug kits with terminal shrouds allow for power
distribution to multiple loads.
Catalog numbers and horsepower ratings
Max Hp rating (Vac)
Catalog no.
Poles
Description
Volts AC
SCCR
240
480
600
200 amp switches
CCP2-1-200CF
CCP2-2-200CF
CCP2-3-200CF
400 amp switches
CCP2-1-400CF
CCP2-2-400CF
CCP2-3-400CF
1
2
3
347
600
—
10
50
—
—
100
—
—
150
Switch only
200 kA
1
2
3
347
600
—
—
100
—
—
200
—
—
250
Switch only
200 kA
Available lugs, conductor ratings and terminal torques
Lugs per
Wire range
AWG (mm2)
Wire type/ Conductor torque Lug mounting screw
Catalog no.
200 A switches
CCP2-L2-1
Description
cat. no.
temp.
N•m (lb-in)
torque N•m (lb-in)
Stainless steel lug
Aluminum lug*
1
1
3
3
350-4 (185-25)
350-4 (185-25)
2-14 (35-2.5)
6-14 (16-2.5)
Cu 75°C
20.3 (180)
28.2 (250)
7.9 (70)
0.9 (8)
13.5 (120)
10.8 (95)
10.8 (95)
CCP2-L2-1A
Cu/Al 75°C
Cu/Al 75°C
Cu/Al 75°C
CCP2-MW2-3 3-port multi-wire terminal with shroud*
CCP2-MW2-6 6-port multi-wire terminal with shroud*
2.8 (25)
* These lugs also accept 1/4” quick connect control wire terminals. Order catalog number CCP2-CWK2 (package of 12 terminals).
400 A Switches
CCP2-L4-1
CCP2-L4-1A
CCP2-L4B-3
CCP2-L4B-3A Aluminum lug kit with shroud
CCP2-L6-3
Stainless steel lug
Aluminum lug
Stainless steel lug kit with shroud
1
1
3
3
3
3
500-3 (240-35)
500-3 (240-35)
750-500 (400-240)
750-500 (400-240) Cu/Al 75°C
(2) 500-2 (240-35) Cu 75°C
(2) 500-2 (240-25) Cu/Al 75°C
Cu 75°C
Cu/Al 75°C
Cu 75°C
42.0 (375)
42.0 (375)
57.0 (500)
62.0 (550)
42.0 (375)
2-port stainless steel lug kit with shroud
2-port aluminum lug kit with shroud
22.0 (200)
CCP2-L6-3A
42.0 (375)
10-14 = 3.9 (35)
8 = 4.5 (40)
4-6 = 5.0 (45
1/0-2 = 5.6 (50)
CCP2-MW6-6 6-port multi-wire terminal with shroud
3
1/0-14 (50-2.5)
Cu/Al 75°C
Accessories
Switch
amps
Catalog no.
CCP2-TS2-3
CCP2-PB2
CCP2-RM2
CCP2-TS6-3
CCP2-PB6
CCP2-RM4
CCP2-SM
Description
3-pole terminal shroud
Phase barriers (pack of 2)
200
Front rotary operator* (3-pole switch only)
3-pole terminal shroud
400
Phase barriers (pack of 2)
Front rotary operator* (3-pole switch only)
200/400 Side rotary operator* (1-, 2- or 3-pole switches)
* Complete installation requires pistol handle and shaft, order separately.
11-10
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
200 amp switch dimensions — mm (in)
Ø 5.0 (0.2) Thru
Ø 9.2 (0.4) 5.4 (0.2)
133.2 (5.2)
104.7 (4.1)
160.4 (6.3)
119.7 (4.7)
85.4 (3.4)
34.9 (1.4) 34.9 (1.4)
56.0
(2.2)
55.2
(2.2)
152.4
(6.0)
139.7
(5.5)
177.9
(7.0)
Front rotary
mechanism
accessory
Side rotary
mechanism
accessory
CCP2-SM
CCP2-RM2
34.9 (1.4) 34.9 (1.4)
119.7
(4.7)
87.3
(3.4)
335.9
(13.2)
3-pole terminal
shroud accessory
CCP2-TS2-3
104.8
(4.1)
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-11
Eaton.com/bussmannseries
11 — Disconnect switches
400 amp switch dimensions — mm (in)
Ø 5.0 (0.2) Thru
Ø 14.0 (0.5) 5.9 (0.2)
159.3 (6.3)
130.8 (5.1)
175.8 (6.9)
132.8 (5.2)
102 (4.0)
43.6 (1.7) 43.6 (1.7)
56.0
(2.2)
98.8
(3.9)
225.0
(8.8)
214.4
(8.4)
257
(10.1)
Front rotary
mechanism
accessory
Side rotary
mechanism
accessory
CCP2-SM
CCP2-RM4
43.6 (1.7) 43.6 (1.7)
132.9
(5.2)
101.4
(4.0)
365.0
(14.3)
3-pole terminal
shroud accessory
CCP2-TS6-3
139.2
(5.4)
11-12
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Installed on CCP2-3-xx
30, 60 and 100 A switch multi-wire lug kits
Catalog numbers
•ꢀ
CCP2-MW1-3 (30 and 60 A switches only)
•ꢀ
CCP2-MW1-6 (100 A switches only)
Description
The multi-wire lug kits permit expanding each box lug terminal on
the switch into a three-port (30 and 60 A switches) or six-port (100 A
switches) terminal for power distribution applications.
Each multi-wire lug kit comes with three lugs and three terminal
shrouds. Shrouds provide finger-safe protection when properly
installed.
Lugs may be mounted on either the loadside or lineside to meet
various application needs.
Ports on any one lug accept any conductor combination listed, e.g.,
one of the ports may have dual 14 AWG wires and the other two
ports single 10 AWG wires.
Multi-wire lugs mount in switch box lug terminals to provide three
additional wire ports per pole. Lugs can be mounted on the switch
lineside or loadside. Each multi-wire lug kit comes with three lugs
and three shrouds.
Ratings
•ꢀ
Volts 600 V
•ꢀ
Amps
•ꢀ 60 A max (
CCP2-MW1-3)
Wire insulation strip lengths
•ꢀ 100 A max (
CCP2-MW1-6)
1/8” Allen
head screw
1/8” Allen
head screw
•ꢀ
SCCR 200 kA
Agency information
1 = 11/16”
•ꢀ
UL Recognized, Guide WHTY2, File E302370
1 = 11/16”
2 = 1-1/8”
•ꢀ
RoHS compliant
2 = 1-1/8”
3 = 1-9/16”
Storage and operating temperature
3 = 1-9/16”
•ꢀ
-20°C to 75°C (-4°F to 167°F)
Multi-wire lug conductor information
Strip back wire insulation to the lengths as indicated in the
illustration above and the table below.
•ꢀ
75°C Cu/AL
•ꢀ
AWG size and quantity per port - see table below
Lug port
Strip wire insulation back (inch)
1
2
3
11/16
1-1/8
AWG
Torque
Type range Class
Quantity
N•m (lb-in)
4-6
8
3.95 (35)
2.82 (25)
2.26 (20)
2.26 (20)
2.82 (25)
2.26 (20)
1-9/16
Cu/Al
Stranded, Class B/C
Single
10-14 Stranded, Class B/C
Single/dual*
Single
10-14 Solid
8
Cu
UL ferrule, Class B to K Single/twin†
10-14
* Dual wire to be same size and type.
† Two stranded conductors placed in one UL Listed twin ferrule.
CCP2 box lug torque for multi-wire lugs
•ꢀ
30/60 A switch lug, 4.52 N•m (40 lb-in)
•ꢀ
100 A switch lug, 5.09 N•m (45 lb-in)
Wiring versatility is provided by single/dual rated box lug terminals
on the switch, or by the three-port or six-port multi-wire lug kits that
are also single/dual wire rated.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-13
Eaton.com/bussmannseries
11 — Disconnect switches
200 and 400 A switch multi-wire lug kits
Installed on CCP2-3-xx
Catalog numbers
•ꢀ
CCP2-MW2-3 ( 3-port, 200 A switches only)
•ꢀ
CCP2-MW2-6 (6-port, 200 A switches only)
•ꢀ
CCP2-MW6-6 (6-port, 400 A switches only)
Description
The multi-wire lug kits permit expanding the terminal on the switch
into a three-port (200 A switches) or six-port (200 and 400 A
switches) terminal for power distribution applications.
Each multi-wire lug kit comes with three lugs and a 3-pole terminal
shroud. The shroud provides finger-safe protection when properly
installed.
3- and 6-port multi-wire lugs mounted on 200 A switches
Lugs can only be mounted on loadside to meet application needs.
Ports on any one lug accept any conductor combination listed, e.g.,
one of the ports may have dual 14 AWG wires and the other two
ports single 10 AWG wires.
Ratings
•ꢀ
Volts 600 V
•ꢀ
Amps
•ꢀ 225 A max (
•ꢀ 600 A max (
SCCR 200 kA
CCP2-MW2-3 and CCP2-MW2-6)
CCP2-MW6-6)
•ꢀ
Agency information
6-port multi-wire lugs mounted on 400 A switches
•ꢀ
UL Recognized, Guide WHTY2, File E302370
•ꢀ
RoHS compliant
Multi-wire lugs mount on the switch terminals to provide three or
six additional wire ports per pole. Lugs to be mounted only on the
loadside. Each multi-wire lug kit comes with three lugs, a shroud and
mounting hardware.
Storage and operating temperature
•ꢀ
-20°C to 75°C (-4°F to 167°F)
Multi-wire lug conductor information
Wire insulation strip lengths
•ꢀ
75°C Cu/AL
Straight blade
head screw
•ꢀ
AWG size and quantity per port - see table below
4 mm Allen
head screw
4 mm Allen
head screw
1 = 3/4 to 7/8”
2 = 1-3/8 to 1-1/2”
3 = 2 to 2-1/8”
1 = 3/8 to 1/2”
2 = 3/4 to 7/8”
3 = 1-1/4 to 1-3/8”
1 = 3/8 to 1/2”
2 = 3/4 to 7/8”
3 = 1-1/4 to 1-3/8”
AWG
Torque
N•m (lb-in)
Type range Class
Quantity
4-6
3.95 (35)
2.82 (25)
2.26 (20)
2.26 (20)
2.82 (25)
2.26 (20)
CCP2-MW6-6
CCP2-MW2-6
CCP2-MW2-3
Cu/Al
Stranded, Class B/C
Single
8
Strip back wire insulation to the lengths indicated in the illustration
above and the table below.
10-14 Stranded, Class B/C
Single/dual*
Single
10-14 Solid
8
Cu
Wire insulation strip length (inch)
UL ferrule, Class B to K Single/twin†
Lug kit
Lug port 1
3/8 to 1/2
3/4 to 7/8
Lug port 2
Lug port 3
1-1/4 to 1-3/8
2 to 2-1/8
10-14
CCP2-MW2-3
CCP2-MW2-6
CCP2-MW6-6
* Dual wire to be same size and type.
† Two stranded conductors placed in one UL Listed twin ferrule.
3/4 to 7/8
1-3/8 to 1-1/2
11-14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Pistol handles —short and long
Selector and pistol handles
Catalog symbol
Selector handles
•ꢀ
CCP2-H4X-_1 (selector handle for 30, 60 and 100 A switches)
•ꢀ
CCP2-H4X-_2 (pistol handle for 30, 60 and 100 A switches)
•ꢀ
CCP2-H4X-_3 (short pistol handle for 200 and 400 A switches)
•ꢀ
CCP2-H4X-_4 (long pistol handle for 200 and 400 A switches)
Description
Selector and pistol handles are used with rotary operated switches.
Pistol handles for 200 and 400 A switches come in short and long
versions. All handles are available in black/gray and red/yellow
colors, and clockwise/counterclockwise operating modes. Front and
right side operated switches use clockwise handles while left side
operated switches use counterclockwise handles.
Agency information
•ꢀ
UL Listed, Guide DIHS/DIHS7, File E140305
•ꢀ
•ꢀ
•ꢀ
Type 1, 4X and 12
RoHS compliant
CE
Installation requires an 8 mm shaft for 30, 60 and 100 A switches
and a 12 mm shaft for 200 and 400 A switches (ordered separately).
Storage and operating temperature
•ꢀ
-20°C to 75°C (-4°F to 167°F)
Each handle is rated Type 1, 4X and 12, and accepts up to three (3)
1/4” diameter shank locks for lockout/tagout in the OFF position.
They can also be field configured for lock-on and are defeatable.
Only the clockwise operating handles in combination with front
rotary operating switches provide a door interlock means to ensure
the enclosure door remains shut during lockout/tagout or lock-on.
Rotary handles mounted on the enclosure’s left or right side do NOT
provide a door interlock means.
See the catalog number table below for applicable rotary switch,
handle and shaft combinations.
Handles and shafts for 30, 60 and 100 A switches
For catalog no.
Description/operation
Order handle cat. no.
Order either 8 mm shaft cat. no.
CCP2R-(pole)-30CF
CCP2R-(pole)-60CF
CCP2R-(pole)-100CF
CCP2RL-(pole)-30CF
CCP2RL-(pole)-60CF
CCP2RL-(pole)-100CF
CCP2S-(pole)-30CF
CCP2S-(pole)-60CF
CCP2S-(pole)-100CF
Right front rotary, clockwise
CCP2-H4X-B1 (selector, black/grey)
CCP2-H4X-R1(selector, red/yellow)
CCP2-H4X-B2 (pistol, black/grey)
CCP2-H4X-R2 (pistol, red/yellow)
Left front rotary, clockwise
Right side rotary, clockwise
CCP2-SH1-290 (11.5”/290 mm)
CCP2-SH1-490 (19.3”/490 mm)
CCP2SL-(pole)-30CF
CCP2SL-(pole)-60CF
CCP2SL-(pole)-100CF
CCP2-H4X-B1L (selector, black/grey)
CCP2-H4X-R1L (selector, red/yellow)
CCP2-H4X-B2L (pistol, black/grey)
CCP2-H4X-R2L (pistol, red/yellow)
Left side rotary,
counterclockwise
Handles and shafts for 200 and 400 A switches
Order front
rotary
mechanism
cat. no.
Order right/
left side rotary
mechanism
cat. no.
Order left side counterclockwise
Order either 12
Order front/right side clockwise handles (use only with CCP2-SM) mm shaft cat.
For catalog no.
handle cat. no.
cat. no.
no.
CCP2-H4X-B3 (short - black/grey) CCP2-H4X-B3L (short - black/grey)
CCP2-H4X-R3 (short - red/yellow) CCP2-H4X-R3L (short - red/yellow)
CCP2-(poles)-200CF
CCP2-RM2*
CCP2-RM4*
CCP2-SH2-225
(8.9”/225 mm)
CCP2-SM
CCP2-H4X-B4 (long - black/grey)
CCP2-H4X-R4 (long - red/yellow)
CCP2-H4X-B4L (long - black/grey)
CCP2-H4X-R4L (long - red/yellow)
CCP2-SH2-425
(16.7”/425 mm)
CCP2-(poles)-400CF
* For three-pole switches only.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-15
Eaton.com/bussmannseries
11 — Disconnect switches
Handle dimensions — mm (in)
Handle shafts
Selector for 8 mm shafts
8 mm shafts
28
(1.1)
Ø7
(0.3)
85
(3.3)
71
(2.8)
Short pistol for 8 mm and 12 mm shafts
12 mm shafts
33
(1.3)
85
(3.3)
Ø7
(0.3)
ON
OFF
129
(5.1)
71
(2.8)
Catalog numbers
•ꢀ
CCP2-SH1-290 (8 mm, 290 mm long)
Long pistol for 12 mm shafts
•ꢀ
CCP2-SH1-490 (8 mm, 490 mm long)
85
34
(3.3)
(1.3)
•ꢀ
CCP2-SH2-225 (12 mm, 225 mm long)
Ø7
(0.3)
•ꢀ
CCP2-SH2-425 (12 mm, 425 mm long)
68
96
(3.8)
(2.7)
Description
85
(3.3)
71
(2.8)
Square shafts available in:
28
(1.1)
179
(7.0)
•ꢀ
8 mm square by 290 and 490 mm lengths for 30, 60 and 100 A
switches
71
(2.8)
•ꢀ
12 mm square by 225 and 425 mm lengths for 200 and 400 A
switches
All shafts are indexed to ensure handle/switch orientation for correct
operation. Shafts are to be cut to length when installed.
NFPA 79 compliant handles
Catalog numbers
•ꢀ
CCP2-NFPA-1
(8 mm shafts for 30-100 A switches)
•ꢀ
CCP2-NFPA-2
(12 mm shafts for 200 and 400 A switches)
Description
NFPA 79 handles mount on the shaft of
front rotary operated switch installations and
provide a lockout means independent of the
door position.
11-16
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Flange handle rod and cable operators
Catalog no.
Description
Rating
30, 60 and 100 amp switches
CCP2-FLR1
Rod operator with painted handle
Type 1, 3R, 12
Type 4X
CCP2-FLR1X
Rod operator with chrome handle
36” Cable with painted handle
36” Cable with chrome handle
60” Cable with painted handle
60” Cable with chrome handle
120” Cable with painted handle
CCP2-FLC1-36
CCP2-FLC1-36X
CCP2-FLC1-60
CCP2-FLC1-60X
CCP2-FLC1-120
Type 1, 3R, 12
Type 4X
Type 1, 3R, 12
Type 4X
Type 1, 3R, 12
Type 4X
Flange rod operator kit for 30, 60 and 100 A switches.
CCP2-FLC1-120X 120” Cable with chrome handle
200 and 400 amp switches
CCP2-FLR2
Rod operator with painted handle
Rod operator with chrome handle
36” Cable with painted handle
36” Cable with chrome handle
60” Cable with painted handle
60” Cable with chrome handle
120” Cable with painted handle
Type 1, 3R, 12
Type 4X
CCP2-FLR2X
CCP2-FLC2-36
CCP2-FLC2-36X
CCP2-FLC2-60
CCP2-FLC2-60X
CCP2-FLC2-120
Type 1, 3R, 12
Type 4X
1, 3R, 12
Type 4X
Type 1, 3R, 12
Type 4X
CCP2-FLC2-120X 120” Cable with chrome handle
Description
Flange rod operator kit for 200 and 400 A switches.
Flange rod and cable operators for use on 2- and 3-pole CCP2
switches (cannot be used with 2- or 3-pole 30, 60 or 100 amp
switches already having a front or side rotary operating mechanism).
Handles are available in painted versions with NEMA 1, 3R and 12
ratings or chrome versions with a NEMA 4X rating.
Cable operators are available with 36, 60 and 120 inch cable
lengths.
Agency information
•ꢀ
Type 1, 4X and 12
•ꢀ
RoHS compliant
Storage and operating temperature
•ꢀ
-20°C to 75°C (-4°F to 167°F)
Packaging
Flange cable operator kit for 30, 60 and 100 A switches.
•ꢀ
Each handle is packaged individually as a kit
Flange cable operator kit for 200 and 400 A switches.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-17
Eaton.com/bussmannseries
11 — Disconnect switches
Front rotary mechanisms for 200 and 400 A switches
Phase barriers
Catalog numbers
•ꢀ
CCP2-PB2
(3-pole 200 A switches)
•ꢀ
CCP2-PB6
(3-pole 400 A switches)
Description
Phase barrier kit with two phase
barriers for isolation between the
lugs on 3-pole 200 and 400 A
switches.
Catalog numbers
Packaged individually.
•ꢀ
CCP2-RM2 (3-pole 200 A switches)
•ꢀ
CCP2-RM4 (3-pole 400 A switches)
Handle extension
Description
Front rotary mechanisms for through-the-door operation and install
on the front of 3-pole switches only. These units provide at-switch
lockout/tagout capability for enhanced safety. Complete installation
requires installing pistol handle (short or long) and 12 mm shaft.
Packaged individually.
Side rotary mechanism for 200 and 400 A switches
Catalog number
•ꢀ
CCP2-HEX (1-, 2- and 3-pole 200 and 400 A
switches)
Description
A handle extension to provide additional leverage for operating the
switch in installations that do not have rotary mechanisms or flange
operators installed. Does not mount on switch, provision for tether
provided.
Packaged individually.
Catalog number
•ꢀ
CCP2-SM
(1-, 2- or 3-pole 200 and 400 A switches)
Description
Side rotary mechanism for through-the-side operation and installs
on the left or right side (right side installation recommended) of any
1-, 2- or 3-pole 200 and 400 A switch. The side rotary mechanism
does not provide for door interlock nor local lockout/tagout capability.
Complete installation requires installing pistol handle (short or long)
and 12 mm shaft.
Packaged individually.
Terminal shrouds
Catalog numbers
•ꢀ
CCP2-TS2-3
(3-pole 200 A switches)
•ꢀ
CCP2-TS6-3
(3-pole 400 A switches)
Description
3-pole shroud kit with
shields for isolating the
lugs on 3-pole 200 and
400 A switches.
Packaged individually.
11-18
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Installed on a CCP2-3-xx
Auxiliary contacts for 30, 60 and 100 A switches
Note: CCP2-AUX and CCP2-AUX-100 CANNOT be mounted on the
right front and right side rotary operated versions, nor installed with
the flange handle rod or cable operator.
Catalog numbers
•ꢀ
CCP2-AUX (30 and 60 A switches)
•ꢀ
CCP2-AUX-100 (100 A switches)
Description
NO+NC contact output to indicate the
switching mechanism status on the
CCP2. A single unit can be mounted
on any 1-, 2- or 3-pole CUBEFuse
CCP2 switch and the left front/left side
rotary operated switches.
Ratings
•ꢀ
240 Vac max
•ꢀ
5 A max
•ꢀ
NC/NO contacts are closed/open when the CCP2 switch is in the
“ON” position (closed)
Catalog no.
Switch Description
Max per CCP2*
Ratings
30/60 A
only
CCP2-AUX
Auxiliary contacts
N/NC for switch
status
1 per CCP2
(1-, 2- or 3-pole)
5 A / 240 Vac
100 A
only
Dimensions — in
CCP2-AUX-100
1.8
* The CCP2-AUX CANNOT be mounted on the right front and right side rotary
operated versions, nor installed with the flange handle rod or cable operator.
De-energize all circuits and follow all prescribed safety procedures before
installing or removing the auxiliary contact device.
Agency information
•ꢀ
UL 98 Recognized, Guide WHTY2, File E155130
2.6
STRIP
•ꢀ
cURus to Canadian Standard 22.2 No. 4-04
1.9
33 NO
41 NC
34 NO
42 NC
•ꢀ
Finger-safe in installed state
•ꢀ
RoHS compliant
•ꢀ
CE
Wiring
.190
3.7
16-20 AWG (1.5 to 0.5 mm2) single and dual stranded wire
•ꢀ
0.3
20 AWG (1.5 mm2) single and dual solid wire
CCP2-AUX
•ꢀ
•ꢀ
Torque 0.56 N•m (5 lb-in)
•ꢀ
Use only 75°C Cu wire
1.8
Packaging
•ꢀ
CCP2-AUX and CCP2-AUX-100 are packaged individually
Installation technique
•ꢀ
Mounts on the CCP2’s right side ONLY and mechanically
interlocks with the CCP2 switch handle with provided hardware.
The CCP2-AUX and CCP2-AUX-100 CANNOT be mounted on the
right front and right side rotary operated versions, nor installed
with the flange handle rod or cable operator.
2.9
33 NO
34 NO
42 NC
STRIP
2.2
Storage and operating temperature
41 NC
•ꢀ
-20°C to 75°C (-4°F to 167°F)
.190
3.7
0.3
CCP2-AUX-100
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-19
Eaton.com/bussmannseries
11 — Disconnect switches
Auxiliary contacts for 200 and 400 A switches
Installed on a CCP2-3-xx
Note: CCP2-AUX-S CANNOT be mounted on the same side as the
side rotary mechanism CCP2-SM or the right side if a flange handle
rod or cable operator is installed.
Catalog number
•ꢀ
CCP2-AUX-S (200 and 400 A switches)
Description
NO+NC contact output to indicate the
switching mechanism status on the
CCP2. A single unit can be mounted
on either side of any 1-, 2- or 3-pole
switch (cannot be mounted on the
same side as the CCP2-SM side
rotary mechanism or the right side if a
flange handle rod or cable operator is
installed).
Ratings
•ꢀ
240 Vac max
•ꢀ
5 A max
•ꢀ
NC/NO contacts are closed/open when the CCP2 switch is in the
“ON” position (closed)
Catalog no. Switch
Description
Max per CCP2*
Ratings
Auxiliary contacts
NO+NC for switch
status
200 and
CCP2-AUX-S
1 per CCP2
(1-, 2- or 3-pole)
5 A / 240 Vac
400 A
* The CCP2-AUX-S CANNOT be mounted on the same side where the side rotary
mechanism (CCP2-SM) is installed.
De-energize all circuits and follow all prescribed safety procedures before
installing or removing the auxiliary contact device.
Agency information
•ꢀ
UL 98 Recognized, Guide WHTY2, File E155130
•ꢀ
cURus to Canadian Standard 22.2 No. 4-04
•ꢀ
Finger-safe in installed state
•ꢀ
RoHS compliant
Wiring
16-20 AWG (1.5 to 0.5 mm2) single and dual stranded wire
•ꢀ
20 AWG (1.5 mm2) single and dual solid wire
•ꢀ
•ꢀ
Torque 0.56 N•m (5 lb-in)
•ꢀ
Use only 75°C Cu wire
Installation technique
•ꢀ
Mounts on either side of the 200 and 400 A switches and
mechanically interlocks with the switch’s handle with provided
hardware. The CCP2-AUX-S CANNOT be mounted on the same
side with an installed CCP2-SM side rotary mechanism, or the
flange cable/rod operating mechanisms.
Storage and operating temperature
•ꢀ
-20°C to 75°C (-4°F to 167°F)
Packaging
•ꢀ
Packaged individually.
11-20
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Agency information
PLC fuse monitor for 30, 60 and 100 A switches
•ꢀ
UL 98 Recognized, Guide WHTY2, File E155130
cURus to Canadian Standard 22.2 No. 4-04
Catalog numbers
•ꢀ
•ꢀ
CCP2-PLC-IND
(30/60 A switches)
Local indication
•ꢀ
CCP2-PLC-100
(100 A switches)
•ꢀ
Two distinct LEDs indicate unit power (green) and open fuse
(red). Open fuse LED is resettable upon fuse replacement and the
actuating the reset switch
Description
A resettable three-phase
Wiring
fuse monitor that integrates
•ꢀ
For power, signal and ground connections use shielded twisted
with the I/O card in a
pair 22-24 AWG (0.34-0.25 mm2) 300 V rated wire
Programmable Logic
Controller (PLC). A single
unit can be mounted on any
Installation technique
1-, 2- or 3-pole CUBEFuse
•ꢀ
Mounts on the left side ONLY of the CCP2 and mechanically
CCP2 switch up to 100 A
interlocks with the CCP2 switch handle with hardware provided.
The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on
the left front/left side rotary operated versions or if a multi-wire
lug kit is installed or if the flange handle rod operator is installed.
and the left front/ left side
rotary operated switches.
A single unit monitors up to three phases. When used on 1- and
2-pole switches unused conductor(s) are removed after installation.
The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on
the left front/left side rotary operated versions or if a multi-wire lug
kit is installed or if a multi-wire lug kit is installed, or if the flange
handle rod operator is installed.
IP20 rating — yes
Storage and operating temperature
•ꢀ
-20°C to 75°C (-4°F to 167°F)
Ratings
PLC programming
•ꢀ
Signal output to PLC*
•ꢀ
The CCP2-PLC-IND or CCP2-PLC-100 signal line is designed
•ꢀ +24 Vdc, 10 mA max
to provide a digital input to a PLC I/O card. In this case, a
Programmable Logic Control program must be written to properly
interpret the input signal to the PLC. The PLC program should
check for consecutive high signals before taking action on a
critical process.
•ꢀ
Output signals
•ꢀ Digital 0 Vdc (low), 24 Vdc max (high)
•ꢀ 0 Vdc Low – fuse is good
•ꢀ 24 Vdc High – fuse has opened
* When the fuse opens, the output signal is sent high and will remain high until
the unit is reset.
Emissions and immunity testing
•ꢀ
IEC 60947-1: Voltage Switchgear and Control Gear
•ꢀ
IEC 61000-6-2: Electromagnetic Compatibility (EMC)
•ꢀ IEC 61000-4-2: Electrostatic Discharge Immunity - Test at level
3 (6 kV-Contact Discharge) and level 2 (4 kV-Air Discharge)
•ꢀ IEC 61000-4-3: Electromagnetic Compatibility - Radiated, Radio-
frequency, Electromagnetic Field Immunity test at level x (20
V/m)
•ꢀ IEC 61000-4-4: Electromagnetic Compatibility - Testing and
Measurement Techniques at level 3 (± 2kV - Power Port and
±1 kV - I/O Ports)
•ꢀ IEC 61000-4-5: Electromagnetic Compatibility - Surge Immunity
test at level 4 (±4 kV)
•ꢀ IEC 61000-4-6: Immunity to Conducted Disturbances at level 3 (10 V)
Signal
Min.
Max per
CCP2**
output circuit
Catalog no.
Switch Description
to PLC
volts
Wired
30/60 A
CCP2-PLC-IND
remote fuse 1 per CCP2
only
24 Vdc/
10 mA
indication
for PLC
applications
(1, 2- or
3-pole)
100 Vac
100 A
only
CCP2-PLC-100
**The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on the left front/
left side rotary operated versions or if a multi-wire lug kit is installed.
De-energize all circuits and follow all prescribed safety procedures before installing
or removing the CCP2-PLC-IND or CCP2-PLC-100.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-21
Eaton.com/bussmannseries
11 — Disconnect switches
Installed on a CCP2-3-xx
PLC wiring schematic
PLC power supply
PLC fuse monitor
+24 Vdc
+24 Vdc
0 Vdc/Gnd
0 Vdc/Gnd
Signal
10 mA max.
The PLC fuse monitor needs
to be powered by the same
+24 Vdc and ground
(0 Vdc/Gnd return)
terminals that feed the
PLC input card.
If it is not, it may
improperly signal.
If feeding multiple
+24 Vdc
PLC fuse monitors from
different power supplies,
there must be multiple
input cards being powered
by those same power
supplies as well.
0 Vdc/Gnd
PLC
CCP2-PLC-IND mounted on a 3-pole switch and using the fork
terminals. When mounted on a 2- or 1-pole switch, remove unused
leads.
input card
Note: the CCP2-PLC-IND CANNOT be mounted on the left front/left
side rotary operated versions or if the multi-wire lug kit is installed or
if the flange handle rod operator is installed.
Dimensions — in
1.8
Pin interlocks with
CCP2 switch handle
2.6
1.9
3.7
0.3
30 and 60 A CCP
2.0
Pin interlocks with
CCP2 switch handle
2.9
2.2
0.3
3.7
100 A CCP
11-22
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Ordering a complete switch installation
30 and 60 A CCP2 switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Switch (used alone or with flange cable or flange rod handles)
CCP2-1-30CF
1
2
3
1
2
3
CCP2-2-30CF
CCP2-3-30CF
CCP2-1-60CF
CCP2-2-60CF
CCP2-3-60CF
30
60
And
Flange handle rod
operator
Description — 3-pole switches only
Rating
1, 3R and 12
4X
CCP2-FLR1-21
CCP2-FLR1-21X
Red/black painted handle
Chrome handle
Or
Flange handle cable
operator
Description - 3-pole switches only, cannot be used with side or
front rotary mechanisms
Rating
Type 1, 3R, 12
Type 4X
CCP2-FLC1-36
CCP2-FLC1-36X
CCP2-FLC1-60
CCP2-FLC1-60X
CCP2-FLC1-120
CCP2-FLC1-120X
36” cable, red/black painted handle
36” cable, chrome handle
60” cable, red/black painted handle
60” cable, chrome handle
Type 1, 3R, 12
Type 4X
120” cable, red/black painted handle
120” cable, chrome handle
Type 1, 3R, 12
Type 4X
Multi-wire lug kits
Description
CCP2-MW1-3
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
And
Terminal shrouds
Description
CCP2-TS1-3
Pack of 3
Description — mounts on right side, cannot be used with flange handle rod or
cable operator
Auxiliary contacts
CCP2-AUX
NO/NC, 5 A / 240 V
Description — mounts on left side, cannot be used with flange handle rod
operator
PLC fuse monitor
CCP2-PLC-IND
Signal output 24 Vdc / 10 mA
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-23
Eaton.com/bussmannseries
11 — Disconnect switches
Ordering a complete switch installation
30 and 60 A CCP2 clockwise rotary switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Right front rotary
CCP2R-2-30CF
2
3
2
3
30
60
CCP2R-3-30CF
CCP2R-2-60CF
CCP2R-3-60CF
Left front rotary
CCP2RL-2-30CF
CCP2RL-3-30CF
CCP2RL-2-60CF
CCP2RL-3-60CF
Right side rotary
CCP2S-2-30CF
CCP2S-3-30CF
CCP2S-2-60CF
CCP2S-3-60CF
2
3
2
3
30
60
2
3
2
3
30
60
And
Rotary handles
Description
Rating
CCP2-H4X-B1
Selector handle — black/grey
Selector handle — red/yellow
Pistol handle — black/grey
Pistol handle — red/yellow
CCP2-H4X-R1
CCP2-H4X-B2
CCP2-H4X-R2
Type 1, 4X, 12
And
Shafts (8 mm)
CCP2-SH1-290
CCP2-SH1-490
Length
290 mm
490 mm
NFPA 79 compliant
handle
Color
CCP2-NFPA-1
Red
And
Multi-wire lug kits
Description
CCP2-MW1-3
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
11-24
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
And
Terminal shrouds
Description
CCP2-TS1-3
Pack of 3
Auxiliary contacts
Description — use with CCP2RL-(poles)-30/60CF switches
CCP2-AUX
NO/NC, 5 A / 240 V
Description — use with CCP2R-(poles)-30/60CF and CCP2S-(poles)-30/60CF
switches
PLC fuse monitor
CCP2-PLC-IND
Signal output 24 Vdc / 10 mA
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-25
Eaton.com/bussmannseries
11 — Disconnect switches
Ordering a complete switch installation
30 and 60 A CCP2 counterclockwise switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Left side rotary
CCP2SL-2-30CF
CCP2SL-3-30CF
CCP2SL-2-60CF
CCP2SL-3-60CF
2
3
2
3
30
60
And
Rotary handles
Description
Rating
CCP2-H4X-B1L
Selector handle — black/grey
Selector handle — red/yellow
Pistol handle — black/grey
Pistol handle — red/yellow
CCP2-H4X-R1L
CCP2-H4X-B2L
CCP2-H4X-R2L
Type 1, 4X, 12
And
Shafts (8 mm)
CCP2-SH1-290
CCP2-SH1-490
Length
290 mm
490 mm
NFPA 79 compliant
handle
Color
CCP2-NFPA-1
Red
And
Multi-wire lug kits
Description
CCP2-MW1-3
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
And
Terminal shrouds
CCP2-TS1-3
Description
Pack of 3
Auxiliary contacts
Description —mounts on right side
CCP2-AUX
NO/NC, 5 A / 240 V
11-26
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Ordering a complete switch installation
100 A CCP2 switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Switch (used alone or with flange cable or flange rod handles)
CCP2-1-100CF
1
2
3
CCP2-2-100CF
CCP2-3-100CF
100
And
Flange handle rod
operator
Description — 3-pole switches only
Rating
1, 3R and 12
4X
CCP2-FLR1-21
CCP2-FLR1-21X
Red/black painted handle
Chrome handle
Or
Flange handle cable
operator
Description - 3-pole switches only, cannot be used with side or
front rotary mechanisms
Rating
Type 1, 3R, 12
Type 4X
CCP2-FLC1-36
CCP2-FLC1-36X
CCP2-FLC1-60
CCP2-FLC1-60X
CCP2-FLC1-120
CCP2-FLC1-120X
36” cable, red/black painted handle
36” cable, chrome handle
60” cable, red/black painted handle
60” cable, chrome handle
Type 1, 3R, 12
Type 4X
120” cable, red/black painted handle
120” cable, chrome handle
Type 1, 3R, 12
Type 4X
Multi-wire lug kits
Description
CCP2-MW1-6
6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
And
Terminal shrouds
Description
CCP2-TS1-6
Pack of 3
Description — mounts on right side, cannot be used with flange handle rod or
cable operator
Auxiliary contacts
CCP2-AUX-100
NO/NC, 5 A / 240 V
Description — mounts on left side, cannot be used with flange handle rod
operator
PLC fuse monitor
CCP2-PLC-100
Signal output 24 Vdc / 10 mA
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-27
Eaton.com/bussmannseries
11 — Disconnect switches
Ordering a complete switch installation
100 A CCP2 clockwise rotary switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Right front rotary
CCP2R-2-100CF
CCP2R-3-100CF
2
3
100
Left front rotary
CCP2RL-2-100CF
2
3
100
100
CCP2RL-3-100CF
Right side rotary
CCP2S-2-100CF
2
3
CCP2S-3-100CF
And
Rotary handles
Description
Rating
CCP2-H4X-B1
Selector handle — black/grey
Selector handle — red/yellow
Pistol handle — black/grey
Pistol handle — red/yellow
CCP2-H4X-R1
CCP2-H4X-B2
CCP2-H4X-R2
Type 1, 4X, 12
And
Shafts (8 mm)
CCP2-SH1-290
CCP2-SH1-490
Length
290 mm
490 mm
NFPA 79 compliant
handle
Color
CCP2-NFPA-1
Red
And
Multi-wire lug kits
Description
CCP2-MW1-6
6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
11-28
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
And
Terminal shrouds
Description
CCP2-TS1-6
Pack of 3
Auxiliary contacts
Description — cannot be used on right front or right side operated switches
CCP2-AUX-100
NO/NC, 5 A / 240 V
PLC fuse monitor
Description — Cannot be used on left front or left side operated switches
CCP2-PLC-100
Signal output 24 Vdc / 10 mA
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-29
Eaton.com/bussmannseries
11 — Disconnect switches
Ordering a complete switch installation
100 A CCP2 counterclockwise switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Left side rotary
CCP2SL-2-100CF
CCP2SL-3-100CF
2
3
100
And
Rotary handles
Description
Rating
CCP2-H4X-B1L
Selector handle — black/grey
Selector handle — red/yellow
Pistol handle — black/grey
Pistol handle — red/yellow
CCP2-H4X-R1L
CCP2-H4X-B2L
CCP2-H4X-R2L
Type 1, 4X, 12
And
Shafts (8 mm)
CCP2-SH1-290
CCP2-SH1-490
Length
290 mm
490 mm
NFPA 79 compliant
handle
Color
CCP2-NFPA-1
Red
And
Multi-wire lug kits
Description
CCP2-MW1-6
6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
And
Terminal shrouds
CCP2-TS1-6
Description
Pack of 3
Auxiliary contacts
CCP2-AUX-100
Description — mounts on right side
NO/NC, 5 A / 240 V
11-30
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Features
About the UL Class CF CUBEFuse
•ꢀ
Smallest installed footprint of any UL Class CC, J, or R fuse
solution
•ꢀ
Easy application using CUBEFuse holders (TCFH_N), UL 98
Compact Circuit Protector (CCP2) switches and Compact
Circuit Protector Base (CCP2B up to 100 A). See data sheet
9007 for details on the CUBEFuse holder, 10801 for details on
the CCP2-_CF switch and 1161 for the CCP2B.
•ꢀ
Holders and switches have an amp rating rejection feature
to help prevent overfusing; 30, 60 and 100 A switches and
holders will hold any CUBEFuse up to its rating, 200 and 400
A switches and 200, 225 and 400 A holders will hold any
CUBEFuse 110 A and above up to its rating
•ꢀ
•ꢀ
•ꢀ
UL Class CF with Class J time-delay electrical performance
Available in indicating and non-indicating versions
The Bussmann series Low-Peak CUBEFuse is a UL Class CF current-
limiting, dual-element, time-delay branch circuit fuse with Class J
electrical performance. Available in indicating and non-indicating
versions, this finger-safe fuse has a very compact, space-saving
size and is easily applied using the CUBEFuse holder (TCFH_N),
UL 98 Compact Circuit Protector switch (CCP2-_CF) or Compact
Circuit Protector Base (CCP2B up to 100 A) used in the Quik-Spec
Coordination Panelboard).
The indicating version features local easyID™ open fuse
technology for faster troubleshooting and reduced downtime
•ꢀ
•ꢀ
•ꢀ
•ꢀ
Faster response to damaging faults helps reduce destructive
thermal and magnetic forces
True dual-element fuse construction with a minimum 10
seconds time-delay at 500% of rating
Ratings
Long time-delay minimizes nuisance openings caused by
temporary overloads and transient surges
•ꢀ
Volts
•ꢀ 600 Vac
•ꢀ 300 Vdc
Up to 300 kA interrupting rating safely interrupts virtually any
fault
•ꢀ
•ꢀ
•ꢀ
Robust cycling and inrush current withstand
Low let-through currents under fault conditions
•ꢀ
Amps
•ꢀ 6-400 A (indicating)
Provides Type 2 “No Damage” protection for IEC motor starters
when properly sized
•ꢀ 1-400 A (non-indicating)
•ꢀ
Interrupting rating
•ꢀ
Easy selective coordination with any other Bussmann series
Low-Peak Class CC, J, L or RK1 fuse with simple 2:1 amp ratio
between upstream and downstream fuses
•ꢀ 300 kA RMS Sym. (Up to 100 A UL)
•ꢀ 200 kA RMS Sym. (110 to 400 A UL)
•ꢀ 200 kA RMS Sym. (Up to 100 A CSA)
•ꢀ 100 kA DC (Up to 400 A UL and up to 100 A CSA)
* Finger-safe status depends on final, installed application, and will require
using accessory shrouds for 110 to 400 A ratings.
CUBEFuse (cat. no. TCFH_N) holders
Agency information
The CUBEFuse is also used in holders that can be dovetail
together for the smallest footprint possible of any Class J fuse
solution (see data sheet no. 9007 for details).
•ꢀ
UL Listed Class CF fuse: Guide JDDZ, File E4273 (up to 400 A)
CSA® Certified fuse: Class 1422-02,
File 053787_C_000 (up to 100 A)
•ꢀ
Finger-safe DIN-Rail or
panel mount holders up to
100 A.
•ꢀ
CE
•ꢀ
RoHS compliant
•ꢀ
30 A holder accepts any
CUBEFuse up to 30 A.
Catalog numbers (amps)
Indicating CUBEFuse
•ꢀ
60 amp holder accepts any
CUBEFuse up to 60 A.
TCF6
TCF30
TCF35
TCF40
TCF45
TCF50
TCF60
TCF70
TCF80
TCF90
TCF100
TCF110
TCF125
TCF150
TCF175
TCF200
TCF225
TCF250
TCF300
TCF350
TCF400
•ꢀ
100 amp holder accepts any
CUBEFuse up to 100 A.
TCF10
TCF15
TCF17-1/2
TCF20
TCF25
Panel mount holders from
200 to 400 A.
•ꢀ
200 A holder accepts any
CUBEFuse from 110 to 200 A
Non-Indicating CUBEFuse
•ꢀ
225 A* holder accepts any
CUBEFuse from 110 to 225 A
TCF1RN
TCF3RN
TCF6RN
TCF10RN
TCF15RN
TCF20RN
TCF25RN
TCF30RN
TCF35RN
TCF40RN
TCF50RN
TCF60RN
TCF70RN
TCF80RN
TCF90RN
TCF100RN
TCF110RN
TCF125RN
TCF150RN
TCF175RN
TCF200RN
TCF225RN
TCF250RN
TCF300RN
TCF350RN
TCF400RN
•ꢀ
400 A holder accepts any
CUBEFuse from 110 to 400 A
Finger-safe installation
achievable for three ganged
holders and lug kits with
shroud
TCF17-1/2RN TCF45RN
* 200 A and 225 A holders share the same overall dimensions, but the 200 A
holder will reject a 225 A fuse.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-31
Eaton.com/bussmannseries
11 — Disconnect switches
Ordering a complete switch installation
200 A CCP2 switches
For a complete installation, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
CCP2-1-200CF
1
CCP2-2-200CF
CCP2-3-200CF
200
2
3
And
Lug kits
Description
CCP2-L2-1
Stainless steel lug, 75° Cu only, 350 kcmil-4, 1 per pack
Aluminum lug, 75°C Cu/Al, 350 kcmil-4, 1 per pack
CCP2-L2-1A
CCP2-MW2-3
CCP2-MW2-6
3-port multi-wire lug, 75°C Cu/Al, 2-14, 3 per pack, includes terminal shroud
6-port multi-wire lug, 75°C Cu/Al, 6-14, 3 per pack, includes terminal shroud
And
Rotary
mechanisms
Description
CCP2-SM
Side rotary mechanism - mounts on left or right side of 1-, 2- and 3-pole switches
Front rotary mechanism - mounts only on 3-pole switches, requires clockwise
rotating handle
CCP2-RM2
And
Rotation - must match
Rotary handles
CCP2-H4X-B3
CCP2-H4X-R3
CCP2-H4X-B4
CCP2-H4X-R4
CCP2-H4X-B3L
CCP2-H4X-R3L
CCP2-H4X-B4L
CCP2-H4X-R4L
Description
switch rotation
Rating
Short pistol handle — black/grey
Short pistol handle — red/yellow
Long pistol handle — black/grey
Long pistol handle — red/yellow
Short pistol handle — black/grey
Short pistol handle — red/yellow
Long pistol handle — black/grey
Long pistol handle — red/yellow
And
Clockwise
For use with front rotary
mechanism or side rotary
mechanism CCP2-SM on
the switch’s right side
Type 1, 4X, 12
Counterclockwise
Use only if installing side
rotary mechanism CCP2-
SM on the switch’s left
side
Shafts (12 mm)
CCP2-SH2-225
CCP2-SH2-425
Length
225 mm
425 mm
NFPA 79
compliant handle
Color
CCP2-NFPA-2
Red
11-32
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Or
Description — 3-pole switches
Flange handle rod only, cannot be used with side or
operator
front rotary mechanisms
Red/black, painted handle
Chrome handle
Rating
Type 1, 3R and 12
Type 4X
CCP2-FLR2-21
CCP2-FLR2-21X
Or
Description - 3-pole switches only,
cannot be used with side or front
rotary mechanisms
Flange handle
cable operator
Rating
Type 1, 3R and 12
Type 4X
CCP2-FLC2-36
CCP2-FLC2-36X
CCP2-FLC2-60
CCP2-FLC2-60X
CCP2-FLC2-120
CCP2-FLC2-120X
36“ cable, red/black painted handle
36“ cable, chrome handle
60“ cable, red/black painted handle
60“ cable, chrome handle
120“ cable, red/black painted handle
120“ cable, chrome handle
And
Type 1, 3R and 12
Type 4X
Type 1, 3R and 12
Type 4X
Terminal shrouds
CCP2-TS2-3
Description
3-pole terminal shroud with phase shields, 1 per pack
Phase barriers
Description
CCP2-PB2
Phase barriers, 2 per pack
And
Control wire
terminals
Description
1/4” quick-connect control wire terminals - mounts on installed lug (cannot be used
with lug CCP2-L2-1), 12 per pack
CCP2-CWK2
Auxiliary contacts Description
CCP2-AUX-S
NO/NC, 5 A, 240 V - Can be mounted on right or left side
Handle extension
CCP2-HEX
Description
Handle extension to facilitate operating 1-, 2 and 3-pole switches. Cannot be used
when side or front rotary mechanisms or flange handle rod or cable operators are
installed.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-33
Eaton.com/bussmannseries
11 — Disconnect switches
Ordering a complete switch installation
400 A CCP2 switches
For a complete installation, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
CCP2-1-400CF
1
CCP2-2-400CF
CCP2-3-400CF
400
2
3
And
Lug kits
Description
CCP2-L4-1
Stainless steel lug, 75° Cu only, 500 kcmil-3, 1 per pack
Aluminum lug, 75° Cu only, 500 kcmil-3, 1 per pack
CCP2-L4-1A
CCP2-L4B-3
CCP2-L4B-3A
CCP2-MW6-6
CCP2-L6-3
Stainless steel lug, 75° Cu only, 750-500 kcmil, 3 per pack, includes terminal shroud
Aluminum lug, 75°C Cu/Al, 750-500 kcmil, 3 per pack, includes terminal shroud
6-port multi-wire lug, 75°C Cu/Al, 1/0-14, 3 per pack, includes terminal shroud
2-port stainless steel lug, 75° Cu only, 500 kcmil-2, 3 per pack, includes terminal shroud
2-port aluminum lug kit, 75° Cu/Al only, 500 kcmil-2, 3 per pack, includes terminal shroud
And
CCP2-L6-3A
Rotary
mechanisms
Description
CCP2-SM
Side rotary mechanism - mounts on left or right side of 1-, 2- and 3-pole switches
Front rotary mechanism - mounts only on 3-pole switches, requires clockwise
rotating handle
CCP2-RM4
And
Rotation - must match
Rotary handles
CCP2-H4X-B3
CCP2-H4X-R3
CCP2-H4X-B4
CCP2-H4X-R4
CCP2-H4X-B3L
CCP2-H4X-R3L
CCP2-H4X-B4L
CCP2-H4X-R4L
Description
switch rotation
Rating
Short pistol handle — black/grey
Short pistol handle — red/yellow
Long pistol handle — black/grey
Long pistol handle — red/yellow
Short pistol handle — black/grey
Short pistol handle — red/yellow
Long pistol handle — black/grey
Long pistol handle — red/yellow
And
Clockwise
For use with front rotary
mechanism or side rotary
mechanism CCP2-SM on
the switch’s right side
Type 1, 4X, 12
Counterclockwise
Use only if installing side
rotary mechanism CCP2-
SM on the switch’s left
side
Shafts (12 mm)
CCP2-SH2-225
CCP2-SH2-425
Length
225 mm
425 mm
NFPA 79
compliant handle
Color
CCP2-NFPA-2
Red
11-34
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Or
Flange handle rod Description - 3-pole switches only, cannot be used with side
operator
or front rotary mechanisms
Red/black, painted handle
Chrome handle
Rating
Type 1, 3R, 12
Type 4X
CCP2-FLR2-21
CCP2-FLR2-21X
Or
Flange handle
cable operator
Description - 3-pole switches only, cannot be used with side
or front rotary mechanisms
Rating
Type 1, 3R, 12
Type 4X
CCP2-FLC2-36
CCP2-FLC2-36x
CCP2-FLC2-60
CCP2-FLC2-60x
CCP2-FLC2-120
CCP2-FLC2-120x
36“ cable, red/black painted handle
36“ cable, chrome handle
60“ cable, red/black painted handle
60“ cable, chrome handle
120“ cable, red/black painted handle
120“ cable, chrome handle
And
Type 1, 3R, 12
Type 4X
Type 1, 3R, 12
Type 4X
Terminal shrouds
CCP2-TS6-3
Description
3-pole terminal shroud with phase shields, 1 per pack
Description
Phase barriers
CCP2-PB6
Phase barriers, 2 per pack
And
Auxiliary contacts Description
CCP2-AUX-S
NO/NC, 5 A, 240 V - Can be mounted on right or left side
Handle extension
Description
Handle extension to facilitate operating 1-, 2 and 3-pole switches. Cannot be used
when side or front rotary mechanisms, or flange handle rod and cable mechanisms
are installed.
CCP2-HEX
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-35
Eaton.com/bussmannseries
11 — Disconnect switches
CUBEFuse Compact Circuit Protector Base
Agency information
2011/65/EU
•ꢀ
UL 98 Listed, Guide WHTY, File E302370
•ꢀ
cULus to Canadian Standard 22.2 No. 4, Guide WHTY7,
File E302370
•ꢀ
RoHS compliant
•ꢀ
CE
Lineside bolt-on bus connector and torque
•ꢀ
Bolt-mounted design into Quik-Spec Coordination Panelboard bus
•ꢀ
#10-32 UNC hex flange Phillips screw; 2.8 N•m (25 lb-In)
Loadside box lug terminal conductor data
•ꢀ
See conductor table for details
1-Pole
2-Pole
3-pole
CCP2B-3-_CF
Loadside fork terminal
CCP2B-1-_CF
CCP2B-2-_CF
•ꢀ
Max. 30 A suitable for use with #8-32 UNC screw
Description
Lockout/tagout
The revolutionary Bussmann series Compact Circuit Protector
Base (CCP2B) with CUBEFus™ is a UL 98 horsepower rated fused
branch circuit disconnect. Primarily used in the Bussmann series
Quik-Spec™ Coordination Panelboard, the CCP2B with CUBEFuse
simplifies selective coordination for code complaince along with a
lockout/tagout feature for isolating individual branch circuit loads to
promote safe work practices.
•ꢀ
1/4” lock
Local open fuse indication
•ꢀ
Light illumination requires closed circuit and minimum 90 volts
Carton quantity and shipping weight
Features
Item
Poles
lbs (kg)
1.7 (0.77)
2.6 (1.18)
•ꢀ
Uses finger-safe, current-limiting Class CF CUBEFuse with Class
up to 60 amp switches
70 to 100 amp switches
6
6
J performance available, time-delay or fast-acting versions from 1
to 100 amps
•ꢀ
Patented amp rating rejection feature helps prevent overfusing
Environmental data
•ꢀ
High 200 kA short-circuit current rating
•ꢀ
Storage and operating temperature -20°C to 75°C**
•ꢀ
Disconnect rated to provide a means for load isolation
**For fuse performance under or above 25°C, consult fuse performance derating
charts.
•ꢀ
2- and 3-pole versions full voltage rated at 600 Vac
•ꢀ
Up to 125 Vdc ratings
Available Bussmann series fuses
•ꢀ
UL 98 Listed for branch circuit disconnect
UL fuse
class
Data sheet
no.
•ꢀ
1-, 2- and 3-pole versions are horsepower rated
Type/description
Volts
•ꢀ
Listed to UL and cULus
Indicating time-delay, Low-Peak
CUBEFuse (6-100 A)
•ꢀ
Open fuse indication lamp per pole speeds troubleshooting
600 Vac/
300 Vdc
9000
2147
Non-indicating time-delay,
Low-Peak CUBEFuse (1-100 A)
•ꢀ
Additional open fuse indication can be provided by using the time-
delay indicating CUBEFuse in ratings from 6 to 100 A
CF
Non-indicating fast-acting
CUBEFuse (1-100 A)
•ꢀ
Built-in switch/fuse interlock prevents removing or installing a fuse
while energized
600 Vac/dc
•ꢀ
Permanent lockout/tagout and lock-on provision usign a 1/4” lock
Lineside bolt-on bus connector
Specifications:
Switch amp ratings and rejection breaks
Switch ON and OFF symbols
Lockout/tagout provision
•ꢀ
15, 20, 30, 40, 50, 60, 70, 90 and 100 A
Poles
•ꢀ
1-, 2- and 3-poles
Switch handle
Volts
•ꢀ
600 Vac (or less)
Local open fuse indication light
•ꢀ
125 Vdc*
CUBEFuse base
* Switch amp rating and installed fuse amp rating dependent, see catalog number
table for details.
Loadside box lug and fork terminals
Data sheet no: 1161
11-36
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Catalog numbers and ratings
Box lug conductor data
AWG
Accepts
Voltage CUBEFuse
ratings amp range SCCR (Vac)†††
Torque
Quantity N•m (lb-in)
Catalog
numbers
Hp ratings
Wire type
range
Class
Poles
15 to 60 A switches
347 Vac,
4-6
8-18
3.95 (35)
2.26 (20)
3.39 (30)
Stranded, Class B
to K
Stranded, Class B/C
Stranded, Class K
CCP2B-1-15CF
CCP2B-2-15CF
1
0.5 Hp @ 120 V
Single
Dual
125 Vdc
600 Vac,
125 Vdc
2
3
1.5 Hp @ 240 V
1 to 15
1 to 20
1 to 30
1 to 40
1 to 50
1 to 60
1 to 70
1 to 90
1 to 100
6-8
3 Hp @ 240 V
5 Hp @ 480 V
7.5 Hp @ 600 V
2.26 (20)
Stranded, Class B
CCP2B-3-15CF
600 Vac
10-18
to K
Solid
75°C Cu
10-18
Single/dual
Single
2.26 (20)
3.39 (30)
347 Vac,
125 Vdc
600 Vac,
125 Vdc
CCP2B-1-20CF
CCP2B-2-20CF
1
2
0.75 Hp @ 120 V
2 Hp @ 240 V
4-18
6-18
4-18
6-18
Stranded, UL ferrule,
Class B/C
Twin†
Single
Stranded, UL
ferrule, Class K
2.82 (25)
3 Hp @ 240 V
7.5 Hp @ 480 V
10 Hp @ 600 V
Twin†
CCP2B-3-20CF
3
600 Vac
70 to 100 A switches
12-18
10
8
4-6
1-3
2.26 (20)
2.82 (25)
4.52 (40
5.08 (45)
6.21 (55)
347 Vac,
125 Vdc
600 Vac,
125 Vdc
CCP2B-1-30CF
CCP2B-2-30CF
1
2
1.5 Hp @ 120 V
3 Hp @ 240 V
Stranded, Class B
to K
Single
5 Hp @ 240 V
15 Hp @ 480 V
10 Hp @ 600 V
CCP2B-3-30CF
3
600 Vac
Stranded, Class B
to K
3-12
Dual
Single
Twin†
3.95 (35)
347 Vac,
125 Vdc
600 Vac,
125 Vdc
CCP2B-1-40CF
CCP2B-2-40CF
1
2
2.0 Hp @ 120 V
3 Hp @ 240 V
12-18
10
2.26 (20)
3.95 (35)
4.52 (40)
2.26 (20)
2.82 (25)
2.26 (20)
2.26 (20)
2.26 (20)
3.39 (30)
5.08 (45)
2.26 (20)
3.39 (30)
2.26 (20)
Stranded, UL
ferrule, Class B/C
1-8
10-18
75°C Cu
7.5 Hp @ 240 V
20 Hp @ 480 V
10 Hp @ 600 V
CCP2B-3-40CF
3
600 Vac
6-8
10-18
10-18
8-18
1-6
Single
Dual
347 Vac,
125 Vdc*
600 Vac,
125 Vdc*
Solid
CCP2B-1-50CF
CCP2B-2-50CF
1
2
3.0 Hp @ 120 V
5 Hp @ 240 V
200 kA
AC
Single
Dual
Class K
100 kA
DC
7.5 Hp @ 240 V
20 Hp @ 480 V
10 Hp @ 600 V
3-10
8-18
1-6
CCP2B-3-50CF
3
600 Vac
Single
Class K, UL ferrule
347 Vac,
125 Vdc*
600 Vac,
125 Vdc*
CCP2B-1-60CF
CCP2B-2-60CF
1
2
3.0 Hp @ 120 V
7.5 Hp @ 240 V
6-18
Twin
† Two stranded conductors placed in one UL Listed twin ferrule.
Dimensions — in (mm)
7.5 Hp @ 240 V
20 Hp @ 480 V
10 Hp @ 600 V
CCP2B-3-60CF
3
600 Vac
2.7
3.0
0.5
1.0
(76)
(69)
(13)
2.0
(25)
(51)
347 Vac,
125 Vdc
600 Vac,
125 Vdc
CCP2B-1-70CF
CCP2B-2-70CF
1
2
3.0 Hp @ 120 V
7.5 Hp @ 240 V
15 Hp @ 240 V
30 Hp @ 480 V
40 Hp @ 600 V
CCP2B-3-70CF
3
600 Vac
3.9
(99)
15-60 A
347 Vac,
CCP2B-1-90CF
CCP2B-2-90CF
1
2
5.0 Hp @ 120 V
10 Hp @ 240 V
125 Vdc**
600 Vac,
125 Vdc**
20 Hp @ 240 V
50 Hp @ 480 V
40 Hp @ 600 V
CCP2B-3-90CF
3
600 Vac
2.9
3.0
(73)
Ø 0.2
(76)
1.0
0.03
(0.8)
(Ø 5.1)
2.0
2.7
(25)
(51)
(70)
347 Vac,
CCP2B-1-100CF
CCP2B-2-100CF
1
2
5.0 Hp @ 120 V
10 Hp @ 240 V
125 Vdc**
0.54
(14)
600 Vac,
125 Vdc**
20 Hp @ 240 V
50 Hp @ 480 V
40 Hp @ 600 V
CCP2B-3-100CF
3
600 Vac
5.3
70-100 A
(133)
†
1 and 3 A indicating CUBEFuse not available. Correct fit with CCP2B discon-
nect requires indicating CUBEFuse with date code R38 or later.
Not for use with motors.
††
††† Indicating or non-indicating time-delay CUBEFuse only.
*
125 Vdc for installed fuse amp ratings up to 40 A. 24 Vdc for installed fuse
amp ratings from 45 to 60 A.
125 Vdc for installed fuse amp ratings up to 80 A, 24 Vdc for installed fuse
amp ratings from 90 to 100 A.
**
3.4
(86)
For details on the CCP2B and its use in the Quik-Spec Coordination
Panelboard, see data sheet no. 1160.
Data sheet no: 1161
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-37
Eaton.com/bussmannseries
11 — Disconnect switches
Compact Circuit Protector (cat. no. CCP2)
For use with Class CC, Supplemental and IEC 10x38 mm fuses
Class CC and midget CCP contents
Section page
Description and specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . .39-40
Catalog numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Conductor information and available fuses . . . . . . . . . . . . . . . . . . . . . 42
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Accessories
Multi-wire lug kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Selector and pistol handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
NFPA 79 compliant handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Auxiliary contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
PLC fuse monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46-47
How to order tables
Clockwise rotary operated switches . . . . . . . . . . . . . . . . . . . . . . . .48-49
Switches only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Counterclockwise rotary operates switches . . . . . . . . . . . . . . . . . . . . 51
CCP2 switch
CCP2 right front rotary switch
CCP2 left front rotary switch
CCP2 right side rotary switch
CCP2 left side rotary switch
11-38
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL Supplemental and IEC 10x38 mm fuse versions
•ꢀ
Catalog symbols
•ꢀ UL 508 Listed, Guide NRNT, File E320230
•ꢀ cULus Certified 22.2 No. 14-05
•ꢀ IEC 60947-3 AC-23A
Symbol
Fuse type
Class CC
UL sup./IEC 10x38
Class CC Vdc
UL sup./IEC 10x38 Vdc
Class CC
Description
CCP2-(poles)-30CC
CCP2-(poles)-30M
CCP2-1-DCC
CCP2-1-DCM
CCP2R-(pole)-30CC
CCP2R-(pole)-30M
CCP2RL-(pole)-30CC Class CC
CCP2RL-(pole)-30M UL sup./IEC 10x38
CCP2S-(pole)-30CC
CCP2S-(pole)-30M
CCP2SL-(pole)-30CC Class CC
Switch only
•ꢀ
•ꢀ
DC voltage UL Class CC version (CCP2-1-DCC)
1-pole switch only
•ꢀ UL 508 Listed, cULus 22.2, No. 1405
DC IEC 10x38 version (CCP2-1-DCM)
Right front rotary switch
Left front rotary switch
Right side rotary switch
Left side rotary switch
UL sup./IEC 10x38
•ꢀ IEC 60947-3, DC-23A
•ꢀ
•ꢀ
RoHS compliant
CE
Class CC
UL sup./IEC 10x38
Conductors/terminals
•ꢀ
75°C Cu/Al, see conductor tables for size, type and torque
information
CCP2SL-(pole)-30M UL sup./IEC 10x38
Description
•ꢀ
Box lug, single/dual conductor
The revolutionary next generation Bussmann™ series Compact
Circuit Protector (cat. no. CCP2) fused disconnect switch is 3/5 the
footprint of a traditional fusible switch and provides up to a high 200
kA Short-Circuit Current Rating (SCCR) to help improve panel and
assembly SCCR.
•ꢀ
Fork terminal suitable for line, load or accessory connection
•ꢀ
Multi-wire lug kit — see accessories for details
Storage and operating temperature
•ꢀ
- 20°C to 75°C (-4°F to 167°F)*
The 35 mm DIN-Rail mount CCP is available in a variety of
configurations to meet many application needs including rotary
operation.
* For fuse performance under or above 25°C, consult fuse performance derating
charts in the Bussmann Division publication no. 3002, titled Selecting Protective
Devices (SPD)
Application flexibility is extended with an optional multi-wire lug kit,
with finger-safe shrouds, that provides three additional wire ports on
each pole for power distribution applications.
Lockout/tagout provisions
•ꢀ
Switch only — 4 mm lock or Brady pin-out device part number
90850
Other accessories include a PLC interface device for open fuse
monitoring and NO/NC auxiliary contacts that easily integrate into
many monitoring systems.
•ꢀ
Switch with rotary operating mechanism — 1/4” lock
Front and side rotary operated versions are easily applied for
through-the-door or through the left or right side operation to
enhance safety.
Minimum enclosure size
•ꢀ
10” x 8” x 6” (254 x 203 x 152 mm)
Mounting
Ratings
•ꢀ
35 mm DIN-Rail
•ꢀ
Volts
600 Vac (UL® Class CC)
•ꢀ
Local open fuse indication minimum voltage**
•ꢀ
240 Vac (UL Supplemental)
•ꢀ
90 Vac for AC switches
•ꢀ
400 Vac (IEC 10x38 mm)
•ꢀ
12 Vdc for DC switches
•ꢀ
80 Vdc (DC Class CC, DC UL Supplemental/IEC)
** Open fuse indication requires an open fuse to be in the CCP2 and the switch
in the ON position.
•ꢀ
Amps
•ꢀ
30 A (UL)
Accessories
•ꢀ
32 A (IEC)
•ꢀ
Multi-wire lug kit with terminal shrouds
•ꢀ
SCCR
•ꢀ
Selector and pistol handles for use with rotary operated switches
•ꢀ
200 kA (UL Class CC)
•ꢀ
8 mm shafts for use with selector and pistol handles
•ꢀ
10 kA (UL Supplemental)
•ꢀ
Auxiliary contacts
•ꢀ
120 kA (IEC 10x38 mm max)
•ꢀ
PLC fuse monitor
•ꢀ
20 kA (DC Class CC/UL)
•ꢀ
10 kA (DC UL Supplemental/IEC)
Poles
•ꢀ
1-, 2- and 3-poles catalog number dependent
Agency information
•ꢀ
UL Class CC fuse versions
•ꢀ UL 98 Listed, Guide WHTY, File E302370
•ꢀ cULus to Canadian Standard 22.2 No. 4-04, UL Guide WHTY7,
File 302370
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-39
Eaton.com/bussmannseries
11 — Disconnect switches
Features
•ꢀ
Extremely compact (18 mm wide per pole ) design
•ꢀ
High SCCR up to 200 kA (UL Class CC) and 120 kA (IEC)
•ꢀ
Disconnect rated for load isolation
•ꢀ
Full voltage rated up to 600 Vac or 80 Vdc
•ꢀ
UL 98 Listed Class CC version is horsepower rated and suitable
for branch circuit protection and disconnect
•ꢀ
IEC 10x38 version complies with IEC 60947-3 and suitable for
branch circuit protection and disconnect
•ꢀ
Suitable for global installations, the switches comply with UL,
cULus and IEC standards accepting UL Class CC, Supplemental
or IEC aM and gG/gL fuses
•ꢀ
Open fuse indication
•ꢀ Standard local open fuse indicating light for each pole
•ꢀ Optional PLC fuse monitor can be utilized to signal a PLC and
open a contactor to de-energize all phases, if required
IP20 finger-safe with 10 AWG (6 mm2) or larger wire (box lug
terminals only)
•ꢀ
•ꢀ
Built-in switch interlock prohibits removing the fuse under load
•ꢀ
Padlockable handle for lockout/tagout
•ꢀ 4 mm lock for switch only
•ꢀ 1/4” lock for rotary operated switches
•ꢀ
Rotary operated versions provide for through-the-door and
through-the-side operation flexibility and enhanced safety with:
•ꢀ Right front switch operation
•ꢀ Left front switch operation
•ꢀ Right side switch operation
•ꢀ Left side switch operation
Right front rotary operated CCP2 switch with PLC fuse monitor.
•ꢀ
Optional selector and pistol handles available for use with rotary
operated versions
Rotary operating switch versions
•ꢀ
Multi-wire lug kit with terminal shrouds allows for power
distribution to multiple loads. Each lug has three ports rated for
single and dual wires (see lug kit in accessories for conductor and
torque details).
Switch handle
(ganged on 2- and
Open fuse
indicating light
3-pole versions)
Left front rotary switch
Right front rotary switch
Fuse access door
Clockwise operating handles
Clockwise operating handles
Fork terminal
Box lug terminal
Lockout/tagout
provision
Right side rotary switch
Left side rotary switch
Clockwise operating handles
Counterclockwise operating
handles
11-40
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Catalog numbers
Max horsepower rating (Vac)
Wire type/
size*
Catalog no.
Poles Description
Amps
Volts
SCCR
120
240
480
600
Class CC
CCP2-1-30CC
CCP2-2-30CC
CCP2-3-30CC
CCP2R-2-30CC
CCP2R-3-30CC
CCP2RL-2-30CC
CCP2RL-3-30CC
CCP2S-2-30CC
CCP2S-3-30CC
CCP2SL-2-30CC
CCP2SL-3-30CC
1
347 Vac
600 Vac
1/2
—
—
2
3
2
3
2
3
2
3
2
3
—
—
5
—
—
7. 5
2
3
2
3
2
3
2
3
2
3
Switch only
3/4
—
Switch with right
front rotary operation
600 Vac
600 Vac
600 Vac
600 Vac
75°C Cu/Al
18-4 AWG
3/4
—
5
—
5
7. 5
—
30 A
200 kA
Switch with left front
rotary operation
Fork terminal††
3/4
—
7. 5
—
—
5
Switch with right side
rotary operation
3/4
—
7. 5
—
—
5
Switch with left side
rotary operation
3/4
7. 5
UL Supplemental and IEC 10x38 mm
CCP2-1-30M
1
2
3
2
3
2
3
2
3
2
3
CCP2-2-30M
Switch only
CCP2-3-30M
CCP2R-2-30M
CCP2R-3-30M
CCP2RL-2-30M
CCP2RL-3-30M
CCP2S-2-30M
CCP2S-3-30M
CCP2SL-2-30M
CCP2SL-3-30M
Switch with right
front rotary operation
75°C Cu/Al
18-4 AWG
UL 240 Vac†
IEC 400 Vac†
UL 30 A
IEC 32 A**
UL 10 kA†
IEC 120 kA†
—
—
—
—
Switch with left front
rotary operation
Fork terminal††
Switch with right side
rotary operation
Switch with left side
rotary operation
Single-pole DC switches
CCP2-1-DCC
1
UL Class CC
30 A
30 A
80 Vdc†
80 Vdc†
20 kA†
10 kA†
—
—
—
—
—
—
—
—
75°C Cu/Al
18-4 AWG
UL supplemental
CCP2-1-DCM
1
Fork terminal††
IEC 10x38
32 A**
* See box lug terminal conductor data table for details.
**32 A Class aM, 25 A Class gG.
† SCCR may be lower, refer to installed fuse data sheet for interrupting rating at applied voltage.
††Fork terminal with a 4.3 mm gap for a #8-32 stud, 30 A max, insulated flange, wire size 12-10 AWG.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-41
Eaton.com/bussmannseries
11 — Disconnect switches
Box lug terminal conductor data
Left front and right front rotary switches
78
3.1
AWG
Torque
53
99
2.1
35
1.4
Type range Class
Quantity N•m (lb-in)
Single
Dual
3.9
49
1.9
18
0.7
4-18 Stranded, Class B to K
6-8
6-8
10-18 Stranded, Class B to K
10-18 Solid
2.26 (20)
3.39 (30)
Stranded, Class B/C
Stranded, Class K
Dual
2.26 (20)
Single/dual
Single
Twin†
Cu
93
3.7
4-18
Stranded, UL ferrule, Class B/C
6-18
3.39 (30)
2.82 (25)
4-18
Single
Twin†
Single
Stranded, UL ferrule, Class K
6-18
4-8
2.26 (20)
2.82 (25)
2.26 (20)
80
3.1
Al
6
8
Stranded
Dual
78
99
[3.9]
[3.1]
53
[2.1]
35
[1.4]
49
[1.9]
18
[0.7]
† Two stranded conductors placed in one UL Listed twin ferrule.
Available Bussmann series fuses
Data
sheet
no.
Fuse
class
93
[3.7]
Type/description
LP-CC time-delay
FNQ-R time-delay
KTK-R fast-acting
FNM time-delay
FNQ time-delay
KTK fast-acting
BAF fast-acting
KLM fast-acting
Volts
93
[3.7]
600 Vac/300 Vdc*
600 Vac/300 Vdc
600 Vac
1023
1014
1015
2028
1012
1011
CC
250 Vac
500 Vac
80
[3.1]
M
600 Vac
250 Vac
2011
2020
720115
600 Vac/dc
500 V (400 V@32 A)
Left side and right side rotary switches
gG/gL C10G
aM C10M
78
3.1
53
2.1
500 V (400 V@20@25 A) 720115
35
1.4
18
0.7
49
1.9
* 1/2 to 2-1/2 and 20 to 30 A are 300 Vdc, 2-8/10 to 15 A are 150 Vdc.
93
3.7
Dimensions – mm (in)
Switch
53
2.1
35
1.4
49
1.9
18
0.7
80
3.1
78
3.1
53
2.1
35
1.4
49
1.9
18
0.7
93
3.7
93
3.7
80
3.1
80
3.1
11-42
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Installed on CCP2-3-xx
Multi-wire lug kit
Catalog number
•ꢀ
CCP2-MW1-3
Description
The multi-wire lug kit permits expanding each box lug terminal
on the switch into a three-port terminal for power distribution
applications.
Each multi-wire lug kit comes with three (3) three-port lugs and
three terminal shrouds. Shrouds provide finger-safe protection when
properly installed.
Lugs may be mounted on either the loadside or lineside to meet
various application needs.
Ports on any one lug accept any conductor combination listed, e.g.,
one of the three ports may have dual 14 AWG wires and the other
two ports single 10 AWG wires.
Ratings
Multi-wire lugs mount in switch box lug terminals to provide three
additional wire ports per pole. Lugs can be mounted on the switch
lineside or loadside. Each multi-wire lug kit comes with three lugs
and three shrouds.
•ꢀ
Volts 600 V
•ꢀ
Amps 60 A max
•ꢀ
SCCR 200 kA
Agency information
Wire insulation strip lengths
•ꢀ
UL Recognized (lug only)
1/8” Allen
head screw
•ꢀ
RoHS compliant
Storage and operating temperature
1 = 11/16”
2 = 1-1/8”
3 = 1-9/16”
•ꢀ
- 20°C to 75°C (-4°F to 167°F)
Multi-wire lug conductor information
•ꢀ
75°C Cu/AL
•ꢀ
AWG size and quantity per port - see table below
Strip back wire insulation to the lengths as indicated in the
illustration above and the table below.
AWG
Type range
Torque
N•m (lb-in)
Class
Quantity
4-6
3.95 (35)
2.82 (25)
2.26 (20)
2.26 (20)
2.82 (25)
2.26 (20)
Lug port
Strip wire insulation back (inch)
Cu/Al
8
Stranded, Class B/C
Single
1
2
3
11/16
1-1/8
10-14
Stranded, Class B/C
Solid
Single/dual*
Single
10-14
1-9/16
Cu
8
UL ferrule, Class B to K Single/twin†
10-14
* Dual wire to be same size and type.
† Two stranded conductors placed in one UL Listed twin ferrule.
CCP2 box lug torque for multi-wire lug
•ꢀ
4.52 N•m (40 lb-in)
Terminal shroud accessory
Terminal shrouds are available without multi-wire terminals.
Catalog no.
Description
CCP2-TS1-3
Pack of three
Wiring versatility is provided by single/dual rated box lug terminals
on the switch, or by the three-port multi-wire lug kit that’s also
single/dual wire rated.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-43
Eaton.com/bussmannseries
11 — Disconnect switches
Selector and pistol handles
Selector handles
Catalog symbol
•ꢀ
CCP2-H4X-_
Description
Selector and pistol handles for use with any 2- and 3-pole CCP2
rotary operated switch. Both selector and pistol handles are available
in black/grey and red/yellow colors and clockwise/counterclockwise
operating modes. Applying clockwise and counterclockwise
operation depends upon the CCP2 rotary switch configuration.
Installation requires an 8 mm shaft (ordered separately).
Pistol handles
Each handle is rated NEMA 4X and capable of accepting up to three
(3) 1/4” diameter shank locks for lockout/tagout in the OFF position.
They can also be field configured for lock-on.
In application, only the clockwise operating handles in combination
with either the left front or right front rotary switches provide a door
interlock means to ensure the enclosure door remains shut during
lockout/tagout or lock-on. Both clockwise and counterclockwise
operating handles when mounted on the enclosure’s left or right side
do NOT provide a door interlock means.
Handle shafts
See the catalog number table below for applicable rotary switch,
handle and shaft combinations.
Agency information
•ꢀ
UL Listed, Guide DIHS, File E140305
•ꢀ
NEMA 4X rating
•ꢀ
RoHS compliant
•ꢀ
CE
Storage and operating temperature
•ꢀ
-20°C to 75°C (-4°F to 167°F)
NFPA 79 compliant handle
Catalog number
Packaging
•ꢀ
Each handle is packaged individually
•ꢀ
CCP2-NFPA-1
Description
Handle shafts
NFPA 79 compliant handle mounts on
the shaft of front rotary operated switch
installations and provide a lockout means
independent of the door position.
Catalog symbol
•ꢀ
CCP2-SH1-_
Description
Eight millimeter square shafts available in 290 and 490 millimeter
(11.5 and 19.3 inch) lengths. Shafts are indexed to ensure handle/
switch orientation for correct operation. Shafts are cut to length
when installed.
Packaging
•ꢀ
Each shaft is packaged separately
For these switch
catalog numbers
Order these handle catalog numbers
(description)
Description/operation
Order either shaft catalog number
CCP2R-(pole)-30CC
CCP2R-(pole)-30M
CCP2RL-(pole)-30CC
CCP2RL-(pole)-30M
CCP2S-(pole)-30CC
CCP2S-(pole)-30M
Right front rotary, clockwise
• CCP2-H4X-B1 (selector, black/grey)
• CCP2-H4X-R1(selector, red/yellow)
• CCP2-H4X-B2 (pistol, black/grey)
• CCP2-H4X-R2 (pistol, red/yellow)
Left front rotary, clockwise
Right side rotary, clockwise
• CCP2-SH1-290 (11.5”/290 mm)
• CCP2-SH1-490 (19.3”/490 mm)
• CCP2-H4X-B1L (selector, black/grey)
• CCP2-H4X-R1L (selector, red/yellow)
• CCP2-H4X-B2L (pistol, black/grey)
• CCP2-H4X-R2L (pistol, red/yellow)
CCP2SL-(pole)-30CC
Left side rotary, counterclockwise
CCP2SL-(pole)-30M
11-44
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Installed on a CCP2-3-xx
Auxiliary contacts
Note: CCP2-AUX CANNOT be mounted on the right front and right
side rotary operated versions.
Catalog number
•ꢀ
CCP2-AUX
Description
NO+NC contact output to indicate the
switching mechanism status on the
CCP2. A single unit can be mounted
on any 1-, 2- or 3-pole CCP2 switch
and the left front/left side rotary
operated switches.
Ratings
•ꢀ
Amps up to 5 A
•ꢀ
Volts up to 240 Vac
•ꢀ
NC/NO contacts are closed/open when the CCP2 switch is in the
“ON” position (closed)
Dimensions — in
Description
Max per CCP2*
Signal output
1.8
Auxiliary contacts NO+NC
for switch status
1 per CCP2
(1-, 2- or 3-pole)
5 A / 240 Vac
* The CCP2-AUX CANNOT be mounted on the right front and right side rotary
operated versions.
De-energize all circuits and follow all prevailing safety procedures before
installing or removing the CCP2-AUX.
2.6
Agency information
STRIP
•ꢀ
1.9
UL 98 Recognized, Guide WHTY2, File E155130
33 NO
41 NC
34 NO
42 NC
•ꢀ
cURus to Canadian Standard 22.2 No. 4-04
•ꢀ
IP20 finger-safe in installed state
•ꢀ
RoHS compliant
0.19
•ꢀ
3.7
CE
0.3
Wiring
75°C Cu, 20-16 AWG (0.5 to 1.5 mm2) wire
•ꢀ
•ꢀ
Torque 0.56 N•m (5 lb-in)
Packaging
•ꢀ
The CCP2-AUX is packaged individually
Installation technique
•ꢀ
Mounts on the CCP2’s right side ONLY and mechanically
interlocks with the CCP2 switch handle with provided hardware.
The CCP2-AUX CANNOT be mounted on the right front and right
side rotary operated versions.
Storage and operating temperature
•ꢀ
-20°C to 75°C (-4°F to 167°F)
CCP2-AUX auxiliary contacts mounted on a 3-pole CCP2 switch.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-45
Eaton.com/bussmannseries
11 — Disconnect switches
PLC fuse monitor
Wiring
•ꢀ
For power, signal and ground connections use shielded twisted
Catalog number
pair 22-24 AWG (0.34-0.25 mm2) 300 V rated wire
•ꢀ
CCP2-PLC-IND
Packaging
Description
•ꢀ
The CCP2-PLC-IND is packaged individually
A resettable three-phase
•ꢀ
Includes 0.110” (2.8 mm) quick connects for power, signal and
ground connections
fuse monitor that integrates
with the I/O card in a
Programmable Logic
Installation technique
Controller (PLC). A single
•ꢀ
Mounts on the left side ONLY of the CCP2 and mechanically
unit can be mounted on
interlocks with the CCP2 switch handle with hardware provided.
The CCP2-PLC-IND CANNOT be mounted on the left front/
left side rotary operated versions or if the multi-wire lug kit is
installed.
any 1-, 2- or 3-pole CCP2
switch and the right front/ right side rotary operated switches.
A single unit monitors up to three phases. When used on 1- and
2-pole switches unused conductor(s) are removed after installation.
The CCP2-PLC-IND CANNOT be mounted on the left front/left side
IP20 rating — yes
rotary operated versions or if the multi-wire lug kit is installed.
Storage and operating temperature
Ratings
•ꢀ
-20°C to 75°C (-4°F to 167°F)
•ꢀ
Signal output to PLC*
PLC programming
•ꢀ +24 Vdc, 10 mA max
•ꢀ
The CCP2-PLC-IND signal line is designed to provide a digital
•ꢀ
Output signals
input to a PLC I/O card. In this case, a Programmable Logic
Control program must be written to properly interpret the input
signal to the PLC. The PLC program should check for consecutive
high signals before taking action on a critical process.
•ꢀ Digital 0 Vdc (low), 24 Vdc max (high)
•ꢀ 0 Vdc Low – fuse is good
•ꢀ 24 Vdc High – fuse has opened
Installed on a CCP2-3-xx
* When the fuse opens, the output signal is sent high and will remain high until
the unit is reset.
Emissions and immunity testing
•ꢀ
IEC 60947-1: Voltage Switchgear and Control Gear
•ꢀ
IEC 61000-6-2: Electromagnetic Compatibility (EMC)
•ꢀ IEC 61000-4-2: Electrostatic Discharge Immunity - Test at level
3 (6 kV-Contact Discharge) and level 2 (4 kV-Air Discharge)
•ꢀ IEC 61000-4-3: Electromagnetic Compatibility - Radiated, Radio-
frequency, Electromagnetic Field Immunity test at level x
(20 V/m)
•ꢀ IEC 61000-4-4: Electromagnetic Compatibility - Testing and
Measurement Techniques at level 3 (± 2 kV - Power Port and
±1 kV - I/O Ports)
CCP2-PLC-IND mounted on a 3-pole switch and using the fork
terminals. When mounted on a 2- or 1-pole switch, remove unused
leads.
•ꢀ IEC 61000-4-5: Electromagnetic Compatibility - Surge Immunity
test at level 4 (±4 kV)
Note: The CCP2-PLC-IND CANNOT be mounted on the left front/left
side rotary operated versions or if the multi-wire lug kit is installed.
•ꢀ IEC 61000-4-6: Immunity to Conducted Disturbances at level 3 (10 V)
Max per
CCP2**
Signal output Min. circuit
to PLC volts
Description
Wired remote fuse
indication for PLC
applications
1 per CCP2
(1, 2- or 3-pole)
24 Vdc/ 10 mA 100 Vac
**The CCP2-PLC-IND CANNOT be mounted on the left front/left side rotary
operated versions or if the multi-wire lug kit is installed.
De-energize all circuits and follow all prescribed safety procedures before installing
or removing the CCP2-PLC-IND.
Agency information
•ꢀ
UL 98 Recognized, Guide WHTY2, File E155130
•ꢀ
cURus to Canadian, Standard 22.2 No. 4-04
Local indication
•ꢀ
Two distinct LEDs indicate unit power (green) and open fuse (red).
Open fuse LED is resettable upon fuse replacement and actuating
the reset switch.
CCP2-PLC-IND fuse monitor mounted on a right front rotary
operated switch.
11-46
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
CCP2-PLC-IND connections from a CCP2-3-xx to a remote
monitoring device
PLC wiring schematic
PLC power supply
PLC fuse monitor
Circuit monitoring leads from
CCP2-PLC-IND to CCP2
(100 – 600 Vac)
+24 Vdc
+24 Vdc
0 Vdc/Gnd
0 Vdc/Gnd
Signal
10 mA max.
Circuit monitoring
leads from PLC or
remote monitoring
device.
The PLC fuse monitor needs
to be powered by the same
+24 Vdc and ground
(0 Vdc/Gnd return)
terminals that feed the
PLC input card.
If it is not, it may
improperly signal.
If feeding multiple
+24 Vdc
PLC fuse monitors from
different power supplies,
there must be multiple
input cards being powered
by those same power
supplies as well.
0 Vdc/Gnd
PLC
input card
Connection from CCP2-PLC-IND to CCP2-3-xx
Lead from CCP2-PLC-IND
Power lead
Leads from CCP2-PLC-IND are connected to the fork terminals as
shown.
Note: When monitoring a 1- or 2-pole switch, remove unused leads.
Dimensions — in
1.8
Pin interlocks with
CCP2 switch handle
2.6
1.9
3.7
0.3
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-47
Eaton.com/bussmannseries
11 — Disconnect switches
Class CC and UL Supplemental (IEC 10x38) clockwise rotary switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Right front rotary
CCP2R-2-30CC
CCP2R-3-30CC
CCP2R-2-30M
2
3
2
30
CCP2R-3-30M
3
Left front rotary
CCP2RL-2-30CC
CCP2RL-3-30CC
CCP2RL-2-30M
CCP2RL-3-30M
Right side rotary
CCP2S-2-30CC
CCP2S-3-30CC
CCP2S-2-30M
2
3
2
3
30
30
2
3
2
3
CCP2S-3-30M
And
Rotary handles
Description
NEMA rating
CCP2-H4X-B1
Selector handle — black/grey
Selector handle — red/yellow
Pistol handle — black/grey
Pistol handle — red/yellow
CCP2-H4X-R1
CCP2-H4X-B2
CCP2-H4X-R2
4X
And
Shafts (8 mm)
CCP2-SH1-290
CCP2-SH1-490
Length
290 mm
490 mm
NFPA 79 compliant
handle
Color
CCP2-NFPA-1
Red
And
Lug kits
Description
CCP2-MW1-3
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
11-48
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
And
Terminal shrouds
Description
CCP2-TS1-3
Pack of 3
Auxiliary contacts
CCP2-AUX
Description — cannot be used on right front or right side operated switches
NO + NC, 5 A / 240 V
PLC fuse monitor
Description — Cannot be used on left front operated switches
CCP2-PLC-IND
Signal output 24 Vdc / 10 mA
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-49
Eaton.com/bussmannseries
11 — Disconnect switches
Class CC and UL Supplemental (IEC 10x38) Switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Switch
CCP2-1-30CC
CCP2-2-30CC
CCP2-3-30CC
CCP2-1-30M
CCP2-2-30M
CCP2-3-30M
1
2
3
1
2
3
30
And
Lug kits
Description
CCP2-MW1-3
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
And
Terminal shrouds
Description
CCP2-TS1-3
Pack of 3
Auxiliary contacts
CCP2-AUX
Description
NO + NC, 5 A / 240 V
Description
PLC fuse monitor
CCP2-PLC-IND
Signal output 24 Vdc / 10 mA
11-50
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Class CC and UL Supplemental (IEC 10x38) counterclockwise switches
For a complete assembly, select from the following required and optional components, and accessories.
Catalog no.
Switches
Amps
Poles
Left side rotary
CCP2SL-2-30CC
CCP2SL-3-30CC
CCP2SL-2-30M
CCP2SL-2-30M
2
3
2
2
30
And
Rotary handles
Description
NEMA rating
CCP2-H4X-B1L
Selector handle — black/grey
Selector handle — red/yellow
Pistol handle — black/grey
Pistol handle — red/yellow
CCP2-H4X-R1L
CCP2-H4X-B2L
CCP2-H4X-R2L
4X
And
Shafts (8 mm)
CCP2-SH1-290
CCP2-SH1-490
Length
290 mm
490 mm
And
Lug kits
Description
CCP2-MW1-3
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3
And
Terminal shrouds
CCP2-TS1-3
Description
Pack of 3
Auxiliary contacts
Description —mounts on right side
CCP2-AUX
NO + NC, 5 A / 240 V
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-51
Eaton.com/bussmannseries
11 — Disconnect switches
CCPLP UL 98 Listed low profile Compact Circuit
Protector
Poles
1-, 2- and 3-pole factory configured*
2011/65/EU
* 2- and 3-pole versions supplied as ganged switches with phase barriers.
The revolutionary Bussmann
series low profile Compact
Agency information
Circuit Protector (CCPLP) is a UL
98/508 Listed fused disconnect
switch. This front panel mount
switch is available in 1-, 2- and
3-pole versions, and has the
smallest footprint of any fused
disconnect switch. It features
an SCCR up to 200 kA to help
improve equipment SCCR.
•ꢀ
Class G fuse versions
•ꢀ UL 98 Listed, Guide WHTY, File E302370
•ꢀ IEC 60947-3 AC-23A
•ꢀ
Class CC fuse versions
•ꢀ UL 98 Listed, Guide WHTY, File E302370
•ꢀ cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7,
File E302370
Four fuse types
•ꢀ IEC 60947-3 AC-23A
The CCPLP is available for UL Class CC and G, UL supplemental
(13/32” x 1-1/2”) and IEC 10x38 mm fuses.
•ꢀ
UL supplemental and IEC 10x38mm fuse versions
Class CC and G versions are easily selectively coordinated with
the upstream Bussmann series CUBEFuse™ using published fuse
ampacity ratio tables.
•ꢀ UL 508 Listed, Guide NRNT, File E320230
•ꢀ cULus Listed to Canadian Standard 22.2 No. 14-05, Guide
NRNT7,
File E320230
Design/application flexibility
•ꢀ IEC 60947-3 AC-23A
The CCPLP is easily integrated into many panel designs and provides
a high SCCR alternative to low profile circuit breakers on the market.
•ꢀ
RoHS compliant
•ꢀ
CE
Ratings
Safety
•ꢀ
Volts
•ꢀ
Finger-safe IP20 from panel front
•ꢀ 600 Vac (Class CC up to 30 A, Class G 20 A)
•ꢀ 550 Vac (10x38mm IEC Class aM 0.16-16 A)
•ꢀ 500 Vac (10x38mm IEC Class gG 0.5-25 A)
•ꢀ 400 Vac (10x38mm IEC Class aM 20-32 A, gG 32 A)
•ꢀ 240 Vac (13/32” x 1-1/2” UL supplemental 30 A)
Mounting
•ꢀ
Front panel mounting with customer supplied M3 screws
Open fuse indication*
•ꢀ
Amps
•ꢀ
Local open fuse indication provided for each pole by an orange
neon lamp (minimum 90 V)
•ꢀ Up to 30 A (UL)
•ꢀ Up to 32 A (IEC)
* Open fuse indication requires an energized, closed circuit with an open fuse in
the CCPLP and the switch in the ON position.
•ꢀ
SCCR
Lockout/tagout provision
•ꢀ 200 kA (Class CC)
•ꢀ
•ꢀ 120 kA (10x38mm IEC Class gG and aM)
•ꢀ 100 kA (Class G)
Brady pin-out device, part number 90844
Circuit labeling provision
•ꢀ 10 kA (13/32” x 1-1/2” UL supplemental)
•ꢀ
Accepts up to two universal marker labels, catalog number
TM26CB
•ꢀ
Frequency 50/60 Hz
•ꢀ
Impulse voltage 8 kV
Carton quantity
Terminals and conductors 75°C/90°C Cu
•ꢀ
12 poles (1-pole: 12 units, 2-pole: 6 units, 3-pole: 4 units)
•ꢀ
Screw terminal, 10-32 phil-slot screw with external tooth lock
Minimum enclosure size
washer (use with properly rated/UL Listed ring or fork terminal)
•ꢀ
Pressure plate terminal, 10-32 phil-slot screw (single 22-6 AWG
solid or stranded)
•ꢀ
6” x 6” x 4” per UL 98 Listing
Ambient storage and operating temperature
•ꢀ
-20 to 90°C, 85% relative humidity, non-condensing
Data sheet no.10372
11-52
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Available CCPLP versions
Catalog no.
Horsepower (Vac)
SCCR
Screw terminal
UL Class G fuse
CCPLP-1-20G-S
CCPLP-2-20G-S
CCPLP-3-20G-S
UL Class CC fuses
CCPLP-1-30CC-S
CCPLP-2-30CC-S
CCPLP-3-30CC-S
Pressure plate terminal
Poles
Volts AC
Amps
(kA)
120
240
480
600
CCPLP-1-20G-P
CCPLP-2-20G-P
CCPLP-3-20G-P
1
2
3
—
—
—
—
—
—
—
—
—
—
—
—
600
20
100
CCPLP-1-30CC-P
CCPLP-2-30CC-P
CCPLP-3-30CC-P
1
2
3
0.5
—
—
—
2
3
—
—
4
—
—
7. 5
600
240
30
30
200
UL 13/32”x1-1/2” midget fuses
CCPLP-1-30M-S
CCPLP-1-30M-P
1
2
3
—
—
—
—
—
—
—
—
—
—
—
—
CCPLP-2-30M-S
CCPLP-2-30M-P
CCPLP-3-30M-P
10
CCPLP-3-30M-S
IEC 10x38 gG and aM fuses
gG fuses:
up to 25 A @ 500 V
32 A @ 400 V
CCPLP-1-30M-S
CCPLP-1-30M-P
1
120
—
—
—
—
CCPLP-2-30M-S
CCPLP-3-30M-S
CCPLP-2-30M-P
CCPLP-3-30M-P
2
3
120
120
—
—
—
—
—
—
—
—
aM fuses:
up to 16 A @ 550 A
20-23 A @ 400V
Switch handle (ganged on 2- and 3-pole versions)
Fuse access door
Open fuse indicating light
Mounting holes for customer
supplied M3 screws
Lockout/tagout provision*
Circuit marking area
Phase barrier
10/32 phil-slot screw or
pressure plate terminal
* Use Brady pin-out device, P/N 90844
Available Bussmann series fuses
Fuse class Catalog symbol
CC
G
FNQ-R, KTK-R, LP-CC
SC
M
BAF, FNM, FNQ, KLM, KTK
gG
aM
C10G
C10M
Data sheet no.10372
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-53
Eaton.com/bussmannseries
11 — Disconnect switches
UL 98 fused disconnect switches up to 800 A
Bussmann series UL 98 and UL 489 fused disconnect switches
“break” and “make” power circuits ON and OFF load.
The switches employ double break contacts per pole that help
ensure complete isolation of the fuse when the switch is in the
"OFF" position.
Agency information
•ꢀ
UL 98, Guide WHTY, File E155130
•ꢀ
UL 489, Guide WJAZ, File E359801
•ꢀ
CSA 22.2 No. 4, File 257020
•ꢀ
Conforms with IEC 60947-3
•ꢀ
NFPA 79
Features
•ꢀ
Make and break power under load
•ꢀ
Double break by pole
•ꢀ
30-60 A DIN-Rail or panel mount, 100-800 A panel mount only
•ꢀ
Up to 200 kA short-circuit current rating
•ꢀ
Finger-safe covers
•ꢀ
Compact footprints available
•ꢀ
Defeatable handles automatically re-latch when the panel door is
closed
•ꢀ
Most disconnect switches are front, right side, flange or direct
handle operable
•ꢀ
NFPA 79 compliant handle kits
Online resources available at Eaton.com/bussmannseries
•ꢀ
CAD drawings
•ꢀ
Instruction sheets
•ꢀ
UL information
Available Bussmann series fuses
Fuse class Catalog symbol/type
LP-CC time-delay, current limiting
FNQ-R time-delay
KTK-R fast-acting
LPJ time-delay, current limiting
JKS fast-acting fuses
DFJ high speed drive fuse
KRP-C time-delay, current limiting
KTU fast-acting
CC
J
L
KLU time-delay
KRP-CL (225-600 A)
11-54
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 98 fused disconnect switches — 30 to 800 A
RDF30CC-3
RDF30J-3 / RDF60J-3-COMP
RDF60J-3
Catalog no.
RDF200J-3
RDF600J-3
Poles
2-pole
—
—
RDF30J-3-
COMP
RDF30J-3N-
COMP
—
UL 489
J
30
RDF30J-2 RDF60J-2-COMP RDF60J-2 RDF100J-2 RDF200J-2
RDF400J-2
RDF400J-3
RDF600J-2
RDF600J-3
RDF800L-2
RDF800L-3
3-pole
RDF30CC-3
RDF30J-3 RDF60J-3-COMP RDF60J-3 RDF100J-3 RDF200J-3
3-pole + neutral
RDF30CC-3N
—
—
—
—
—
—
—
—
4-pole
UL standard
Fuse class
Max fuse/ampacity
Switch type
—
UL 489
CC
30
Compact
RDF30J-4 RDF60J-4-COMP RDF60J-4 RDF100J-4 RDF200J-4
RDF400J-4
UL 98
J
400
Standard
Front/Side ,
Flange
RDF600J-4
UL 98
J
600
Standard
RDF800L-4
UL 98
L
800
Standard
UL 98
J
30
UL 98
J
60
UL 98
J
60
UL 98
J
100
UL 98
J
200
Compact
Standard
Compact
Standard
Standard
Front/Side , Front/Side ,
Flange
Standard
Handle operation
Front
Front
Front/Side
Front/Side
Front/Side
Front , Flange Front , Flange
Flange
UL electrical ratings
Max AC volts
600 Vac
—
—
600 Vac
—
—
600 Vac
250 Vdc
3
3
5.0
7. 5
7. 5
15
20
3
600 Vac
250 Vdc
10
7. 5
15
15
15
30
50
5
600 Vac
250 Vdc
10
7. 5
15
15
15
30
50
5
600 Vac
250 Vdc
10
15
25
30
30
60
75
600 Vac
—
10
25
50
60
60
125
150
—
600 Vac
250 Vdc
10
50
100
125
125
250
350
20
600 Vac
600 Vdc
—
75
150
200
200
400
500
—
600 Vac
600 Vdc
—
Max DC volts*
1-phase, 240
3-phase, 240
3-phase, 480
3-phase, 600
3-phase, 240
3-phase, 480
3-phase, 600
125 Vdc
3
3
75
Std. AC Hp
ratings
5.0
7. 5
7. 5
15
20
—
5.0
7. 5
7. 5
15
20
—
200
250
200
500
500
—
Max. AC Hp
ratings
7. 5
20
DC Hp ratings
250 Vdc
—
—
5
10
10
—
50
—
—
Electrical characteristics
SCCR
Terminal lugs/kits
Mounting torque - lb-in (N•m)
Wire type
100 kA
Integral
—
75°C Cu
14-10, 27
(3.1)
100 kA
Integral
—
75°C Cu
14-10, 27
(3.1)
200 kA
Integral
—
75°C Cu
14-10, 31
(3.5)
100 kA
Integral
—
200 kA
Integral
—
200 kA
Integral
—
200 kA
•
160 (18)
75°C Cu/ Al
200 kA
•
310 (35)
75°C Cu/ Al
200 kA
•
310 (35)
75°C Cu/ Al
200 kA
•
310 (35)
75°C Cu/ Al
75°C Cu
75°C Cu
75°C Cu
12-10, 35.4 12-10, 35.4
Solid
Wire range,
—
—
—
—
14-10, 31 (3.5)
14-6, 31 (3.5)
(4)
(4)
4-600 kcmil,
550 (62),
Dual 1/0-250
kcmil 550 (62)
torque - lb-in
(N•m)
(2) 2-600
kcmil, 375
(42.4)
(2) 2-600
kcmil, 375
(42.4)
14-6 , 31
(3.5)
6-300 kcmil,
275 (31)
14-10 27
(3.1)
12-1, 35.4
(4)
Stranded
14-10 27 (3.1)
10,000
12-1, 35.4 (4)
Mechanical characteristics
Endurances/cycles
Physical characteristics
Dimensions
10,000
10,000
10,000
10,000
10,000
8000
6000
5000
5000
See drawings on product pages
2-pole
—
1.3 (0.6)
—
1.4 (0.6)
3.0 (1.3)
3.8 (1.7)
3.1 (1.4)
4.1 (1.8)
4.1 (1.8)
5.3 (2.4)
4.1 (1.8)
5.3 (2.4)
5.7 (2.6)
7.8 (3.5)
11.4 (5.2)
16.6 (7.6)
31.7 (14.4)
44.2 (20.1) 44.2 (20.1)
31.7 (14.4)
3-pole
Weight - lbs
3-pole +
(kg)
1.4 (0.6)
—
1.5 (0.7)
—
—
—
—
—
—
—
—
—
neutral
4-pole
Environmental
Operating temp. range
Flammability rating
Accessories
4.7 (2.1)
4.8 (2.2)
6.49 (2.9)
6.49 (2.9)
10.8 (4.9)
21.8 (9.9)
56.8 (25.8) 56.8 (25.8)
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
-20-70°C
UL 94-V0
Lug Kit
Integral
•
Integral
•
Integral
•
Integral
•
Integral
•
Integral
•
•
•
•
•
•
•
•
•
Direct
Front
•
•
—
—
—
—
—
—
—
—
selector
Front pistol
Side pistol
Cable
Handles
•
•
•
•
•
•
•
•
•
•
—
•
—
—
—
•
•
•
•
•
—
—
•
•
•
•
•
—
—
—
Flange
Shaft
—
—
•
•
•
•
•
•
•
—
—
—
NFPA through door handle
Shafts c/s - mm
•
5x5
Not
Required
•
•
5x5
Not
Required
•
•
10x10
Not
Required
•
•
10x10
Not
Required
•
•
10x10
Not
Required
•
•
•
•
10x10
10x10
10x10
12X12
12X12
Terminal shrouds
Not Required
•
•
•
•
(1) NO
(1) NC
Volts
•
•
600
10
•
•
600
10
•
•
600
10
•
•
600
10
•
•
600
10
Auxiliary
contacts
•
600
10
•
600
10
•
600
10
•
600
10
•
600
10
AC ratings
Amps
• Available, see product page for details and catalog numbers.
—Not available.
* General purpose only, not photovoltaic rated.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-55
Eaton.com/bussmannseries
11 — Disconnect switches
UL 98 fused rotary disconnect switches — 30 A
Standard 30 amp Class CC and compact 30 amp Class J
For a complete assembly, select:
Switch
Max Hp rating, 3-phase
220/240 440/480 600 AWG size /type
Fuse
class
SCCR
(kA)
100
100
100
Conductor
Amps
30
30
30
30
Poles
3
3 + Ntrl.*
3
3 + Ntrl.*
Catalog no.
RDF30CC-3
RDF30CC-3N
RDF30J-3-COMP
RDF30J-3N-COMP
7. 5
7. 5
7. 5
7. 5
15
15
15
15
20
20
20
20
CC
14-10 Sol/Str
75°C Cu
J
100
* Neutral is switched.
Plus
Direct mount handle - mounts directly to switch, no shaft required
For switch cat. no.
Color
Test function
Padlockable
Catalog no.
DIR-05
RDF30CC-_
Black
Y
Y
RDF30J-_-COMP
DIR-06
OR
External front operated selector handle - shaft required
NEMA type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test function
Padlockable
Defeatable
Catalog no.
H4X-04B
H4X-04R
N
Y
Y
+
Shafts for selector handles
Length - in (mm)
7.9 (200)
12.6 (320)
Mounting depth (X) - in (mm)
4.02~9.65 (102~245)
4.02~14.37 (102~365)
4.02~17.52 (102~445)
Catalog no.
SH1-200
SH1-320
SH1-400
15.7 (400)
OR
External front operated pistol handles - shaft required
NEMA type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test function
Padlockable
Defeatable
Y
Catalog no.
H12-05B
H12-05R
H4X-05B
H4X-05R
H4X-05TB
H4X-05TR
N
Y
Y
or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA type
Color
Test function
Padlockable
Defeatable
Catalog no.
H4X-05BHD
1, 3R, 4, 4X, 12
Black
N
Y
Y
1, 3R, 4, 4X, 12
Red/yellow
H4X-05RHD
+
Shafts for pistol handles
Length - in (mm)
7.9 (200)
12.6 (320)
Mounting depth (X) - in (mm)
4.02~9.65 (102~245)
4.02~14.37 (102~365)
4.02~17.52 (102~445)
Catalog no.
SH2-200
SH2-320
SH2-400
15.7 (400)
OR
NFPA through the door handle kit - to be used with front pistol handle
Color
Test function
Padlockable
Defeatable
N
Catalog no.
H79-1
Red
N
Y
AND...
Auxiliary contacts
Contact
type
NO
No. of Continuous
contacts amp rating
Maximum number of auxiliary contacts per
disconnect switch catalog number
RDF30CC-_: 4 / 8 with BAC-HOLDER2
BAC05 (1) RDF30J-_-COMP: 2 /6 with BAC-
HOLDER2
Voltage (Vac)
600
Catalog no.
BAC05 (1)
1
10
NC
BAC06 (1)
Accepts 4 Auxiliary contacts: BAC05 or
BAC06
Auxiliary contact holder
BAC-HOLDER2 (2)
1
2
11-56
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Dimensions — in (mm)
RDF30CC-_
3.28
83.3
3.78
96
1.12
28.5
1.47 0.59
37.5 15
5.19 (131.8)
Fuse Cover Fully Open
RDF30J-_-COMP
4.13
105
3.89
99
1.47
37.5
0.59
15
1.12
28.5
External front selector handle
Selector handle type
Direction of front operation
Door drilling layout
1.57
40
I
0.11
3
4 Ø 0.27
4 Ø 7
Ø3.07
Ø78
0
1.45
37
Ø 1.22
Ø 31
Ø
Ø
0.88
22.5
H4X-04_
With mounting nut
With 4 Mounting Screws
External front pistol handles
Pistol handle type
Direction of front operation
I
Door drilling layout
Ø 1.46
Ø 37
4 Ø 0.27
Ø3.07
Ø78
4 Ø 7
0
H4X-05__
H12-05__
1.73
44
0.55
14
0.55
14
TEST
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-57
Eaton.com/bussmannseries
11 — Disconnect switches
Standard 30 amp Class J
For a complete assembly, select:
Switch
Max horsepower rating
3-phase
220/240 220/240 440/480 600
1-phase
DC*
125
3
3
3
Fuse
class
SCCR
(kA)
Conductors
Amps
30
Poles
250 AWG size / type
5
Catalog no.
RDF30J-2
RDF30J-3
RDF30J-4
2
3
4
3
-
-
-
-
-
14-10 Sol/14-6 Str
J
200
7. 5
7. 5
15
15
20
20
5
5
75°C Cu
* DC ratings use two poles in series.
PLUS
Direct mount handle - mounts directly to switch, no shaft required
For switch cat. no.
Color
Test function
Padlockable
Catalog no.
DIR-07
All switches
Black
Y
OR
Y - On switch
External front operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test function
Padlockable
Y
Defeatable
Y
Catalog no.
H12-05B
H12-05R
H4X-05B
H4X-05R
H4X-05TB
H4X-05TR
1, 3R, 12
N
Y
1, 3R, 4, 4X, 12
Or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA
Color
Color
Test function
N
Padlockable
Y
Defeatable
Y
Catalog no.
type
Black
Red/yellow
H4X-05BHD
H4X-05RHD
1, 3R, 4, 4X, 12
External right side operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Test function
Padlockable
Y
Defeatable
N/A
Catalog no.
H4X-05SB
H4X-05SR
1, 3R, 4, 4X, 12
N
+
Shafts for pistol handles
Length — in (mm) Mounting depth (X) — in (mm)
Catalog no.
SH5-200
SH5-320
SH5-400
7.9 (200)
5.30~9.06 (135~230)
5.30~13.78 (135~350)
5.30~16.93 (135~430)
12.6 (320)
15.7 (400)
OR
Flange handle (1) - requires shaft operated mechanism or cable operated mechanism + cable
1
2
NEMA type
1, 3R, 4, 12
Flange style
Standard
Test function
Padlockable
Defeatable
Catalog no.
FLH1
FLH2
N
Y
Y
1, 3R, 4, 4X, 12
Chrome plated
Shaft operated flange mechanism (2) - includes shaft
For enclosure depth - in (mm)
6~24 (152~613)
Catalog no.
FLRM
3
Cable operated flange mechanism and cable - must select mechanism (3) and cable (4)
Item / length — in (mm)
Cable mechanism
Catalog no.
FLCM
4
36 (900) cable
FLC36
60 (1500) cable
FLC60
120 (3000) cable
FLC120
OR
NFPA through the door handle kit - to be used with front pistol handle
Color
Test function
Padlockable
Y
Defeatable
N
Catalog no.
H79-2
Red
N
AND...
Auxiliary contacts
Contact
No. of contacts
Continuous amp rating
10
Voltage (Vac)
600
Max. aux contacts per switch
Catalog no.
BAC05
type
NO
1
4
NC
BAC06
11-58
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Dimensions — in (mm)
5.87
149.3
4.84
123
1.41
36
1.46
37.2
1.41
36
Direct mount handle
1.57
40
1.79
45.5
DIR-07
Flange handle
3.50
(88.9)
2.16
Ø0.28
(Ø7.1)
(54.9)
Ø0.50
(Ø12.7)
1.55
1.06
(39.4)
0.86
(26.9)
(21.8)
4.68
(118.9)
5.66
(143.8)
1.00
(25.4)
6.22
(158.0)
1.00 0.88
(25.4) (22.3)
2.32
2.70
(68.6)
(58.9)
7. 10
(180.3)
FLH_
External front and right side pistol handle
Handle type
Direction of front operation Direction of right side operation Door drilling layout
I
I
Ø 1.46
Ø 37
Ø3.07
Ø78
4 Ø 0.27
4 Ø 7
0
0
H4X-05__
H12-05__
1.73
44
0.55
14
TEST
0.55
14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-59
Eaton.com/bussmannseries
11 — Disconnect switches
Compact 60 amp Class J
For a complete assembly, select:
Switch
Max horsepower rating
3-phase
220/240 220/240 440/480 600
1-phase
DC*
Fuse
SCCR
(kA)
Conductor
Amps
60
class Poles
125
5
5
250 AWG size / type
10
10
Catalog no.
2
3
4
10
-
-
-
-
-
RDF60J-2-COMP
RDF60J-3-COMP
RDF60J-4-COMP
14-10 Sol/14-6 Str
75°C Cu
J
100
15
15
30
30
50
50
5
10
* DC ratings use two poles in series.
PLUS
Direct mount handle - mounts directly to switch, no shaft required
For switch cat. no.
Color
Test function
Padlockable
Catalog no.
DIR-07
All switches
Black
Y
Y - on switch
OR
External front operated pistol handles - shaft required
NEMA type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test function
N
Padlockable
Y
Defeatable
Y
Catalog no.
H12-05B
H12-05R
H4X-05B
H4X-05R
H4X-05TB
H4X-05TR
Y
Or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test function
Padlockable
Defeatable
Y
Catalog no.
H4X-05BHD
H4X-05RHD
N
Y
External right side operated pistol handles - shaft required
NEMA type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test function
Padlockable
Y
Defeatable
N/A
Catalog no.
H4X-05SB
H4X-05SR
N
+
Shafts for pistol handles
Length — in (mm) Mounting depth (X) - in (mm)
Catalog no.
SH5-200
SH5-320
SH5-400
7.9 (200)
5.30~9.06 (135~230)
5.30~13.78 (135~350)
5.30~16.93 (135~430)
12.6 (320)
15.7 (400)
OR
Flange handle (1) - requires shaft operated mechanism or cable operated mechanism + cable
1
2
NEMA type
1, 3R, 4, 12
Flange style
Standard
Test function
Padlockable
Defeatable
Catalog no.
FLH1
FLH2
N
Y
Y
1, 3R, 4, 4X, 12
Chrome plated
Shaft operated flange mechanism (2) - includes shaft
For enclosure depth - in (mm)
6~24 (152~613)
Catalog no.
FLRM
3
Cable operated flange mechanism and cable - must select mechanism (3) and cable (4)
Item / length — in (mm)
Cable mechanism
Catalog no.
FLCM
4
36 (900) cable
FLC36
60 (1500) cable
FLC60
120 (3000) cable
FLC120
OR
NFPA through the door handle kit - to be used with selector handle or front pistol handle
Color
Test function
Padlockable
Defeatable
N
Catalog no.
H79-2
Red
N
Y
AND...
Auxiliary contacts
Continuous amp
rating
Contact type
No. of contacts
1
Voltage (Vac)
600
Max. aux contacts per switch
4
Catalog no.
BAC05
NO
NC
10
BAC06
11-60
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Dimensions — in (mm)
4.13
105
3.89
99
1.47
37.5
0.59
15
1.12
28.5
Direct mount handle
1.57
40
1.79
45.5
DIR-07
Flange handle
3.50
(88.9)
Ø0.28
(Ø7.1)
2.16
(54.9)
Ø0.50
(Ø12.7)
1.55
1.06
(39.4)
0.86
(26.9)
(21.8)
4.68
5.66
(143.8)
(118.9)
1.00
(25.4)
6.22
(158.0)
1.00 0.88
(25.4) (22.3)
2.32
2.70
(68.6)
(58.9)
7. 10
(180.3)
FLH_
External front and right side pistol handle
Handle type
Direction of front operation Direction of right side operation Door drilling layout
I
I
Ø 1.46
Ø 37
Ø3.07
Ø78
4 Ø 0.27
4 Ø 7
0
0
H4X-05__
H12-05__
1.73
44
0.55
14
TEST
0.55
14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-61
Eaton.com/bussmannseries
11 — Disconnect switches
Standard 60 amp Class J
For a complete assembly, select:
Switch
Max horsepower rating
3-phase
220/240 220/240 440/480 600
1-phase
DC*
250 size/type
Fuse
SCCR
(kA)
200
200
200
Conductor AWG
Amps
60
class Poles
125
5
5
Catalog no.
RDF60J-2
RDF60J-3
RDF60J-4
2
3
4
10
-
-
-
-
-
10
10
10
12-10 Sol/12-1 Str
75°C Cu
J
15
15
30
30
50
50
5
* DC ratings use two poles in series.
PLUS
Direct mount handle - mounts directly to switch, no shaft required
For switch cat. no.
Color
Test function
Padlockable
Y
Catalog no.
DIR-07
All switches
Black
Y
OR
External front operated pistol handles - shaft required
NEMA type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test function
Padlockable
Y
Defeatable
Y
Catalog no.
H12-03B
H12-03R
H4X-06B
H4X-06R
H4X-06TB
H4X-06TR
N
Y
Or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test function
Padlockable
Defeatable
Y
Catalog no.
H4X-06BHD
H4X-06RHD
N
Y
External right side operated pistol handles - shaft required
NEMA type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test function
Padlockable
Y
Defeatable
N/A
Catalog no.
H4X-06SB
H4X-06SR
N
+
Shafts for pistol handles
Length — in (mm) Mounting depth (X) — in (mm)
Catalog no.
SH5-200
SH5-320
SH5-400
7.9 (200)
5.30~9.06 (135~230)
5.30~13.78 (135~350)
5.30~16.93 (135~430)
12.6 (320)
15.7 (400)
OR
Flange handle (1) - requires shaft operated mechanism or cable operated mechanism + cable
1
2
NEMA type
1, 3R, 4, 12
Flange style
Standard
Test Function
Padlockable
Defeatable
Catalog no.
FLH1
FLH2
N
Y
Y
1, 3R, 4, 4X, 12
Chrome plated
Shaft operated flange mechanism (2) - includes shaft
For enclosure depth — in (mm)
6~24 (152~613)
Catalog no.
FLRM
3
Cable operated flange mechanism and cable - must select mechanism (3) and cable (4)
Item / length — in (mm)
Cable mechanism
Catalog no.
FLCM
4
36 (900) cable
FLC36
60 (1500) cable
FLC60
120 (3000) cable
FLC120
OR
NFPA through the door handle kit - to be used with front pistol handle
Color
Test function
Padlockable
Y
Defeatable
N
Catalog no.
H79-2
Red
N
AND...
Auxiliary contacts
Continuous amp
rating
Max number of aux contacts per
switch
Contact type
No. of contacts
1
Voltage (Vac)
600
Catalog no.
BAC05
NO
NC
10
4
BAC06
11-62
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Dimensions — in (mm)
5.87
4.81
149.3
122.2
1.41
36
1.46
37.2
1.41
36
Direct mount handle
1.57
40
1.79
45.5
DIR-07
Flange handle
3.50
(88.9)
Ø0.28
(Ø7.1)
2.16
(54.9)
Ø0.50
(Ø12.7)
1.55
1.06
(39.4)
0.86
(26.9)
(21.8)
4.68
(118.9)
5.66
(143.8)
1.00
(25.4)
6.22
(158.0)
1.00 0.88
(25.4) (22.3)
2.32
2.70
(68.6)
(58.9)
7. 10
(180.3)
FLH_
External front and right side pistol handle
Handle type
Direction of front operation Direction of right side operation
Door drilling layout
Ø 1.46
I
I
Ø3.07
Ø78
Ø 37
4 Ø 0.27
4 Ø 7
0
H4X-06__
H12-03__
1.77
45
TEST
0.55
14
0.55
14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-63
Eaton.com/bussmannseries
11 — Disconnect switches
Standard 100 amp Class J
For a complete assembly, select:
Switch
Max horsepower rating
3-phase
220/240 220/240 440/480 600 125 250 AWG size/type
1-phase
DC*
Fuse
class Poles
SCCR
(kA)
Conductor
Amps
100
Catalog no.
RDF100J-2
RDF100J-3
RDF100J-4
2
3
4
10
-
-
-
30
30
-
60
60
-
75
75
7. 5
7. 5
7. 5
20
20
20
12-10 Sol/12-1 Str
75°C Cu
J
200
* DC ratings use two poles in series.
PLUS
Direct mount handle - mounts directly to switch, no shaft required
For switch cat.
Color
Test function Padlockable
Catalog no.
DIR-07
no.
All switches
Black
Y
Y
OR
External front operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test function Padlockable
Defeatable
Y
Catalog no.
H12-03B
H12-03R
H4X-06B
H4X-06R
H4X-06TB
H4X-06TR
1, 3R, 12
N
Y
1, 3R, 4, 4X, 12
Y
Or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test function Padlockable
Defeatable
Y
Catalog no.
H4X-06BHD
H4X-06RHD
N
Y
External right side operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Test function Padlockable
Defeatable
N/A
Catalog no.
H4X-06SB
H4X-06SR
1, 3R, 4, 4X, 12
N
Y
+
Shafts for pistol handles
Length — in
(mm)
Mounting depth (X) - in (mm)
Catalog no.
7.9 (200)
12.6 (320)
15.7 (400)
5.30~9.06 (135~230)
5.30~13.78 (135~350)
5.30~16.93 (135~430)
SH5-200
SH5-320
SH5-400
OR
Flange handle (1) - requires shaft operated mechanism or cable operated mechanism + cable
1
2
NEMA type
1, 3R, 4, 12
Flange style
Standard
Test function Padlockable
Defeatable
Catalog no.
FLH1
FLH2
N
Y
Y
1, 3R, 4, 4X, 12
Chrome plated
Shaft operated flange mechanism (2) - includes shaft
For enclosure depth — in (mm)
6~24 (152~613)
Catalog no.
FLRM
3
Cable operated flange mechanism and cable - must select mechanism (3) and cable (4)
Item / length — in (mm)
Cable mechanism
Catalog no.
FLCM
4
36 (900) cable
FLC36
60 (1500) cable
FLC60
120 (3000) cable
FLC120
OR
NFPA through the door handle kit - to be used with front pistol handle
Color
Test function Padlockable
Defeatable
N
Catalog no.
H79-2
Red
N
Y
AND...
Auxiliary contacts
Continuous amp
rating
Max number of aux contacts
per switch
Contact type
No. of contacts
1
Voltage (Vac)
600
Catalog no.
BAC05
NO
NC
10
4
BAC06
11-64
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Dimensions — in (mm)
5.87
149.3
4.81
122.2
1.41
36
1.46
37.2
1.41
36
Direct mount handle
1.57
40
1.79
45.5
DIR-07
Flange handle
3.50
(88.9)
Ø0.28
(Ø7.1)
2.16
(54.9)
Ø0.50
(Ø12.7)
1.55
1.06
(39.4)
0.86
(26.9)
(21.8)
4.68
(118.9)
5.66
(143.8)
1.00
(25.4)
6.22
(158.0)
1.00 0.88
(25.4) (22.3)
2.32
2.70
(68.6)
(58.9)
7. 10
(180.3)
FLH_
External front and right side pistol handle
Handle type
Direction of front operation Direction of right side operation
Door drilling layout
Ø 1.46
I
I
Ø3.07
Ø78
Ø 37
4 Ø 0.27
4 Ø 7
0
H4X-06__
H12-03__
1.77
45
TEST
0.55
14
0.55
14
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-65
Eaton.com/bussmannseries
11 — Disconnect switches
Standard 200 and 400 amp Class J
For a complete assembly, select:
Switch
Max horsepower rating
3-phase
220/240 220/240 440/480 600
1-phase
DC*
Fuse
class
SCCR
(kA)
Amps
200
Poles
125
-
-
250
-
-
Catalog no.
RDF200J-2
RDF200J-3
RDF200J-4
RDF400J-2
RDF400J-3
RDF400J-4
2
3
4
2
3
4
10
-
-
10
-
-
-
-
-
60
60
-
125
125
-
150
150
-
-
-
J
200
20
20
20
50
50
50
400
125
125
250
250
350
350
* DC ratings use two poles in series.
+
Terminal lug kit
Switch amps
Poles
Lugs per kit
AWG wire / type
Catalog no.
LUG1-2
LUG1-3
LUG1-4
LUG2-2
LUG2-3
LUG2-4
2
3
4
2
3
4
2
3
4
2
3
4
6-300 kcmil
75°C Cu/Al
200
4-600 kcmil or dual 1/0-250 kcmil
75°C Cu/Al
400
PLUS
Direct mount handle - mounts directly to switch, no shaft required
For switch cat. no.
Color
Test function
Padlockable
Catalog no.
DIR-07
All switches
Black
Y
Y
OR
External front operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test function
Padlockable
Defeatable
Y
Catalog no.
H12-03B
H12-03R
H4X-06B
H4X-06R
H4X-06TB
H4X-06TR
1, 3R, 12
N
Y
1, 3R, 4, 4X, 12
Y
Or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Test function
Padlockable
Defeatable
Catalog no.
H4X-06BHD
H4X-06RHD
1, 3R, 4, 4X, 12
N
Y
Y
External right side operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Test function
Padlockable
Defeatable
N/A
Catalog no.
H4X-06SB
H4X-06SR
1, 3R, 4, 4X, 12
N
Y
+
Shafts for pistol handles
Length — in (mm) Mounting depth (X) — in (mm)
Catalog no.
SH5-200
200 A: 5.70-9.06 (145-230)
7.9 (200)
400 A: 7.87-10.24 (200-260)
200 A: 5.70-13.78 (145-350)
12.6 (320)
SH5-320
SH5-400
400 A: 7.87-16.93 (200-380)
200 A: 5.70-16.93 (145-430)
15.7 (400)
400 A: 7.87-18.10 (200-460)
OR
Flange handle (1) 200 A only - requires shaft operated mechanism or cable operated mechanism +
cable
1
2
NEMA type
1, 3R, 4, 12
Flange style
Standard
Test function
Padlockable
Defeatable
Catalog no.
FLH1
N
Y
Y
1, 3R, 4, 4X, 12
Chrome plated
FLH2
Shaft operated flange mechanism (2) 200 A only - includes shaft
For enclosure depth — in (mm)
6~24 (152~613)
Catalog no.
FLRM
3
Cable operated flange mechanism and cable 200 A only - must select Mechanism (3) and Cable (4)
Item — in (mm)
Cable mechanism
36 (900) cable
Catalog no.
FLCM
FLC36
4
60 (1500) cable
120 (3000) cable
FLC60
FLC120
11-66
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
OR
NFPA through the door handle kit - to be used with front pistol handle
Use with switch
RDF200J-_
Color
Red
Test function
N
Padlockable
Y
Defeatable
N
Catalog no.
H79-2
RDF400J-_
H79-3
AND...
Auxiliary contacts
Max number of
aux contacts per
switch catalog
number
RDF200J-__: 4
RDF400J-__: 8
Continuous amp
rating
Contact type
No. of contacts
1
Voltage (Vac)
600
Catalog no.
NO
NC
BAC05
BAC06
10
AND...
Terminal shrouds - includes terminal shroud for lineside or loadside
Switch amps
Poles
2
3
Catalog no.
TSH8-2TB
TSH8-3TB
200
4
TSH8-4TB
2
3
TSH9-2TB
TSH9-3TB
400
4
TSH9-4TB
Dimensions — in (mm)
RDF200J-3
RDF400J-3
7.72
196.2
7.08
180
6.61
168
4.37
111.1
10.19 (3P) - 12.79 (4P)
259 (3P) - 325 (4P)
6.18
157
0.98
24.9
1.41
36
3.26
83
1.96
50
5.11
130
2.59
66
2.59
66
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-67
Eaton.com/bussmannseries
11 — Disconnect switches
Dimensions — in (mm)
DIR-07 direct mount handle
FLH_ flange handle
3.50
(88.9)
1.57
40
1.79
45.5
Ø0.28
(Ø7.1)
2.16
(54.9)
Ø0.50
(Ø12.7)
1.55
1.06
(39.4)
0.86
(26.9)
(21.8)
4.68
5.66
(143.8)
(118.9)
1.00
(25.4)
6.22
(158.0)
1.00 0.88
(25.4) (22.3)
2.32
2.70
(68.6)
(58.9)
7. 10
(180.3)
External front and right side pistol handle
Handle type
Direction of front operation Direction of right side operation
Door drilling layout
Ø 1.46
I
I
Ø3.07
Ø78
Ø 37
4 Ø 0.27
4 Ø 7
0
H4X-06__
H12-03__
1.77
45
TEST
0.55
14
0.55
14
Terminal lugs
200 A (LUG1-__)
400 A (LUG2-__)
Ø 0.4
Ø 4.7
0.45
Ø11.6
2.8
0.63
71.5
15.88
1.52
38.8
0.46
11.68
11-68
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Standard 600 amp Class J and 800 amp Class L
For a complete assembly, select:
Switch
Max horsepower rating, 3-phase
Fuse
Amps
600
class
Poles
SCCR ()kA)
200
220/240
440/480
600
-
Catalog no.
RDF600J-2
RDF600J-3
RDF600J-4
RDF800L-2
RDF800L-3
RDF800L-4
2
3
4
2
3
4
-
-
J
200
200
-
400
400
-
500
500
-
800
L
200
200
500
500
500
500
+
Terminal lug kit
Switch amps
Poles
2
Lugs per kit
2
Conductor AWG size / type
Catalog no.
LUG5-2
(2) 2-600 kcmil
75°C Cu/ Al
600-800
3
4
3
4
LUG5-3
LUG5-4
PLUS
Direct mount handle - mounts directly to switch, no shaft required
Test
For switch cat. no.
All switches
Color
Black
Padlockable
Y
Defeatable
N
Catalog no.
DIR-08
function
Y
OR
External front operated pistol handles - shaft required
Test
NEMA type
Color
Padlockable
Y
Defeatable
Y
Catalog no.
function
Black
Red/yellow
H4X-07B
H4X-07R
1, 3R, 4, 4X, 12
N
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA
type
Test
Or
Color
Padlockable
Y
Defeatable
Y
Catalog no.
H4X-07BHD
function
Black
1, 3R, 4, 4X, 12
N
Red/yellow
H4X-07RHD
Shafts for pistol handles
+
Length — in (mm) Mounting depth (X) — in (mm)
Catalog no.
SH7-200
7.9 (200)
10.63~11.97 (270~304)
10.63~16.69 (270~424)
10.63~19.84 (270~504)
12.6 (320)
15.7 (400)
SH7-320
SH7-400
OR
NFPA through the door handle kit - to be used with front pistol handle
Test func-
For switch cat. no.
All switches
Color
Padlockable
Y
Defeatable
N
Catalog no.
H79-4
tion
Red
N
AND...
Auxiliary contacts
No. of
Continuous
Voltage
(Vac)
Max number of aux contacts per
switch
Contact type
Catalog no.
contacts amp rating
NO
NC
BAC05
BAC06
1
10
600
8
AND...
Terminal shrouds - includes terminal shroud for lineside or loadside
Switch amps
Poles
Catalog no.
TSH10-2TB
2
600-800
3
4
TSH10-3TB
TSH10-4TB
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-69
Eaton.com/bussmannseries
11 — Disconnect switches
Dimensions — in (mm)
RDF600J-3 and RDF800L-3
min 10.43
min 265
11.18 (3P) - 14.88 (4P)
284 (3P) - 378 (4P)
9.84
250
6.10
155
1.34
34
2.56
65
3.12
79.5
0.43
11
0.27
7
Ø 0.51
Ø13
0.35
9
2.32
59
2
51
3.7
94
3.7
94
14.96
380
18.58
472
14.33 (3P) - 18.03 (4P)
364 (3P) - 458 (4P)
Fuse Cover Fully Open
Dir-08 drect mount handle
2.36
60
3.35
85
External front pistol handle
Direction of front operation
I
Door drilling layout
Handle type
Ø3.07
Ø78
Ø 1.46
Ø 37
4 Ø 0.27
4 Ø 7
0.55
14
0.55
14
H4X-07__
61
Terminal lugs
600 to 800 A (LUG5-__)
3.76
95.5
0.40
Ø10.2
3.15
80
11-70
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 98 non-fused rotary disconnect switches — 30
to 1200 amps
Bussmann series UL 98 non-fused rotary disconnect switches are
versatile switches that “break” and “make” power circuits ON and
OFF load.
Agency information
•ꢀ
UL 98, Guide WHTY, File E155130
•ꢀ
CSA 22.2 No. 4, File 257020
•ꢀ
Conforms with IEC 60947-3
Features
Related Bussmann series products
•ꢀ
Make and break power under load
•ꢀ
•ꢀ
•ꢀ
Fuse blocks
Up to 200 kA SCCR
Modular Class H(K), J and RK fuse blocks up to 600 A
Modular Class H(K), J and RK power distribution fuse blocks up to 400 A
Modular, finger-safe CH Class CC and J, and UL supplemental and IEC
10x38mm DIN-Rail holders up to 60 A
Panel mount (30-100 A compact DIN-Rail or panel mount)
Disconnect switches are front, right side and direct handle
operable (30-100 A)
•ꢀ
•ꢀ
Finger-safe (30-100 A compact only)
Fully visualized breaking (100-1200 A)
Finger-safe Optima Class CC, UL supplemental and IEC 10x38mm DIN-
Rail/panel mount holders up to 30 A
Finger-safe Optima™ Class CC, UL supplemental and IEC 10x38mm
DIN-Rail/panel mount protection modules up to 30 A
Online resources
Visit Eaton.com/bussmannseries for:
•ꢀ
CAD drawings
•ꢀ
Instruction sheets
•ꢀ
UL information
IEC specifications
RD30-3
RD200-3
RD600-3
Catalog no.
RD30-3 RD60-3 RD100-3 RD100-3-SCCR RD200-3 RD400-3 RD600-3 RD800-3 RD1000-3 RD1200-3
3-pole
4-pole
—
30
800
8
—
60
800
8
—
100
800
8
—
100
1000
8
RD200-4 RD400-4 RD600-4 RD800-4 RD1000-4 RD1200-4
Thermal current Ith @ 40°C (A)
Rated insulation voltage Ui (V)
Rated impulse withstand voltage Uimp (kV)
Rated operation currents Ie (A)
200
1000
8
400
1000
8
—
1000
12
—
1000
12
—
1000
12
—
1000
12
Load duty
Rated voltage (Vac)
A 1
32
A 1
63
A 1
A 1
A 1
A 1
A 1
A 1
A 1
A 1
category
AC-22 A
AC-23 A
AC-22 A
AC-23 A
1200
1000
630
400
690
100
630
800
1000
400
315
100
200
80
63
500
200
630
400
630
400
400
Operational power (Vac) in AC-23 (kW)
400 V w/o prebreak AC 1, 2
51
63
90
100
140
185
220
280
185
355
450
185
450
560
400
15
560
400
560
400
500 V w/o prebreak AC 1, 2
30
12
45
12
690 V w/o prebreak AC 1, 2
18.5
Overload capacity (Ue 415 Vac)
Rated short-circuit making capacity Icm (kA peak) 3
Fuse protected short-circuit withstand
(kA RMS prospective)
Short-circuit current (kA) 3
Associated fuse rating (A) 3
12
17. 6
32
48
48
75
48
75
50
32
50
63
25
100
200
100
200
400
100
630
100
800
100
1000
100
1250
200
Connection
Minimum Cu cable cross section (mm2)
Minimum Cu busbar section (mm2)
Maximum Cu cable section (mm2)
2.5
—
70
2.5
—
70
10
—
70
35
—
300
70
—
300
185
—
600
2x150
2x30x5
—
2x185
2x40x5
—
2x240
2x50x5
—
—
2x60x5
—
1 A/B: Category with index A = frequent operation; category with index B = infrequent operation.
2 The power value is given for information only; the current values vary from one manufacturer to another.
3 For a rated operating voltage, Ue = 400 Vac.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-71
Eaton.com/bussmannseries
11 — Disconnect switches
UL specifications
RD30-3
RD200-3
RD600-3
Catalog no.
RD100-3-
SCCR
—
UL 98
100 A
Standard
Front
3-pole
4-pole
UL standard
Max ampacity
Switch type
Handle operation
UL electrical ratings
Max voltage (AC)
Max voltage (DC)
RD30-3
—
UL 98
30 A
Compact
Front/Side
RD60-3
—
UL 98
60 A
Compact
Front/Side Front/Side
RD100-3
—
UL 98
100 A
RD200-3
RD200-4
UL 98
200 A
Standard
Front
RD400-3
RD400-4
UL 98
400 A
Standard
Front
RD600-3
RD600-4
UL 98
600 A
Standard
Front
RD800-3 RD1000-3 RD1200-3
RD800-4 RD1000-4 RD1200-4
UL 98
800 A
Standard
Front
UL 98
1000 A
Standard
Front
UL 98
1200 A
Standard
Front
Compact
600 Vac
—
2
600 Vac
—
600 Vac
—
600 Vac
250 Vdc
—
600 Vac
250 Vdc
—
600 Vac
—
—
600 Vac
250 Vdc
—
600 Vac
—
600 Vac
—
600 Vac
—
1-phase, 120
3
5
—
—
—
1-phase, 240
3-phase, 240
3-phase, 480
3-phase, 600
125
5
10
20
40
50
—
—
10
20
50
50
—
—
10
30
75
100
—
10
75
150
200
—
—
—
—
—
—
Max. AC Hp
ratings
10
20
25
—
—
125
250
350
—
200
400
350
20
200
500
500
—
200
500
500
—
200
500
500
—
DC Hp ratings
250
—
—
—
50
—
—
—
Electrical characteristics
SCCR with fuse (kA)
Fuse class
100
J
100
J
25 /100*
J
200
J
200
J
200
J
200
J
100
L
100
L
100
L
Max. fuse rating (A)
Terminal lugs/kits
Lug mounting torque - lb-in
(N•m)
30
Integral
60
Integral
100
Integral
10A
•
200
•
400
•
600
•
800
•
1000
•
1200
•
LUG2-_ 310 (35)
LUG3-_ 398 (45)
—
—
—
160 (18)
75°C Cu/ Al
—
160 (18)
75°C Cu/ Al
—
310 (35)
310 (35)
310 (35)
310 (35)
75°C Cu/
Al
Wire type
Solid
75°C Cu
75°C Cu
75°C Cu
75°C Cu/ Al
—
75°C Cu/ Al
75°C Cu/ Al 75°C Cu/ Al
12-10,
35.4 (4)
12-10,
35.4 (4)
12-10,
35.4 (4)
—
—
—
—
(2) 2-600
(4) 2-600
(4) 2-600
(4) 2-600
10-1,
35.4 (4)
10-1,
35.4 (4)
10-1,
35.4 (4)
6-300 kcmil, 6-300 kcmil,
275 (31) 275 (31)
LUG2-_ 4-600
kcmil, 550 (62)
kcmil, 375 kcmil, 375 kcmil, 375 kcmil, 375
(42.4)
(42.4)
(42.4)
(42.4)
Wire range
and torque -
lb-in (N•m)
1/0, 39.8
(4.5)
1/0, 39.8
(4.5)
1/0, 39.8
(4.5)
2/0, 44.3
(5)
Dual 1/0-250
kcmil, 550 (62)
LUG3-_: (2) 6-2,
200 (22.6)
Stranded
2/0, 44.3 (5) 2/0, 44.3 (5)
(2) 1-350 kcmil,
375 (42.4)
Mechanical characteristics
Endurances/Cycles
10,000
10,000
10,000
10,000
8000
6000
6000
3500
3500
3500
Physical characteristics
Dimensions
See drawings on product pages
3-pole
4-pole
1.3 (0.6)
—
1.3 (0.6)
—
1.3 (0.6)
—
4.2 (1.91)
4.2 (1.91)
5.0 (2.3)
10.0 (4.6)
12.3 (5.6)
18.1 (8.2)
23.9 (10.9) 25.3 (11.5) 25.3 (11.5)
19.6 (8.9)
19.6 (8.9)
19.6 (8.9)
25.3 (11.5)
Weight - lbs
(kg)
—
Environmental
-20 to
70°C
UL 94-V0
Operating Temperature
-20 to 70°C -20 to 70°C
-20 to 70°C
UL 94-V0
-20 to 70°C
UL 94-V0
-20 to 70°C
UL 94-V0
-20 to 70°C -20 to 70°C -20 to 70°C -20 to 70°C
Flammability Rating
UL 94-V0
UL 94-V0
UL 94-V0
UL 94-V0
UL 94-V0
UL 94-V0
Accessories
3-pole
Lug kit cat. no.
4-pole
Integral
—
Integral
—
Integral
—
•
—
•
•
•
•
•
•
•
•
•
•
•
•
NEMA 1,
•
•
•
•
•
•
•
•
•
•
•
•
—
—
—
—
3R, 12
NEMA 1, 3R,
4, 4X, 12
Direct
Front Pistol
Front or Side
Selector
•
•
•
•
Handles
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
—
—
—
—
—
—
—
Shaft c/s - mm
Shaft guide
Shrouds
5x5
•
•
5x5
•
•
5x5
•
•
10x10
•
•
10x10
•
•
10x10
•
•
12x12
•
•
12x12
•
•
12x12
••
•
12x12
•
•
Additional pole accessory
•
•
•
•
•
•
•
•
•
—
•
—
—
•
—
—
•
—
—
•
—
—
•
—
—
•
—
—
•
—
NO + NC
(2) NO
Auxiliary
contacts
• Available, see product page for details and catalog numbers.
—Not available.
* 25 kA @ 600 Vac, 100 kA @ 480 Vac.
11-72
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 98 non-fused rotary disconnect switches — 30, 60 and compact 100 A
For a complete assembly, select:
Switch
Max horsepower rating
1-phase
120 220/240 220/240
3-phase
440/480
Conductor
Amps
30
60
Poles
3
SCCR (kA)
100
600 AWG size/type
25
50
50
Catalog no.
RD30-3
RD60-3
2
3
5
5
10
10
10
20
20
20
40
50
10-2/0 Str/12-10 Sol
75°C Cu
100
25/100*
RD100-3
* 100 kA @480 Vac, 25 kA @ 600 Vac.
PLUS
Direct mount handle - mounts directly to switch, no shaft required
For switch cat. no.
All switches
Color
Black
Test function
N
Padlockable
Y - On Switch
Catalog no.
DIR-02
OR
External front or right side operated selector handles - shaft required
1
2
Handle
NEMA type
Color
Test function
N
Padlockable
Y
Catalog no.
length
Short
Short
Long
Long
Black
Red/yellow
Black
H4X-01B (1)
H4X-01R (1)
H4X-02B (2)
H4X-02R (2)
1, 3R, 4, 4X, 12
Red/yellow
Or
External front operated pistol handles - shaft required
Handle
NEMA type
Color
Test function
N
Padlockable
Defeatable
Y
Catalog no.
length
Black
Red/yellow
—
—
H4X-03B
H4X-03R
1, 3R, 4, 4X, 12
Y
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
Handle
NEMA type
Color
Test function
N
Padlockable
Y
Defeatable
Y
Catalog no.
length
Black
Red/yellow
—
—
H4X-03BHD
H4X-03RHD
1, 3R, 4, 4X, 12
+
Shafts for selector handles
Length — in (mm) Mounting depth (X) — in (mm)
Catalog no.
SH4-150 (1)
SH4-200 (1)
SH4-320 (1)
1
5.9 (150)
7.9 (200)
12.6 (320)
3.50~7.60 (89~193)
3.50~9.50 (89~241)
3.50~14.9 (89~378)
Shafts for pistol handles
Length — in (mm) Mounting depth (X) - in (mm)
Catalog no.
SH3-200 (2)
SH3-320 (2)
SH3-400 (2)
2
7.9 (200)
3.30~7.40 (84~188)
3.30~9.30 (84~236)
3.30~14.7 (84~373)
12.6 (320)
15.7 (400)
+
Shaft guide for selector handles
Catalog no.
SH-GUIDE1
Required for 12.6" (320mm) long shafts, optional for other lengths
Shaft guide for pistol handles
Catalog no.
SH-GUIDE2
Required for 15.7î (400mm) long shafts, optional for other lengths
AND...
Auxiliary contacts
Continuous amp
Max number of units per
switch
2 (1 per side/4 contacts
total)
2 (1 per side/4 contacts
total)
Contact type
NO + NC
NO
No. of contacts
Voltage (Vac)
240
Catalog no.
BAC01
rating
1 of each
2
10
BAC02
AND...
Terminal shrouds - includes terminal shroud for both lineside and loadside
Switch
Poles
Location on switch
Lineside and loadside
Catalog no.
amps
1 (for switched 4th pole)
3
TSH3-1TB
TSH3-3TB
All switch-
es
AND...
Switched 4th Pole - converts 3-pole switch to 4-pole
Switch amps
Catalog no.
POLE98-30
POLE98-60
POLE98-100
30
60
100
Auxiliary contact
configurations
Possible 4th pole
configurations
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-73
Eaton.com/bussmannseries
11 — Disconnect switches
Dimensions - in (mm)
Direct handle operation
External front operation
External right side operation
3.94 min./14.65 max.
1.42
36
2.95
100 min./372 max.
3.07
78
75
3.19
81
2.52
64
3.07
2.52
1
1.42
36
1.18 min./7.91 max.
1.02
78
64
2
30 min./201 max.
26
1.02
26
0.51
13
1
1.99
50.6
2
1
1
2
2
0.24
6
0.35 1.02 1.02
26 26
0.35
1.02
26 8.8
8.8
2.09
53
0.34 1.02
8.8 26
1.02
26
M5
1.02
0.34
0.26
6
M5
26 8.8
2.08
53
1. Position for 1 switched 4th pole (1 per device max.) or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 Auxiliary contacts, or 3 Auxiliary contacts + one switched 4th pole.
External front/right side operated selector handle, front operated pistol handle
Handle type
Door drilling layouts
Ø3.07
Ø78
1.57
40
0.11
3
4 Ø 0.27
4 Ø 7
Direction of
front operation
Direction of
right side operation
Selector
H4X-01_
1.42
36
I
I
Ø3.07
Ø78
Ø 1.22
Ø 31
Ø
Ø
0.88
22.5
0
0
With mounting nut
With 4 Mounting Screws
Selector
H4X-02_
1.45
37
1.57
40
4 Ø 0.27
4 Ø 7
H4X-03_ with 4 mounting screws
Pistol
H4X-03_
Ø 1.45in/37mm screw clip (from front)
Ø 1.22in/31mm screw (from rear)
11-74
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 98 non-fused rotary disconnect switches—100, 200 and compact 400 A
For a complete assembly, select:
Switch
Max horsepower rating
1-phase
SCCR (kA) 220/240
3-phase
440/480
75
Amps
100
Poles
3
220/240
30
75
600
100
200
200
350
350
Catalog no.
RD100-3-SCCR
RD200-3
RD200-4
RD400-3
10
10
150
200
400
4
3
4
200
10
-
-
75
125
125
150
250
250
RD400-4
+
Terminal lug kit
Switch
amps
Poles
Lugs per kit
Conductor AWG size/type
Catalog no.
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
LUG1-2
LUG1-3
LUG1-4
LUG2-2
LUG2-3
LUG2-4
LUG3-2
LUG3-3
LUG3-4
6-300 kcmil
75°C Cu/ Al
100-200
4-600 kcmil or Dual 1/0-250 kcmil
75°C Cu/ Al
400
(2) 6-350 kcmil
75°C Cu/ Al
PLUS
Direct mount handle - mounts directly to switch, no shaft required
Test
For switch cat. no.
All switches
Color
Black
Padlockable
Y
Catalog no.
DIR-03
function
N
OR
External front operated pistol handles - shaft required
Test
NEMA type
1, 3R, 12
Color
Padlockable Defeatable Catalog no.
function
Black
Red/yellow
Black
H12-03B
H12-03R
N
Y
Y
H4X-06B
H4X-06R
Or
1, 3R, 4, 4X, 12
Red/yellow
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
Test
NEMA type
Color
Padlockable Defeatable Catalog no.
H4X-06BHD
function
Black
Red/yellow
1, 3R, 4, 4X, 12
N
Y
Y
H4X-06RHD
+
+
Shafts for pistol handles
Length — in (mm)
7.9 (200)
12.6 (320)
Mounting depth (X) - in (mm)
5.31~10.43 (135~265)
5.31~15.16 (135~385)
5.31~18.31 (135~465)
Catalog no.
SH5-200
SH5-320
SH5-400
15.7 (400)
Shaft Guide
Catalog no.
SH-GUIDE2
Required for 15.7î (400mm) long shafts, optional for other lengths
AND...
Auxiliary contacts
Contact
type
No. of
contacts
Voltage
Vac
Max number of aux
contacts per switch
Continuous amp rating
Catalog no.
NO + NC
NO + NC
NO + NC
NO + NC
BAC03*
BAC04*
BAC11*
BAC12*
10.1
125-250
1 of each
2
1
125
* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.
AND...
Terminal shrouds - includes terminal shroud for Lineside or loadside
Switch
Poles
Location on switch
Catalog no.
amps
Lineside
Loadside
Lineside or loadside
Lineside
Loadside
Lineside or loadside
TSH4-3T
TSH4-3B
TSH4-4TB
TSH5-3T
TSH5-3B
TSH5-4TB
3
4
3
4
100-200
400
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-75
Eaton.com/bussmannseries
11 — Disconnect switches
Dimensions — in (mm)
M
J1
U
Z
Y
1
W
R1
R2
T
AD
C
F
Switch Overall
amps dim. C
Terminal shrouds
Switch body
Switch mounting
M 3p. M 4p. R1
5.31 0.35 0.27
(210) (135) (9) (7)
8.27 5.31 0.35 0.27
(210) (135) (9) (7)
10.6 7.67 0.35 0.27
(270) (195) (9) (7)
Connection
AC
10.1
(256)
10.1
(256)
16
AD
F 3p.
7.09
(180)
7.09
(180)
9.05
(230)
F 4p.
9.06
(230)
9.06
(230)
11.4
H
J1 3p. J1 4p.
K
1.8
N
R2
T
U
V
W
Y
Z
A A
6.3
(160)
6.3
(160)
10.2
(260)
AC
0.6
(15)
0.6
(15)
0.8
(20)
4.22
(107)
4.22
(107)
6.53
(166)
2.17
(55)
2.17
(55)
2.95
(75)
4.13
6.3
(160)
6.3
(160)
8.26
(210)
8.27
1.97
(50)
1.97
(50)
2.56
(65)
0.98
(25)
0.98
(25)
1.77
(45)
1.18
(30)
1.18
(30)
1.97
(50)
0.43 0.14 1.35
(11) (4) (34)
0.43 0.14 1.35
100
200
400
3.72 (95)
3.72 (95)
4.92 (128)
3.05 (78)
(105)
4.13
(105)
5.31
(135)
(46)
1.8
(46)
2.65
(68)
3.05 (78)
4.15 (115)
(11)
0.43
(13)
(4)
0.2
(5)
(34)
2.08
(53)
(406)
(290)
DIR-03 direct mount handle
External front handle
1.57
40
1.79
45.5
Handle type
Direction of front operation
I
Door drilling layout
Ø 1.46
Ø3.07
Ø78
Ø 37
4 Ø 0.27
4 Ø 7
H4X-06__
H12-03__
1.77
45
TEST
0.55
0.55
14
14
Terminal lugs
0.88
Ø 0.4
Ø 4.7
73.15
2.31
58.67
0.45
Ø11.6
0.53
13.46
2.8
0.63
71.5
15.88
1.52
38.8
0.46
11.68
1.19
30.23
0.25
6.35
LUG1-_ 100 to 200 A
LUG2-_ 400 A
LUG3-_ 400 A
11-76
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 98 non-fused rotary disconnect switches — 600, 800, 1000 and 1200 A
For a complete assembly, select:
Switch
Max horsepower rating
3-phase
440/480
400
400
500
500
500
500
500
DC*
SCCR
(kA)
Amps
600
Poles
220/240
240
240
200
200
200
200
200
200
600
350
350
500
500
500
500
500
500
125
20
20
-
-
-
-
-
-
250 Catalog no.
3
4
3
4
3
4
3
4
50
RD600-3
RD600-4
RD800-3
RD800-4
RD1000-3
RD1000-4
RD1200-3
RD1200-4
200
50
-
-
-
-
-
-
800
1000
1200
100
500
* DC ratings use two poles in series.
+
Terminal lug kit
Conductor AWG
size/type
(2) 2-600 kcmil
75°C Cu/ Al
Switch amps
600
Poles
Lugs per kit
Lugs required per pole
1
Catalog no.
3
4
3
4
3
4
6
8
LUG5-3
LUG5-4
LUG6-6
LUG6-8
(4) 2-600 kcmil
75°C Cu/ Al
800-1200
2
PLUS
Direct mount handle - mounts directly to switch, no shaft required
For switch cat. no.
Color
Test function
Padlockable
Catalog no.
DIR-04
All switches
Black
N
Y
OR
External front operated pistol handles - shaft required
1
3
2
4
NEMA type
Color
Black
Test function Padlockable
Defeatable
Y
Catalog no.
H4X-07B (1)
H4X-07R (1)
H4X-08B (2)
H4X-08R (2)
Red/yellow
Black
1, 3R, 4, 4X, 12
N
Y
Red/yellow
Or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA type
Color
Black
Test function Padlockable
Defeatable
Y
Catalog no.
H4X-07BHD (3)
H4X-07RHD (3)
H4X-08BHD (4)
H4X-08RHD (4)
Red/yellow
Black
Red/yellow
1, 3R, 4, 4X, 1
N
Y
+
+
Shafts for pistol handles
Length — in (mm)
7.9 (200)
12.6 (320)
15.7 (400)
Mounting depth (X) — in (mm)
8.70~13.50 (221~343)
8.70~18.23 (221~463)
8.70~21.38 (221~543)
Catalog no.
SH6-200
SH6-320
SH6-400
Shaft guide
Catalog no.
SH-GUIDE2
Required for 15.7" (400mm) long shafts, optional for other lengths
AND...
Auxiliary contacts
Max number of aux contacts
per switch
Contact type No. of contacts Continuous amp rating Voltage (Vac)
Catalog no.
NO + NC
NO + NC
NO + NC
NO + NC
1 of each
1 of each
1 of each
1 of each
BAC03*
BAC04*
BAC11*
BAC12*
10.1
1
125-250
125
2
* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.
AND...
Terminal shrouds* — includes terminal shroud for lineside or loadside
Switch amps
Poles
Location on switch
Catalog no.
TSH6-3TB
TSH6-4TB
TSH7-3TB
TSH7-4TB
3
4
3
4
600
Lineside or loadside
800-1200
* Shroud for lineside included with switch.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-77
Eaton.com/bussmannseries
11 — Disconnect switches
Dimensions — in (mm)
600 A
800 to 1200 A
Switch body
H
Switch mounting
M 4p.
6.59 (168) 10.03 (255) 13.19 (335) 6.88 (175) 2.34 (60) 1.1 (28) 12.6 (320) 1.85 (47)
Connection
Switch
amps
Terminal
shrouds B
F 3p.
F 4p.
J 3p.
J 4p.
M 3p.
N
N1
N2
A A
Z
600
18.12 (460)
11 (280)
14.17 (360) 5.5 (140)
5 (128)
800
18.12 (460) 14.64 (372) 19.37 (492) 5.5 (140) 6.83 (174) 9.19 (234) 13.66 (347) 18.38 (467) 6.88 (175) 2.34 (60) 1.1 (28)
18.12 (460) 14.64 (372) 19.37 (492) 5.5 (140) 6.83 (174) 9.19 (234) 13.66 (347) 18.38 (467) 6.88 (175) 2.34 (60) 1.1 (28)
18.12 (460) 14.64 (372) 19.37 (492) 5.5 (140) 6.83 (174) 9.19 (234) 13.66 (347) 18.38 (467) 6.88 (175) 2.34 (60) 1.1 (28)
13 (330)
13 (330)
13 (330)
1.85 (47)
1.85 (47)
1.85 (47)
1000
1200
DIR-04 Direct mount handle
External front pistol handles
2.36
60
Direction of Front Operation
Handle Type
I
Ø3.07
Ø78
Door drilling layout
Ø 1.46
Ø 37
4 Ø 0.27
4 Ø 7
H4X-07__
2.4
3.35
85
61
Terminal lugs
I
Ø3.07
Ø78
0.55
14
0.55
14
0
2.36
60
H4X-08__
LUG5-__, LUG6-__ 600 to 1200 A
3.76
95.5
0.40
Ø10.2
3.15
80
11-78
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 508 non-fused rotary disconnect switches —
16 to 80 A
Eaton UL 508 load break disconnect switches allow safe control and
safe disconnection of any motor application or to isolate a circuit
within the panel.
These disconnect switches are compact and offer a wide variety of
accessories like 4th poles, Auxiliary contacts, door mounting and
6/8-Pole kits.
Features
•ꢀ
Suitable for motor disconnect
•ꢀ
DIN-Rail or panel mount
•ꢀ
Door mount option
•ꢀ
Disconnect switches are front, right side or direct handle operable
•ꢀ
Finger-safe
Agency information
Related Bussmann series products
•ꢀ
UL 508, Guide NLRV, File E155129
Fuse blocks
Modular Class H(K), J and RK fuse blocks up to 600 A
Modular Class H(K), J and RK power distribution fuse blocks up to 400 A
Modular, finger-safe CH Class CC and J, and UL supplemental and IEC
10x38mm DIN-Rail holders up to 60 A
Finger-safe Optima Class CC, UL supplemental and IEC 10x38mm DIN-
Rail/panel mount holders up to 30 A
Finger-safe Optima™ Class CC, UL supplemental and IEC 10x38mm
DIN-Rail/panel mount protection modules up to 30 A
•ꢀ
CSA C22.2 No. 14, File 257020
•ꢀ
Conforms with IEC 60947-3
Online resources
Visit Eaton.com/bussmannseries for:
•ꢀ
CAD drawings
•ꢀ
Instruction sheets
•ꢀ
UL information
IEC specifications
RD16-3-508
RD16-3-508 with 6-pole conversion kit
Catalog no.
RD16-3-508
RD25-3-508
RD40-3-508
RD63-3-508
RD80-3-508
Thermal current Ith at 40°C (A)
Rated insulation voltage Ui (V)
Rated impulse withstand voltage Uimp (kV)
16
800
8
25
800
8
40
800
8
63
800
8
80
800
8
Rated operation currents Ie (A)
Load duty category
Rated voltage
A/B 1
16/16
16/16
16/16
16/16
16/16
A/B 1
25/25
25/25
25/25
25/25
25/25
A/B 1
40/40
25/25
40/40
32/40
25/25
A/B 1
63/63
63/63
63/63
40/63
40/40
A/B 1
80/80
63/63
80/80
63/80
40/40
AC-22 A/ AC-22 B
AC-23A/ AC-23 B
AC-21 A/ AC-21 B
AC-22 A/ AC-22 B
AC-23A/ AC-23 B
500
690
Operational power in AC-23 (kW)
400 Vac without prebreak AC 1, 2
500 Vac without prebreak AC 1, 2
690 Vac without prebreak AC 1, 2
Overload capacity (Ue 415 Vac)
7. 5
7. 5
7. 5
11
11
15
18.5
15
18.5
30
30
30
37
37
37
Rated short-time withstand current 0.3 s. ICW (kA
2.5
6
2.5
6
2.5
6
3
9
3
9
RMS) 3
Rated short-time making capacity Icm (kA peak) 3
Fuse protected short-circuit withstand (kA RMS prospective)
Prospective short-circuit current (kA RMS) 3
Associated fuse rating (A) 3
50
16
50
25
50
40
50
63
50
80
Connection
Minimum Cu cable cross section (mm2)
Maximum Cu cable section (mm2)
Tightening torque min/max (N•m)
1.5
16
2/2.2
1.5
16
2/2.2
1.5
16
2/2.2
2.5
35
3.5/3.85
2.5
35
3.5/3.85
1 A/B: Category with index A = frequent operation; category with index B = infrequent operation.
2 The power value is given for information only; the current values vary from one manufacturer to another.
3 For a rated operating voltage, Ue = 400 Vac.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-79
Eaton.com/bussmannseries
11 — Disconnect switches
UL specifications
RD16-3-508
RD16-3-508 with 6-pole conversion kit
Catalog no.
UL standard
RD16-3-508
UL 508
RD25-3-508
UL 508
RD40-3-508
UL 508
RD63-3-508
UL 508
RD80-3-508
UL 508
Max ampacity
16 A
25 A
40 A
63 A
80 A
Handle operation
Front/Side
Front/Side
Front/Side
Front/Side
Front/Side
UL ratings
Max voltage (AC)
3-phase, 208
600 Vac
600 Vac
7. 5
7. 5
15
20
600 Vac
7. 5
7. 5
20
25
600 Vac
15
20
40
40
600 Vac
15
20
40
40
3
5
10
10
3-phase, 240
3-phase, 480
Max. Hp ratings
3-phase, 600
Electrical characteristics
SCCR with fuse (kA)
65
J
30
65
J
30
10/65
J
60/30
50/65
J
100/60
50/65
J
100/60
Fuse class
Max. fuse rating (A)
Recommended upstream
Terminals
Wire type
Integral
Integral
Integral
75°C Cu
14-10, 26.5 (3)
12, 26.5 (3)
14-4 , 26.5 (3)
14-12, 26.5 (3)
Integral
75°C Cu
14-10, 31.1 (3.5)
12, 31.1 (3.5)
14-1, 31.1 (3.5)
10-6, 31.1 (3.5)
Integral
75°C Cu
14-10, 31.1 (3.5)
12, 31.1 (3.5)
14-1, 31.1 (3.5)
10-6, 31.1 (3.5)
75°C Cu
14-10, 26.5 (3)
12, 26.5 (3)
14-4, 26.5 (3)
14-12, 26.5 (3)
75°C Cu
14-10, 26.5 (3)
12, 26.5 (3)
14-4, 26.5 (3)
14-12, 26.5 (3)
Solid single
Solid dual
Stranded single
Stranded dual
Wire range and torque - lb-in
(N•m)
Mechanical characteristics
Endurances/cycles
Physical characteristics
Dimensions
10,000
10,000
10,000
10,000
10,000
See drawings on product pages
Weight- lb (kg)
0.5 (0.2)
0.5 (0.2)
0.5 (0.2)
0.7 (0.32)
0.7 (0.32)
Environmental
Operating temperature
Flammability rating
Accessories
-20 to 70°C
UL 94-V0
-20 to 70°C
UL 94-V0
-20 to 70°C
UL 94-V0
-20 to 70°C
UL 94-V0
-20 to 70°C
UL 94-V0
Direct
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
SH4-150
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
SH4-150
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
SH4-150
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
SH4-150
SH4-200
SH4-320
SH3-200
SH3-320
SH3-400
SH-GUIDE1
SH-GUIDE2
DOOR-508
—
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
SH4-150
SH4-200
SH4-320
SH3-200
SH3-320
SH3-400
SH-GUIDE1
SH-GUIDE2
DOOR-508
—
Short selector/NEMA 1, 3R, 4,
4X, 12
Long selector/NEMA 1, 3R, 4,
4X, 12
Handles
Pistol handle/NEMA 1, 3R, 4,
4X, 12
Metallic hasp (HD) pistol handle/
NEMA 1, 3R, 4, 4X, 12
5.9"/150mm
Selector handle shafts - 5x5mm 7.9"/200mm
SH4-200
SH4-320
SH3-200
SH3-320
SH4-200
SH4-320
SH3-200
SH3-320
SH4-200
SH4-320
SH3-200
SH3-320
12.6"/320mm
7.9"/200mm
12.6"/320mm
15.75"/400mm
Pistol handle shafts - 5x5mm
SH3-400
SH3-400
SH3-400
Selector handle shaft guide
Pistol handle shaft guide
Door mount kit
SH-GUIDE1
SH-GUIDE2
DOOR-508
TSH1-1TB
TSH1-3TB
POLE-16
SH-GUIDE1
SH-GUIDE2
DOOR-508
TSH1-1TB
TSH1-3TB
POLE-25
SH-GUIDE1
SH-GUIDE2
DOOR-508
TSH1-1TB
TSH1-3TB
POLE-40
1-Pole
3-Pole (loadside and lineside)
Switched 4th pole/switch amps
TSH2-3TB
—
TSH2-3TB
—
Shrouds/switch amps
Auxiliary contacts
Ground module (conforms to IEC
60947-3)
Neutral module (conforms to IEC
60947-3)
NO + NC (1 ea.)
(2) NO
AC ratings
Volts
GND-16-40
NTRL-16-40
GND-16-40
NTRL-16-40
GND-16-40
NTRL-16-40
GND-63-80
NTRL-63-80
GND-63-80
NTRL-63-80
BAC01
BAC02
BAC01
BAC02
BAC01
BAC02
BAC01
BAC02
BAC01
BAC02
240 Vac
10
240 Vac
10
240 Vac
10
240 Vac
10
240 Vac
10
Amps
6-/8-pole conversion kit gangs two switches of same rating, 16-80 A
switch amps
KIT-6POLE
KIT-6POLE
KIT-6POLE
KIT-6POLE
KIT-6POLE
—Not available.
11-80
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 508 non-fused rotary disconnect switches —16, 25, 40, 63 and 80 A
For a complete assembly, select:
Switch
Max. Class
J fuse
Max horsepower rating, 3-Phase
SCCR @600V
(kA)
Conductor AWG size/
Amps
16
25
Poles
3
amps
208
3
220/240 440/480
600
10
20
type
Catalog no.
RD16-3-508
RD25-3-508
5
10
15
65
30
14-10 Sol, Dual 12
Sol, 14-4 Str, Dual
14-12 Str, 75°C Cu
7. 5
7. 5
10
65
50
65
50
65
60
30
100
60
100
60
40
63
80
7. 5
15
15
7. 5
20
20
40
40
25
40
40
RD40-3-508
RD63-3-508
RD80-3-508
14-10 Sol, Dual 12
Sol, 14-1 Str, Dual
10-6 Str, 75°C Cu
20
PLUS
Direct mount handle - mounts directly to switch, no shaft required
For switch cat. no.
Color
Test function
Padlockable
Catalog no.
DIR-01
All switches
Black
N
Y - On Switch
OR
External front or right side operated selector handles - shaft required
1
2
NEMA type
Color
Black
Red/yellow
Black
Handle length
Test function
Padlockable
Y
Catalog no.
H4X-01B (1)
H4X-01R (1)
H4X-02B (2)
H4X-02R (2)
Short
1, 3R, 4, 4X, 12
N
Long
Red/yellow
Or
External front operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Handle length
Test function
N
Padlockable
Y
Defeatable
Y
Catalog no.
H4X-03B
H4X-03R
1, 3R, 4, 4X, 12
—
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA type
Color
Black
Red/yellow
Handle length
Test function
Padlockable
Y
Defeatable
Y
Catalog no.
H4X-03BHD
H4X-03RHD
1, 3R, 4, 4X, 12
—
N
+
Shafts for selector handles
Length — in (mm)
5.9 (150)
7.9 (200)
Mounting depth (X) - in (mm)
3.50~7.60 (89~193)
3.50~9.50 (89~241)
3.50~14.9 (89~378)
Catalog no.
SH4-150 (1)
SH4-200 (1)
SH4-320 (1)
1
12.6 (320)
Shafts for pistol handles
Length — in (mm)
7.9 (200)
12.6 (320)
Mounting depth (X) - in (mm)
Catalog no.
SH3-200 (2)
SH3-320 (2)
SH3-400 (2)
2
3.30~7.40 (84~188)
3.30~9.30 (84~236)
3.30~14.7 (84~373)
15.7 (400)
+
+
Shaft guides for selector and pistol handles
Handle type
Catalog no.
SH-GUIDE1
Selector
Required for 12.6" (320mm) long shafts, optional for other lengths
Required for 15.7" (400mm) long shafts, optional for other lengths
Pistol
SH-GUIDE2
Door mount kit
For mounting switch on the right side of the enclosure or directly on the enclosure door using switch side operation shaft location. Kit
includes a shaft. Order switch and selector handle separately.
Switch
Catalog no.
All switches - kit includes shaft
DOOR-508
AND...
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-81
Eaton.com/bussmannseries
11 — Disconnect switches
Auxiliary contacts
No. of
contacts
1 Ea.
Continuous amp
rating
Contact type
NO + NC
Voltage (Vac) rating
Max number of units per switch Catalog no.
BAC01
10
240
2 (1 per side/4 contacts total)
BAC02
NO
2
AND...
Terminal shrouds - includes terminal shroud for both lineside and loadside
Switch
Poles
amps
Location on switch
Catalog no.
16-40
16-40
63-80
1 (for switched 4th pole)
TSH1-1TB
TSH1-3TB
TSH2-3TB
Lineside and loadside
3
AND...
Switched 4th pole - converts 3-pole switch to 4-pole switch
Switch amps
Catalog no.
POLE-16
16
25
40
POLE-25
POLE-40
AND...
Ground and Neutral Modules - provides unswitched ground or neutral pole - conforms to IEC 60947-3
Switch amps
Module Type
Catalog no.
GND-16-40
16-40
Ground
63-80
16-40
63-80
GND-63-80
NTRL-16-40
NTRL-63-80
Neutral
AND...
6-pole conversion kit - creates a 6-pole switch by ganging two 3-pole switches of equal rating
Switch amps
All switches
Catalog no.
KIT-6POLE*
* Kit ships with a direct handle. If external handle is needed order a selector handle and shaft for the UL 508 Rotary Disconnect
Switches.
Note: To create an 8-pole switch from 16 to 40 amp switches, use two 3-pole switches of equal ratings plus two switched 4th poles
(part # POLE-_).
Order switches separately
Auxiliary contact
configurations
Ground and neutral module, and
switched 4th pole configurations.
Dimensions — in (mm)
1.42
36
E
F
D
2
1.42
36
2.95
75
3.19
81
2.52
64
1.99
50.6
M
F
2.52
1
1
M
2
64
J
1
2
1
2
0.24
6
0.35 F1
8.8
F1 0.35
8.8
T
1.97
50
M5
0.35
8.8
F1
F1
0.35
8.8
0.23
T
6
1.96
50
M5
Direct handle operation
External front operation
External side operation
1. Position for 1 switched 4th pole (1 per device max.), or ground or neutral module (2 per device max.) or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 Auxiliary contacts, or 3 Auxiliary contacts + one ground or neutral module, or one switched 4th pole.
Overall dimensions
D max E min
Switch body
F1
Switch mounting
Switch
amps
Terminal
shroud AC
D min
E max
F
G
J
M
N
Connection T
0.59 (15)
16 to 40 1.18 (30) 9.25 (235) 3.94 (100) 14.64 (372) 4.33 (110)
63 to 80 1.18 (30) 9.25 (235) 3.93 (100) 14.64 (372) 4.33 (110)
1.77 (45) 0.59 (15) 2.67 (68)
2.06 (53) 0.69 (18) 2.99 (76)
0.59 (15)
1.18 (30) 2.95 (75)
0.69 (18) 1.38 (35) 3.35 (85)
0.69 (18)
11-82
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
Dimensions — in (mm)
F
F
J
J
3.50
89
3.07
78
F2
F2
1
1
1
1
E
1.42
36
X M
2.06
52.5
X M
2.06
52.5
2
2
2
2
0.24
6
1.69 1.36
0.35
8.8
0.35
8.8
0.35 F1
8.8
F1
0.35 F1
8.8
F1
0.29
7.5
0.29
7.5
T T
2.06
52.5
T T
2.06
52.5
34.7
43
Direct front operation for 6/8-pole disconnects
External front operation for 6/8-pole disconnects
1. Position for 1 switched 4th pole (1 per device max.) or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4th pole.
Overall dimensions
E max
Switch body
Switch mounting
Connection
Switch
amps
E min
F
F1
F2
G
J
M
N
T
X
16 to 40 4.13 (105) 14.64 (372) 3.83 (98)
0.59 (15)
1.77 (45)
2.06 (53)
2.67 (68)
2.99 (76)
1.92 (48.75) 1.18 (30) 2.95 (75)
0.59 (15)
0.69 (18)
0.29 (8)
0.34 (9)
63 to 80 4.13 (105) 14.65 (372) 4.13 (105) 0.69 (18)
2.06 (52.5)
1.38 (35) 3.35 (85)
External selector and pistol handles
Handle type
Door drilling layouts
Ø3.07
Ø78
1.57
40
0.11
3
4 Ø 0.27
4 Ø 7
Direction of
front operation
Direction of
right side operation
Selector
H4X-01_
1.42
36
I
I
Ø3.07
Ø78
Ø 1.22
Ø 31
Ø
Ø
0.88
22.5
0
0
With mounting nut
With 4 Mounting Screws
Selector
H4X-02_
1.45
37
1.57
40
4 Ø 0.27
4 Ø 7
H4X-03_ with 4 mounting screws
Pistol
H4X-03_
Ø 1.45in/37mm screw clip (from front)
Ø 1.22in/31mm screw (from rear)
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-83
Eaton.com/bussmannseries
11 — Disconnect switches
UL 98 and UL 508 enclosed disconnect switches
Enclosed fused and non-fused rotary disconnect switches from 16 to
1200 A in NEMA 1, 3R, 4, 4X, 12 enclosures.
Ratings
2011/65/EU
•ꢀ
Volts
•ꢀ 600 Vac
•ꢀ 250-600 Vdc*
•ꢀ
•ꢀ
Amps 16-1200 A
SCCR
NEMA 1, 3R, 4 and 12
•ꢀ UL 98 25-200 kA
•ꢀ UL 508 10-65 kA
* Some non-fused disconnect switches are not rated for DC applications.
Agency information
•ꢀ
UL 98 Listed, Guide WIAX, WIAX7, File E182262
•ꢀ
UL 508 Listed, Guide NLRV, NLRV, File E155129
•ꢀ
cULus Listed to Canadian Standard 22.2, No. 14
•ꢀ
cULus Listed to Canadian Standard 22.2, No. 4
•ꢀ
Conforms with IEC 60947-3
•ꢀ
RoHS compliant
•ꢀ
CE
NEMA 4X 304 stainless steel
Operating temperature
•ꢀ
-20ºC to 70ºC
4X plastic enclosure flammability ratings
•ꢀ
Polycarbonate UL 94-5V A-0
•ꢀ
Fiberglass UL 94-5V
Field installed accessories
•ꢀ
Auxiliary contacts
•ꢀ
Terminal shrouds
Switched 4th pole (UL 508 only)
•ꢀ
NEMA 4X polycarbonate or fiberglass
Online resources
Visit Eaton.com/bussmannseries for:
•ꢀ
CAD drawings
•ꢀ
Instruction sheets
•ꢀ
UL information
Features
•ꢀ
UL 98 Listed for general purpose, main disconnect, or branch
circuit protection up to 600 Vac/dc
•ꢀ
UL 508 Listed for motor disconnect applications up to 600 Vac
•ꢀ
Multiple field installed accessories enhance the enclosed
disconnect switches to fit the desired application
•ꢀ
Lockout/tagout: Up to three 1/4" shank padlocks can be installed
on external handles
11-84
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 98 enclosed fused disconnects — 30 to 800 A
3-pole UL 98 600 Vac
Catalog number system:
ER 4X
-
60
J
3
P
B
ER
Enclosed Rotary disconnect
NEMA 1, 3R, 4 and 12
NEMA 4X
304 stainless steel
NEMA 4X
NEMA rating
1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12
Amp rating
30-800A UL 98 fused switches
30, 60, 100, 200, 400, 600, 800
Fuse class
Available Bussmann series fuses
J = Class J, L = Class L
Number of poles
3 = 3-pole
Fuse class Catalog symbol/type
LPJ time-delay, current limiting
JKS fast-acting fuses
J
Handle type
DFJ high speed drive fuse
KRP-C time-delay, current limiting
KTU fast-acting
P = Pistol
Handle color
L
KLU time-delay
B = Black, R = Red
KRP-CL (225-600 A)
Catalog numbers
All catalog numbers provided with integral or installed lugs and a
black selector handle. Order Red/yellow handle by changing the
suffix “B” to “R.”
NEMA enclosure type and catalog no.
Switch amps
Fuse class
1
3R
4
4X plastic1
ER4P-30J3PB
ER4P-60J3PB
ER4P-100J3PB
ER4P-200J3PB
ER4P-400J3PB
ER4P-600J3PB
ER4P-800L3PB
4X 304 stainless
12
30
60
ER1-30J3PB
ER1-60J3PB
ER1-100J3PB
ER1-200J3PB
ER1-400J3PB
ER1-600J3PB
ER1-800L3PB
ER3R-30J3PB
ER3R-60J3PB
ER3R-100J3PB
ER3R-200J3PB
ER3R-400J3PB
ER3R-600J3PB
ER3R-800L3PB
ER4-30J3PB
ER4-60J3PB
ER4X-30J3PB
ER4X-60J3PB
ER4X-100J3PB
ER4X-200J3PB
ER4X-400J3PB
ER4X-600J3PB
ER4X-800L3PB
ER12-30J3PB
ER12-60J3PB
ER12-100J3PB
ER12-200J3PB
ER12-400J3PB
ER12-600J3PB
ER12-800L3PB
100
200
400
600
800
ER4-100J3PB
ER4-200J3PB
ER4-400J3PB
ER4-600J3PB
ER4-800L3PB
J
L
1 Enclosures ≤100 A are polycarbonate, flammability rating UL 94-5V A-V0, ≥200 A
are fiberglass, flammability rating UL 94-5V.
Switch ratings
For wire types, ranges and terminal torques, see table on page 11-55.
Voltage
Switch amps
Switch cat. no.
Fuse class
Poles
Vac
Vdc
SCCR @ Vac (kA)
Max. Hp @ 600 Vac
30
RDF30J-3
20
250
60
RDF60J-3
RDF100J-3
RDF200J-3
RDF400J-3
50
75
150
350
100
200
400
J
N/A
250
3
600
200
600
800
RDF600J-3
RDF800L-3
600
500
L
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-85
Eaton.com/bussmannseries
11 — Disconnect switches
UL 98 enclosed fused disconnects — 30 to 800 A
W
Enclosure weights and dimensions
Mounting centers h x w (in)
Catalog no.
family
Fuse
class
NEMA
enclosure
1, 3R, 4, 12
4X-SST
4X-plastic 1
1, 3R, 4, 12
4X-SST
4X-plastic 1
1, 3R, 4, 12
4X-SST
4X-plastic 1
1, 3R, 4, 12
4X-SST
4X-plastic 1
1, 3R, 4, 12
4X-SST
4X-plastic 1
1, 3R, 4, 12
4X-SST
Amps
H x W x D (in)
A
B
—
C
—
Weight (lbs)
MH H
A
8.3x8.3
—
—
10.3x8.3
—
—
10x10x6
15
8
ER_-30J
30
10.7x8.3
12x5.6
—
8.3x10.7
7.6x10
—
12x10x6
19
ER_-60J
60
12.7x8.3
14x7.6
—
8.3x10.7
9.6x12
—
MW
W
13x13x6
14x12x6
11
12.3x10.3
21
—
—
14.7x10.3
14x7.6
—
12.3x12.7
9.6x12
—
ER_-100J
ER_-200J
ER_-400J
ER_-600J
ER_-800L
100
200
400
600
800
13x13x6
12
J
22.3x18.3
24x20x8
27x21x10
48x36x12
51x37x14
48x36x12
51x37x14
48x36x12
51x37x14
55
—
—
24.7x18.3
25.75x14
—
22.3x20.7
—
H
MH
39
B
46.3x34.3
—
188
186
216
214
216
214
—
—
48.7x34.3
50x28.5
—
46.3x36.7
—
46.3x34.3
—
MW
W
—
48.7x34.3
50x28.5
—
46.3x36.7
—
4X-plastic 1
1, 3R, 4, 12
4X-SST
—
46.3x34.3
—
—
L
48.7x34.3
50x28.5
46.3x36.7
—
4X-plastic 1
—
1 Enclosures ≤100 A are polycarbonate, flammability rating UL 94-5V A-V0, ≥200 A
are fiberglass, flammability rating UL 94-5V.
H
MH
C
Available field-Installed accessories - order separately
Auxiliary contacts - for 30 to 800 amp switches
MW
Contact type No. of contacts Cont. amp rating
Vac
Max. units per switch Catalog no.
NO
4 (30 to 200 A)
8 (400 to 800 A)
BAC05
BAC06
1
10
600
NC
Terminal shrouds
For 200 to 800 amp switches - includes terminal shroud for lineside
or loadside
Switch amps
200
Poles Catalog no.
TSH8-3TB
400
3
TSH9-3TB
600-800
TSH10-3TB
11-86
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 98 enclosed non-fused disconnects —
30 to 1200 A
3-pole UL 98 600 Vac
Catalog number system:
ER 4X
-
60
N
3
P
B
NEMA 1, 3R, 4 and 12
NEMA 4X
304 stainless steel
NEMA 4X
ER
Enclosed Rotary disconnect
200-1200A UL 98 non-fused switches
NEMA rating
1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12
Amp rating
30, 60, 100, 200, 400, 600, 800, 1200
N = non-fused
Number of poles
3 = 3-pole
Handle type
NEMA 1, 3R, 4 and 12
NEMA 4X
304 stainless steel
NEMA 4X
P = Pistol
30-800A UL 98 non-fused switches
Handle color
B = Black, R = Red
Catalog numbers
All Catalog numbers provided with integral or installed lugs and a black
selector handle. Order Red/yellow handle by changing the suffix “B” to
“R.”
NEMA enclosure type and catalog no.
Amps
30
60
100
200
400
600
800
1200
1
3R
4
4X plastic 1
ER4P-30N3PB
ER4P-60N3PB
ER4P-100N3PB
ER4P-200N3PB
ER4P-400N3PB
ER4P-600N3PB
ER4P-800N3PB
N/ A
4X 304 stainless
ER4X-30N3PB
ER4X-60N3PB
ER4X-100N3PB
ER4X-200N3PB
ER4X-400N3PB
ER4X-600N3PB
ER4X-800N3PB
ER4X-1200N3PB
12
ER1-30N3PB
ER1-60N3PB
ER1-100N3PB
ER1-200N3PB
ER1-400N3PB
ER1-600N3PB
ER1-800N3PB
ER1-1200N3PB
ER3R-30N3PB
ER3R-60N3PB
ER3R-100N3PB
ER3R-200N3PB
ER3R-400N3PB
ER3R-600N3PB
ER3R-800N3PB
ER3R-1200N3PB
ER4-30N3PB
ER4-60N3PB
ER4-100N3PB
ER4-200N3PB
ER4-400N3PB
ER4-600N3PB
ER4-800N3PB
ER4-1200N3PB
ER12-30N3PB
ER12-60N3PB
ER12-100N3PB
ER12-200N3PB
ER12-400N3PB
ER12-600N3PB
ER12-800N3PB
ER12-1200N3PB
1 Enclosures ≤100 A are polycarbonate, flammability rating UL 94-5V A-V0, ≥200 A
are fiberglass, flammability rating UL 94-5V.
Switch ratings
For wire types, ranges and terminal torques, see table on page 11-72.
Amps Switch catalog no. Poles Vac SCCR (kA)
Max. Hp @ 600 Vac
30
60
RD30-3
RD60-3
25
100
50
100
200
400
600
800
1200
RD100-3
RD200-3
RD400-3
RD600-3
RD800-3
RD1200-3
25/100*
200
350
3
600
200
100
500
* 25 kA @ 600 Vac, 100 kA @ 480 Vac.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-87
Eaton.com/bussmannseries
11 — Disconnect switches
UL 98 enclosed non-fused disconnects —
30 to 1200 A
W
Enclosure weights and dimensions
MH H
Mounting centers h x w (in)
A
Catalog
NEMA
no. family Amps
enclosure
H x W x D (in)
10x8x6
A
B
—
C
—
Weight (lbs)
1, 3R, 4, 12
4X-SST
4X-plastic (1)
1, 3R, 4, 12
4X-SST
8.3x6.3
11
11
5
ER_-30
30
60
—
—
8.3x6.3
10.7x6.3
10x3.6
—
8.3x8.7
5.6x8
—
MW
W
9x9x6
12
10x8x6
ER_-60
—
—
10.3x8.3
10.7x6.3
10x3.6
—
8.3x8.7
5.6x8
—
12
5
12
4X-plastic (1)
1, 3R, 4, 12
4X-SST
4X-plastic (1)
1, 3R, 4, 12
4X-SST
4X-plastic (1)
1, 3R, 4, 12
4X-SST
4X-plastic (1)
1, 3R, 4, 12
4X-SST
4X-plastic (1)
1, 3R, 4, 12
4X-SST
4X-plastic (1)
1, 3R, 4, 12
4X-SST
9x9x6
12x10x6
13x13x6
20x16x8
20x17x12
36x30x8
37x32x14
48x36x12
51x37x 14
48x36x12
51x37x 14
ER_-100
ER_-200
ER_-400
ER_-600
100
200
400
600
—
—
12.7x8.3
14x7.6
—
20.7x14.3 18.3x16.7
21.5x10.1
8.3x10.7
9.6x12
—
12
8
39
39
H
MH
B
18.3x14.3
—
—
31
MW
W
34.3x28.3
—
—
122
122
103
209
209
187
211
211
189
268
268
—
—
36.7x28.3 34.3x30.7
38x28.9
—
48.7x34.3 46.3x36.7
50x28.5
—
48.7x34.3 46.3x36.7
50x28.5
—
—
—
46.3x34.3
—
H
MH
C
—
46.3x34.3
—
—
—
ER_-800
800
—
—
—
MW
58.3x34.3
—
60x36x16
60x36x16
ER_-1200
1200
60.7x34.3 58.3x36.7
1 Enclosures ≤100 A are polycarbonate, flammability rating UL 94-5V A-V0, ≥200 A are fiberglass, flammability rating UL 94-5V.
Available field-installed accessories - order separately
Auxiliary contacts for 30 to 1200 amp switches.
Switch amps Contact type No. of contacts Cont. amp rating
Vac
Max. units per switch Catalog no.
NO + NC
NO
NO + NC
NO + NC
NO + NC
NO + NC
1 of each
2
1 of each
1 of each
1 of each
1 of each
BAC01*
BAC02*
BAC03**
BAC04**
BAC11**
BAC12**
30-100
10
10.1
1
240
4
125-250
125
200-1200
2
* Two (2) Units per switch max.
**For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.
Terminal shrouds for 200 to 800 amp switches
Switch amps
Poles
Location on switch
Lineside and loadside
Lineside
Catalog no.
TSH3-3TB
TSH4-3T
TSH4-3B
TSH5-3T
TSH5-3B
TSH6-3TB
TSH7-3TB
30-100
200
400
Loadside
Lineside
Loadside
3
600
800-1200
Lineside or loadside
11-88
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
Disconnect switches — 11
UL 508 enclosed non-fused disconnect — 16 to 80 A
3-/6-pole UL 508 600 Vac
Catalog number system:
ER 4X
-
63
N
6
P
B
ER
Enclosed Rotary disconnect
NEMA rating
NEMA 1, 3R, 4 and 12
NEMA 4X
NEMA 4X
304 stainless steel
1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12
Amp rating
16-80 A UL 508 non-fused switches
16, 25, 40, 63, 80
N = non-fused
Number of poles
3 = 3-pole, 6 = 6-pole
Handle type
S = Selector*, P = Pistol**
Handle color
B = Black, R = Red
* 6-Pole switches only, selector handle does not interlock the enclosure door.
**3-pole switches only.
Catalog numbers
All catalog numbers provided with a black selector handle. Order red/
yellow handle by changing the suffix “B” to “R.”
NEMA enclosure and catalog no.
Amps
Poles
1
3R
4
4X plastic 1
ER4P-16N3PB
ER4P-16N6SB
ER4P-25N3PB
ER4P-25N6SB
ER4P-40N3PB
ER4P-40N6SB
ER4P-63N3PB
ER4P-63N6SB
ER4P-80N3PB
ER4P-80N6SB
4X 304 stainless
ER4X-16N3PB
ER4X-16N6SB
ER4X-25N3PB
ER4X-25N6SB
ER4X-40N3PB
ER4X-40N6SB
ER4X-63N3PB
ER4X-63N6SB
ER4X-80N3PB
ER4X-80N6SB
12
3
6
3
6
3
6
3
6
3
6
ER1-16N3PB
ER1-16N6SB
ER1-25N3PB
ER1-25N6SB
ER1-40N3PB
ER1-40N6SB
ER1-63N3PB
ER1-63N6SB
ER1-80N3PB
ER1-80N6SB
ER3R-16N3PB
ER3R-16N6SB
ER3R-25N3PB
ER3R-25N6SB
ER3R-40N3PB
ER3R-40N6SB
ER3R-63N3PB
ER3R-63N6SB
ER3R-80N3PB
ER3R-80N6SB
ER4-16N3PB
ER4-16N6SB
ER4-25N3PB
ER4-25N6SB
ER4-40N3PB
ER4-40N6SB
ER4-63N3PB
ER4-63N6SB
ER4-80N3PB
ER4-80N6SB
ER12-16N3PB
ER12-16N6SB
ER12-25N3PB
ER12-25N6SB
ER12-40N3PB
ER12-40N6SB
ER12-63N3PB
ER12-63N6SB
ER12-80N3PB
ER12-80N6SB
16
25
40
63
80
1 Polycarbonate enclosure flammability rating UL 94-5V A-V0.
Switch ratings
For wire types, ranges and terminal torques, see table on page 11-80.
Amps
16
25
40
63
Switch catalog no.
RD16-3-508
Vac
SCCR with max upstream Class J fuse
Max. Hp @ 600 V
10
20
25
40
40
65 kA /30 A
RD25-3-508
RD40-3-508
RD63-3-508
RD80-3-508
600
65 kA /30 A — 10 kA / 60 A
65 kA /60 A — 50 kA / 100 A
50 kA / 100 A
80
Note: Voltage, SCCR and horsepower ratings are the same for 3- and 6-pole switches.
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
11-89
Eaton.com/bussmannseries
11 — Disconnect switches
UL 508 enclosed non-fused disconnect — 16 to 80 A
W
Enclosure weights and dimensions
Mounting centers h x w (in)
NEMA
Switch
amps
MH H
enclosure
Poles
H x W x D (in)
8x6x6
A
6.3x4.3
8.3x6.3
—
—
—
B
C
Weight (lbs)
A
3
6
3
6
3
—
—
8
11
8
11
4
1, 3R, 4, 12
4X-304 SST
10x8x6
8x6x6
10x8x6
—
—
16-80
8.7x4.3
10.7x6.3
8x3.6
10x3.6
12x5.6
6.3x6.7
8.3x8.7
3.6x8
5.6x8
7.6x10
MW
W
16-63
80
16-8 A
7.4x8.7x5.8
9.4x8.7x5.9
11.4x10.7x6.3
4X-plastic 1
—
—
5
6
6
1 Polycarbonate.
H
MH
Available field-installed accessories - order separately
Auxiliary contacts
B
Cont.
MW
W
No. of
amp
Contact type contacts rating
Vac
Max. units per switch
Catalog no.
BAC01
BAC02
NO + NC
NO
1 Ea.
2
10
240
2 (1 per side, 4 contacts total)
Auxiliary contact
configurations
H
MH
C
Terminal shrouds
Includes terminal shroud for both lineside and loadside.
MW
Switch amps
16-40
Poles
Location on switch
Lineside and loadside
Catalog no.
TSH1-3TB
TSH2-3TB
3
63-80
Switched 4th pole
Converts 3-pole switch to 4-pole switch.
Switch amps
Catalog no.
POLE-16
16
25
40
POLE-25
POLE-40
11-90
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018
Eaton.com/bussmannseries
相关型号: