BB-485OPDR [ETC]
REPEATER RS422/485 ISOLATED;![BB-485OPDR](http://pdffile.icpdf.com/pdf2/p00319/img/icpdf/BB-485OPDR_1916149_icpdf.jpg)
型号: | BB-485OPDR |
厂家: | ![]() |
描述: | REPEATER RS422/485 ISOLATED 中继器 |
文件: | 总2页 (文件大小:1027K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Biasing
Recommended Accessories
Bias is provided by 4.7kΩ pull-up/down resistors on
the Data-In lines. This value is adequate for most
applications without termination. If another value is
required, space is provided on the PC for through-hole
resistor placement (R12, R21, R14, and R23).
QUICK START
GUIDE
Model MDR-20-24
Power Supply
For more information on Biasing, see B+B SmartWorx
Application Notes at:
www.bb-elec.com/Learning-Center.aspx
UL Installation Information
Model HESP4DR
Data Line Surge Suppressor
Underwriters Laboratories Conditions of Acceptability –
when installed in the end-use equipment, consideration
should be given to the following:
1. The wiring terminals are suitable for factory wiring
only.
2. This device is to be mounted in a suitable enclosure
in the end-product.
3. This device is suitable for operation at a maximum
surrounding air temperature as described in the
documentation.
4. These devices are intended for use in a Pollution
Degree 2 Environment.
485OPDR
• Input Voltage: 10 – 30 VDC
• Input Power: 0.7 Watts
Optically Isolated RS-422/485 Repeater
• Wire Range: 12 – 24 AWG
• Tightening Torque: 4 kgf-cm
• Temperature rating of field installed conductors is
105 °C minimum, sized for 60 °C ampacity.
• Use copper wire only
Before you begin, be
sure you have the following:
• Maximum surrounding ambient air temperature 80 °C
+ 485OPDR Repeater
+ 10-30VDC, 0.7W Power Supply
+ RS-422/RS-485 Cable
1-888-948-2248 | Europe: +353 91 792444
advantech-bb.com
707 Dayton Road | PO Box 1040 | Ottawa, IL 61350
Phone: 815-433-5100 | Fax: 815-433-5109
Document Number – 710-10765-00_485OPDR_4316qsg
www.advantech-bb.com | E-mail: support@advantech-bb.com
Fast and easy on the web: www.advantech-bb.com
SW-7: TX Enable
ON
SW-8: RX Enable
ON
Product Overview
RS-485 2-Wire Half Duplex
RS-485 4-Wire Full Duplex
RS-422 Full Duplex
External Power Supply 10 to 30 VDC
Connections: Ground/V(-) = M V (+) = J
ON
OFF
OFF
OFF
SWITCH
K Baud (ms)
1.2
1
2
3
4
5
6
Timeout
9.02
4.73
2.20
1.1
Terminal Block
Connectors
G – M
Terminal Block
Connectors
A – F
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
2.4
4.8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
9.6
OFF
OFF
OFF
OFF
OFF
OFF
19.2
OFF
OFF
OFF
OFF
OFF
0.62
0.29
0.17
0.15
0.11
38.4
OFF
OFF
ON
DIP
Switches
57.6
OFF
OFF
ON
76.8
ON
115.2
ON
ON
RS-422 Full
Duplex
OFF
NOTE: Terminal block and DIP switch
settings are shown on the product.
All connections for power and data are made
through screw terminal block connections.
+
Wiring Examples
2
ISOLATED
NON-ISOLATED
Jump L to K and H to G and power the 485OPDR.
Set dip switches to RS-422 or RS-485, depending
upon what you are using to connect to the PC. Set the
baud rate to 9600.
SW-7: TX Enable
SW-8: RX Enable
RS-485 4-Wire Full Duplex
RS-422 Full Duplex
ON
OFF
OFF
A
B
C
D
E
F
G
H
J
K
L
M
OFF
SWITCH
K Baud (ms)
9.6
1
2
3
4
5
6
Timeout
1.1
DIP Switches
Loopback Test
1
3
OFF OFF
ON
OFF OFF OFF
Two sets of DIP switches must be set, one for each side.
Setting the baud rate to 9600 will generally allow you to
communicate with higher baud rates.
You can perform a loopback test by connecting either an
RS-232 to RS-422/485 converter or a USB to RS-422/485
converter to the 485OPDR.
Using HyperTerminal or a similar program, connect to
the appropriate COM port. Remember to set the baud
rate to 9600. Turn off HyperTerminal local echo. Start
typing. If you can see the data you are typing, the
loopback is successful.
For more information, visit www.advantech-bb.com