2223-9024 [ETC]
RELAIS TERMINAL 1NO+1NC 24VD ; RELAIS终端1NO + 1NC 24VD\n型号: | 2223-9024 |
厂家: | ETC |
描述: | RELAIS TERMINAL 1NO+1NC 24VD
|
文件: | 总3页 (文件大小:59K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
22 Series - Modular Monostable Relays 20 A
22.21
22.22
- One module (17.5mm) wide
- Test button
- Identification label
- AC and DC coils
- 35 mm rail (EN 50022) mount
- Single phase switch 1 NO
- 35 mm rail (EN 50022)
- Double phase switch 2 NO
- 35 mm rail (EN 50022)
A1
A2
1
3
A1
A2
1
2
4
2
58.4
43.5
26.5
58.4
43.5
26.5
17.5
17.5
Contact specifications
Contact configuration
1 NO
20/30
2 NO
Rated current/Max. peak current
Rated voltage/Max. switching voltage
Rated load in AC1
A
V AC
VA
20/30
250/400
5,000
250/400
5,000
Rated load in AC15 (230 VAC)
Single phase motor rating (230 VAC)
Breaking capacity: 30/110/220 V
VA
1,000
1,000
kW/HP
A
—
—
20/0.3/0.12
1,000 (10/10)
AgNi
20/0.3/0.12
1,000 (10/10)
AgNi
Minimum switching load
Standard contact material
Coil specifications
Nominal voltage
mW(V/mA)
V AC (50/60Hz)
V DC
8 - 12 - 24 - 48 - 110 - 120 - 230 - 240
12 - 24 - 48 - 110 12 - 24 - 48 - 110
2.3/1.25 2.3/1.25
Rated power AC/DC
Operating range
VA (50Hz)/W
AC (50Hz)/W
DC
(0.85…1.1)UN
(0.9…1.1)UN
(0.85…1.1)UN
(0.9…1.1)UN
Technical data
3
3
Mechanical life
cycles
500 · 10
500 · 10
3
3
Electrical life at rated load in AC1
Maximum impulse duration
cycles
50 · 10
50 · 10
continuous
4,000
continuous
4,000
Surge test (1.2/50µs) between coil and contacts
Ambient temperature range
V
°C
–40…+40
IP 20
–40…+40
IP 20
Protection category
Approvals: (according to type)
136
22 Series - Modular Monostable Relays 20 A
22.23
22.24
- One module (17.5mm) wide
- Test button
- Identification label
- AC and DC coils
- 35 mm rail (EN 50022) mount
- Double phase switch
1 NO + 1 NC
- 35 mm rail (EN 50022)
- Double phase switch 2 NC
- 35 mm rail (EN 50022)
A1
A2
1
3
A1
A2
1
3
2
4
2
4
58.4
43.5
26.5
58.4
43.5
26.5
17.5
17.5
Contact specifications
Contact configuration
1 NO + 1 NC
20/30
2 NC
Rated current/Max. peak current
Rated voltage/Max. switching voltage
Rated load in AC1
A
V AC
VA
20/30
250/400
5,000
250/400
5,000
Rated load in AC15 (230 VAC)
Single phase motor rating (230 VAC)
Breaking capacity: 30/110/220 V
VA
1,000
1,000
kW/HP
A
—
—
20/0.3/0.12
1,000 (10/10)
AgNi
20/0.3/0.12
1,000 (10/10)
AgNi
Minimum switching load
Standard contact material
Coil specifications
Nominal voltage
mW(V/mA)
V AC (50/60Hz)
V DC
8 - 12 - 24 - 48 - 110 - 120 - 230 - 240
12 - 24 - 48 - 110 12 - 24 - 48 - 110
2.3/1.25 2.3/1.25
Rated power AC/DC
Operating range
VA (50Hz)/W
AC (50Hz)/W
DC
(0.85…1.1)UN
(0.9…1.1)UN
(0.85…1.1)UN
(0.9…1.1)UN
Technical data
3
3
Mechanical life
cycles
500 · 10
500 · 10
3
3
Electrical life at rated load in AC1
Maximum impulse duration
cycles
50 · 10
50 · 10
continuous
4,000
continuous
4,000
Surge test (1.2/50µs) between coil and contacts
Ambient temperature range
V
°C
–40…+40
IP 20
–40…+40
IP 20
Protection category
Approvals: (according to type)
137
22 Series - Modular Monostable Relays 20 A
ORDERING INFORMATION
Example: a 22 series 35 mm rail (EN 50022) mount relay with 1 NO (SPST-NO) - 20 A contacts, with coil rated at 24 V DC, contact material AgSnO2.
2 2 2 1 9 0 2 4 4 0 0 0
.
.
.
.
Series
Contact material
0 = AgNi standard
4 = AgSnO2
Type
2 = 35 mm rail (EN 50022) mount
Coil voltage
see coil specifications
No. of poles
1 = 1 NO (SPST-NO)
2 = 2 NO (DPST-NO)
3 = 1 NO (SPST-NO) +1 NC (SPST-NC)
4 = 2 NC (DPST-NC)
Coil version
8 = AC (50/60 Hz)
9 = DC
TECHNICAL DATA
CONTACT SPECIFICATIONS
NOMINAL RATE LAMPS
-
incandescence (230V)
W
1,000
360
- compensated fluorescent (230V) W
INSULATION
DIELECTRIC STRENGTH
- between supply and contacts V AC 3,500
- between open contacts V AC 2,000
- between adjacent contacts V AC 2,000
SURGE TEST (1.2/50µs)
- between supply and contacts
V
4,000
OTHER DATA
22.21
22.22, 22.23, 22.24
POWER LOST IN THE ENVIRONMENT
- without contact current
W
W
1.2
3.2
1.2
- with rated current
5.2
COIL CLAMPS
CONTACT CLAMPS
solid cable
1x6 / 2x6
1x10 / 2x10
0.8
MAX WIRE SIZE
solid cable
flexible cable
1x2.5 / 2x2.5
1x14 / 2x14
flexible cable
1x6 / 2x4
2
mm 1x4 / 2x2.5
AWG 1x12 / 2x14
Nm 0.8
1x10 / 2x12
TORQUE
If the coil is operated for a prolonged period of time, adaquate ventilation of the relays must be provided, for example leaving a gap of about 9mm
between pairs of relays.
COIL SPECIFICATIONS
AC VERSION DATA
DC VERSION DATA
Nominal
voltage
Coil
code
Operating range
Resistance Absorption
Nominal
voltage
Coil
code
Operating range
Resistance Absorption
I at UN (50Hz)
I at UN
UN
V
8
12
24
Umin
V
6.8
10.2
20.4
40.8
93.5
102
195.5
204
Umax
V
8.8
13.2
26.4
52.8
R
Ω
UN
V
12
24
48
110
Umin
V
10.8
21.6
43.2
99
Umax
V
13.2
26.4
52.8
121
R
Ω
mA
275
mA
104.3
52.2
25.9
11.3
8.008
8.012
8.024
8.048
8.110
8.120
8.230
8.240
6.5
13.5
42
185
980
1,400
4,250
4,400
9.012
9.024
9.048
9.110
115
460
1,850
9,700
185
95
48
21
18
10
48
110
120
230
240
121
132
253
264
9.5
138
相关型号: