DOP-103WQ [DELTA]

High Color ‧Widescreen‧ User-Friendly HMI Products Delta Electronics Inc,;
DOP-103WQ
型号: DOP-103WQ
厂家: DELTA ELECTRONICS, INC.    DELTA ELECTRONICS, INC.
描述:

High Color ‧Widescreen‧ User-Friendly HMI Products Delta Electronics Inc,

文件: 总2页 (文件大小:3588K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DOP-107WV / DOP-110WS COM2 Port  
DOP-107WV (Rear view)  
MODE1  
MODE2  
MODE3  
COM2  
COM Port  
Pin  
COM2  
COM3  
COM2  
COM3  
COM3  
RS-232  
RS-485  
RS-485  
D+  
RS-485  
RS-232  
RS-422  
TXD+  
1
2
3
4
5
6
7
8
9
RXD  
TXD  
RXD  
TXD  
High Color Widescreen‧  
User-Friendly HMI Products  
Delta Electronics Inc,  
DOP-103WQ  
DOP-107WV  
DOP-110WS  
D+  
D-  
D+  
D-  
RXD+  
TXD-  
GND  
GND  
GND  
No.18, Xinglong Rd., Taoyuan City  
33068, Taiwan  
D-  
RTS  
CTS  
RTS  
CTS  
Instruction Sheet  
RXD-  
Note 1: Blank means connection is not required.  
(1) Preface  
Thank you for purchasing DOP-107WV. This instruction sheet provides information about DOP-107WV.  
Before using the product, please read through this manual carefully in order to ensure the correct use of  
the product. In addition, please place this manual safely for quick reference whenever is needed. Please  
follow the rules below if you have not finished reading this manual yet.  
(3) Part names  
Power Input  
A
B
COM2/ COM3  
DOP-103WQ (Front view)  
(24AWG wire min.)  
C
E
COM1  
D
F
Network Port (LAN)  
USB Host  
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids,  
indoor use only.  
USB Slave  
Ensure that all wiring instructions and recommendations are followed.  
Ensure that HMI is correctly connected to the ground. The grounding method must comply with  
the national electrical standard (Please refer to NFPA 70: National Electrical Code, 2005 Ed.  
Do not modify the wiring or disassemble HMI interface when HMI is connected to the power.  
Do not touch the power supply during operation. Otherwise, it may cause electric shock.  
When HMI displays low power notification and requires battery changes, please contact local  
distributors or DELTA customer service center for the replacement. Do not change batteries by  
yourself.  
DOP-110WS (Front view)  
DOP-100 series can be used for industrial automation equipment. Please read through this  
manual carefully and install the product according to the instructions in order to avoid danger.  
Cleaning method: Please use dry cloth to clean the product.  
The product should be used at an altitude below 2000 m.  
If the equipment is used in a manner not specified by the manufacturer, the protection provided by  
the equipment may be impaired.  
For repairing and maintenance, please contact DELTA Electronics, Inc. Address: No.18, Xinglong  
Rd., Taoyuan City, Taiwan. TEL: +886-3-3626301.  
A
Touch ScreenDisplay  
If you have any enquiry during operation, please contact our local distributors or Delta sales  
representatives. The content of this instruction sheet may be revised without prior notice. Please consult  
our distributors or download the latest version at http://www.delta.com.tw/ia.  
DOP-103WQ (Rear view)  
A
Touch ScreenDisplay  
(2) Communication Port Pin Assignment  
DOP-103WQ COM Port  
DOP-110WS (Rear view)  
MODE1  
MODE2  
COM1 COM2  
MODE3  
COM1  
COM Port  
Pin  
COM1  
COM2  
COM2  
RS-422  
TXD+  
RS-232  
RS-485 RS-485 RS-485  
D+  
RS-232  
1
2
3
4
5
6
7
8
9
RXD  
TXD  
RXD  
TXD  
D+  
D-  
D+  
D-  
RXD+  
TXD-  
GND  
GND  
GND  
D-  
C
A
C
Power Input (24AWG wire min.)  
USB Slave  
B
D
COM1  
USB Host  
RTS  
CTS  
RTS  
CTS  
RXD-  
E
Network PortLAN)  
DOP-107WV / DOP-110WS COM1 Port  
DOP-107WV (Front view)  
MODE1  
COM Port  
Pin  
Power Input  
A
B
COM2/ COM3  
(24AWG wire min.)  
RS-232  
C
E
G
COM1  
D
F
Network Port (LAN)  
USB Host  
1
2
3
4
5
6
7
8
9
RXD  
TXD  
USB Slave  
SD Card  
GND  
RTS  
CTS  
A
Touch ScreenDisplay  
Model  
Flash ROM  
RAM  
DOP-103WQ  
DOP-107WV  
256 Mbytes  
512 Mbytes  
DOP-110WS  
Installation Method:  
(4) Dimensions for Installation  
Step 1:  
Step 2:  
DOP-103WQ  
Put the waterproof gasket into HMI and then  
insert the HMI into the panel cutout.  
Place the fasteners into slots and tighten the  
screws till reaching the panel cutouts.  
4-wire resistive touch screen  
> 10,000,000 operated  
Touch Screen  
Buzzer  
Multi-Tone Frequency (2 K ~ 4 K Hz)80 dB  
(Note 2)  
Ethernet Interface  
10/100 Mbps Auto sensing (with built-in isolated power circuit  
)
1 USB Slave Ver 2.0  
1 USB Host Ver 2.0  
USB  
SD  
N/A  
SD * 1  
RS-232 (supports flow control) (Note 2)  
RS-232 (supports flow control) / RS-485(Note 2)  
RS-422 / RS-485(Note 2)  
RS-232 (supports flow  
COM1  
)
control) / RS-485(Note 2)  
)
Serial  
Communication  
Port  
COM2 RS-422 / RS-485(Note 2)  
)
COM3  
N/A  
)
Step 3:  
Step 4:  
Function Keys  
Perpetual Calendar  
Cooling Method  
N/A  
Tighten the screws with torque less than 0.5N-M / For heat dissipation, please keep a minimum  
0.7N-M to avoid damage to the plastic case.  
DOP-107/DOP-110 Torque: 6.17 lb-inch (0.7N-M)  
clearance of 60 mm on the rear of the HMI.  
Built-in  
Natural cooling  
Operation Temperature is 0oC to 50oC and Storage Temperature is -20oC to +60oC  
DOP-107WV  
DOP-103 Torque: 4.41 lb-inch0.5N-M)  
CE / UL (Please use shielding Ethernet cable and the magnetic ring with filter of  
300 ohm/100 MHz)  
Safety Approval  
Waterproof Level of  
Panel Display  
IP65(Not be evaluated by UL)/NEMA4/ Type 4X indoor use only  
+24 VDC (-15% ~ +15%) (with built-in isolated power supply unit)  
Supplied by Class 2 or SELV circuit (isolated from MAINS by double insulation)  
Operation Voltage (Note2)  
Voltage Endurance  
500 VAC for 1 minute (between charging (DC24V terminal) and FG terminals)  
Power Consumption (Note  
5.8W (Max) (Note 3)  
8.4W (Max) (Note 3)  
11W (Max) (Note 3)  
2)  
Backup Battery  
3V lithium battery CR2032 × 1  
About 3 years or more at 25oC but subjects to the temperature and the conditions  
during usage.  
Backup Battery Life  
0oC ~ 50oC  
Operation Temperature  
Storage Temperature  
Operating Environment  
-20oC ~ +60oC  
10% ~ 90% RH [0 ~ 40oC], 10% ~ 55% RH [41 ~ 50oC]; Pollution degree: 2  
Recommended wiring is as follows:  
Vibration Resistance Conforms to IEC61131-2; Continuous: 5 Hz ~ 8.3 Hz 3.5 mm, 8.3 Hz ~ 150 Hz 1 G  
Type  
Solid  
Wire Gauge (AWG)  
24 ~ 12  
Stripped length  
7 ~ 8 mm  
Torque  
Shock Resistance  
Conforms to IEC60068-2-27: 11 ms, 15 G Peak , X, Y, Z direction for 6 times  
5 kg-cm (4.3 lb-in)  
5 kg-cm (4.3 lb-in)  
Stranded  
24 ~ 12  
7 ~ 8 mm  
Dimension  
(W) x (H) x (D) mm  
137 x 103 x 37.1  
196 x 136 x 39  
270 x 180.9 x 47.25  
Operation Temperature is 0oC to 50oC and Storage Temperature is -20oC to +60oC  
DOP-110WS  
Dimension for  
Installation  
(W) x (H) mm  
Be sure to perform wiring by referring to the following figure (power supply connector), wiring must  
be rated 75min.  
118.8 x 92.8  
Approx.280g  
186.8 x 126.8  
Approx. 560 g  
255 x 170  
Weight  
Approx. 1.1 Kgs  
Note:  
1. The half-life of backlight is defined as original luminance being reduced by 50% when the maximum  
driving current is supplied to HMI. The life of LED backlight shown here is an estimated value under 25oC  
normal temperature and humidity conditions.  
2. The withstand voltage of the isolated power circuit is 1500 V peak for 1 minute.  
3. Power consumption of HMI is the power consumed when not connecting to any peripheral devices. To  
ensure normal operation of HMI, the recommended power supply is: power consumption x 1.5 ~ 2.  
4. Isolated power supply is recommended.  
5. DOPSoft, the program editor for DOP-100 series products and user manuals can be downloaded at  
our website. In addition, the content of this instruction sheet may be revised without prior notice.  
Please consult our distributors or download the latest version at http://www.delta.com.tw/ia.  
6. DOP-100 series can be used for industrial automation equipment. Please read through this manual  
carefully and install the product according to the instructions to avoid danger.  
Operation Temperature is 0oC to 50oC and Storage Temperature is -20oC to +60oC  
(6) Specifications  
Model  
DOP-103WQ  
DOP-107WV  
DOP-110WS  
(5) Installation and Wiring  
4.3" TFT LCD  
7" TFT LCD  
(65535 colors)  
10.1" TFT LCD  
(65535 colors)  
Display Type  
Installation Notes:  
65535 colors)  
Improper installation will result in malfunction and greatly reduce the life of the HMI. Be sure to  
follow the guidelines in this quick start when installing the HMI.  
In order to ensure the HMI being well ventilated, make sure that the ventilation holes are not  
obstructed and provide sufficient clearance for the HMI.  
To protect the panel, be sure to install a waterproof gasket into HMI.  
For use on a flat surface of a Type 4X "Indoor Use Only" enclosure or equivalent. If Enclosure with  
lower type rating will cause de-rating.  
Resolution  
Backlight  
480 x 272 pixels  
800 x 480 pixels  
1024 x 600 pixels  
LCD  
Module  
LED Back Light (less than LED Back Light (less than LED Back Light (less than  
10,000 hours half-life at  
20,000 hours half-life at 30,000 hours half-life at 25  
25oC) (Note 1)  
25oC) (Note 1)  
oC) (Note 1)  
Display Size  
Brightness  
95.04 x 53.856 mm  
400 cd/m² (Typ.)  
154.08 x 85.92 mm  
225.52 x 128.10 mm  
450 cd/m² (Typ.)  
450 cd/m² (Typ.)  
The allowable thickness of the panel for mounting should be less than 5 mm.  
CPU  
ARM Cortex-A8 (800MHz)  

相关型号:

DOP-107WV

High Color ‧Widescreen‧ User-Friendly HMI Products Delta Electronics Inc,
DELTA

DOP-110WS

High Color ‧Widescreen‧ User-Friendly HMI Products Delta Electronics Inc,
DELTA

DOS06-05T

Non-isolated Point of load DC/DC converters
RSG

DOS06-05T

Non-isolated Point of load DC/DC converters
P-DUKE

DOS06-05T-P

Non-isolated Point of load DC/DC converters
RSG

DOS06-05T-P

Non-isolated Point of load DC/DC converters
P-DUKE

DOS06-12T

Non-isolated Point of load DC/DC converters
P-DUKE

DOS06-12T

Non-isolated Point of load DC/DC converters
RSG

DOS06-12T-P

Non-isolated Point of load DC/DC converters
P-DUKE

DOS06-12T-P

Non-isolated Point of load DC/DC converters
RSG

DOS10-05T

Non-isolated Point of load DC/DC converters
P-DUKE

DOS10-05T

Non-isolated Point of load DC/DC converters
RSG