DOP-107WV [DELTA]
High Color â§Widescreen⧠User-Friendly HMI Products Delta Electronics Inc,;型号: | DOP-107WV |
厂家: | DELTA ELECTRONICS, INC. |
描述: | High Color â§Widescreen⧠User-Friendly HMI Products Delta Electronics Inc, |
文件: | 总2页 (文件大小:3588K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DOP-107WV / DOP-110WS COM2 Port
DOP-107WV (Rear view)
MODE1
MODE2
MODE3
COM2
COM Port
Pin
COM2
COM3
COM2
COM3
COM3
RS-232
RS-485
RS-485
D+
RS-485
RS-232
RS-422
TXD+
1
2
3
4
5
6
7
8
9
RXD
TXD
RXD
TXD
High Color ‧Widescreen‧
User-Friendly HMI Products
Delta Electronics Inc,
DOP-103WQ
DOP-107WV
DOP-110WS
D+
D-
D+
D-
RXD+
TXD-
GND
GND
GND
No.18, Xinglong Rd., Taoyuan City
33068, Taiwan
D-
RTS
CTS
RTS
CTS
Instruction Sheet
RXD-
Note 1: Blank means connection is not required.
(1) Preface
Thank you for purchasing DOP-107WV. This instruction sheet provides information about DOP-107WV.
Before using the product, please read through this manual carefully in order to ensure the correct use of
the product. In addition, please place this manual safely for quick reference whenever is needed. Please
follow the rules below if you have not finished reading this manual yet.
(3) Part names
Power Input
A
B
COM2/ COM3
DOP-103WQ (Front view)
(24AWG wire min.)
C
E
COM1
D
F
Network Port (LAN)
USB Host
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids,
indoor use only.
USB Slave
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to the ground. The grounding method must comply with
the national electrical standard (Please refer to NFPA 70: National Electrical Code, 2005 Ed.
Do not modify the wiring or disassemble HMI interface when HMI is connected to the power.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
When HMI displays low power notification and requires battery changes, please contact local
distributors or DELTA customer service center for the replacement. Do not change batteries by
yourself.
DOP-110WS (Front view)
DOP-100 series can be used for industrial automation equipment. Please read through this
manual carefully and install the product according to the instructions in order to avoid danger.
Cleaning method: Please use dry cloth to clean the product.
The product should be used at an altitude below 2000 m.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.
For repairing and maintenance, please contact DELTA Electronics, Inc. Address: No.18, Xinglong
Rd., Taoyuan City, Taiwan. TEL: +886-3-3626301.
A
Touch Screen/Display
If you have any enquiry during operation, please contact our local distributors or Delta sales
representatives. The content of this instruction sheet may be revised without prior notice. Please consult
our distributors or download the latest version at http://www.delta.com.tw/ia.
DOP-103WQ (Rear view)
A
Touch Screen/Display
(2) Communication Port Pin Assignment
DOP-103WQ COM Port
DOP-110WS (Rear view)
MODE1
MODE2
COM1 COM2
MODE3
COM1
COM Port
Pin
COM1
COM2
COM2
RS-422
TXD+
RS-232
RS-485 RS-485 RS-485
D+
RS-232
1
2
3
4
5
6
7
8
9
RXD
TXD
RXD
TXD
D+
D-
D+
D-
RXD+
TXD-
GND
GND
GND
D-
C
A
C
Power Input (24AWG wire min.)
USB Slave
B
D
COM1
USB Host
RTS
CTS
RTS
CTS
RXD-
E
Network Port(LAN)
DOP-107WV / DOP-110WS COM1 Port
DOP-107WV (Front view)
MODE1
COM Port
Pin
Power Input
A
B
COM2/ COM3
(24AWG wire min.)
RS-232
C
E
G
COM1
D
F
Network Port (LAN)
USB Host
1
2
3
4
5
6
7
8
9
RXD
TXD
USB Slave
SD Card
GND
RTS
CTS
A
Touch Screen/Display
Model
Flash ROM
RAM
DOP-103WQ
DOP-107WV
256 Mbytes
512 Mbytes
DOP-110WS
Installation Method:
(4) Dimensions for Installation
Step 1:
Step 2:
DOP-103WQ
Put the waterproof gasket into HMI and then
insert the HMI into the panel cutout.
Place the fasteners into slots and tighten the
screws till reaching the panel cutouts.
4-wire resistive touch screen
> 10,000,000 operated
Touch Screen
Buzzer
Multi-Tone Frequency (2 K ~ 4 K Hz)/80 dB
(Note 2)
Ethernet Interface
10/100 Mbps Auto sensing (with built-in isolated power circuit
)
1 USB Slave Ver 2.0
1 USB Host Ver 2.0
USB
SD
N/A
SD * 1
RS-232 (supports flow control) (Note 2)
RS-232 (supports flow control) / RS-485(Note 2)
RS-422 / RS-485(Note 2)
RS-232 (supports flow
COM1
)
control) / RS-485(Note 2)
)
Serial
Communication
Port
COM2 RS-422 / RS-485(Note 2)
)
COM3
N/A
)
Step 3:
Step 4:
Function Keys
Perpetual Calendar
Cooling Method
N/A
Tighten the screws with torque less than 0.5N-M / For heat dissipation, please keep a minimum
0.7N-M to avoid damage to the plastic case.
DOP-107/DOP-110 Torque: 6.17 lb-inch (0.7N-M)
clearance of 60 mm on the rear of the HMI.
Built-in
Natural cooling
Operation Temperature is 0oC to 50oC and Storage Temperature is -20oC to +60oC
DOP-107WV
DOP-103 Torque: 4.41 lb-inch(0.5N-M)
CE / UL (Please use shielding Ethernet cable and the magnetic ring with filter of
300 ohm/100 MHz)
Safety Approval
Waterproof Level of
Panel Display
IP65(Not be evaluated by UL)/NEMA4/ Type 4X indoor use only
+24 VDC (-15% ~ +15%) (with built-in isolated power supply unit)
Supplied by Class 2 or SELV circuit (isolated from MAINS by double insulation)
Operation Voltage (Note2)
Voltage Endurance
500 VAC for 1 minute (between charging (DC24V terminal) and FG terminals)
Power Consumption (Note
5.8W (Max) (Note 3)
8.4W (Max) (Note 3)
11W (Max) (Note 3)
2)
Backup Battery
3V lithium battery CR2032 × 1
About 3 years or more at 25oC but subjects to the temperature and the conditions
during usage.
Backup Battery Life
0oC ~ 50oC
Operation Temperature
Storage Temperature
Operating Environment
-20oC ~ +60oC
10% ~ 90% RH [0 ~ 40oC], 10% ~ 55% RH [41 ~ 50oC]; Pollution degree: 2
Recommended wiring is as follows:
Vibration Resistance Conforms to IEC61131-2; Continuous: 5 Hz ~ 8.3 Hz 3.5 mm, 8.3 Hz ~ 150 Hz 1 G
Type
Solid
Wire Gauge (AWG)
24 ~ 12
Stripped length
7 ~ 8 mm
Torque
Shock Resistance
Conforms to IEC60068-2-27: 11 ms, 15 G Peak , X, Y, Z direction for 6 times
5 kg-cm (4.3 lb-in)
5 kg-cm (4.3 lb-in)
Stranded
24 ~ 12
7 ~ 8 mm
Dimension
(W) x (H) x (D) mm
137 x 103 x 37.1
196 x 136 x 39
270 x 180.9 x 47.25
Operation Temperature is 0oC to 50oC and Storage Temperature is -20oC to +60oC
DOP-110WS
Dimension for
Installation
(W) x (H) mm
Be sure to perform wiring by referring to the following figure (power supply connector), wiring must
be rated 75℃ min.
118.8 x 92.8
Approx.280g
186.8 x 126.8
Approx. 560 g
255 x 170
Weight
Approx. 1.1 Kgs
Note:
1. The half-life of backlight is defined as original luminance being reduced by 50% when the maximum
driving current is supplied to HMI. The life of LED backlight shown here is an estimated value under 25oC
normal temperature and humidity conditions.
2. The withstand voltage of the isolated power circuit is 1500 V peak for 1 minute.
3. Power consumption of HMI is the power consumed when not connecting to any peripheral devices. To
ensure normal operation of HMI, the recommended power supply is: power consumption x 1.5 ~ 2.
4. Isolated power supply is recommended.
5. DOPSoft, the program editor for DOP-100 series products and user manuals can be downloaded at
our website. In addition, the content of this instruction sheet may be revised without prior notice.
Please consult our distributors or download the latest version at http://www.delta.com.tw/ia.
6. DOP-100 series can be used for industrial automation equipment. Please read through this manual
carefully and install the product according to the instructions to avoid danger.
Operation Temperature is 0oC to 50oC and Storage Temperature is -20oC to +60oC
(6) Specifications
Model
DOP-103WQ
DOP-107WV
DOP-110WS
(5) Installation and Wiring
4.3" TFT LCD
7" TFT LCD
(65535 colors)
10.1" TFT LCD
(65535 colors)
Display Type
Installation Notes:
(65535 colors)
Improper installation will result in malfunction and greatly reduce the life of the HMI. Be sure to
follow the guidelines in this quick start when installing the HMI.
In order to ensure the HMI being well ventilated, make sure that the ventilation holes are not
obstructed and provide sufficient clearance for the HMI.
To protect the panel, be sure to install a waterproof gasket into HMI.
For use on a flat surface of a Type 4X "Indoor Use Only" enclosure or equivalent. If Enclosure with
lower type rating will cause de-rating.
Resolution
Backlight
480 x 272 pixels
800 x 480 pixels
1024 x 600 pixels
LCD
Module
LED Back Light (less than LED Back Light (less than LED Back Light (less than
10,000 hours half-life at
20,000 hours half-life at 30,000 hours half-life at 25
25oC) (Note 1)
25oC) (Note 1)
oC) (Note 1)
Display Size
Brightness
95.04 x 53.856 mm
400 cd/m² (Typ.)
154.08 x 85.92 mm
225.52 x 128.10 mm
450 cd/m² (Typ.)
450 cd/m² (Typ.)
The allowable thickness of the panel for mounting should be less than 5 mm.
CPU
ARM Cortex-A8 (800MHz)
相关型号:
©2020 ICPDF网 联系我们和版权申明