ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
0RQB-D0N12x RoHS Compliant PRELIMINARY Rev.A
•
•
•
•
•
•
•
•
•
Isolated
•
•
•
•
•
•
Output Over-voltage Protection
Over Temperature Protection
OCP /SCP
Fixed Frequency (280 kHz)
High Efficiency
High Power Density
Low Cost
Remote On/Off
Basic Isolation
Input Under-voltage Lockout
Input Over-voltage Lockout
Baseplate
Class 1, Category 2, Isolated DC/DC Converter (refer to IPC-9592)
UL60950-1 Recognized (UL/cUL) (Pending)
Applications
•
•
•
Networking
Computers and peripherals
Telecommunications
Description
The 0RQB-D0N12x is an isolated dc/dc converter that operates from a nominal 48 Vdc source. This unit will
provide up to 192 W of output power from a nominal 24 Vdc or 48 Vdc input. This unit is designed to be highly
efficient and low cost. Features include remote on/off, over current protection and overvoltage protection. The
converter is provided in an industry standard quarter brick package.
Part Selection
Output
Input Voltage
Max. Output
Current
Max. Output
Power
Typical Efficiency
( Vin=48 Vdc )
Model Number
Active Low
Model Number
Active High
Voltage
12 Vdc
18 Vdc - 60Vdc
16 A
192 W
94%
0RQB-D0N12L
0RQB-D0N120
Note: Add “G” suffix at the end of the model number to indicate Tray Packaging.
Part Number Explanation
0 R QB – D0 N 12 x
1 2
3
4
5 6 7
1---Through hole
2---RoHS 6, change “R” to “7” means RoHS 5
3---Series name
4---Series code
5---Input range (18-60V)
6---Output voltage (12V)
7---Suffix
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
1
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Absolute Maximum Ratings
Unit
V
Parameter
Min
-0.3
-
Typ
Max
60
Notes
Continuous Input Voltage
Input Transient Voltage
Remote On/Off
-
-
-
-
-
-
Non-operating
100 mS maximum
100
18
V
-0.3
-
V
I/O Isolation Voltage
Ambient Temperature
Storage Temperature
1500
85
V
-40
-55
°C
°C
125
Note: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may
permanently damage the device.
Input Specifications
Parameter
Min
Typ
Max
Unit
Notes
Operating Input Voltage
18
48
60
V
Input Current (full load)
Input Current (no load)
Remote Off Input Current
-
-
-
-
200
5
12
240
10
A
mA
mA
Input Reflected Ripple Current
(rms)
With simulated source impedance of
10uH, 5Hz to 20MHz. Use a
100uF/100V electrolytic capacitor with
ESR=1 ohm max, at 200KHz@25°C.
-
-
5
10
40
mA
Input Reflected Ripple Current
(pk-pk)
30
mA
I2t Inrush Current Transient
Turn-on Voltage Threshold
Turn-off Voltage Threshold
-
0.05
16.8
15.8
0.1
A2s
V
16
15
17.5
16.5
V
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
Recommend a fast-acting fuse with maximum rating of 20A on system board. Refer to the fuse
manufacture’s datasheet for further information.
Notes: 1. This converter has internal C-L-C (1uF-0.2uH-1uF-2.2uF*5) filter.
2. All specifications are typical at 25 °C unless otherwise stated.
Output Specifications
Parameter
Min
Typ
Max
Unit
Notes
Output Voltage Set Point
11.92
12
12.08
V
Vin=48V, Io=50% load
Load Regulation
Line Regulation
-
-
±20
±10
±50
±20
mV
mV
Regulation Over Temperature
(-40deg.C-85deg.C)
-
±100
±200
mV
Vin=48V, Full load, 0-20MHz BW, with a
1µF ceramic capacitor and a 10uF
Tantalum cap at output.
Ripple and Noise (pk-pk)
Ripple and Noise (rms)
-
-
100
25
150
40
mV
mV
Ripple and Noise (pk-pk)
under worst case
Over all operating input voltage, load
and ambient temperature condition
-
-
-
200
16
mV
A
Output Current Range
0
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
2
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Output Specifications (continued)
Parameter
Min
Typ
Max
Unit
Notes
Output DC Current Limit
18
22
25
A
Short Circuit Surge Transient
Rise time
-
-
-
5
-
A2s
ms
ms
ms
%
10
30
30
0
40
40
3
Enable form Vin
Turn on Time
-
-
Enable form ON/OFF
Overshoot at Turn on
Added additional capacitor to
decrease ripple and transient
response value.
Output Capacitance
220
-
2200
uF
Transient Response
Overshoot
-
-
-
-
400
120
400
120
600
200
600
200
mV
uS
△V50%~75% of
di/dt=0.1A/us, Vin=48Vdc, Ta=25°C,
with a 1µF ceramic capacitor and a
10uF Tantalum cap at output.
Max Load
Settling Time
Overshoot
mV
uS
△V75%~50% of
Max Load
Settling Time
Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
General Specifications
Parameter
Min
Typ
Max
Unit
Notes
Io=Io, max, full load
Efficiency
Vin=24V
Vin=48V
92.5
93
93.5
94
-
-
%
%
Switching Frequency
-
-
-
-
280
125
15.1
75
-
kHz
°C
V
Over Temperature Protection
Over Voltage Protection
Weight
130
15.5
-
This voltage is achieved by trimming
up output slowly.
g
Calculated Per Bell Core SR-332
(Vin=48V, Vo=48V, Io=8A, Ta = 25 °C,
FIT=109/MTBF)
FIT
TBD
-
-
Dimensions
Inches (L × W × H)
2.30 x 1.45 x 0.50
Millimeters (L × W × H)
58.42 x 36.83 x 12.70
Isolation characteristics
Input to Output
-
-
1500
V
V
Input to Case
-
-
1500
Output to Case
-
10M
-
-
-
500
V
Isolation Resistance
Isolation Capacitance
-
-
ohm
pF
1500
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
3
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Efficiency Data
99.00%
97.00%
95.00%
93.00%
91.00%
89.00%
87.00%
85.00%
83.00%
81.00%
79.00%
77.00%
75.00%
18 V
24 V
36 V
48 V
60 V
OUTPUT CURRENT(A)
Ripple and Noise Waveform
48Vdc input, 12Vdc/16A output
Note: Ripple and noise at full load, with a 1uF ceramic cap and a 10 uF Tantalum cap at output, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
4
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Transient Response Waveforms
Vout= 12V 50%-75% Load Transients
Vout= 12V 75%-50% Load Transients
Note: Transient Response at Vin=48V, di/dt=0.1A/uS, with a 1uF ceramic cap and a 10uF aluminum cap at the
output.
Startup & Shutdown
Rise Time
Vin = 24 V, Full Load Maximum capacitor
Vin = 48 V, Full Load Maximum capacitor
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
5
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Startup & Shutdown (continued)
Startup time
Startup from on/off
Ch1: Vo
Ch3: on/off
Vin = 48 V, Full Load Maximum capacitor
Startup from on/off
Ch1: Vo
Ch3: on/off
Vin = 24 V, Full Load Maximum capacitor
Shutdown
Vin = 24 V, Full Load
Vin = 48 V, Full Load
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
6
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Remote On/Off
Parameter
Min
Typ
Max
Unit
Notes
Signal Low (Unit On)
Signal High (Unit Off)
Signal Low (Unit Off)
Signal High (Unit On)
Current Sink
-0.3
-
0.8
V
0RQB-D0N12L
The remote on/off pin open, Unit off.
Active Low
Active High
2.4
-0.3
2.4
0
-
-
-
-
18
0.8
18
1
V
V
0RQB-D0N120
The remote on/off pin open, Unit on.
V
mA
Recommended remote on/off circuit for active low
Vin+
Vin+
On/off
Vin-
On/off
Vin-
Control with open collector/drain circuit
Control with photocoupler circuit
Vin+
Vin+
Vcc
On/off
On/off
Vin-
Vin-
Control with logic circuit
Permanently on
Recommended remote on/off circuit for active high
Vin+
On/off
Vin-
Vin+
On/off
Vin-
Control with open collector/drain circuit
Control with photocoupler circuit
Vin+
Vin+
Vcc
On/off
On/off
Vin-
Vin-
Control with logic circuit
Permanently on
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
7
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Output Trim Equations
Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected
between the Trim pin and Sense (-) pin. The Trim Up resistor should be connected between the Trim pin and the
Sense (+). Only one of the resistors should be used for any given application.
Minimum trim down voltage is 10.8V
Maximum trim up voltage is 13.2V.
The total voltage increased by trim and remote sense should not exceed 10% of the nominal output voltage.
Sense(+)
Module
511
Trim
Rtrimdown =
−10.22[kΩ
]
Rtrimdown
Rtrimup
delta
Sense(-)
Sense(+)
Trim
(100+delta)⋅Vo⋅5.11−626
1.225⋅delta
Module
Rtrimup=
−10.22
[
kΩ]
Sense(-)
Note:
(
Vo _ req −Vo
)
delta =
×100
[
%
]
Vo
Vo_req=Desired (trimmed) output voltage [V]
Output voltage Vo=12.036 V
600
480
360
240
120
0
2500
2000
1500
1000
500
0
12
1 2.24
12.48
12.7 2
12 .96
13.2
10.8
11.04
11.28
11.52
11.76
12
Vo,adj (V)
Vo,adj (V)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
8
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Remote Sense
This module has remote sense compensation feature. It can minimize the effects of resistance between
module’s output and load in system layout and facilitates accurate voltage regulation at load terminals or
other selected point.
1. The remote sense lines carries very little current and hence do not require a large cross-sectional area.
2. This module compensates for a maximum drop of 10% of the nominal output voltage.
3. If the unit is already trimmed up, the available remote sense compensation range should be
correspondingly reduced. The total voltage increased by trim and remote sense should not exceed 10%
of the nominal output voltage.
4. When using remote sense compensation, all the resistance, parasitic inductance and capacitance of the
system are incorporated within the feedback loop of this module. The can make an effect on the
module's compensation, affecting the stability and dynamic response. A 0.1uF ceramic capacitor can be
connected at the point of load to de-couple noise on the sense wires.
5. Recommend the connection of remote sense compensation as below figure. There are a resistor RS+
(100 ohm) from Vo+ to Sense+ and a resistor RS- (51 ohm)) from Vo- to Sense- inside of this module.
Vo+
Sense+
Load
Sense-
Vo-
6. If not using remote sense compensation, please connect sense directly to output at module's pin, that is,
connect sense+ to Vo+ and sense- to Vo- at module's pin, the shorter the better. See below figure.
Vo+
Sense+
Load
Sense-
Vo-
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
9
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Input Under-voltage Lockout
Under-voltage Lockout
V1=15.8V
V2=16.8V
Voltage Falling
Voltage Rising
Input Voltage (V)
V1
V2
Fundamental Circuit Diagram
1
8
4
3
7
Control
2
Isolated
Feedback
5
6
Choke
Capacitor
Resistor
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
10
ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Mechanical Outline
Pin Connections
pin# function pin size
1
2
3
4
5
6
7
8
Vin (+)
On/Off
Vin(-)
Vout(-)
RS-
Trim
RS+
Vout(+)
0.04"
0.04"
0.04"
0.06"
0.04"
0.04"
0.04"
0.06"
Note: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered
using a peak solder temperature of no more than 260 ºC for less than 5 seconds.
Note:
1) All Pins: Material - Copper Alloy;
Finish – 3 micro inches minimum Gold over 50 micro inches minimum Nickel plate.
2) Undimensioned components are shown for visual reference only.
3) All dimensions in inches (mm); Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm).
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
11
ISOLATED DC/DC CONVERTERS
18 Vdc – 60Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Revision History
Date
Revision
PA
Changes Detail
Approval
2010-11-17
First release
XF Jiang
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2010 Bel Fuse Inc. Specifications subject to change without notice. 111710
12
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
Bel Fuse Ltd.
Bel Fuse Europe Ltd.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com
相关型号:
©2020 ICPDF网 联系我们和版权申明