ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
0RHB-40TRxx RoHS Compliant
Rev.C
•
•
•
•
•
•
•
•
•
Isolated
•
•
•
•
•
Fixed Switching Frequency (110 kHz)
Output Short Circuit Protection
Input Under/Over Voltage Protection
Over Temperature Protection
CNT On/Off Logic
High Efficiency
Basic Insulation
Low Cost
Low THD Sine Wave Output
Excellent Thermal Performance
External Output Voltage Control 65 Vrms - 95 Vrms
External Digital Frequency Selection 17.5 Hz, 20 Hz, 25 Hz and 50 Hz
Overload Protection with Advanced Output Power Control
Description
The 0RHB-40TRxx is an isolated dc/ac ring generator that operates from a nominal 48 Vdc source. This unit
provides up to 40 W output power. It is designed to be highly efficient and low cost in a half-brick package.
Part Selection
Output Voltage
Input Voltage
Max. Output
Power
Typical
Efficiency
Model Number
Active High
Model Number
Active Low
65 Vac - 95 Vac
65 Vac - 95 Vac
36 Vdc - 75 Vdc
36 Vdc - 75 Vdc
40 W
40 W
85%
85%
0RHB-40TRG0
0RHB-40TRH0
0RHB-40TRGL
0RHB-40TRHL
Notes: 1. 0RHB-40TRGx indicates application 1, 0RHB-40TRHx indicates application 2, details please see page 5.
2. Add “G” suffix at the end of the model number to indicate Tray Packaging.
3. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Input Voltage (continuous)
I/O Isolation Voltage
Min
-0.3 V
-
Typ
-
-
Max
80 V
Notes
1500 Vac
Ambient Temperature
Storage Temperature
-
-
-40 °C
-50 °C
85 °C
115 °C
Input Specifications
Parameter
Min
Typ
Max
Notes
Input Voltage
36 V
48 V
75 V
Input Current (full load)
Input Current (no load)
-
-
-
-
1.5 A
60 mA
Tested with simulated source impedance
of 10 uH, 5 Hz to 20 MHz; use a 100 uF
/100 V electrolytic capacitor with ESR = 1
ohm max at 200 kHz at 25 °C.
Input Reflected Ripple Current (pk-pk)
-
-
150 mA
Turn-on Voltage Threshold
Under Voltage Threshold
Over Voltage Threshold
-
-
-
33 V
-
-
-
32 V
90 V
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Output Specifications
Parameter
Min
Typ
Max
Notes
Vin=48 V, Io=50% load. Trim pin
is connected to GND.
Output Voltage Set Point
92 V
95 V
98 V
Output Frequency
Load Regulation
Line Regulation
f-1.0 Hz
f Hz
f+1.0 Hz
2%Vo
-
-
1%Vo
0.5%Vo
1%Vo
Regulation Over Temperature
(-40deg.C - 85deg.C)
-
-
0.05%Vo/C
Voltage Accuracy
Frequency Accuracy
THD
-
3%Vo
5%Vo
3%Vo
5%
-
-
-
-
Output Current Range(95 Vac)
Output Power Limit
Turn on Time
0 mA
-
50 W
-
420 mA
-
-
-
Hiccup mode
1000 mS
Note: All specifications are typical at nominal input, full load at 25 °C unless noted.
General Specifications
Parameter
Min
Typ
Max
Notes
Efficiency
83%
85%
-
Vin=48 V, full load , Ta=25°C
Switching Frequency
100 kHz
110 kHz
120 kHz
Isolation capacitance
-
1500 pF
-
-
Output Voltage Trim Range
Over Temperature Protection
65 Vac
-
95 Vac
-
125 °C
Calculated Per Bell Core SR-332 (IO =
80%load; Ta = 25 °C)
MTBF
2,062,694 hours
Dimensions
Inches
millimeters
2.28 x 2.40 x 0.50
57.91 x 60.96 x 12.70
66 g
Weight
-
-
Note: All specifications are typical at 25 °C unless otherwise stated.
Control Specifications
Parameter
Min
Typ
Max
Notes
CNT On/Off
Signal High (Unit On)
Signal Low (Unit Off)
Signal High (Unit Off)
Signal Low (Unit On)
Current Source/Sink
36 V
-0.7 V
36 V
-
-
-
-
-
75 V
30 V
75 V
30 V
2 mA
Active High
Active Low
The CNT pin open, Unit on.
The CNT pin open, Unit off.
-0.7 V
0 mA
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Output Trim Equations
Equations for calculating the trim resistor is shown below. The Roac resistor should be connected between the
Trim pin and Gnd pin.
Vout
1292 / 23
Roac =
×4.7 −6.8(KΩ)
Module
Trim
Gnd
Vo −1292 / 23
Roac
56 V
65 V
70 V
75 V
80 V
85 V
90 V
95 V
Roac(kΩ)
Open
23.113
12.296
7.224
4.281
2.359
1.005
0
Efficiency Data
Efficiency Curve
95.0%
90.0%
85.0%
80.0%
75.0%
70.0%
65.0%
60.0%
36 V
48 V
75 V
10
20
30
40
Output Power(W)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Thermal Derating Curves
With maximum junction temperature of semiconductors derated to 120 degree C.
Vin=48 V
Frequency Setting
Output Frequency
OPTF1
OPTF2
(Hz)
17.5
20
OPTF1 and OPTF2:
0: Connected to GND
1: Open
0
0
1
1
0
1
0
1
25
50
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Typical Application
Typical Application 1 (0RHB-40TRGx)
Output AC is superimposed on DC bias – A single DC power supply is used for the Ring Generator feeding and
for the output biasing.
0RHB-40TRGx
+
-48V Rtn
Vo1(~) 10
1 V(+)
12uH /3A
TRIM
9
8
0V
Telephone
Ports
-48V
2 CNT
OPTF1
OPTF2
GND
7
6
220uF/100V 220uF/100V
220uF /100V
3 CASE
4 V(-)
-
Vo2(~)
5
-48V
Typical Application 2 (0RHB-40TRHx)
Output AC is superimposed on DC bias – Two DC power supplies are used, one for the Ring Generator feeding
and another for the output biasing.
0RHB-40TRHx
+
-48V Rtn
Vo1(~) 10
1 V(+)
12uH/3A
TRIM
9
8
2 CNT
OPTF1
OPTF2
GND
7
6
220uF/100V 220uF/100 V
220uF/100V
Telephone
Ports
3 CASE
4 V(-)
0V
-48V
Vo2(~)
5
-48V
DC Bias
48V
-
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Mechanical Outline
Pin Connections
pin function pin function pin
function
OPTF1
Trim
1
2
3
4
Vin(+)
CNT
Case
Vin(-)
5
6
7
Vo2(~)
GND
OPTF2
8
9
10
Vo1(~)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
INSTALLATION INSTRUCTION
1) The DC-AC Converter can be operated at an ambient temperature up to 85°C maximum.
2) The DC-AC Converter is a built-in component. During installation into certain equipment the relevant
requirements of EN 60950-1:2001 + A11 and IEC 60950-1:2001 shall be maintained.
3) The creepage distances, clearances and thickness of insulation between unearthed hazardous voltage input
and hazardous voltage output circuits have complied with basic insulation requirements according to EN
60950-1:2001 + A11 and IEC 60950-1:2001.
4) The output ratings as shown on the label must not be exceeded.
5) The equipment is to be supplied from a DC source which is separated from AC mains by double or reinforced
insulation, or by basic insulation and suitable earthing providing equivalent protection.
6) The equipment is intended to be installed into a class I or class II system, when installed into class I system,
protective earth has to be reliably identified and suitable external protection devices have to be provided in
the final system.
7) The equipment shall be installed with an external forced air-cooling according to installation instruction
accompanied with the unit. The airflow direction is towards the side of the equipment.
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2008 Bel Fuse Inc. Specifications subject to change without notice. 090508
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
Bel Fuse Ltd.
Bel Fuse Europe Ltd.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com
相关型号:
0RHB-40TRG0G
AC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid, ROHS COMPLIANT, HALF-BRICK PACKAGE-10
BEL
0RHB-C0Q150
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-9
BEL
0RHB-C0Q150G
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-9
BEL
0RHB-C5T033G
DC-DC Regulated Power Supply Module, 1 Output, 165W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL
©2020 ICPDF网 联系我们和版权申明