0RHB-40TRHL [BEL]

ISOLATED DC/AC CONVERTER; 隔离式DC / AC转换器
0RHB-40TRHL
型号: 0RHB-40TRHL
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

ISOLATED DC/AC CONVERTER
隔离式DC / AC转换器

转换器 电源电路
文件: 总7页 (文件大小:210K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ISOLATED DC/AC CONVERTER  
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output  
0RHB-40TRxx RoHS Compliant  
Rev.C  
Isolated  
Fixed Switching Frequency (110 kHz)  
Output Short Circuit Protection  
Input Under/Over Voltage Protection  
Over Temperature Protection  
CNT On/Off Logic  
High Efficiency  
Basic Insulation  
Low Cost  
Low THD Sine Wave Output  
Excellent Thermal Performance  
External Output Voltage Control 65 Vrms - 95 Vrms  
External Digital Frequency Selection 17.5 Hz, 20 Hz, 25 Hz and 50 Hz  
Overload Protection with Advanced Output Power Control  
Description  
The 0RHB-40TRxx is an isolated dc/ac ring generator that operates from a nominal 48 Vdc source. This unit  
provides up to 40 W output power. It is designed to be highly efficient and low cost in a half-brick package.  
Part Selection  
Output Voltage  
Input Voltage  
Max. Output  
Power  
Typical  
Efficiency  
Model Number  
Active High  
Model Number  
Active Low  
65 Vac - 95 Vac  
65 Vac - 95 Vac  
36 Vdc - 75 Vdc  
36 Vdc - 75 Vdc  
40 W  
40 W  
85%  
85%  
0RHB-40TRG0  
0RHB-40TRH0  
0RHB-40TRGL  
0RHB-40TRHL  
Notes: 1. 0RHB-40TRGx indicates application 1, 0RHB-40TRHx indicates application 2, details please see page 5.  
2. Add “G” suffix at the end of the model number to indicate Tray Packaging.  
3. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.  
Absolute Maximum Ratings  
Parameter  
Input Voltage (continuous)  
I/O Isolation Voltage  
Min  
-0.3 V  
-
Typ  
-
-
Max  
80 V  
Notes  
1500 Vac  
Ambient Temperature  
Storage Temperature  
-
-
-40 °C  
-50 °C  
85 °C  
115 °C  
Input Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
Input Voltage  
36 V  
48 V  
75 V  
Input Current (full load)  
Input Current (no load)  
-
-
-
-
1.5 A  
60 mA  
Tested with simulated source impedance  
of 10 uH, 5 Hz to 20 MHz; use a 100 uF  
/100 V electrolytic capacitor with ESR = 1  
ohm max at 200 kHz at 25 °C.  
Input Reflected Ripple Current (pk-pk)  
-
-
150 mA  
Turn-on Voltage Threshold  
Under Voltage Threshold  
Over Voltage Threshold  
-
-
-
33 V  
-
-
-
32 V  
90 V  
Note: All specifications are typical at 25 °C unless otherwise stated.  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/AC CONVERTER  
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output  
Output Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
Vin=48 V, Io=50% load. Trim pin  
is connected to GND.  
Output Voltage Set Point  
92 V  
95 V  
98 V  
Output Frequency  
Load Regulation  
Line Regulation  
f-1.0 Hz  
f Hz  
f+1.0 Hz  
2%Vo  
-
-
1%Vo  
0.5%Vo  
1%Vo  
Regulation Over Temperature  
(-40deg.C - 85deg.C)  
-
-
0.05%Vo/C  
Voltage Accuracy  
Frequency Accuracy  
THD  
-
3%Vo  
5%Vo  
3%Vo  
5%  
-
-
-
-
Output Current Range(95 Vac)  
Output Power Limit  
Turn on Time  
0 mA  
-
50 W  
-
420 mA  
-
-
-
Hiccup mode  
1000 mS  
Note: All specifications are typical at nominal input, full load at 25 °C unless noted.  
General Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
Efficiency  
83%  
85%  
-
Vin=48 V, full load , Ta=25°C  
Switching Frequency  
100 kHz  
110 kHz  
120 kHz  
Isolation capacitance  
-
1500 pF  
-
-
Output Voltage Trim Range  
Over Temperature Protection  
65 Vac  
-
95 Vac  
-
125 °C  
Calculated Per Bell Core SR-332 (IO =  
80%load; Ta = 25 °C)  
MTBF  
2,062,694 hours  
Dimensions  
Inches  
millimeters  
2.28 x 2.40 x 0.50  
57.91 x 60.96 x 12.70  
66 g  
Weight  
-
-
Note: All specifications are typical at 25 °C unless otherwise stated.  
Control Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
CNT On/Off  
Signal High (Unit On)  
Signal Low (Unit Off)  
Signal High (Unit Off)  
Signal Low (Unit On)  
Current Source/Sink  
36 V  
-0.7 V  
36 V  
-
-
-
-
-
75 V  
30 V  
75 V  
30 V  
2 mA  
Active High  
Active Low  
The CNT pin open, Unit on.  
The CNT pin open, Unit off.  
-0.7 V  
0 mA  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/AC CONVERTER  
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output  
Output Trim Equations  
Equations for calculating the trim resistor is shown below. The Roac resistor should be connected between the  
Trim pin and Gnd pin.  
Vout  
1292 / 23  
Roac =  
×4.7 6.8(KΩ)  
Module  
Trim  
Gnd  
Vo 1292 / 23  
Roac  
56 V  
65 V  
70 V  
75 V  
80 V  
85 V  
90 V  
95 V  
Roac(k)  
Open  
23.113  
12.296  
7.224  
4.281  
2.359  
1.005  
0
Efficiency Data  
Efficiency Curve  
95.0%  
90.0%  
85.0%  
80.0%  
75.0%  
70.0%  
65.0%  
60.0%  
36 V  
48 V  
75 V  
10  
20  
30  
40  
Output Power(W)  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/AC CONVERTER  
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output  
Thermal Derating Curves  
With maximum junction temperature of semiconductors derated to 120 degree C.  
Vin=48 V  
Frequency Setting  
Output Frequency  
OPTF1  
OPTF2  
Hz)  
17.5  
20  
OPTF1 and OPTF2:  
0: Connected to GND  
1: Open  
0
0
1
1
0
1
0
1
25  
50  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/AC CONVERTER  
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output  
Typical Application  
Typical Application 1 (0RHB-40TRGx)  
Output AC is superimposed on DC bias – A single DC power supply is used for the Ring Generator feeding and  
for the output biasing.  
0RHB-40TRGx  
+
-48V Rtn  
Vo1(~) 10  
1 V(+)  
12uH /3A  
TRIM  
9
8
0V  
Telephone  
Ports  
-48V  
2 CNT  
OPTF1  
OPTF2  
GND  
7
6
220uF/100V 220uF/100V  
220uF /100V  
3 CASE  
4 V(-)  
-
Vo2(~)  
5
-48V  
Typical Application 2 (0RHB-40TRHx)  
Output AC is superimposed on DC bias – Two DC power supplies are used, one for the Ring Generator feeding  
and another for the output biasing.  
0RHB-40TRHx  
+
-48V Rtn  
Vo1(~) 10  
1 V(+)  
12uH/3A  
TRIM  
9
8
2 CNT  
OPTF1  
OPTF2  
GND  
7
6
220uF/100V 220uF/100 V  
220uF/100V  
Telephone  
Ports  
3 CASE  
4 V(-)  
0V  
-48V  
Vo2(~)  
5
-48V  
DC Bias  
48V  
-
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/AC CONVERTER  
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output  
Mechanical Outline  
Pin Connections  
pin function pin function pin  
function  
OPTF1  
Trim  
1
2
3
4
Vin(+)  
CNT  
Case  
Vin(-)  
5
6
7
Vo2(~)  
GND  
OPTF2  
8
9
10  
Vo1(~)  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/AC CONVERTER  
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output  
INSTALLATION INSTRUCTION  
1) The DC-AC Converter can be operated at an ambient temperature up to 85°C maximum.  
2) The DC-AC Converter is a built-in component. During installation into certain equipment the relevant  
requirements of EN 60950-1:2001 + A11 and IEC 60950-1:2001 shall be maintained.  
3) The creepage distances, clearances and thickness of insulation between unearthed hazardous voltage input  
and hazardous voltage output circuits have complied with basic insulation requirements according to EN  
60950-1:2001 + A11 and IEC 60950-1:2001.  
4) The output ratings as shown on the label must not be exceeded.  
5) The equipment is to be supplied from a DC source which is separated from AC mains by double or reinforced  
insulation, or by basic insulation and suitable earthing providing equivalent protection.  
6) The equipment is intended to be installed into a class I or class II system, when installed into class I system,  
protective earth has to be reliably identified and suitable external protection devices have to be provided in  
the final system.  
7) The equipment shall be installed with an external forced air-cooling according to installation instruction  
accompanied with the unit. The airflow direction is towards the side of the equipment.  
RoHS Compliance  
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and  
other hazardous substances from electronic products.  
©2008 Bel Fuse Inc. Specifications subject to change without notice. 090508  
CORPORATE  
FAR EAST  
EUROPE  
Bel Fuse Inc.  
Bel Fuse Ltd.  
Bel Fuse Europe Ltd.  
206 Van Vorst Street  
Jersey City, NJ 07302  
Tel 201-432-0463  
Fax 201-432-9542  
www.belfuse.com  
8F/ 8 Luk Hop Street  
San Po Kong  
Kowloon, Hong Kong  
Tel 852-2328-5515  
Fax 852-2352-3706  
www.belfuse.com  
Preston Technology Management Centre  
Marsh Lane, Suite G7, Preston  
Lancashire, PR1 8UD, U.K.  
Tel 44-1772-556601  
Fax 44-1772-888366  
www.belfuse.com  

相关型号:

0RHB-40TRXX

ISOLATED DC/AC CONVERTER
BEL

0RHB-C0Q150

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-9
BEL

0RHB-C0Q150G

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-9
BEL

0RHB-C5T

ISOLATED DC/DC CONVERTERS 48 V Input 3.3 V/50 A, 5.0 V/30 A Output
BEL

0RHB-C5T033

ISOLATED DC/DC CONVERTERS
BEL

0RHB-C5T033G

DC-DC Regulated Power Supply Module, 1 Output, 165W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL

0RHB-C5T03L

ISOLATED DC/DC CONVERTERS 48 V Input 3.3 V/50 A, 5.0 V/30 A Output
BEL

0RHB-C5T03LG

DC-DC Regulated Power Supply Module, 1 Output, 165W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL

0RHB-C5T050

ISOLATED DC/DC CONVERTERS
BEL

0RHB-C5T050G

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL

0RHB-C5T05L

ISOLATED DC/DC CONVERTERS 48 V Input 3.3 V/50 A, 5.0 V/30 A Output
BEL

0RHB-C5T05LG

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL