NLP40-7608 [ARTESYN]
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES; 中低功率AC / DC电源型号: | NLP40-7608 |
厂家: | ARTESYN TECHNOLOGIES |
描述: | LOW TO MEDIUM POWER AC/DC POWER SUPPLIES |
文件: | 总3页 (文件大小:58K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
NLP40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies
1
• 4.25 x 2.5 x 1.15 inch package (1U applications)
• Smallest industry package
• Overvoltage and short circuit protection
• 40W with free air convection
• EN55022, EN55011 conducted emission level B
• EN61000-4-2, -3, -4, -5, -6 immunity compliant
• UL, VDE and CSA safety approvals
The NLP40 series is a 40W universal input AC/DC power supply on a 4.25 x 2.5 inch card
with a maximum component height of 1.15 inches for use in 1U applications. This
product is the smallest standard 40W package in the industry making the series ideal for
communication applications with space constraints where a standard 5 x 3 inch card
solution is not suitable. The NLP40 provides 40W of output power with free air convection
cooling which can be boosted to 50W with 20CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval
and the CE mark, meets conducted noise EN55022 level B and has immunity compliance
to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, POS terminals,
LCD projectors, cable modems and PABX’s. This list is not exclusive as the generic
feature set of the NLP40 series with industry standard output configurations provides a
solution for most low power applications including many industrial applications.
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Total regulation
(Line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Hold-up time
120VAC
230VAC
12ms @ 40W
20ms @ 40W
Rise time
At turn-on
1.0s, max.
Efficiency
75% typical
Transient response
Main output
25% step at 0.1A/µs 1ms rec. to 1.0%
5.0% max. dev.,
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Temperature coefficient
Overvoltage protection
Short circuit protection
±0.02% /°C
Switching frequency
Fixed
65kHz, ±5kHz
Main outputs
135% , ±15%
Continuous
Approvals and
standards (See Note 8)
EN60950, IEC950, UL1950
VDE0805, CSA C22.2 No. 950
Cyclic operation
Weight
200g (7.06oz)
Minimum output current Single
Multiple
0A
(See Note 5)
MTBF
MIL-HDBK-217F
150,000 hours min.
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input voltage range
(See Note 9)
Universal input
90 to 264VAC
120 to 370VDC
Thermal performance
(See Notes 6, 7, 9)
Operating ambient,
(see derating curve)
0°C to +70°C
Non-operating
-40°C to +70°C
Input frequency range
Input surge current
47Hz to 440Hz
50°C to 70°C ambient,
convection cooled
0°C to 50°C, ambient,
convection cooled
0°C to 50°C ambient,
20CFM forced air
Derate to
50% load
40W
120VAC, cold start
230VAC, cold start
15A max.
30A max.
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
0.2mA
0.4mA
50W
Peak (0°C to +50°C, 60s) (See Note 2)
Input current
120VAC
230VAC
1.4A rms
0.7A rms
Relative humidity
Altitude
Non-condensing
5% to 95% RH
Input fuse
UL/IEC127
250VAC H 3.15A
Operating
Non-operating
10,000 feet max.
30,000 feet max.
(10)
EMC CHARACTERISTICS
Vibration (See Note 4)
Shock
5Hz to 500Hz
2.4G rms peak
516.4 Part IV
Conducted emissions
Radiated emissions
ESD air
EN55022, FCC part 15
level B
level A
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 3
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
per MIL-STD-810E
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
File Name: NLP40.PDF Rev: 01 Jan 2000
NLP40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
2
OUTPUT CURRENT
OUTPUT
VOLTAGE
TOTAL
(3)
RIPPLE
MODEL NUMBER
(2)
(1)
MAX (1)
4.0A
2.0A
0.2A
4.0A
1.6A
0.2A
1.8A
1.8A
4.0A
2.0A
8.0A
3.3A
2.6A
1.6A
0.8A
PEAK
5.0A
3.0A
1.0A
5.0A
2.0A
1.0A
2.2A
2.2A
5.0A
3.0A
10A
FAN
REGULATION
(5)
+5V (IA)
+12V (IB)
–12V (IC)
+5V (IA)
+15V (IB)
–15V (IC)
+12V (IA)
-12V (IB)
+5V (IA)
+12V (IB)
5V
4.5A
50mV
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±2.0%
±5.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
NLP40-7608
3.0A
0.5A
4.5A
2.0A
0.5A
2.1A
2.1A
4.5A
3.0A
9.0A
4.0A
3.3A
2.0A
1.0A
120mV
120mV
50mV
(5)
NLP40-7610
150mV
150mV
120mV
120mV
50mV
(5)
NLP40-7627
(5)
NLP40-7629
120mV
50mV
NLP40-7605
NLP40-7612
NLP40-7615
NLP40-7624
NLP40-7617
12V
4.5A
3.6A
2.5A
1.1A
120mV
150mV
240mV
300mV
15V
24V
48V
Notes
DERATING CURVE
Output Power (Watts)
1
2
3
Maximum output power is 40W for natural convection cooling. With 20CFM
fan cooling, the maximum output power is 50W.
50W
40W
Peak output current lasting less than 60 seconds with duty cycle less than
5% . During peak loading, output voltage may exceed total reg. limits.
Figure is peak-to-peak. Output noise measurements are made across a
50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF
capacitor.
20 CFM FORCED AIR COOLING
4
5
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G
rms 5Hz to 500Hz.
For multiple output units (except -7627) to maintain stated regulation then:
0.25 ≤ I / I ≤ 5, for I > 0.3A
NATURAL
CONVECTION
COOLING
25W
20W
A
B
B
0.50 ≤ I / I ≤ 5, for I < 0.3A
A
B
B
For maximum output current I(C) on triple output models, i.e. for
= IMax., I min. ≥ 0.5A and I ≥ I .
I
C
A
A
B
For NLP40-7627 only, to maintain stated regulation then:
0.5 ≤ I / I ≤ 2.
A
B
6
7
8
9
For optimum reliability, no part of the heatsink should exceed 120°C, and
no semiconductor case temperature should exceed 130°C.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
0°C
10°C
20°C
30°C
40°C
50°C
60°C
70°C
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
When the input voltage is <90VAC the operating range is 0°C to +40°C.
10 For system EMI compliance, a ground choke may be
required before connecting the ground wire to the
chassis. It is recommended that this ground choke be
placed as close as possible to the systems AC inlet to
eliminate noise pick-up in the system.
INPUT
OUTPUT PIN CONNECTIONS
PIN CONNECTIONS
J 1
J 2
SINGLE
+Vout
DUAL
V (B)
TRIPLE
V (B)
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 1
AC Line
No Pin
+Vout
V (A)
V (A)
Pin 2
Pin 3
+Vout
V (A)
V (A)
AC Neutral
Return
Return
Return
Return
Return
Return
Return
Return
V (C)
P1
Safety Ground
Pin 1
www.a rte s yn.com
File Name: NLP40.PDF Rev: 01 Jan 2000
NLP40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
3
4.25
(107.95)
0.125
(3.175)
4.00
(101.60)
J1
N
F1
1
L
2.50
(63.50)
2.25
(57.15)
J2
P1
T1
C5
Mounting
MAXIMUM COMPONENT
HEIGHT 1.15 (29.21)
Hole Diameter
ALL DIMENSIONS IN INCHES (mm)
0.138 (3.50) Typical
TOLERANCE: .xxx
.xx
±
±
0.005"
0.02"
Input and output connectors Mating connectors
AC (J 1) connector type
AC (J 1) mating connector type
Molex 26-60-4030 type.
Molex 09-50-3031 or equivalent with Molex 08-50-0105
or equivalent crimp terminals.
DC (J 2) connector type
DC (J 2) mating connector type
Molex 26-60-4060 type.
Molex 09-50-3061 with Triurcon 6838 or equivalent
crimp terminals.
Note: The input and output connectors are the same as
those used on NFS40, NFN40, NAL40 and NAN40.
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. pending
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Data Sheet © Artesyn Technologies
® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.a rte s yn.com
File Name: NLP40.PDF Rev: 01 Jan 2000