NLP40-7608J [EMERSON-NETWORKPOWER]
40-50 W AC/DC Universal Input Switch Mode Power Supplies; 40-50 W AC / DC通用输入开关电源型号: | NLP40-7608J |
厂家: | EMERSON NETWORK POWER |
描述: | 40-50 W AC/DC Universal Input Switch Mode Power Supplies |
文件: | 总3页 (文件大小:91K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
NLP40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40-50 W AC/DC Universal Input Switch Mode Power Supplies
1
• 4.25 x 2.5 x 1.15 inch package (1U applications)
• Smallest industry package
• Overvoltage and short circuit protection
• 40 W with free air convection
• EN55022, EN55011 conducted emission level B
• EN61000-4-2, -3, -4, -5, -6 immunity compliant
• UL, VDE and CSA safety approvals
• Available RoHS compliant
The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card
with a maximum component height of 1.15 inches for use in 1U applications. This product is
the smallest standard 40 W package in the industry making the series ideal for
communication applications with space constraints where a standard 5 x 3 inch card
solution is not suitable. The NLP40 provides 40 W of output power with free air convection
cooling which can be boosted to 50 W with 20 CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval and
the CE mark, meets conducted noise EN55022 level B and has immunity compliance to
EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, POS terminals, LCD
projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of
the NLP40 series with industry standard output configurations provides a solution for most
low power applications including many industrial applications.
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Total regulation
(Line and load)
Main output
Auxiliary outputs
2.0%
5.0%
Hold-up time
120 Vac
230 Vac
12 ms @ 40 W
20 ms @ 40 W
Rise time
At turn-on
1.0 s, max.
Efficiency
75% typical
Transient response
Main output
25% step at 0.1 A/µs 1 ms rec. to 1.0%
5.0% max. dev.,
Isolation voltage
Input/output
Input/chassis
3000 Vac
1500 Vac
Temperature coefficient
Overvoltage protection
Short circuit protection
0.02%/°C
Switching frequency
Fixed
65 kHz, 5 kHz
Main outputs
135%, 15%
Continuous
Approvals and
standards (See Note 8)
EN60950, IEC950, UL1950
VDE0805, CSA C22.2 No. 950
Cyclic operation
Weight
200 g (7.06 oz)
Minimum output current Single
Multiple
0 A
(See Note 5)
MTBF
MIL-HDBK-217F
150,000 hours min.
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input voltage range
(See Note 9)
Universal input
90-264 Vac
120-370 Vdc
Thermal performance
(See Notes 6, 7, 9)
Operating ambient,
(see derating curve)
0 °C to +70 °C
Non-operating
50 °C to 70 °C ambient,
convection cooled
0 °C to 50 °C, ambient,
convection cooled
0 °C to 50 °C ambient,
20 CFM forced air
-40 °C to +70 °C
Input frequency range
Input surge current
47-440 Hz
Derate to
50% load
40 W
120 Vac, cold start
230 Vac, cold start
15 A max.
30 A max.
Safety ground
leakage current
120 Vac, 60 Hz
230 Vac, 50 Hz
0.2 mA
0.4 mA
50 W
Peak (0 °C to +50 °C, 60 s) (See Note 2)
Input current
120 Vac
230 Vac
1.4 A rms
0.7 A rms
Relative humidity
Altitude
Non-condensing
5% to 95% RH
Input fuse
UL/IEC127
250 Vac H 3.15 A
Operating
Non-operating
10,000 feet max.
30,000 feet max.
EMC CHARACTERISTICS (10)
Vibration (See Note 4)
Shock
5-500 Hz
2.4 G rms peak
516.4 Part IV
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
level B
level A
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 3
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
per MIL-STD-810E
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
File Name: nlp40.pdf Rev (03): 08 Nov 2005
NLP40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40-50 W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
VOLTAGE
TOTAL
RIPPLE (3)
MODEL NUMBER (11,12)
MAX (1)
4 A
PEAK (2)
5 A
FAN (1)
4.5 A
3 A
REGULATION
+3.3 V (IA)
+12 V (IB)
–12 V (IC)
+5 V (IA)
+12 V (IB)
–12 V (IC)
+5 V (IA)
+15 V (IB)
–15 V (IC)
+12 V (IA)
-12 V (IB)
+5 V (IA)
+12 V (IB)
3.3 V (IA)
5 V
50 mV
120 mV
120 mV
50 mV
2.0%
5.0%
5.0%
2.0%
5.0%
5.0%
2.0%
5.0%
5.0%
2.0%
5.0%
2.0%
5.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
NLP40-76T366J (5)
2 A
3 A
0.2 A
4 A
1 A
0.5 A
4.5 A
3 A
5 A
NLP40-7608J (5)
NLP40-7610J (5)
2 A
3 A
120 mV
120 mV
50 mV
0.2 A
4 A
1 A
0.5 A
4.5 A
2 A
5 A
1.6 A
0.2 A
1.8 A
1.8 A
4 A
2 A
150 mV
150 mV
120 mV
120 mV
50 mV
1 A
0.5 A
2.1 A
2.1 A
4.5 A
3 A
2.2 A
2.2 A
5 A
NLP40-7627J (5)
NLP40-7629J (5)
2 A
3 A
120 mV
50 mV
8 A
10 A
10 A
4.5 A
3.6 A
2.5 A
1.1 A
9 A
NLP40-76S3J
NLP40-7605J
NLP40-7612J
NLP40-7615J
NLP40-7624J
NLP40-7617J
8 A
9 A
50 mV
12 V
3.3 A
2.6 A
1.6 A
0.8 A
4 A
120 mV
150 mV
240 mV
300 mV
15 V
3.3 A
2 A
24 V
48 V
1 A
Notes
DERATING CURVE
Output Power (Watts)
1
2
3
Maximum output power is 40 W for natural convection cooling. With
20 CFM fan cooling, the maximum output power is 50 W.
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total reg. limits.
Figure is peak-to-peak. Output noise measurements are made across a
50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF
capacitor.
50W
40W
20 CFM FORCED AIR COOLING
4
5
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
For multiple output units (except -7627J, 76T366J) to maintain stated
regulation then:
25W
20W
NATURAL
CONVECTION
COOLING
0.25 ≤ I / I ≤ 5, for I > 0.3 A
A
B
B
0.50 ≤ I / I ≤ 5, for I < 0.3 A
A
B
B
For maximum output current I(C) on triple output models, i.e. for
= IMax., I min. ≥ 0.5 A and I ≥ I .
I
C
A
A
B
For NLP40-7627J only, to maintain stated regulation then:
0.5 ≤ I / I ≤ 2.
For NLP40-76T366J only, to maintain stated regulation then:
0.25 ≤ I / I ≤ 4.
A
B
A
B
6
7
8
9
For optimum reliability, no part of the heatsink should exceed 120 °C, and
no semiconductor case temperature should exceed 130 °C.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
When the input voltage is <90 Vac the operating range is 0 °C to +40 °C.
0°C
10°C
20°C
30°C
40°C
50°C
60°C
70°C
10 For system EMI compliance, a ground choke may be required before
connecting the ground wire to the chassis. It is recommended that this
ground choke be placed as close as possible to the systems ac inlet to
eliminate noise pick-up in the system.
11 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
12 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
File Name: nlp40.pdf Rev (03): 08 Nov 2005
NLP40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40-50 W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
4.25
(107.95)
0.125
(3.175)
4.00
(101.60)
J1
F1
N
1
L
2.50
(63.50)
2.25
(57.15)
J2
P1
T1
C5
Mounting
Hole Diameter
0.138 (3.50) Typical
MAXIMUM COMPONENT
HEIGHT 1.15 (29.21)
ALL DIMENSIONS IN INCHES (mm)
TOLERANCE: .xxx
.xx
±
±
0.005"
0.02"
Input and output connectors
AC (J1) connector type
Molex 26-60-4030 type.
INPUT
DC (J2) connector type
Molex 26-60-4060 type.
PIN CONNECTIONS
J1
Pin 1
Pin 2
Pin 3
AC Line
No Pin
Mating connectors
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp
terminals.
AC Neutral
P1
Safety Ground
DC (J2) mating connector type
Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals.
Note: The input and output connectors are the same as
those used on NFS40, NFN40, NAL40 and NAN40.
Pin 1
OUTPUT PIN CONNECTIONS
J2
SINGLE
DUAL
TRIPLE
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
+Vout
V (B)
V (B)
+Vout
V (A)
V (A)
+Vout
V (A)
V (A)
International Safety Standard Approvals
Return
Return
Return
Return
Return
Return
Return
Return
V (C)
VDE0805/EN60950/IEC950 File 10401-3336-0093
Licence No. 93662
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Datasheet © Artesyn Technologies
® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: nlp40.pdf Rev (03): 08 Nov 2005
相关型号:
©2020 ICPDF网 联系我们和版权申明