LCM600L-N [ARTESYN]

AC/DC CONVERTER 12V 600W;
LCM600L-N
型号: LCM600L-N
厂家: ARTESYN TECHNOLOGIES    ARTESYN TECHNOLOGIES
描述:

AC/DC CONVERTER 12V 600W

文件: 总11页 (文件大小:914K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ARTESYN LCM600  
600 Watt Bulk Front End  
Advanced Energy's Artesyn LCM600 series of 2U high  
distributed power front-end AC-DC power supplies  
provides a very cost effective bulk power solution. The series  
comprises five models, offering outputs of 12 V, 15 V, 24 V,  
36 V or 48 V, together with an optional 5 V standby output.  
Each model accepts a universal input of 85–264 Vac and has  
a typical full load efficiency of 89%. Carrying industrial and  
medical safety approvals, these power supplies can deliver  
up to 600 watts and offer versatile bulk power for a wide  
variety of industrial, medical, military and process automation  
applications.  
DATA SHEET  
Total Power:  
600 W  
# of Outputs:  
Single  
Outputs:  
12 to 60 V  
Optional 5.0 V standby  
SPECIAL FEATURES  
COMPLIANCE  
600 W output power  
Low cost  
EMI Class B  
EN61000 Immunity  
2.4” x 4.5” x 7.5”  
SAFETY  
7.41 W/cu-in  
Industrial/Medical safety  
-40 °C to 70 °C with derating  
Optional 5 V @ 2 A housekeeping  
High efficiency: 89% typical  
Variable speed “Smart Fans”  
DSP controlled front end  
Conformal coat option  
UL/CSA  
TUV  
UL/CSA62368-1  
EN62368-1  
CB Report  
IEC60950-1,  
IEC60601-1  
CCC  
GB4943, GB9254  
and GB17625  
UL/CSA  
TUV  
ES60601-1/CSA  
C22.2 No. 60601-1  
20% adꢀustment range  
EN60601-1  
Margin programming  
OR-ing FET  
** LCM600 tested according to the  
medical standard IEC 60601-1-2 4th  
Edition.  
Terminal block input option  
©2021 Advanced Energy Industries, Inc.  
LCM600  
ELECTRICAL SPECIFICATIONS  
Input  
Input range  
85 - 264 Vac (Operating)  
115/230 Vac (Nominal) Input through standard IEC connector/  
TERMINAL BLOCK  
Frequency  
47 - 440 Hz, Nominal 50/60  
Input fusing  
Inrush current  
Power factor  
Internal 10 A fuses, both lines fused  
≤ 25 A peak, either hot or cold start  
0.99 typical, meets EN61000-3-2  
Harmonics  
Meets IEC 1000-3-2 requirements  
Input current  
Hold up time  
Efficiency  
8 A RMS max input current, at 100 Vac  
20 ms minimum for main O/P, at full rated load  
> 89% at full load  
Leakage current  
< 0.3 mA at 240 Vac  
ON/OFF power switch  
Power line transient  
Isolation  
N/A  
MOV directly after the fuse  
Isolation: PRI-Chassis 2500 Vdc Basic  
PRI-SEC 4000 Vac Reinforced 2xMOPP  
SEC-Chassis 500 Vdc  
LCM600Q Efꢀciency Without the 5 Vsb  
92.00  
90.00  
88.00  
86.00  
84.00  
82.00  
80.00  
78.00  
76.00  
100 Vac  
230 Vac  
25  
50  
75  
100  
Loading %  
2
advancedenergy.com  
LCM600  
ELECTRICAL SPECIFICATIONS (CONTINUED)  
Output  
Output rating  
Set point  
See ordering information table  
0.5%  
85 - 264 Vac  
85 - 264 Vac  
Total regulation range  
Main output 2%  
5 Vsb 1%  
Combined line/load/transient when measured at output terminal  
Rated load  
600 W maximum  
Derate linear to 50% from 50 °C to 70 °C  
No loss of regulation  
Minimum load  
Main output @ 0.0 A  
5 Vsb @ 0.0 A  
Output noise (PARD)  
1% max p-p 50 mV max p-p  
Main output  
5 Vsb output  
Measured with a 0.1 μF Ceramic and 10 μF Tantalum Capacitor on  
any output, 20 MHz  
Output voltage overshoot  
Transient response  
< 300 μSec  
No overshoot/undershoot outside the regulation band during on  
or off cycle  
50% load step @ 1 A/μs  
Step load valid between 10% to 100% of output rating  
Recovery time to within 1% of set point at onset of transient  
Max units in parallel  
Short circuit protection  
Remote sense  
Up to 10  
Protected, no damage to occur  
Bounce mode  
Compensation up to 500 mV  
Standard per safety requirements  
Analog sharing control  
Output isolation  
Forced load sharing  
Overload protection (OCP)  
To within 10% of all shared outputs  
105% to 125%  
120% to 170%  
Main output  
5 Vsb output  
Overvoltage protection (OVP)  
125% to 145%  
110% to 125%  
12 V output  
5 Vsb output  
Overtemp protection  
Fan Fault Protection  
10 - 15 °C above safe operating area  
Both PFC and output converter monitored  
For-N option only. Will shutdown output and DC_OK  
ENVIRONMENTAL SPECIFICATIONS  
Operating temperature  
Storage temperature  
Humidity  
-40 °C to +70 °C, linear derating to 50% from 50 °C to 70 °C  
-40 °C to +85 °C  
10 to 90%, non-condensing. Operating. Conformal coat option available  
Fan noise  
< 45 dBA, 80% load at 30 °C “-N” Low Noise Option < 35 dBA, 80% Load at 30 °C  
Altitude  
Operating - 16,404.2 feet  
Storage - 30,000 feet  
Shock  
MIL-STD-810F 516.5, Procedure I, VI. Storage  
MIL-STD-810F 514.5, Cat. 4, 10. Storage  
Vibration  
advancedenergy.com  
3
LCM600  
ORDERING INFORMATION  
Current  
Nominal Output  
Voltage Set  
Point  
Output  
Ripple  
Max  
Continuous  
Power  
Combined  
Line/Load  
Regulation  
Model  
Set Point  
Tolerance  
Adjustment  
Range  
Min  
Max  
Number*  
Output  
12 V  
P/P (0-50 ˚C)  
LCM600L  
12 V  
15 V  
24 V  
36 V  
48 V  
0.5%  
0.5%  
0.5%  
0.5%  
0.5%  
9.6 - 14.4 V  
12.0 - 19.5 V  
19.2 - 28.8 V  
28.8 - 43.2 V  
38.4 - 57.6 V  
0 A  
0 A  
0 A  
0 A  
0 A  
52 A  
44 A  
120 mV  
150 mV  
240 mV  
240 mV  
280 mV  
600 W  
600 W  
600 W  
600 W  
600 W  
2%  
2%  
2%  
2%  
2%  
LCM600N  
LCM600Q  
LCM600U  
LCM600W  
15 V  
24 V  
27 A  
36 V  
16.7 A  
14 A  
48 V  
*Note: Add “-T” for terminal block instead of IEC input  
Add “-N” for low noise model on 12 V or 24 V models  
Add “-4” for 5 V Standby output  
Add “-A” will be automatically added to all orders to denote new Aesthetics style chassis unless otherwise specified  
Example: a 24 V with terminal block, low noise and standby with new Aesthetics would be LCM600Q-T-N-4-A  
PIN ASSIGNMENT  
Signals  
+Vout  
GND  
Name Description  
Power rail  
Pin Number(s)  
SK4  
Power GND  
SK5  
Signals  
A2  
Name Description  
EEPROM Address  
SK2 Pin Number  
1
2
-VPROG  
Return connection of external supply for Margin  
Programming  
A1  
EEPROM Address  
3
4
-Vsense  
Remote Sense Return  
ISHARE  
Load share voltage  
5
A0  
EEPROM Address  
6
7
SDA1  
+VPROG  
Serial Data Signal (I2C)  
Positive connection of external supply for Margin  
Programming  
8
SCL1  
Serial Clock Signal (I2C)  
Remote Sense Positive  
5V standby  
9
+Vsense  
5VSB  
10  
11  
12  
13  
14  
15  
16  
GND  
5V standby Return  
5VSB  
5V standby  
G_DCOK_C  
GPIOA6  
G_DCOK_E  
GND  
Global DCOK Collector  
EEPROM Write Protect  
Global DCOK Emitter (GND)  
Return Ground for output signal and I2C  
communication  
17  
G_ACOK_C  
INH_EN  
Global ACOK Collector  
Turn Off Main Output  
18  
19  
20  
G_ACOK_E  
Global ACOK Emitter (GND)  
Note: Mating connector for SK2 is:  
LANDWIN: PN 2050S2000 Housing and PN 2053T021V Contact  
CIVILUX: PN CI0120SD000 Housing and PN CI01TD21PE0 Contact  
JST: PN PHDR-20VS housing and PN: SPHD-001T-P0.5  
Signal Output Signal Connectors (SK2)  
SK2 Mating Connector: JST Part Number PHDR-20VS;  
Contact Pins: JST Part Number SPHD-001T-P0.5  
4
advancedenergy.com  
LCM600  
PIN ASSIGNMENT (CONTINUED)  
LED Indicators  
Two (2) provided are clearly visible up to a 45 degree offset from vertical with office environment ambient lighting. The  
status is reflected in the indicator color.  
The DC_OK LED LED is bicolor. It shall light green if the DC output is within specification, and amber if the output falls  
out of specification.  
The AC_OK LED LED is green if the AC is within specification and off when out of specification. Note: With 5 V standby,  
Amber also indicates that PSU is in standby mode/output off.  
Control Signals  
AC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided.  
DC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided.  
DC_OK will de-assert when output is loss due to OCP, OVP, OTP, or Fan Fault (for -N option).  
PS_INHIBIT/ENABLE Signal 0.0 - 0.5 V contact closure, output OFF  
ORDERING INFORMATION  
LCMXXXXY  
-
A
-
B
-
C
-
###  
Case Size  
Input Termination  
Acoustic Noise  
Option Codes  
Hardware Code  
1-Phase input where XXXX =  
600 = 2.4” x 4.5” x 7.5”, 600 W  
Blank = IEC connector  
T = Terminal Block  
Blank = Standard  
N = Low Noise Fan  
Blank = No Options  
Factory Assigned for  
Modiefied standards  
1 = Conformal Coat  
4 = 5 V Standby  
5 = Opt 1 + 4  
Voltage Code Y =  
Code  
L
12  
15  
24  
36  
48  
N
Q
U
W
advancedenergy.com  
5
LCM600  
MECHANICAL DRAWINGS  
(212.2 ref)  
190.5 0.5  
(18.5)  
SEE DETAIL A  
SEE DETAIL C (TRIMPOT LOCATION)  
GROUND  
NEUTRAL  
LIVE  
DETAIL A  
SCALE 1.500  
SCREW-MC PHILIP PAN  
WITH WASHER M4x8  
(8X) MOUNTING LOCATIONS  
BOTH SIDES  
M4X0.7P THREAD  
SEE NOTE 7  
BRAND LOGO  
SEE DETAIL B  
INPUT TERMINAL BLOCK  
SEE NOTE 8  
(2X)6 0.5  
(2X)10.6  
50  
SK4 & SK5  
LED (AC OK)  
(2X)182.5 0.5  
(2X)177.5 0.5  
LED (DC/OK FAIL)  
SK2 SIGNAL  
CONNECTOR - 20WAY  
(2X)10 0.5  
VOLTAGE ADJUSTMENT:  
CLOCKWISE - INCREASE VOLTAGE  
COUNTER CLOCKWISE - DECREASE VOLTAGE  
DETAIL C  
(TRIMPOT LOCATION)  
(4X) MOUNTING LOCATIONS  
M4X0.7P THREAD  
SEE NOTE 7  
DETAIL B  
AC INLET VERSION  
New Mechanical Reference Drawing:  
Weight: 2.84 lbs (1.29 Kg)  
Note 7 RECOMMENDED SCREW TORQUE:  
M3.5x0.6P = 6-8kgf-cm  
MOUNTING LOCATIONS SCREW  
PENETRATION DEPTH IS 4.6 mm MAX.  
M4.0x0.7P = 8-10kfg-cm  
Note 8 INPUT: TERMINAL BLOCK TYPE.  
M3.5 SCREW TORQUE VALUE OF 12kgf-cm  
USING WIRE GAUGE 22-19 (9.5mm CENTERS)  
RECOMMENDED SCREW TORQUE:  
M3.5 x 0.6P = 6 - 8kgf-cm  
M4.0 x 0.7P = 8 - 10kgf-cm  
NOTE: OPTIONAL BARRIER STRIP OUTPUT TERMINAL AVAILABLE  
OPTIONAL MOLEX TYPE CONNECTOR OUTPUT AVAILABLE  
6
advancedenergy.com  
LCM600  
MECHANICAL DRAWINGS – TERMINAL BLOCK INPUT  
190,5 0,5  
SEE DETAIL  
A
18,5 REF  
SEE DETAIL B (TRIMPOT LOCATION)  
GROUND  
NUETRAL  
LIVE  
DETAIL  
A
SCALE 8:5  
SCREW-MC PHILIP PAN  
WITH EXT-T WASHER  
M3.5 x P0.6 x 6  
INPUT TERMINAL BLOCK  
SEE NOTE 8  
PROVISION FOR FUTURE  
LABEL REQUIREMENTS  
PRODUCT LABEL  
(8X) MOUNTING LOCATIONS  
BOTH SIDES  
M4X0.7P THREAD  
SEE NOTE 7  
LED (DC/OK FAIL)  
LED (AC OK)  
POS - SK4  
NEG - SK5  
(2X)6 0,5  
(2X)10,6  
50  
(2X)182,5 0,5  
(2X)177,5 0,5  
SK2 SIGNAL CONNECTOR - 20WAY  
(2X)10 0,5  
VOLTAGE ADJUSTMENT:  
(4X) MOUNTING LOCATIONS  
M4X0.7P THREAD  
SEE NOTE 7  
CLOCKWISE - INCREASE VOLTAGE  
COUNTER CLOCKWISE - DECREASE VOLTAGE  
DETAIL B  
(TRIMPOT LOCATION)  
AIRFLOW DIRECTION  
Old Mechanical Reference Drawing:  
Weight: 2.84 lbs (1.29 Kg)  
Note 7 - RECOMMENDED SCREW TORQUE:  
M3.5x0.6P = 6-8kgf-cm  
M4.0x0.7P = 8-10kfg-cm  
advancedenergy.com  
7
LCM600  
LOW NOISE VS. NON-LOW NOISE LCM600 MODEL  
60.0  
58.0  
56.0  
54.0  
52.0  
50.0  
48.0  
46.0  
44.0  
42.0  
40.0  
38.0  
36.0  
34.0  
32.0  
30.0  
25 Deg Ambient  
NON-Low noise version  
Low noise version  
0
2.5  
5
7.5  
10  
12.5  
15  
17.5  
20  
22.5  
25  
27.5  
30  
32.5  
35  
37.5  
40  
42.5  
45  
47.5  
50  
LOAD(A)  
60.0  
58.0  
56.0  
54.0  
52.0  
50.0  
48.0  
46.0  
44.0  
42.0  
40.0  
38.0  
36.0  
34.0  
32.0  
30.0  
50 Deg Ambient  
NON-Low noise version  
Low noise version  
0
2.5  
5
7.5  
10  
12.5  
15  
17.5  
20  
22.5  
25  
27.5  
30  
32.5  
35  
37.5  
40  
42.5  
45  
47.5  
50  
LOAD(A)  
NON-LOW NOISE VERSION  
25 ˚C ambient  
RPM  
50 ˚C ambient  
RPM  
LOAD (A)  
Fan (V)  
Noise (dbA)  
Fan (V)  
Noise (dbA)  
0
6.254  
6.257  
6.262  
6.263  
6.242  
6.251  
6.251  
6.226  
6.223  
6.242  
6.253  
6.254  
6.253  
6.264  
6.262  
6.262  
6.262  
7.637  
8.919  
10.068  
11.362  
3558.0  
3559.8  
3562.0  
3562.0  
3528.9  
3530.9  
3538.3  
3538.2  
3541.0  
3545.1  
3553.9  
3564.1  
3552.2  
3559.7  
3559.6  
3560.8  
3559.8  
4521.2  
5362.2  
6139.5  
6893.4  
40.9  
41.0  
41.0  
41.0  
40.5  
40.6  
40.7  
40.7  
40.7  
40.8  
40.9  
41.0  
40.9  
41.0  
41.0  
41.0  
41.0  
47.8  
49.3  
51.0  
52.8  
6.228  
6.228  
6.230  
6.242  
6.242  
6.237  
6.229  
6.205  
6.217  
6.227  
6.234  
6.212  
6.642  
7.893  
9.153  
11.035  
11.605  
11.608  
11.608  
11.608  
11.608  
3460.9  
3460.9  
3494.3  
3526.6  
3526.6  
3515.6  
3504.9  
3482.8  
3490.1  
3493.8  
3504.3  
3501.7  
3787.4  
4652.3  
5463.4  
6600.2  
6993.9  
6997.2  
6997.2  
6997.2  
6997.2  
39.9  
39.9  
40.1  
40.1  
40.1  
40.4  
40.2  
39.4  
40.0  
40.1  
40.2  
40.2  
44.1  
48.0  
50.0  
52.0  
53.2  
53.2  
53.2  
53.2  
53.2  
2.5  
5
7.5  
10  
12.5  
15  
17.5  
20  
22.5  
25  
27.5  
30  
32.5  
35  
37.5  
40  
42.5  
45  
47.5  
50  
8
advancedenergy.com  
LCM600  
LOW NOISE VERSION  
25 ˚C ambient  
RPM  
50 ˚C ambient  
RPM  
PWM  
LOAD (A)  
Noise (dbA)  
LOAD (A)  
Noise (dbA)  
0%  
5%  
0
3028  
3028  
3028  
3060  
3028  
3028  
3060  
3060  
3028  
3028  
3060  
3028  
3028  
3060  
3060  
3060  
3060  
3420  
3868  
4376  
5040  
35.2  
35.2  
35.2  
35.4  
35.2  
35.2  
35.4  
35.4  
35.2  
35.2  
35.4  
35.2  
35.2  
35.4  
35.4  
35.4  
35.4  
37.4  
39.3  
41.3  
43.9  
0
3180  
3300  
3300  
3360  
3360  
3360  
3360  
3388  
3388  
3540  
3840  
4104  
4408  
4736  
5184  
5728  
6688  
7560  
7584  
7584  
7584  
36.0  
36.7  
36.7  
37.0  
37.0  
37.0  
37.0  
37.2  
37.2  
38.0  
39.2  
40.2  
41.4  
42.7  
44.5  
46.4  
49.5  
51.8  
51.9  
51.9  
51.9  
2.5  
5
2.5  
5
10%  
15%  
20%  
25%  
30%  
35%  
40%  
45%  
50%  
55%  
60%  
65%  
70%  
75%  
80%  
85%  
90%  
95%  
100%  
7.5  
10  
7.5  
10  
12.5  
15  
12.5  
15  
17.5  
20  
17.5  
20  
22.5  
25  
22.5  
25  
27.5  
30  
27.5  
30  
32.5  
35  
32.5  
35  
37.5  
40  
37.5  
40  
42.5  
45  
42.5  
45  
47.5  
50  
47.5  
50  
advancedenergy.com  
9
LCM600  
ACCESSORIES  
PIN 20  
PIN 19  
PIN 3  
PIN 1  
PIN 2  
300 5 mm  
Order kit part number 73-788-001 for control connector interface with .3m wires attached  
PIN 19  
PIN 20  
PIN 3  
PIN 1  
PIN 2  
Order kit part number 73-788-002 for control connector interface with unloaded housing and 20 pins  
MISCELLANEOUS SPECIFICATIONS  
Burn-In  
Quality Assurance  
100% Burn-in at 45 °C, at 80 - 90 % load. Duration of  
burn-in determined by Quality Assurance Procedures.  
Full QAV testing shall be conducted in accordance  
with Artesyn Embedded Power Standards with reports  
available upon request.  
MTBF  
The power supply has a minimum MTBF of 300K hours  
using the Bell core 332, issue 6 specification @ 25 °C  
and 40 °C, ambient, at full load. With the power supply  
installed in a system in a 25 °C ambient environment  
and operating at full load, capacitor life shall be 10 years,  
minimum for ALL electrolytic capacitors contained within  
this power supply. The power supply shall demonstrate a  
MTBF level of > 500,000 hours.  
Warranty  
Artesyn Embedded Power shall warrant the power supply  
to be free of defects in materials and workmanship for a  
minimum period of three years from the date of shipment,  
when operated within specifications. The warranty shall  
be fully transferable to the end owner of the equipment  
powered by the supply.  
10 advancedenergy.com  
ABOUT ADVANCED ENERGY  
Advanced Energy (AE) has devoted more than three  
decades to perfecting power for its global customers. AE  
designs and manufactures highly engineered, precision  
power conversion, measurement and control solutions for  
mission-critical applications and processes.  
Our products enable customer innovation in complex  
applications for a wide range of industries including  
semiconductor equipment, industrial, manufacturing,  
telecommunications, data center computing, and medical.  
With deep applications know-how and responsive service  
and support across the globe, we build collaborative  
partnerships to meet rapid technological developments,  
propel growth for our customers, and innovate the future  
of power.  
For international contact information,  
visit advancedenergy.com.  
Specifications are subject to change without notice. Not responsible  
for errors or omissions. ©2021 Advanced Energy Industries, Inc. All rights  
reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks  
of Advanced Energy Industries, Inc.  
powersales@aei.com (Sales Support)  
productsupport.ep@aei.com (Technical Support)  
+1 888 412 7832  
ENG-LCM600-235-01 1.29  

相关型号:

LCM600L-N-4

AC/DC CONVERTER 12V 600W
ARTESYN

LCM600L-T

AC/DC CONVERTER 12V 600W
ARTESYN

LCM600L-T-4

AC/DC CONVERTER 12V 5V 600W
ARTESYN

LCM600L-T-4-A

AC/DC CONVERTER 12V 600W
ARTESYN

LCM600L-T-A

AC/DC CONVERTER 12V 600W
ARTESYN

LCM600L-T-N-4

AC/DC CONVERTER 12V 600W
ARTESYN

LCM600N

600 Watts Bulk Front End
EMERSON-NETWO

LCM600N-4-A

AC/DC CONVERTER 15V 600W
ARTESYN

LCM600N-A

AC/DC CONVERTER 15V 600W
ARTESYN

LCM600N-N

AC/DC CONVERTER 15V 600W
ARTESYN

LCM600N-N-4

AC/DC CONVERTER 15V 600W
ARTESYN

LCM600N-T

AC/DC CONVERTER 15V 600W
ARTESYN