LCM600L-N-4 [ARTESYN]
AC/DC CONVERTER 12V 600W;型号: | LCM600L-N-4 |
厂家: | ARTESYN TECHNOLOGIES |
描述: | AC/DC CONVERTER 12V 600W |
文件: | 总11页 (文件大小:914K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ARTESYN LCM600
600 Watt Bulk Front End
Advanced Energy's Artesyn LCM600 series of 2U high
distributed power front-end AC-DC power supplies
provides a very cost effective bulk power solution. The series
comprises five models, offering outputs of 12 V, 15 V, 24 V,
36 V or 48 V, together with an optional 5 V standby output.
Each model accepts a universal input of 85–264 Vac and has
a typical full load efficiency of 89%. Carrying industrial and
medical safety approvals, these power supplies can deliver
up to 600 watts and offer versatile bulk power for a wide
variety of industrial, medical, military and process automation
applications.
DATA SHEET
Total Power:
600 W
# of Outputs:
Single
Outputs:
12 to 60 V
Optional 5.0 V standby
SPECIAL FEATURES
COMPLIANCE
600 W output power
Low cost
EMI Class B
EN61000 Immunity
2.4” x 4.5” x 7.5”
SAFETY
7.41 W/cu-in
Industrial/Medical safety
-40 °C to 70 °C with derating
Optional 5 V @ 2 A housekeeping
High efficiency: 89% typical
Variable speed “Smart Fans”
DSP controlled front end
Conformal coat option
UL/CSA
TUV
UL/CSA62368-1
EN62368-1
CB Report
IEC60950-1,
IEC60601-1
CCC
GB4943, GB9254
and GB17625
UL/CSA
TUV
ES60601-1/CSA
C22.2 No. 60601-1
20% adꢀustment range
EN60601-1
Margin programming
OR-ing FET
** LCM600 tested according to the
medical standard IEC 60601-1-2 4th
Edition.
Terminal block input option
©2021 Advanced Energy Industries, Inc.
LCM600
ELECTRICAL SPECIFICATIONS
Input
Input range
85 - 264 Vac (Operating)
115/230 Vac (Nominal) Input through standard IEC connector/
TERMINAL BLOCK
Frequency
47 - 440 Hz, Nominal 50/60
Input fusing
Inrush current
Power factor
Internal 10 A fuses, both lines fused
≤ 25 A peak, either hot or cold start
0.99 typical, meets EN61000-3-2
Harmonics
Meets IEC 1000-3-2 requirements
Input current
Hold up time
Efficiency
8 A RMS max input current, at 100 Vac
20 ms minimum for main O/P, at full rated load
> 89% at full load
Leakage current
< 0.3 mA at 240 Vac
ON/OFF power switch
Power line transient
Isolation
N/A
MOV directly after the fuse
Isolation: PRI-Chassis 2500 Vdc Basic
PRI-SEC 4000 Vac Reinforced 2xMOPP
SEC-Chassis 500 Vdc
LCM600Q Efꢀciency Without the 5 Vsb
92.00
90.00
88.00
86.00
84.00
82.00
80.00
78.00
76.00
100 Vac
230 Vac
25
50
75
100
Loading %
2
advancedenergy.com
LCM600
ELECTRICAL SPECIFICATIONS (CONTINUED)
Output
Output rating
Set point
See ordering information table
0.5%
85 - 264 Vac
85 - 264 Vac
Total regulation range
Main output 2%
5 Vsb 1%
Combined line/load/transient when measured at output terminal
Rated load
600 W maximum
Derate linear to 50% from 50 °C to 70 °C
No loss of regulation
Minimum load
Main output @ 0.0 A
5 Vsb @ 0.0 A
Output noise (PARD)
1% max p-p 50 mV max p-p
Main output
5 Vsb output
Measured with a 0.1 μF Ceramic and 10 μF Tantalum Capacitor on
any output, 20 MHz
Output voltage overshoot
Transient response
< 300 μSec
No overshoot/undershoot outside the regulation band during on
or off cycle
50% load step @ 1 A/μs
Step load valid between 10% to 100% of output rating
Recovery time to within 1% of set point at onset of transient
Max units in parallel
Short circuit protection
Remote sense
Up to 10
Protected, no damage to occur
Bounce mode
Compensation up to 500 mV
Standard per safety requirements
Analog sharing control
Output isolation
Forced load sharing
Overload protection (OCP)
To within 10% of all shared outputs
105% to 125%
120% to 170%
Main output
5 Vsb output
Overvoltage protection (OVP)
125% to 145%
110% to 125%
12 V output
5 Vsb output
Overtemp protection
Fan Fault Protection
10 - 15 °C above safe operating area
Both PFC and output converter monitored
For-N option only. Will shutdown output and DC_OK
ENVIRONMENTAL SPECIFICATIONS
Operating temperature
Storage temperature
Humidity
-40 °C to +70 °C, linear derating to 50% from 50 °C to 70 °C
-40 °C to +85 °C
10 to 90%, non-condensing. Operating. Conformal coat option available
Fan noise
< 45 dBA, 80% load at 30 °C “-N” Low Noise Option < 35 dBA, 80% Load at 30 °C
Altitude
Operating - 16,404.2 feet
Storage - 30,000 feet
Shock
MIL-STD-810F 516.5, Procedure I, VI. Storage
MIL-STD-810F 514.5, Cat. 4, 10. Storage
Vibration
advancedenergy.com
3
LCM600
ORDERING INFORMATION
Current
Nominal Output
Voltage Set
Point
Output
Ripple
Max
Continuous
Power
Combined
Line/Load
Regulation
Model
Set Point
Tolerance
Adjustment
Range
Min
Max
Number*
Output
12 V
P/P (0-50 ˚C)
LCM600L
12 V
15 V
24 V
36 V
48 V
0.5%
0.5%
0.5%
0.5%
0.5%
9.6 - 14.4 V
12.0 - 19.5 V
19.2 - 28.8 V
28.8 - 43.2 V
38.4 - 57.6 V
0 A
0 A
0 A
0 A
0 A
52 A
44 A
120 mV
150 mV
240 mV
240 mV
280 mV
600 W
600 W
600 W
600 W
600 W
2%
2%
2%
2%
2%
LCM600N
LCM600Q
LCM600U
LCM600W
15 V
24 V
27 A
36 V
16.7 A
14 A
48 V
*Note: Add “-T” for terminal block instead of IEC input
Add “-N” for low noise model on 12 V or 24 V models
Add “-4” for 5 V Standby output
Add “-A” will be automatically added to all orders to denote new Aesthetics style chassis unless otherwise specified
Example: a 24 V with terminal block, low noise and standby with new Aesthetics would be LCM600Q-T-N-4-A
PIN ASSIGNMENT
Signals
+Vout
GND
Name Description
Power rail
Pin Number(s)
SK4
Power GND
SK5
Signals
A2
Name Description
EEPROM Address
SK2 Pin Number
1
2
-VPROG
Return connection of external supply for Margin
Programming
A1
EEPROM Address
3
4
-Vsense
Remote Sense Return
ISHARE
Load share voltage
5
A0
EEPROM Address
6
7
SDA1
+VPROG
Serial Data Signal (I2C)
Positive connection of external supply for Margin
Programming
8
SCL1
Serial Clock Signal (I2C)
Remote Sense Positive
5V standby
9
+Vsense
5VSB
10
11
12
13
14
15
16
GND
5V standby Return
5VSB
5V standby
G_DCOK_C
GPIOA6
G_DCOK_E
GND
Global DCOK Collector
EEPROM Write Protect
Global DCOK Emitter (GND)
Return Ground for output signal and I2C
communication
17
G_ACOK_C
INH_EN
Global ACOK Collector
Turn Off Main Output
18
19
20
G_ACOK_E
Global ACOK Emitter (GND)
Note: Mating connector for SK2 is:
LANDWIN: PN 2050S2000 Housing and PN 2053T021V Contact
CIVILUX: PN CI0120SD000 Housing and PN CI01TD21PE0 Contact
JST: PN PHDR-20VS housing and PN: SPHD-001T-P0.5
Signal Output Signal Connectors (SK2)
SK2 Mating Connector: JST Part Number PHDR-20VS;
Contact Pins: JST Part Number SPHD-001T-P0.5
4
advancedenergy.com
LCM600
PIN ASSIGNMENT (CONTINUED)
LED Indicators
Two (2) provided are clearly visible up to a 45 degree offset from vertical with office environment ambient lighting. The
status is reflected in the indicator color.
The DC_OK LED LED is bicolor. It shall light green if the DC output is within specification, and amber if the output falls
out of specification.
The AC_OK LED LED is green if the AC is within specification and off when out of specification. Note: With 5 V standby,
Amber also indicates that PSU is in standby mode/output off.
Control Signals
AC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided.
DC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided.
DC_OK will de-assert when output is loss due to OCP, OVP, OTP, or Fan Fault (for -N option).
PS_INHIBIT/ENABLE Signal 0.0 - 0.5 V contact closure, output OFF
ORDERING INFORMATION
LCMXXXXY
-
A
-
B
-
C
-
###
Case Size
Input Termination
Acoustic Noise
Option Codes
Hardware Code
1-Phase input where XXXX =
600 = 2.4” x 4.5” x 7.5”, 600 W
Blank = IEC connector
T = Terminal Block
Blank = Standard
N = Low Noise Fan
Blank = No Options
Factory Assigned for
Modiefied standards
1 = Conformal Coat
4 = 5 V Standby
5 = Opt 1 + 4
Voltage Code Y =
Code
L
12
15
24
36
48
N
Q
U
W
advancedenergy.com
5
LCM600
MECHANICAL DRAWINGS
(212.2 ref)
190.5 0.5
(18.5)
SEE DETAIL A
SEE DETAIL C (TRIMPOT LOCATION)
GROUND
NEUTRAL
LIVE
DETAIL A
SCALE 1.500
SCREW-MC PHILIP PAN
WITH WASHER M4x8
(8X) MOUNTING LOCATIONS
BOTH SIDES
M4X0.7P THREAD
SEE NOTE 7
BRAND LOGO
SEE DETAIL B
INPUT TERMINAL BLOCK
SEE NOTE 8
(2X)6 0.5
(2X)10.6
50
SK4 & SK5
LED (AC OK)
(2X)182.5 0.5
(2X)177.5 0.5
LED (DC/OK FAIL)
SK2 SIGNAL
CONNECTOR - 20WAY
(2X)10 0.5
VOLTAGE ADJUSTMENT:
CLOCKWISE - INCREASE VOLTAGE
COUNTER CLOCKWISE - DECREASE VOLTAGE
DETAIL C
(TRIMPOT LOCATION)
(4X) MOUNTING LOCATIONS
M4X0.7P THREAD
SEE NOTE 7
DETAIL B
AC INLET VERSION
New Mechanical Reference Drawing:
Weight: 2.84 lbs (1.29 Kg)
Note 7 RECOMMENDED SCREW TORQUE:
M3.5x0.6P = 6-8kgf-cm
MOUNTING LOCATIONS SCREW
PENETRATION DEPTH IS 4.6 mm MAX.
M4.0x0.7P = 8-10kfg-cm
Note 8 INPUT: TERMINAL BLOCK TYPE.
M3.5 SCREW TORQUE VALUE OF 12kgf-cm
USING WIRE GAUGE 22-19 (9.5mm CENTERS)
RECOMMENDED SCREW TORQUE:
M3.5 x 0.6P = 6 - 8kgf-cm
M4.0 x 0.7P = 8 - 10kgf-cm
NOTE: OPTIONAL BARRIER STRIP OUTPUT TERMINAL AVAILABLE
OPTIONAL MOLEX TYPE CONNECTOR OUTPUT AVAILABLE
6
advancedenergy.com
LCM600
MECHANICAL DRAWINGS – TERMINAL BLOCK INPUT
190,5 0,5
SEE DETAIL
A
18,5 REF
SEE DETAIL B (TRIMPOT LOCATION)
GROUND
NUETRAL
LIVE
DETAIL
A
SCALE 8:5
SCREW-MC PHILIP PAN
WITH EXT-T WASHER
M3.5 x P0.6 x 6
INPUT TERMINAL BLOCK
SEE NOTE 8
PROVISION FOR FUTURE
LABEL REQUIREMENTS
PRODUCT LABEL
(8X) MOUNTING LOCATIONS
BOTH SIDES
M4X0.7P THREAD
SEE NOTE 7
LED (DC/OK FAIL)
LED (AC OK)
POS - SK4
NEG - SK5
(2X)6 0,5
(2X)10,6
50
(2X)182,5 0,5
(2X)177,5 0,5
SK2 SIGNAL CONNECTOR - 20WAY
(2X)10 0,5
VOLTAGE ADJUSTMENT:
(4X) MOUNTING LOCATIONS
M4X0.7P THREAD
SEE NOTE 7
CLOCKWISE - INCREASE VOLTAGE
COUNTER CLOCKWISE - DECREASE VOLTAGE
DETAIL B
(TRIMPOT LOCATION)
AIRFLOW DIRECTION
Old Mechanical Reference Drawing:
Weight: 2.84 lbs (1.29 Kg)
Note 7 - RECOMMENDED SCREW TORQUE:
M3.5x0.6P = 6-8kgf-cm
M4.0x0.7P = 8-10kfg-cm
advancedenergy.com
7
LCM600
LOW NOISE VS. NON-LOW NOISE LCM600 MODEL
60.0
58.0
56.0
54.0
52.0
50.0
48.0
46.0
44.0
42.0
40.0
38.0
36.0
34.0
32.0
30.0
25 Deg Ambient
NON-Low noise version
Low noise version
0
2.5
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
32.5
35
37.5
40
42.5
45
47.5
50
LOAD(A)
60.0
58.0
56.0
54.0
52.0
50.0
48.0
46.0
44.0
42.0
40.0
38.0
36.0
34.0
32.0
30.0
50 Deg Ambient
NON-Low noise version
Low noise version
0
2.5
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
32.5
35
37.5
40
42.5
45
47.5
50
LOAD(A)
NON-LOW NOISE VERSION
25 ˚C ambient
RPM
50 ˚C ambient
RPM
LOAD (A)
Fan (V)
Noise (dbA)
Fan (V)
Noise (dbA)
0
6.254
6.257
6.262
6.263
6.242
6.251
6.251
6.226
6.223
6.242
6.253
6.254
6.253
6.264
6.262
6.262
6.262
7.637
8.919
10.068
11.362
3558.0
3559.8
3562.0
3562.0
3528.9
3530.9
3538.3
3538.2
3541.0
3545.1
3553.9
3564.1
3552.2
3559.7
3559.6
3560.8
3559.8
4521.2
5362.2
6139.5
6893.4
40.9
41.0
41.0
41.0
40.5
40.6
40.7
40.7
40.7
40.8
40.9
41.0
40.9
41.0
41.0
41.0
41.0
47.8
49.3
51.0
52.8
6.228
6.228
6.230
6.242
6.242
6.237
6.229
6.205
6.217
6.227
6.234
6.212
6.642
7.893
9.153
11.035
11.605
11.608
11.608
11.608
11.608
3460.9
3460.9
3494.3
3526.6
3526.6
3515.6
3504.9
3482.8
3490.1
3493.8
3504.3
3501.7
3787.4
4652.3
5463.4
6600.2
6993.9
6997.2
6997.2
6997.2
6997.2
39.9
39.9
40.1
40.1
40.1
40.4
40.2
39.4
40.0
40.1
40.2
40.2
44.1
48.0
50.0
52.0
53.2
53.2
53.2
53.2
53.2
2.5
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
32.5
35
37.5
40
42.5
45
47.5
50
8
advancedenergy.com
LCM600
LOW NOISE VERSION
25 ˚C ambient
RPM
50 ˚C ambient
RPM
PWM
LOAD (A)
Noise (dbA)
LOAD (A)
Noise (dbA)
0%
5%
0
3028
3028
3028
3060
3028
3028
3060
3060
3028
3028
3060
3028
3028
3060
3060
3060
3060
3420
3868
4376
5040
35.2
35.2
35.2
35.4
35.2
35.2
35.4
35.4
35.2
35.2
35.4
35.2
35.2
35.4
35.4
35.4
35.4
37.4
39.3
41.3
43.9
0
3180
3300
3300
3360
3360
3360
3360
3388
3388
3540
3840
4104
4408
4736
5184
5728
6688
7560
7584
7584
7584
36.0
36.7
36.7
37.0
37.0
37.0
37.0
37.2
37.2
38.0
39.2
40.2
41.4
42.7
44.5
46.4
49.5
51.8
51.9
51.9
51.9
2.5
5
2.5
5
10%
15%
20%
25%
30%
35%
40%
45%
50%
55%
60%
65%
70%
75%
80%
85%
90%
95%
100%
7.5
10
7.5
10
12.5
15
12.5
15
17.5
20
17.5
20
22.5
25
22.5
25
27.5
30
27.5
30
32.5
35
32.5
35
37.5
40
37.5
40
42.5
45
42.5
45
47.5
50
47.5
50
advancedenergy.com
9
LCM600
ACCESSORIES
PIN 20
PIN 19
PIN 3
PIN 1
PIN 2
300 5 mm
Order kit part number 73-788-001 for control connector interface with .3m wires attached
PIN 19
PIN 20
PIN 3
PIN 1
PIN 2
Order kit part number 73-788-002 for control connector interface with unloaded housing and 20 pins
MISCELLANEOUS SPECIFICATIONS
Burn-In
Quality Assurance
100% Burn-in at 45 °C, at 80 - 90 % load. Duration of
burn-in determined by Quality Assurance Procedures.
Full QAV testing shall be conducted in accordance
with Artesyn Embedded Power Standards with reports
available upon request.
MTBF
The power supply has a minimum MTBF of 300K hours
using the Bell core 332, issue 6 specification @ 25 °C
and 40 °C, ambient, at full load. With the power supply
installed in a system in a 25 °C ambient environment
and operating at full load, capacitor life shall be 10 years,
minimum for ALL electrolytic capacitors contained within
this power supply. The power supply shall demonstrate a
MTBF level of > 500,000 hours.
Warranty
Artesyn Embedded Power shall warrant the power supply
to be free of defects in materials and workmanship for a
minimum period of three years from the date of shipment,
when operated within specifications. The warranty shall
be fully transferable to the end owner of the equipment
powered by the supply.
10 advancedenergy.com
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three
decades to perfecting power for its global customers. AE
designs and manufactures highly engineered, precision
power conversion, measurement and control solutions for
mission-critical applications and processes.
Our products enable customer innovation in complex
applications for a wide range of industries including
semiconductor equipment, industrial, manufacturing,
telecommunications, data center computing, and medical.
With deep applications know-how and responsive service
and support across the globe, we build collaborative
partnerships to meet rapid technological developments,
propel growth for our customers, and innovate the future
of power.
For international contact information,
visit advancedenergy.com.
Specifications are subject to change without notice. Not responsible
for errors or omissions. ©2021 Advanced Energy Industries, Inc. All rights
reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks
of Advanced Energy Industries, Inc.
powersales@aei.com (Sales Support)
productsupport.ep@aei.com (Technical Support)
+1 888 412 7832
ENG-LCM600-235-01 1.29
相关型号:
©2020 ICPDF网 联系我们和版权申明