ACS756  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
Features and Benefits  
Description  
Industry-leading noise performance through proprietary  
amplifier and filter design techniques  
The Allegro ACS756 family of current sensor ICs provides  
economicalandprecisesolutionsforACorDCcurrentsensing  
in industrial, automotive, commercial, and communications  
systems.Thedevicepackageallowsforeasyimplementationby  
the customer. Typical applications include motor control, load  
detection and management, power supplies, and overcurrent  
fault protection.  
Total output error 0.8% at TA= 25°C  
Small package size, with easy mounting capability  
Monolithic Hall IC for high reliability  
Ultra-low power loss:130 μΩ internal conductor resistance  
3 kVRMS minimum isolation voltage from  
pins 1-3 to pins 4-5  
The device consists of a precision, low-offset linear Hall  
circuit with a copper conduction path located near the die.  
Applied current flowing through this copper conduction path  
generates a magnetic field which the Hall IC converts into a  
proportionalvoltage.Deviceaccuracyisoptimizedthroughthe  
close proximity of the magnetic signal to the Hall transducer.  
A precise, proportional voltage is provided by the low-offset,  
chopper-stabilized BiCMOS Hall IC, which is programmed  
for accuracy at the factory.  
3.0 to 5.0 V, single supply operation  
3 μs output rise time in response to step input current  
20 or 40 mV/A output sensitivity  
Output voltage proportional to AC or DC currents  
Factory-trimmed for accuracy  
Extremely stable output offset voltage  
Nearly zero magnetic hysteresis  
TÜV America  
Certificate Number:  
U8V 09 05 54214 021  
Theoutputofthedevicehasapositiveslope(>VCC/2)whenan  
increasingcurrentflowsthroughtheprimarycopperconduction  
path (from terminal 4 to terminal 5), which is the path used  
forcurrentsampling.Theinternalresistanceofthisconductive  
path is 130 μΩ typical, providing low power loss.  
Package: 5 pin package (suffix PFF)  
The thickness of the copper conductor allows survival of the  
device at up to 5× overcurrent conditions. The terminals of the  
1
Continued on the next page…  
Additional leadforms available for qualifying volumes  
Typical Application  
+5 V  
1
2
4
5
VCC  
IP+  
IP–  
CBYP  
0.1 μF  
ACS756  
IP  
GND  
CF  
3
VIOUT  
VOUT  
RF  
Application 1. The ACS756 outputs an analog signal, VOUT, that  
varies linearly with the uni- or bi-directional AC or DC primary  
sampled current, IP, within the range specified. CF is for optimal  
noise management, with values that depend on the application.  
ACS756-DS, Rev. 6  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
Description (continued)  
conductive path are electrically isolated from the signal leads (pins The device is fully calibrated prior to shipment from the factory.  
1 through 3). This allows the ACS756 family of sensor ICs to be TheACS75x family is lead (Pb) free.All leads are plated with 100%  
used in applications requiring electrical isolation without the use of matte tin, and there is no Pb inside the package. The heavy gauge  
opto-isolators or other costly isolation techniques.  
leadframe is made of oxygen-free copper.  
Selection Guide  
Primary Sampled  
Current , IP  
(A)  
TOP  
Part Number1  
(°C)  
Packing2  
ACS756SCA-050B-PFF-T  
ACS756SCA-100B-PFF-T  
ACS756KCA-050B-PFF-T  
–20 to 85  
–20 to 85  
–40 to 125  
±50  
±100  
±50  
34 per tube  
1Additional leadform options available for qualified volumes  
2Contact Allegro for additional packing options.  
Absolute Maximum Ratings  
Characteristic  
Symbol  
VCC  
Notes  
Rating  
8
Units  
Forward Supply Voltage  
V
V
V
V
Reverse Supply Voltage  
Forward Output Voltage  
Reverse Output Voltage  
VRCC  
–0.5  
28  
VIOUT  
VRIOUT  
–0.5  
Voltage applied between pins 1-3 and 4-5;  
tested at 3000 VAC for 1 minute according to  
UL standard 60950-1  
Working Voltage for Reinforced Isolation  
Working Voltage for Basic Isolation  
VWORKING-R  
353  
500  
VDC/Vpk  
VDC/Vpk  
Voltage applied between pins 1-3 and 4-5;  
tested at 3000 VAC for 1 minute according to  
UL standard 60950-1  
VWORKING-B  
Output Source Current  
Output Sink Current  
IOUT(Source)  
IOUT(Sink)  
VIOUT to GND  
VCC to VIOUT  
Range K  
3
mA  
mA  
ºC  
1
–40 to 125  
–20 to 85  
165  
Nominal Operating Ambient Temperature  
TOP  
Range S  
ºC  
Maximum Junction  
TJ(max)  
Tstg  
ºC  
Storage Temperature  
–65 to 165  
ºC  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
2
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
Functional Block Diagram  
+5 V  
VCC  
IP+  
To all subcircuits  
VIOUT  
Amp  
Out  
0.1 μF  
Temperature  
Coefficient  
Gain  
Offset  
Trim Control  
GND  
IP–  
Pin-out Diagram  
IP+  
4
3
2
1
VIOUT  
GND  
VCC  
IP–  
5
Terminal List Table  
Number  
Name  
VCC  
GND  
VIOUT  
IP+  
Description  
1
2
3
4
5
Device power supply terminal  
Signal ground terminal  
Analog output signal  
Terminal for current being sampled  
Terminal for current being sampled  
IP–  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
3
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
COMMON OPERATING CHARACTERISTICS1 over full range of TOP, and VCC = 5 V, unless otherwise specified  
Characteristic  
Symbol  
Test Conditions  
Min.  
Typ.  
5.0  
10  
Max.  
5.5  
14  
Units  
V
Supply Voltage2  
VCC  
3
Supply Current  
ICC  
VCC = 5.0 V, output open  
mA  
μs  
Power On Time  
tPO  
TA = 25°C  
35  
Rise Time  
tr  
IP = three-quarter scale of IP+, TA = 25°C, COUT = 0.47 nF  
3
μs  
Internal Bandwidth3  
Output Load Resistance  
Output Load Capacitance  
Primary Conductor Resistance  
Symmetry  
BWi  
–3 dB; IP is 10 A peak-to-peak; 100 pF from VIOUT to GND  
120  
kHz  
kΩ  
nF  
RLOAD(MIN)  
CLOAD(MAX)  
RPRIMARY  
ESYM  
VIOUT to GND  
VIOUT to GND  
TA = 25°C  
4.7  
10  
130  
100  
μꢀ  
%
Over half-scale of Ip  
98.5  
101.5  
Bidirectional 0 A Output  
Magnetic Offset Error  
Ratiometry  
VOUT(QBI)  
IERROM  
VRAT  
IP = 0 A, TA = 25°C  
VCC/2  
±0.23  
100  
1
V
A
IP = 0 A, after excursion of 100 A  
VCC = 4.5 to 5.5 V  
%
μs  
Propagation Time  
tPROP  
TA = 25°C, COUT = 100 pF,  
1Device is factory-trimmed at 5 V, for optimal accuracy.  
2Devices are programmed for maximum accuracy at 5.0 V VCC levels. The device contains ratiometry circuits that accurately alter the 0 A Output Volt-  
age and Sensitivity level of the device in proportion to the applied VCC level. However, as a result of minor nonlinearities in the ratiometry circuit ad-  
ditional output error will result when VCC varies from the 5 V VCC level. Customers that plan to operate the device from a 3.3 V regulated supply should  
contact their local Allegro sales representative regarding expected device accuracy levels under these bias conditions.  
3Guaranteed by design.  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
4
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
X050 PERFORMANCE CHARACTERISTICS over Range K1: TOP = –40°C to 125°C, VCC= 5 V, unless otherwise specified  
Characteristic  
Symbol  
Test Conditions  
Min.  
–50  
Typ.  
Max.  
50  
Units  
A
Primary Sampled Current  
IP  
SensTA  
Half scale of IP applied for 5 ms, TA = 25°C  
40  
mV/A  
mV/A  
mV  
%
Sensitivity  
Noise2  
SensTOP Half scale of IP applied for 5 ms  
37.2  
42.8  
VNOISE  
ELIN(HT)  
ELIN(LT)  
VOE(TA)  
TA= 25°C, 10 nF on VIOUT pin to GND  
10  
Up to full scale of IP, IP applied for 5 ms, TOP = 25°C to 125°C  
Up to full scale of IP, IP applied for 5 ms, TOP = –40°C to 25°C  
IP = 0 A, TA = 25°C  
– 1  
– 1.8  
1
Nonlinearity  
1.8  
%
±2  
mV  
mV  
mV  
%
Electrical Offset Voltage3  
Total Output Error4  
VOE(TOP)HT IP = 0 A, TOP = 25°C to 125°C  
–30  
–60  
–7.5  
–7.5  
30  
60  
7.5  
7.5  
VOE(TOP)LT IP = 0 A, TOP = –40°C to 25°C  
ETOT(HT) Over full scale of IP, IP applied for 5 ms, TOP = 25°C to 125°C  
ETOT(LT) Over full scale of IP, IP applied for 5 ms, TOP = –40°C to 25°C  
%
1Device may be operated at higher primary current levels, IP, and ambient temperatures, TOP, provided that the Maximum Junction Temperature,  
TJ(max), is not exceeded.  
26σ noise voltage.  
3VOE(TOP) drift is referred to ideal VOE = 2.5 V at 0 A.  
4Percentage of IP, with IP = 25 A. Output filtered.  
X050 PERFORMANCE CHARACTERISTICS over Range S1: TOP = –20°C to 85°C, VCC= 5 V, unless otherwise specified  
Characteristic  
Symbol  
Test Conditions  
Min.  
–50  
Typ.  
Max.  
50  
Units  
A
Primary Sampled Current  
IP  
SensTA  
Half scale of IP applied for 5 ms, TA = 25°C  
40  
mV/A  
mV/A  
mV  
%
Sensitivity  
Noise2  
SensTOP Half scale of IP applied for 5 ms  
38.3  
41.7  
VNOISE  
ELIN(HT)  
ELIN(LT)  
VOE(TA)  
TA= 25°C, 10 nF on VIOUT pin to GND  
10  
Up to full scale of IP, IP applied for 5 ms, TOP = 25°C to 85°C  
Up to full scale of IP, IP applied for 5 ms, TOP = –20°C to 25°C  
IP = 0 A, TA = 25°C  
– 1  
– 1  
1
Nonlinearity  
1
%
±2  
mV  
mV  
mV  
%
Electrical Offset Voltage3  
Total Output Error4  
VOE(TOP)HT IP = 0 A, TOP = 25°C to 85°C  
–30  
–30  
–5  
30  
30  
5
VOE(TOP)LT IP = 0 A, TOP = –20°C to 25°C  
ETOT(HT) Over full scale of IP, IP applied for 5 ms, TOP = 25°C to 85°C  
ETOT(LT) Over full scale of IP, IP applied for 5 ms, TOP = –20°C to 25°C  
–5  
5
%
1Device may be operated at higher primary current levels, IP, and ambient temperatures, TOP, provided that the Maximum Junction Temperature,  
TJ(max), is not exceeded.  
26σ noise voltage.  
3VOE(TOP) drift is referred to ideal VOE = 2.5 V at 0 A.  
4Percentage of IP, with IP = 25 A. Output filtered.  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
5
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
X100 PERFORMANCE CHARACTERISTICS over Range S1: TOP = –20°C to 85°C, VCC= 5 V, unless otherwise specified  
Characteristic  
Symbol  
Test Conditions  
Min.  
–100  
Typ.  
Max.  
100  
Units  
A
Primary Sampled Current  
IP  
SensTA  
Half scale of IP applied for 5 ms, TA = 25°C  
20  
mV/A  
mV/A  
mV  
%
Sensitivity  
Noise2  
SensTOP Half scale of IP applied for 5 ms  
18.2  
21.8  
VNOISE  
ELIN(HT)  
ELIN(LT)  
VOE(TA)  
TA= 25°C, 10 nF on VIOUT pin to GND  
6
Up to full scale of IP, IP applied for 5 ms, TOP = 25°C to 85°C  
Up to full scale of IP, IP applied for 5 ms, TOP = –20°C to 25°C  
IP = 0 A, TA = 25°C  
– 1.75  
– 1  
1.75  
1
Nonlinearity  
%
±2  
mV  
mV  
mV  
%
Electrical Offset Voltage3  
Total Output Error4  
VOE(TOP)HT IP = 0 A, TOP = 25°C to 85°C  
–30  
–30  
–8  
30  
30  
8
VOE(TOP)LT IP = 0 A, TOP = –20°C to 25°C  
ETOT(HT) Over full scale of IP, IP applied for 5 ms, TOP = 25°C to 85°C  
ETOT(LT) Over full scale of IP, IP applied for 5 ms, TOP = –20°C to 25°C  
–7  
7
%
1Device may be operated at higher primary current levels, IP, and ambient temperatures, TOP, provided that the Maximum Junction Temperature,  
TJ(max), is not exceeded.  
26σ noise voltage.  
3VOE(TOP) drift is referred to ideal VOE = 2.5 V at 0 A.  
4Percentage of IP, with IP = 25 A. Output filtered.  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
6
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
Definitions of Accuracy Characteristics  
Sensitivity (Sens). The change in device output in response to a  
1A change through the primary conductor. The sensitivity is the  
product of the magnetic circuit sensitivity (G/A) and the linear  
IC amplifier gain (mV/G). The linear IC amplifier gain is pro-  
grammed at the factory to optimize the sensitivity (mV/A) for the  
half-scale current of the device.  
The ratiometric change (%) in the quiescent voltage output is  
defined as:  
VIOUTQ(V  
VIOUTQ(5V)  
)
CC  
$VIOUTQ($V)  
s ꢀꢁꢁ%  
=
VCC  
5 V  
and the ratiometric change (%) in sensitivity is defined as:  
Sens(V  
Sens(Vꢂ  
CC  
Noise (VNOISE). The noise floor is derived from the thermal and  
shot noise observed in Hall elements. Dividing the noise (mV)  
by the sensitivity (mV/A) provides the smallest current that the  
device is able to resolve.  
$Sens($Vꢂ  
s ꢀꢁꢁ%  
=
VCC  
5 V  
Quiescent output voltage (VIOUT(Q)). The output of the device  
when the primary current is zero. For a unipolar supply voltage,  
it nominally remains at VCC 2. Thus, VCC = 5 V translates into  
IOUT(Q) = 2.5 V. Variation in VOUT(Q) can be attributed to the res-  
olution of the Allegro linear IC quiescent voltage trim, magnetic  
hysteresis, and thermal drift.  
Nonlinearity (ELIN). The degree to which the voltage output  
from the IC varies in direct proportion to the primary current  
through its half-scale amplitude. Nonlinearity in the output can be  
attributed to the saturation of the flux concentrator approaching  
the half-scale current. The following equation is used to derive  
the linearity:  
V
Electrical offset voltage (VOE). The deviation of the device out-  
put from its ideal quiescent value of VCC 2 due to nonmagnetic  
causes.  
V
VIOUT(Q)  
Δ gain × % sat (  
IOUT_half-scale amperes  
2 (VIOUT_quarter-scale amperes VIOUT(Q)  
100  
1–  
{
[
) [ {  
Magnetic offset error (IERROM). The magnetic offset is due to  
the residual magnetism (remnant field) of the core material. The  
magnetic offset error is highest when the magnetic circuit has  
been saturated, usually when the device has been subjected to a  
full-scale or high-current overload condition. The magnetic offset  
is largely dependent on the material used as a flux concentrator.  
The larger magnetic offsets are observed at the lower operating  
temperatures.  
)
where  
gain = the gain variation as a function of temperature  
changes from 25ºC,  
% sat = the percentage of saturation of the flux concentra-  
tor, which becomes significant as the current being sampled  
approaches half-scale ±IP , and  
Total Output Error (ETOT). The maximum deviation of the  
actual output from its ideal value, also referred to as accuracy,  
illustrated graphically in the output voltage versus current chart  
on the following page.  
V
IOUT_half-scale amperes = the output voltage (V) when the  
sampled current approximates half-scale ±IP .  
Symmetry (ESYM). The degree to which the absolute voltage  
output from the IC varies in proportion to either a positive or  
negative half-scale primary current. The following equation is  
used to derive symmetry:  
ETOT is divided into four areas:  
 0 A at 25°C. Accuracy at the zero current flow at 25°C, with-  
out the effects of temperature.  
VIOUT_+ half-scale amperes VIOUT(Q)  
 0 A over Δ temperature. Accuracy at the zero current flow  
100  
VIOUT(Q) VIOUT_–half-scale amperes  
including temperature effects.  
 Half-scale current at 25°C. Accuracy at the the half-scale current  
at 25°C, without the effects of temperature.  
Ratiometry. The device features a ratiometric output. This  
means that the quiescent voltage output, VIOUTQ, and the mag-  
netic sensitivity, Sens, are proportional to the supply voltage, VCC  
 Half-scale current over Δ temperature. Accuracy at the half-  
.
scale current flow including temperature effects.  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
7
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
Definitions of Dynamic Response Characteristics  
Power-On Time (tPO). When the supply is ramped to its operat-  
ing voltage, the device requires a finite time to power its internal  
components before responding to an input magnetic field.  
Power-On Time, tPO , is defined as the time it takes for the output  
voltage to settle within ±10% of its steady state value under an  
applied magnetic field, after the power supply has reached its  
minimum specified operating voltage, VCC(min), as shown in the  
chart at right.  
Rise time (tr). The time interval between a) when the device  
reaches 10% of its full scale value, and b) when it reaches 90%  
of its full scale value. The rise time to a step response is used to  
derive the bandwidth of the device, in which ƒ(–3 dB) = 0.35/tr.  
Both tr and tRESPONSE are detrimentally affected by eddy current  
losses observed in the conductive IC ground plane.  
Primary Current  
I (%)  
90  
Output Voltage versus Sampled Current  
Total Output Error at 0 A and at Half-Scale Current  
Transducer Output  
10  
0
t
Rise Time, t  
r
Increasing VIOUT(V)  
Accuracy  
Over $Temp erature  
Accuracy  
25°C Only  
Average  
V
IOUT  
Propagation delay (tPROP). The time required for the device  
output to reflect a change in the primary current signal. Propaga-  
tion delay is attributed to inductive loading within the linear IC  
package, as well as in the inductive loop formed by the primary  
conductor geometry. Propagation delay can be considered as a  
fixed time offset and may be compensated.  
Accuracy  
Over $Temp erature  
Accuracy  
25°C Only  
IP(min)  
–IP (A)  
+IP (A)  
Half Scale  
IP(max)  
Primary Current  
I (%)  
90  
0 A  
Transducer Output  
Accuracy  
25°C Only  
0
t
Propagation Time, tPROP  
Accuracy  
Over $Temp erature  
Decreasing VIOUT(V)  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
8
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
Chopper Stabilization Technique  
Chopper Stabilization is an innovative circuit technique that is  
This technique is made possible through the use of a BiCMOS  
used to minimize the offset voltage of a Hall element and an asso- process that allows the use of low-offset and low-noise amplifiers  
ciated on-chip amplifier. Allegro patented a Chopper Stabiliza-  
tion technique that nearly eliminates Hall IC output drift induced  
by temperature or package stress effects. This offset reduction  
technique is based on a signal modulation-demodulation process.  
Modulation is used to separate the undesired DC offset signal  
from the magnetically induced signal in the frequency domain.  
Then, using a low-pass filter, the modulated DC offset is sup-  
pressed while the magnetically induced signal passes through  
the filter. As a result of this chopper stabilization approach, the  
output voltage from the Hall IC is desensitized to the effects  
of temperature and mechanical stress. This technique produces  
devices that have an extremely stable Electrical Offset Voltage,  
are immune to thermal stress, and have precise recoverability  
after temperature cycling.  
in combination with high-density logic integration and sample  
and hold circuits.  
Regulator  
Clock/Logic  
Low-Pass  
Filter  
Hall Element  
Amp  
Concept of Chopper Stabilization Technique  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
9
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
Package CA, 5-pin package, leadform PFF  
0.5  
R1  
R3  
0.5  
B
14.0±0.2  
4
R2  
1.50±0.10  
3.0±0.2  
4.0±0.2  
5
4
21.4  
3
1º±2°  
A
3.5±0.2  
0.8  
1.5  
17.5±0.2  
13.00±0.10  
1.91  
PCB Layout Reference View  
B
Branded  
Face  
4.40±0.10  
2.9±0.2  
NNNNNNN  
TTT - AAA  
5º±5°  
+0.060  
–0.030  
1
2
3
0.381  
10.00±0.10  
3.5±0.2  
LLLLLLL  
YYWW  
1
7.00±0.10  
Standard Branding Reference View  
C
N = Device part number  
T = Temperature code  
A = Amperage range  
L = Lot number  
Y = Last two digits of year of manufacture  
W = Week of manufacture  
= Supplier emblem  
0.51±0.10  
1.9±0.2  
For Reference Only; not for tooling use (reference DWG-9111, DWG-9110)  
Dimensions in millimeters  
Dimensions exclusive of mold flash, gate burrs, and dambar protrusions  
Exact case and lead configuration at supplier discretion within limits shown  
A Dambar removal intrusion  
Perimeter through-holes recommended  
B
C
Branding scale and appearance at supplier discretion  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
10  
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  
Fully Integrated, Hall Effect-Based Linear Current Sensor IC  
with 3 kVRMS Voltage Isolation and a Low-Resistance Current Conductor  
ACS756  
Revision History  
Revision  
Revision Date  
Description of Revision  
Augment VCC specification  
Rev. 6  
March 25, 2011  
Copyright ©2006-2011, Allegro MicroSystems, Inc.  
The products described herein are protected by U.S. patents: 6,781,359; and 7,265,531.  
Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the detail specifications as may be required to per-  
mit improvements in the performance, reliability, or manufacturability of its products. Before placing an order, the user is cautioned to verify that the  
information being relied upon is current.  
Allegro’s products are not to be used in life support devices or systems, if a failure of an Allegro product can reasonably be expected to cause the  
failure of that life support device or system, or to affect the safety or effectiveness of that device or system.  
The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no responsibility for its use;  
nor for any infringement of patents or other rights of third parties which may result from its use.  
For the latest version of this document, visit our website:  
www.allegromicro.com  
Allegro MicroSystems, Inc.  
115 Northeast Cutoff  
11  
Worcester, Massachusetts 01615-0036 U.S.A.  
1.508.853.5000; www.allegromicro.com  

相关型号:

ACS756KCA-050B-PFF-T

The Allegro ACS756 family of current sensor ICs provides economical and precise solutions for AC or DC current sensing in industrial, automotive, commercial, and communications systems.
ALLEGRO

ACS756SCA-050B-PFF-T

The Allegro ACS756 family of current sensor ICs provides economical and precise solutions for AC or DC current sensing in industrial, automotive, commercial, and communications systems.
ALLEGRO

ACS756SCA-100B-PFF-T

The Allegro ACS756 family of current sensor ICs provides economical and precise solutions for AC or DC current sensing in industrial, automotive, commercial, and communications systems.
ALLEGRO

ACS756SCB-100B-PSF-T

Analog Circuit,
ALLEGRO

ACS758

Thermally Enhanced, Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 100 Current Conductor
ALLEGRO

ACS758ECB-200B-PFF-T

Thermally Enhanced, Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 100 μΩ Current Conductor
ALLEGRO

ACS758ECB-200B-PSS-T

Thermally Enhanced, Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 100 μΩ Current Conductor
ALLEGRO

ACS758ECB-200U-PFF-T

The Allegro ACS758 family of current sensor ICs provides economical and precise solutions for AC or DC current sensing.
ALLEGRO

ACS758KCB-150B-PFF-T

Thermally Enhanced, Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 100 μΩ Current Conductor
ALLEGRO

ACS758KCB-150B-PSS-T

Thermally Enhanced, Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 100 μΩ Current Conductor
ALLEGRO

ACS758KCB-150U-PFF-T

The Allegro ACS758 family of current sensor ICs provides economical and precise solutions for AC or DC current sensing.
ALLEGRO

ACS758LCB-050B-PFF-T

Thermally Enhanced, Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 100 μΩ Current Conductor
ALLEGRO