ADE7755ARS [ADI]
Energy Metering IC with Pulse Output; 电能计量IC,具有脉冲输出型号: | ADE7755ARS |
厂家: | ADI |
描述: | Energy Metering IC with Pulse Output |
文件: | 总16页 (文件大小:328K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Energy Metering IC
with Pulse Output
a
ADE7755*
The ADE7755 is a high accuracy electrical energy measurement
IC. The part specifications surpass the accuracy requirements as
quoted in the IEC1036 standard. See Analog Devices’ Appli-
cation Note AN-559 for a description of an IEC1036 watt-hour
meter reference design based on the AD7755.
FEATURES
High Accuracy, Surpasses 50 Hz/60 Hz IEC 687/1036
Less than 0.1% Error over a Dynamic Range of
500 to 1
The ADE7755 Supplies Average Real Power on the
Frequency Outputs F1 and F2
The High-Frequency Output CF Is Intended for
Calibration and Supplies Instantaneous Real Power
Pin Compatible with AD7755 with Synchronous CF and
F1/F2 Outputs
The only analog circuitry used in the ADE7755 is in the ADCs
and reference circuit. All other signal processing (e.g., multipli-
cation and filtering) is carried out in the digital domain. This
approach provides superior stability and accuracy over extremes
in environmental conditions and over time.
The Logic Output REVP Can Be Used to Indicate a
Potential Miswiring or Negative Power
Direct Drive for Electromechanical Counters and
Two Phase Stepper Motors (F1 and F2)
A PGA in the Current Channel Allows the Use of Small
Values of Shunt and Burden Resistance
Proprietary ADCs and DSP Provide High Accuracy over
Large Variations in Environmental Conditions and
Time
The ADE7755 supplies average real power information on the
low-frequency outputs F1 and F2. These logic outputs may be
used to directly drive an electromechanical counter or interface
to an MCU. The CF logic output gives instantaneous real power
information. This output is intended to be used for calibration
purposes or for interfacing to an MCU.
The ADE7755 includes a power supply monitoring circuit on the
AVDD supply pin. The ADE7755 will remain in a reset condition
until the supply voltage on AVDD reaches 4 V. If the supply falls
below 4 V, the ADE7755 will also be reset and no pulses will be
issued on F1, F2, and CF.
On-Chip Power Supply Monitoring
On-Chip Creep Protection (No Load Threshold)
On-Chip Reference 2.5 V ꢃ 8% (30 ppm/ꢄC Typical)
with External Overdrive Capability
Single 5 V Supply, Low Power (15 mW Typical)
Low Cost CMOS Process
Internal phase matching circuitry ensures that the voltage and
current channels are phase matched whether the HPF in Chan-
nel 1 is on or off. An internal no-load threshold ensures that the
ADE7755 does not exhibit any creep when there is no load.
GENERAL DESCRIPTION
The ADE7755 is pin compatible with the AD7755. The only
difference between the ADE7755 and the AD7755 is that the
ADE7755 features a synchronous CF and F1/F2 outputs under
all load conditions.
The ADE7755 is available in a 24-lead SSOP package.
FUNCTIONAL BLOCK DIAGRAM
AV
DD
DV
G0 G1
AGND
AC/DC
DGND
DD
ADE7755
POWER
SUPPLY MONITOR
PHASE
SIGNAL
CORRECTION
PROCESSING
BLOCK
...110101...
V1P
V1N
ADC
ꢂ
PGA
ꢁ1, ꢁ2, ꢁ8, ꢁ16
HPF
LPF
MULTIPLIER
...11011001...
V2P
V2N
ADC
DIGITAL-TO-FREQUENCY
CONVERTER
RESET
4kꢀ
2.5V
REFERENCE
CLKIN CLKOUT
S0
REVP
F1
REF
IN/OUT
CF
SCF
S1
F2
*U.S. Patents 5,745,323, 5,760,617, 5,862,069, and 5,872,469.
REV. 0
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, norforanyinfringementsofpatentsorotherrightsofthirdpartiesthat
may result from its use. No license is granted by implication or otherwise
under any patent or patent rights of Analog Devices.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
Fax: 781/326-8703
www.analog.com
© Analog Devices, Inc., 2002
(AVDD = DVDD = 5 V ꢃ 5%, AGND = DGND = 0 V, On-Chip Reference,
CLKIN = 3.58 MHz, TMIN to TMAX = –40ꢄC to +85ꢄC.)
ADE7755–SPECIFICATIONS
Parameter
Specifications
Unit
Test Conditions/Comments
ACCURACY1, 2
Measurement Error1 on Channel 1
Gain = 1
Gain = 2
Channel 2 with Full-Scale Signal (±660 mV), 25∞C
Over a Dynamic Range 500 to 1
Over a Dynamic Range 500 to 1
Over a Dynamic Range 500 to 1
Over a Dynamic Range 500 to 1
0.1
0.1
0.1
0.1
% Reading typ
% Reading typ
% Reading typ
% Reading typ
Gain = 8
Gain = 16
Phase Error1 Between Channels
V1 Phase Lead 37∞
(PF = 0.8 Capacitive)
V1 Phase Lag 60∞
Line Frequency = 45 Hz to 65 Hz
±0.1
±0.1
0.2
Degrees(∞) max AC/DC = 0 and AC/DC = 1
Degrees(∞) max AC/DC = 0 and AC/DC = 1
(PF = 0.5 Inductive)
AC Power Supply Rejection1
Output Frequency Variation (CF)
AC/DC = 1, S0 = S1 = 1, G0 = G1 = 0
% Reading typ
V1 = 100 mV rms, V2 = 100 mV rms, @ 50 Hz
Ripple on AVDD of 200 mV rms @ 100 Hz
AC/DC = 1, S0 = S1 = 1, G0 = G1 = 0
V1 = 100 mV rms, V2 = 100 mV rms,
AVDD = DVDD = 5 V ± 250 mV
DC Power Supply Rejection1
Output Frequency Variation (CF)
±0.3
% Reading typ
ANALOG INPUTS
Maximum Signal Levels
Input Impedance (DC)
Bandwidth (–3 dB)
ADC Offset Error1, 2
Gain Error1
See Analog Inputs section
V1P, V1N, V2N, and V2P to AGND
CLKIN = 3.58 MHz
CLKIN/256, CLKIN = 3.58 MHz
Gain = 1, See Terminology and Performance Graphs
External 2.5 V Reference, Gain = 1
V1 = 470 mV dc, V2 = 660 mV dc
External 2.5 V Reference
±1
390
14
±25
±7
V max
kW min
kHz typ
mV max
% Ideal typ
Gain Error Match1
±0.2
% Ideal typ
REFERENCE INPUT
REFIN/OUT Input Voltage Range
2.7
2.3
3.2
10
V max
V min
kW min
pF max
2.5 V + 8%
2.5 V – 8%
Input Impedance
Input Capacitance
ON-CHIP REFERENCE
Reference Error
Temperature Coefficient
Nominal 2.5 V
±200
±30
mV max
ppm/∞C typ
CLKIN
Note All Specifications for CLKIN of 3.58 MHz
Input Clock Frequency
4
1
MHz max
MHz min
LOGIC INPUTS3
SCF, S0, S1, AC/DC,
RESET, G0, and G1
Input High Voltage, VINH
Input Low Voltage, VINL
Input Current, IIN
2.4
0.8
±3
10
V min
DVDD = 5 V ± 5%
V max
mA max
pF max
DVDD = 5 V ± 5%
Typically 10 nA, VIN = 0 V to DVDD
Input Capacitance, CIN
LOGIC OUTPUTS3
F1 and F2
Output High Voltage, VOH
ISOURCE = 10 mA
DVDD = 5 V
ISINK = 10 mA
DVDD = 5 V
4.5
0.5
V min
V max
Output Low Voltage, VOL
CF and REVP
Output High Voltage, VOH
ISOURCE = 5 mA
DVDD = 5 V
ISINK = 5 mA
DVDD = 5 V
4
V min
V max
Output Low Voltage, VOL
0.5
REV. 0
–2–
ADE7755
Parameter
Specifications
Unit
Test Conditions/Comments
POWER SUPPLY
AVDD
For Specified Performance
5 V – 5%
5 V + 5%
5 V – 5%
5 V + 5%
Typically 2 mA
Typically 1.5 mA
4.75
5.25
4.75
5.25
3
V min
V max
V min
V max
mA max
mA max
DVDD
AIDD
DIDD
2.5
NOTES
1See Terminology section for explanation of specifications.
2See Plots in Typical Performance Graphs.
3Sample tested during initial release and after any redesign or process change that may affect this parameter.
Specifications subject to change without notice.
(AVDD = DVDD = 5 V ꢃ 5%, AGND = DGND = 0 V, On-Chip Reference, CLKIN = 3.58 MHz, TMIN to
TMAX = –40ꢄC to +85ꢄC.)
TIMING CHARACTERISTICS1, 2
Parameter
Specifications
Unit
Test Conditions/Comments
3
t1
t2
275
See Table III
1/2 t2
ms
sec
sec
ms
sec
sec
F1 and F2 Pulsewidth (Logic Low)
Output Pulse Period. See Transfer Function section.
Time between F1 Falling Edge and F2 Falling Edge
CF Pulsewidth (Logic High)
CF Pulse Period. See Transfer Function section.
Minimum Time between F1 and F2 Pulse
t33, 4
t4
t5
t6
90
See Table IV
CLKIN/4
NOTES
1Sample tested during initial release and after any redesign or process change that may affect this parameter.
2See Figure 1.
3The pulsewidths of F1, F2, and CF are not fixed for higher output frequencies. See Frequency Outputs section.
4The CF pulse is always 18 ms in the high-frequency mode. See Frequency Outputs section and Table IV.
Specifications subject to change without notice.
ABSOLUTE MAXIMUM RATINGS*
(TA = 25∞C unless otherwise noted.)
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . 150∞C
24-Lead SSOP, Power Dissipation . . . . . . . . . . . . . . 450 mW
AVDD to AGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7 V
DVDD to DGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7 V
DVDD to AVDD . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +0.3 V
Analog Input Voltage to AGND
qJA Thermal Impedance . . . . . . . . . . . . . . . . . . . . 112∞C/W
Lead Temperature, Soldering
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . 215∞C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . 220∞C
V1P, V1N, V2P, and V2N . . . . . . . . . . . . . . . –6 V to +6 V
Reference Input Voltage to AGND . . –0.3 V to AVDD + 0.3 V
Digital Input Voltage to DGND . . . –0.3 V to DVDD + 0.3 V
Digital Output Voltage to DGND . . –0.3 V to DVDD + 0.3 V
Operating Temperature Range
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . –40∞C to +85∞C
Storage Temperature Range . . . . . . . . . . . . –65∞C to +150∞C
ORDERING GUIDE
Model
Package Description
Package Options
ADE7755ARS
Shrink Small Outline Package
RS-24
ADE7755ARSRL
ADE7755AN-REF
Shrink Small Outline Package in Reel
ADE7755 Reference Design PCB (See AN-559)
RSRL-24
EVAL-ADE7755EB ADE7755 Evaluation Board
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the ADE7755 features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. 0
–3–
ADE7755
t1
F1
.t6
.t2
F2
.t3
.t5
t4
CF
Figure 1. Timing Diagram for Frequency Outputs
PIN CONFIGURATION
1
2
24
23
22
21
20
19
18
17
16
15
14
13
DV
DD
F1
F2
AC/DC
AV
3
CF
DD
4
DGND
REVP
NC
NC
V1P
5
ADE7755
6
V1N
TOP VIEW
(Not to Scale)
7
CLKOUT
CLKIN
G0
V2N
8
V2P
9
RESET
10
11
12
G1
REF
IN/OUT
AGND
S0
S1
SCF
NC = NO CONNECT
REV. 0
–4–
ADE7755
PIN FUNCTION DESCRIPTIONS
Pin No.
Mnemonic
Description
1
DVDD
Digital Power Supply. This pin provides the supply voltage for the digital circuitry in the ADE7755.
The supply voltage should be maintained at 5 V ± 5% for specified operation. This pin should be
decoupled with a 10 mF capacitor in parallel with a ceramic 100 nF capacitor.
2
3
AC/DC
High-Pass Filter Select. This logic input is used to enable the HPF in Channel 1 (Current Channel).
A logic one on this pin enables the HPF. The associated phase response of this filter has been inter-
nally compensated over a frequency range of 45 Hz to 1 kHz. The HPF filter should be enabled in
power metering applications.
Analog Power Supply. This pin provides the supply voltage for the analog circuitry in the ADE7755.
The supply should be maintained at 5 V ± 5% for specified operation. Every effort should be made to
minimize power supply ripple and noise at this pin by the use of proper decoupling. This pin should
be decoupled to AGND with a 10 mF capacitor in parallel with a ceramic 100 nF capacitor.
AVDD
4, 19
5, 6
NC
V1P, V1N
No Connect
Analog Inputs for Channel 1 (Current Channel). These inputs are fully differential voltage inputs with
a maximum differential signal level of ±470 mV for specified operation. Channel 1 also has a PGA,
and the gain selections are outlined in Table I. The maximum signal level at these pins is ±1 V with
respect to AGND. Both inputs have internal ESD protection circuitry. An overvoltage of ±6 V can be
sustained on these inputs without risk of permanent damage.
7, 8
V2N, V2P
Negative and Positive Inputs for Channel 2 (Voltage Channel). These inputs provide a fully differential
input pair. The maximum differential input voltage is ±660 mV for specified operation. The maxi-
mum signal level at these pins is ±1 V with respect to AGND. Both inputs have internal ESD
protection circuitry, and an overvoltage of ±6 V can also be sustained on these inputs without risk of
permanent damage.
9
RESET
Reset Pin for the ADE7755. A logic low on this pin will hold the ADCs and digital circuitry in a reset
condition. Bringing this pin logic low will clear the ADE7755 internal registers.
10
REFIN/OUT
This pin provides access to the on-chip voltage reference. The on-chip reference has a nominal value
of 2.5 V ± 8% and a typical temperature coefficient of 30 ppm/∞C. An external reference source may
also be connected at this pin. In either case, this pin should be decoupled to AGND with a 1 mF
ceramic capacitor and 100 nF ceramic capacitor.
11
AGND
This provides the ground reference for the analog circuitry in the ADE7755, i.e., ADCs and reference.
This pin should be tied to the analog ground plane of the PCB. The analog ground plane is the ground
reference for all analog circuitry, e.g., antialiasing filters and current and voltage transducers. For good
noise suppression, the analog ground plane should only connect to the digital ground plane at one
point. A star ground configuration will help to keep noisy digital currents away from the analog circuits.
12
SCF
Select Calibration Frequency. This logic input is used to select the frequency on the calibration output
CF. Table IV shows how the calibration frequencies are selected.
13, 14
S1, S0
These logic inputs are used to select one of four possible frequencies for the digital-to-frequency
conversion. This offers the designer greater flexibility when designing the energy meter. See Selecting
a Frequency for an Energy Meter Application section.
15, 16
17
G1, G0
CLKIN
These logic inputs are used to select one of four possible gains for Channel 1, i.e., V1. The possible
gains are 1, 2, 8, and 16. See Analog Input section.
An external clock can be provided at this logic input. Alternatively, a parallel resonant AT crystal can
be connected across CLKIN and CLKOUT to provide a clock source for the ADE7755. The clock
frequency for specified operation is 3.579545 MHz. Crystal load capacitance of between 22 pF and
33 pF (ceramic) should be used with the gate oscillator circuit.
18
20
CLKOUT
REVP
A crystal can be connected across this pin and CLKIN as described above to provide a clock source
for the ADE7755. The CLKOUT Pin can drive one CMOS load when an external clock is supplied at
CLKIN or by the gate oscillator circuit.
This logic output will go logic high when negative power is detected, i.e., when the phase angle between
the voltage and current signals is greater than 90∞. This output is not latched and will be reset when
positive power is once again detected. The output will go high or low at the same time as a pulse is
issued on CF.
REV. 0
–5–
ADE7755
Pin No.
Mnemonic
Description
21
DGND
This provides the ground reference for the digital circuitry in the ADE7755, i.e., multiplier, filters, and
digital-to-frequency converter. This pin should be tied to the digital ground plane of the PCB. The
digital ground plane is the ground reference for all digital circuitry, e.g., counters (mechanical and
digital), MCUs, and indicator LEDs. For good noise suppression, the analog ground plane should
only be connected to the digital ground plane at one point only, e.g., a star ground.
22
CF
Calibration Frequency Logic Output. The CF logic output gives instantaneous real power informa-
tion. This output is intended to be used for calibration purposes. Also see SCF Pin description.
23, 24
F2, F1
Low Frequency Logic Outputs. F1 and F2 supply average real power information. The logic outputs
can be used to directly drive electromechanical counters and two phase stepper motors. See Transfer
Function section.
ADC OFFSET ERROR
TERMINOLOGY
This refers to the dc offset associated with the analog inputs to
MEASUREMENT ERROR
the ADCs. It means that with the analog inputs connected to
AGND, the ADCs still see a small dc signal (offset). The offset
decreases with increasing gain in Channel V1. This specification
is measured at a gain of 1. At a gain of 16, the dc offset is typi-
cally less than 1 mV. However, when the HPF is switched on,
the offset is removed from the current channel and the power
calculation is not affected by this offset.
The error associated with the energy measurement made by the
ADE7755 is defined by the following formula:
Energy Registered by the ADE7755 – True Energy
Percentage Error =
¥ 100%
True Energy
PHASE ERROR BETWEEN CHANNELS
The HPF (High-Pass Filter) in Channel 1 has a phase lead
response. To offset this phase response and equalize the phase
response between channels, a phase correction network is also
placed in Channel 1. The phase correction network matches the
phase to within ±0.1∞ over a range of 45 Hz to 65 Hz and ±0.2∞
over a range 40 Hz to 1 kHz. See Figures 4 and 5.
GAIN ERROR
The gain error of the ADE7755 is defined as the difference between
the measured output frequency (minus the offset) and the ideal
output frequency. It is measured with a gain of 1 in Channel V1.
The difference is expressed as a percentage of the ideal frequency.
The ideal frequency is obtained from the ADE7755 transfer
function (see Transfer Function section).
POWER SUPPLY REJECTION
This quantifies the ADE7755 measurement error as a percent-
age of the reading when the power supplies are varied.
GAIN ERROR MATCH
For the ac PSR measurement, a reading at nominal supplies
(5 V) is taken. A 200 mV rms/100 Hz signal is then introduced
onto the supplies and a second reading obtained under the same
input signal levels. Any error introduced is expressed as a
percentage of the reading (see Measurement Error definition).
The gain error match is defined as the gain error (minus the off-
set) obtained when switching between a gain of 1 and a gain of 2,
8, or 16. It is expressed as a percentage of the output frequency
obtained under a gain of 1. This gives the gain error observed
when the gain selection is changed from 1 to 2, 8, or 16.
For the dc PSR measurement, a reading at nominal supplies
(5 V) is taken. The supplies are then varied ±5% and a second
reading is obtained with the same input signal levels. Any error
introduced is again expressed as a percentage of the reading.
REV. 0
–6–
Typical Performance Characteristics–ADE7755
0.5
0.4
0.5
–40ꢄC
0.4
–40ꢄC
0.3
0.2
0.3
0.2
0.1
0.0
PF = 1
GAIN = 16
0.1
ON-CHIP REFERENCE
+25ꢄC
+85ꢄC
+25ꢄC
+85ꢄC
0.0
–0.1
–0.2
–0.3
–0.4
–0.5
–0.1
–0.2
–0.3
–0.4
–0.5
PF = 1
GAIN = 1
ON-CHIP REFERENCE
0.1
100
100
100
10
100
1
10
0.01
1
0.01
0.1
Amps
Amps
TPC 1. Error as a % of Reading (Gain = 1)
TPC 4. Error as a % of Reading (Gain = 16)
0.5
0.6
PF = 0.5
–40ꢄC
GAIN = 1
0.4
ON-CHIP REFERENCE
0.4
0.2
0.3
0.2
–40ꢄC PF = 0.5
0.1
+25ꢄC PF = 1
+25ꢄC
0.0
0.0
–0.1
+25ꢄC PF = 0.5
+85ꢄC PF = 0.5
–0.2
–0.4
–0.6
+85ꢄC
–0.2
–0.3
–0.4
–0.5
PF = 1
GAIN = 2
ON-CHIP REFERENCE
0.1
10
1
0.01
100
10
1
0.01
0.1
Amps
Amps
TPC 2. Error as a % of Reading (Gain = 2)
TPC 5. Error as a % of Reading (Gain = 1)
0.6
0.6
PF = 0.5
GAIN = 2
0.5
–40ꢄC
ON-CHIP REFERENCE
0.4
0.2
0.4
0.3
0.2
0.1
–40ꢄC PF = 0.5
PF = 1
GAIN = 8
+25ꢄC PF = 1
ON-CHIP REFERENCE
0.0
+25ꢄC
+85ꢄC
0.0
–0.1
–0.2
–0.3
–0.4
+25ꢄC PF = 0.5
–0.2
–0.4
–0.6
+85ꢄC PF = 0.5
10
1
0.01
0.1
100
10
1
0.01
0.1
Amps
Amps
TPC 3. Error as a % of Reading (Gain = 8)
TPC 6. Error as a % of Reading (Gain = 2)
REV. 0
–7–
ADE7755
0.8
0.6
0.4
0.4
0.3
PF = 0.5
PF = 1
GAIN = 8
GAIN = 16
ON-CHIP REFERENCE
EXTERNAL REFERENCE
–40ꢄC PF = 0.5
–40ꢄC
0.2
0.2
0.0
0.1
+25ꢄC
+25ꢄC PF = 1
0.0
+25ꢄC PF = 0.5
–0.2
–0.4
–0.6
–0.1
–0.2
+85ꢄC
+85ꢄC PF = 0.5
–0.3
–0.4
–0.8
0.01
100
100
10
10
1
1
0.1
0.01
0.1
Amps
Amps
TPC 7. Error as a % of Reading (Gain = 8)
TPC 10. Error as a % of Reading over Temperature
with an External Reference (Gain = 16)
0.4
0.8
0.6
–40ꢄC PF = 0.5
0.2
0.0
PF = 1
0.4
+25ꢄC PF = 1
–0.2
–0.4
–0.6
–0.8
–1.0
0.2
PF = 0.5
+25ꢄC PF = 0.5
0.0
–0.2
–0.4
–0.6
+85ꢄC PF = 0.5
PF = 0.5
GAIN = 16
ON-CHIP REFERENCE
100
10
45
50
55
60
65
70
75
1
0.01
0.1
Amps
FREQUENCY – Hz
TPC 8. Error as a % of Reading (Gain = 16)
TPC 11. Error as a % of Reading over Frequency
V
DD
100nF
AV
100nF
10ꢅF
10ꢅF
40A TO
40mA
0.4
K7
K8
AC/DC DV
U3
DD
DD
PF = 1
F1
F2
CF
NC
GAIN = 2
0.3
1kꢀ
V1P
EXTERNAL REFERENCE
U1
500ꢅꢀ
1.5mꢀ
10mꢀ
33nF
ADE7755
0.2
1kꢀ
–40ꢄC
REVP
NC
CLKOUT
V1N
V2N
V2P
PS2501-1
0.1
33nF
1kꢀ
33pF
+25ꢄC
Y1
0.0
33pF
3.58MHz
33nF
CLKIN
G0
V
DD
1Mꢀ
1kꢀ
–0.1
GAIN
+85ꢄC
SELECT
33nF
10kꢀ
G1
220V
–0.2
S0
S1
SCF
REF
IN/OUT
–0.3
–0.4
100nF
10ꢅF
10nF
10nF
10nF
RESET AGND DGND
100
10
1
0.01
0.1
Amps
NC = NO CONNECT
V
DD
TPC 9. Error as a % of Reading over Temperature
with an External Reference (Gain = 2)
TPC 12. Test Circuit for Performance Curves
REV. 0
–8–
ADE7755
16
14
12
10
8
30
DISTRIBUTION CHARACTERISTICS
NUMBER POINTS: 101
DISTRIBUTION CHARACTERISTICS
NUMBER POINTS: 101
MINIMUM: –2.48959
MINIMUM: –9.78871
GAIN = 1
TEMPERATURE = 25ꢄC
25
20
15
10
MAXIMUM: 7.2939
MEAN: –1.73203
STD. DEV: 3.61157
MAXIMUM: 5.81126
GAIN = 8
TEMPERATURE = 25ꢄC
MEAN: –1.26847
STD. DEV: 1.57404
6
4
5
0
2
0
–15
–9
–3
3
9
15
–15
–9
–3
3
9
15
FREQUENCY – Hz
FREQUENCY – Hz
TPC 13. Channel 1 Offset Distribution (Gain = 1)
TPC 16. Channel 1 Offset Distribution (Gain = 8)
18
35
GAIN = 2
DISTRIBUTION CHARACTERISTICS
NUMBER POINTS: 101
DISTRIBUTION
TEMPERATURE = 25ꢄC
CHARACTERISTICS
NUMBER POINTS: 101
MINIMUM: –5.61779
MAXIMUM: 6.40821
MEAN: –0.01746
16
14
MINIMUM: –1.96823
MAXIMUM: 5.71177
MEAN: –1.48279
30
25
20
15
GAIN = 16
TEMPERATURE = 25ꢄC
STD. DEV: 1.47802
STD. DEV: 2.35129
12
10
8
6
10
5
4
2
0
0
–15
–3
3
9
15
–15
–9
–3
3
9
15
–9
FREQUENCY – Hz
FREQUENCY – Hz
TPC 14. Channel 1 Offset Distribution (Gain = 2)
TPC 17. Channel 1 Offset Distribution (Gain = 16)
0.5
0.5
0.4
0.4
5.25V
5.25V
0.3
0.2
0.3
0.2
0.1
0.1
5V
5V
0
0
–0.1
–0.2
–0.1
–0.2
4.75V
4.75V
–0.3
–0.4
–0.5
–0.6
–0.3
–0.4
–0.5
–0.6
0.01
0.1
1
10
100
0.01
0.1
1
10
100
Amps
Amps
TPC 15. PSR with Internal Reference (Gain = 16)
TPC 18. PSR with External Reference (Gain = 16)
REV. 0
–9–
ADE7755
THEORY OF OPERATION
the voltage by 60∞. If we assume the voltage and current wave-
forms are sinusoidal, the real power component of the instanta-
neous power signal (i.e., the dc term) is given by:
The two ADCs digitize the voltage signals from the current and
voltage transducers. These ADCs are 16-bit second order
sigma-delta with an oversampling rate of 900 kHz. This analog
input structure greatly simplifies transducer interfacing by
providing a wide dynamic range for direct connection to the
transducer and also by simplifying the antialiasing filter design.
A programmable gain stage in the current channel further facili-
tates easy transducer interfacing. A high-pass filter in the current
channel removes any dc component from the current signal.
This eliminates any inaccuracies in the real power calculation
due to offsets in the voltage or current signals (see HPF and
Offset Effects section).
ÊV ¥ I ˆ
¥ cos 60o
(
)
Á
˜
2
Ë
¯
This is the correct real power calculation.
INSTANTANEOUS
POWER SIGNAL
INSTANTANEOUS
REAL POWER SIGNAL
VꢁI
2
The real power calculation is derived from the instantaneous
power signal. The instantaneous power signal is generated by a
direct multiplication of the current and voltage signals. In order
to extract the real power component (i.e., the dc component),
the instantaneous power signal is low-pass filtered. Figure 2
illustrates the instantaneous real power signal and shows how the
real power information can be extracted by low-pass filtering the
instantaneous power signal. This scheme correctly calculates real
power for nonsinusoidal current and voltage waveforms at all
power factors. All signal processing is carried out in the digital
domain for superior stability over temperature and time.
0V
CURRENT
VOLTAGE
INSTANTANEOUS
POWER SIGNAL
INSTANTANEOUS
REAL POWER SIGNAL
VꢁI
2
ꢁcos(60ꢄ)
0V
DIGITAL-TO-
FREQUENCY
VOLTAGE
CURRENT
HPF
60ꢄ
F1
F2
ꢇ
CH1
CH2
PGA
ADC
LPF
Figure 3. DC Component of Instantaneous Power Signal
Conveys Real Power Information PF < 1
MULTIPLIER
DIGITAL-TO-
FREQUENCY
ADC
ꢇ
CF
Nonsinusoidal Voltage and Current
The real power calculation method also holds true for nonsinu-
soidal current and voltage waveforms. All voltage and current
waveforms in practical applications will have some harmonic
content. Using the Fourier Transform, instantaneous voltage
and current waveforms can be expressed in terms of their
harmonic content.
INSTANTANEOUS
INSTANTANEOUS REAL
POWER SIGNAL
POWER SIGNAL – p(t)
VꢁI
p(t) = i(t)ꢁv(t)
WHERE:
VꢁI
2
v(t) = Vꢁcos(ꢆt)
i(t) = Iꢁcos(ꢆt)
VꢁI
{1+cos (2ꢆt)}
VꢁI
2
p(t) =
•
2
v(t) = VO
+
2 ¥ Vh ¥ sin(hwt + ah)
Â
(1)
TIME
hπ0
where:
Figure 2. Signal Processing Block Diagram
v(t) is the instantaneous voltage
VO is the average value
Vh is the rms value of voltage harmonic h
and
The low-frequency output of the ADE7755 is generated by
accumulating this real power information. This low frequency
inherently means a long accumulation time between output
pulses. The output frequency is therefore proportional to the
average real power. This average real power information can, in
turn, be accumulated (e.g., by a counter) to generate real energy
information. Because of its high output frequency and shorter
integration time, the CF output is proportional to the instanta-
neous real power. This is useful for system calibration purposes
that would take place under steady load conditions.
␣h
is the phase angle of the voltage harmonic
•
i(t) = IO
+
2 ¥
Ih ¥ sin(hwt + bh)
Â
(2)
hπ0
where:
i(t) is the instantaneous current
IO
Ih
and
is the dc component
is the rms value of current harmonic h
Power Factor Considerations
The method used to extract the real power information from the
instantaneous power signal (i.e., by low-pass filtering) is still
valid even when the voltage and current signals are not in phase.
Figure 3 displays the unity power factor condition and a DPF
(Displacement Power Factor) = 0.5, i.e., current signal lagging
h is the phase angle of the current harmonic
REV. 0
–10–
ADE7755
Using Equations 1 and 2, the real power P can be expressed in
terms of its fundamental real power (P1) and harmonic real
power (PH).
Table I. Gain Selection for Channel 1
Maximum
Differential Signal
G1
G0
Gain
P = P + PH
1
0
0
1
1
0
1
0
1
1
2
8
16
±470 mV
±235 mV
±60 mV
±30 mV
where:
P = V1 ¥ I1 cos f1
1
(3)
f1 = a1 – b1
Channel V2 (Voltage Channel)
and:
The output of the line voltage transducer is connected to the
ADE7755 at this analog input. Channel V2 is a fully differential
voltage input. The maximum peak differential signal on
Channel 2 is ± 660 mV. Figure 5 illustrates the maximum
signal levels that can be connected to the ADE7755 Channel 2.
PH
=
• Vh ¥ Ihcosfh
Â
hπ1
(4)
fh = ah – bh
As can be seen from Equation 4 above, a harmonic real power
component is generated for every harmonic, provided that har-
monic is present in both the voltage and current waveforms.
The power factor calculation has previously been shown to be
accurate in the case of a pure sinusoid; therefore the harmonic
real power must also correctly account for the power factor
since it is made up of a series of pure sinusoids.
V2
+660mV
V2P
V2N
DIFFERENTIAL INPUT
V2
ꢃ660mV MAX PEAK
V
CM
COMMON-MODE
V
CM
ꢃ100mV MAX
Note that the input bandwidth of the analog inputs is 14 kHz
with a master clock frequency of 3.5795 MHz.
AGND
–660mV
ANALOG INPUTS
Channel V1 (Current Channel)
Figure 5. Maximum Signal Levels, Channel 2
The voltage output from the current transducer is connected to
the ADE7755 here. Channel V1 is a fully differential voltage
input. V1P is the positive input with respect to V1N.
Channel 2 must be driven from a common-mode voltage, i.e.,
the differential voltage signal on the input must be referenced to
a common mode (usually AGND). The analog inputs of the
ADE7755 can be driven with common-mode voltages of up to
100 mV with respect to AGND. However, best results are
achieved using a common mode equal to AGND.
The maximum peak differential signal on Channel 1 should be
less than ±470 mV (330 mV rms for a pure sinusoidal signal) for
specified operation. Note that Channel 1 has a programmable
gain amplifier (PGA) with user selectable gain of 1, 2, 8, or 16
(see Table I). These gains facilitate easy transducer interfacing.
Typical Connection Diagrams
Figure 6 shows a typical connection diagram for Channel V1. A
CT (current transformer) is the current transducer selected for this
example. Notice the common-mode voltage for Channel 1 is
AGND and is derived by center tapping the burden resistor to
AGND. This provides the complementary analog input signals
for V1P and V1N. The CT turns ratio and burden resistor Rb
are selected to give a peak differential voltage of ±470 mV/Gain
at maximum load.
V1
+470mV
V1P
V1N
DIFFERENTIAL INPUT
V1
ꢃ470mV MAX PEAK
V
CM
COMMON-MODE
V
CM
ꢃ100mV MAX
AGND
–470mV
Rf
V1P
V1N
CT
Cf
Cf
ꢃ470mV
GAIN
Rb
Figure 4. Maximum Signal Levels, Channel 1, Gain = 1
AGND
IP
Rf
The diagram in Figure 4 illustrates the maximum signal levels
on V1P and V1N. The maximum differential voltage is ±470 mV
divided by the gain selection. The differential voltage signal on
the inputs must be referenced to a common mode, e.g., AGND.
The maximum common-mode signal is ±100 mV as shown in
Figure 4.
PHASE NEUTRAL
Figure 6. Typical Connection for Channel 1
REV. 0
–11–
ADE7755
Figure 7 shows two typical connections for Channel V2. The first
option uses a PT (potential transformer) to provide complete
isolation from the power line. In the second option, the
ADE7755 is biased around the neutral wire, and a resistor divider
provides a voltage signal that is proportional to the line voltage.
Adjusting the ratio of Ra, Rb, and VR is also a convenient way of
carrying out a gain calibration on the meter.
HPF and Offset Effects
Figure 9 shows the effect of offsets on the real power calculation.
An offset on Channel 1 and Channel 2 will contribute a dc
component after multiplication. Since the dc component is
extracted by the LPF, it will accumulate as real power. If not
properly filtered, dc offsets will introduce error to the energy
accumulation. This problem is easily avoided by enabling the
HPF (i.e., Pin AC/DC is set logic high) in Channel 1. By
removing the offset from at least one channel, no error compo-
nent can be generated at dc by the multiplication. Error terms
at cos(wt) are removed by the LPF and the digital-to-frequency
conversion (see Digital-to-Frequency Conversion section).
V2P
V2N
Rf
CT
Cf
Cf
ꢃ660mV
Rf
AGND
Vcos wt + VOS ¥ Icos wt + IOS
=
PHASE NEUTRAL
(
)
(
)
{
}
{
}
Cf
V ¥ I
Ra
*
+ VOS ¥ IOS + VOS ¥ Icos wt + IOS ¥ Vcos wt
(
)
(
)
2
Rb
*
V2P
V2N
ꢃ660mV
VR
*
V ¥ I
+
¥ cos 2wt
(
)
Rf
2
Cf
*
*
Ra >> Rb + VR
Rb + VR = Rf
PHASE NEUTRAL
Figure 7. Typical Connections for Channel 2
POWER SUPPLY MONITOR
The ADE7755 contains an on-chip power supply monitor. The
Analog Supply (AVDD) is continuously monitored by the ADE7755.
If the supply is less than 4 V ± 5%, the ADE7755 will be reset.
This is useful to ensure correct device startup at power-up and
power-down. The power supply monitor has built in hysteresis
and filtering. This gives a high degree of immunity to false trig-
gering due to noisy supplies.
DC COMPONENT (INCLUDING ERROR TERM)
IS EXTRACTED BY THE LPF FOR REAL
POWER CALCULATION
V
ꢁ I
OS
OS
V ꢁ I
2
I
ꢁ V
OS
V
ꢁ I
OS
2ꢆ
FREQUENCY – RAD/S
0
ꢆ
In Figure 8, the trigger level is nominally set at 4 V. The toler-
ance on this trigger level is about ±5%. The power supply and
decoupling for the part should be such that the ripple at AVDD
does not exceed 5 V ± 5% as specified for normal operation.
Figure 9. Effect of Channel Offset on the Real Power
Calculation
The HPF in Channel 1 has an associated phase response that is
compensated for on-chip. The phase compensation is activated
when the HPF is enabled and is disabled when the HPF is not
activated. Figures 10 and 11 show the phase error between chan-
nels with the compensation network activated. The ADE7755 is
phase compensated up to 1 kHz as shown. This will ensure correct
active harmonic power calculation even at low power factors.
AV
DD
5V
4V
0V
TIME
INTERNAL
RESET
RESET
ACTIVE
RESET
Figure 8. On-Chip Power Supply Monitor
REV. 0
–12–
ADE7755
Figure 12 shows the instantaneous real power signal at the
output of the CPF, which still contains a significant amount of
instantaneous power information, i.e., cos (2 wt). This signal is
then passed to the digital-to-frequency converter where it is
integrated (accumulated) over time to produce an output frequency.
This accumulation of the signal will suppress or average out any
non-dc components in the instantaneous real power signal. The
average value of a sinusoidal signal is zero. Hence, the frequency
generated by the ADE7755 is proportional to the average real
power. Figure 12 shows the digital-to-frequency conversion for
steady load conditions, i.e., constant voltage and current.
0.30
0.25
0.20
0.15
0.10
0.05
0
–0.05
–0.10
F1
DIGITAL-TO-
FREQUENCY
0
100 200 300 400 500 600 700 800 900 1000
FREQUENCY – Hz
F1
F2
ꢇ
V
Figure 10. Phase Error between Channels (0 Hz to 1 kHz)
LPF
TIME
TIME
MULTIPLIER
I
DIGITAL-TO-
FREQUENCY
FOUT
0.30
0.25
0.20
0.15
0.10
0.05
0
ꢇ
CF
LPF TO EXTRACT
REAL POWER
(DC TERM)
V ꢁ I
2
cos(2ꢆt)
ATTENUATED BY LPF
ꢆ
2ꢆ
0
FREQUENCY – RAD/S
INSTANTANEOUS REAL POWER SIGNAL
(FREQUENCY DOMAIN)
–0.05
–0.10
Figure 12. Real Power-to-Frequency Conversion
40
45
50
55
60
65
70
FREQUENCY – Hz
As can be seen in the diagram, the frequency output CF is seen
to vary over time, even under steady load conditions. This
frequency variation is primarily due to the cos (2 wt) component
in the instantaneous real power signal. The output frequency on
CF can be up to 2048 times higher than the frequency on F1
and F2. This higher output frequency is generated by accumu-
lating the instantaneous real power signal over a much shorter
time while converting it to a frequency. This shorter accumula-
tion period means less averaging of the cos (2 wt) component.
As a consequence, some of this instantaneous power signal passes
through the digital-to-frequency conversion. This will not be a
problem in the application. When CF is used for calibration
purposes, the frequency should be averaged by the frequency
counter. This will remove any ripple. If CF is measuring energy,
e.g., in a microprocessor-based application, the CF output
should also be averaged to calculate power. Because the outputs
F1 and F2 operate at a much lower frequency, more averaging
of the instantaneous real power signal is carried out. The result
is a greatly attenuated sinusoidal content and a virtually ripple-
free frequency output.
Figure 11. Phase Error between Channels (40 Hz to 70 Hz)
DIGITAL-TO-FREQUENCY CONVERSION
As previously described, the digital output of the low-pass filter
after multiplication contains the real power information. How-
ever, since this LPF is not an ideal “brick wall” filter implemen-
tation, the output signal also contains attenuated components
at the line frequency and its harmonics, i.e., cos(hwt) where
h = 1, 2, 3, and so on.
The magnitude response of the filter is given by:
1
|H( f )|=
(5)
1+( f /8.9 Hz)
For a line frequency of 50 Hz this would give an attenuation of
the 2w (100 Hz) component of approximately –22 dBs. The
dominating harmonic will be at twice the line frequency, i.e.,
cos (2 wt), and this is due to the instantaneous power signal.
REV. 0
–13–
ADE7755
Interfacing the ADE7755 to a Microcontroller for Energy
Measurement
Power Measurement Considerations
Calculating and displaying power information will always have
some associated ripple that will depend on the integration period
used in the MCU to determine average power and also the load.
For example, at light loads, the output frequency may be 10 Hz.
With an integration period of two seconds, only about 20 pulses
will be counted. The possibility of missing one pulse always exists,
since the ADE7755 output frequency is running asynchronously
to the MCU timer. This would result in a one-in-twenty (or
5%) error in the power measurement.
The easiest way to interface the ADE7755 to a microcontroller
is to use the CF high-frequency output with the output frequency
scaling set to 2048 ¥ F1, F2. This is done by setting SCF = 0
and S0 = S1 = 1 (see Table IV). With full-scale ac signals on the
analog inputs, the output frequency on CF will be approximately
5.5 kHz. Figure 13 illustrates one scheme that could be used to
digitize the output frequency and carry out the necessary
averaging mentioned in the previous section.
CF
TRANSFER FUNCTION
Frequency Outputs F1 and F2
FREQUENCY
RIPPLE
The ADE7755 calculates the product of two voltage signals (on
Channel 1 and Channel 2) and then low-pass filters this product
to extract real power information. This real power information
is then converted to a frequency. The frequency information is
output on F1 and F2 in the form of active low pulses. The pulse
rate at these outputs is relatively low, e.g., 0.34 Hz maximum
for ac signals with S0 = S1 = 0 (see Table III). This means that
the frequency at these outputs is generated from real power
information accumulated over a relatively long period of time.
The result is an output frequency that is proportional to the
average real power. The averaging of the real power signal is
implicit to the digital-to-frequency conversion. The output
frequency or pulse rate is related to the input voltage signals by
the following equation.
AVERAGE
ꢃ10%
FREQUENCY
TIME
MCU
ADE7755
COUNTER
CF
UP/DOWN
REVP
*
TIMER
8.06 ¥ V1 ¥ V2 ¥ Gain ¥ F1-4
Freq =
2
VREF
*
REVP MUST BE USED IF THE METER IS BIDIRECTIONAL OR
DIRECTION OF ENERGY FLOW IS NEEDED
where:
Figure 13. Interfacing the ADE7755 to an MCU
Freq = Output frequency on F1 and F2 (Hz)
V1 = Differential rms voltage signal on Channel 1 (Volts)
V2 = Differential rms voltage signal on Channel 2 (Volts)
As shown, the frequency output CF is connected to an MCU
counter or port. This will count the number of pulses in a given
integration time that is determined by an MCU internal timer.
The average power proportional to the average frequency is
given by:
Gain = 1, 2, 8, or 16, depending on the PGA gain selection
made using logic inputs G0 and G1
VREF = The reference voltage (2.5 V ± 8%) (Volts)
Counter
F
1–4 = One of four possible frequencies selected by using the
logic inputs S0 and S1—see Table II
Average Frequency = Average Real Power =
Timer
The energy consumed during an integration period is given by:
Table II. F1–4 Frequency Selection
S1
S0
F1–4 (Hz)
XTAL/CLKIN*
Counter
Energy = Average Power ¥ Time =
¥ Time = Counter
0
0
1
1
0
1
0
1
1.7
3.4
6.8
13.6
3.579 MHz/221
3.579 MHz/220
3.579 MHz/219
3.579 MHz/218
Time
For the purpose of calibration, this integration time can be 10 to
20 seconds to accumulate enough pulses to ensure correct aver-
aging of the frequency. In normal operation, the integration time
can be reduced to one or two seconds depending, for example,
on the required undate rate of a display. With shorter integra-
tion times on the MCU, the amount of energy in each update
may still have some small amount of ripple, even under steady
load conditions. However, over a minute or more, the measured
energy will have no ripple.
NOTE
*F1–4 is a binary fraction of the master clock and therefore will vary if the speci-
fied CLKIN frequency is altered.
REV. 0
–14–
ADE7755
Example 1
pulse rate, the frequency at this logic output is proportional to
the instantaneous real power. As is the case with F1 and F2, the
frequency is derived from the output of the low-pass filter after
multiplication. However, because the output frequency is high,
this real power information is accumulated over a much shorter
time. Hence, less averaging is carried out in the digital-to-
frequency conversion. With much less averaging of the real
power signal, the CF output is much more responsive to power
fluctuations (see Figure 2, signal processing block diagram).
Thus if full-scale differential dc voltages of +470 mV and –660 mV
are applied to V1 and V2 respectively (470 mV is the maximum
differential voltage that can be connected to Channel 1, and
660 mV is the maximum differential voltage that can be connected
to Channel 2), the expected output frequency is calculated as
follows:
Gain = 1, G0 = G1 = 0
F1–4 = 1.7 Hz, S0 = S1 = 0
Table IV. Maximum Output Frequency on CF
V1 = +470 mV dc = 0.47 V (rms of dc = dc)
V2 = –660 mV dc = 0.66 V (rms of dc = |dc|)
SCF S1
S0 F1–4 (Hz)
CF Max for AC Signals (Hz)
V
REF = 2.5 V (nominal reference value)
1
0
1
0
1
0
1
0
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
1.7
1.7
3.4
3.4
6.8
6.8
13.6
13.6
128 ¥ F1, F2 = 43.52
64 ¥ F1, F2 = 21.76
64 ¥ F1, F2 = 43.52
32 ¥ F1, F2 = 21.76
32 ¥ F1, F2 = 43.52
16 ¥ F1, F2 = 21.76
16 ¥ F1, F2 = 43.52
2048 ¥ F1, F2 = 5.57 kHz
NOTE: If the on-chip reference is used, actual output frequencies
may vary from device to device due to reference tolerance of ±8%.
8.06 ¥ 0.47 ¥ 0.66 ¥ 1 ¥ 1.7
Freq =
= 0.68
2.52
Example 2
In this example, with ac voltages of ±470 mV peak applied to
V1 and ±660 mV peak applied to V2, the expected output
frequency is calculated as follows:
SELECTING A FREQUENCY FOR AN ENERGY METER
APPLICATION
Gain = 1, G0 = G1 = 0
As shown in Table II, the user can select one of four frequencies.
This frequency selection determines the maximum frequency on
F1 and F2. These outputs are intended to be used to drive the
energy register (electromechanical or other). Since only four
different output frequencies can be selected, the available fre-
quency selection has been optimized for a meter constant of
100 imp/kWhr with a maximum current of between 10 A and
120 A. Table V shows the output frequency for several maxi-
mum currents (IMAX) with a line voltage of 220 V. In all cases
the meter constant is 100 imp/kWhr.
F
1–4 = 1.7 Hz, S0 = S1 = 0
V1 = rms of 470 mV peak ac = 0.47/÷2 volts
V2 = rms of 660 mV peak ac = 0.66/÷2 volts
V
REF = 2.5 V (nominal reference value)
NOTE: If the on-chip reference is used, actual output frequencies
may vary from device to device due to reference tolerance of ±8%.
8.06 ¥ 0.47 ¥ 0.66 ¥ 1 ¥ 1.7
Freq =
= 0.34
2 ¥ 2 ¥ 2.52
Table V. F1 and F2 Frequency at 100 imp/kWhr
As can be seen from these two example calculations, the maxi-
mum output frequency for ac inputs is always half of that for dc
input signals. Table III shows a complete listing of all maximum
output frequencies.
IMAX
F1 and F2 (Hz)
12.5 A
25 A
40 A
60 A
80 A
0.076
0.153
0.244
0.367
0.489
0.733
Table III. Maximum Output Frequency on F1 and F2
Max Frequency
for DC Inputs (Hz)
Max Frequency
for AC Inputs (Hz)
S1
S0
120 A
0
0
1
1
0
1
0
1
0.68
1.36
2.72
5.44
0.34
0.68
1.36
2.72
The F1–4 frequencies allow complete coverage of this range of
output frequencies on F1 and F2. When designing an energy
meter, the nominal design voltage on Channel 2 (voltage) should
be set to half scale to allow for calibration of the meter constant.
The current channel should also be no more than half scale
when the meter sees maximum load. This will allow over current
signals and signals with high crest factors to be accommodated.
Table VI shows the output frequency on F1 and F2 when both
analog inputs are half scale. The frequencies listed in Table
VI align very well with those listed in Table V for maximum load.
Frequency Output CF
The pulse output CF (Calibration Frequency) is intended for
use during calibration. The output pulse rate on CF can be up
to 2048 times the pulse rate on F1 and F2. The lower the F1–4
frequency selected, the higher the CF scaling (except for the
high-frequency mode SCF = 0, S1 = S0 = 1). Table IV shows
how the two frequencies are related, depending on the states of
the logic inputs S0, S1, and SCF. Because of its relatively high
REV. 0
–15–
ADE7755
Table VI. F1 and F2 Frequency with Half-Scale AC Inputs
The high-frequency CF output is intended to be used for com-
munications and calibration purposes. CF produces a 90 ms-wide
active high pulse (t4) at a frequency proportional to active
power. The CF output frequencies are given in Table IV. As in
the case of F1 and F2, if the period of CF (t5) falls below 180 ms,
the CF pulsewidth is set to half the period. For example, if the CF
frequency is 20 Hz, the CF pulsewidth is 25 ms.
Frequency on F1 and F2
CH1 and CH2 Half-Scale AC Inputs
S1
S0
F1–4
0
0
1
1
0
1
0
1
1.7
3.4
6.8
13.6
0.085 Hz
0.17 Hz
0.34 Hz
0.68 Hz
NOTE: When the high-frequency mode is selected, (i.e., SCF = 0,
S1 = S0 = 1), the CF pulsewidth is fixed at 18 ms. Therefore, t4 will
always be 18 ms, regardless of the output frequency on CF.
When selecting a suitable F1–4 frequency for a meter design, the
frequency output at IMAX (maximum load) with a meter constant
of 100 imp/kWhr should be compared with Column 4 of Table
VI. The frequency that is closest in Table VI will determine the
best choice of frequency (F1–4). For example, if a meter with a
maximum current of 25 A is being designed, the output frequency
on F1 and F2 with a meter constant of 100 imp/kWhr is 0.153 Hz
at 25 A and 220 V (from Table V). Looking at Table VI, the
closest frequency to 0.153 Hz in column four is 0.17 Hz.
Therefore, F2 (3.4 Hz—see Table II) is selected for this design.
NO LOAD THRESHOLD
The ADE7755 also includes a “no load threshold” and “start-
up current” feature that will eliminate any creep effects in the
meter. The ADE7755 is designed to issue a minimum output
frequency on all modes except when SCF = 0 and S1 = S0 = 1.
The no-load detection threshold is disabled on this output mode
to accommodate specialized application of the ADE7755. Any
load generating a frequency lower than this minimum frequency
will not cause a pulse to be issued on F1, F2, or CF. The mini-
mum output frequency is given as 0.0014% of the full-scale
output frequency for each of the F1–4 frequency selections (see
Table II). For example, an energy meter with a meter constant
of 100 imp/kWhr on F1 and F2 using F2 (3.4 Hz), the maximum
output frequency at F1 or F2 would be 0.0014% of 3.4 Hz or
4.76 ¥ 10–5 Hz. This would be 3.05 ¥ 10–3 Hz at CF (64 ¥ F1 Hz).
In this example, the no-load threshold is equivalent to 1.7 W of
load or a start-up current of 8 mA at 220 V. IEC1036 states that
the meter must start up with a load current equal to or less than
0.4% Ib. For a 5A (Ib) meter, 0.4% Ib is equivalent to 20mA.
The start-up current of this design therefore satisfies the IEC
requirement. As illustrated from this example, the choice of F1–
F4 and the ratio of the stepper motor display will determine the
start-up current.
Frequency Outputs
Figure 1 shows a timing diagram for the various frequency outputs.
The outputs F1 and F2 are the low-frequency outputs that can
be used to directly drive a stepper motor or electromechanical
impulse counter. The F1 and F2 outputs provide two alternat-
ing low going pulses. The pulsewidth (t1) is set at 275 ms and the
time between the falling edges of F1 and F2 (t3) is approxi-
mately half the period of F1 (t2). If, however, the period of
F1 and F2 falls below 550 ms (1.81 Hz), the pulsewidth of F1
and F2 is set to half of their period. The maximum output fre-
quencies for F1 and F2 are shown in Table III.
OUTLINE DIMENSIONS
Dimensions shown in inches and (mm)
24-Lead Shrink Small Outline Package
(RS-24)
0.328 (8.33)
0.318 (8.08)
24
1
13
12
0.311 (7.9)
0.301 (7.64)
0.212 (5.38)
0.205 (5.207)
PIN 1
0.07 (1.78)
0.066 (1.67)
0.078 (1.98)
0.068 (1.73)
8°
0°
0.0256
(0.65)
BSC
0.015 (0.38)
0.010 (0.25)
0.008 (0.203)
0.002 (0.050)
SEATING 0.009 (0.229)
0.037 (0.94)
0.022 (0.559)
PLANE
0.005 (0.127)
REV. 0
–16–
相关型号: