Polyphase Energy Metering IC with Pulsed  
Output  
Preliminary Technical Data  
ADE7752B  
FEATURES  
High accuracy supports 50 Hz/60 Hz IEC62053-21  
The no-load threshold and reverse polarity indication are based  
on the sum of the three phase energies in the ADE7752B. The  
Less than 0.1% error over a dynamic range of 500 to 1  
Compatible with 3-phase 3-wire delta and 3-phase 4-wire Wye  
configurations  
Supplies average active power on the frequency outputs F1 and F2  
High frequency output (CF) is intended for calibration and  
supplies instantaneous active power  
Logic output REVP indicates a potential miswiring or negative  
power on the sum of all phases  
Direct drive for electromechanical counters and 2-phase stepper  
motors (F1 and F2)  
Proprietary ADCs and DSP provide high accuracy over large  
variations in environmental conditions and time  
On-chip power supply monitoring  
ADE7752B specifications surpass the accuracy requirements as  
quoted in the IEC62053-21 standard.  
The only analog circuitry used in the ADE7752B is in the  
analog-to-digital converters (ADCs) and reference circuit. All  
other signal processing (for example, multiplication, filtering,  
and summation) is carried out in the digital domain. This  
approach provides superior stability and accuracy over  
extremes in environmental conditions and over time.  
The ADE7752B supplies average active power information on  
the low frequency outputs, F1 and F2. These logic outputs can  
be used to directly drive an electromechanical counter or to  
interface with an MCU. The CF logic output gives  
On-chip creep protection (no load threshold) based on the sum  
of the three phases  
instantaneous active power information. This output is  
intended to be used for calibration purposes.  
On-chip reference 2.4 V 8% (25 ppm/°C typical) with external  
overdrive capability  
Single 5 V supply, low power (TBD mW typical)  
Low cost CMOS process  
The ADE7752B includes a power supply monitoring circuit on  
the VDD pin. The ADE7752B remains inactive until the supply  
voltage on VDD reaches 4 V. If the supply falls below 4 V, the  
ADE7752B also resets and no pulses are issued on F1, F2, and CF.  
GENERAL DESCRIPTION  
The ADE7752B1 is an accurate active energy measurement IC  
intended for use in any 3-phase distribution system and has  
enhanced features that make it better suited for 3-phase 3-wire  
applications compared to the ADE7752/52A.  
Internal phase matching circuitry ensures that the voltage and  
current channels are phase matched. An internal no load  
threshold ensures the ADE7752B does not exhibit any creep  
when there is no load.  
The ADE7752B is available in a 24-lead SOIC package.  
1 Patent pending.  
FUNCTIONAL BLOCK DIAGRAM  
V
ABS  
17  
DD  
3
5
6
IAP  
IAN  
VA P  
ADC  
ADC  
X
X
POWER  
SUPPLY  
MONITOR  
HPF  
LPF  
LPF  
LPF  
16  
Φ
PHASE  
CORRECTION  
ADE7752B  
IBP  
IBN  
7
8
ADC  
ADC  
Σ
2
HPF  
DGND  
15  
VBP  
Φ
19  
20  
CLKIN  
PHASE  
CORRECTION  
CLKOUT  
9
ICP  
ADC  
ADC  
X
ICN 10  
HPF  
VCP  
VN  
14  
13  
Φ
DIGITAL-TO-FREQUENCY CONVERTER  
PHASE  
CORRECTION  
4kΩ  
2.4V REF  
11  
12  
4
18  
21  
22  
23  
24  
1
AGND  
REF  
IN/OUT  
REVP  
SCF  
S0  
S1  
F2  
F1  
CF  
Figure 1.  
Rev. PrA  
Information furnished by Analog Devices is believed to be accurate and reliable. However, no  
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other  
rights of third parties that may result from its use. Specifications subject to change without notice. No  
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.  
Trademarks and registeredtrademarks arethe property of their respective owners.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700  
Fax: 781.461.3113  
www.analog.com  
© 2006 Analog Devices, Inc. All rights reserved.  
ADE7752B  
Preliminary Technical Data  
TABLE OF CONTENTS  
Features .............................................................................................. 1  
Current Channel Connection................................................... 16  
Voltage Channels Connection.................................................. 16  
Meter Connections..................................................................... 16  
Power Supply Monitor ................................................................... 18  
HPF and Offset Effects .................................................................. 19  
Digital-to-Frequency Conversion ................................................ 20  
Power Measurement Considerations....................................... 21  
Mode Selection of the Sum of the Three Active Energies..... 21  
Transfer Function........................................................................... 22  
Frequency Outputs F1 and F2 .................................................. 22  
Frequency Output CF................................................................ 23  
Selecting a Frequency for an Energy Meter Application........... 24  
Frequency Outputs..................................................................... 24  
No Load Threshold .................................................................... 24  
Negative Power Information..................................................... 25  
Outline Dimensions....................................................................... 26  
Ordering Guide .......................................................................... 26  
General Description......................................................................... 1  
Table of Contents.............................................................................. 2  
Specifications..................................................................................... 3  
Timing Characteristics ................................................................ 5  
Absolute Maximum Ratings............................................................ 6  
ESD Caution.................................................................................. 6  
Pin Configuration and Function Descriptions............................. 7  
Typical Performance Characteristics ............................................. 9  
Terminology .................................................................................... 11  
Test Circuit ...................................................................................... 12  
Theory of Operation ...................................................................... 13  
Power Factor Considerations.................................................... 13  
Nonsinusoidal Voltage and Current ........................................ 14  
Analog Inputs.................................................................................. 15  
Current Channels ....................................................................... 15  
Voltage Channels........................................................................ 15  
Typical Connection Diagrams...................................................... 16  
Rev. PrA | Page 2 of 27  
Preliminary Technical Data  
SPECIFICATIONS  
ADE7752B  
VDD = 5 V ± 5ꢀ, AGND = DGND = 0 V, on-chip reference, CLKIN = 10 MHz, TMIN to TMAX = −40°C to +85°C, unless otherwise noted.  
Table 1.  
Parameter  
ACCURACY1, 2  
Conditions  
Min  
Typ  
Max  
Unit  
Measurement Error on  
Current Channel  
Voltage channel with full-scale signal (±±55 mV),  
2±°C, over a dynamic range of ±55 to 1  
5.1  
% Reading  
Phase Error Between  
Channels  
PF = 5.8 Capacitive  
PF = 5.± Capacitive  
±5.1  
±5.1  
Degrees  
Degrees  
AC Power Supply Rejection  
SCF = 5, S5 = S1 = 1  
Output Frequency  
Variation (CF)  
IA = IB = IC = 155 mV rms,  
VA = VB = VC = 155 mV rms @ ±5 Hz,  
Ripple on VDD of 255 mV rms @ 155 Hz  
5.51  
5.1  
% Reading  
DC Power Supply Rejection S1 = 1; S5 = SCF = 5  
Output Frequency  
Variation (CF)  
V1 = 155 mV rms, V2 = 155 mV rms,  
VDD = ± V ± 2±5 mV  
% Reading  
ANALOG INPUTS  
See Analog Inputs section  
Maximum Signal Levels  
VAP – VN, VBP – VN, VCP – VN, IAP – IAN, IBP – IBN, ICP – ICN  
±5.±  
V peak  
difference  
Input Impedance (DC)  
Bandwidth (−3 dB)  
ADC Offset Error1, 2  
Gain Error  
CLKIN = 15 MHz  
CLKIN/2±6, CLKIN = 15 MHz  
375  
415  
14  
kΩ  
kHz  
mV  
% Ideal  
±2±  
2.6  
External 2.± V reference, IA = IB = IC = ±55 mV dc  
±ꢀ  
REFERENCE INPUT  
REFIN/OUT Input Voltage  
Range  
2.4 V + 8%  
2.4 V − 8%  
V
2.2  
3.3  
V
kΩ  
pF  
Input Impedance  
Input Capacitance  
ON-CHIP REFERENCE  
Reference Error  
15  
Nominal 2.4 V  
±255  
mV  
Temperature Coefficient  
CLKIN  
Input Clock Frequency  
LOGIC INPUTS3  
2±  
15  
ppm/°C  
All specifications for CLKIN of 15 MHz  
MHz  
ACF, S5, S1, and ABS  
Input High Voltage, VINH  
Input Low Voltage, VINL  
Input Current, IIN  
Input Capacitance, CIN  
LOGIC OUTPUTS3  
F1 and F2  
VDD = ± V ± ±%  
VDD = ± V ± ±%  
Typically 15 nA, VIN = 5 V to VDD  
2.4  
V
V
μA  
pF  
5.8  
±3  
15  
Output High Voltage, VOH ISOURCE = 15 mA, VDD = ± V  
4.±  
4.±  
V
V
Output Low Voltage, VOL  
CF and NEGP  
ISINK = 15 mA, VDD = ± V  
5.±  
5.±  
Output High Voltage, VOH VDD = ± V, ISOURCE = ± mA  
V
V
Output Low Voltage, VOL  
LED_CTRL  
VDD = ± V, ISINK = ± mA  
VDD = ± V, CLKIN = 15 MHz  
Output Frequency  
Output High Voltage  
Output Low Voltage  
17.3ꢀ  
kHz  
V
V
VDD = ± V, ISOURCE = 15 mA  
VDD = ± V, ISINK = 15 mA  
4.±  
TBD  
Rev. PrA | Page 3 of 27  
ADE7752B  
Preliminary Technical Data  
Parameter  
Conditions  
Min  
Typ  
Max  
Unit  
LED_A, LED_B, LED_C  
Output Low ISINK  
Output High Source  
POWER SUPPLY  
VDD  
VDD = 4.7± V  
VDD = 4.7± V  
TBD  
TBD  
mA  
mA  
For specified performance  
± V ± ±%  
4.7±  
±.2±  
TBD  
V
mA  
IDD  
TBD  
1 See the Terminology section for explanation of specifications.  
2 See the plots in the Typical Performance Characteristics section.  
3 Sample tested during initial release and after any redesign or process changes that might affect this parameter.  
Rev. PrA | Page 4 of 27  
Preliminary Technical Data  
ADE7752B  
TIMING CHARACTERISTICS  
VDD = 5 V ± 5ꢀ, AGND = DGND = 0 V, on-chip reference, CLKIN = 10 MHz, TMIN to TMAX = −40°C to +85°C, unless otherwise noted.  
Table 2.  
Parameter1,2  
Conditions  
Specification  
Unit  
ms  
sec  
3
t1  
t2  
F1 and F2 pulse width (logic high)  
Output pulse period (see the Transfer Function section)  
125  
See Figure 2  
1/2 t2  
t3  
Time between F1 falling edge and F2 falling edge  
CF pulse width (logic high)  
sec  
ms  
sec  
sec  
3, 4  
t4  
90  
±
t±  
CF pulse period (see the Transfer Function section)  
Minimum time between F1 and F2 pulse  
See Table 7  
4/CLKIN  
t6  
1 Sample tested during initial release and after any redesign or process changes that might affect this parameter.  
2 See Figure 2.  
3 The pulse widths of F1, F2, and CF are not fixed for higher output frequencies (see the Frequency Outputs section).  
4 CF is not synchronous to F1 or F2 frequency outputs.  
± The CF pulse is always 1 μs in the high frequency mode (see the Frequency Outputs section).  
t1  
F1  
t6  
t2  
t3  
F2  
t5  
t4  
CF  
Figure 2. Timing Diagram for Frequency Outputs  
Rev. PrA | Page ± of 27  
ADE7752B  
Preliminary Technical Data  
ABSOLUTE MAXIMUM RATINGS  
TA = 25°C, unless otherwise noted.  
Table 3.  
Stresses above those listed under Absolute Maximum Ratings  
may cause permanent damage to the device. This is a stress  
rating only; functional operation of the device at these or any  
other conditions above those indicated in the operational  
section of this specification is not implied. Exposure to absolute  
maximum rating conditions for extended periods may affect  
device reliability.  
Parameter  
Rating  
VDD to AGND  
VDD to DGND  
−5.3 V to +7 V  
−5.3 V to +7 V  
Analog Input Voltage to AGND  
VA P, V B P, V C P, V N , I A P, I A N , I B P, I B N , I C P,  
and ICN  
−6 V to +6 V  
Reference Input Voltage to AGND  
Digital Input Voltage to DGND  
Digital Output Voltage to DGND  
Operating Temperature Range  
Industrial  
−5.3 V to VDD + 5.3 V  
−5.3 V to VDD + 5.3 V  
−5.3 V to VDD + 5.3 V  
−45°C to +8±°C  
−6±°C to +1±5°C  
1±5°C  
Storage Temperature Range  
Junction Temperature  
28-Lead SOIC, Power Dissipation  
θJA Thermal Impedance  
Lead Temperature, Soldering  
Vapor Phase (65 sec)  
63 mW  
±±°C/W  
21±°C  
225°C  
Infrared (1± sec)  
ESD CAUTION  
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4555 V readily accumulate on  
the human body and test equipment and can discharge without detection. Although this product features  
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy  
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance  
degradation or loss of functionality.  
Rev. PrA | Page 6 of 27  
Preliminary Technical Data  
ADE7752B  
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS  
F1  
CF  
1
24  
23  
22  
21  
20  
19  
18  
17  
16  
F2  
DGND  
2
V
S1  
3
DD  
S0  
4
REVP  
IAP  
CLKOUT  
CLKIN  
SCF  
ABS  
VAP  
5
ADE7752B  
6
IAN  
TOP VIEW  
(Not to Scale)  
7
IBP  
8
IBN  
9
ICP  
10  
11  
12  
15 VBP  
14 VCP  
13 VN  
ICN  
AGND  
REF  
IN/OUT  
Figure 3. Pin Configuration  
Table 4. Pin Function Descriptions  
Pin No.  
Mnemonic  
Description  
1
CF  
Calibration Frequency Logic Output. The CF logic output gives instantaneous active power information.  
This output is intended to be used for calibration purposes.  
2
3
4
DGND  
VDD  
This provides the ground reference for the digital circuitry in the ADE77±2B, that is, multiplier, filters,  
and digital-to-frequency converter. Because the digital return currents in the ADE77±2B are small, it is  
acceptable to connect this pin to the analog ground plane of the whole system.  
Power Supply. This pin provides the supply voltage for the digital circuitry in the ADE77±2B. The supply  
voltage should be maintained at ± V ± ±% for specified operation. This pin should be decoupled to  
DGND with a 15 μF capacitor in parallel with a 155 nF ceramic capacitor.  
This logic output goes logic high when negative power is detected on the sum of the three phase  
powers. This output is not latched and resets when positive power is once again detected (see the  
Negative Power Information section).  
REVP  
±, 6;  
7, 8;  
ꢀ, 15  
IAP, IAN;  
IBP, IBN;  
ICP, ICN  
Analog Inputs for Current Channels. These channels are intended for use with current transducers and  
are referenced in this document as current channels. These inputs are fully differential voltage inputs  
with maximum differential input signal levels of ±5.± V (see the Analog Inputs section). Both inputs  
have internal ESD protection circuitry; in addition, an overvoltage of ±6 V can be sustained on these  
inputs without risk of permanent damage.  
11  
AGND  
This pin provides the ground reference for the analog circuitry in the ADE77±2B (ADCs and reference).  
This pin should be tied to the analog ground plane or the quietest ground reference in the system. This  
quiet ground reference should be used for all analog circuitry, such as, anti-aliasing filters and current  
and voltage transducers. To keep ground noise around the ADE77±2B to a minimum, the quiet ground  
plane should only connect to the digital ground plane at one point. It is acceptable to place the entire  
device on the analog ground plane.  
12  
REFIN/OUT  
This pin provides access to the on-chip voltage reference. The on-chip reference has a nominal value of  
2.4 V ±8% and a typical temperature coefficient of 2± ppm/°C. An external reference source can also be  
connected at this pin. In either case, this pin should be decoupled to AGND with a 1 μF ceramic  
capacitor.  
13, 14, 1±, VN, VCP, VBP, VAP  
16  
Analog Inputs for the Voltage Channels. These channels are intended for use with voltage transducers  
and are referenced in this document as voltage channels. These inputs are single-ended voltage inputs  
with a maximum signal level of ±5.± V with respect to VN for specified operation. All inputs have  
internal ESD protection circuitry; in addition, an overvoltage of ±6 V can be sustained on these inputs  
without risk of permanent damage.  
17  
ABS  
This logic input is used to select the method by which the three active energies from each phase are  
summed. It selects between the arithmetical sum of the three energies (ABS logic high) or the sum of  
the absolute values (ABS logic low). See the Mode Selection of the Sum of the Three Active Energies  
section.  
18  
1ꢀ  
SCF  
Select Calibration Frequency. This logic input is used to select the frequency on the calibration output  
CF. Table 7 shows how the calibration frequencies are selected.  
CLKIN  
Master Clock for the ADCs and Digital Signal Processing. An external clock can be provided at this logic  
input. Alternatively, a parallel resonant AT crystal can be connected across CLKIN and CLKOUT to  
provide a clock source for the ADE77±2B. The clock frequency for the specified operation is 15 MHz.  
Ceramic load capacitors between 22 pF and 33 pF should be used with the gate oscillator circuit. Refer  
to the crystal manufacturer’s data sheet for the load capacitance requirements.  
Rev. PrA | Page 7 of 27  
ADE7752B  
Preliminary Technical Data  
Pin No.  
Mnemonic  
Description  
25  
CLKOUT  
A crystal can be connected across this pin and CLKIN as described previously to provide a clock source  
for the ADE77±2B. The CLKOUT pin can drive one CMOS load when an external clock is supplied at  
CLKIN or when a crystal is being used.  
21, 22  
23, 24  
S5, S1  
F2, F1  
These logic inputs are used to select one of four possible frequencies for the digital-to-frequency  
conversion for design flexibility.  
Low Frequency Logic Outputs. F1 and F2 supply average active power information. The logic outputs  
can be used to drive electromechanical counters and 2-phase stepper motors directly (see the Transfer  
Function section).  
Rev. PrA | Page 8 of 27  
Preliminary Technical Data  
ADE7752B  
TYPICAL PERFORMANCE CHARACTERISTICS  
Figure 4. Error as a Percent of Reading  
with Internal Reference (Wye Connection)  
Figure 7. Error as a Percent of Reading over Temperature  
with Internal Reference (Wye Connection)  
Figure 5. Error as a Percent of Reading over Power Factor  
with Internal Reference (Wye Connection)  
Figure 8. Error as a Percent of Reading over Power Factor  
with Internal Reference (Delta Connection)  
Figure 6. Error as a Percent of Reading over Power Factor  
with External Reference (Wye Connection)  
Figure 9. Error as a Percent of Reading over Temperature  
with External Reference (Wye Connection)  
Rev. PrA | Page ꢀ of 27  
ADE7752B  
Preliminary Technical Data  
Figure 10. Error as a Percent of Reading over Frequency  
Figure 12. Channel 1 Offset Distribution  
with an Internal Reference (Wye Connection)  
Figure 13. Error as a Percent of Reading over Power Supply  
with Internal Reference (Wye Connection)  
Figure 11. Error as a Percent of Reading over Power Supply  
with External Reference (Wye Connection)  
Rev. PrA | Page 15 of 27  
Preliminary Technical Data  
TERMINOLOGY  
ADE7752B  
ADC Offset Error  
Measurement Error  
This refers to the dc offset associated with the analog inputs to  
the ADCs. It means that with the analog inputs connected to  
AGND, the ADCs still see an analog input signal offset.  
However, because the HPF is always present, the offset is  
removed from the current channel and the power calculation is  
not affected by this offset.  
The error associated with the energy measurement made by the  
ADE7752B is defined by the following formula:  
Energy Registered by ADE7762 True Energy  
Percentage Error =  
×100%  
True Energy  
Error between Channels  
The high-pass filter (HPF) in the current channel has a phase  
lead response. To offset this phase response and equalize the  
phase response between channels, a phase correction network is  
placed in the current channel. The phase correction network  
ensures a phase match between the current channels and  
voltage channels to within ±0.1° over a range of 45 Hz to 65 Hz  
and ±0.2° over a range of 40 Hz to 1 kHz (see Figure 25 and  
Figure 26).  
Gain Error  
The gain error of the ADE7752B is defined as the difference  
between the measured output frequency (minus the offset) and  
the ideal output frequency. The difference is expressed as a  
percentage of the ideal frequency. The ideal frequency is  
obtained from the ADE7752B transfer function (see the  
Transfer Function section).  
Power Supply Rejection (PSR)  
This quantifies the ADE7752B measurement error as a  
percentage of reading when the power supplies are varied.  
For the ac PSR measurement, a reading at a nominal supply  
(5 V) is taken. A 200 mV rms/100 Hz signal is then introduced  
onto the supply and a second reading is obtained under the  
same input signal levels. Any error introduced is expressed as a  
percentage of reading. See definition for Measurement Error.  
For the dc PSR measurement, a reading at nominal supplies  
(5 V) is taken. The supply is then varied ±5ꢀ and a second  
reading is obtained with the same input signal levels. Any error  
introduced is again expressed as a percentage of reading.  
Rev. PrA | Page 11 of 27  
ADE7752B  
Preliminary Technical Data  
TEST CIRCUIT  
V
DD  
100nF  
10μF  
3
17  
I
LOAD  
K7  
24  
23  
V
IAP  
F1  
F2  
ABS  
DD  
1kΩ  
33nF  
1kΩ  
33nF  
5
6
TO FREQ.  
COUNTER  
ADE7752B  
RB  
825Ω  
CF  
1
IAN  
22pF  
10MHz  
22pF  
K8  
20  
CLKOUT  
PS2501-1  
7
8
IBP  
IBN  
ICP  
ICN  
SAME AS  
IAP, IAN  
19  
CLKIN  
S0  
21  
22  
18  
9
SAME AS  
IAP, IAN  
V
S1  
DD  
10  
1kΩ  
SCF  
1MΩ  
1kΩ  
16  
VAP  
33nF  
220V  
REF  
12  
4
IN/OUT  
REVP  
SAME AS VAP  
SAME AS VAP  
15  
14  
VBP  
VCP  
100nF  
NOT  
10μF  
CONNECTED  
VN AGND DGND  
13 11  
2
1kΩ  
33nF  
Figure 14. Test Circuit for Performance Curves  
Rev. PrA | Page 12 of 27  
Preliminary Technical Data  
THEORY OF OPERATION  
ADE7752B  
The six signals from the current and voltage transducers are  
digitized with ADCs. These ADCs are 16-bit second-order ∑-Δ  
with an oversampling rate of 833 kHz. This analog input  
structure greatly simplifies transducer interface by providing a  
wide dynamic range and bipolar input for direct connection to  
the transducer. High-pass filters in the current channels remove  
the dc component from the current signals. This eliminates any  
inaccuracies in the active power calculation due to offsets in the  
voltage or current signals (see the HPF and Offset Effects  
section).  
The low frequency output of the ADE7752B is generated by  
accumulating the total active power information. This low  
frequency inherently means a long accumulation time between  
output pulses. The output frequency is therefore proportional to  
the average active power. This average active power information  
can, in turn, be accumulated (for example, by a counter) to  
generate active energy information. Because of its high output  
frequency and therefore shorter integration time, the CF output  
is proportional to the instantaneous active power. This pulse is  
useful for system calibration purposes that would take place  
under steady load conditions.  
The active power calculation is derived from the instantaneous  
power signal. The instantaneous power signal is generated by a  
direct multiplication of the current and voltage signals of each  
phase. In order to extract the active power component, the dc  
component, the instantaneous power signal is low-pass filtered  
on each phase. Figure 15 illustrates the instantaneous active  
power signal and shows how the active power information can  
be extracted by low-pass filtering the instantaneous power  
signal. This method is used to extract the active power  
information on each phase of the polyphase system. The total  
active power information is then obtained by adding the  
individual phase active power. This scheme correctly calculates  
active power for nonsinusoidal current and voltage waveforms  
at all power factors. All signal processing is carried out in the  
digital domain for superior stability over temperature and time.  
POWER FACTOR CONSIDERATIONS  
Low-pass filtering, the method used to extract the active power  
information from the individual instantaneous power signal, is  
still valid when the voltage and current signals of each phase are  
not in phase. Figure 16 displays the unity power factor  
condition and a displacement power factor (DPF) = 0.5, that is,  
current signal lagging the voltage by 60°, for one phase of the  
polyphase. Assuming that the voltage and current waveforms  
are sinusoidal, the active power component of the instantaneous  
power signal (the dc term) is given by  
V ×1  
2
×cos  
(
60°  
)
(1)  
p(t) = i(t) × v(t)  
WHERE:  
V × I  
V × I  
2
v(t) = V × cos (ωt)  
i(t) = I × cos (ωt)  
p(t) = V × I  
V × I  
2
{1+ cos (2ωt)}  
2
INSTANTANEOUS  
POWER SIGNAL - p(t)  
TIME  
INSTANTANEOUS  
ACTIVE POWER SIGNAL  
VA × IA + VB × IB +  
VC × IC  
2
HPF  
ADC  
ABS  
|X|  
IAP  
IAN  
INSTANTANEOUS  
TOTAL  
POWER SIGNAL  
LPF  
LPF  
LPF  
MULTIPLIER  
ADC  
VAP  
DIGITAL-TO-  
FREQUENCY  
HPF  
ADC  
F1  
F2  
IBP  
IBN  
Σ
Σ
Σ
|X|  
MULTIPLIER  
ADC  
DIGITAL-TO-  
FREQUENCY  
VBP  
CF  
HPF  
ADC  
ICP  
ICN  
|X|  
MULTIPLIER  
ADC  
VCP  
VN  
Figure 15. Signal Processing Block Diagram  
Rev. PrA | Page 13 of 27  
ADE7752B  
Preliminary Technical Data  
This is the correct active power calculation.  
i
(
t
)
= IO  
+
2 ×  
VnI × sin  
(
nωt βn  
)
(3)  
INSTANTANEOUS  
POWER SIGNAL  
INSTANTANEOUS  
ACTIVE POWER SIGNAL  
n=0  
where:  
i(t) is the instantaneous current.  
IO is the dc component.  
V× I  
2
In is the rms value of current harmonic n.  
βn is the phase angle of the current harmonic.  
0V  
CURRENT  
VOLTAGE  
Using Equations 2 and 3, the active power, P, can be expressed  
in terms of its fundamental active power (P1) and harmonic  
active power (PH).  
INSTANTANEOUS  
POWER SIGNAL  
INSTANTANEOUS  
ACTIVE POWER SIGNAL  
P = P1 + PH  
V× I  
2
× cos(60°)  
where:  
0V  
P = V1 × I1 cos φ1  
1
(4)  
φ1 = α1 β1  
VOLTAGE  
CURRENT  
60°  
Figure 16. DC Component of Instantaneous Power Signal  
PH  
=
Vn × In cos φn  
(5)  
n=1  
φn = αn βn  
NONSINUSOIDAL VOLTAGE AND CURRENT  
The active power calculation method also holds true for non-  
sinusoidal current and voltage waveforms. All voltage and  
current waveforms in practical applications have some  
harmonic content. Using the Fourier Transform, instantaneous  
voltage and current waveforms can be expressed in terms of  
their harmonic content  
As can be seen from Equation 5, a harmonic active power  
component is generated for every harmonic, provided that  
harmonic is present in both the voltage and current waveforms.  
The power factor calculation has been shown to be accurate in  
the case of a pure sinusoid. Therefore, the harmonic active  
power also correctly accounts for power factor since harmonics  
are made up of a series of pure sinusoids. A limiting factor on  
harmonic measurement is the bandwidth. On the ADE7752B,  
the bandwidth of the active power measurement is 14 kHz with  
a master clock frequency of 10 MHz.  
v
(
t
)
= Vo + 2 ×  
Vn × sin  
(nωt + αn  
)
(2)  
n =0  
where:  
v(t) is the instantaneous voltage.  
VO is the average value.  
Vn is the rms value of voltage harmonic n.  
and αn is the phase angle of the voltage harmonic.  
Rev. PrA | Page 14 of 27  
Preliminary Technical Data  
ADE7752B  
ANALOG INPUTS  
CURRENT CHANNELS  
VOLTAGE CHANNELS  
The voltage outputs from the current transducers are connected  
to the ADE7752B current channels, which are fully differential  
voltage inputs. IAP, IBP, and ICP are the positive inputs for IAN,  
IBN, and ICN, respectively.  
The output of the line voltage transducer is connected to the  
ADE7752B at this analog input. Voltage channels are a pseudo-  
differential voltage input. VAP, VBP, and VCP are the positive  
inputs with respect to VN.  
The maximum peak differential signal on the current channel  
should be less than ±500 mV (353 mV rms for a pure sinusoidal  
signal) for the specified operation.  
The maximum peak differential signal on the voltage channel is  
±500 mV (353 mV rms for a pure sinusoidal signal) for speci-  
fied operation.  
IAP–IAN  
Figure 18 illustrates the maximum signal levels that can be  
connected to the ADE7752B voltage channels.  
+500mV  
IAP  
IAN  
VAP–VN  
DIFFERENTIAL INPUT  
IA  
±500mV MAX PEAK  
+500mV  
V
CM  
VA P  
VN  
V
COMMON-MODE  
CM  
±25mV MAX  
DIFFERENTIAL INPUT  
VA  
±500mV MAX PEAK  
AGND  
–500mV  
V
CM  
VCM  
COMMON-MODE  
±25mV MAX  
Figure 17. Maximum Signal Levels, Current Channel  
AGND  
–500mV  
The maximum signal levels on IAP and IAN are shown in  
Figure 17. The maximum differential voltage between IAP and  
IAN is ±500 mV. The differential voltage signal on the inputs  
must be referenced to a common mode, for example, AGND.  
The maximum common-mode signal shown in Figure 17 is  
±25 mV.  
Figure 18. Maximum Signal Levels, Voltage Channel  
Voltage channels must be driven from a common-mode voltage,  
that is, the differential voltage signal on the input must be refer-  
enced to a common mode (usually AGND). The analog inputs  
of the ADE7752B can be driven with common-mode voltages of  
up to 25 mV with respect to AGND. However, best results are  
achieved using a common mode equal to AGND.  
Rev. PrA | Page 1± of 27  
ADE7752B  
Preliminary Technical Data  
TYPICAL CONNECTION DIAGRAMS  
CURRENT CHANNEL CONNECTION  
METER CONNECTIONS  
Figure 19 shows a typical connection diagram for the current  
channel (IA). A current transformer (CT) is the current trans-  
ducer selected for this example. Notice the common-mode  
voltage for the current channel is AGND and is derived by  
center tapping the burden resistor to AGND. This provides the  
complementary analog input signals for IAP and IAN. The CT  
turns ratio and burden resistor Rb are selected to give a peak  
differential voltage of ±500 mV at maximum load.  
In 3-phase service, two main power distribution services exist:  
3-phase 4-wire or 3-phase 3-wire. The additional wire in the  
3-phase 4-wire arrangement is the neutral wire. The voltage  
lines have a phase difference of ±120° (±2±/3 radians) between  
each other (see Equation 6).  
VA  
VB  
(
t
)
)
=
2 ×VA × cos  
(
ωlt  
)
2π  
3
(
t
= 2 ×V × cos ω t +  
(6)  
B
l
In theory it is better to center tap Rb; however, this requires  
very careful attention to the layout and matching of the resistors  
to ensure that the channels have the same resistance. A single  
resistor may be more practical and is a valid design choice.  
4π  
3
V C t = 2 ×V × cos ω t +  
( )  
C
l
where VA, VB, and VC represent the voltage rms values of the  
different phases.  
Rf  
IAP  
IAN  
CT  
The current inputs are represented by  
Cf  
Cf  
±500mV  
R
b
I A  
IB  
(
t
)
)
=
=
2 I A ×cos  
(
ωlt + φA  
)
2π  
3
IP  
PHASE NEUTRAL  
Rf  
(
t
2 IB ×cos ω t +  
+ φB  
(7)  
l
4π  
3
Figure 19. Typical Connection for Current Channels  
IC  
(
t
)
=
2 IC ×cos ω t +  
+ φC  
l
VOLTAGE CHANNELS CONNECTION  
where:  
Figure 20 shows two typical connections for the voltage chan-  
nel. The first option uses a potential transformer (PT) to pro-  
vide complete isolation from the main voltage. In the second  
option, the ADE7752B is biased around the neutral wire, and a  
resistor divider is used to provide a voltage signal proportional  
to the line voltage. Adjusting the ratio of Ra, Rb, and VR is a  
convenient way of carrying out a gain calibration on the meter.  
VR can be implemented using either a potentiometer or a  
binary weighted series of resistors. Either configuration works,  
however, the potentiometer is subject to noise over time. Two  
fixed value resistors can be used in place of VR to minimize the  
noise.  
IA, IB, and IC represent the rms value of the current of each  
phase.  
φA, φB, and φC represent the phase difference of the current and  
voltage channel of each phase.  
The instantaneous powers can then be calculated as follows:  
PA(t) = VA(t) × IA(t)  
PB(t) = VB(t) × IB(t)  
PC(t) = VC(t) × IC(t)  
Then:  
PA  
(
t
)
)
= VA × IA × cos  
(
φA  
)
VA × IA ×cos  
(
2ωlt + φA  
)
4π  
3
(8)  
PB  
(
t
= VB × IB × cos  
(φB  
)
)
VB × IB ×cos 2ω t +  
+ φB  
l
VAP  
VN  
Rf  
PT  
Cf  
Cf  
8π  
3
PC  
(
t
)
= VC × IC × cos  
(φC  
VC × IC ×cos 2ω t +  
+ φC  
±500mV  
l
Rf  
As shown in Equation 8, in the ADE7752B, the active power  
AGND  
calculation per phase is made when current and voltage inputs  
of one phase are connected to the same channel (A, B, or C).  
Then the summation of each individual active power calcula-  
tion gives the total active power information, P(t) = PA(t) +  
PB(t) + PC(t).  
PHASE NEUTRAL  
Cf  
Ra  
*
Rb  
*
VAP  
VN  
±500mV  
VR  
*
Rf  
Cf  
PHASE NEUTRAL  
Ra >> Rf + VR; Rb + VR = Rf  
*
*
Figure 20. Typical Connections for Voltage Channels  
Rev. PrA | Page 16 of 27  
Preliminary Technical Data  
ADE7752B  
Figure 21 shows the connections of the ADE7752B analog  
inputs with the power lines in a 3-phase 3-wire delta service.  
Figure 22 shows the connections of the ADE7752B analog  
inputs with the power lines in a 3-phase 4-wire Wye service.  
Cf  
Cf  
Ra*  
Ra*  
Rb*  
Rb*  
VAP  
IAP  
VR*  
VAP  
VR*  
IAP  
IAN  
Rb*  
CT  
IAN  
Rb*  
CT  
ANTIALIASING  
FILTERS  
ANTIALIASING  
FILTERS  
CT  
PHASE A  
PHASE A  
SOURCE  
Cf  
ANTIALIASING  
FILTERS  
Ra*  
PHASE B  
PHASE C  
PHASE C  
Rb*  
Rb*  
IBP  
IBN  
VBP  
LOAD  
SOURCE  
PHASE B  
VN  
Rf  
Cf  
VR*  
CT  
CT  
ANTIALIASING  
FILTERS  
ANTIALIASING  
FILTERS  
Cf  
Ra*  
Rb*  
Rb*  
Cf  
IBP  
IBN  
Ra*  
Rb*  
ICP  
LOAD  
ICN  
Rb*  
VR*  
VCP  
VR*  
VBP  
Rf  
Ra >> Rf + VR; Rb + VR = Rf  
*
*
VN  
Figure 21. 3-Phase 3-Wire Meter Connection with ADE7752B  
Ra >> Rf + VR; Rb + VR = Rf  
*
*
CF  
Figure 22. 3-Phase 4-Wire Meter Connection with ADE7752B  
Note that only two current inputs and two voltage inputs of the  
ADE7752B are used in this case. The active power calculated by  
the ADE7752B does not depend on the selected channels.  
Rev. PrA | Page 17 of 27  
ADE7752B  
Preliminary Technical Data  
POWER SUPPLY MONITOR  
The ADE7752B contains an on-chip power supply monitor. The  
power supply (VDD) is monitored continuously by the ADE7752B.  
At power up, when the supply is less than 4V ±2ꢀ and VREF is less  
than 1.9 V (typ), the outputs of the ADE7752B are inactive and  
the data path is held in reset. Once VDD is greater than 4V ±2ꢀ  
and VREF is greater than 1.9 V (typ), the chip is active and energy  
accumulation begins. At power-down, when VDD falls below 4 V  
or VREF falls below 1.9 V (typ), the data path is again held in reset.  
This implementation ensures correct device operation at power-  
up and at power-down. The power supply monitor has built-in  
hysteresis and filtering. This gives a high degree of immunity to  
false triggering due to noisy supplies.  
V
V
DD  
5V  
4V  
REF  
2.4V  
1.9V  
0V  
INTERNAL  
RESET  
INACTIVE  
ACTIVE  
INACTIVE  
The power supply and decoupling for the part should be such  
that the ripple at VDD does not exceed ±5ꢀ as specified for  
normal operation.  
Figure 23. On-Chip Power Supply Monitor  
Rev. PrA | Page 18 of 27  
ADE7752B  
Preliminary Technical Data  
HPF AND OFFSET EFFECTS  
Figure 24 shows the effect of offsets on the active power  
calculation. An offset on the current channel and voltage  
channel contributes a dc component after multiplication as  
shown in Figure 24. Since this dc component is extracted by the  
LPF and is used to generate the active power information for  
each phase, the offsets can contribute a constant error to the  
total active power calculation. The HPF in the current channels  
avoids this problem easily. By removing the offset from at least  
one channel, no error component can be generated at dc by the  
multiplication. Error terms at cos(ωt) are removed by the LPF  
and the digital-to-frequency conversion (see the Digital-to-  
Frequency Conversion) section.  
The ADE7752B is phase compensated up to 1 kHz as shown. This  
ensures correct active harmonic power calculation even at low  
power factors.  
{
V cos  
V × I  
(
ωt  
)
+VOS  
}
×
{
I cos  
(
ωt  
)
+ IOS  
ωt  
}
=
(9)  
+ IOS ×V cos ωt  
) ( )  
+ VOS × IOS + VOS × I cos  
(
2
V × I  
+
× cos 2ωt  
( )  
2
Figure 25. Phase Error between Channels (0 Hz to 1 kHz)  
DC COMPONENT (INCLUDING ERRORTERM)  
IS EXTRACTED BYTHE LPF FOR REAL  
POWER CALCULATION  
V
× I  
OS  
OS  
V × I  
2
I
× V  
OS  
V
× I  
OS  
2ω  
FREQUENCY – RAD/S  
ω
0
Figure 24. Effect of Channel Offset on the Active Power Calculation  
The HPF in the current channels has an associated phase response  
that is compensated for on-chip. Figure 25 and Figure 26 show the  
phase error between channels with the compensation network.  
Figure 26. Phase Error Between Channels (40 Hz to 70 Hz)  
Rev. PrA | Page 1ꢀ of 27  
ADE7752B  
Preliminary Technical Data  
DIGITAL-TO-FREQUENCY CONVERSION  
After multiplication, the digital output of the low-pass filter  
contains the active power information of each phase. However,  
since this LPF is not an ideal brick wall filter implementation, the  
output signal also contains attenuated components at the line  
frequency and its harmonics, that is, cos(hωt), where h = 1, 2, 3 ….  
The average value of a sinusoidal signal is zero. Thus, the  
frequency generated by the ADE7752B is proportional to the  
average active power. Figure 27 shows the digital-to-frequency  
conversion for steady load conditions, that is, constant voltage  
and current.  
The magnitude response of the filter is given by  
1
The frequency output CF varies over time, even under steady load  
conditions (see Figure 27). This frequency variation is primarily  
due to the cos(2ωt) components in the instantaneous active power  
signal. The output frequency on CF can be up to 160× higher than  
the frequency on F1 and F2. The higher output frequency is  
generated by accumulating the instantaneous active power signal  
over a much shorter time, while converting it to a frequency. This  
shorter accumulation period means less averaging of the cos(2ωt)  
component. Therefore, some of this instantaneous power signal  
passes through the digital-to-frequency conversion.  
|H  
(
f
)
| =  
(10)  
2
f
⎧ ⎫  
1 +  
⎨ ⎬  
8
⎩ ⎭  
where the −3 dB cutoff frequency of the low-pass filter is 8 Hz.  
For a line frequency of 50 Hz, this would give an attenuation of  
the 2ω(100 Hz) component of approximately −22 dB. The  
dominating harmonic is twice the line frequency, that is,  
cos(2ωt), due to the instantaneous power signal. Figure 27  
shows the instantaneous active power signal at the output of the  
CF, which still contains a significant amount of instantaneous  
power information, cos(2ωt).  
Where CF is used for calibration purposes, the frequency counter  
should average the frequency to remove the ripple and obtain a  
stable frequency. If CF is being used to measure energy, for  
example, in a microprocessor-based application, the CF output  
should also be averaged to calculate power. Because the outputs F1  
and F2 operate at a much lower frequency, significant averaging of  
the instantaneous active power signal is carried out. The result is a  
greatly attenuated sinusoidal content and a virtually ripple-free  
frequency output on F1 and F2, which are used to measure energy  
in a stepper-motor based meter.  
This signal is then passed to the digital-to-frequency converter  
where it is integrated (accumulated) over time to produce an  
output frequency. This accumulation of the signal suppresses or  
averages out any non-dc component in the instantaneous active  
power signal.  
ABS  
VA  
LPF  
MULTIPLIER  
IA  
|X|  
|X|  
F1  
DIGITAL-TO-  
FREQUENCY  
F1  
Σ
Σ
VB  
MULTIPLIER  
F2  
LPF  
TIME  
CF  
Σ
DIGITAL-TO-  
FREQUENCY  
IB  
CF  
VC  
TIME  
LPF  
MULTIPLIER  
IC  
|X|  
V× I  
2
LPF TO EXTRACT  
REAL POWER  
(DC TERM)  
cos(2ωt)  
ATTENUATED BY LPF  
2ω  
FREQUENCY – RAD/S  
ω
0
INSTANTANEOUS REAL POWER SIGNAL  
(FREQUENCY DOMAIN)  
Figure 27. Active Power-to-Frequency Conversion  
Rev. PrA | Page 25 of 27  
Preliminary Technical Data  
ADE7752B  
MODE SELECTION OF THE SUM OF THE THREE  
ACTIVE ENERGIES  
POWER MEASUREMENT CONSIDERATIONS  
Calculating and displaying power information always have some  
associated ripple that depends on the integration period used in the  
MCU to determine average power as well as the load. For example,  
at light loads, the output frequency can be 10 Hz. With an integra-  
tion period of two seconds, only about 20 pulses are counted. The  
possibility of missing one pulse always exists since the ADE7752B  
output frequency is running asynchronously to the MCU timer.  
This would result in a 1-in-20 or 5ꢀ error in the power measure-  
ment. To remedy this, an appropriate integration time should be  
considered to achieve the desired accuracy.  
The ADE7752B can be configured to execute the arithmetic  
sum of the three active energies, Wh = WhΦA + Wh B + Wh ,  
C
Φ
Φ
or the sum of the absolute value of these energies, Wh = |WhΦ  
|
A
+ |Wh | + |Wh |. The selection between the two modes can  
B
C
Φ
Φ
be made by setting the  
pin. Logic high and logic low  
ABS  
applied on the  
pin correspond to the arithmetic sum and  
ABS  
the sum of absolute values, respectively.  
When the sum of the absolute values is selected, the active  
energy from each phase is always counted positive in the total  
active energy. It is particularly useful in 3-phase 4-wire  
instillation where the sign of the active power should always be  
the same. If the meter is misconnected to the power lines, that  
is, CT connected in the wrong direction then the total active  
energy recorded without this solution can be reduced by two-  
thirds.  
The sum of the absolute values assures that the active energy  
recorded represents the actual active energy delivered.  
Regardless of the mode selected using this pin, the reverse  
power pin still detects when negative power is present on the  
sum of the three phase inputs.  
Rev. PrA | Page 21 of 27  
ADE7752B  
Preliminary Technical Data  
TRANSFER FUNCTION  
FREQUENCY OUTPUTS F1 AND F2  
Example 1  
Thus, if full-scale differential dc voltages of +500 mV are  
applied to VA, VB, VC, IA, IB, and IC, respectively (500 mV is  
the maximum differential voltage that can be connected to  
current and voltage channels), then the expected output  
frequency is calculated as follows:  
The ADE7752B calculates the product of six voltage signals (on  
current channel and voltage channel) and then low-pass filters  
this product to extract active power information. This active  
power information is then converted to a frequency. The  
frequency information is output on F1 and F2 in the form of  
active high pulses. The pulse rate at these outputs is relatively  
low, for example, 2.01 Hz maximum for ac signals with SCF =  
S0 = 0; S1 = 1 (see Table 6). This means that the frequency at  
these outputs is generated from active power information  
accumulated over a relatively long period. The result is an  
output frequency that is proportional to the average active  
power. The averaging of the active power signal is implicit to  
the digital-to-frequency conversion. The output frequency or  
pulse rate is related to the input voltage signals by the following  
equation:  
F1–7 = 0.58 Hz, SCF = S0 = S1 = 1  
VAN = VBN = VCN = IA = IB = IC  
= 500 mV dc = 0.5 V(rms of dc = dc)  
VREF = 2.4 V (nominal reference value)  
Note that if the on-chip reference is used, actual output  
frequencies can vary from device to device due to reference  
tolerance of ±8ꢀ.  
6.181× 0.5× 0.5× 0.58  
Freq = 3×  
= 0.467 Hz  
(12)  
2
2.4  
6.181×  
(V  
× I + V × I + V × I  
)
× F  
AN  
A
BN  
B
CN  
C 17  
Example 2  
Freq =  
(11)  
2
V
REF  
In this example, with ac voltages of ±500 mV peak applied to  
the voltage channels and current channels, the expected output  
frequency is calculated as follows:  
where:  
Freq = output frequency on F1 and F2 (Hz).  
VAN, BN, and VCN = differential rms voltage signal on voltage  
channels (V).  
IA, IB, and IC = differential rms voltage signal on current channels  
(V).  
F17 = 0.58 Hz, SCF = S0 = S1 =1  
VAN = VBN = VCN = IA = IB = IC  
V
(13)  
0.5  
2
= 500 mV peak AC =  
VREF = 2.4 V  
Vrms  
V
REF = the reference voltage (2.4 V ±8ꢀ) (V).  
(
nominal reference value  
)
F1–7 = one of seven possible frequencies selected by using the  
Note that if the on-chip reference is used, actual output fre-  
quencies can vary from device to device due to reference  
tolerance of ±8ꢀ.  
logic inputs SCF, S0, and S1 (see Table 5).  
Table 5. F1–7 Frequency Selection1  
SCF  
S1  
S0  
F1–7 (Hz)  
2.35  
6.181× 0.5× 0.5× 0.58  
Freq = 3×  
= 0.233 Hz  
(14)  
2
5
5
5
2 × 2 × 2.4  
1
5
5
4.61  
As can be seen from these two example calculations, the maximum  
output frequency for ac inputs is always half of that for dc input  
signals. The maximum frequency also depends on the number of  
phases connected to the ADE7752B. In a 3-phase 3-wire delta ser-  
vice, the maximum output frequency is different from the maxi-  
mum output frequency in a 3-phase 4-wire Wye service. The  
reason is that there are only two phases connected to the analog  
inputs, but also that in a delta service, the current channel input  
and voltage channel input of the same phase are not in phase in  
normal operation.  
5
1
5
1
5
1
5
5
1
1
1
1
1
1
5
5
1
1
1.1±  
4.61  
±.22  
1.1±  
5.±8  
5.±8  
1 F1–7 is a fraction of the master clock and therefore varies if the specified  
CLKIN frequency is altered.  
Rev. PrA | Page 22 of 27  
Preliminary Technical Data  
ADE7752B  
Example 3  
Note that if the on-chip reference is used, actual output  
frequencies can vary from device to device due to reference  
tolerance of ±8ꢀ.  
In this example, the ADE7752B is connected to a 3-phase 3-  
wire delta service as shown in Figure 21. The total active energy  
calculation processed in the ADE7752B can be expressed as  
6.181× 0.5× 0.5× 0.60  
3
Freq = 2 ×  
×
= 0.139 Hz  
(20)  
2
2
2 × 2 × 2.4  
Total Active Power = (VA VC) × IA + (VB VC) × IB  
Table 6 shows a complete listing of all maximum output  
frequencies when using all three channel inputs.  
where:  
VA, VB, and VC represent the voltage on phase A, phase B, and  
phase C, respectively.  
IA and IB represent the current on phase A and phase B,  
Table 6: Maximum Output Frequency on F1 and F2  
Maximum  
Maximum  
Frequency for AC  
Inputs (Hz)  
Frequency for DC  
Inputs (Hz)  
respectively.  
SCF  
5
S1  
5
S0  
5
5.ꢀ3  
1.86  
5.46  
1.86  
2.15  
5.46  
5.23  
5.23  
1.8±  
3.71  
5.ꢀ3  
3.71  
4.25  
5.ꢀ3  
5.47  
5.47  
As the voltage and current inputs respect Equations 5 and 6, the  
total active power (P) is  
1
5
1
5
1
5
1
5
1
5
5
1
1
1
1
1
1
5
5
1
1
P =  
(
VA VC  
)
(
IAP IAN  
)
+
(
VB VC  
)
×
(
IBP IBN  
)
4π  
3
P = 2 ×VA × cos  
(
ωlt  
)
2 ×VC × cos ω t +  
l
(15)  
×
+
2 × I A ×cos  
(
ωlt  
)
2π  
4π  
3
2 ×VB ×cos ω t +  
v 2 ×V × cos ω t +  
C
l
l
3
2π  
3
×
2 × IB × cos ω t +  
l
FREQUENCY OUTPUT CF  
The pulse output calibration frequency (CF) is intended for use  
during calibration. The output pulse rate on CF can be up to 64×  
the pulse rate on F1 and F2. Table 7 shows how the two  
frequencies are related, depending on the states of the logic  
inputs S0, S1, and SCF. Because of its relatively high pulse rate,  
the frequency at this logic output is proportional to the  
instantaneous active power. As is the case with F1 and F2, the  
frequency is derived from the output of the low-pass filter after  
multiplication. However, since the output frequency is high, this  
active power information is accumulated over a much shorter  
time. Thus, less averaging is carried out in the digital-to-  
frequency conversion. The CF output is much more responsive  
to power fluctuations with much less averaging of the active  
power signal (see Figure 15).  
For simplification, assume that ΦA = ΦB = ΦC = 0 and  
VA = VB = VC = V. The preceding equation becomes  
2π  
3
2π  
3
P = 2×V ×IA ×sin  
×sin ω t +  
×cos  
(ωlt  
)
l
(16)  
(17)  
π
3
2π  
3
+ 2×V ×IB ×sin  
×sin(ωl t + π  
)
×cos ω t +  
l
P then becomes  
2π  
3
2π  
3
P = VAN × I A × sin  
+ sin 2ω t +  
l
π
π
3
+VBN × IB × sin  
+ sin 2ω t +  
l
3
where:  
Table 7. Maximum Output Frequency on CF  
VAN = V × sin(2±/3).  
VBN = V × sin(±/3).  
SCF  
S1 S0 F1–7 (Hz)  
CF Maximum for AC Signals (Hz)  
16 × F1, F2 = 14.88  
8 × F1, F2 = 14.88  
5
1
5
5
5
5
1
1
1
1
5
5
1
1
5
5
1
1
2.3  
As the LPF on each channel eliminates the 2ωl component of  
the equation, the active power measured by the ADE7752B is  
4.61  
1.1±  
4.61  
±.22  
1.1±  
5.±8  
5.±8  
5
1
5
1
32 × F1, F2 = 14.88  
16 × F1, F2 = 2ꢀ.76  
165 × F1, F2 = 336  
16 × F1, F2 = 7.36  
3
2
3
2
P = VAN × I A ×  
+VBN × IB ×  
(18)  
If full-scale ac voltage of ±500 mV peak is applied to the voltage  
channels and current channels, the expected output frequency  
is calculated as follows:  
5
32 × F1, F2 = 7.36  
1
16 × F1, F2 = 3.68  
F
= 0.60Hz, SCF = S0 = S1 = 1  
17  
0.5  
2
VAN = VBN = IA = IB = IC = 500 mVpeak ac =  
Vrms  
(19)  
VCN = IC = 0  
VREF = 2.4V nominal reference value  
Rev. PrA | Page 23 of 27  
Preliminary Technical Data  
ADE7752B  
SELECTING A FREQUENCY FOR AN ENERGY METER APPLICATION  
As shown in Table 5, the user can select one of seven  
frequencies. This frequency selection determines the maximum  
frequency on F1 and F2. These outputs are intended to be used  
to drive the energy register (electromechanical or other). Since  
seven different output frequencies can be selected, the available  
frequency selection has been optimized for a 3-phase 4-wire  
service with a meter constant of 100 imp/kWhr and a  
maximum current of between 10 A and 100 A. Table 8 shows  
the output frequency for several maximum currents (IMAX) with  
a line voltage of 220 V (phase neutral). In all cases, the meter  
constant is 100 imp/kWhr.  
When selecting a suitable F1–7 frequency for a meter design, the  
frequency output at IMAX (maximum load) with a 100 imp/kWhr  
meter constant should be compared with Column 5 of Table 9. The  
frequency that is closest in Table 9 determines the best choice of  
frequency (F1–7). For example, if a 3-phase 4-wire Wye meter with a  
25 A maximum current is being designed, the output frequency on  
F1 and F2 with a 100 imp/kWhr meter constant is 0.46 Hz at 25 A  
and 220 V (see Table 8). Looking at Table 9, the closest frequency to  
0.46 Hz in Column 5 is 0.53 Hz. Therefore, F1–7 = 5.22 Hz is  
selected for this design.  
FREQUENCY OUTPUTS  
Table 8. F1 and F2 Frequency at 100 imp/kWhr  
Figure 2 shows a timing diagram for the various frequency  
outputs. The outputs F1 and F2 are the low frequency outputs  
that can be used to directly drive a stepper motor or electro-  
mechanical impulse counter. The F1 and F2 outputs provide  
two alternating high going pulses. The pulse width (t1) is set at  
120 ms, and the time between the rising edges of F1 and F2 (t3)  
is approximately half the period of F1 (t2). If, however, the  
period of F1 and F2 falls below 550 ms (1.81 Hz), the pulse  
width of F1 and F2 is set to half of their period. The maximum  
output frequencies for F1 and F2 are shown in Table 6.  
IMAX (A)  
F1 and F2 (Hz)  
15  
2±  
45  
65  
85  
155  
5.18  
5.46  
5.73  
1.15  
1.47  
1.83  
The F1–7 frequencies allow complete coverage of this range of  
output frequencies on F1 and F2. When designing an energy  
meter, the nominal design voltage on the voltage channels  
should be set to half scale to allow for calibration of the meter  
constant. The current channel should also be no more than half  
scale when the meter sees maximum load. This allows  
overcurrent signals and signals with high crest factors to be  
accommodated. Table 9 shows the output frequency on F1 and  
F2 when all six analog inputs are half scale.  
The high frequency CF output is intended to be used for  
communications and calibration purposes. CF produces a 90 ms-  
wide active high pulse (t4) at a frequency proportional to active  
power. The CF output frequencies are given in Table 7. As in the  
case of F1 and F2, if the period of CF (t5) falls below 190 ms, the CF  
pulse width is set to half the period. For example, if the CF  
frequency is 20 Hz, the CF pulse width is 25 ms.  
Table 9. F1 and F2 Frequency with Half-Scale AC Inputs  
Frequency on F1 and F2  
F1–7 (Hz) (Half-Scale AC Inputs) (Hz)  
NO LOAD THRESHOLD  
SCF S1 S0  
The ADE7752B includes no load threshold and start-up current  
circuitry features that eliminate any creep effects in the meter.  
The circuit is designed to issue a minimum output frequency.  
Any load generating a frequency lower than this minimum  
output frequency does not cause a pulse to be issued on F1, F2, or  
CF. The no-load threshold is determined by the sum of all phases.  
The minimum output frequency is given as 0.0075ꢀ of the full-  
scale output frequency for each of the F1–7 frequency selections, or  
approximately 0.0029ꢀ of the F1–7 frequency (see Table 10). For  
example, for an energy meter with a 100 imp/kWhr meter  
constant using F1–7 (4.61 Hz), the minimum output frequency at  
F1 or F2 would be 13.35 × 10–5 Hz. This would be 2.13 × 10–3 Hz  
at CF (16 × F1 Hz). In this example, the no load threshold would  
be equivalent to 4.8 W of load or a start-up current of 20.03 mA  
at 240 V.  
5
1
5
1
5
1
5
1
5
5
5
5
1
1
1
1
5
5
1
1
5
5
1
1
2.3  
5.23  
5.46  
5.12  
5.46  
5.±3  
5.12  
5.56  
5.56  
4.61  
1.1±  
4.61  
±.22  
1.1±  
5.±8  
5.±8  
Rev. PrA | Page 24 of 27  
Preliminary Technical Data  
ADE7752B  
Table 10. CF, F1, and F2 Minimum Frequency at No Load  
Threshold  
SCF S1 S0 F1, F2 Minimum (Hz) CF Minimum (Hz)  
NEGATIVE POWER INFORMATION  
The ADE7752B detects when total power, calculated as the sum  
of the three phases, is negative. This mechanism can detect an  
incorrect connection of the meter or generation of negative  
active energy. The REVP pin output goes active high when  
negative power is detected on the sum of the three phase inputs.  
If positive active power is detected on the sum of three phases,  
then REVP pin output is low.  
5
1
5
1
5
1
5
1
5
5
5
5
1
1
1
1
5
5
1
1
5
5
1
1
6.ꢀ4E − 5±  
1.3ꢀE − 54  
3.47E − 5±  
1.3ꢀE − 54  
1.±8E − 54  
3.47E − 5±  
1.7±E − 5±  
1.7±E − 5±  
1.11E − 53  
1.11E − 53  
1.11E − 53  
2.23E − 53  
2.±2E − 52  
±.±±E − 54  
±.65E − 54  
2.85E − 54  
The REVP pin output changes state at the same time as a pulse  
is issued on CF. If the sum of the phases measure negative  
power, then the REVP pin output stays high until the sum of the  
phases measures positive power.  
Rev. PrA | Page 2± of 27  
ADE7752B  
Preliminary Technical Data  
OUTLINE DIMENSIONS  
15.60 (0.6142)  
15.20 (0.5984)  
24  
1
13  
12  
7.60 (0.2992)  
7.40 (0.2913)  
10.65 (0.4193)  
10.00 (0.3937)  
2.65 (0.1043)  
2.35 (0.0925)  
0.75 (0.0295)  
0.25 (0.0098)  
× 45°  
0.30 (0.0118)  
0.10 (0.0039)  
8°  
0°  
1.27 (0.0500)  
BSC  
SEATING  
PLANE  
0.51 (0.020)  
0.31 (0.012)  
1.27 (0.0500)  
0.40 (0.0157)  
COPLANARITY  
0.10  
0.33 (0.0130)  
0.20 (0.0079)  
COMPLIANT TO JEDEC STANDARDS MS-013-AD  
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS  
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR  
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.  
Figure 28. 24-Lead Standard Small Outline Package [SOIC_W]  
Wide Body  
(RW-24)  
Dimensions shown in millimeters and (inches)  
ORDERING GUIDE  
Model  
ADE77±2BARWZ1  
ADE77±2BARWZ-RL1  
ADE77±2BARW  
Package Description  
Package Option  
28-Lead Standard Small Outline Package [SOIC_W]  
28-Lead Standard Small Outline Package [SOIC_W]  
28-Lead Standard Small Outline Package [SOIC_W]  
28-Lead Standard Small Outline Package [SOIC_W]  
ADE77±2B Evaluation Board  
RW-282  
RW-28 on 13" Reels  
RW-28  
RW-28 on 13" Reels  
ADE77±2BARW-RL  
EVAL-ADE77±2BEB  
1 Z = Pb-free part.  
2 RW = small outline wide body package in tubes.  
Rev. PrA | Page 26 of 27  
Preliminary Technical Data  
NOTES  
ADE7752B  
©
2006 Analog Devices, Inc. All rights reserved. Trademarks and  
registered trademarks are the property of their respective owners.  
PR05905-0-1/06(PrA)  
Rev. PrA | Page 27 of 27  

相关型号:

ADE7752BARW-RL

Polyphase Energy Metering IC with Pulsed Output
ADI

ADE7752BARWZ

Polyphase Energy Metering IC with Pulsed Output
ADI

ADE7752BARWZ-RL

Polyphase Energy Metering IC with Pulsed Output
ADI

ADE7752_15

Polyphase Energy Metering IC with Pulse Output
ADI

ADE7753

Active and Apparent Energy Metering IC with di/dt sensor interface
ADI

ADE7753ARS

Active and Apparent Energy Metering IC with di/dt sensor interface
ADI

ADE7753ARSRL

Active and Apparent Energy Metering IC with di/dt sensor interface
ADI

ADE7753ARSZ

Single-Phase Multifunction Metering IC with di/dt Sensor Interface
ADI

ADE7753ARSZRL

Single-Phase Multifunction Metering IC with di/dt Sensor Interface
ADI

ADE7753_10

Single-Phase Multifunction Metering IC with di/dt Sensor Interface
ADI

ADE7754

Poly-phase Multi-Function Energy Metering IC with Serial Port
ADI

ADE7754AR

Poly-phase Multi-Function Energy Metering IC with Serial Port
ADI