5B37-T [ADI]

Isolated Thermocouple Input; 隔离热电偶输入
5B37-T
型号: 5B37-T
厂家: ADI    ADI
描述:

Isolated Thermocouple Input
隔离热电偶输入

文件: 总8页 (文件大小:691K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Isolated Thermocouple Input  
5B37  
FEATURES  
Interfaces, amplifies and filters J, K, T, E, R, S, B, N, and C-type  
Thermocouple.  
Generates an isolated and protected precision output of 0 to  
+5V.  
Module circuitry can withstand 240v rms at the input screw-  
terminals.  
All 5B37 series modules are mix-and-match and Hot  
Swappable.  
APPLICATIONS  
Figure 1. 5B37 Functional Block Diagram  
Industrial signal conditioning  
Industrial signal isolation  
Industrial signal filtering  
There are also a number of backplanes and mounting sockets  
which provide a complete signal conditioning solution for end  
users. Each backplane incorporates screw terminals for field  
wiring inputs and outputs and cold junction sensors for  
thermocouple applications.  
PRODUCT OVERVIEW  
These signal conditioners are designed to provide an easy and  
convenient solution to signal conditioning problems of both  
designers and end users in measurement and control  
applications. Typical uses include microcomputer-based  
measurement systems, standard data acquisition systems,  
programmable controllers, analog recorders and dedicated  
control systems. The 5 B series modules are ideally suited to  
applications where monitoring and control of temperature,  
pressure, flow, rotation and other analog signals are required.  
The 5B Series represents an innovative generation of low cost,  
high performance plug-in signal conditioners. Designed for  
industrial applications, these modules incorporate highly  
reliable transformer-based isolation and automated surface-  
mount manufacturing technology. They are compact,  
economical components whose performance exceeds that  
available from more expensive devices. Combining 1500 V rms  
continuous isolation, +0.05% calibrated accuracy, small size and  
low cost, the 5B Series is an attractive alternative to expensive  
signal conditioners and in-house designs  
The 5B Series modules and backplanes are approved by Factory  
Mutual (FM) and the 5B Series modules are approved by the  
Canadian Standards Association (CSA) for use in Class 1,  
Division 2, Groups A, B, C, and D locations. These approvals  
certify that the 5B Series is suitable for use in locations where a  
hazardous concentration of flammable gas may exist only under  
fault conditions of operation. Equipment of this category is  
called “nonincendive” and they need no special enclosures or  
other physical safeguards.  
All modules are potted and identical in pin-out and size (2.27” x  
2.32” x 0.595”). They can be mixed and matched, permitting  
users to address their exact needs, and may be “hot swapped  
without disturbing field wiring or power. The isolated input  
modules provide 0 to +5V or +5V outputs and accept J, K, T, E,  
R, S, N, or B type thermocouples.  
These modules feature complete signal conditioning functions  
including 240 V rms input protection, filtering, chopper  
stabilized low drift +1 uV/oC amplification, 1500 V rms  
isolation, and sensor excitation when required.  
The 5B series modules and backplanes have been tested and  
passed the stringent heavy industrial requirements of the  
European Union’s electromagnetic compatibility (ENC)  
directive – EN50082-1 and EN50081-2. When used according  
to installation directions (refer to 5B series User Manual), any  
errors caused by EMI/RFI interference will be less than 0.1% of  
the full scale 5B measurement range for field strengths up to 10  
V/M and frequencies up to 1 GHz.  
All modules feature excellent common mode rejection and  
meet industrial transient surge withstand specifications.  
FUNCTIONAL BLOCK DIAGRAM  
Rev. 0  
Information furnished by Analog Devices is believed to be accurate and reliable.  
However, no responsibility is assumed by Analog Devices for its use, nor for any  
infringements of patents or other rights of third parties that may result from its use.  
Specifications subject to change without notice. No license is granted by implication  
or otherwise under any patent or patent rights of Analog Devices. Trademarks and  
registered trademarks are the property of their respective companies.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700  
Fax: 781.326.8703  
www.analog.com  
© 2004 Analog Devices, Inc. All rights reserved.  
5B37  
GENERAL DESCRIPTION  
optionally factory-set to meet custom needs. This allows  
suppression of a zero-scale input value many times larger than  
the total span for precise expanded-scale measurements.  
The 5B37 is a single-channel signal conditioning module that  
interfaces, amplifies and filters J, K, T, E, R, S, B, N, and C-type  
thermocouple and provides an isolated and protected precision  
output of 0 to +5V.  
Internal multi-pole low-pass filtering with a four Hz cutoff (-3  
dB) provides 60 dB of normal-mode rejection (noise on signal)  
and enhancement of common-mode rejection (noise on signal  
return) at 60 Hz, enabling accurate measurement of small  
signals in high electrical noise.  
Accurate and System-Ready – Internal cold-junction  
compensation largely corrects errors arising from parasitic  
thermocouples formed by thermocouple connection to the  
input screw terminals, providing an accuracy of +0.25oC @  
+25oC ambient temperature. The module generates a  
predictable upscale signal to indicate an open thermocouple, for  
a downscale response, connect a 47M, 0.25 W resistor across  
screw terminals 1 and 3.  
Signal isolation by transformer coupling uses a proprietary  
modulation technique for linear, stable and reliable  
performance. The differential input circuit on the field side is  
fully floating, eliminating the need for any input grounding. A  
demodulator on the computer side of the signal transformer  
recovers the original signal, which is then filtered and buffered  
to provide a low-noise, low-impedance output signal. The  
output common must be kept within 3 V of power common.  
The 5B37 protects the computer side from damage due to field-  
side over-voltage faults. All models withstand 240V rms at their  
input terminals without damage, thereby shielding computer-  
side circuitry from field-side over-voltage conditions. Further,  
the 5B37 is mix-and-match and hot-swappable with other 5B  
Series modules, so can be inserted or removed from any socket  
in the same backplane without disrupting system power.  
A series output switch eliminates the need for external  
multiplexing in many applications. The switch is turned on by  
an active-low enable input. If the switch is to be on at all times,  
the enable-input should be grounded to power common as it is  
on the 5B01 and 5B08 backplanes..  
A chopper-stabilized input amplifier provides low drift and  
stable gain. At the amplifier input a stable, laser-trimmed zero-  
scale input voltage is subtracted from the input signal to set the  
zero-scale value. For user convenience, the zero can be  
.
.
Figure 2  
Rev. 0 | Page 2 of 8  
5B37  
5B37 Models Available  
Model  
Input Type  
Type J  
Input Range  
Output Range  
0 V to +5 V  
0 V to +5 V  
0 V to +5 V  
0 V to +5 V  
0 V to +5 V  
0 V to +5 V  
0 V to +5 V  
0 V to +5 V  
*
5B37-J-01  
-100°C to +760°C (-148°F to +1400°F)  
-100°C to +1350°C (-148°F to +2462°F)  
-100°C to +400°C (-148°F to +752°F)  
0°C to +900°C (+32°F to +1652°F)  
0°C to +1750°C (+32°F to +3182°F)  
0°C to +1750°C (+32°F to +3182°F)  
0°C to +1800°C (+32°F to +3272°F)  
0°C to +1300°C (+32°F to +2372°F)  
*
5B37-K-02  
Type K  
Type T  
Type E  
Type R  
Type S  
Type B  
Type N  
5B37-T-03  
5B37-E-04  
5B37-R-05  
5B37-S-05  
5B37-B-06  
5B37-N-08  
5B37-Custom  
Type J, K, T, E, R,  
S, B, N, C  
* Custom Input/Output ranges are available. Refer to configuration guide.  
5B37 Specifications  
(typical @ +25°C and Vs = +5 V dc)  
Description  
Model 5B37  
Input Ranges  
Standard Ranges  
Refer to Model Table  
±5 mV to ±500 mV  
-5 V to +5 V or 0 to +5 V  
Accuracy2  
Custom Ranges  
Output Range (RL > 50 k)4  
Initial @ +25°C  
±0.05% Span ±10 µV RTI ±0.05% of Vz1 +CJC Sensor Error  
Nonlinearity  
±0.02% Span  
±1 µV/°C  
Input Offset vs. Temperature  
Output Offset vs. Temperature  
Gain vs. Temperature  
±20 µV/°C  
±0.0025% of Reading/°C  
Cold Junction Compensation  
±0.25°C (±0.75°C, maximum)  
±0.5°C (±0.0125°C/°C)  
-25 nA  
Initial Accuracy @ +25°C3  
Accuracy, +5°C to +45°C  
Input Bias Current  
Input Resistance  
5 MΩ  
Power On  
Power Off  
Overload  
40 kΩ  
40 kΩ  
Noise  
Input, 0.1 Hz to 10 Hz Bandwidth  
Output, 100 kHz Bandwidth  
0.2 µV rms  
200 µV rms  
Rev. 0 | Page 3 of 8  
5B37  
Bandwidth, -3 dB  
4 Hz  
Output Rise Time, 10% to 90% Span  
200 ms  
Common-Mode Voltage (CMV)4  
1500 V rms, maximum  
±3 V, maximum  
ANSI/IEEE C37.90.1-1989  
Common Mode Rejection (CMR)  
160 dB  
Input-to-Output, Continuous  
Output-to-Power, Continuous  
Transient  
1 kSource Imbalance, 50/60 Hz  
Normal Mode Rejection (NMR), 50/60 Hz  
60 dB  
Input Protection  
240 V rms, maximum  
ANSI/IEEE C37.90.1-1989  
50 Ω  
Continuous  
Transient  
Output Resistance  
Voltage Output Protection  
Output Selection Time  
Continuous Short to Ground  
6 µs @ Cload = 0 to 2,000 pF  
Output Enable Control  
+1 V  
Max Logic "0"  
Min Logic "1"  
+2.5 V  
Max Logic "1"  
+36 V  
Input Current "0"  
0.4 mA  
Open Input Response  
Open Input Response Time  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity, RTI  
Mechanical Dimensions  
Upscale  
10 seconds  
+5 V ±5%  
30 mA  
±2 µV/% of Vs  
2.275" x 2.375" x 0.595"  
(57.8 mm x 59.1 mm x 15.1 mm)  
Environmental  
Temperature Range  
Rated Performance  
Operating  
-25°C to +85°C  
-40°C to +85°C  
Storage  
-40°C to +85°C  
Relative Humidity  
RFI Susceptibility  
0 to 93% @ +40°C noncondensing  
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft  
1Vz is the nominal input voltage that results in a 0 V output.  
2Includes the combined effects of repeatability, hysteresis, and nonlinearity and assumes RL > 50 k. Loads heavier than 50 kwill degrade nonlinearity and gain temperature  
coefficient.  
3When used with the model AC1361 CJC sensor (see Accessories section), which is provided on each channel of 5B Series backplanes and mounting cards.  
4The output common must be kept within ±3 V of power common.  
Specifications subject to change without notice.  
Rev. 0 | Page 4 of 8  
5B37  
PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS  
Figure 3 5B37 input Field Connections  
Table 1. Pin Function Descriptions—  
Pin No.  
Description  
1
2
3
4
- EXC  
LO  
HI  
n/c  
Figure 4 . Model 5B Series Module, with pin-out assignments.  
ESD CAUTION  
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human  
body and test equipment and can discharge without detection. Although this product features proprietary ESD  
protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges.  
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.  
Rev. 0 | Page 5 of 8  
5B37  
OUTLINE DIMENSIONS  
Figure 5. Outline Dimensions  
Rev. 0 | Page 6 of 8  
5B37  
NOTES  
Rev. 0 | Page 7 of 8  
5B37  
NOTES  
©
2004 Analog Devices, Inc. All rights reserved. Trademarks and  
registered trademarks are the property of their respective companies.  
D05098-0-9/04(0)  
Rev. 0 | Page 8 of 8  

相关型号:

5B37-T-03

Isolated Thermocouple Input
ADI

5B37-T-03D1

Analog Circuit
ADI

5B37-T-03D3

Analog Circuit
ADI

5B37-T-15-FC

Analog Circuit
ADI

5B38

Isolated, Wide-Bandwidth Strain Gage Input
ADI

5B38-02

Isolated, Wide-Bandwidth Strain Gage Input
ADI

5B38-02-NI

Analog Circuit
ADI

5B38-04

Isolated, Wide-Bandwidth Strain Gage Input
ADI

5B38-04-NI

Analog Circuit
ADI

5B38-05

Isolated, Wide-Bandwidth Strain Gage Input
ADI

5B38-05-NI

Analog Circuit
ADI

5B39

Isolated Current Output
ADI