5B38-02-NI [ADI]

Analog Circuit;
5B38-02-NI
型号: 5B38-02-NI
厂家: ADI    ADI
描述:

Analog Circuit

文件: 总8页 (文件大小:701K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Isolated, Wide-Bandwidth Strain Gage Input  
5B38  
FUNCTIONAL BLOCK DIAGRAM  
FEATURES  
Wide-bandwidth Single-Channel Signal Conditioning  
Interfaces, Amplifies, and Filters signals from full-bridge and  
half-bridge strain-gage transduces between 300and 10kΩ.  
Isolated Precision Output of -5V to +5V.  
10 kHz bandwidth of the 5B38 ideally suits to measure  
signals that vary rapidly with time.  
Module circuitry can withstand 240v rms at the input screw-  
terminals.  
All 5B38 series modules are mix-and-match and Hot  
Swappable.  
Figure 1. 5B38 Functional Block Diagram  
There are also a number of backplanes and mounting sockets  
which provide a complete signal conditioning solution for end  
users. Each backplane incorporates screw terminals for field  
wiring inputs and outputs and cold junction sensors for  
thermocouple applications.  
APPLICATIONS  
Industrial signal conditioning  
Industrial signal isolation  
Industrial signal filtering  
These signal conditioners are designed to provide an easy and  
convenient solution to signal conditioning problems of both  
designers and end users in measurement and control  
applications. Typical uses include microcomputer-based  
measurement systems, standard data acquisition systems,  
programmable controllers, analog recorders and dedicated  
control systems. The 5 B series modules are ideally suited to  
applications where monitoring and control of temperature,  
pressure, flow, rotation and other analog signals are required.  
PRODUCT OVERVIEW  
The 5B Series represents an innovative generation of low cost,  
high performance plug-in signal conditioners. Designed for  
industrial applications, these modules incorporate highly  
reliable transformer-based isolation and automated surface-  
mount manufacturing technology. They are compact,  
economical components whose performance exceeds that  
available from more expensive devices. Combining 1500 V rms  
continuous isolation, +0.05% calibrated accuracy, small size and  
low cost, the 5B Series is an attractive alternative to expensive  
signal conditioners and in-house designs  
The 5B Series modules and backplanes are approved by Factory  
Mutual (FM) and the 5B Series modules are approved by the  
Canadian Standards Association (CSA) for use in Class 1,  
Division 2, Groups A, B, C, and D locations. These approvals  
certify that the 5B Series is suitable for use in locations where a  
hazardous concentration of flammable gas may exist only under  
fault conditions of operation. Equipment of this category is  
called “non-incendive” and they need no special enclosures or  
other physical safeguards.  
All modules are potted and identical in pin-out and size (2.27” x  
2.32” x 0.595”). They can be mixed and matched, permitting  
users to address their exact needs, and may be “hot swapped  
without disturbing field wiring or power. The isolated input  
modules provide 0 to +5V or +5V outputs and accept J, K, T, E,  
R, S, N, or B type thermocouples.  
These modules feature complete signal conditioning functions  
including 240 V rms input protection, filtering, chopper  
stabilized low drift +1 uV/oC amplification, 1500 V rms  
isolation, and sensor excitation when required.  
The 5B series modules and backplanes have been tested and  
passed the stringent heavy industrial requirements of the  
European Union’s electromagnetic compatibility (ENC)  
directive – EN50082-1 and EN50081-2. When used according  
to installation directions (refer to 5B series User Manual), any  
errors caused by EMI/RFI interference will be less than 0.1% of  
the full scale 5B measurement range for field strengths up to 10  
V/M and frequencies up to 1 GHz.  
All modules feature excellent common mode rejection and  
meet industrial transient surge withstand specifications.  
Rev. 0  
Information furnished by Analog Devices is believed to be accurate and reliable.  
However, no responsibility is assumed by Analog Devices for its use, nor for any  
infringements of patents or other rights of third parties that may result from its use.  
Specifications subject to change without notice. No license is granted by implication  
or otherwise under any patent or patent rights of Analog Devices. Trademarks and  
registered trademarks are the property of their respective companies.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700  
Fax: 781.326.8703  
www.analog.com  
© 2004 Analog Devices, Inc. All rights reserved.  
5B38  
GENERAL DESCRIPTION  
bandwidth and yields optimal noise performance for accurate  
The 5B38 is a wide-bandwidth single-channel signal  
measurement of small signals in high electrical noise. A  
chopper-stabilized input amplifier provides low drift and stable  
gain.  
conditioning module that interfaces, amplifies, and filters  
signals from full-bridge and half-bridge strain-gage transducers  
between 300and 10k. The module provides an isolated  
bridge excitation of +10V and a protected, isolated precision  
output of -5V to +5V. The 10 kHz bandwidth of the module  
ideally suits to measure signals that vary rapidly with time, such  
as strain on an automobile chassis during a crash test.  
Signal isolation by transformer coupling uses a proprietary  
modulation technique for linear, stable and reliable  
performance. The differential input circuit on the field side is  
fully floating, eliminating the need for any input grounding. A  
demodulator on the computer side of the signal transformer  
recovers the original signal, which is then filtered and buffered  
to provide a low-noise, low-impedance output signal. An  
additional benefit, the output section acts as a third floating  
port, eliminating possible problems from ground loops and  
power-supply noise. The output common must be kept within  
+3V of power common.  
The 5B38 protects the computer side from damage due to field-  
side over-voltage faults. The module withstands 240V rms at its  
input terminals without damage, thereby shielding computer-  
side circuitry from field-side over-voltage conditions. In  
addition, the 5B38 is mix-and-match and hot-swappable with  
all 5B Series modules, so can be inserted or removed from any  
socket in the same backplane without disrupting system power.  
A series output switch eliminates the need for external  
multiplexing in many applications. The switch is turned on by  
an active-low enable input. If the switch is to be on at all times,  
the enable-input should be grounded to power common as it is  
on the 5B01 and 5B08 backplanes..  
The 5B38-04 contains bridge completion circuitry, so can  
function with half-bridge strain gages. For quarter-bridge  
requirements, the user must complete the bridge input to the  
half-bridge level externally. The factory can configure the  
module for a wide range of input ranges (sensitivities).  
A signle-pole anti-aliasing filter resides at each modules input.  
A three-pole, low-pass filter in the output stage sets the  
.
.
Figure 2  
Rev. 0 | Page 2 of 8  
5B38  
5B38 Models Available  
Model  
Input Bridge Type  
Bridge Range  
300 to 10 kΩ  
300 to 10 kΩ  
300 to 10 kΩ  
300 to 10 kΩ  
Excitation  
+10.0 V  
+10.0 V  
+10.0 V  
+10.0 V  
Sensitivity  
3 mV/V  
3 mV/V  
2 mV/V  
*
Output Range  
5B38-02  
Full Bridge  
Half Bridge  
Full Bridge  
*
-5 V to +5 V  
-5 V to +5 V  
-5 V to +5 V  
-5 V to +5 V  
5B38-04  
5B38-05  
5B38-Custom  
* Custom Input/sensitivity ranges are available. Refer to configuration guide.  
5B38 Specifications  
Description  
Model 5B38 Full Bridge  
Model 5B38 Half Bridge  
Input Ranges  
Standard Ranges  
Custom Ranges  
±20 mV (2 mV/V Sensitivity)  
±30 mV (3 mV/V Sensitivity)  
±30 mV (3 mV/V Sensitivity)  
±10 mV to ±500 mV  
-5 V to +5 V  
*
*
Output Ranges (RL > 50 k)  
Accuracy2  
Initial @ +25°C  
±0.08% Span ±10 µV RTI  
±0.02% Span  
±1 µV/°C  
±0.08% Span ±1 mV RTI  
Nonlinearity  
*
Input Offset vs. Temperature  
Output Offset vs. Temperature  
Gain vs. Temperature  
Excitation Voltage Output @ full load  
Load Range  
*
±40 µV/°C  
*
±25 ppm of Reading/°C  
+10 V ±3 mV  
10 k, minimum; 300 , maximum  
±5 ppm/mA  
*
*
*
Load Regulation  
*
vs. Temperature  
±15 ppm/°C  
*
Half Bridge Voltage Level  
Half Bridge Voltage vs. Temperature  
Input Bias Current  
N/A  
+5 V ±1 mV  
±15 ppm/°C  
*
N/A  
±3 nA  
Input Resistance  
20 M, minimum  
40 k, minimum  
40 k, minimum  
Noise  
Power On  
Power Off  
Overload  
*
*
*
Input, 0.1 Hz to 10 Hz Bandwidth  
Input, 10 kHz Bandwidth  
0.4 µV rms  
2 µV rms  
±70 nV/ Hz  
±250 nV/  
*
Hz  
Output, 100 kHz Bandwidth  
10 mV peak-peak  
Rev. 0 | Page 3 of 8  
5B38  
Bandwidth, -3 dB  
10 kHz  
40 µs  
*
Output Rise Time, 10% to 90% Span  
Output Settling Time, to 0.1%  
*
250 µs  
7 ms  
Common-Mode Voltage (CMV)  
Input-to-Output, Continuous  
Output-to-Power, Continuous2  
Transient  
1500 V rms, maximum  
±3 V, maximum  
*
*
*
ANSI/IEEE C37.90.1-1989  
Common-Mode Rejection (CMR)  
100 dB  
*
*
1 kSource Imbalance, 50/60 Hz  
Normal Mode Rejection, 50/60 Hz  
-3 dB @ 10 kHz  
Input Protection, Signal and Excitation Voltage  
240 V rms maximum  
ANSI/IEEE C37.90.1-1989  
50 Ω  
Continuous  
*
*
*
*
*
Transient  
Output Resistance  
Voltage Output Protection  
Output Selection Time  
Continuous Short to Ground  
6 µs @ Cload = 0 to 2,000 pF  
Output Enable Control  
+1 V  
Max Logic "0"  
*
*
*
*
*
*
*
*
Min Logic "1"  
+2.5 V  
Max Logic "1"  
+36 V  
Input Current "0"  
0.4 mA  
Power Supply Voltage  
Power Supply Current  
Power Supply Sensitivity  
Mechanical Dimensions  
+5 V ±5%  
200 mA, Full Load; 120 mA, No Load  
25 ppm reading/% ±2.5µV RTI/%  
2.275" x 2.375" x 0.595"  
(57.8 mm x 59.1 mm x 15.1 mm)  
Environmental  
Temperature Range  
Rated Performance  
Operating  
-25°C to +85°C  
*
*
*
*
*
-40°C to +85°C  
Storage  
-40°C to +85°C  
Relative Humidity  
RFI Susceptibility  
* Same as full-bridge version.  
0 to 93% @ +40°C non-condensing  
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft  
1 Includes the combined effects of repeatability, hysteresis, and nonlinearity. Loads heavier than  
50 kwill degrade nonlinearity and gain temperature coefficient.  
2 The output common must be kept within ±3 V of power common.  
Specifications subject to change without notice.  
Rev. 0 | Page 4 of 8  
5B38  
PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS  
x
Figure 3 5B38 Input Field Connections  
Table 1. Pin Function Descriptions—  
Pin No.  
Description  
1
2
3
4
-EXC  
LO  
HI  
+EXC  
Figure 4 . Model 5B Series Module, with pin-out assignments.  
ESD CAUTION  
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human  
body and test equipment and can discharge without detection. Although this product features proprietary ESD  
protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges.  
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.  
Rev. 0 | Page 5 of 8  
5B38  
OUTLINE DIMENSIONS  
Figure 5. Outline Dimensions  
Rev. 0 | Page 6 of 8  
5B38  
NOTES  
Rev. 0 | Page 7 of 8  
5B38  
NOTES  
©
2004 Analog Devices, Inc. All rights reserved. Trademarks and  
registered trademarks are the property of their respective companies.  
D05099-0-9/04(0)  
Rev. 0 | Page 8 of 8  

相关型号:

5B38-04

Isolated, Wide-Bandwidth Strain Gage Input
ADI

5B38-04-NI

Analog Circuit
ADI

5B38-05

Isolated, Wide-Bandwidth Strain Gage Input
ADI

5B38-05-NI

Analog Circuit
ADI

5B39

Isolated Current Output
ADI

5B39-01

Isolated Current Output
ADI

5B39-02

Isolated Current Output
ADI

5B39-03

Isolated Current Output
ADI

5B39-04

Isolated Current Output
ADI

5B40

Isolated, Wide Bandwidth Millivolt and Voltage Input
ADI

5B40-01

Isolated, Wide Bandwidth Millivolt and Voltage Input
ADI

5B40-01-NI

Analog Circuit
ADI