VCE03US03 [XPPOWER]

AC-DC Power Supplies 3 Watts;
VCE03US03
型号: VCE03US03
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Power Supplies 3 Watts

文件: 总4页 (文件大小:602K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC-DC Power Supplies  
VCE03 Series  
3 Watts  
• Ultra Compact SIL Package  
• Single Outputs from 3.3 to 48VDC  
• PCB Mount  
• Encapsulated & Open Frame  
• 85 to 305VAC Input  
• ITE & Household Appliance Approvals  
• Class II  
• <0.3 W No Load Input Power  
• Low Cost  
GREEN  
POWER  
Dimensions:  
• 3 Year Warranty  
VCE03:  
1.60 x 0.75 x 0.75” (40.6 x 19.10 x 19.10 mm)  
VCE03-P:  
The VCE03 is a series of open frame and encapsulated AC-DC single output power supplies  
designed for low cost ITE industrial and domestic applications. The series provides two mechanical  
options including open frame and encapsulated PCB mount. With approvals to world-wide safety  
standards including ITE and household, compliance with class B for conducted and radiated  
emissions, these class II isolation parts benefit system designers with easy integration into a wide  
range of applications.  
1.50 x 0.65 x 0.65” (38.1 x 16.5 x 16.5 mm)  
Models & Ratings  
Output Power  
Output Voltage  
Output Current  
Model Number (1)  
3 W  
3 W  
3 W  
3 W  
3 W  
3 W  
3 W  
3.3 VDC  
5.0 VDC  
9.0 VDC  
12.0 VDC  
15.0 VDC  
24.0 VDC  
48.0 VDC  
910 mA  
600 mA  
333 mA  
250 mA  
200 mA  
125 mA  
63 mA  
VCE03US03  
VCE03US05  
VCE03US09  
VCE03US12  
VCE03US15  
VCE03US24  
VCE03US48  
Notes  
1. For Open Frame version add suffix -P to model number, e.g. VCE03US12-P.  
Summary  
Characteristic  
Input Voltage Range  
No Load Input Power  
Efficiency  
Minimum  
Typical  
Maximum  
305  
Units  
VAC  
W
Notes & Conditions  
85  
Derate from 100% at 90 VAC to 90% at 85 VAC  
0.3  
80  
%
Model dependant  
Operating Temperature  
EMC  
-25  
+70  
°C  
Derate linearly from 100% at +50 °C to 50% at +70 °C  
EN55032 Level B Conducted & Radiated, EN601000-3-2, EN61000-3-3, EN55024  
IEC62368-1, IEC60335-1, IEC60950-1, EN62368-1, EN60335-1, UL62368-1  
Safety Approvals  
Input  
Characteristic  
Minimum  
Typical  
Maximum  
305  
Units  
Notes & Conditions  
Covers all standard voltages in range from 100 VAC to  
277 VAC  
Input Voltage Range  
85  
47  
VAC  
Input Frequency  
63  
Hz  
A rms  
W
Input Current - Full Load  
No Load Input Power  
Inrush Current  
Earth Leakage Current  
Input Protection  
0.10/0.06/0.04  
At 115/230/277 VAC  
0.3  
40/44.2  
A
At 230/277 VAC, cold start 25 °C  
Class II construction no earth  
External T1.0 A/300 VAC fuse required in line  
www.xppower.com  
1
AC-DC Power Supplies  
VCE03 Series  
Output  
Characteristic  
Output Voltage  
Initial Set Accuracy  
Minimum Load  
Minimum  
Typical  
Maximum  
Units  
VDC  
%
Notes & Conditions  
3.3  
48  
2/1  
At 50% load for 3.3 & 5 V m  
No minimum lo  
ad required  
odels/Other models  
0
A
For 3.3 & 5 V models/Other  
Includes inital set accuracy  
regulation is 7% max from  
models: from 10% to 100%  
, line and load regulation. T  
otal  
0% to 100% load.  
load.  
Total Regulation  
5/3  
%
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
2
30  
s
ms  
ms  
16  
20  
at full load and  
115 VAC  
Deviation, recovery within 1  
for a 25% load change  
% in less than 500 µs  
Transient Response  
Ripple & Noise  
4
%
180/120  
1
140  
mV pk-pk  
% pk-pk  
% Vnom  
%
3.3 & 5 V/9 V models, 20 M  
12 V to 48 V models, 20 MH  
210% typical for 3.3 V mod  
Hz bandwidth  
z bandwidth  
Overvoltage Protection  
Overload Protection  
115  
110  
els, auto recovery  
180  
Short Circuit Protection  
Temperature Coefficient  
Trip & Restart (hiccup mod  
e)  
0.02  
%/˚C  
General  
Characteristic  
Efficiency  
Minimum  
Typical  
80  
Maximum  
Units  
%
Notes & Conditions  
At 115 VAC, Model Dependant  
Isolation: Input to Output  
Switching Frequency  
Power Density  
3000  
5
VAC  
kHz  
W/in  
52  
4.7  
Varies with load  
For ‘-P’ version  
3
Mean Time Between Failure  
400  
kHrs  
lb (g)  
lb (g)  
MIL-HDBK-217F, +25 °C GB  
Open frame versions (-P)  
Encapsulated version  
0.025 (11)  
0.067 (30)  
Weight  
Efficiency Graphs  
VCE03US12-P  
100%  
80%  
60%  
40%  
20%  
115Vac input  
230Vac input  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
100%  
80%  
60%  
40%  
20%  
VCE03US24-P  
115Vac input  
230Vac input  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
www.xppower.com  
2
AC-DC Power Supplies  
VCE03 Series  
Environmental  
Characteristic  
Operating Temperature  
Storage Temperature  
Cooling  
Minimum  
Typical  
Maximum  
+70  
Units  
°C  
Notes & Conditions  
-25  
-40  
Derate linearly from 100% at +50 °C to 50% at +70 °C  
+85  
°C  
Convection-cooled  
Non-condensing  
Humidity  
95  
%RH  
m
Operating Altitude  
Shock  
3048  
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes  
IEC68-2-6, 2 g, 10 Hz to 500 kHz, 10 mins/cycle, 60 mins each cycle  
Vibration  
EMC: Emissions  
Phenomenon  
Standard  
EN55032  
Test Level  
Criteria  
Notes & Conditions  
If output is connected to a ground additional  
external components will be required. Contact sales  
for details  
Conducted  
Class B  
Radiated  
EN55032  
Class B  
Harmonic Current  
Voltage Flicker  
EN61000-3-2  
EN61000-3-3  
Class A  
EMC: Immunity  
Phenomenon  
ESD  
Standard  
Test Level  
Criteria  
Notes & Conditions  
6kV contact,  
8kV air discharge  
EN61000-4-2  
A
Radiated  
EFT  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
10 V/m  
3
A
A
A
A
A
A
B
A
B
A
A
A
B
Surge  
2
Line to Line  
Conducted  
Magnetic Fields  
10 Vrms  
30 A/m  
T
70% U (80.5 VAC) for 100 ms  
T
40% U (46 VAC) for 200 ms  
EN61000-4-11 (115 VAC)  
EN61000-4-11 (230 VAC)  
A at High Line, B at Low Line  
A at High Line, B at Low Line  
T
<5% U (0 VAC) for 10 ms  
T
<5% U (0 VAC) for 5000 ms  
Dips and Interruptions  
T
70% U (161 VAC) for 100 ms  
T
40% U (92 VAC) for 200 ms  
T
<5% U (0 VAC) for 10 ms  
T
<5% U (0 VAC) for 5000 ms  
Safety Approvals  
Safety Agency  
Safety Standard  
IEC60950-1  
IEC62368-1  
IEC60335-1  
IEC61558-1  
UL62368-1  
Notes & Conditions  
ITE  
CB  
Household, Encapsulated Version  
Power Supply Units  
UL  
ITE  
TUV  
EN62368-1  
www.xppower.com  
3
AC-DC Power Supplies  
VCE03 Series  
Mechanical Details  
Encapsulated  
1.6 (40.6)  
1.6 (40.6)  
1.10 (27.94)  
0.20  
(5.08)  
0.1 (2.54)  
0.1 (2.54)  
1.10 (27.94)  
0.20  
(5.08)  
0.1 (2.54)  
0.1 (2.54)  
0.75  
(19.1)  
PCB LAYOUT PATTERN  
TOP VIEW  
TOP VIEW  
0.75  
(19.1)  
0.415  
(10.53)  
0.41  
(10.5)  
1.1 mm plated through hole  
1.6 mm pad size  
0.75  
(19.1)  
Pin Connections  
Single  
Pin  
1
0.19  
(4.8)  
ACL  
ACN  
2
1
2
3
4
3
+Vout  
-Vout  
4
0.025 (0.64)  
Open Frame (-P)  
1.5 (38.1)  
1.1 mm plated through hole  
1.6 mm pad size  
0.55  
(14.0)  
0.19  
(4.8)  
max  
0.10  
(2.5)  
max  
0.65  
(16.5)  
PCB LAYOUT PATTERN  
TOP VIEW  
0.65  
(16.5)  
max  
0.36  
(9.2)  
1.5 (38.1)  
0.05 (1.3)  
1.1 (27.94)  
0.20 (5.08)  
0.10 (2.54)  
0.65  
(16.5)  
0.24  
(6.0)  
1
2
3
4
0.05 (1.3)  
1.1 (27.94)  
0.20 (5.08)  
0.10 (2.54)  
Notes  
1. Dimensions in inches (mm).  
2. Weight: Open frame versions (-P): 0.025 lbs (10 g)  
Encapsulated: 0.067 lbs (30 g)  
3. Tolerances:  
x.xx = 0.02 (x.x = 0.5)  
x.xxx = 0.01 (x.xx = 0.25)  
www.xppower.com  
11 May 18  

相关型号:

VCE03US05

AC-DC Power Supplies 3 Watts
XPPOWER

VCE03US09

AC-DC Power Supplies 3 Watts
XPPOWER

VCE03US12

AC-DC Power Supplies 3 Watts
XPPOWER

VCE03US15

AC-DC Power Supplies 3 Watts
XPPOWER

VCE03US24

AC-DC Power Supplies 3 Watts
XPPOWER

VCE03US48

AC-DC Power Supplies 3 Watts
XPPOWER

VCE03_18

AC-DC Power Supplies 3 Watts
XPPOWER

VCE05

AC-DC Power Supplies 5 Watts
XPPOWER

VCE05US03

暂无描述
XPPOWER

VCE05US03-P

AC-DC, 5W, P 1X1", PCB MOUNT, OP
XPPOWER

VCE05US05

AC-DC, 5W, P 1X1", PCB MOUNT, EN
XPPOWER

VCE05US05-P

AC-DC, 5W, P 1X1", PCB MOUNT, OP
XPPOWER