EME05US12 [XPPOWER]
AC-DC Power Supplies;型号: | EME05US12 |
厂家: | XP POWER LIMITED |
描述: | AC-DC Power Supplies |
文件: | 总4页 (文件大小:665K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies
EME05 Series
5 Watts
• Compact Size
• Medical Approvals
• Single Outputs from 3.3 to 48 V
• PCB Mount
• Encapsulated & Open Frame
• Class II
• Peak Load Capability
• 3 Year Warranty
GREEN
POWER
Dimensions:
The EME05 is a series of open frame and encapsulated AC-DC single output power supplies
designed for medical applications. The series provides two mechanical options including open
frame and encapsulated PCB mount. With approvals to world-wide medical safety standards,
compliance with class B for both conducted and radiated emissions and a 130%, 30s peak load
capability, these class II isolation parts benefit system designers with easy integration into the latest
healthcare products and applications.
EME05:
1.50 x 1.00 x 0.60” (36.1 x 25.4 x 15.2 mm)
EME05-P:
1.40 x 0.94 x 0.69” (35.6 x 23.7 x 17.6 mm)
Models & Ratings
Output Current
Output Power
Output Voltage
Model Number(2)
Nominal
1510 mA
1000 mA
555 mA
416 mA
333 mA
208 mA
138 mA
104 mA
Peak(1)
5 W
5 W
5 W
5 W
5 W
5 W
5 W
5 W
3.3 VDC
5.0 VDC
1960 mA
1300 mA
722 mA
541 mA
433 mA
270 mA
180 mA
135 mA
EME05US03
EME05US05
EME05US09
EME05US12
EME05US15
EME05US24
EME05US36
EME05US48
9.0 VDC
12.0 VDC
15.0 VDC
24.0 VDC
36.0 VDC
48.0 VDC
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal.
2. For Open Frame version add suffix -P to model number, e.g. EME05US12-P.
Summary
Characteristic
Input Voltage Range
No Load Input Power
Efficiency
Minimum
Typical
Maximum
264
Units
VAC
W
Notes & Conditions
85
Derate from 100% at 90 VAC to 90% at 85 VAC
0.3
72
86
%
Operating Temperature
EMC
-25
+70
°C
Derate linearly from 100% at +50 °C to 50% at +70 °C
EN55011 Level B Conducted & Radiated, EN601000-3-2, EN61000-3-3, EN60601-1-2
EN60601-1, ANSI/AAMI ES60601-1. IEC60601-1
Safety Approvals
www.xppower.com
1
AC-DC Power Supplies
EME05 Series
Input
Characteristic
Input Voltage Range
Input Frequency
Minimum
Typical
Maximum
264
Units
VAC
Hz
Notes & Conditions
85
47
63
Input Current - Full Load
No Load Input Power
Inrush Current
0.10/0.06
A rms
W
A
At 115/230 VAC
0.3
40
At 230 VAC
Earth Leakage Current
Input Protection
Class II construction no earth
Internal T1.0 A/250 VAC fuse fitted in line and neutral
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Minimum
Typical
Maximum
Units
VDC
%
A
s
ms
ms
%
Notes & Conditions
3.3
48
1
0
No minimum load required
at full load and 115 VAC
2
14
12
Line Regulation
Load Regulation
0.5
1
%
Deviation, recovery within 1% in less than 500 µs
for a 25% load change
Transient Response
4
%
50
90
120
200
140
200
mV pk-pk
mV pk-pk
mV pk-pk
mV pk-pk
% Vnom
%
3.3-5 V versions, 20 MHz bandwidth
9 V versions, 20 MHz bandwidth
12-15 V versions, 20 MHz bandwidth
24-48 V versions, 20 MHz bandwidth
Recycle input to reset
Ripple & Noise
Overvoltage Protection
Overload Protection
115
130
Short Circuit Protection
Temperature Coefficient
Trip & Restart (hiccup mode)
0.05
%/˚C
General
Characteristic
Efficiency
Minimum
Typical
80
Maximum
Units
%
Notes & Conditions
Isolation: Input to Output
Switching Frequency
Power Density
4000
VAC
kHz
W/in
2 MOPP
130
3
5.5
Mean Time Between Failure
>400
0.03 (14)
0.053 (24)
kHrs
lb (g)
lb (g
MIL-HDBK-217F, +25 °C GB
Open frame versions (-P)
Encapsulated version
Weight
Efficiency Graphs
EME05US12
EME05US24
100%
90%
80%
70%
60%
50%
40%
100%
90%
80%
70%
60%
50%
40%
115Vac input
230Vac input
10
20
30
40
50
60
70
80
90
100
10
20
30
40
50
60
70
80
90
100
Load (%)
Load (%)
www.xppower.com
2
AC-DC Power Supplies
EME05 Series
Environmental
Characteristic
Operating Temperature
Storage Temperature
Cooling
Minimum
-25
Typical
Maximum
+70
Units
°C
Notes & Conditions
Derate linearly from 100% at +50 °C to 50% at +70 °C
-40
+85
°C
Convection-cooled
Non-condensing
Humidity
95
%RH
m
Operating Altitude
Shock
3048
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
IEC68-2-6, 2 g, 10 Hz to 500 kHz, 10 mins/cycle, 60 mins each cycle
Vibration
EMC: Emissions
Phenomenon
Conducted
Standard
EN55011
Test Level
Class B
Criteria
Notes & Conditions
Radiated
EN55011
Class B
Harmonic Current
Voltage Flicker
EN61000-3-2
EN61000-3-3
Class A
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
Notes & Conditions
Medical Device EMC
IEC60601-1-2
Ed 4.0: 2014
As below
8kV contact,
15kV air discharge
ESD
EN61000-4-2
A
80% mod, 80 MHz - 2.7 GHz plus discrete
communcation proximity field frequencies
Radiated
EN61000-4-3
10 V/m
A
EFT
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
3
A
A
A
A
A
A
A
B
A
A
A
B
Surge
2
Conducted
Magnetic Fields
10 Vrms
30 A/m
T
70% U (70 VAC) for 500 ms
Load de-rated to 50%
T
40% U (40 VAC) for 100 ms
EN60601-1-2 (100 VAC)
EN60601-1-2 (240 VAC)
T
<5% U (0 VAC) for 10 ms
T
<5% U (0 VAC) for 5000 ms
Dips and Interruptions
T
70% U (168 VAC) for 500 ms
T
40% U (96 VAC) for 100 ms
T
<5% U (0 VAC) for 10 ms
T
<5% U (0 VAC) for 5000 ms
Safety Approvals
Safety Agency
CB Report
UL
Safety Standard
Notes & Conditions
Medical
IEC60601-1 Including Risk Management
ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08
EN60601-1
Medical
TUV
Medical
Means of Protection
Category
Primary to Secondary
2 x MOPP (Means of Patient Protection)
IEC60601-1 Ed 3.1
www.xppower.com
3
AC-DC Power Supplies
EME05 Series
Mechanical Details
Encapsulated
BOTTOM VIEW
1.0 (25.4)
0.20
(5.1)
0.75 (19.05)
0.60 (15.2)
0.10 (2.53)
2
3
1
1.50
4 Ø0.04
(Ø1.02)
(38.1)
1.30
(33.02)
0.10
(2.54)
4
0.10 (2.53)
0.5 (12.7)
Pin Connections
Pin
1
Single
ACN
Open Frame (-P)
0.50
(12.7)
1.40 (35.6)
2
ACL
3
-Vout
+Vout
4
2
1
3
4
0.94
(23.7)
0.37
0.05 (1.28)
1.30 (33.02)
(9.40)
0.51
(13.0) max
0.17
(4.4)
0.15
(3.8)
0.69
(17.6)
Ø0.039 (Ø1.00)
Ø0.071 (Ø1.80)
Notes
1. Dimensions in inches (mm).
2. Weight: Open frame versions (-P): 0.03 lbs (14 g)
Encapsulated: 0.053 lbs (24 g))
3. Tolerances:
x.xx = 0.02 (x.x = 0.5)
x.xxx = 0.01 (x.xx = 0.25)
www.xppower.com
10 Dec 15