ECS45US05 [XPPOWER]
2560 Watts ECS Series; 25 ? 60瓦ECS系列型号: | ECS45US05 |
厂家: | XP POWER LIMITED |
描述: | 2560 Watts ECS Series |
文件: | 总4页 (文件大小:405K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
25ꢀ60 Watts
ECS Series
xppower.com
•
•
•
•
•
•
•
IT & Medical Safety Approvals
Very Small 2” x 3” x 0.95” Package
<0.3 W No Load Input Power
25, 45 & 60 W ꢀ Convection Cooled Ratings
Class I & Class II Installations
ꢀ20 °C to +70 °C Operation
3 Year Warranty
Specification
Input
General
Efficiency
Isolation
• Up to 90%, model dependant
Input Voltage
• 80-264 VAC (120-370 VDC), derate linearly
from 100% at 90 VAC to 80% at 80 VAC
• 4000 VAC In to Out, 2 x MOPP, 1500 VAC In
to Earth, 1 x MOPP, 500 VDC Out to Earth, 1
x MOPP
(1)
Input Frequency
Input Current
• 47-400 Hz
• 25 W: 0.45 A, 45 W: 0.75 A, 60 W: 0.95 A
typical at 115 VAC, full load,
25 W: 0.30 A, 45 W: 0.45 A, 60 W: 0.60 A,
typical at 230 VAC, full load
• 40 A max at 230 VAC, cold start 25 ˚C
• EN61000-3-2, class A
Switching Frequency
Power Density
MTBF
• 65 KHz typical
• Up to 7.9 W/in
3
• 25 & 45 W: 1072 kHrs, 60 W: 471 kHrs to
MIL-HDBK-217F at 25 ˚C, GB
Inrush Current
Power Factor
Environmental
Operating Temperature • -20 ˚C to +70 ˚C derate linearly from +50 ˚C
No Load Input Power • US05, 12 & 24 models: <0.3 W,
US48 and all ECS60 models: <0.5 W
at 2.5%/˚C to 50% load at +70 ˚C.
• Convection, see thermal considerations
• 95% RH, non-condensing
Earth Leakage Current • 260 µA at 264 VAC/60 Hz max,
Cooling
80/160 µA typical 115/230 VAC
• T3.15 A/250 V internal fuse in line
and neutral
Operating Humidity
Input Protection
Storage Temperature • -40 ˚C to +85 ˚C
Operating Altitude
Shock
• 3000 m
• 30 g pk, half sine, 6 axes
• 2 g rms, 5 Hz to 500 kHz, 3 axes
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
• 5-48 VDC (see tables)
Vibration
•
•
10%
1%
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level
• No minimum load required
• 1 s typical
• 50 ms
Emissions
• All models: EN55011/22 level B conducted.
45 & 60 W: EN55011/22 level A radiated,
ECS25 & some ECS60 models: level B
radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3
Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation.
• 16 ms min at 115 VAC
(3)
Drift
•
•
•
0.2% after 20 min warm up
0.5% max
1%
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
• 5% typical
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Surge
Conducted Immunity
Dips & Interruptions
(2)
Ripple & Noise
• 1% pk-pk V1, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overload Protection • 110-160%
Short Circuit Protection • Continuous trip and restart (hiccup mode)
Temperature
Coefficient
• 0.05%/˚C
Safety Approvals
• IEC60950-1 CB report, UL60950-1,
TUV EN60950-1, IEC60601-1 CB report,
ANSI/AAMI ES60601-1, TUV 60601-1,
Including Risk Management
Notes
1. Safety approvals cover frequency 47-63 Hz.
2. ECS60US12 1.5% pk-pk, 20 MHz bandwidth under certain line/load conditions.
3. See longform datasheet or contact sales for details.
Equipment Protection • Class I and Class II
Class
ECS25
Models and Ratings
Output Power
25 W
Output Voltage
12.0 VDC
Output Current
2.08 A
Model Number(1)
ECS25US12
ECS25US15
ECS25US24
ECS25US48
25 W
15.0 VDC
1.67 A
25 W
24.0 VDC
1.04 A
25 W
48.0 VDC
0.52 A
Notes
1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations,
derate output power by 20% with cover.
Mechanical Details
4 x Ø.156 (3.96) Mounting Holes
2.75 (69.8)
Ø.312 (7.92) Clearance Top and Bottom
Input Connector J1
Molex PN 09-65-2038
Pin 1
Pin 2
0.25” Faston
Line
Neutral
Earth
2
1
1
2
J1
J2
3
4
C18
C5
1.75
2.00
Output Connector J2
Molex PN 09-65-2048
(44.4)
(50.8)
1.65
(41.8)
1.31
(33.3)
Pin 1
+V1
+V1
RTN
RTN
T1
Pin 2
Pin 3
Pin 4
Q1
0.27
(7.0)
0.20
0.25 (0.6) Faston Ground Tab
(5.1)
J1 mates with Molex Housing PN 09-50-1031,
J2 mates with Molex Housing PN 09-50-1041 and
both with Molex Series 5194 Crimp Terminals
3.00 (76.2)
Notes
0.14 (3.6)
0.95 (24.2)
1. All dimensions in inches (mm).
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Weight 0.22 lbs (100 g)
SMD Height
Covered version (All ECS25ꢀ60 Models)
2 x M3 x 0.5 THD
0.16 (4.0) Max
2 x M3 x 0.5 THD
0.16 (4.0) Max
Screw Penetration
Screw Penetration
1.26
0.63
(32.0)
(16.0)
Output Connector
0.22 (5.7)
J2
1
4
3.03
3.48
(76.99)
3.03
(88.4)
(76.9)
1
2
J1
0.22 (5.7)
Input
0.25 (0.6) Faston Ground Tab
0.70
Top View
Connector
2.52
(17.79)
(64.0)
Bottom View
1.40
(35.6)
Notes
1. All dimensions in inches (mm).
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Weight 0.5 lbs (230 g)
ECS45
Models and Ratings
Output Power
30 W
Output Voltage
5.0 VDC
Output Current
6.00 A
Model Number(1)
ECS45US05
ECS45US12
ECS45US15
ECS45US24
ECS45US48
45 W
12.0 VDC
15.0 VDC
24.0 VDC
48.0 VDC
3.75 A
45 W
3.00 A
45 W
1.90 A
45 W
0.95 A
Notes
1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations,
derate output power by 20% with cover.
Mechanical Details
4 x Ø.156 (3.96) Mounting Holes
Ø.312 (7.92) Clearance Top and Bottom
2.75 (69.9)
5 V version
2
1
1
2
J1
C18
J2
2.00
C5
3
4
(50.8)
Input Connector J1
Molex PN 09-65-2038
1.75
(44.5)
1.58
Pin 1
Line
Neutral
Earth
(40.3)
1.30
(33.0)
Pin 2
T1
0.25” Faston
Output Connector J2
Molex PN 09-65-2048
Q1
0.28
(7.0)
0.20
(5.1)
Pin 1
+V1
+V1
RTN
RTN
0.25 (0.6) Faston Ground Tab
Pin 2
Pin 3
Pin 4
3.00 (76.2)
J1 mates with Molex Housing PN
09-50-1031,
J2 mates with Molex Housing
PN 09-50-1041 and both with Molex
Series 5194 Crimp Terminals
1.05
(26.7)
0.14 (3.6) SMD Height Limit
4 x Ø.156 (3.96) Mounting Holes
Ø.312 (7.92) Clearance Top and Bottom
12ꢀ48 V version
2.75 (69.9)
2
1
1
2
J1
J2
3
4
C18
Input Connector J1
C5
2.00
Molex PN 09-65-2038
(50.8 )
1.75
1.65
Pin 1
Pin 2
0.25” Faston
Line
Neutral
Earth
(44.5)
(41.8)
1.31
(33.3)
T1
Output Connector J2
Molex PN 09-65-2048
Q1
Pin 1
+V1
+V1
RTN
RTN
0.28
(7.0)
0.20
(5.1)
0.25 (0.6) Faston Ground Tab
3.00 (76.2)
Pin 2
Pin 3
Pin 4
J1 mates with Molex Housing PN
09-50-1031,
J2 mates with Molex Housing PN 09-
50-1041 and both with Molex Series
5194 Crimp Terminals
0.95
(24.2)
0.14 (3.6)
SMD Height
Notes
1. All dimensions in inches (mm).
2. Weight 0.22 lbs (100 g)
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
ECS60
Models and Ratings
Output Power
40 W
Output Voltage
5.0 VDC
Output Current
8.00 A
Model Number(1)
ECS60US05
ECS60US12
ECS60US15
ECS60US24
ECS60US48
60 W
12.0 VDC
15.0 VDC
24.0 VDC
48.0 VDC
5.00 A
60 W
4.00 A
60 W
2.50 A
60 W
1.25 A
Notes
1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations,
derate output power by 20% with cover.
Mechanical Details
0.28 (7.1)
4 x ø0.156 (3.96) mounting holes
ø3.12 (7.92) clearance top and bottom
1.05 (26.7)
0.20 (5.1)
A
1
4
J2
C18
2.00
(50.8)
1.75
C5
(44.4)
1.62
(41.1)
1.30
(33.0)
T1
A
Q1
0.14 (3.5)
0.12
(3.18)
Components may
extend beyond
edge of PCB
0.25 faston ground tab
0.12
(3.1)
2.75 (69.8)
by 0.04 (1.0)
3.00 (76.2)
Mounting points A should be connected together for optimum EMI performance
Output Connector J2
Molex PN 09-65-2048
Input Connector J1
Molex PN 09-65-2038
Pin 1
+V1
+V1
RTN
RTN
Pin 1
Pin 2
Line
Neutral
Earth
Pin 2
Pin 3
Pin 4
0.25” Faston
J1 mates with Molex Housing PN 09-50-1031
J2 mates with Molex Housing PN 09-50-1041
and both with Molex Series 5194 Crimp Terminals
Notes
1. All dimensions in inches (mm).
2. Weight: 0.22 lbs (100 g)
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
Thermal Considerations (All ECS25ꢀ60 Models)
In order to ensure safe and reliable operation of the PSU in the most adverse
Temperature Measurements (Ambient ≤50 °C)
conditions permitted in the end-use equipment, the temperature of the
components listed in the table must not be exceeded. See mechanical
drawings for component locations. Temperature should be monitored using
K type thermocouples placed on the hottest part of the component (out of
any direct air flow).
Component
Max Temperature º C
110 °C
T1
Q1
C5
110 °C
100 °C
100 °C
C18
08-Oct-13
相关型号: