DRS240PS24 [XPPOWER]

AC-DC Power Supplies; AC- DC电源
DRS240PS24
型号: DRS240PS24
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Power Supplies
AC- DC电源

文件: 总2页 (文件大小:71K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
80-240 Watts  
xppower.com  
DRS80-240 Series  
Ultra Slim Cases  
150% Peak Load for 4 seconds  
Wide Output Adjustment Range  
High Efficiency – Up to 92%  
12 V, 24 V & 48 V Versions  
Low Output Ripple & Noise  
-20 ºC to 70 ºC Operating Temperature  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
• 85-264 VAC  
• 47-63 Hz  
Efficiency  
Isolation  
• See table  
• 3000 VAC Input to Output  
1500 VAC Input to Ground  
500 VDC Output to Ground  
• 80 W: 2 A at 85 VAC  
120 W: 2 A at 85 VAC  
240 W: 4 A at 85 VAC  
Switching Frequency  
• DRS80 60-300 kHz variable  
Inrush Current  
Power Factor  
• 30 A max at 230 VAC  
DRS120 & DRS240 100 kHz typical PFC  
& main converter  
• DRS80 0.6 typical  
DRS120 & 240 0.95 typical  
Conforms to EN61000-3-2 Class A.  
Signals  
MTBF  
• DRS120 & 240: DC OK Volt free contacts  
• >200 kHrs to MIL HDBK217F  
Earth Leakage Current • 1.5 mA maximum  
Environmental  
Output  
Operating Temperature • -20 ºC to +70 ºC (see derating curves)  
Output Voltage  
• See table  
• See table  
Cooling  
• Natural covection  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
Operating Humidity  
Storage Temperature  
Shock  
• 5-95ꢀ RH, non-condensing  
• -25 °C to +85 °C  
1ꢀ at 50ꢀ load  
• No minimum load required  
• 1 s maximum  
• IEC68-2-6, 30 g, 11ms half sine, 3 times in  
each of 6 axes  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
• 20 ms typical  
Vibration  
• IEC68-2-27, 10-500 Hz, 2 g 10  
mins/sweep. 60 mins for each of 3 axes  
• 20 ms minimum at full load and 115 VAC  
Line Regulation  
Load Regulation  
Transient Response  
0.5ꢀ  
1ꢀ  
EMC & Safety  
Emissions  
• EN55022, class B conducted & radiated  
• EN61000-3-2, class A  
• 10ꢀ maximum deviation, recovering to  
less than 1ꢀ within 500 µs for 50ꢀ step  
load change at 0.2 A/µs  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
• EN61000-3-3  
Ripple & Noise  
• 100 mV pk-pk maximum, measured with  
20 MHz BW  
• EN61000-4-2, 4 KV Contact,  
8 KV Air Discharge  
Overvoltage Protection • 12 V output: 16.5-18 V, 24 V output:  
Radiated Immunity  
EFT/Burst  
• EN61000-4-3, 3 V/m Perf Criteria A  
• EN61000-4-4, level 2 Perf Criteria A  
29-31.2 V, 48 V output: 57.6-62.4 V  
Overload Protection  
• 110-150ꢀ of rated current, constant  
current limit  
Surge  
• EN61000-4-5, Installation Class 3  
Perf Criteria B  
Short Circuit Protection Trip and restart (hiccup mode)  
Conducted Immunity  
Dips & Interruptions  
• EN61000-4-6, 3 V Perf Criteria A  
Temperature  
Coefficient  
0.02ꢀ/°C  
• EN61000-4-11, 30ꢀ 10 ms,  
60ꢀ 100 ms, 100ꢀ 5000 ms  
Perf Criteria A, B, B  
Safety Approvals  
• UL508, EN60950, UL1604 Pending  
DRS80-240  
Models and Ratings  
Output Voltage  
Output Power  
Output Voltage Trim  
12-15 V  
Output Current(1)  
6.0 A  
Typical Efficiency(2)  
Model Number  
DRS80US12  
DRS80US24  
DRS80US48  
DRS120PS12  
DRS120PS24  
DRS120PS48  
DRS240PS12  
DRS240PS24  
DRS240PS48  
12 V  
72 W  
80 W  
89ꢀ  
90ꢀ  
91ꢀ  
89ꢀ  
91ꢀ  
91ꢀ  
89ꢀ  
92ꢀ  
92ꢀ  
24 V  
24-28 V  
3.4 A  
48 V  
80 W  
48-56 V  
1.7 A  
12 V  
96 W  
12-15 V  
8.0 A  
24 V  
120 W  
120 W  
180 W  
240 W  
240 W  
24-28 V  
5.0 A  
48 V  
48-56 V  
2.5 A  
12 V  
12-15 V  
15.0 A  
10.0 A  
5.0 A  
24 V  
24-28 V  
48 V  
48-56 V  
Notes  
1. At nominal output voltage. Derate as output voltage increases.  
2. At 230 VAC input, 100% load  
Mechanical Details  
W
W
L
Pin Connections  
Conn Pin  
Designation  
Neutral  
1
1
6
4
1
2
3
6
5
4
3
2
1
DC Output  
DC Output  
AC  
Line  
Input  
Ground  
DC OK*  
DC OK*  
Negative  
Negative  
Positive  
Positive  
DC OK  
DC OK  
OVERLOAD  
OVERLOAD  
H
H
DC  
DRS80  
DRS120-240  
Output  
* Available on DRS120 and 240,  
DRS80 has a 4 way output  
connector  
AC Input  
3
AC Input  
1
1
3
Sizes (inches/mm)  
L
Weight  
lbs (g)  
Wire sizes  
Model  
AWG (mm2)  
W
H
DRS80  
1.26 (32)  
4.00 (102) 4.88 (124) 0.92 (420)  
AWG24-10 (0.2-5.3 mm2)  
AWG24-10 (0.2-5.3 mm2)  
AWG24-10 (0.2-5.3 mm2)  
DRS120  
DRS240  
1.57 (40) 4.60 (113.3) 4.88 (124) 1.37 (620)  
2.36 (60) 4.60 (113.3) 4.88 (124) 1.98 (900)  
Derating Curves  
DRS80 & DRS120  
DRS240  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
20  
30  
Ambient Temp (˚C)  
40  
20  
30  
-20  
0
10  
50  
60  
70  
40  
-20  
-10  
0
10  
50  
60  
70  
Ambient Temp (˚C)  
DC OK  
DCOK  
DCOK  
Open = Output fail  
Contact Rating: 0.3 A at 60 VDC  
500 VDC isolation  
Available on DRS120 & DRS240 models.  
Closed = Output good  
18-Nov-08  

相关型号:

DRS240PS48

AC-DC Power Supplies
XPPOWER

DRS2412

1.25 WATT
POWER-ONE

DRS2412

DC-DC Regulated Power Supply Module, 1 Output
BEL

DRS2412-1H

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL

DRS2412-1V

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL

DRS2412-2H

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL

DRS2412-2V

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL

DRS2412-3H

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL

DRS2412-3V

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL

DRS2412-81H

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL

DRS2412-81V

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL

DRS2412-82H

DC-DC Regulated Power Supply Module, 1 Output, 1.25W, Hybrid
BEL