X25F047V [XICOR]
SPI SerialFlash with Block Lock TM Protection; SPI SerialFlash带座锁TM保护型号: | X25F047V |
厂家: | XICOR INC. |
描述: | SPI SerialFlash with Block Lock TM Protection |
文件: | 总14页 (文件大小:74K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
4K
512 x 8 Bit
X25F047
SPI SerialFlash with Block LockTM Protection
FEATURES
DESCRIPTION
• 1MHz Clock Rate
• SPI Modes (0,0 & 1,1)
• 512 x 8 Bits
—16 Byte Small Sector Program Mode
• Low Power CMOS
The X25F047 is a CMOS 4K-bit SerialFlash, internally
organized as 512 x 8. The X25F047 features a Serial
Peripheral Interface (SPI) and software protocol
allowing operation on a simple four-wire bus. The bus
signals are a clock input (SCK) plus separate data in (SI)
and data out (SO) lines. Access to the device is
controlled through a chip select (CS) input, allowing any
number of devices to share the same bus.
—<1µA Standby Current
—<3mA Active Current during Program
—<400µA Active Current during Read
• 1.8V to 3.6V or 5V “Univolt” Read and Program
Power Supply Versions
There are eight options for programmable, nonvolatile,
Block Lock Protection available to the end user. These
options are implemented via special instructions
programmed to the part. The X25F047 also features a
PP pin that can be used for hardwire protection of the
part, disabling all programming attempts, as well as a
ProgramEnableLatchthatmustbesetbeforeaprogram
operation can be initiated.
• Block Lock Protection
—Block Lock Protect 0, any 1/4, 1st 1/2, First or
Last Sector of SerialFlash Array
• Built-in Inadvertent Program Protection
—Power-Up/Power-Down Protection Circuitry
—Program Enable Latch
—Program Protect Pin
• Self-Timed Program Cycle
—5ms Program Cycle Time (Typical)
• High Reliability
The X25F047 utilizes Xicor’s proprietary Direct WriteTM
cell, providing a minimum endurance of 100,000 cycles
per sector and a minimum data retention of 100 years.
—Endurance: 100,000 Cycles/Byte
—Data Retention: 100Years
—ESD: 2000V on all pins
• 8-Lead SOIC Package
• 8-Lead MSOP Package
• 8-Lead TSSOP Package
• 8-Pin Mini-DIP Package
FUNCTIONAL DIAGRAM
DATA REGISTER
Y DECODE LOGIC
SI
SO
16
8
COMMAND
DECODE
AND
CONTROL
LOGIC
X
32
SCK
CS
DECODE
LOGIC
SERIALFLASH
ARRAY
(512 x 8)
HIGH VOLTAGE
CONTROL
PP
PROGRAM CONTROL LOGIC
7005 FRM 01.3
Xicor, Inc. 1994, 1995, 1996 Patents Pending
7005-0.9 5/7/97 T4/C0/D1
Characteristics subject to change without notice
1
X25F047
PIN DESCRIPTIONS
Serial Output (SO)
PIN CONFIGURATION
Not to scale
8-LEAD SOIC/DIP
SO is a push/pull serial data output pin. During a read
cycle, data is shifted out on this pin. Data is clocked out
by the falling edge of the serial clock.
V
CS
SO
PP
1
2
3
4
8
7
6
5
CC
NC
SCK
SI
*0.197"
0.120"
0.122"
X25F047
Serial Input (SI)
V
SS
SI is a serial data input pin. All opcodes, byte addresses,
and data to be programmed to the memory are input on
this pin. Data is latched by the rising edge of the serial
clock.
*0.244"
8-LEAD MSOP
V
SO
CS
1
2
3
4
8
7
6
5
Serial Clock (SCK)
CC
NC
SI
The Serial Clock controls the serial bus timing for data
input and output. Opcodes, addresses, or data present
on the SI pin are latched on the rising edge of the clock
input, while data on the SO pin change after the falling
edge of the clock input.
X25F047
V
SS
PP
SCK
0.193"
8-LEAD TSSOP
Chip Select (CS)
When CS is HIGH, the X25F047 is deselected and the
SO output pin is at high impedance and unless a nonvol-
atile write cycle is underway, the X25F047 will be in the
standby power mode. CS LOW enables the X25F047,
placing it in the active power mode. It should be noted
that after power-up, a HIGH to LOW transition on CS is
required prior to the start of any operation.
NC
SCK
SI
1
2
3
4
8
7
6
5
V
CC
CS
X25F047
V
SS
PP
SO
0.252"
*SOIC Measurement
7005 FRM 02
Program Protect (PP)
PRINCIPLES OF OPERATION
When PP is LOW, nonvolatile writes to the X25F047 are
disabled, but the part otherwise functions normally.When
PP is held HIGH, all functions, including nonvolatile
writes, operate normally. PP going LOW while CS is still
LOW will interrupt a programming cycle to the X25F047.
If the nonvolatile write cycle has already been initiated,
PP going low will have no affect on this cycle.
The X25F047 is a 512 x 8 SerialFlash designed to inter-
face directly with the synchronous Serial Peripheral Inter-
face (SPI) of many popular microcontroller families.
The X25F047 contains an 8-bit instruction register. It is
accessed via the SI input, with data being clocked in on
the rising edge of SCK. CS must be LOW and the PP
input must be HIGH during the entire operation. Table 1
contains a list of the instructions and their opcodes. All
instructions, addresses and data are transferred MSB first.
PIN NAMES
Symbol
CS
Description
Chip Select Input
Data input is sampled on the first rising edge of SCK
after CS goes LOW. SCK is static, allowing the user to
stop the clock and then start it again to resume opera-
tions where left off.
SO
Serial Output
SI
Serial Input
SCK
PP
Serial Clock Input
Program Protect Input
Program Enable Latch
The X25F047 contains a “Program Enable” latch. This
latch must be SET before a program operation is initi-
ated. The PREN instruction will set the latch and the
PRDI instruction will reset the latch (Figure 4). This latch
is automatically reset upon a power-up condition and
after the completion of a sector program cycle.
V
Ground
SS
V
Supply Voltage
No Connect
CC
NC
7005 FRM T01
2
X25F047
Block Lock Protection
clocks. CS must go LOW and remain LOW for the dura-
tion of the operation. The host must program 16 bytes in
each write with the restriction that these bytes reside on
one sector. If the address counter reaches the end of the
sector and the clock continues, or if fewer than 16 bytes
are clocked in, the contents of the sector cannot be guar-
anteed.
There are eight Block Lock Protection options. The pre-
defined blocks and associated address ranges are pro-
tected by programming the appropriate two byte
Program Status instruction to the device (Table 1 and
Figure 6). Once a Block Lock protect instruction has
been completed, that Block Lock Protection setup is held
in a nonvolatile Status Register (Figure 1) until the next
Program Status instruction is issued. The sections of the
memory array that are Block Lock protected can be read
but not programmed until Block Lock Protection is
removed or changed.
For a sector program operation to be completed, CS can
only be brought HIGH after bit 0 of the last data byte to
be programmed is clocked in. If it is brought HIGH at any
other time, the program operation will not be completed.
(Figure 5)
Figure 1. Status Register/Block Lock Protection Byte
Read Status Operation
If there is not a nonvolatile write in progress, the Read
Status instruction returns the Block Lock Protection byte
from the Status Register which contains the Block Lock
Protection bits BL2-BL0 (Figure 1). The Block Lock Pro-
tection bits define the Block Lock Protection condition
(Figure 1 and Table1). The other bits are reserved and
will return "0’s" when read (Figure 3).
7
0
6
0
5
0
4
0
3
0
2
1
0
BL2 BL1 BL0
Note: Bits [7:3] specified to be “0’s”
7005 FRM T02.1
Read Sequence
When reading from the SerialFlash memory array, CS is
first pulled LOW to select the device. The 8-bit READ
instruction is transmitted to the X25F047, followed by the
16-bit address, of which the last 9 bits are used (bits
[15:9] specified to be "0’s"). After the READ opcode and
address are sent, the data stored in the memory at the
selected address is shifted out on the SO line. The data
stored in memory at the next address can be read
sequentially by continuing to provide clock pulses. The
address is automatically incremented to the next higher
address after each byte of data is shifted out. When the
highest address is reached (01FFh), the address counter
rolls over to address 0000h, allowing the read cycle to be
continued indefinitely. The read operation is terminated
by taking CS HIGH (Figure 2).
If a nonvolatile write is in progress, the Read Status
instruction returns the status of the internal write opera-
tion on SO. When the nonvolatile write cycle is com-
pleted, the status register data is again read out.
During a nonvolatile write in progress, the SO pin will be
set HIGH. At the end of the nonvolatile write cycle, SO is
set to output the current bit from the status register.
Clocking SCK is valid during a nonvolatile write in
progress, but is not necessary. If the SCK line is clocked,
the pointer to the status register is also clocked, even
though the SO pin shows the status of the nonvolatile
write operation (Figure 3). When the pointer reaches the
end of the eight bit status register, it “rolls over” to the first
bit of the register.
Sector Program Sequence
Program Status Operation
Prior to any attempt to program data into the X25F047,
the “Program Enable” latch must first be set by issuing
the PREN instruction (Table 1 and Figure 4). CS is first
taken LOW. Then the PREN instruction is clocked into
the X25F047. After all eight bits of the instruction are
transmitted, CS must then be taken HIGH. If the user
continues the program operation without taking CS HIGH
after issuing the PREN instruction, the program opera-
tion will be ignored.
Prior to any attempt to perform a Program Status Opera-
tion, the PREN instruction must first be issued. This
instruction sets the “Program Enable” latch and allows
the part to respond to a Program Status sequence (Fig-
ure 6). The Program Status instruction follows and con-
sists of one command byte followed by one Block Lock
Protection byte (Figure 1). This byte contains the Block
Lock Protection bits BL2-BL0. The rest of the bits [7:3]
are unused and must be programmed as “0’s”. Bringing
CS HIGH after the two byte Program Status instruction
initiates a nonvolatile write to the Status Register. Pro-
gramming more than one byte to the Status Register will
overwrite the previously programmed Block Lock Protec-
tion byte (Table 1).
To program data to the SerialFlash memory array, the
user then issues the PROGRAM instruction, followed by
the 16 bit address of the first location in the sector and
then the 16 bytes of data to be programmed. Only the last
9 bits of the address are used and bits [15:9] are speci-
fied to be "0’s". The entire write operation takes 152
3
X25F047
Data Protection
Operational Notes
The following circuitry has been included to prevent inad-
vertant programming of data:
The X25F047 powers up in the following state:
• The device is in the low power, standby state.
• A HIGH to LOW transition on CS is required to enter
an active state and receive an instruction.
• SO pin is at high impedance.
• The “Program Enable” latch is reset upon power-up.
• A PREN instruction must be issued to set the “Program
Enable” latch.
• CS must come HIGH at the proper clock count in order
to start a program cycle.
• The “Program Enable” latch is reset.
Table 1. Instruction Set and Block Lock Protection Byte Definition
Instruction
Format*
0000 0110
0000 0100
0000 0001
Instruction Name and Operation
PREN: Set the Program Enable Latch (Program Enable Operation)
PRDI: Reset the Program Enable Latch (Program Disable Operation)
PROGRAM STATUS Instruction - followed by:
Block Lock Protection Byte: (Figure 1)
0000 0000 --->NO PROTECT: ---------------------------------->None of the Array
0000 0001 --->PROTECT Q1: --- 0000h - 007Fh ---------->Lower Quadrant (Q1)
0000 0010 --->PROTECT Q2: --- 0080h - 00FFh----------->Q2
0000 0011 --->PROTECT Q3: --- 0100h - 017Fh----------->Q3
0000 0100 --->PROTECT Q4: --- 0180h - 01FFh----------->Upper Quadrant (Q4)
0000 0101 --->PROTECT H1: --- 0000h - 00FFh----------->Lower Half of the Array (H1)
0000 0110 --->PROTECT S0: --- 0000h - 000Fh----------->Lower Sector (S0)
0000 0111 --->PROTECT Sn: --- 01F0h - 01FFh----------->Upper Sector (Sn)
0000 0101
0000 0010
0000 0011
READ STATUS: Reads Block Lock Protection & nonvolatile write in progress status on SO Pin
PROGRAM: Program operation followed by address and data
READ: Read operation followed by address
7005 FRM T03.1
*Instructions are shown with MSB in leftmost position. Instructions are transferred MSB first.
Figure 2. Read Operation Sequence
CS
0
1
2
3
4
5
6
7
8
9
20 21 22 23 24 25 26 27 28 29 30
SCK
SI
READ INSTRUCTION
(1 BYTE)
BYTE ADDRESS (2 BYTE)
15 14 0
DATA OUT
3
2
1
HIGH IMPEDANCE
7
6
5
4
3
2
1
0
SO
7005 FRM F03.1
4
X25F047
Figure 3. Read Status Operation Sequence
CS
0
1
2
3
4
5
6
7
SCK
SI
...
...
...
READ STATUS
INSTRUCTION
NONVOLATILE WRITE IN PROGRESS
B
L
1
B
L
2
B
L
0
SO
SO HIGH DURING
NONVOLATILE
WRITE CYCLE
SO = STATUS REG BIT
WHEN NO NONVOLATILE
WRITE CYCLE
7005 FRM 04.2
Figure 4. Program Enable/Program Disable Sequence
CS
0
1
2
3
4
5
6
7
SCK
INSTRUCTION
(1 BYTE)
SI
HIGH IMPEDANCE
SO
7005 FRM 05.1
5
X25F047
Figure 5. Sector Program Operation Sequence
CS
0
1
2
3
4
5
6
7
8
9
10
20 21 22 23 24 25 26 27 28 29 30 31
SCK
SI
PROGRAM
INSTRUCTION
BYTE ADDRESS
(2 BYTE)
DATA BYTE 1
15 14 13
3
2
1
0
7
6
5
4
3
2
1
0
CS
SCK
SI
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
DATA BYTE 2
DATA BYTE 3
DATA BYTE 16
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
6
5
4
3
2
1
0
7005 FRM 07.3
Figure 6. Program Status Operation Sequence
CS
0
1
2
3
4
5
6
7
8
0
9
0
10 11 12 13 14 15
BLOCK LOCK
SCK
PROGRAM STATUS
INSTRUCTION
PROTECTION BYTE
B
L
2
B
L
1
B
L
0
SI
0
0
0
HIGH IMPEDANCE
SO
7005 ILL F08.2
ABSOLUTE MAXIMUM RATINGS*
*COMMENT
Temperature under Bias ...................–65°C to +135°C
Storage Temperature........................–65°C to +150°C
Voltage on any Pin with
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
Respect to V .................................... –1V to +7V
SS
D.C. Output Current..............................................5mA
Lead Temperature
(Soldering, 10 seconds) ..............................300°C
6
X25F047
RECOMMENDED OPERATING CONDITIONS
Supply Voltage
X25F047
Limits
Temperature
Commercial
Industrial
Min.
0°C
Max.
+70°C
+85°C
1.8V to 3.6V
4.5V to 5.5V
X25F047-5
–40°C
7005 FRM T05
7005 FRM T04
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions, unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max.
Units
mA SCK = V x 0.1/V
CC
Test Conditions
I
V
V
V
Read Current (Active)
1
x 0.9 @ 1MHz,
CC1
CC
CC
CC
CC
SO = Open, CS = V
SS
I
Write Current (Active)
3
mA SCK = V x 0.1/V
CC
x 0.9 @ 1MHz,
CC2
CC
SO = Open, CS = V
SS
I
I
I
Supply Current (Standby)
1
µA
µA
µA
V
CS = V - 0.1, V = V or V
SB
CC
IN
SS
CC
Input Leakage Current
Output Leakage Current
Input LOW Voltage
10
10
V
= V to V
SS
LI
IN
CC
V
= V to V
LO
OUT
SS
CC
(1)
–0.5
V
x 0.3
CC
V
V
V
V
V
V
V
V
IL
(1)
IH
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
V
V
V
V
x 0.7
V
+ 0.5
CC
V
CC
CC
CC
CC
0.4
V
V
V
V
V
V
V
= 5.5V, I = 2.1mA
OL
OL1
OH1
OL2
OH2
OL3
OH3
CC
CC
CC
CC
CC
CC
– 0.8
– 0.4
– 0.2
V
= 5.5V, I
= –1.0mA
OH
0.4
0.4
V
= 3.6V, I = 1.0mA
OL
V
= 3.6V, I
= –0.4mA
OH
V
= 1.8V, I = 0.5mA
OL
V
= 1.8V, I
= –0.25mA
OH
7005 FRM T06
POWER-UPTIMING
Symbol
Parameter
Power-up to Read Operation
Power-up to Write Operation
Min.
Max.
Units
(3)
PUR
1
5
ms
t
(3)
PUW
ms
t
7005 FRM T07.1
CAPACITANCE T = +25°C, f = 1MHz, V =5V.
A
CC
Symbol
Parameter
Max.
Units
Conditions
= 0V
(2)
C
Output Capacitance (SO)
Input Capacitance (SCK, SI, CS, PP)
8
6
pF
V
OUT
OUT
(2)
C
pF
V
= 0V
IN
IN
7005 FRM T08
Notes: (1) V Min. and V Max. are for reference only and are not 100% tested.
IL
IH
(2) This parameter is periodically sampled and not 100% tested.
(3) t and t are the delays required from the time V is stable until the specified operation can be initiated. These parameters
PUR
PUW
CC
are periodically sampled and not 100% tested.
7
X25F047
A.C. TEST CONDITIONS
EQUIVALENT A.C. LOAD CIRCUIT
Input Pulse Levels
V
x 0.1 to V x 0.9
CC
CC
5V
3.3V
Input Rise and Fall Times
10ns
2061Ω
OUTPUT
3025Ω
2696Ω
OUTPUT
5288Ω
Input and Output Timing Level
V
X 0.5
CC
7005 FRM T09
30pF
30pF
7005 FRM 09.1
A.C. CHARACTERISTICS (Over the recommended operating conditions, unless otherwise specified.)
Data Input Timing
Symbol
SCK
CYC
LEAD
LAG
WH
Parameter
Min.
Max.
Units
f
t
t
t
t
t
t
t
Clock Frequency
0
1
MHz
Cycle Time
1000
500
500
400
400
100
100
ns
ns
ns
ns
ns
ns
ns
µs
CS Lead Time
CS Lag Time
Clock HIGH Time
Clock LOW Time
Data Setup Time
Data Hold Time
Data In Rise Time
WL
SU
H
(4)
RI
2
2
t
(4)
FI
Data In Fall Time
µs
t
t
CS Deselect Time
Write Cycle Time
2.0
µs
CS
(5)
WC
10
ms
t
7005 FRM T10
Data Output Timing
Symbol
Parameter
Min.
Max.
Units
f
t
t
t
Clock Frequency
0
1
MHz
ns
SCK
DIS
V
Output Disable Time
Output Valid from Clock LOW
Output Hold Time
500
400
ns
0
ns
HO
(4)
Output Rise Time
300
300
ns
t
RO
(4)
Output Fall Time
ns
t
FO
7005 FRM T11
Notes: (4) This parameter is periodically sampled and not 100% tested.
(5) t is the time from the rising edge of CS after a valid program sequence has been sent to the end of the self-timed internal nonvol-
WC
atile write cycle.
8
X25F047
Figure 7. Serial Output Timing
CS
tCYC
tLAG
tWH
SCK
tV
MSB OUT
tHO
tWL
tDIS
MSB–1 OUT
LSB OUT
SO
SI
ADDR
LSB IN
7005 FRM 10
Figure 8. Serial Input Timing
tCS
CS
tLEAD
tLAG
SCK
tFI
tSU
tH
tRI
SI
MSB IN
LSB IN
HIGH IMPEDANCE
SO
7005 FRM 11
SYMBOL TABLE
WAVEFORM
INPUTS
OUTPUTS
Must be
steady
Will be
steady
May change
from Low to
High
Will change
from Low to
High
May change
from High to
Low
Will change
from High to
Low
Don’t Care:
Changes
Allowed
Changing:
State Not
Known
N/A
Center Line
is High
Impedance
9
X25F047
PACKAGING INFORMATION
8-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S
0.150 (3.80)
0.158 (4.00)
0.228 (5.80)
0.244 (6.20)
PIN 1 INDEX
PIN 1
0.014 (0.35)
0.019 (0.49)
0.188 (4.78)
0.197 (5.00)
(4X) 7°
0.053 (1.35)
0.069 (1.75)
0.004 (0.19)
0.010 (0.25)
0.050 (1.27)
0.010 (0.25)
0.020 (0.50)
0.050" TYPICAL
X 45°
0.050"
TYPICAL
0° – 8°
0.0075 (0.19)
0.010 (0.25)
0.250"
0.016 (0.410)
0.037 (0.937)
0.030"
TYPICAL
8 PLACES
FOOTPRINT
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
10
X25F047
PACKAGING INFORMATION
8-LEAD MINIATURE SMALL OUTLINE GULLWING PACKAGE TYPE M
0.118 ± 0.002
(3.00 ± 0.05)
0.012 + 0.006 / -0.002
(0.30 + 0.15 / -0.05)
0.0256 (0.65) TYP
R 0.014 (0.36)
0.118 ± 0.002
(3.00 ± 0.05)
0.030 (0.76)
0.0216 (0.55)
7° TYP
0.036 (0.91)
0.032 (0.81)
0.040 ± 0.002
(1.02 ± 0.05)
0.008 (0.20)
0.004 (0.10)
0.150 (3.81)
0.007 (0.18)
0.005 (0.13)
REF.
0.193 (4.90)
REF.
NOTE:
1. ALL DIMENSIONS IN INCHES AND (MILLIMETERS)
3003 FRM 01
11
X25F047
PACKAGING INFORMATION
8-LEAD PLASTIC, TSSOP, PACKAGE TYPE V
.025 (.65) BSC
.169 (4.3)
.252 (6.4) BSC
.177 (4.5)
.114 (2.9)
.122 (3.1)
.047 (1.20)
.0075 (.19)
.002 (.05)
.0118 (.30)
.006 (.15)
.010 (.25)
Gage Plane
0° – 8°
Seating Plane
.019 (.50)
.029 (.75)
DetailA (20X)
.031 (.80)
.041 (1.05)
See Detail “A”
NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
12
X25F047
PACKAGING INFORMATION
8-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P
0.430 (10.92)
0.360 (9.14)
0.260 (6.60)
0.240 (6.10)
PIN 1 INDEX
PIN 1
0.060 (1.52)
0.300
(7.62) REF.
0.020 (0.51)
HALF SHOULDER WIDTH ON
ALL END PINS OPTIONAL
0.145 (3.68)
0.128 (3.25)
SEATING
PLANE
0.025 (0.64)
0.015 (0.38)
0.150 (3.81)
0.125 (3.18)
0.065 (1.65)
0.045 (1.14)
0.110 (2.79)
0.090 (2.29)
0.020 (0.51)
0.016 (0.41)
0.325 (8.25)
0.300 (7.62)
0.015 (0.38)
MAX.
0°
TYP. 0.010 (0.25)
15°
NOTE:
1. ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS)
2. PACKAGE DIMENSIONS EXCLUDE MOLDING FLASH
13
X25F047
ORDERING INFORMATION
X25F047
P
T
–X
V
Range
CC
Device
Blank = 1.8V to 3.6V
5 = 4.5V to 5.5V
Temperature Range
Blank = Commercial = 0°C to +70°C
I = Industrial = –40°C to +85°C
Package
S = 8-Lead SOIC
M = 8-Lead MSOP
V = 8-Lead TSSOP
P = 8-Lead Plastic DIP
Part Mark Convention
8-Lead MSOP
8-Lead TSSOP
8-Lead SOIC/PDIP
Blank = 8-Lead SOIC
P = 8-Lead Plastic DIP
EYWW
XXX
EYWW
5F47XX
X25F047 X
XX
AAH = 1.8 to 3.6V, 0°C to +70°C
AAI = 1.8 to 3.6V, -20°C to +85°C
AAJ = 1.8 to 3.6V, -40°C to +85°C
AAK = 2.5 to 5.5V, 0°C to +70°C
AAL = 2.5 to 5.5V, -40°C to +85°C
AAM = 4.5 to 5.5V, 0°C to +70°C
AAN = 4.5 to 5.5V, -40°C to +85°C
Blank = 1.8 to 3.6V, 0°C to +70°C
I = 1.8 to 3.6V, -40°C to +85°C
AE = 2.5 to 5.5V, 0°C to +70°C
AF = 2.5 to 5.5V, -40°C to +85°C
5 = 4.5 to 5.5V, 0°C to +70°C
I5 = 4.5 to 5.5V, -40°C to +85°C
Blank = 1.8 to 3.6V, 0°C to +70°C
I = 1.8 to 3.6V, -40°C to +85°C
AE = 2.5 to 5.5V, 0°C to +70°C
AF = 2.5 to 5.5V, -40°C to +85°C
5 = 4.5 to 5.5V, 0°C to +70°C
I5 = 4.5 to 5.5V, -40°C to +85°C
LIMITED WARRANTY
Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale only. Xicor, Inc.
makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the
described devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the
right to discontinue production and change specifications and prices at any time and without notice.
Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents,
licenses are implied.
U.S. PATENTS
Xicor products are covered by one or more of the following U.S. Patents: 4,263,664; 4,274,012; 4,300,212; 4,314,265; 4,326,134; 4,393,481;
4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 4,599,706; 4,617,652; 4,668,932; 4,752,912; 4,829, 482; 4,874, 967;
4,883, 976. Foreign patents and additional patents pending.
LIFE RELATED POLICY
In situations where semiconductor component failure may endanger life, system designers using this product should design the system with
appropriate error detection and correction, redundancy and back-up features to prevent such an occurence.
Xicor's products are not authorized for use in critical components in life support devices or systems.
1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain
life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in a significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system, or to affect its safety or effectiveness.
14
相关型号:
©2020 ICPDF网 联系我们和版权申明