LANC2405W5(UW) [WALL]
DC-DC Regulated Power Supply Module,;型号: | LANC2405W5(UW) |
厂家: | WALL INDUSTRIES,INC. |
描述: | DC-DC Regulated Power Supply Module, |
文件: | 总5页 (文件大小:490K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
LANCW5 Series
Single and Dual Outputs
2:1 and 4:1 Wide Input Voltage
Up to 6 Watts DC/DC Converters
Rev. E
APPLICATIONS
● Wireless Network
FEATURES
● Single and Dual Outputs
● Telecom/Datacom
● High Efficiency up to 84%
● Industry Control Systems
● Measurement Equipment
● Semiconductor Equipment
● Standard 1.25 x 0.8 x 0.4 Inches
● Fixed Switching Frequency (300KHz)
● 2:1 and 4:1 Ultra Wide Input Voltage Ranges
● Compliant to RoHS EU Directive 2002/95/EC
● UL60950-1, EN60950-1, and IEC60950-1 Licensed
● Standard 24 Pin DIP Package and SMT Type Package
● CE Mark meets 2006/95/EC, 93/68/EEC, and 2004/108/EC
DESCRIPTION
The LANCW5 series of DC/DC converters offers up to 6 watts of output power in an IC compatible 24 pin DIP configuration. The LANCW5 series has a 2:1
(W) wide input voltage of 9-18, 18-36, and 36-75VDC. The LANCW5 series also has a 4:1 (UW) ultra wide input range of 9-36 and 18-75VDC. This series is
intended to provide power and isolation for applications requiring high power density. Some features include 1600VDC isolation, short circuit protection, and
five-sided shielding. Also available are SMT type (suffix "S") and I type (operating temperature: -40°C~+85°C without derating- add suffix "I").
SPECIFICATIONS: LANCW5 Series
All specifications apply @ 25°C ambient unless otherwise noted
INPUT SPECIFICATIONS
PROTECTION SPECIFICATIONS
Input Voltage Range
Over Load Protection (% of full load at nominal input).................. 170% typ.
Short Circuit Protection................................Continuous, automatic recovery
LANCW5 .........................12V nominal input............................9-18VDC
24V nominal input..........................18-36VDC
48V nominal input..........................36-75VDC
ENVIRONMENTAL SPECIFICATIONS
LANCUW5.......................24V nominal input............................9-36VDC
48V nominal input..........................18-75VDC
Operating Temperature
Standard....................................................-25°C to +85°C (w/ derating)
“I” (See Notes 6 & 9).............................. -40°C to +85°C (w/o derating)
“I” (UW Series)..........................................-40°C to +85°C (w/ derating)
Input Filter ......................................................................................... Pi Type
Input Surge Voltage (100ms max) .......12V input............................36VDC
24V input............................50VDC
Storage Temperature ........................................................... -55°C ~ +105°C
48V input..........................100VDC
Maximum Case Temperature..................Standard .......................... +100°C
“I” suffix............................. +105°C
Input Reflected Ripple Current (nominal Vin and full load) ...........20mAp-p
Start Up Time (nominal Vin and constant resistive load) ...........450ms typ.
Relative Humidity (non-condensing) ...................................... 5% to 95% RH
Thermal Impedance (Natural Convection)...................................20°C / Watt
Thermal Shock....................................................................... MIL-STD-810F
Vibration .................................10~55Hz, 10G, 30 minutes along X, Y, and Z
MTBF (See Note 1).........BELLCORE TR-NWT-000332 ......3.165 x 106 hrs
MIL-HDBK-217F............................1.631 x 106 hrs
OUTPUT SPECIFICATIONS
Output Voltage................................................................................see table
Voltage Accuracy (nominal Vin and full load) ........................................±1%
Output Current ................................................................................see table
Output Power ............................................................................ 5 watts max.
Line Regulation (LL to HL at FL) .........................................................±0.2%
PHYSICAL SPECIFICATIONS
Weight ..................................... DIP type.....................................0.55oz (16g)
SMT type..................................0.63oz (18g)
Load Regulation (no load to full load) .......Single Output................. ±0.5%
Dual Output.........................±1%
Dimensions ................... 1.25 x 0.80 x 0.40 inches (31.8 x 20.3 x 10.2 mm)
Case Material................................................................Nickel-coated copper
Base Material ....................................................Non-conductive black plastic
Potting material................................................................... Epoxy (UL94-V0)
Shielding .......................................................................................five – sided
Cross Regulation (Dual) (Asymmetrical load 25% / 100% FL) .............±5%
Minimum Load ..........................................................................................0%
Ripple/Noise (20 MHz BW)............................................................ 50mVp-p
Temperature Coefficient................................................... ±0.02% / °C max.
Transient Response Recovery Time (25% load step)........................200µs
SAFETY & EMC
Approvals and Standards ...............IEC60950-1, UL60950-1(12), EN60950-1
GENERAL SPECIFICATIONS
Efficiency.........................................................................................see table
Switching Frequency .................................................................300KHz typ.
EMI (See Note 8) ................EN55022................................................Class A
Air
± 8KV
………………Perf. Criteria A
ESD......EN61000-4-2……….
Contact ± 6KV
Isolation Voltage
Input to Output ...............................................................1600VDC min.
Input (Output) to Case (DIP) .........................................1600VDC min.
Input (Output) to Case (SMT)........................................1000VDC min.
Radiated Immunity..............EN61000-4-3 ................10V/m Perf. Criteria A
Fast Transient.....................EN61000-4-4 ................. ±2KV Perf. Criteria B
Surge (See Note 7).............EN61000-4-5 ................ .±1KV Perf. Criteria B
Conducted Immunity...........EN61000-4-6 .............10 Vrms Perf. Criteria A
Isolation Resistance............................................................... 109 ohms min.
Isolation Capacitance ................................................................ 300pF max.
Due to advances in technology, specifications subject to change without notice
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
7/11/2019
Page 1 of 5
LANCW5 Series
Single and Dual Outputs
2:1 and 4:1 Wide Input Voltage
Up to 6 Watts DC/DC Converters
Rev. E
MODEL SELECTION TABLE
Input Current
Output
Voltage
Output
Current
Ripple &
Noise (4)
Efficiency Output Capacitor(5)
UL
Model Number
Input Range
(4)
Power
Load Max Approval (12)
No
Full
Load(3)
Load(2)
LANC1233W5
LANC1205W5
LANC1212W5
LANC1215W5
LANC1205DW5
LANC1212DW5
LANC1215DW5
9–18 VDC
9–18 VDC
9–18 VDC
9–18 VDC
9–18 VDC
9–18 VDC
9–18 VDC
3.3 VDC
5 VDC
1000mA
1000mA
470mA
10mA
10mA
10mA
10mA
15mA
20mA
15mA
76%
78%
82%
81%
78%
81%
84%
3.3W
5W
2200µF
1000µF
220µF
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
382mA
563mA
603mA
649mA
563mA
597mA
594mA
12 VDC
15 VDC
±5 VDC
±12 VDC
±15 VDC
5.64W
6W
400mA
150µF
±500mA
±230mA
±190mA
5W
± 68µF
± 100µF
± 68µF
5.5W
5.7W
10mA
(5mA)
15mA
194mA
(191mA)
285mA
LANC2433W5 (UW)
18–36 (9–36) VDC
3.3 VDC
1000mA
75% (76%)
3.3W
2200µF
UL60950-1
50mVp-p
LANC2405W5 (UW)
LANC2406UW5
18–36 (9–36) VDC
9–36 VDC
5 VDC
6 VDC
1000mA 50mVp-p
77% (79%)
79%
5W
5W
1000µF
690µF
220µF
UL60950-1
-
(10mA) (278mA)
833mA
470mA
50mVp-p
50mVp-p
-
278mA
15mA
(5mA)
15mA
(10mA) (312mA)
15mA 274mA
(10mA) (282mA)
20mA 288mA
(10mA) (295mA)
20mA 308mA
(10mA) (297mA)
305mA
(305mA)
325mA
LANC2412W5 (UW)
18–36 (9–36) VDC
12 VDC
81% (81%) 5.64W
UL60950-1
LANC2415W5 (UW)
18–36 (9–36) VDC
15 VDC
±5 VDC
400mA
50mVp-p
81% (84%)
80% (78%)
84% (82%)
81% (84%)
74% (73%)
77% (79%)
6W
5W
150µF
± 680µF
± 100µF
± 68µF
2200µF
1000µF
220µF
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
UL60950-1
LANC2405DW5 (UW) 18–36 (9–36) VDC
LANC2412DW5 (UW) 18–36 (9–36) VDC
LANC2415DW5 (UW) 18–36 (9–36) VDC
±500mA 50mVp-p
±230mA 50mVp-p
±190mA 50mVp-p
1000mA 50mVp-p
1000mA 50mVp-p
±12 VDC
±15 VDC
5.5W
5.7W
3.3W
5W
10mA
(5mA)
10mA
98mA
(100mA)
143mA
LANC24833W5 (UW) 36–75 (18–75) VDC 3.3 VDC
LANC4805W5 (UW)
LANC4812W5 (UW)
LANC4815W5 (UW)
36–75 (18–75) VDC
36–75 (18–75) VDC
36–75 (18–75) VDC
5 VDC
12 VDC
15 VDC
±5 VDC
(10mA) (138mA)
10mA 151mA
(10mA) (155mA)
10mA 162mA
(10mA) (160mA)
10mA 141mA
(10mA) (145mA)
5mA 147mA
(10mA) (151mA)
10mA 150mA
(10mA) (156mA)
470mA
50mVp-p
50mVp-p
82% (80%) 5.64W
400mA
81% (82%)
78% (76%)
82% (80%)
83% (80%)
6W
5W
150µF
LANC4805DW5 (UW) 36–75 (18–75) VDC
±500mA 50mVp-p
±230mA 50mVp-p
±190mA 50mVp-p
± 68µF
± 100µF
± 68µF
LANC4812DW5 (UW) 36–75 (18–75) VDC ±12 VDC
LANC4815DW5 (UW) 36–75 (18–75) VDC ±15 VDC
5.5W
5.7W
NOTES
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @ Ta=25°C, Full load (Ground, benign, controlled environment).
2. Maximum value at nominal input voltage and full load of standard type.
3. Typical value at nominal input voltage and no load.
4. Typical value at nominal input voltage and full load.
5. Test by minimum Vin and constant resistive load.
6. The industrial “I” suffix for 2:1 version is more efficient, therefore, it can be operated in a more extensive temperature range than
standard and I suffix 4:1 input versions.
7. An external filter capacitor is required if the module has to meet EN61000-4-5. The filter capacitor suggested is Nippon chemi-com KY
series, 220μF/100V, ESR 48mΩ.
8. The LANCW5 Series can meet EMC EN55022 Class A and Class B with an external filter in parallel with the input pins. See page 3 for filter suggestions.
9. There is no pin at PIN10 & PIN15 for LANC5UW series.
10. For industrial temperature range add the suffix “I” to the model number.
11. For SMT type add the suffix “S” to the model number.
12. UL approval can be added to any products not currently listed if required.
*Due to advances in technology, specifications subject to change without notice.
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
7/11/2019
Page 2 of 5
LANCW5 Series
Single and Dual Outputs
2:1 and 4:1 Wide Input Voltage
Up to 6 Watts DC/DC Converters
Rev. E
DERATING CURVE
LANC4805W5 DERATING CURVE
“I” Version
120
100
80
60
40
20
0
-40 -25 -10
5
20
35 50
65 70.1
95 105
EFFICIENCY GRAPHS
AMBIENT TEMPERATURE (°C)
LANC4805W5
Efficiency VS Output Load
Efficiency VS Input Voltage
90
85
80
75
70
65
60
55
50
45
40
83
81
79
77
75
73
71
36 40 44 48 52 56 60 64 68 72
10 20 30 40 50 60 70 80 90 100
OUTPUT LOAD (% of Full Load)
INPUT VOLTAGE (V)
Specification for EMC EN55022 Class A Compliance
Specification for EMC EN55022 Class B Compliance
The components used in the figure above are as follows:
The components used in the figure above are as follows:
C1
C2
C3
C1
C2
C3&C4
L1
4.7µF/25V
1210 MLCC
1000pF/2KV
1808 MLCC
1000pF/2KV
1808 MLCC
4.7µF/50V
1812 MLCC
1000pF/2KV PMT-050 (325µH)
1808 MLCC Common Choke
LANC12xxW5
LANC24xxW5
LANC48xxW5
LANC12xxW5
LANC24xxW5
LANC48xxW5
N/A
1000pF/2KV
1808 MLCC
1000pF/2KV
1808 MLCC
6.8µF/50V
1812 MLCC
1000pF/2KV PMT-050 (325µH)
1808 MLCC Common Choke
N/A
N/A
N/A
1000pF/2KV
1808 MLCC
1000pF/2KV
1808 MLCC
2.2µF/100V 2.2µF/100V 1000pF/2KV PMT-050 (325µH)
1812 MLCC 1812 MLCC 1808 MLCC Common Choke
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
7/11/2019
Page 3 of 5
LANCW5 Series
Single and Dual Outputs
2:1 and 4:1 Wide Input Voltage
Up to 6 Watts DC/DC Converters
Rev. E
PMT-050
SPECIFICATIONS
Pins 1-2: 325µH±35% Pins 3-4: 325µH±35%
Test Conditions: 100KHz/100mV
Measurement Instrument: HP 4263B LCR Meter
DCR (Max): 35mΩ
Inductance
Impedance
Measurement Instrument: HIOKI 3540mΩ HITESTER
IDC (Max): 3.3A
Rated Current
Measurement Instrument: Agilent 34401A Meter
ψ0.8mm
Recommended Through Hole
MECHANICAL DRAWING
Unit: inches (mm)
DIP TYPE
SMT TYPE
(add suffix “S”)
Pin size is 0.02 (0.5) Dia or
0.01 x 0.02 (0.25 x 0.50) Rectangular Pin
0.44(11.2)
0.43(10.9)
1.00(25.4)
0.92(23.4)
0.18 (4.6)
24
1
5
23
22
2
3
20
BOTTOM
VIEW
BOTTOM
VIEW
16
13
9
16
15
14
9
10
11
Pin Area
0.04 x 0.02
12
(1.0 x 0.5)
0.15
0.40
0.80(20.3)
0.600 (15.24)
(3.8)
(10.2)
0.80 (20.3)
1. Tolerance: XX.XX ±0.02 (X.X±0.5)
XX.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance: ±0.01 (0.25)
3. Pin dimension tolerance: ±0.004 (0.1)
PIN CONNECTION (DIP)
PIN CONNECTION (SMT)
PIN
2
3
SINGLE
-INPUT
-INPUT
DUAL
-INPUT
-INPUT
PIN
23
22
SINGLE
+INPUT
+INPUT
DUAL
+INPUT
+INPUT
PIN
2
3
SINGLE
-INPUT
-INPUT
DUAL
-INPUT
-INPUT
PIN
23
22
SINGLE
+INPUT
+INPUT
DUAL
+INPUT
+INPUT
9
10
11
NC
COMMON
16
15
14
-OUTPUT
NC (Note 9) NC (Note 9)
+OUTPUT +OUTPUT
COMMON
9
10
11
NC
NC
NC
NC
COMMON
NC
-OUTPUT
NC
16
15
14
-OUTPUT COMMON
NC NC
+OUTPUT +OUTPUT
NC (Note 9) NC (Note 9)
NC -OUTPUT
Others
Others
NC
NC
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
7/11/2019
Page 4 of 5
LANCW5 Series
Single and Dual Outputs
2:1 and 4:1 Wide Input Voltage
Up to 6 Watts DC/DC Converters
Rev. E
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001: 2015
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
(603)778-2300
(888)597-9255
(603)778-9797
E-mail:
Web:
Address:
sales@wallindustries.com
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
©2019 Wall Industries, Inc. Specifications subject to change without notice. Wall Industries is not responsible for typographical errors. The information contained herein is for
informational purposes only. This information is provided by Wall Industries and we make no representations or warranties of any kind, express or implied, about the completeness,
accuracy, reliability, suitability or availability with respect to the information contained in this document for any purpose. All product and manufacturer names are trademarks or
registered trademarks of their respective companies.
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com
7/11/2019
Page 5 of 5
相关型号:
©2020 ICPDF网 联系我们和版权申明