CL60H44-000 [WABASH]

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited; 2级UL5085-3变压器60VA - 75VA ,非固有能源有限公司
CL60H44-000
型号: CL60H44-000
厂家: WABASH TRANSFORMER INC.    WABASH TRANSFORMER INC.
描述:

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
2级UL5085-3变压器60VA - 75VA ,非固有能源有限公司

变压器
文件: 总2页 (文件大小:862K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Class 2 UL5085-3 Transformer  
60VA - 75VA, Non-Inherently Energy Limited  
Series: CL - Lead Wires & Quick-Connects  
Power Rating 60VA to 75VA  
Secondary Fusing Required (Provided by Factory),  
Frequency 50/60Hz  
Insulation Class B (155°C)  
Agency Approvals:  
UL/cUL 5085-3 Class 2 Recognized (File E49606)  
Insulation File No. E95662  
Class 2  
* 60 & 75VA transformers must have overcurrent protectors in series with the secondary winding.  
* Multi voltage combinations are available - consult factory.  
Lead Wires  
Type HX Foot Mount - Steel bracket welded to the  
bottom of the laminations for easy mounting  
Type GX Panel Mount - 0.218” (5.54 mm) diameter  
holes in each corner to allow direct mounting to a panel.  
Quick-Connects  
Type BB Foot Mount, Pri & Sec on Same Side - Quick connect terminals  
with line and load terminations on the same side of transformer.  
Type AE Laydown, Pri & Sec on Top Side - Quick connect terminals  
with line and load terminations on the top of transformer.  
Type AB Foot Mount, Pri & Sec on Opposite Side - Quick connect  
terminals with line and load terminations on opposite sides of transformer  
Terminals:  
Lead Wires: All leads are 18 AWG stranded 2/64” (0.794 mm)  
insulation thickness. Standard parts have 12” (305 mm)  
total length with 1/2” (12.7 mm) strip.  
Standard male quick connects - .250” x .032” (6.35 x .81mm).  
Other available quick connects - .187” x .032” (4.75 x .81 mm)  
Type HX - Foot Mount, Internally Fused  
Type HX - Foot Mount, Integral Circuit Breaker  
Type GX - Panel Mount  
Type BB - Foot Mount, Pri & Sec on Same Side  
Type AE - Laydown, Pri & Sec on Top side, Internally Fused  
Type AE - Laydown Termination, Pri & Sec on Top Side,  
Integral Circuit Breaker  
Dimensions (Inches)  
A
B
Internally Fused  
w/ Integral Circuit Breaker  
Standard Part  
2.500  
2.500  
1.000  
3.300  
1.000  
1.000  
Any application, Any requirement, Contact us for our Custom Designs  
Sales Office:  
300 W Factory Road, Addison IL 60101 Phone: (630) 628-9999 Fax: (630) 628-9922 www.wabashtransformer.com  
20  
Class 2 UL5085-3 Transformer  
60VA - 75VA, Non-Inherently Energy Limited  
Series: CL - Lead Wires & Quick-Connects  
Class 2  
Partial Selection Guide  
Primary  
Voltage  
60 VA  
75 VA  
Size - 1.0” X 1.0”  
Secondary Voltage  
UL  
UL  
Size - 1.0” X 1.0”  
CL60H00-000*  
CL60H00-0CT*  
CL60H01-000*  
CL60H01-0CT*  
CL60H02-000*  
CL60H02-0CT*  
CL60H03-000*  
CL60H03-0CT*  
CL60H04-000*  
CL60H04-0CT*  
24  
24Vct  
24  
CL75J00-000*  
CL75J00-0CT*  
CL75J01-000*  
CL75J01-0CT*  
CL75J02-000*  
CL75J02-0CT*  
CL75J03-000*  
CL75J03-0CT*  
CL75J04-000*  
CL75J04-0CT*  
CL75J05-000*  
CL75J05-0CT*  
CL75J06-000*  
CL75J06-0CT*  
CL75J08-000*  
CL75J08-0CT*  
CL75J09-000*  
CL75J09-0CT*  
CL75J14-000*  
CL75J14-0CT*  
CL75J15-000*  
208/230  
120  
277  
24Vct  
24  
24Vct  
24  
120/208/240  
480  
24Vct  
24  
24Vct  
24  
-
120/208/240/480  
600  
-
24Vct  
24  
-
CL60H06-000*  
CL60H06-0CT*  
CL60H08-000*  
CL60H08-0CT*  
CL60H09-000*  
CL60H09-0CT*  
-
-
-
24Vct  
24  
-
277/380/575  
380  
24Vct  
24  
-
24Vct  
24  
277/380/415/480  
24Vct  
24  
CL60H15-000*  
CL60H50-000*  
CL60H15-0CT*  
CL60H17-000*  
CL60H17-0CT*  
CL60H21-000*  
CL60H21-0CT*  
CL60H30-000*  
CL60H30-0CT*  
CL60H31-000*  
CL60H31-0CT*  
CL60H40-000*  
CL60H40-0CT*  
CL60H41-000*  
CL60H41-0CT*  
CL60H44-000*  
CL60H44-0CT*  
CL60H45-000*  
CL60H45-0CT*  
CL60H48-000*  
CL60H48-0CT*  
CL60H52-000*  
CL60H52-0CT*  
CL60H54-000*  
CL60H54-0CT*  
CL60H60-000*  
CL60H60-0CT*  
-
208/240  
12  
24Vct  
24  
CL75J15-0CT*  
CL75J17-000*  
CL75J17-0CT*  
CL75J21-000*  
CL75J21-0CT*  
CL75J30-000*  
CL75J30-0CT*  
CL75J31-000*  
CL75J31-0CT*  
CL75J40-000*  
CL75J40-0CT*  
CL75J41-000*  
CL75J41-0CT*  
CL75J44-000*  
CL75J44-0CT*  
CL75J45-000*  
CL75J45-0CT*  
CL75J48-000*  
CL75J48-0CT*  
CL75J52-000*  
CL75J52-0CT*  
CL75J54-000*  
CL75J54-0CT*  
CL75J60-000*  
CL75J60-0CT*  
-
-
380/415  
575  
24Vct  
24  
-
24Vct  
24  
480/575  
200/230  
240  
-
24Vct  
24  
24Vct  
24  
24Vct  
24  
120/277  
208/240/480  
208  
24Vct  
24  
24Vct  
24  
24Vct  
24  
-
-
-
-
-
-
100  
24Vct  
24  
265  
24Vct  
24  
24Vct  
24  
208/230/460  
380/460  
24Vct  
* Refer to page number 7. Must complete part number to specify voltages, termination, mounting & fusing.  
For custom designs 3 digit customer ID will be added at the end of the part number.  
Lead Wire Details:  
Primary Voltage  
Color  
COM  
Black  
COM  
Blue  
110,115,120  
White  
12  
200,208,215  
Red  
24  
220, 230, 240  
Orange  
265, 277  
Brown  
380  
Violet  
400, 415  
Red/White  
460, 480  
Grey  
575  
Black/Red  
600  
Black/White  
Secondary Voltage  
Color  
Standard leads: All leads are 12.0” L.O.C (length out of coil) 1/2” strip  
Yellow  
Blue  
Any application, Any requirement, Contact us for our Custom Designs  
Sales Office:  
300 W Factory Road, Addison IL 60101 Phone: (630) 628-9999 Fax: (630) 628-9922 www.wabashtransformer.com  
21  

相关型号:

CL60H44-0CT

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H45-000

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H45-0CT

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H48-000

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H48-0CT

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H50-000

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H52-000

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H52-0CT

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H54-000

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H54-0CT

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H60-000

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH

CL60H60-0CT

Class 2 UL5085-3 Transformer 60VA - 75VA, Non-Inherently Energy Limited
WABASH