SMFA120-S02 [Vitec]
120W Open-Frame Power Supply for Medical Equipment;型号: | SMFA120-S02 |
厂家: | Vitec Power |
描述: | 120W Open-Frame Power Supply for Medical Equipment |
文件: | 总2页 (文件大小:408K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
120W Open-Frame Power Supply for Medical Equipment
SMFA120 SERIES
−
−
−
−
Wide Input Voltage 100 to 240 VAC, 47 to 63Hz
Output Voltage Available From 5VDC~40VDC
Internal EMI filter
Input connector mates with Molex housing 09-50-3051 and Molex 2478 series
crimp terminal
−
Output Connector mates with screw terminal (Terminal Block)(16-22AWG)
or Molex housing 09-50-3121 and Molex 2478 series crimp terminal
Single Output
Size: 3" x 5" x 1.42"
Input Surge Current, Over Voltage and Overload protection
Active Power Factor Correction
−
−
−
−
3 Year Warranty
Approvals:
Single Output
Max. Output Current
Maximum
Output Power
Product Number
Output Voltage
Total Regulation
SMFA120-S02
SMFA120-S03
SMFA120-S04
SMFA120-S05
SMFA120-S06
SMFA120-S07
SMFA120-S08
SMFA120-S09
SMFA120-S10
5 ~ 6 VDC
6 ~ 9 VDC
20.00 ~ 16.66 A
18.33 ~ 12.22 A
13.33 ~ 10.90 A
10.90 ~ 9.23 A
9.23 ~ 7.50 A
7.50 ~ 5.71 A
5.71 ~ 4.44 A
4.44 ~ 3.63 A
3.63 ~ 3.00 A
7%
7%
5%
5%
5%
3%
3%
2%
2%
100W
110W
120W
120W
120W
120W
120W
120W
120W
9 ~ 11 VDC
11 ~ 13 VDC
13 ~ 16 VDC
16 ~ 21 VDC
21 ~ 27 VDC
27 ~ 33 VDC
33 ~ 40 VDC
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Test Conditions
Min.
90
47
Typ.
Max.
260
63
Unit
VAC
Hz
Operating Voltage
Power Factor Correction
Output Power Range
Input Current (Low Line)
Input Current (High Line)
Io=Full load, Vin=90~260VAC
Vin= 90 to 264 VA C
Io=Full load, Vin=115 VAC
Io=Full load, Vin= 230 VAC
Io=Full load, 25°C, Cool start,
Vin=115VAC
0.95
0
0.97
1.00
120
1.7
W
A
A
0.8
Low Line Inrush Current
High Line Inrush Current
48
58
54
63
A
A
Io=Full load, 25°C, Cool start,
Vin=230VAC
Efficiency
Line Regulation
Load Regulation
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC
70
80
0.5
3
88
1
5
%
%
%
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
112
110
132
150
4
%
%
mS
mS
S
%
mA
%/°C
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Io= Full Load, Vin=240VAC/60Hz
All output
16
0.3
Start Up Time
1
0.5
0.095
2
1
0.1
0.04
Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
-0.04
Conditions
Parameter
Operating Temperature
Test Conditions
Min.
0
Typ.
50
Max.
70
Unit
°C
Storage Temperature
-40
85
°C
Relative Humidity
5
95
%
Operating Temperature at 25°C , Calculated per MIL-HDBK-217F
De-rate linearly from 100% load at 50°C to 50% load at 70°C
0.1M
Hrs
Approvals and Compliances
Parameter
Test Conditions
Min.
5656
2828
50
Unit
VDC
VDC
MΩ
CLASS
CLASS
Dielectric Withstanding Voltage for Primary to secondary
Dielectric Withstanding Voltage for Primary to Ground
Isolation Resistance
Primary to secondary
Primary to ground
Test Voltage = 500VDC
Vin=220VAC
EMI requirements for CISPR-11
B
EMI requirements for FCC PART-18
Vin=110VAC
B
Mechanical and PIN out
Note:
PIN CHART
PIN
1.Dimensions are shown in mm.
2.Weight: 420g approx.
3.Input connector mates with Molex housing
1
2
3
4
5
6
7
8
9
10 11 12
MODEL
SMFA120-SXX-12pin OUT OUT OUT OUT OUT OUT RTN RTN RTN RTN RTN RTN
09-50-3051 and Molex 2478 series crimp terminal.
4.Output Connector mates with screw terminal (Terminal
Block)(16-22AWG)or Molex housing 09-50-3121 and Molex
2478 series crimp terminal
PIN
1
2
3
4
5
6
MODEL
SMFA120-SXX-6pin
OUT OUT OUT RTN RTN RTN
相关型号:
©2020 ICPDF网 联系我们和版权申明