300U10 [VISHAY]
Standard Recovery Diodes (Stud Version), 300 A; 标准恢复二极管(梭哈版) , 300安型号: | 300U10 |
厂家: | VISHAY |
描述: | Standard Recovery Diodes (Stud Version), 300 A |
文件: | 总7页 (文件大小:127K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
300U(R) Series
Vishay High Power Products
Standard Recovery Diodes
(Stud Version), 300 A
FEATURES
• Alloy diode
RoHS
• Popular series for rough service
COMPLIANT
• Stud cathode and stud anode version
• RoHS compliant
• Designed and qualified for industrial level
DO-205AB (DO-9)
TYPICAL APPLICATIONS
• Welders
• Power supplies
PRODUCT SUMMARY
• Motor controls
IF(AV)
300 A
• Battery chargers
• General industrial current rectification
MAJOR RATINGS AND CHARACTERISTICS
PARAMETER
TEST CONDITIONS
VALUES
300
UNITS
A
IF(AV)
TC
150
°C
50 Hz
60 Hz
50 Hz
60 Hz
Range
6550
IFSM
A
6850
214
I2t
kA2s
195
VRRM
TJ
100 to 600
- 65 to 200
V
°C
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
V
RRM, MAXIMUM REPETITIVE
VRSM, MAXIMUM NON-REPETITIVE
IRRM MAXIMUM
AT TJ = 175 °C
mA
VOLTAGE
CODE
TYPE NUMBER
PEAK REVERSE VOLTAGE
PEAK REVERSE VOLTAGE
V
V
10
20
30
40
60
100
200
300
400
600
200
300
400
500
700
300U(R)
40
Document Number: 93508
Revision: 24-Jun-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
1
300U(R) Series
Standard Recovery Diodes
(Stud Version), 300 A
Vishay High Power Products
FORWARD CONDUCTION
PARAMETER
SYMBOL
IF(AV)
TEST CONDITIONS
VALUES
300
UNITS
A
Maximum average forward current
at case temperature
180° conduction, half sine wave
130
°C
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
6550
6850
5500
5750
214
No voltage
reapplied
Maximum peak, one cycle forward,
non-repetitive surge current
IFSM
A
100 % VRRM
reapplied
Sinusoidal half wave,
initial TJ = TJ maximum
No voltage
reapplied
195
Maximum I2t for fusing
I2t
kA2s
151
100 % VRRM
reapplied
138
Maximum I2√t for fusing
I2√t
t = 0.1 to 10 ms, no voltage reapplied
2140
0.610
kA2√s
Maximum value of threshold voltage
VF(TO)
V
TJ = 200 °C
Maximum value of forward
slope resistance
rf
0.751
1.40
mΩ
Maximum forward voltage drop
VFM
Ipk = 942 A, TJ = 25 °C
V
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
Maximum junction operating and
storage temperature range
TJ, TStg
- 65 to 200
°C
Maximum thermal resistance,
junction to case
RthJC
DC operation
0.18
0.08
K/W
Maximum thermal resistance,
case to heatsink
RthCS
Mounting surface, smooth, flat and greased
Not lubricated threads
Lubricated threads
37
28
Maximum allowed mounting torque
+ 0 - 20 %
Nm
g
Approximate weight
Case style
250
(JEDEC) see dimensions - link at the end of datasheet
DO-205AB (DO-9) (1)
Note
(1)
302U-A uses case style B-26
ΔRthJC CONDUCTION
CONDUCTION ANGLE
SINUSOIDAL CONDUCTION
RECTANGULAR CONDUCTION
TEST CONDITIONS
UNITS
180°
120°
90°
0.020
0.024
0.031
0.045
0.077
0.015
0.025
0.034
0.047
0.077
TJ = TJ maximum
K/W
60°
30°
Note
• The table above shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
www.vishay.com
2
For technical questions, contact: ind-modules@vishay.com
Document Number: 93508
Revision: 24-Jun-08
300U(R) Series
Standard Recovery Diodes
(Stud Version), 300 A
Vishay High Power Products
200
180
160
140
120
200
300U(R) Series
RthJC (DC) = 0.18 K/W
300U(R) Series
RthJC (DC) = 0.18 K/W
190
180
170
160
150
140
130
120
110
Conduction Angle
Conduction Period
30°
60°
30°
90°
60°
90°
120°
120°
180°
180°
DC
0
50 100 150 200 250 300 350
0
100
Average Forward Current (A)
Fig. 2 - Current Ratings Characteristics
200
300
400
500
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
400
180°
RthSA = 0.1 K/
0.2 K
120°
90°
60°
30°
350
300
250
200
150
100
50
/
W
0.3 K/
W
W
W
0.4 K/
- Delta R
0.5
K/
RMS Limit
W
0.7 K/
W
1 K/
W
Conduction Angle
1.5 K/
W
3 K/
W
300U(R)..D Series
Tj = 200°C
0
0
50 100 150 200 250 300 3
5
0
50 75 100 125 150 175 200
Average Forward Current (A)
Maximum Allowable Ambient Temperature (°C)
Fig. 3 - Forward Power Loss Characteristics
500
450
400
350
300
250
200
150
100
50
RthSA
DC
180°
120°
90°
60°
30°
= 0.1 K/
0.2 K/
W
-
W
Delta
0.3 K/
R
W
0.5 K/
W
RMS Limit
0.7 K/
W
Conduction Period
1
K/
W
1.5
K/
W
3 K/
300U(R) Series
Tj = 200°C
W
0
0
100
200
300
400
5
0
0
50 75 100 125 150 175 200
Average Forward Current (A)
Maximum Allowable Ambient Temperature (°C)
Fig. 4 - Forward Power Loss Characteristics
Document Number: 93508
Revision: 24-Jun-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
3
300U(R) Series
Standard Recovery Diodes
(Stud Version), 300 A
Vishay High Power Products
7000
6000
At Any Rated Load Condition And With
Rated Vrrm Applied Following Surge.
Maximum Non Repetitive Surge Current
Versus Pulse Train Duration.
Initial Tj = 200°C
6500
6000
5500
5000
4500
4000
3500
3000
2500
2000
1500
5500
Initial Tj = 200°C
5000
4500
4000
3500
3000
2500
2000
1500
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
No Voltage Reapplied
Rated Vrrm Reapplied
300U(R) Series
300U(R) Series
0.01
0.1
1
1
10
100
Pulse Train Duration (s)
NumberOfEqualAmplitudeHalfCycleCurrentPulses(N)
Fig. 5 - Maximum Non-Repetitive Surge Current
Fig. 6 - Maximum Non-Repetitive Surge Current
10000
1000
100
Tj = 25°C
Tj = 200°C
300U(R) Series
10
0
0.5
1
1.5
2
2.5
3
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
1
0.1
Steady State Value
RthJC = 0.18 K/W
(DC Operation)
0.01
0.001
300U(R) Series
0.0001
0.001
0.01
0.1
1
10
Square Wave Pulse Duration (s)
Fig. 8 - Thermal Impedance ZthJC Characteristic
www.vishay.com
4
For technical questions, contact: ind-modules@vishay.com
Document Number: 93508
Revision: 24-Jun-08
300U(R) Series
Standard Recovery Diodes
(Stud Version), 300 A
Vishay High Power Products
ORDERING INFORMATION TABLE
Device code
300
U
R
60
A
1
2
3
4
5
-
300 = Standard 300U device
1
302 = 300U top threaded version
2
3
-
-
U = Essential part number
R = Stud reverse polarity (anode to stud)
None = Stud normal polarity (cathode to stud)
Voltage code x 10 = VRRM (see Voltage Ratings table)
-
-
4
5
A = Essential part number
Note: For metric device M16 x 1.5 contact factory
LINKS TO RELATED DOCUMENTS
Dimensions
http://www.vishay.com/doc?95340
Document Number: 93508
Revision: 24-Jun-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
5
Outline Dimensions
Vishay Semiconductors
DO-205AB (DO-9) and B-26 for 300U(R) Series
DIMENSIONS FOR 300U(R)-A SERIES - DO-205AB (DO-9) in millimeters (inches)
19.18 (0.755)
MAX.
11.51 (0.453)
10.74 (0.423)
13.46 (0.530)
11.94 (0.470)
Ø 8.89 (0.350)
Ø 8.38 (0.330)
149.9 (5.90)
134.6 (5.30)
Ø 27.94 (1.10)
MAX.
53.34 (2.10)
MAX.
9.27 (0.365)
7.87 (0.310)
21.03 (0.83)
20.14 (0.79)
31.75 (1.250)
30.94 (1.218)
Across flats
3.18 (0.125)
MAX.
Unthreaded
portion
Ø 19.02 (0.749)
MAX.
3/4"-16UNF-2A
for metric device: M16 x 1.5
contact factory
DIMENSIONS FOR 302U(R)-A SERIES - B-26 in millimeters (inches)
3/8"-24UNF-2A
Ø 9.50 (0.374)
MAX.
16.51 (0.65)
14.99 (0.59)
18.29 (0.72)
16.76 (0.66)
Across flats
Ø 27.94 (1.10)
MAX.
58.67 (2.31)
55.63 (2.19)
28.45 (1.12)
MAX.
9.27 (0.365)
7.87 (0.310)
21.03 (0.828)
20.14 (0.793)
3.18 (0.125)
MAX.
31.75 (1.250) MAX.
Across flats
Ø 19.02 (0.749)
MAX.
3/4"-16UNF-2A
Document Number: 95340
Revision: 24-Jul-08
For technical questions, contact: indmodules@vishay.com
www.vishay.com
1
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Revision: 12-Mar-12
Document Number: 91000
1
相关型号:
©2020 ICPDF网 联系我们和版权申明