288P22494H101 [VISHAY]
Resistor/Capacitor Network, RC NETWORK, ISOLATED, 0.5W, 100ohm, 0.22uF, THROUGH HOLE MOUNT, RECTANGULAR PACKAGE-2, RADIAL LEADED;型号: | 288P22494H101 |
厂家: | VISHAY |
描述: | Resistor/Capacitor Network, RC NETWORK, ISOLATED, 0.5W, 100ohm, 0.22uF, THROUGH HOLE MOUNT, RECTANGULAR PACKAGE-2, RADIAL LEADED 电容器 电阻器网络 电容器网络 |
文件: | 总3页 (文件大小:146K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Type 288P
Vishay Sprague
R-C Arc Suppressors
ORANGE DROP®, Radial Lead
Contact Arc Suppression reduces field maintenance,
premature equipment failure and RFI. A capacitor connected
across the contacts helps in the solution of these problems
but can cause contact welding and reduced equipment
reliability. By adding a resistor in series with the capacitor,
these additional problems are eliminated.
Because of the increased use of R-C combinations for Arc
Suppressors and snubbers, Sprague® provides low cost
Type 288P R-C Arc Suppressors in a single low profile
package.
The standard ratings shown have those combinations of
resistance and capacitance values most commonly required
for low power applications.
The standard Type 288P R-C Arc Suppressors consist of a
metalized polyester film capacitor in series with a low value
1/2 watt composition resistor. These units are supplied with
radial leads for quick and easy installation.
The outer covering is a tough, conformal coating of epoxy
resin for protection against heat and moisture. The Arc
Suppressors are quite similar in appearance to the Type
225P Orange Drop® polyester film capacitors.
Humidity Test: Condition networks with no voltage applied
for 72 hours at 95 % relative humidity and + 75 °C. Remove
networks from humidity chamber, wipe surface dry of
moisture and dry in circulating air for 4 hours. Measure
insulation resistance at + 25 °C and rated DC voltage. The
minimum insulation resistance shall be 5000 Megohm after
test. Not more than one failure in 18 units tested shall be
permitted.
PERFORMANCE CHARACTERISTICS
Operating Temperature: - 40 °C to + 85 °C
Insulation Resistance: When measured at + 25 °C, the
insulation resistance shall exceed 10000 Megohm.
Measurements shall be made after a 2 minute charge at
rated DC voltage.
Tolerance: Standard tolerance is 10 % for both the resistor
and capacitor.
AC Operation: The maximum permissible AC voltage to
which these networks may be exposed is 250 volts rms. In no
case should the sum of the DC and peak AC voltage applied
to a network exceed the rated DC voltage.
DIMENSIONS in inches (millimeters)
T
L
Max.
Max.
H
Max.
R
0.237
[6.020]
Max.
1.125 [28.575]
0.028 [0.711] Dia. (No. 21 AWG)
Min.
Tinned Copper Lead
on Resistor Side.
0.032 [0.813] Dia. (No. 20 AWG)
Tinned Copper-Clad Lead
on Opposite Side
S
0.062 [1.575]
Document Number: 42023
Revision: 09-Feb-06
For technial questions, contact spresale@vishay.com
www.vishay.com
25
Type 288P
Vishay Sprague
STANDARD RATINGS AND DIMENSIONS In inches [millimeters]
L
H
T
CAPACITANCE
(µF)
RESISTANCE*
LEAD
SPACING
(Ω)
PART NUMBER
(Length)
(Height)
(Thickness)
400 VDC
1.000
[25.400]
0.63
[16.00]
0.46
[11.68]
0.691
[17.551]
0.1
0.1
100
470
100
470
47
288P10494J101
288P10494J471
288P22494H101
288P22494H471
288P47494K470
288P47494K101
1.000
[25.400]
0.63
[16.00]
0.46
[11.68]
0.691
[17.551]
1.125
[28.575]
0.59
[14.99]
0.37
[9.40]
0.817
20.752]
0.22
0.22
0.47
0.47
1.125
[28.575]
0.59
[14.99]
0.37
[9.40]
0.817
[20.752]
1.437
[36.500]
0.63
[16.00]
0.41
[10.41]
1.129
[28.677]
1.437
[36.500]
0.63
[16.00]
0.41
[10.41]
1.129
[28.677]
100
* Standard resistor values are 47, 100 and 470 ohms. Other values are available by request.
ORDERING INFORMATION
288P
TYPE
104
CAPACITANCE
9
4
J
101
RESISTANCE
(-XXX)
SPECIAL
CONSTRUCTION
TOLERANCE
DC VOLTAGE
RATING AT + 85 °C
CASE
CODE
Capacitance is expressed
in picofarads. The first two
digits are significant. The
third is the number of
zeros to follow. Values
must conform to decade
rating for the tolerance
specified.
9 = 10 %
This is expressed See Standard This is expressed in A three-digit suffix may
in hundred of volts. Ratings
Example: 288P R5
= 50 volts.
ohms. The first two digits be added by the factory to
are significant. The third denote special
is the number of zeros to construction.
follow.
www.vishay.com
26
For technial questions, contact spresale@vishay.com
Document Number: 42023
Revision: 09-Feb-06
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 11-Mar-11
www.vishay.com
1
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明