V48C5H75BS 概述
CONVERTER MOD DC/DC 5V 75W
V48C5H75BS 数据手册
通过下载V48C5H75BS数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Micro Family
48V Input
Actual size:
2.28 x 1.45 x 0.5in
S
®
[57,9 x 36,8 x 12,7mm]
C
NRTL US
DC-DC Converter Module
Features & Benefits
Applications
Distributed power, medical, ATE, communications, defense and aerospace.
•
•
•
•
•
•
•
•
DC input range: 36 – 75V
Isolated output
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Input surge withstand: 100V for 100ms
DC output: 2 – 48V
Absolute Maximum Ratings
Programmable output: 10 – 110%
Regulation: 0.5% no load to full load
Efficiency: Up to 89%
Parameter
Rating
Unit
VDC
VDC
VDC
VDC
Notes
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to –OUT voltage
–0.5 to +105
–0.5 to +7.0
–0.5 to +7.0
–0.5 to +1.5
Maximum operating temp: 100°C,
full load
•
•
•
•
•
Power density: up to 90W per cubic inch
Height above board: 0.43in [10,9mm]
Parallelable, with N+M fault tolerance
Low-noise ZCS/ZVS architecture
Isolation voltage
IN to OUT
3000
1500
VRMS
VRMS
VRMS
°C
Test voltage
Test voltage
Test voltage
M-Grade
IN to base
OUT to base
500
RoHS Compliant (with F or G pin option)
Operating Temperature
Storage Temperature
–55 to +100
–65 to +125
500 [260]
750 [390]
5 [0.57]
°C
M-Grade
Product Overview
°F [°C]
°F [°C]
<5 sec; wave solder
<7 sec; hand solder
6 each
Pin soldering temperature
Mounting torque
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
.
.
in lbs [N m]
High-frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V48C12T150BL2
V48C
B
Product Grade Temperatures (°C)
Output Power
POUT
50W
Pin Style
Blank: Short
L: Long
Finish
Tin/Lead
Baseplate
Blank: Slotted
2: Threaded
Output Voltage
VOUT
Grade
Operating
Storage
2 = 2V
3V3 = 3.3V
8 = 8V
2V
E
C
=
=
=
=
=
–10 to +100
–20 to +100
–40 to +100
–40 to +100
–55 to +100
–20 to +125
–40 to +125
–40 to +125
–55 to +125
–65 to +125
Tin/Lead
Gold
3: Through-hole
3.3V
5V
75W, 50W
100W, 75W, 50W
100W, 150W
150W, 75W
150W, 75W
150W, 75W
150W, 75W
150W
S: Short ModuMate
N: Long ModuMate
F: Short RoHS
T
Gold
5 = 5V
8V
H
M
Gold
12 = 12V
15 = 15V
24 = 24V
28 = 28V
36 = 36V
48 = 48V
12V
15V
24V
28V
36V
48V
G: Long RoHS
Gold
K: Extra Long RoHS
Gold
150W, 75W
Note: Product images may not highlight current product markings.
48V Micro Family
Page 1 of 13
Rev 9.1
02/2021
48V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
Module Input Specifications
Parameter
Min
Typ
Max
75
Unit
VDC
VDC
VDC
VDC
VDC
mA
Notes
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
36
48
100
35.7
<100ms
34.9
30.5
78.8
29.4
75.7
82.5
2.5
PC pin low
Module Output Specifications
Parameter
Min
Typ
Max
1ꢀ
0.2
Unit
ꢀ
Notes
Output voltage set point
Line regulation
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 – 100ꢀ of full load
0.02
0.002
2
ꢀ
Temperature regulation
Power sharing accuracy
0.005
5
ꢀ / °C
ꢀ
Of nominal output voltage. For trimming below 90ꢀ
of nominal, a minimum load of 10ꢀ of maximum
rated power may be required.
Programming range
10
110
ꢀ
+OUT to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
–0.5 to 3.1
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.1
–0.5 to 62.9
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
8V
12V
15V
24V
28V
36V
48V
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 8.
Thermal Resistance and Capacity
Parameter
Min
Typ
0.24
0.21
10.9
2.8
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
48
48V Micro Family
Page 2 of 13
Rev 9.1
02/2021
48V Input
Module Family Electrical Characteristics (Cont.)
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
Module Control Specifications
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
5.50
1.5
5.75
2.1
6.00
3.0
VDC
mA
PC current = 1.0mA
PC voltage = 5.5V
PC module disable
PC module enable delay
PC module alarm
2.3
2.6
4
2.9
7
VDC
ms
Switch must be able to sink ≥4mA. See Figure 2
0.5
1.1
6.1
VAVG
MΩ
UV, OV, OT, module fault. See Figures 3 and 5
See Figure 3, converter off or fault mode
PR load >30Ω, <30pF
PC resistance
0.9
5.7
150
375
2.4
1.0
5.9
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Volts
mA
500
2.5
625
2.6
12
Ω
25°C
Volts
modules
Minimum pulse width: 20ns
Without PR buffer amplifier
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
1.21
1.23
1000
0.033
1.25
VDC
Ω
Referenced to –Sense
990
1010
SC capacitance
µF
VDC
SC module alarm
0
With open trim; referenced to –Sense. See Figure 7
Module General Specifications
Parameter
Min
Typ
Max
Unit
Notes
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
3000
1500
500
VRMS
VRMS
VRMS
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
Isolation resistance
10
MΩ
IN to OUT, IN to baseplate, OUT to baseplate
1.9
[52.8]
2.1
[59.3]
2.3
[65.8]
ounces
[grams]
Weight (E, C, T grade)
2.1
[58.7]
2.3
[65.2]
2.5
[71.7]
ounces
[grams]
Weight (H, M grade)
Temperature limiting
Agency approvals
100
115
°C
See Figures 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
cURus, cTÜVus, CE
* Isolation test voltage, 1 minute or less.
Note: Specifications are subject to change without notice.
48V Micro Family
Page 3 of 13
Rev 9.1
02/2021
48V Input
Module-Specific Operating Specifications
2VOUT, 50W (e.g. V48C2C50BL)
Parameter
Min
Typ
77.8
85
Max
Unit
ꢀ
Notes
Efficiency
76.5
Nominal input; 75ꢀ load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
106
2.9
4.9
0.2
25
mV
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
2.7
2.8
Volts
Watts
ꢀ
3.3
0.02
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
25.3
17.5
28.8
28.8
35
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
35
3.3VOUT, 75W (e.g. V48C3V3C75BL)
Parameter
Min
Typ
83.7
75
Max
Unit
ꢀ
Notes
Efficiency
82.5
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
94
mV
4.14
4.3
3
4.46
4.5
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
22.7
31.8
31.8
Amps
Amps
Amps
Current limit
22.9
15.9
26.2
26.2
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
3.3VOUT, 50W (e.g.V48C3V3C50BL)
Parameter
Min
Typ
79.6
75
Max
Unit
ꢀ
Notes
Efficiency
78
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
94
4.46
3.7
mV
4.14
4.3
Volts
Watts
ꢀ
2.9
0.02
0.2
No load to full load; nominal input
0
15.15
20.6
20.6
Amps
Amps
Amps
Current limit
15.5
10.6
17.5
17.5
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
5VOUT, 100W (e.g. V48C5C100BL)
Parameter
Min
Typ
85
Max
Unit
ꢀ
Notes
Efficiency
83
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
70
88
6.47
5
mV
6.03
6.25
3.3
Volts
Watts
ꢀ
0.02
0.3
20
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
20.4
14
23
23
26
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
26
5VOUT, 75W (e.g. V48C5C75BL)
Parameter
Min
Typ
83
Max
Unit
ꢀ
Notes
Efficiency
82
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
100
6.25
3
125
6.47
4.5
mV
6.03
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
15
Amps
Amps
Amps
Current limit
15.3
10.5
17.3
17.3
19.5
19.5
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
48V Micro Family
Page 4 of 13
Rev 9.1
02/2021
48V Input
Module-Specific Operating Specifications (Cont.)
5VOUT, 50W (e.g. V48C5C50BL)
Parameter
Min
Typ
84.5
85
Max
Unit
ꢀ
Notes
Efficiency
83.5
Nominal input; 75ꢀ load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
106
6.47
2.4
0.2
10
mV
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
6.03
6.25
1.6
Volts
Watts
ꢀ
0.02
No load to full load; nominal input
0
10.2
7
Amps
Amps
Amps
Current limit
11.5
11.5
13
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
13
8VOUT, 100W (e.g. V48C8C100BL)
Parameter
Min
Typ
87.7
121
9.7
Max
Unit
ꢀ
Notes
Efficiency
86.5
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
152
10.1
4.5
mV
9.36
Volts
Watts
ꢀ
3.6
0.02
0.2
No load to full load; nominal input
0
12.5
16.9
16.9
Amps
Amps
Amps
Current limit
12.7
8.75
14.4
14.4
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
8VOUT, 150W (e.g. V48C8C150BL)
Parameter
Min
Typ
87.8
138
9.7
Max
Unit
ꢀ
Notes
Efficiency
86.5
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
173
10.1
4.6
mV
9.36
Volts
Watts
ꢀ
3.6
0.02
0.2
No load to full load; nominal input
0
18.75
25.4
25.4
Amps
Amps
Amps
Current limit
19.1
13.1
21.6
21.6
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
12VOUT, 150W (e.g. V48C12C150BL)
Parameter
Min
Typ
89.1
170
14.3
3.5
Max
Unit
ꢀ
Notes
Efficiency
88.0
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
212
14.9
5.3
mV
13.7
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
12.5
16.3
16.3
Amps
Amps
Amps
Current limit
12.7
8.75
14.4
14.4
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
12VOUT, 75W (e.g. V48C12C75BL)
Parameter
Min
Typ
88.3
160
14.3
2.6
Max
Unit
ꢀ
Notes
Efficiency
87.0
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
200
14.9
3.8
mV
13.7
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
6.25
8.44
8.44
Amps
Amps
Amps
Current limit
6.37
4.37
7.19
7.19
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
48V Micro Family
Page 5 of 13
Rev 9.1
02/2021
48V Input
Module-Specific Operating Specifications (Cont.)
15VOUT, 150W (e.g. V48C15C150BL)
Parameter
Min
Typ
90.1
120
17.8
4
Max
Unit
ꢀ
Notes
Efficiency
89.0
Nominal input; 75ꢀ load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
150
18.5
6
mV
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
17.1
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
10.2
7
10
Amps
Amps
Amps
Current limit
11.5
11.5
13.5
13.5
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
15VOUT, 75W (e.g. V48C15C75BL)
Parameter
Min
Typ
89.9
80
Max
Unit
ꢀ
Notes
Efficiency
88.5
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
100
18.5
3.9
mV
17.1
17.8
2.6
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
5
Amps
Amps
Amps
Current limit
5.1
3.5
5.75
5.75
6.75
6.75
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
24VOUT, 150W (e.g. V48C24C150BL)
Parameter
Min
Typ
88.5
220
28.1
4.3
Max
Unit
ꢀ
Notes
Efficiency
87.5
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
275
29.1
6.3
mV
27.1
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
6.25
8.13
8.13
Amps
Amps
Amps
Current limit
6.37
4.06
7.19
7.19
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
24VOUT, 75W (e.g. V48C24C75BL)
Parameter
Min
Typ
87.3
48
Max
Unit
ꢀ
Notes
Efficiency
86
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
60
mV
27.1
28.1
3
29.1
3.6
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
3.13
4.23
4.23
Amps
Amps
Amps
Current limit
3.19
0.5
3.6
3.6
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
28VOUT, 150W (e.g. V48C28C150BL)
Parameter
Min
Typ
88.5
110
32.7
3
Max
Unit
ꢀ
Notes
Efficiency
87.5
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
138
33.9
4.5
mV
31.5
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
5.36
6.97
6.97
Amps
Amps
Amps
Current limit
5.46
3.75
6.16
6.16
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
48V Micro Family
Page 6 of 13
Rev 9.1
02/2021
48V Input
Module-Specific Operating Specifications (Cont.)
28VOUT, 75W (e.g. V48C28C75BL)
Parameter
Min
Typ
88.4
200
32.7
4.5
Max
Unit
ꢀ
Notes
Efficiency
87
Nominal input; 75ꢀ load; 25°C
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
250
33.9
6
mV
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
31.5
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
2.67
3.62
3.62
Amps
Amps
Amps
Current limit
2.73
1.87
3.08
3.08
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
36VOUT, 150W (e.g. V48C36C150BL)
Parameter
Min
Typ
87.6
80
Max
Unit
ꢀ
Notes
Efficiency
86.2
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
100
43.4
6.2
mV
40.4
41.9
3.9
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
4.17
5.63
5.63
Amps
Amps
Amps
Current limit
4.25
2.91
4.8
4.8
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
48VOUT, 150W (e.g. V48C48C150BL)
Parameter
Min
Typ
89
Max
Unit
ꢀ
Notes
Efficiency
88
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
92
115
57.7
6.3
mV
53.7
55.7
4.2
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
3.13
4.5
Amps
Amps
Amps
Current limit
3.19
2.19
3.6
3.6
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
4.5
48VOUT, 75W (e.g. V48C48C75BL)
Parameter
Min
Typ
87.9
128
55.7
3.7
Max
Unit
ꢀ
Notes
Efficiency
86.5
Nominal input; 75ꢀ load; 25°C
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, standby
Load regulation
Load current
160
57.7
4.5
mV
53.7
Volts
Watts
ꢀ
0.02
0.2
No load to full load; nominal input
0
1.56
2.11
2.11
Amps
Amps
Amps
Current limit
1.59
1.09
1.79
1.79
Output voltage 95ꢀ of nominal
Output voltage <250mV
Short circuit current
48V Micro Family
Page 7 of 13
Rev 9.1
02/2021
48V Input
Basic Module Operation
C2*
4.7nF
C4*
4.7nF
+IN
PC
PR
+OUT
SC
F1*
C1*
0.2µF
–IN
–OUT
C3*
4.7nF
C5*
4.7nF
For C1 – C5, keep leads and connections short.
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.* See Maxi, Mini, Micro Design Guide.
Output Connections and Considerations
protected for conditions such as lead reversal, noise pickup, open
circuit or excessive output lead resistance between the sense
point and the converters output terminals. For applications that
may draw more than the rated current, a fast acting electronic
circuit breaker must be utilized to protect the converter. Under
no circumstance should the rated current be exceeded. Utilizing
or testing of current limit or short circuit current will damage the
converter. Ensure that the total output capacitance connected to
the converter does not exceed the limits on Page 16, “Maximum
Output Capacitance”, of the design guide.
The permissible load current must never be exceeded during
normal, abnormal or test conditions. Converters subject to dynamic
loading exceeding 25ꢀ of rated current must be reviewed by
Vicor Applications Engineering to ensure that the converter will
operate properly.
Under dynamic-load, light-load or no-load conditions, the converter
may emit audible noise. Converters that utilize remote sense may
require compensation circuitry to offset the phase lag caused
by the external output leads and load impedance. If an external
remote-sense circuit is used, the remote-sense leads must be
Comprehensive Online Application Information
The Design Guide and Applications Manual includes:
• Application circuits
• Design requirements
• EMC considerations
• Current sharing in power arrays
• Thermal performance information
• Recommended soldering methods
• Accessory modules – filtering, rectification, front-ends
• Mounting options
• ...and more.
CLICK HERE TO VIEW
DESIGN GUIDE
Also at vicorpower.com
• PowerBench online configurators
• Over 20 Application Notes
• Online calculators – thermal, trimming, hold-up
• PDF data sheets for ALL Vicor products
48V Micro Family
Page 8 of 13
Rev 9.1
02/2021
48V Input
Primary Control – PC Pin
Module Enable/Disable
Module Alarm
The module may be disabled by pulling PC to 0V (2.3V max) with
respect to the –Input. This may be done with an open collector
transistor, relay, or optocoupler. Converters may be disabled with
a single transistor or relay either directly or via “OR’ing” diodes for
two or more converters. See Figure 2.
The module contains “watchdog” circuitry which monitors input
voltage, operating temperature and internal operating parameters.
In the event that any of these parameters are outside of their
allowable operating range, the module will shut down and PC will
go low. PC will periodically go high and the module will check to
see if the fault (as an example, Input Undervoltage) has cleared.
If the fault has not been cleared, PC will go low again and the
cycle will restart. The SC pin will go low in the event of a fault
and return to its normal state after the fault has been cleared. See
Figures 3 and 5.
Primary Auxiliary Supply
During normal operation only, the PC Pin can source 5.7V
@ 1.5mA. In the example shown in Figure 4, PC powers a
module enabled LED.
Input Undervoltage
Input Overvoltage
Over Temperature
+IN
PC
+IN
+OUT
SC
Module Faults
Auto
Restart
SW1
50Ω
PC
PR
2 – 20ms typ.
f(VIN
)
1kΩ
6kΩ
SW2
SW3
PR
5.7VDC
(0 – 3mA)
Disable
1MΩ
1.23
VDC
–IN
–IN
–OUT
SW1, 2, & 3 shown
in "Fault" position
Disable = PC < 2.3V
Figure 2 — Module enable/disable
Figure 3 — PC/SC module alarm logic
+IN
PC
Fault
400µs typ.
5.7V
PC
4kΩ
"Module
PR
Enabled"
1.23V
2 – 20ms typ.
SC
–IN
Figure 4 — LED on-state indicator
Figure 5 —PC/SC module alarm timing
+IN
+OUT
SC
Comparator
Optocoupler
PC
Alarm
PR
4k
1.00V
–OUT
–IN
Figure 6 —Isolated on-state indicator
Figure 7 — Secondary-side on-state indicator
48V Micro Family
Page 9 of 13
Rev 9.1
02/2021
48V Input
Compatible interface architectures include the following:
Secondary Control – SC Pin
AC-coupled single-wire interface. All PR pins are connected to a
single communication bus through 0.001µF (500V) capacitors. This
interface supports current sharing and is fault tolerant except for
the communication bus. Up to three converters may be paralleled
by this method. See Figure 9.
Output Voltage Programming
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage
DACs. See Figure 8.
Transformer-coupled interface. For paralleling four or more
converters a transformer-coupled interface is required, and under
certain conditions a PR buffer circuit.
+OUT
RU
For details on parallel operation please refer to the
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Trim Up
Error
Load
SC
Amp
RD
1kΩ
0.033μF
Trim Down
–OUT
4.7nF
1.23V
+
–
+IN
PC
PR
–IN
0.2µF
0.001µF
Module 1
Module 2
R1*
1,000VOUT
VNOM – VOUT
RD (Ω) =
RU (Ω) =
4.7nF
4.7nF
Low inductance
ground plane
or bus
1,000 (VOUT – 1.23) VNOM
1.23 (VOUT – VNOM
– 1,000
)
+IN
PC
PR
–IN
0.2µF
0.001µF
R1*
Figure 8 — Output voltage trim-down and trim-up circuit
Trim Down
4.7nF
Parallel
Bus
1. This converter is not a constant-power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated output current.
Figure 9 — AC-coupled single-wire interface
* See Maxi, Mini, Micro Design Guide
2. The trim-down resistor must be connected between the SC
4.7nF
+IN
and –S pins. Do not bypass the SC pin directly with a capacitor.
+
–
0.2µF
R1*
PC
Trim Up
Module 1
T1
PR
1. The converter is rated for a maximum delivered power. To
ensure that maximum rated power is not exceeded, reduce
maximum output current by the same percentage increase in
output voltage.
–IN
4.7nF
4.7nF
+IN
PC
PR
–IN
2. The trim-up resistor must be connected between the SC and
0.2µF
R1*
Module 2
+S pins. Do not bypass the SC pin directly with a capacitor.
T2
3. Do not trim the converter above maximum trim range (typically
+10ꢀ) or the output over voltage protection circuitry may
be activated.
4.7nF
Parallel
Bus
Figure 10 — Transformer-coupled interface
Trim resistor values calculated automatically:
On-line calculators for trim resistor values are available on
the vicor website at:
asp.vicorpower.com/calculators/calculators.asp?calc=1
Resistor values can be calculated for fixed trim up, fixed
trim down and for variable trim up or down.
Number of Converters in Parallel *R1 value Ω
2
75
50
33
3
4
Parallel Bus – PR Pin
5 or more
refer to application note:
Designing High-Power Arrays
using Maxi, Mini, Micro
Family DC-DC Converters
Parallel Operation
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy. Modules of the same input voltage, output
voltage, and power level will current share if all PR pins are
suitably interfaced.
48V Micro Family
Page 10 of 13
Rev 9.1
02/2021
48V Input
Parallel Bus / Voltage-Drop Compensation
• The +OUT and –OUT
power buses should be
designed to minimize
and balance parasitic
impedance from each
module output to the
load.
+OUT
SC
Plane
Module #1
Designated
Parent
+OUT
SC
+S
R7 21.0k
*
C3
*
R4
–OUT
R9*
*
R1
R8
C2
4.02k
R3
0.22µF
U2
R5
U1
*
R2
2.55 k
TLV431
470pF
Vcc
1.00k
R Load
–
–
R11
R6
C1
36.5k
1.65k
+OUT
SC
200mV
+
+
R10
PS2701
U3
1.24k
• At the discretion of the
power system designer,
a subset of all modules
within an array may be
configured as children by
connecting SC
LM10
Gnd
L
O
A
D
Module #2
trimmed
–S
–OUT
down 2%
–OUT
*See Component Selection section below.
• This module is designed for point-of-load regulation, where remote sensing is
not required. Active voltage-drop compensator, as shown here, may be used
in applications with significant distribution losses.
to –OUT.
+OUT
SC
Module #3
trimmed
• Do not use output
OR’ing diodes with
MicroMods.
Ground
Plane
down 4%
Please consult with the Micro Family Isolated Remote Sense Application Note
for additional information.
–OUT
Figure 11 — N+1 module array output connections
Figure 12 — Voltage-drop compensation
Pin Styles*
Designator
Description
Short
Finish
Tin/Lead
Tin/Lead
Gold
Notes
(None)
Requires inboard mounting
L
S
Long
Onboard mounting for 0.065in boards
Short ModuMate
Long ModuMate
Short RoHS
Long RoHS
SurfMate or inboard socket mounting
N
F
Gold
Onboard socket mounting
Gold
Select for RoHS-compliant inboard solder, socket or SurfMate mounting
Select for RoHS-compliant onboard solder or socket mounting
G
K
Gold
Extra Long RoHS
Gold
Select for RoHS compliance onboard mounting for thicker PCBs
(not intended for socket or Surfmate mounting)
* Pin style designator follows the “B” after the output power and precedes the baseplate designator.
Ex. V48C12T150BN2 — Long ModuMate Pins
Storage
Vicor products, when not installed in customer units, should be
stored in ESD safe packaging in accordance with ANSI/ESD S20.20,
“Protection of Electrical and Electronic Parts, Assemblies and
Equipment” and should be maintained in a temperature controlled
factory/ warehouse environment not exposed to outside elements
controlled between the temperature ranges of 15°C and 38°C.
Humidity shall not be condensing, no minimum humidity when
stored in an ESD compliant package.
48V Micro Family
Page 11 of 13
Rev 9.1
02/2021
48V Input
Mechanical Drawings
Converter Pins
No. Function Label
Ref Dwg. 37207 rev 5
1
+IN
+
Primary
Control
2
PC
3
4
5
Parallel
–IN
PR
–
–OUT
–
Secondary
Control
6
7
SC
+
+OUT
SLOTTED BASEPLATE
2. DIMENSIONS AND VALUES IN BRACKETS ARE METRIC
3. MANUFACTURING CONTROL IS IN PLACE TO ENSURE THAT THE SPACING
BETWEEN THE MODULES LABEL SURFACE TO THE PRINTED CIRCUIT BOARD
OF THE APPLICATION RANGES FROM DIRECT CONTACT (ZERO), TO THE
MAXIMUM GAP AS CALCULATED FROM THE TOLERANCE STACK-UP
AND IS NOT SUBJECT NEGATIVE TOLERANCE ACCUMULATION
Figure 13 — Module outline
ALL MARKINGS
THIS SURFACE
0.062 0.010
1,57 0,25
PCB THICKNESS
0.800*
20,32
INBOARD
SOLDER
MOUNT
ONBOARD
SOLDER
MOUNT
0.525*
13,34
PLATED
THRU HOLE
DIA
0.275*
6,99
SHORT PIN STYLE
0.094 0.003
LONG PIN STYLE
ALUMINUM
BASEPLATE
0.094 0.003
(7X)
0.145*
3,68
2,39 0,08
2,39 0,08
PINS STYLES
0.133
3,38
SOLDER:TIN/LEAD PLATED
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
1
7
2
3
4
5
1.734**
44,04
2.000*
50,80
For Soldering Methods and Procedures
Please refer to:
The Maxi, Mini, Micro Design Guide.
6
Unless otherwise specified,
dimensions are in inches
mm
0.06
1,5
R
(4X)
0.53
13,5
0.45
11,5
.400*
10,16
0.003
*DENOTES TOL =
Decimals
Tol.
Angles
0,08
1.090**
27,69
0.XX
0.01
0.25
**PCB WINDOW
1°
0.XXX
0.005
0.127
Figure 14 — PCB mounting specifications
48V Micro Family
Page 12 of 13
Rev 9.1
02/2021
48V Input
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/dc-dc-converters-board-mount/high-density-dc-dc-converters for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property
rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Contact Us: http://www.vicorpower.com/contact-us
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
www.vicorpower.com
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
©2019 – 2021 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.
All other trademarks, product names, logos and brands are property of their respective owners.
48V Micro Family
Page 13 of 13
Rev 9.1
02/2021
V48C5H75BS 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
V48C5H75BS2 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, PACKAGE-7 | 获取价格 | |
V48C5H75BS3 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 75W, Hybrid, PACKAGE-7 | 获取价格 | |
V48C5M100AL | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid | 获取价格 | |
V48C5M100AN | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid | 获取价格 | |
V48C5M100AS2 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid | 获取价格 | |
V48C5M100B | VICOR | 48Vin / 5Vout / 100Watts DC-DC Converter Module | 获取价格 | |
V48C5M100B2 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-7 | 获取价格 | |
V48C5M100B3 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-7 | 获取价格 | |
V48C5M100BF | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-7 | 获取价格 | |
V48C5M100BF2 | VICOR | DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, PACKAGE-7 | 获取价格 |
V48C5H75BS 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6