V28A5T175S3 [VICOR]
DC-DC Regulated Power Supply Module, 1 Output, 175W, Hybrid, MODULE-9;型号: | V28A5T175S3 |
厂家: | VICOR CORPORATION |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 175W, Hybrid, MODULE-9 |
文件: | 总11页 (文件大小:753K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Maxi Family
28 V Wide Input
Actual size:
S
4.6 x 2.2 x 0.5 in
117 x 56 x 12,7 mm
®
C
NRTL US
C
US
DC-DC Converter Module
Absolute Maximum Ratings
Features
• DC input range: 9 – 36 V*
• Isolated output
Parameter
Rating
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Notes
• Input surge withstand: 50 V for 100 ms
• DC output: 3.3 – 48 V
• Programmable output: 10 to 110%
• Regulation: 0.2% no load to full load
• Efficiency: Up to 85%
+In to –In voltage
PC to –In voltage
PR to –In voltage
SC to -Out voltage
-Sense to -Out voltage
-0.5 to +53
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
1.0
•
Maximum operating temp: 100°C
• Powerdensity:upto40Wpercubicinch
• Height above board: 0.43 in. (10,9 mm)
• Parallelable, with N+M fault tolerance
• Low noise ZCS/ZVS architecture
See Module Output
Specifications
+Out to -Out, +Sense to -Out
Isolation voltage
in to out
3000
1500
Vrms
Vrms
Test voltage
Test voltage
Test voltage
M-Grade
• RoHS Compliant (with F or G pin option)
in to base
Product Overview
out to base
500
Vrms
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost effec-
tiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and high
efficiency.
Operating Temperature
Storage Temperature
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
°C
°C
M-Grade
°F (°C)
°F (°C)
in-lbs (N-m)
<5 sec; wave solder
<7 sec; hand solder
6 each
Pin soldering temperature
Mounting torque
Applications
Industrial and process control, distributed power,
medical, ATE, communications, defense,
aerospace.
*10-36 V DC input range for 3.3, 6.5, 8, 36
and 48 V outputs. All others derate power
to 75% for Vin 9 – 10 V.
For details on proper operation please refer to the
Design Guide & Applications Manual for Maxi,
Mini, Micro Family.
Part Numbering
e.g. V28A12T200BL2
V28A
B
Output Power
Output Voltage
Baseplate
Blank: Slotted
2: Threaded
Pin Style
Finish
Product Grade Temperatures (°C)
Vout
3.3 V
5 V
Pout
Grade
Operating
Storage
40 to +125
40 to +125
55 to +125
65 to +125
Blank: Short
Tin/Lead
3 V 3 = 3.3 V
5 = 5 V
6.5 = 6.5 V
8 = 8 V
12 = 12 V
15 = 15 V
24 = 24 V
28 = 28 V
36 = 36 V
48 = 48 V
150 W
175 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
200 W
C
T
H
M
=
=
=
=
-
-
-
-
20 to +100
40 to +100
40 to +100
55 to +100
-
-
-
-
L: Long
Tin/Lead
3: Through-hole
6.5 V
8 V
S: Short ModuMate Gold
N: Long ModuMate
F: Short RoHS
Gold
Gold
Gold
12 V
15 V
24 V
28 V
36 V
48 V
G: Long RoHS
Maxi Family
Page 1 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
MODULE FAMILY ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
36
Unit
Vdc
Vdc
Notes
Operating input voltage
Input surge withstand
9
28
50
<100 ms
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
8.75
8.1
8.9
8.4
Vdc
Vdc
Vdc
mA
7.8
36.3
37.8
12
39.6
14
PC pin low
MODULE OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
1%
Unit
Vout nom
%
Notes
Output voltage set point
Line regulation
Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
0.02
0.002
2
0.20
0.005
5
Temperature regulation
Power sharing accuracy
% / °C
%
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Programming range
10
110
%
+Out to -Out, +Sense to -Out – Absolute Maximum Ratings
3.3 V
5 V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 9.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.2
-0.5 to 62.9
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
6.5 V
8 V
12 V
15 V
24 V
28 V
36 V
48 V
THERMAL RESISTANCE AND CAPACITY
Parameter
Min
Typ
0.08
0.07
4.9
Max
Unit
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
°C / Watt
°C /Watt
°C /Watt
°C /Watt
Watt-sec/°C
Baseplate to ambient; 1000 LFM
Thermal capacity
1.1
165
Maxi Family
Page 2 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
MODULE CONTROL SPECIFICATIONS
Parameter Min
PRIMARY SIDE (PC = Primary Control; PR = Parallel)
Typ
Max
Unit
Notes
PC bias voltage
current limit
5.50
1.5
5.75
2.1
6.00
3.0
Vdc
mA
PC current = 1.0 mA
PC voltage = 5.5 V
During normal operation
PC module disable
PC module enable delay
PC module alarm
2.3
2.6
4
2.9
7
Vdc
ms
Switch must be able to sink ≥4 mA. See Fig. 2
0.5
1.1
6.1
Vavg
MΩ
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30 Ω, <30 pF
PC resistance
0.9
5.7
1.0
5.9
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Volts
mA
150
375
2.4
500
2.5
625
2.6
12
Ω
25°C
Volts
modules
Minimum pulse width: 20 ns
Without PR buffer amplifier
SECONDARY SIDE (SC = Secondary Control)
SC bandgap voltage
1.21
1.23
1000
0.033
1.25
Vdc
Ω
Referenced to –Sense
SC resistance
990
1010
SC capacitance
µF
SC module alarm
0
Vdc
With open trim; referenced to –Sense. See Fig. 7
MODULE GENERAL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Remote sense (total drop)
0.5
Vdc
0.25 V per leg (sense leads must be connected to
respective, output terminals)
Isolation test voltage (in to out)*
Isolation test voltage (in to base)*
Isolation test voltage (out to base)*
3000
1500
500
Vrms
Vrms
Vrms
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
Isolation resistance
10
MΩ
in to out, in to baseplate, out to baseplate
6.5
(184.3)
7.3
(207.5)
8.1
(230.7)
ounces
(grams)
Weight (E, C, T grade)
7.4
(209.3)
8.2
(232.5)
9.0
(255.7)
ounces
(grams)
Weight (H, M grade)
Temperature limiting
Agency approvals
100
115
°C
See Figs. 3 and 5. Do not operate coverter >100C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
cURus, cTÜVus, CE
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
Maxi Family
Page 3 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3 Vout, 150 W (e.g. V28A3V3C150BL)
Parameter
Efficiency
Min
77.3
Typ
78.6
80
4.30
11.4
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
Ripple and noise
Output OVP set point
Dissipation, stand-by
Load regulation
Load Current
100
4.46
12.7
0.2
45.45
61.5
61.5
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
4.14
No load to full load; nominal input
0
46.4
31.8
Current limit
Short circuit current
52.3
52.3
Output voltage 95% of nominal
Output voltage <250 mV
5 Vout, 175 W (e.g. V28A5C175BL)
Parameter
Efficiency
Min
75.7
Typ
76.8
280
6.25
14.4
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, stand-by
Load regulation
Load Curent
350
6.47
15.5
0.2
35
49.0
47.3
6.03
No load to full load; nominal input
0
35.7
24.5
Current limit
Short circuit current
40.3
40.3
Output voltage 95% of nominal
Output voltage <250 mV
6.5 Vout, 200 W (e.g. V28A6V5C200BL)
Parameter
Efficiency
Min
76.8
Typ
78.8
275
7.98
11.6
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
344
8.26
12.2
0.2
30.77
41.6
41.6
7.7
No load to full load; nominal input
0
31.4
21.5
35.4
35.4
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
8 Vout, 200 W (e.g. V28A8C200BL)
Parameter
Efficiency
Min
79.5
Typ
80.9
325
9.7
15.6
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
407
10.1
16.5
0.2
25
33.8
33.8
9.36
No load to full load; nominal input
0
25.5
17.5
28.8
28.8
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
12 Vout, 200 W (e.g. V28A12C200BL)
Parameter
Efficiency
Min
81.0
Typ
83.0
280
14.3
11.0
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, stand-by
Load regulation
Load Current
350
14.9
12.2
0.2
16.67
22.6
22.6
13.7
No load to full load; nominal input
0
17.0
11.6
Current limit
Short circuit current
19.2
19.2
Output voltage 95% of nominal
Output voltage < 250mV
Maxi Family
Page 4 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
15 Vout, 200 W (e.g. V28A15C200BL)
Parameter
Efficiency
Min
82.2
Typ
84.5
220
17.8
12.7
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
Ripple and noise
Output OVP set point
Dissipation, stand-by
Load regulation
Load Current
275
18.5
13.7
0.2
13.33
20.6
20.6
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
17.1
No load to full load; nominal input
0
13.5
9.31
Current limit
Short circuit current
15.3
15.3
Output voltage 95% of nominal
Output voltage <250 mV
24 Vout, 200 W (e.g. V28A24C200BL)
Parameter
Efficiency
Min
82.8
Typ
86.0
315
28.1
12.3
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, stand-by
Load regulation
Load Current
394
29.1
13.5
0.2
8.33
11.3
11.3
27.1
No load to full load; nominal input
0
8.49
5.83
Current limit
Short circuit current
9.6
9.6
Output voltage 95% of nominal
Output voltage <250 mV
28 Vout, 200 W (e.g. V28A28C200BL)
Parameter
Efficiency
Min
83.5
Typ
85.0
200
32.7
15.5
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, stand-by
Load regulation
Load Current
250
33.9
18.0
0.2
7.14
10.0
10.0
31.5
No load to full load; nominal input
0
7.28
4.99
Current limit
Short circuit current
8.2
8.2
Output voltage 95% of nominal
Output voltage <250 mV
36 Vout, 200 W (e.g. V28A36C200BL)
Parameter
Efficiency
Min
80.9
Typ
82.6
225
41.9
14.4
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, stand-by
Load regulation
Load Current
282
43.4
16.8
0.2
5.56
8.06
7.5
40.4
No load to full load; nominal input
0
5.67
3.89
Current limit
Short circuit current
7.7
6.9
Output voltage 95% of nominal
Output voltage <250 mV
48 Vout, 200 W (e.g. V28A48C200BL)
Parameter
Efficiency
Min
81.8
Typ
82.6
360
55.7
15.6
0.02
Max
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
Ripple and noise
Output OVP set point
Dissipation, stand-by
Load regulation
Load Current
450
57.7
18.3
0.2
4.17
5.84
5.43
53.7
No load to full load; nominal input
0
4.25
2.92
Current limit
Short circuit current
4.4
4.8
Output voltage 95% of nominal
Output voltage <250 mV
Maxi Family
Page 5 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
BASIC MODULE OPERATION
C2*
4.7nF
C4*
4.7nF
+IN
PC
PR
+OUT
+S
F1*
SC
C1*
0.2µF
–S
–IN
–OUT
C3*
4.7nF
C5*
4.7nF
For C1 – C5, keep leads and connections short.
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.
* See Maxi, Mini, Micro Design Guide.
Comprehensive Online Application Information
The Design Guide and Applications Manual includes:
• Application circuits
• Design requirements
• EMC considerations
• Current sharing in power arrays
• Thermal performance information
• Recommended soldering methods
• Accessory modules – filtering, rectification, front-ends
• Mounting options
...and more.
CLICKꢀHERE TOꢀVIEW
DESIGN GUIDE
Also at vicorpower.com
• PowerBench online configurators
• Over 20 Application Notes
• Online calculators – thermal, trimming, hold-up
• PDF data sheets for ALL Vicor products
Maxi Family
Page 6 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
PRIMARY CONTROL - PC PIN
Module Enable / Disable
Module Alarm
The module may be disabled by pulling PC below 2.3 V with
respect to the –Input. This may be done with an open collector
transistor, relay, or optocoupler. Multiple converters may be
disabled with a single transistor or relay either directly or via
“OR’ing” diodes. See Figure 2.
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will
shut down and PC will go low. PC will periodically go high
and the module will check to see if the fault (as an example,
overtemperature) has cleared. If the fault has not been cleared,
PC will go low again and the cycle will restart. The SC pin
will go low in the event of a fault and return to its normal
state after the fault has been cleared. See Figures 3 and 5.
Primary Auxiliary Supply
At 5.7 V, PC can source up to 1.5 mA. In the example shown
in Figure 4, PC powers a module enabled LED.
Input Undervoltage
+IN
PC
Input Overvoltage (See Note 1)
+OUT
+IN
PC
Overtemperature
Module Faults
Auto
Restart
SW1
+S
SC
–S
2-20 ms typ.
50 Ω
f (V
)
IN
SW1, 2, & 3
shown in
1 K
6 K
SW2
SW3
1 M
PR
"Fault" position
PR
Disable
5.7 Vdc
–IN
(0-3 mA)
1.23
Vdc
– OUT
–IN
1
Disable = PC <2.3 V
Not applicable for 300 Vdc input family
Figure 2 — Module enable / disable.
Figure 3 — PC/SC module alarm logic.
+IN
PC
Fault
PC
40 μs typ.
5.7 V
4 kΩ
"Module
Enabled"
PR
1.23 V
2–20 ms typ.
SC
–IN
Figure 4 — LED on-state indicator.
Figure 5 — PC/SC module alarm timing.
+IN
PC
Optocoupler
+OUT
Comparator
+S
SC
–S
4 kΩ
Alarm
PR
1.00V
–IN
–OUT
Figure 6 — Isolated on-state indicator.
Figure 7 — Secondary side on-state indicator.
Maxi Family
Page 7 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
SECONDARY CONTROL - SC PIN
PARALLEL BUS - PR PIN
Output Voltage Programming
Parallel Operation
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage
DACs. See Figure 8.
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy. Modules of the same input voltage, output
voltage, and power level will current share if all PR pins are
suitably interfaced.
Compatible interface architectures include the following:
+OUT
+S
AC coupled single-wire interface. All PR pins are connected
to a single communication bus through 0.001 µF (500 V)
capacitors. This interface supports current sharing and is fault
tolerant except for the communication bus. Up to three
converters may be paralleled by this method. See Figure 9.
Error Amplifier
Ru
Trim Up
–
SC
+
Load
1 kΩ
Transformer coupled interface. For paralleling four or more
converters a transformer coupled interface is required. See
Figure 10.
Rd
Trim Down
0.033 uF
-S
1.23 V
100 Ω typ.
For details on parallel operation please refer to the
–OUT
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
1,000 Vout
Vnom – Vout
Rd (ohms) =
RU (ohms) =
4.7 nF
+
–
+IN
PC
PR
–IN
1,000 (Vout –1.23) Vnom
1.23 (Vout – Vnom)
– 1,000
0.2 µF
Z1*
Module 1
Module 2
0.001 µF
Figure 8 — Output voltage trim down and trim up circuit.
4.7 nF
4.7 nF
0.2 µF
Low inductance
ground plane
or bus
Trim Down
1. This converter is not a constant power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated output current.
+IN
PC
PR
–IN
0.001 µF
Z1*
2. The trim down resistor must be connected between the SC
and -S pins. Do not bypass the SC pin directly with a
capacitor.
4.7 nF
Parallel
Bus
Figure 9 — AC coupled single-wire interface.
* See Maxi, Mini, Micro Design Guide.
Trim Up
1. The converter is rated for a maximum delivered power. To
ensure that maximum rated power is not exceeded, reduce
maximum output current by the same percentage increase in
output voltage.
4.7 nF
+
–
+IN
PC
PR
–IN
0.2 µF
Z1*
2. The trim up resistor must be connected between the SC
and +S pins. Do not bypass the SC pin directly with a
capacitor.
Module 1
Module 2
T1
4.7 nF
4.7 nF
3. Do not trim the converter above maximum trim range
(typically +10%) or the output over voltage protection
circuitry may be activated.
+IN
PC
PR
–IN
0.2 µF
Z1*
T2
Trim resistor values calculated automatically:
On-line calculators for trim resistor values are available on the
vicor website at:
asp.vicorpower.com/calculators/calculators.asp?calc=1
Resistor values can be calculated for fixed trim up, fixed trim
down and for variable trim up or down.
4.7 nF
Parallel
Bus
Figure 10 — Transformer-coupled interface.
Maxi Family
Page 8 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
PARALLEL BUS OUTPUT
•
•
The +Out and –Out power buses should be designed to
minimize and balance parasitic impedance from each
module output to the load.
+OUT
+S
The +Sense pins must be tied together to form a
+Sense bus. This must be Kelvin connected to +Out
at a single point. The –Sense pins should be tied
together to form a –Sense bus. This must be Kelvin
connected to –Out at a single point.
SC
Module 1
–S
–OUT
+S
–S
•
•
•
At the discretion of the power system designer,
a subset of all modules within an array may be
configured as slaves by connecting SC to –S.
+OUT
+S
Load
Module 2
SC
OR’ing diodes may be inserted in series with the
+Out pins of each module to provide module
output fault tolerance.
–S
–OUT
The +Sense and -Sense leads should be routed in close
proximity to each other on the printed circuit board. If
wires are used to connect the converters on a PCB to
an external load, the Sense leads should be twisted
together to reduce noise pickup.
+OUT
+S
SC
Module N+1
–S
–OUT
Figure 11 — N+1 module array output connections.
PINꢀSTYLES*
Designator
Description
Short
Finish
Notes
(None)
Tin/Lead
Tin/Lead
Gold
Requires in-board, mounting
L
S
N
F
Long
On-board mounting for 0.065" boards
Short ModuMate
Long ModuMate
Short RoHS
Long RoHS
SurfMate or in-board socket mounting
Gold
On-board socket mounting
Gold
Select for RoHS compliant in-board solder, socket, or SurfMate mounting
Select for RoHS compliant on-board solder or socket mounting
G
Gold
*
Pin style designator follows the “B” after the output power and precedes the baseplate designator.
Ex. V48A12T500BN2 — Long ModuMate Pins
Maxi Family
Page 9 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
MECHANICAL DRAWINGS
Converter Pins
No. Function Label
1
+In
+
Primary
Control
2
PC
3
4
5
6
Parallel
–In
PR
–
–Out
–
–Sense
–S
Secondary
Control
7
SC
8
9
+Sense
+Out
+S
+
Figure 12 — Module outline
ALL MARKINGS
THIS SURFACE
ONBOARD
SOLDER
MOUNT
INBOARD
SOLDER
MOUNT
LONG PIN STYLE
SHORT PIN STYLE
0.062 0.010
PCB THICKNESS
0.094 0.003
2,39 0,08
0.094 0.003
2,39 0,08
(7X)
(2X)
1,57 0,25
PLATED
THRU HOLE
DIA
0.194 0.003
4,93 0,08
0.194 0.003
4,93 0,08
1.790**
45,47
0.06
R
(4X)
0.178
4,52
1,5
1
2
3
4
ALUMINUM
BASEPLATE
PINS STYLES
SOLDER:TIN/LEAD PLATED
4.200*
106,68
3.844**
97,64
MODUMATE: GOLD PLATED COPPER
RoHS: GOLD PLATED COPPER
FOR SOLDERING METHODS AND PROCEDURES
PLEASE REFER TO THE MAXI, MINI, MICRO
DESIGN GUIDE.
9
8
7
6
5
Unless otherwise specified,
dimensions are in inches
mm
0.400*
10,16
0.45
11,5
0.53
13,5
Decimals
Tol.
Angles
0.700*
17,78
1.000*
25,40
1.400*
35,56
0.XX
0.01
0,25
0.005
0,127
0.003
0,08
* DENOTES TOL =
**PCB WINDOW
1°
0.XXX
0.195
4,95
Figure 13 — PCB mounting specifications
Maxi Family
Page 10 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
28 V Input
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are
used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH
RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat-
ing safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the prod-
ucts described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Maxi Family
Page 11 of 11
Rev 2.3
vicorpower.com
800 735.6200
2/2013
相关型号:
V28A6.5C200BG
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-9
VICOR
V28A6.5C200BG2
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-9
VICOR
V28A6.5C200BG3
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-9
VICOR
V28A6.5H200G
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-9
VICOR
V28A6.5H200G3
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-9
VICOR
V28A6.5M200BF3
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-9
VICOR
V28A6.5M200F2
DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-9
VICOR