USER GUIDE | UG:003  
PRM® and VTM® Customer Evaluation Boards  
The Customer Evaluation Boards described in this document are intended to acquaint you with the  
benefits and features of a Factorized Power Architecture (FPATM). They are not designed to be installed  
in end-use equipment.  
Contents  
Page  
1
Introduction  
Please read this document before setting up a Customer Evaluation  
Board.  
Board Overview  
2
3
During operation, the power devices and surrounding structures can be operated safely at high temperatures.  
Recommended  
Hardware  
• Remove power and use caution when connecting and disconnecting test probes and interface  
lines to avoid inadvertent short circuits and contact with hot surfaces.  
• When testing electronic products always use approved safety glasses. Follow good laboratory  
practice and procedures.  
Initial Set Up  
4
4
Baseline Test  
Procedure  
Introduction  
A Factorized Power Architecture offers a fundamentally new and improved approach to distributed  
power. Factorizing DC-DC power conversion into its basic functions – isolation and transformation on the  
one hand and output voltage control and regulation on the other – and arranging those functions in a  
sequence maximizes power system performance and cost effectiveness. VTM modules put isolated current  
multiplication and voltage division directly at the Point of Load (POL), and an upstream PRM  
non-isolated regulator controls the Factorized Bus voltage supplied to the VTM to provide line and load  
regulation. With this architecture, the Factorized Bus voltage can be relatively high; distribution losses can  
be minimized with narrower copper traces; and the PRM may be located at any convenient location, either  
adjacent to or remote from the VTM. PRMs operate from a wide variety of input sources to drive VTMs.  
VTMs are extremely fast and quiet and provide voltage division ratios as high as 32. VTMs enable the user  
to efficiently supply up to 100 A from each full VI Chip package at regulated output voltages as low as 0.8  
Vdc or higher, as needed.  
VTM-CB  
7
8
The DC-DC  
Converter Chip Set  
Ordering  
Information  
9
With FPA, only a VTM is needed at the POL. VTMs, unimpeded by serial inductance, feature very high  
bandwidth and extremely fast transient response, allowing energy to be stored efficiently at the relatively  
high Factorized Bus voltage. Without bulk capacitors at the POL, precious board real estate may be  
reclaimed for essential functions. The density, efficiency, performance, cost-effectiveness, and architectural  
superiority of FPA make it the least intrusive form of distributed power and facilitate the development of  
more advanced, competitive products.  
The PRM may be used as a standalone non-isolated regulation stage, whereas the VTM is intended to be  
used with a PRM. For customers to evaluate these components, special Customer Boards are available. To  
obtain one of these boards, simply append the chosen PRM or VTM part number with "-CB".  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 1  
Please take a closer look at the PRM-CB board.  
Figure 1 is a picture of a PRM-AL mounted to the PRM-CB board.  
The board has several features that enable the user to fully explore the capabilities of the PRM-AL:  
2
4
3
5
6
Figure 1  
PRM-AL mounted  
to PRM-CB board  
7
1
8
9
Board Overview (reference the designators in the image above)  
1
Source voltage input points are designed to accommodate #10 hardware and Panduit ring lugs.  
BE CERTAIN THAT THE POLARITY IS CORRECT BEFORE APPLYING POWER.  
2
3
4
Auxiliary control (H01) - access points for PR, IL, TM, PC, and VH, (header shown installed).  
Reference test point Signal Ground (SG).  
Adjustment potentiometers for indicated function are used in conjunction with actuation of  
corresponding switch in Item 5.  
5
PRM port connections (switch bank and silk screen reference).  
a. Toggling the switch indicated PC to the ON position inhibits the PRM output.  
b. Toggling the switch indicated IL to the ON position enables an adjustable current limit effected  
by varying the corresponding IL trim pot (Item 4).  
c. Toggling the switch indicated SC to the ON position enables adjustment of the output voltage  
down from the set point determined by the OS resistor by varying the corresponding SC trim  
pot (Item 4). - CAUTION: depending upon the initial output voltage set point determined by  
the OS resistor it is possible to trim the SC so low that the output shuts off. The minimum  
output voltage per the data sheet is 26 Vdc.  
d. Toggling the switch indicated CD to the ON position places the PRM in Adaptive Loop  
regulation mode (for use with the VTM-CB) from the Local Loop regulation mode. (In Local  
Loop mode the set voltage is regulated at the output terminals of the PRM.) Adjusting the  
corresponding CD trim pot (Item 4) changes the gain of the loop to compensate for different  
OS settings and/or interconnect resistive losses.  
e. Toggling the switch indicated OSV (OS Variable) to the ON position requires the switch  
indicated OSF (OS Fixed) be placed in the OFF position and allows the PRM output set point to  
be varied within the range specified on the data sheet.  
f. Toggling the switch indicated OSF to the ON position sets the output of the PRM to the  
nominal value indicated on the data sheet. If this switch is in the OFF position and the OSV  
switch is also OFF, the unit will not function.  
g. IT IS BEST TO SET THE SWITCH POSITION AND CORRESPONDING TRIM POT SETTINGS  
BEFORE APPLYING POWER TO THE BOARD.  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 2  
6
7
8
Test point for Secondary Control (SC)  
Output voltage points are designed to accommodate #10 hardware and Panduit ring lugs.  
Output connector (J01) for mating with VTM-CB providing Vout and VC. As shown on the  
schematic (Figure 2) there are four pins dedicated to the + Out, four for the -Out, and two for the  
VC. Each contact is rated for 3 A. The excess capacity afforded by these pins can facilitate  
testing multiple VTM-CBs from a single PRM-CB using an appropriate wiring harness and mating  
connector. This may also be achieved using the large pads of Item 7.  
9
Output scope jack (J02). Headers H01 and J01 are 0.100" spacing, 10 position female,  
manufactured by Sullins Electronics and available from Digi-Key as part # S5519-ND.  
Below is the schematic for this PCB. Double clicking the image will launch Adobe Acrobat to  
allow you a better view.  
Figure 2  
PRM-CB schematic diagram  
Recommended Hardware  
QTY  
4
Description  
ring lug  
Manufacturer P/N  
Panduit LCAS6-10-L  
Kit # 26647 contains:  
4 #10-32 screw  
4 #10 flat washer  
4 #10 lock washer  
4 #10 hex nut  
All hardware is stainless steel except the ring lug.  
Kit # 26647 is included with the Customer Evaluation Board.  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 3  
Initial Set Up  
To test the PRM® mounted to the board it is necessary to configure the switch bank (Item 5) as shown  
on the silk screen in Figure 3. Placing the switch bank in this state connects a fixed resistor between  
OS and SG of the PRM that sets the output voltage of the PRM to the nominal value indicated on its  
respective data sheet.  
Failure to configure the switch bank in this state prior to testing may result in improper  
output or no output.  
Baseline Test Procedure - PRM-CB (Refer to Figure 3)  
1.0 Recommended Equipment  
1.1  
1.2  
1.3  
1.4  
1.5  
1.6  
1.7  
DC power supply – 0-100 V; 500 W.  
DC electronic load – pulse capable; 0-100 V; 100 A minimum.  
DMM.  
Oscilloscope.  
Appropriately sized interconnect cables.  
Fastening hardware.  
Fan (if the PRM is to be operated for extended periods of time or at an elevated  
ambient temperature we recommend the supplied heat sink be installed).  
Safety glasses.  
1.8  
1.9  
Data sheet for the requisite PRM.  
Figure 3  
PRM Customer Board Layout  
switch bank  
(Item 5)  
switch reference  
(silk screen)  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 4  
2.0 Hook Up  
2.1  
Connect the power supply +Out lead to the +In terminal of the Customer  
Evaluation Board.  
2.2  
Connect the power supply –Out lead to the –In terminal of the Customer  
Evaluation Board.  
2.3  
2.4  
A high quality, low-noise power supply should be connected to these locations  
Connect a lead between the +Out of the Customer Evaluation Board and +In  
of the load.  
2.5  
2.6  
Connect a lead between the –Out of the Customer Evaluation Board and –In  
of the load.  
Connections to these locations should be with short heavy gauge leads.  
3.0 Verify Connections  
4.0 Test Sequence  
4.1  
4.2  
4.3  
4.4  
4.5  
Have the latest version of the PRM® data sheet in hand.  
Assure that the DC supply is set to 0 Vdc prior to turning the unit on.  
Confirm that the switch bank is configured as shown in the silk screen on the board.  
Turn on the DC supply.  
Make sure the DC load is set to constant current and at 0 A prior to turning  
on the load.  
4.6  
4.7  
Turn on the DC load.  
Connect an oscilloscope to the test point provided to monitor output voltage. Many  
types of scope probes may be directly connected to these points if the probe is  
equipped with a removable plastic sheath. Be careful to avoid creating ground loops  
when making measurements of this voltage and the input voltage. It is recommended  
that the measurements be made separately. Shorting the -input and -output of the PRM  
will defeat the PRM current limit feature as the current shunt is in this path.  
Turn on a fan if desired.  
4.8  
4.9  
4.10  
Raise the DC input voltage to the nominal value indicated on the data sheet.  
Verify no load operation by raising and lowering the input voltage through the entire  
input voltage range. The output voltage should remain constant within the tolerance  
indicated in the data sheet.  
4.11  
4.12  
Re-establish the nominal input voltage.  
Slowly increase the load current to full load while monitoring the output voltage. The  
output voltage should remain within the limits specified in the appropriate PRM data  
sheet.  
4.13  
4.14  
Return the load current to 0 A and decrease the input voltage to low line.  
Repeat step 4.12. Depending upon the supply used and the source impedance it may  
be necessary to adjust the input voltage to keep the input to the PRM at low line.  
Return the load current to 0 A and increase the input voltage to high line.  
Repeat step 4.12.  
4.15  
4.16  
5.0 You have now verified the functionality of the PRM over the entire line and load  
operating range.  
6.0 Deviating from Nominal Settings  
This board has provisions, as described in the Board Overview section, to adjust the  
configuration of the PRM about the nominal values. The data sheet for the PRM has equations  
and curves for determining the required resistor values needed for specific conditions.  
Applications requiring output voltages other than the nominal setting will need to have the  
new value set via the trim pots and respective switches. Reference Items 4 and 5 of the Board  
Overview and the schematic shown in Figure 2.  
6.1  
Adjust the PRM Output Voltage Set Point  
6.1.1 Make sure that the power is removed from the unit prior to making adjustment.  
6.1.2 Using a DMM (set to measure resistance), probe between SG (Item 3) and the pad  
labeled OS located next to the 5 ktrim pot R08.  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 5  
6.1.3 Adjust R08 such that the meter reads ~ 200 . This value added to the fixed resistor  
R07 should total ~ 2.3 k. Note: R07 is 1.7 kon the boards with the  
MIL-COTS PRM.  
6.1.4 One could also probe between SG and the ON side of switch OSV (#5) and set the  
total resistance shown to ~ 2.3 k.  
6.1.5 Move switch OSF (#6) to the OFF position.  
6.1.6 Move switch OSV (#5) to the ON position.  
6.1.7 The unit is now ready to provide the desired output voltage set point.  
6.1.8 Powering the device on should yield a no-load output voltage of the nominal specified  
value.  
6.1.9 The output voltage can now be set to the desired value by varying trim pot OS (R08).  
6.1.10 IT MAY BE POSSIBLE TO INADVERTENTLY TRIM THE OUTPUT TOO HIGH ENABLING  
THE OVERVOLTAGE PROTECTION CIRCUIT. If this happens, reduce the impedance of  
R08. The initial conditions of steps 6.1.2 and 6.1.3 can be used to recover.  
6.1.11 The desired output voltage set point can also be achieved by using the equations in  
the data sheet and setting the total OS resistance (R07+R08) to that value and then  
configuring the switches as above.  
6.1.12 Be certain to adhere to the power vs. output voltage curve in the data sheet to avoid  
over powering the device!  
6.2 Adjusting the Current Limit  
6.2.1 Increasing the load beyond the rated maximum may activate the PRMs internal  
current limit (see data sheet for values) feature. Certain applications may require a  
lower limit and for those situations we offer the adjustment feature.  
6.2.2 Refer to the data sheet for the resistance vs. limit curve for the desired limit value.  
Note: the IL values of resistors installed on this board (R01+R02: 2 k+100 k) may  
not cover the entire range of the curve.  
6.2.3 The adjustable IL mode is engaged by repositioning the IL switch (#2) from OFF to ON.  
(This may be done while the unit is powered.)  
6.2.4 Adjusting the IL trim pot will reduce the current limit from the factory preset limits  
specified in the data sheet. It is not possible to increase this limit beyond the factory  
settings.  
6.2.5 To reinstate the factory limit return the IL switch to the OFF position.  
6.3 Trimming the output voltage using SC  
6.3.1 Once the output voltage has been determined and set using the OS resistors, it is still  
possible to trim the output down to 26 V using the SC control. Adjusting the output  
in this manner rather than merely adjusting the output via the OS values provides  
improved regulation.  
6.3.2 Depending upon the chosen initial output voltage determined by the OS resistors, the  
amount of available adjustment might be very limited. Enabling SC adjustment by  
toggling the SC switch (#3) to the ON position may result in shut down.  
6.3.3 To avoid the situation described in 6.3.2, set the SC trim pot R04 (100 k) to its  
maximum value prior to enabling the switch.  
6.3.4 The data sheet has an equation for calculating the appropriate resistor value for a  
trimmed output voltage. This value would be the sum of fixed resistor R03 (5.11 k)  
and the trim pot R04. R04 can be set using the test points provided locally, or the  
sum set using the SC and SG test points (Items 3 and 6) when the SC switch is ON.  
6.4  
Activating Adaptive Loop Regulation and Interconnect Compensation CD.  
6.4.1 The CD switch (#4) and the associated fixed resistor R05 (20 ) and trim pot R06  
(20 ) enable the PRM Adaptive Loop regulation feature, which compensates for  
the VTM output resistance induced voltage drop as the load current from the VTM is  
increased.  
6.4.2 This feature is intended to be used with mating VTM-CB discussed in detail in the  
next section.  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 6  
VTM-CB (Figure 4)  
The VTM® module provides the isolation stage and the output voltage step down. When paired with  
the PRM the chip set forms a traditional DC-DC converter. The -CB board for the VTM is intended to  
be used in conjunction with the PRM-CB; nevertheless, in order to test this standalone, it is possible to  
inject a VC pulse as specified in the data sheet to the exposed lead from the header corresponding to  
the VC pin. Refer to the board schematic Figure 5 for the appropriate pin(s.) An impedance  
measurement may prove just as expeditious.  
3
Figure 4  
VTM-CB  
5
1
2
4
3
Board Overview  
1
Source voltage input points (Item 1) are designed to accommodate #10 hardware and Panduit ring  
lugs. BE CERTAIN POLARITY IS CORRECT BEFORE APPLYING POWER.  
2
Input connector J01 (Item 2) mates with PRM-CB providing Vin and VC. As can be seen from the  
following schematic there are four pins dedicated to the + In, four for the -In, and two for the  
VC. Each contact is rated for 3 A. The excess capacity afforded by these pins can facilitate testing  
multiple VTM-CBs from a single PRM-CB using an appropriate wiring harness and mating  
connector. This may also be achieved using the large pads of Item 1.  
Note: There is a removable male to male insert installed into this connector. This allows the  
mate to be either gender which may be important depending upon the availability of connectors.  
The Kelvin connection points for Vin and Vout (Item 3) are for use in efficiency measurements.  
The scope jack (Item 4) is used to view output voltage parameters.  
3
4
5
Output voltage points (Item 5) are designed to accommodate #10 hardware and Panduit  
ring lugs.  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 7  
Figure 5 is the schematic for this PCB. Double clicking the image will launch Adobe Acrobat to allow  
you a better view.  
Figure 5  
VTM-CB schematic diagram  
The DC-DC Converter Chip Set  
The -CB boards in Figure 6 allow the user to select and configure the PRM® and VTM® to the unique  
application requirements of their system. By selecting the PRM to accept the desired input voltage,  
one need only select the VTM to provide the desired output voltage and plug them together if the  
nominal voltages are all that are required.  
Figure 6  
CB boards  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 8  
For example, if a P048F048T24AL-CB and a V048F120T025-CB are mated as above, the input range  
to the pair is 36 – 75 Vdc and the output would be 12 Vdc at no load decreasing by Iout x Rout of  
the VTM® as the load current increases. This Vout decrease is due to the switch bank being configured  
as shown in the silk screen. In this configuration, the PRM® is set for Local Loop mode as described in  
Section 5d.  
To provide for load regulation at the output of the VTM, the Adaptive Loop regulation mode should  
be engaged. To activate this feature of the PRM-AL, the switch indicated CD (switch #4) should be set  
to the ON position. The corresponding trim pot should be set to 19.2 which will result in a total CD  
to SG resistance of 39.2 . This is the optimal value for the nominal PRM output voltage as set by the  
fixed OS resistor installed on the board and activated by the OSF (switch #6) in the ON position. Be  
certain to refer to the data sheets for the appropriate resistor values for your requirements.  
To validate the functionality of the Adaptive Loop regulation, repeat the steps of 2.0 to 5.0 under the  
section Baseline Test Procedure - PRM-CB except in this instance the output connections are to be  
made to the VTM-CB output terminals. Both the PRM and VTM data sheets should be in hand. The  
load current refers to the VTM output current ratings. Be certain to make the connections to the  
supply and load prior to mating the boards to avoid stressing the connectors.  
The PRM Adaptive Loop regulates the output of the VTM without sense lines. The Factorized Bus  
voltage (Vf) may be moniored by using J02 on the PRM-CB board (Item 9) while increasing the load  
current. Observe the Vf voltage increases with the load current, compensating for the insertion loss  
due to the VTM output resistance.  
VTM output voltages, which deviate from the nominal configuration, are available by changing the  
output set point of the PRM as described in section 6 of this document and using the formula  
described in the data sheet.  
Ordering Information  
The PRM and VTM Customer Evaluation Boards are specified by add the suffix “-CB” to the  
appropriate PRM or VTM model number.  
Go to http://www.vicorpower.com/contact-us for ordering information.  
12/2013  
vicorpower.com  
Applications Engineering: 800 927.9474  
Rev 1.1  
Page 9  

相关型号:

MV036F120M010_10

Transformer
VICOR

MV036F180M007

VTM Current Multiplier
VICOR

MV036F180M007-CB

VTM CURRENT MULTIPLIER EVAL BOAR
VICOR

MV036F180M007A

暂无描述
VICOR

MV036F240M005

VTM Current Multiplier
VICOR

MV036F240M005-CB

VTM CURRENT MULTIPLIER EVAL BOAR
VICOR

MV036F360M003

VTM Current Multiplier
VICOR

MV036F360M003-CB

VTM CURRENT MULTIPLIER EVAL BOAR
VICOR

MV036F360M003A

Analog Circuit, 1 Func, Hybrid, SMD-60
VICOR

MV036T015M080

Analog Circuit, 1 Func, Hybrid
VICOR

MV036T022M055

Analog Circuit, 1 Func, Hybrid
VICOR

MV036T030M040

Analog Circuit, 1 Func, Hybrid
VICOR