IB054E120T32P100
更新时间:2024-09-18 22:02:20
品牌:VICOR
描述:4:1 Intermediate Bus Converter Module: Up to 300 W Output
IB054E120T32P100 概述
4:1 Intermediate Bus Converter Module: Up to 300 W Output
IB054E120T32P100 数据手册
通过下载IB054E120T32P100数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载IBC Module
IB0xxE120T32xx-xx
S
®
C
NRTL US
C
US
4:1 Intermediate Bus Converter Module: Up to 300 W Output
Features
• Input: 36 – 60 Vdc
• 97.9% peak efficiency
(38 – 55 Vdc for IB048x)
• Low profile: 0.38” height above board
• Industry standard 1/8 Brick pinout
• Sine Amplitude Converter
• Output: 12.0 Vdc at 48 Vin
• Output current up to 32 A
• Output power: up to 300 W [A]
Size:
2.30 x 0.9 x 0.38 in
58,4 x 22,9 x 9,5 mm
• Low noise 1 MHz ZVS/ZCS
• 2,250 Vdc isolation
(1,500 Vdc isolation for IB048x)
[A] For higher power applications see 500 W module IB0xxE120T40xx-xx.
Applications
Product Overview
• Enterprise networks
The Intermediate Bus Converter (IBC) Module is a very efficient, low profile, isolated, fixed
ratio converter for power system applications in enterprise and optical access networks.
Rated at up to 300 W from 38 to 55 Vin, the IBC conforms to an industry standard
eighth brick footprint while supplying the power of a quarter brick. Its leading
efficiency enables full load operation at 65°C with only 200 LFM airflow. Its small cross
section facilitates unimpeded airflow — above and below its thin body — to minimize
the temperature rise of downstream components.
• Optical access networks
• Storage networks
• Automated test equipment
PART NUMBER DESIGNATION
Input
Voltage
Output Voltage
(Nom.) x 10
Output
Current
Enable
Logic
Pin
Length
Function
Package
Temperature Grade
Options
I
B
0
x
x
E
1
2
0
T
3
2
x
x
-
x
x
N = Negative
P = Positive
00 = Open frame
T = -40°C ≤ TOPERATING ≤ +100°C
-40°C ≤ TSTORAGE ≤ +125°C
IB = Intermediate
E = Eighth Brick
Bus Converter
Format
1 = 0.145 in
2 = 0.210 in
3 = 0.180 in
048 = 38 - 55 Vdc
050 = 36 - 60 Vdc
054 = 36 - 60 Vdc*
32 = Max Rated Output Current
120 = (VOUT nominal @ VIN = 48 Vdc) X 10
(4:1 transfer ratio)
*w/operating transient to 75 Vdc
IBC MODULE
Page 1 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS
All specifications valid at 48 VIN , 100% rated load and 25°C ambient, unless otherwise indicated.
Absolute Maximum Ratings
Min
Max
Unit
Notes
See Input Range Specific
Characteristics for details
Input voltage (+In to –In)
–0.5
75
Vdc
Input voltage rate
EN –IN
5
20
V/µs
Vdc
Vdc
A
-0.5
-0.5
Output voltage (+Out to –Out)
Output current
See note
32
See OVP setpoint max
Pout ≤ 300 W
Dielectric withstand
(input to output)
2,250
(1,500 for IB048x)
Vdc
1 min.
Temperature
Operating junction
Storage
-40
-55
125
125
°C
°C
Hottest Semiconductor
Electrical Characteristics
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
INPUT RANGE SPECIFIC CHARACTERISTICS
IB048E120T32xx-xx
Operating input voltage
38
48
55
75
5
Vdc
Vdc
V/µs
Non-operating input surge withstand
<100 ms
Operating input dv/dt
Undervoltage protection
Turn-on
0.003
33
31
2
38
36
Vdc
Vdc
Vdc
µs
Turn-off
Turn-on/Turn-off hysteresis
Time constant
7
Undervoltage blanking time
UV blanking time is enabled after start up
50
100
200
µs
Overvoltage protection
Turn-off
60
55
64
64
Vdc
Vdc
µs
Turn-on
Time constant
4
Peak short circuit input current
DC Output voltage band
Output OVP set point
Dielectric withstand
Insulation resistance
30
A
No load, over Vin range
Module will shut down
9.5
16.2
1,500
12.0
30
13.75
Vdc
Vdc
Vdc
MΩ
Input to output. All units are tested in production.
Input to output
IBC MODULE
Page 2 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
All specifications valid at 48 VIN , 100% rated load and 25°C ambient, unless otherwise indicated.
(Continued)
Electrical Characteristics
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
INPUT RANGE SPECIFIC CHARACTERISTICS CONT.
IB050E120T32xx-xx
Operating input voltage
36
48
60
75
5
Vdc
Vdc
V/µs
Non-operating input surge withstand
<100 ms
Operating input dv/dt
Undervoltage protection
Turn-on
0.003
31
29
2
36
34
Vdc
Vdc
Vdc
µs
Turn-off
Turn-on/Turn-off hysteresis
Time constant
7
Undervoltage blanking time
UV blanking time is enabled after start up
50
100
200
µs
Overvoltage protection
Turn-off
65
60
69
69
4
Vdc
Vdc
µs
Turn-on
Time constant
Peak short circuit input current
DC Output voltage band
Output OVP set point
Dielectric withstand
Insulation resistance
40
15
A
No load, over Vin range
9
12
30
48
Vdc
Vdc
Vdc
MΩ
Module will shut down
16.2
2,250
Input to output. All units are tested in production.
Input to output
IB054E120T32xx-xx
Operating input voltage
Operating input surge withstand
36
60
75
5
Vdc
Vdc
V/µs
<100 ms
Operating input dv/dt
Undervoltage protection
Turn-on
0.003
31
29
2
36
34
Vdc
Vdc
Vdc
µs
Turn-off
Turn-on/Turn-off hysteresis
Time constant
7
Undervoltage blanking time
UV blanking time is enabled after start up
50
100
200
µs
Overvoltage protection
Turn-off
76
75
79.5
78
4
Vdc
Vdc
µs
Turn-on
Time constant
Peak short circuit input current
DC Output voltage band
Output OVP set point
Dielectric withstand
Insulation resistance
30
15
A
No load, over Vin range
9
12
30
Vdc
Vdc
Vdc
MΩ
Module will shut down
16.2
2,250
Input to output. All units are tested in production.
Input to output
COMMON INPUT SPECIFICATIONS
Turn ON delay
Start up inhibit
VIN reaching turn-on voltage
to enable function operational, see Figure 6
20
25
30
50
ms
µs
Enable to 10% VOUT; pre-applied VIN,
see Figure 7, 0 load capacitance
Turn-on delay
IBC MODULE
Page 3 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
SPECIFICATIONS (CONT.)
All specifications valid at 48 VIN , 100% rated load and 25°C ambient, unless otherwise indicated.
(Continued)
Electrical Characteristics
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
COMMON INPUT SPECIFICATIONS CONT.
From 10% to 90% VOUT, 10% load,
0 load capacitance. See Figure 8
Output voltage rise time
Restart turn-on delay
50
µs
See page 12 for restart after EN pin disable
250
ms
No Load power dissipation
Enabled
3.0
0.17
3.9
0.24
8.2
18
W
W
A
Disabled
Input current
Low line, full load
Inrush current overshoot
Using test circuit in Figure 21, 15% load, high line
At max power;
A
Input reflected ripple current
400
25
mArms
Using test circuit in Figure 22. See Figure 5
Repetitive short circuit peak current
Internal input capacitance
A
8.8
5
µF
nH
Internal input inductance
Recommended external
input capacitance
200 nH maximum source inductance
47
0
470
µF
OUTPUT
Output power [a]
Output current
300
32
W
A
P ≤ 300 W
Output start up load
of Iout max, maximum output capacitance
15
%
Effective output resistance
Line regulation (K factor)
5.2
mΩ
VOUT = K • VIN @ no load
0.247
0.250
0.253
10
Full power operation; See Parallel Operation
on page 13; up to 3 units
Current share accuracy
%
Efficiency
50% load
See Figure 1
See Figure 1
97.0
97.4
97.4
97.9
1.6
%
%
nH
µF
µF
Full load
Internal output inductance
Internal output capacitance
Load capacitance
55
0
3000
150
20 MHz bandwidth (Figure 16),
using test circuit in Figure 23
Output voltage ripple
60
mVp-p
Of Iout max., will not shutdown when started
into max Cout; and 15% load
Output Overload protection threshold
105
150
%
Auto restart with duty cycle <10%
Over current protection time constant
Short circuit current response time
Switching frequency
1.2
1.5
ms
µs
1.0
1
MHz
Dyanmic response - Load
Vo overshoot/undershoot
Vo response time
Load change: +/- 25% of IOUT Max,
Slew rate (di/dt) = 1 A/µs.
100
mV
µs
See Figures: 11-14
Dyanmic response - Line
Line step of 5 V in 1 µs, within VIN operating
range. (CIN = 500 uF, CO = 350 uF)
(Figure 15 illustrates similar converter response
when subjected to a more severe line transient.)
Vo overshoot
1.25
V
[a]
Does not exceed IPC-9592 derating guidelines. At 70°C ambient, full power operation may exceed IPC-9592 guidelines, but does not exceed
component ratings, does not activate OTP and does not compromise reliability.
IBC MODULE
Page 4 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
(Continued)
Electrical Characteristics
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
OUTPUT CONT.
Unit will start up into a pre-bias
voltage on the output.
Pre-bias voltage
0
15
Vdc
Control & Interface Specifications
Attribute
Symbol
Conditions / Notes
Referenced to –IN
VEN = 0.8 V
Min
Typ
Max
Unit
Enable (negative logic)
Module enable threshold
Module enable current
Module disable threshold
Module disable current
Disable hysteresis
0.8
Vdc
µA
130
200
2.4
Vdc
µA
VEN = 2.4 V
130
500
2.5
mV
Vdc
Enable pin open circuit voltage
3.0
EN to –IN resistance
Enable (positive logic)
Open circuit, 10 V applied between EN and -IN
Referenced to –IN
35
kΩ
Module enable threshold
Module disable threshold
EN source current (operating)
EN voltage (operating)
2.0
4.7
2.5
3.0
1.45
2
Vdc
Vdc
mA
Vdc
VEN = 5 V
5
5.3
Conditions: 25°C case, 75% rated load and specified input voltage range unless otherwise specified.
General Characteristics
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
MTBF
Calculated per Telcordia SR-332, 40°C
Calculated at 30°C
1.0
7
Mhrs
Years
Service life
TJ; Converter will reset when over
temperature condition is removed
Over temperature shut down
125
130
30
135
°C
Dielectric withstand
Insulation resistance
Mechanical
Input to output
Input to output
1,500
Vdc
MΩ
Weight
0.71 / 20.3
2.30 /58.4
0.9/22.9
oz/g
Length
in/mm
in/mm
in/mm
Years
Width
Height above customer board
Pin Solderability
Moisture Sensitivity Level
Clearance to customer board
0.38/9.5
Storage life for normal solderability
Not applicable, for wave soldering only
From lowest component on IBC
UL/CSA 60950-1
1
MSL
N/A
0.12/0.30
in/mm
cURus
Agency approvals
UL/CSA 60950-1, EN60950-1
cTUVus
Derate operating temp 1°C
per 1,000 feet above sea level
Altitude, operating
-500
10
10,000
90
Feet
%
Relative humidity, Operating
RoHS compliance
Non condensing
Compatible with RoHS directive 2002/95/EC
IBC MODULE
Page 5 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
IPC-9592A, Based on Class II Category 2 the following detail is applicable. – Pre-conditioning required
Environmental Qualification
Test Description
Test Detail
Quantity Tested
Low Temp
High Temp
3
3
3
3
3
3
3
Rapid Thermal Cycling
6 DOF Random Vibration Test
Input Voltage Test
5.2.3 HALT (Highly Accelerated Life testing)
Output Load Test
Combined Stresses Test
5.2.4 THB (Temp. Humidity Bias)
(72 hr presoak required) 1000 hrs – Continuous Bias
30
Power cycle - On 42 minutes
Off 1 minute, On 1 minute, Off 1 minute, On 1 minute, Off 1 minute,
On 1 minute, Off 1 minute, On 1 minute, Off 10 minutes. Alternating
between maximum and minimum operating Voltage every hour.
30
5.2.5 HTOB (High Temp. Operating Bias)
5.2.6 TC (Temp. Cycling)
5.2.7 Power Cycling
700 cycles , 30 minute dwell at each extreme – 20C minimum ramp rate.
Reference IPC-9592A
30
3
Random Vibration – Operating IEC 60068-2-64 (normal operation vibration)
Random Vibration Non-operating (transportation) IEC 60068-2-64
Shock Operating - normal operation shock IEC 60068-2-27
Free fall - IEC 60068-2-32
3
3
5.2.8 – 5.2.13 Shock and Vibration
5.2.14 Other Environmental Tests
3
3
Drop Test 1 full shipping container (box)
12
5.2.14.1 Corrosion Resistance – Not required
N/A
3
5.2.14.2 Dust Resistance – Unpotted class II GR-1274-CORE
5.2.14.3 SMT Attachment Reliability IPC-9701 - J-STD-002
5.2.14.4 Through Hole solderability – J-STD-002
3
5
ESD Classification Testing
Sample size assumes CDM testing
12
Total Quantity (est.)
161
IBC MODULE
Page 6 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
WAVEFORMS
Efficiency TAMB 25°C
Efficiency TAMB 55°C
99%
98%
97%
96%
95%
94%
93%
92%
99%
98%
97%
96%
95%
94%
93%
92%
0
6
:
13
19
26
32
0
6
13
19
26
32
Iout (A)
48 V
Iout (A)
48 V
VIN
38 V
55 V
VIN
:
38 V
55 V
Figure 1 — Efficiency vs. output current, 25°C ambient
Figure 2 — Efficiency vs. output current, 55°C ambient
Efficiency TAMB 70°C
99%
98%
97%
96%
95%
94%
93%
92%
0
6
13
19
26
32
Iout (A)
VIN
:
38 V
48 V
55 V
Figure 3 — Efficiency vs. output current, 70°C ambient
Figure 4 — Inrush current at high line 15% load
Figure 5 — Input reflected ripple current at nominal line, full load
Figure 6 — Turn on delay time;
VIN turn on delay at nominal line, 15% load
IBC MODULE
Page 7 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
WAVEFORMS (CONT.)
Figure 7 — Turn on delay time;
Figure 8 — Output voltage rise time at nominal line, 10% load
Enable turn on delay at nominal line, 15% load
Figure 9 — Overshoot at turn on at nominal line, 15% load
Figure 10 — Undershoot at turn off at nominal line, 10% load
Figure 11 — Load transient response; nominal line
Figure 12 — Load transient response; Full load to 75%; nominal line
Load step 75–100%
IBC MODULE
Page 8 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
WAVEFORMS (CONT.)
Figure 13 — Load transient response; nominal line
Figure 14 — Load transient response; 25–0%; nominal line
Load step 0–25%; 5 A/div
Figure 16 — Output ripple; Nominal line, full load
Figure 15 — Input transient response;
Vin step low line to high line at full load
Figure 17 — Two modules parallel array test. VOUT and IIN change when
Figure 18 — Two modules parallel array test. VOUT and IIN change when
one module is disabled. Nominal VIN, IOUT = 32A
one module is enabled. Nominal VIN, IOUT = 32A
IBC MODULE
Page 9 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
WAVEFORMS (CONT.)
Output Current Derating
Output Current Derating
35
30
25
20
15
10
5
35
30
25
20
15
10
5
0
0
25
35
45
Ambient Temperature (°C)
200 LFM 400 LFM
55
65
75
85
95
25
35
45
Ambient Temperature (°C)
200 LFM 400 LFM
55
65
75
85
95
600 LFM
600 LFM
Figure 19 — Maximum output current derating vs ambient air
temperature. Transverse airflow, Board and junction
temperatures within IPC-9592 derating guidelines
Figure 20 — Maximum output current derating vs ambient air
temperature. Longitudinal airflow, Board and junction
temperatures within IPC-9592 derating guidelines
Current Probe
Current Probe
10 µH
+IN
EN
+OUT
–OUT
+
_
+IN
EN
+OUT
–OUT
+
_
IBC
V
source
C*
IBC
47 µF
V
source
470 µF
–IN
–IN
*Maximum load capacitance
Figure 21 — Inrush current overshoot
Figure 22 — Input reflected ripple current
0.1 µF
10 µF
+IN
–IN
+OUT
–OUT
IBC
E – Load
Cya
Cyc
Cyd
Cyb
20 MHz BW
Cya-d = 4700 pF
Figure 23 — Test circuit; output voltage ripple
IBC MODULE
Page 10 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
THERMAL DATA
Figure 24 — Thermal plot, 200 LFM, 25°C, 48 Vin, 300 W output power
Figure 25 — Thermal plot, 200 LFM, 25°C, 48 Vin, 300 W output power
Figure 26 — Thermal plot, 400 LFM, 25°C, 48 Vin, 300 W output power
Figure 27 — Thermal plot, 400 LFM, 25°C, 48 Vin, 300 W output power
Figure 28 — Thermal plot, 600 LFM, 25°C, 48 Vin, 300 W output power
Figure 29 — Thermal plot, 600 LFM, 25°C, 48 Vin, 300 W output power
IBC MODULE
Page 11 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
PIN / CONTROL FUNCTIONS
+In / -In – DC Voltage Input Pins
The IBC input voltage range should not be exceeded. An internal
undervoltage/overvoltage lockout function prevents operation outside of
the normal operating input range. The IBC turns on within an input voltage
window bounded by the “Input under-voltage turn-on” and “Input
over-voltage turn-off” levels, as specified. The IBC may be protected against
accidental application of a reverse input voltage by the addition of a
rectifier in series with the positive input, or a reverse rectifier in shunt with
the positive input located on the load side of the input fuse.
1
2
3
5
4
Top View
The connection of the IBC to its power source should be implemented with
minimal distribution inductance. If the interconnect inductance exceeds
100 nH, the input should be bypassed with a RC damper to retain low
source impedance and stable operation. With an interconnect inductance
of 200 nH, the RC damper may be 47 µF in series with 0.3 Ω. A single
electrolytic or equivalent low-Q capacitor may be used in place of the series
RC bypass.
Pin
1
2
Function
Vin+
Enable
Vin-
3
4
5
Vout-
Vout+
EN - Enable/Disable
Negative Logic Option
If the EN port is left floating, the IBC output is disabled. Once this port is-
pulled lower than 0.8 Vdc with respect to –In, the output is enabled. The
EN port can be driven by a relay, opto-coupler, or open collector transistor.
Refer to Figures 6 and 7 for the typical enable / disable characteristics. This
port should not be toggled at a rate higher than 1 Hz. The EN port should
also not be driven by or pulled up to an external voltage source.
Figure 30 — IBC Pin Designations
Positive Logic Option
If the EN port is left floating, the IBC output is enabled. Once this port is
pulled lower than 1.4 Vdc with respect to –In, the output is disabled. This
action can be realized by employing a relay, opto-coupler, or open collector
transistor. This port should not be toggled at a rate higher than 1 Hz.
The EN port should also not be driven by or pulled up to an external volt-
age source. The EN port can source up to 2 mA at 5 Vdc. The EN port
should never be used to sink current.
If the IBC is disabled using the EN pin, the module will attempt to restart
approximately every 250ms. Once the module has been disabled for at least
250ms, the turn on delay after the EN pin is enabled will be as shown in
Figure 7.
+Out / -Out – DC Voltage Output Pins
Total load capacitance at the output of the IBC should not exceed the
specified maximum. Owing to the wide bandwidth and low output
impedance of the IBC, low frequency bypass capacitance and significant
energy storage may be more densely and efficiently provided by adding
capacitance at the input of the IBC.
IBC MODULE
Page 12 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
APPLICATIONS NOTE
Parallel Operation
Input Impedance Recommendations
The IBC will inherently current share when operated in an array. Arrays may
be used for higher power or redundancy in an application. Current sharing
accuracy is maximized when the source and load impedance presented to
each IBC within an array are equal. The recommended method to achieve
matched impedances is to dedicate common copper planes within the PCB
to deliver and return the current to the array, rather than rely upon traces
of varying lengths. In typical applications the current being delivered to the
load is larger than that sourced from the input, allowing narrower traces to
be utilized on the input side if necessary. The use of dedicated power
planes is, however, preferable.
To take full advantage of the IBC capabilities, the impedance presented to
its input terminals must be low from DC to approximately 5 MHz.
The source should exhibit low inductance and should have a critically
damped response. If the interconnect inductance is excessive, the IBC input
pins should be bypassed with an RC damper (e.g., 47 µF in series with
0.3 Ω) to retain low source impedance and proper operation. Given the
wide bandwidth of the IBC, the source response is generally the limiting
factor in the overall system response.
Anomalies in the response of the source will appear at the output of the
IBC multiplied by its K factor. The DC resistance of the source should be
kept as low as possible to minimize voltage deviations. This is especially
important if the IBC is operated near low or high line as the
One or more IBCs in an array may be disabled without adversely affecting
operation or reliability as long as the load does not exceed the rated power
of the enabled IBCs.
The IBC power train and control architecture allow bi-directional power
transfer, including reverse power processing from the IBC output to its
input. The IBC’s ability to process power in reverse improves the IBC tran-
sient response to an output load dump.
overvoltage/undervoltage detection circuitry could be activated.
Input Fuse Recommendations
The IBC is not internally fused in order to provide flexibility in configuring
power systems. However, input line fusing of VI Bricks must always be
incorporated within the power system. A fast acting fuse should be placed
in series with the +In port. See safety agency approvals.
Thermal Considerations
The temperature distribution of the VI Brick can vary significantly
with its input/output operating conditions, thermal management and
environmental conditions. Although the PCB is UL rated to 130°C, it is
recommended that PCB temperatures be maintained at or below 125°C.
For maximum long term reliability, lower PCB temperatures are
recommended for continuous operation, however, short periods of
operation at 125°C will not negatively impact performance or reliability.
Application Notes
For IBC and VI Brick application notes on soldering, thermal management,
board layout, and system design visit vicorpower.com.
WARNING: Thermal and voltage hazards. The IBC can operate with surface
temperatures and operating voltages that may be hazardous to personnel.
Ensure that adequate protection is in place to avoid inadvertent contact.
IBC MODULE
Page 13 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
IBC BLOCK DIAGRAM
The Sine Amplitude ConverterTM (SACTM) uses a high frequency resonant tank to transfer energy from input to output. The resonant tank is formed by Cr and
leakage inductance from the main transformer, Lr, as shown in the block diagram. The controller regulates switching frequency of the FET drivers, monitors
current sensing, and provides undervoltage and overvoltage protection.
Figure 31 — IBC Block diagram
IBC MODULE
Page 14 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
MECHANICAL DRAWINGS
Pin Length (X)
(X)
Designator
Length
1
2
3
0.145 [3.68]
0.21 [5.33]
0.18 [4.57]
Figure 32 — IBC outline drawing
Top View
Figure 33 — IBC PCB recommended hole pattern
IBC MODULE
Page 15 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB0xxE120T32xx-xx
Vicor’s comprehensive line of power solutions includes high
density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC
power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are
used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the “Ex-
press Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment and is
not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS
ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW) WITH RE-
SPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR
PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operat-
ing safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be re-
turned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the prod-
uct was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support de-
vices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the prod-
ucts described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
The products described on this data sheet are protected by the following U.S. Patents Numbers:
5,945,130; 6,403,009; 6,710,257; 6,911,848; 6,930,893; 6,934,166; 6,940,013; 6,969,909; 7,038,917;
7,166,898; 7,187,263; 7,361,844; D496,906; D505,114; D506,438; D509,472; and for use under 6,975,098 and 6,984,965
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
IBC MODULE
Page 16 of 16
Rev 1.0
vicorpower.com
800 927.9474
03/2015
IB054E120T32P100 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
IB054E120T32P2-00 | VICOR | 4:1 Intermediate Bus Converter Module: Up to 300 W Output | 获取价格 | |
IB054E120T32P200 | VICOR | 4:1 Intermediate Bus Converter Module: Up to 300 W Output | 获取价格 | |
IB054E120T32P3-00 | VICOR | 4:1 Intermediate Bus Converter Module: Up to 300W Output | 获取价格 | |
IB054E120T32P300 | VICOR | 4:1 Intermediate Bus Converter Module: Up to 300 W Output | 获取价格 | |
IB054E120T40N1-00 | VICOR | 4:1 Intermediate Bus Converter Module: Up to 500 W Output | 获取价格 | |
IB054E120T40N100 | VICOR | 4:1 Intermediate Bus Converter Module: Up to 500 W Output | 获取价格 | |
IB054E120T40N2-00 | VICOR | 4:1 Intermediate Bus Converter Module: Up to 500 W Output | 获取价格 | |
IB054E120T40N200 | VICOR | 4:1 Intermediate Bus Converter Module: Up to 500 W Output | 获取价格 | |