TFS867A [VECTRON]

Filter specification; 过滤器规格
TFS867A
型号: TFS867A
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:224K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs 867a.doc  
Version 1.5  
22.12.2006  
VI TELEFILTER  
Filter specification  
TFS 867A  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance:  
Input:  
23  
0
°C  
dBm  
50  
50  
Output:  
Characteristics  
Remark:  
The maximum attenuation in the pass band is defined as the insertion loss a . The nominal frequency fN is fixed at 867,5 MHz without any tolerance or  
e
limit. The values of absolute attenuation a  
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating  
abs  
temperature range is included in the production tolerance scheme.  
D a t a  
typ. value  
tolerance / limit  
Insertion loss  
a
2,7  
-
dB  
max.  
3,0  
dB  
e
Nominal frequency  
fN  
867,5  
MHz  
Passband  
PB  
-
fN  
±
12,5 MHz  
Pass band ripple  
Absolute attenuation  
0,9  
dB  
max.  
1,5  
dB  
a
abs  
0,3  
750  
915  
MHz  
MHz  
MHz  
MHz  
750  
835  
1000  
2000  
MHz  
MHz  
MHz  
MHz  
50  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
20  
dB  
dB  
dB  
dB  
42  
46  
45  
30  
30  
20  
1000  
Return loss within PB  
Input power level  
12,5  
-
dB  
min.  
9,5  
15  
dB  
max.  
dBm  
Operating temperature range  
Storage temperature range  
OTR  
-
-
- 20 °C ... + 85  
°C  
°C  
- 40 °C ... + 85  
-
Temperature coefficient of frequency  
TC  
*
- 40  
ppm/K  
f
*) f (Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)  
c
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 867a.doc  
Version 1.5  
22.12.2006  
VI TELEFILTER  
Filter specification  
TFS 867A  
2/5  
Filter characteristic  
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
-80  
-90  
-100  
0
-1  
9
6
3
0
-2  
-3  
-4  
-5  
-6  
-7  
-8  
-9  
-10  
2
202  
402  
602  
802  
1002  
1202  
1402  
1602  
1802  
2002  
849  
853  
857  
861  
865  
869  
873  
877  
881  
885  
889  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
2,5 +/-0,1  
4
1
3
1
2
3
4
Input  
Ground  
Output  
Ground  
867A  
U51  
Date code  
1
5
3
,
0
Date code: Year + week  
U
V
W
...  
2006  
2007  
2008  
1,5 ±0,1  
2,3 ±0,15  
50 Test circuit  
1
3
L2  
L1  
2,4  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 867a.doc  
Version 1.5  
22.12.2006  
VI TELEFILTER  
Filter specification  
TFS 867A  
3/5  
Stability characteristics, reliability  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 1 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)  
Packing  
Tape & Reel:  
IEC 286 – 3, with exeption of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters peer reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
9000  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
Tape (all dimensions in mm)  
P1  
Date Code  
W
:
:
:
:
:
:
:
:
:
:
:
:
8,00 + 0,3/- 0,1  
4,00 ± 0,1  
1,50 ± 0,05  
1,75 ± 0,1  
3,50 ± 0,05  
0,75  
Po  
P2  
t
Do  
Po  
Do  
E
F
G(min)  
P2  
P1  
D1(min)  
Ao  
Bo  
2,00 ± 0,1  
4,00 ± 0,1  
1,00  
2,25 ± 0,1  
2,80 ± 0,1  
5,5 ± 0,1  
Ko  
Typ  
PIN Marker  
D1  
Ao  
Ct  
W
2
Reel (all dimensions in mm)  
A
W1  
:330  
: 8,4 +1,5/-0  
W2(max) : 14,4  
N(min)  
C
: 50  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 867a.doc  
Version 1.5  
22.12.2006  
VI TELEFILTER  
Filter specification  
TFS 867A  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 867a.doc  
Version 1.5  
22.12.2006  
VI TELEFILTER  
Filter specification  
TFS 867A  
5/5  
History  
Version  
1.0  
Reason of Changes  
- Generation of development specification  
Name  
Date  
Strehl  
Strehl  
Strehl  
Strehl  
26.01.2006  
21.03.2006  
17.07.2006  
20.11.2006  
1.1  
- Change insertion loss  
1.2  
- Add typical value for pass band ripple, PB2 and insertion loss in PB2  
1.3  
- Add typical value and filter characteristic  
- Generation of filter specification  
1.4  
1.5  
- passband insertion loss modified  
- change return loss limit  
Steiner  
Steiner  
21.12.2006  
22.12.2006  
- package drawing updated  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS868

Filter specification
VECTRON

TFS868A1

Filter Specification
VECTRON

TFS868B

Preliminary specification
VECTRON

TFS868C

Filter Specification
VECTRON

TFS868D

Filter Specification
VECTRON

TFS868E

Filter Specification
VECTRON

TFS868F

Filter Specification
VECTRON

TFS868G

SAW Filter Specification
VECTRON

TFS868H

Filter specification
VECTRON

TFS868L

Filter specification
VECTRON

TFS868N

Filter specification
VECTRON

TFS868_05

Filter specification
VECTRON