VI TELEFILTER  
Filter specification  
TFS 70AC  
1/5  
Measurement condition  
Ambient temperature TA:  
25 °C  
Input power level:  
0 dBm  
Terminating impedances at f *):  
c
Input:  
Output:  
484 || -22,0pF  
127 || -33,4pF  
Characteristics  
Remark: Reference level for the relative attenuation a  
of the TFS 70AC is the minimum of the pass band attenuation a  
. The minimum of the pass  
rel  
min  
band attenuation a  
is defined as the insertion loss a The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3  
min  
e c  
dB filter attenuation level relative to the insertion loss a . The temperature coefficient of frequency Tcf is valid for both the reference frequency f and the  
e
c
frequency response of the filter in the operating temperature range.  
Data  
typ. value  
tolerance / limit  
Insertion loss  
(reference level)  
a
7,5  
dB  
max.  
9,5  
dB  
e
Centre frequency at ambient temperature  
f
70  
MHz  
70,0 ± 0,1  
MHz  
c
Pass band  
PB  
f
c
± 3,6  
0.3  
MHz  
dB  
f
±
2,8  
1
MHz  
dB  
c
Amplitude ripple within PB  
max.  
Relative attenuation  
a
rel  
f
f
.........  
f
f
±
±
3,1  
3,5  
MHz  
MHz  
0,5  
2
dB  
dB  
max.  
max.  
1
3
dB  
dB  
c
c
c
c
±
±
3,1 MHz .........  
f
5,975MHz .........  
f
c
±
20  
MHz  
50  
dB  
min. 40  
dB  
c
Group delay at f  
1,21 µs  
c
Group delay ripple in PB  
68  
ns  
max. 120  
max.8  
ns  
Phase linearity in f ± 2,45 MHz  
4
deg p-p  
deg p-p  
c
Operating temperature range  
Storage temperature range  
-
-
- 30 °C ... + 80  
°C  
°C  
- 40 °C ... + 85  
Temperature coefficient of frequency TCf**  
- 94  
ppm / K  
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values  
only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.  
**) f (Hz) = Tcf(ppm/K) x (T - TA) x fN (MHz)  
c
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 70ac.doc  
Version 1.3  
03.03.2006  
VI TELEFILTER  
Filter specification  
TFS 70AC  
2/5  
Filter characteristic  
0
0
-1  
2.115  
2.01  
-8  
-16  
-24  
-32  
-40  
-48  
-56  
-64  
-72  
-80  
-2  
1.905  
1.8  
-3  
-4  
1.695  
1.59  
-5  
-6  
1.485  
1.38  
-7  
-8  
1.275  
1.17  
-9  
-10  
1.065  
74  
50  
54  
58  
62  
66  
70  
74  
78  
82  
86  
90  
66  
66.8  
67.6  
68.4  
69.2  
70  
70.8  
71.6  
72.4  
73.2  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
13,6Max.  
1
2
3
4
5
6
7
8
9
Ground  
Ground  
Ground  
Ground  
Output  
Output RF Return  
Ground  
Ground  
TFS 70AC  
U09  
1
Date code  
Ground  
10  
11  
12  
Ground  
Input  
Input RF Return  
2,54 ±0,15  
1,5  
2
1
3 4  
12  
11  
5
6
Date code: Year + week  
U
V
2006  
2007  
2008  
W
...  
9 8  
10  
7
0,1  
0,8  
50 Ohm Test circuit  
L1  
11  
12  
5
6
L2  
SAW  
C1  
C2  
1, 2, 3, 4, 7, 8, 9, 10  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 70ac.doc  
Version 1.3  
03.03.2006  
VI TELEFILTER  
Filter specification  
TFS 70AC  
3/5  
Stability characteristics, reliability  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 1 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)  
Packing  
Tape & Reel:  
IEC 286 – 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
1700  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
P1  
Tape (all dimensions in mm)  
W
Po  
Do  
E
: 24,00 +0,30/-0,10  
PIN Marker  
Po  
P2  
t
Do  
:
:
:
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,10  
F
: 11,50 ± 0,10  
G(min)  
P2  
:
:
0,60  
2,00 ± 0,1  
P1  
: 12,00 ± 0,1  
D1(min)  
Ao  
:
:
1,50  
7,10 ± 0,10  
Ko  
Typ  
Date Code  
D1  
Ao  
Bo  
Ct  
: 13,90 ± 0,10  
: 21,5 ± 0,1  
W
2
Reel (all dimensions in mm)  
A
:330  
W1  
: 24,4  
W2(max) : 30,4  
C
A
N(min)  
C
: 60  
: 13,0  
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 70ac.doc  
Version 1.3  
03.03.2006  
VI TELEFILTER  
Filter specification  
TFS 70AC  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 70ac.doc  
Version 1.3  
03.03.2006  
VI TELEFILTER  
Filter specification  
TFS 70AC  
5/5  
History  
Version  
Reason of Changes  
- generate development specification  
Name  
Date  
1.0  
1.1  
Pfeiffer  
Chilla  
14.05.2003  
08.09.2003  
- fN changed to fc generate development specification  
- remove nominal frequency fN  
1.2  
1.3  
- changed to filter specitication  
- terminating impedances added  
- typical values added  
- group delay at fN changed to 1,21 µs typical value  
- matching network added  
Chilla  
Chilla  
24.11.2003  
03.03.2006  
- filter characteristics added  
- test circuit updated  
- RoHS compliant added  
- air reflow temperature conditions updated  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS70AG

Filter specification
VECTRON

TFS70AH

Filter specification
VECTRON

TFS70AK

Filter specification
VECTRON

TFS70AM

Filter specification
VECTRON

TFS70AP

Filter Specification
VECTRON

TFS70AR

Filter specification
VECTRON

TFS70AS

Filter specification
VECTRON

TFS70AT

VI TELEFILTER
VECTRON

TFS70AU

VI TELEFILTER
VECTRON

TFS70AV

Filter specification
VECTRON

TFS70AW

Filter specification
VECTRON

TFS70AW_05

Filter specification
VECTRON