TFS120E [VECTRON]
Filter specification; 过滤器规格型号: | TFS120E |
厂家: | Vectron International, Inc |
描述: | Filter specification |
文件: | 总5页 (文件大小:251K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Filename: tfs 120e.doc
Version 1.2
27.07.2006
VI TELEFILTER
Filter specification
TFS 120E
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
23
0
°C
dBm
1080 Ω || -7,4 pF
1250 Ω || -6,7 pF
Output:
Characteristics
Remark:
The reference level for the relative attenuation a of the TFS 120E is the minimum of the pass band attenuation a
. The minimum of the pass band
min
rel
attenuation a
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB
min
filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed at 120 MHz without any tolerance. The given values for both the
e c
e
N
relative attenuation a and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency f is shifted due to the
rel
c
temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .
f
c
D a t a
typ. value
tolerance / limit
a
6
dB
max.
7
dB
Insertion loss
e
(reference level)
fN
-
120
-
MHz
Nominal frequency
Centre frequency
fC
120
MHz
kHz
fN ± 100
kHz
1 dB Passband
Relative attenuation
fN
PB
290
a
rel
... fN
±
0,1
MHz
0,5
dB
max.
1
dB
fN
fN
fN
fN
±
±
±
±
0,3
0,5
0,7
1
MHz ... fN
MHz ... fN
MHz ... fN
MHz ... fN
±
±
±
±
0,5
0,7
1
MHz
MHz
MHz
MHz
15
32
39
48
dB
dB
dB
dB
min.
min.
min.
min.
10
25
35
45
dB
dB
dB
dB
80
650
ns
max.
max.
max.
1000
18
ns
Group delay ripple within PB
Input power level **
dBm
V
10
Permissible DC voltage between any two terminals
- 35 °C ... + 85
- 40 °C ... + 85
°C
°C
Operating temperature range
OTR
-
Storage temperature range
-
29
°C
Frequency inversion temperature
TC ***
f
Temperature coefficient of frequency
-0,04
ppm/K²
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team
**) This power level is only allowed for short term operation (10% of the life time), the max. input power for continuous operation is max.10dBm only
***) ∆f(Hz) = TC (ppm/K2) x (T-T0)2 x f (MHz)
f
To
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 120e.doc
Version 1.2
27.07.2006
VI TELEFILTER
Filter specification
TFS 120E
2/5
Filter characteristic
0
0
-1
8.88
8.13
7.38
6.63
5.88
5.13
4.38
3.63
2.88
2.13
-8
-16
-24
-32
-40
-48
-56
-64
-72
-80
-2
-3
-4
-5
-6
-7
-8
-9
-10
1.38
117.607
118.0856
118.5642
119.0428
119.5214
120
120.4786
120.9572
121.4358
121.9144
122.393
119.75
119.8
119.85
119.9
119.95
120
120.05
120.1
120.15
120.2
120.25
frequency in MHz
frequency in MHz
Construction and pin connection
(All dimensions in mm)
13,3±0,2
1
Input
2
3
4
5
6
7
8
9
Ground
Ground
Ground
Output
Output
Ground
Ground
Ground
Input
TFS 120E
●
Date code
10
1,0±0,2
5
1
Date code: Year + week
U
V
W
...
2006
2007
2008
1,91±0,2
7,62±0,2
10
6
200 Ω Test circuit
1
5
6
L
L
L1
L2
C1
C
SAW
10
2, 3, 4, 7, 8, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 120e.doc
Version 1.2
27.07.2006
VI TELEFILTER
Filter specification
TFS 120E
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
Date Code
W
: 24,00 +0,30/-0,10
Po
P2
t
Do
Po
Do
E
:
:
:
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,10
F
: 11,50 ± 0,10
G(min)
P2
:
:
0,60
2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
Ao
:
:
1,50
7,10 ± 0,10
Ko
Typ
PIN Marker
D1
Ao
Bo
Ct
: 13,90 ± 0,10
: 21,5 ± 0,1
W
2
Reel (all dimensions in mm)
A
:330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
C
: 60
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 120e.doc
Version 1.2
27.07.2006
VI TELEFILTER
Filter specification
TFS 120E
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
> 150°C
> 217°C
Peak temperature
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 120e.doc
Version 1.2
27.07.2006
VI TELEFILTER
Filter specification
TFS 120E
5/5
History
Version
Reason of Changes
Name
Date
1.0
generate development specification
Martens
Strehl
27.10.2004
18.05.2006
27.07.2006
1.1
change stability characteristics and correct relative attenuation
1.2
-terminating impedances, typical values, filter characteristics and matching configuration added Pfeiffer
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明