TFS120E [VECTRON]

Filter specification; 过滤器规格
TFS120E
型号: TFS120E
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:251K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs 120e.doc  
Version 1.2  
27.07.2006  
VI TELEFILTER  
Filter specification  
TFS 120E  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance: *  
Input:  
23  
0
°C  
dBm  
1080 || -7,4 pF  
1250 || -6,7 pF  
Output:  
Characteristics  
Remark:  
The reference level for the relative attenuation a of the TFS 120E is the minimum of the pass band attenuation a  
. The minimum of the pass band  
min  
rel  
attenuation a  
is defined as the insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB  
min  
filter attenuation level relative to the insertion loss a . The nominal frequency f is fixed at 120 MHz without any tolerance. The given values for both the  
e c  
e
N
relative attenuation a and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency f is shifted due to the  
rel  
c
temperature coefficient of frequency TC in the operating temperature range and due to a production tolerance for the centre frequency f .  
f
c
D a t a  
typ. value  
tolerance / limit  
a
6
dB  
max.  
7
dB  
Insertion loss  
e
(reference level)  
fN  
-
120  
-
MHz  
Nominal frequency  
Centre frequency  
fC  
120  
MHz  
kHz  
fN ± 100  
kHz  
1 dB Passband  
Relative attenuation  
fN  
PB  
290  
a
rel  
... fN  
±
0,1  
MHz  
0,5  
dB  
max.  
1
dB  
fN  
fN  
fN  
fN  
±
±
±
±
0,3  
0,5  
0,7  
1
MHz ... fN  
MHz ... fN  
MHz ... fN  
MHz ... fN  
±
±
±
±
0,5  
0,7  
1
MHz  
MHz  
MHz  
MHz  
15  
32  
39  
48  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
10  
25  
35  
45  
dB  
dB  
dB  
dB  
80  
650  
ns  
max.  
max.  
max.  
1000  
18  
ns  
Group delay ripple within PB  
Input power level **  
dBm  
V
10  
Permissible DC voltage between any two terminals  
- 35 °C ... + 85  
- 40 °C ... + 85  
°C  
°C  
Operating temperature range  
OTR  
-
Storage temperature range  
-
29  
°C  
Frequency inversion temperature  
TC ***  
f
Temperature coefficient of frequency  
-0,04  
ppm/K²  
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference  
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team  
**) This power level is only allowed for short term operation (10% of the life time), the max. input power for continuous operation is max.10dBm only  
***) f(Hz) = TC (ppm/K2) x (T-T0)2 x f (MHz)  
f
To  
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 120e.doc  
Version 1.2  
27.07.2006  
VI TELEFILTER  
Filter specification  
TFS 120E  
2/5  
Filter characteristic  
0
0
-1  
8.88  
8.13  
7.38  
6.63  
5.88  
5.13  
4.38  
3.63  
2.88  
2.13  
-8  
-16  
-24  
-32  
-40  
-48  
-56  
-64  
-72  
-80  
-2  
-3  
-4  
-5  
-6  
-7  
-8  
-9  
-10  
1.38  
117.607  
118.0856  
118.5642  
119.0428  
119.5214  
120  
120.4786  
120.9572  
121.4358  
121.9144  
122.393  
119.75  
119.8  
119.85  
119.9  
119.95  
120  
120.05  
120.1  
120.15  
120.2  
120.25  
frequency in MHz  
frequency in MHz  
Construction and pin connection  
(All dimensions in mm)  
13,3±0,2  
1
Input  
2
3
4
5
6
7
8
9
Ground  
Ground  
Ground  
Output  
Output  
Ground  
Ground  
Ground  
Input  
TFS 120E  
Date code  
10  
1,0±0,2  
5
1
Date code: Year + week  
U
V
W
...  
2006  
2007  
2008  
1,91±0,2  
7,62±0,2  
10  
6
200 Test circuit  
1
5
6
L
L
L1  
L2  
C1  
C
SAW  
10  
2, 3, 4, 7, 8, 9  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 120e.doc  
Version 1.2  
27.07.2006  
VI TELEFILTER  
Filter specification  
TFS 120E  
3/5  
Stability characteristics, reliability  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 1 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 – 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: three times max.;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)  
Packing  
Tape & Reel:  
IEC 286 – 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
reel of empty components at start:  
reel of empty components at start including leader:  
trailer:  
1700  
min. 300 mm  
min. 500 mm  
min. 300 mm  
Pull Off Direction  
P1  
Tape (all dimensions in mm)  
Date Code  
W
: 24,00 +0,30/-0,10  
Po  
P2  
t
Do  
Po  
Do  
E
:
:
:
4,00 ± 0,1  
1,50 +0,1/-0  
1,75 ± 0,10  
F
: 11,50 ± 0,10  
G(min)  
P2  
:
:
0,60  
2,00 ± 0,1  
P1  
: 12,00 ± 0,1  
D1(min)  
Ao  
:
:
1,50  
7,10 ± 0,10  
Ko  
Typ  
PIN Marker  
D1  
Ao  
Bo  
Ct  
: 13,90 ± 0,10  
: 21,5 ± 0,1  
W
2
Reel (all dimensions in mm)  
A
:330  
W1  
: 24,4 +2/-0  
W2(max) : 30,4  
N(min)  
C
: 60  
: 13,0 +0,5/-0,2  
C
A
N
W
1
The minimum bending radius is 45 mm.  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 120e.doc  
Version 1.2  
27.07.2006  
VI TELEFILTER  
Filter specification  
TFS 120E  
4/5  
Air reflow temperature conditions  
Conditions  
Exposure  
Average ramp-up rate (30°C to 217°C)  
> 100°C  
less than 3°C/second  
between 300 and 600 seconds  
> 150°C  
> 217°C  
Peak temperature  
between 240 and 500 seconds  
between 30 and 150 seconds  
max. 260°C  
Time within 5°C of actual peak temperature  
Cool-down rate (Peak to 50°C)  
Time from 30°C to Peak temperature  
between 10 and 30 seconds  
less than 6°C/second  
no greater than 300 seconds  
Chip-mount air reflow profile  
Temperature / °C  
max. 260°C  
217°C  
Time / s  
max. 300 s  
10 ... 30 s  
30 ... 150 s  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs 120e.doc  
Version 1.2  
27.07.2006  
VI TELEFILTER  
Filter specification  
TFS 120E  
5/5  
History  
Version  
Reason of Changes  
Name  
Date  
1.0  
generate development specification  
Martens  
Strehl  
27.10.2004  
18.05.2006  
27.07.2006  
1.1  
change stability characteristics and correct relative attenuation  
1.2  
-terminating impedances, typical values, filter characteristics and matching configuration added Pfeiffer  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS121

Filter Specification
VECTRON

TFS121B

Filter specification
VECTRON

TFS1220

Filter specification
VECTRON

TFS1220B

VI TELEFILTER
VECTRON

TFS1220_03

The filter is single ended driven
VECTRON

TFS1237

Filter specification
VECTRON

TFS124

Filter Specification
VECTRON

TFS125A

Filter Specification
VECTRON

TFS125B

Filter Specification
VECTRON

TFS125C

Filter specification
VECTRON

TFS125C_04

Filter specification
VECTRON

TFS125D

Filter specification
VECTRON