OX-5010-EAE-2582-10 [VECTRON]
Oven Controlled Crystal Oscillator; 恒温晶体振荡器型号: | OX-5010-EAE-2582-10 |
厂家: | Vectron International, Inc |
描述: | Oven Controlled Crystal Oscillator |
文件: | 总5页 (文件大小:196K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
OX-501
Oven Controlled Crystal Oscillator
Preliminary
Features
Typical Applications
Base Stations
6-Pin SMD package
Fast Warm-up
Test Equipment
Femto Basestation
TCXO Replacement for better short term stability
Military Communication Equipment
Frequency Range
10 MHz – 100 MHz
Standard Frequencies
10; 12.8; 16.384; 19.44; 20.00; 30.72; 38.88; 51.84 MHz
Frequency stabilities1 [AT Cut Crystal-Standard-10 to 100 MHz]
Parameter
Min
-100
-250
-250
Min
Typ
Max
+100
+250
+250
Max
+0.5
+20
Units
ppb
Operating temperature range
-20 … +70°C
vs. operating temperature range
(Referenced to +25°C)
ppb
-20 … +70°C
ppb
-40… +85°C
Typ
Units
ppm
ppb
Condition
Parameter
Initial tolerance
-0.5
-20
at time of shipment, nominal EFC
VS ± 5% static
vs. supply voltage change
vs. load change
-20
+20
ppb
Load ± 5% static
vs. aging / day
vs aging / year
vs. aging / year
-10
+10
ppb
after 30 days of operation
≤ 60MHz; after 30 days of operation
>60MHz; after 30 days of operation
-300
-500
+300
+500
ppb
ppb
to ± 200ppb of final frequency (1 hour
Warm-up Time
2
minutes
reading) @ +25°C
htttp://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 1/5
Frequency stabilities1 [SC Cut Crystal-Option-10 to 52 MHz]
Parameter
vs. operating temperature range
(Referenced to +25°C)
Parameter
Min
-30
Typ
Max
+30
Units
ppb
Operating temperature range
-20 … +70°C
-50
+50
ppb
-40… +85°C
Min
-0.2
-10
Typ
Max
+0.2
+10
Units
ppm
ppb
Condition
Initial tolerance
at time of shipment, nominal EFC
VS ± 5% static
vs. supply voltage change
vs. load change
-10
+10
ppb
Load ± 5% static
vs. aging / day
-5.0
-100
-500
+5.0
+100
+500
ppb
after 30 days of operation
≤ 60MHz; after 30 days of operation
>60MHz; after 30 days of operation
vs aging / year
ppb
vs. aging / year
ppb
to ± 100ppb of final frequency (1 hour
Warm-up Time
2
minutes
reading) @ +25°C
Supply Voltage (Vs)
Parameter
Min
Typ
Max
3.465
2.2
Units
VDC
Condition
Supply voltage [Standard]
Power consumption
3.135
3.3
Watts
Watts
during warm-up
0.7
steady state @ +25°C
RF Output
Parameter
Signal [Standard]
Load
Min
Typ
Max
Units
Condition
HCMOS
15
pF
VDC
VDC
%
Signal Level (Vol)
Signal Level (Voh)
Duty cycle
0.4
55
with Vs=3.3V and 15pF load
with Vs=3.3V and 15pF load
@ (Voh-Vol)/2
2.4
45
htttp://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 2/5
Frequency Tuning (EFC)
Parameter
Tuning Range
Tuning Range
Min
Typ
Max
Units
Condition
Fixed OCXO; No adjust
±5.0
±1.0
±12
±3
ppm
ppm
with AT cut Crystal
with SC cut Crystal
Linearity
Tuning Slope
10%
Positive
Control Voltage Range
0.0
1.4
2.8
VDC
with Vs=3.3V
Additional Parameters
Parameter
Min
Typ
Max
-65
Units
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
g
Condition
Phase Noise3
1
10
100
1
Hz
Hz
@ 10 MHz
-95
-120
-140
-145
8.0
Hz
kHz
kHz
10
Weight
Processing & Packing
Handling & Processing Note
Absolute Maximum Ratings
Parameter
Supply voltage (Vs)
Min
Typ
Max
5.5
Units
V
Condition
with Vs=5.0VDC
Output Load
50
pF
Operable temperature range
Storage temperature range
-55
-55
+85
+125
°C
°C
Notes:
1 Contact factory for improved stabilities or additional product options. Not all options and codes are available at all
frequencies.
2 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage,
frequency control voltage, load, temperature (25°C)
3 Phase noise degrades with increasing output frequency.
4 Subject to technical modification.
5 Contact factory for availability.
htttp://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 3/5
Enclosure
OX-501
Height “H”
9,9
Pin Length “L”
N.A
Pin Connections
1
2
3
4
5
6
Electronic Frequency Control Input (EFC)
Enable
Ground (Case)
RF Output
Uref
Supply Voltage Input
Standard Shipping Methode (For OX-501 Type)
Lage im Gurt
Position in tape
Pin 1
Abwickelrichtung
Unwinding direction
A
X
B
Gurtunterseite
Tape buttom side
K
Gurtoberseite
Tape upper side
*bei W ≤ 24 mm nur untere Lochreihe
∗by W ≤ 24 mm only lower hole line
P
Production tolerance complying DIN IEC 286-3
Enclosure Type
Tape width W [mm]
Quantity per meter
Quantity per reel
Dimension P
Typ OX-501
N.A
N.A
N.A
N.A
htttp://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 4/5
Recommanded Reflow Profile
Pb-Free Assembly/
Sn-Pb Assembly
Pb-Free Assembly/
Sn-Pb Assembly
Profile Feature
Profile Feature
Average ramp-up rate (TL to Tp)
3°C/second max.
Time 25°C to Peak Temperature
8 minutes max.
Preheat -Temperature Min TSmin
-Temperature Min T
150°C
200°C
60-180 seconds
Time maintainted above
-Temperature (TL)
-Time (tL)
217°C
60-150 seconds
-Time (min to max) stmSax
TSmax to TL-Ramp-up Rate
3°C/second max
Time maintainted above
-Temperature (TL)
-Time (tL)
217°C
60-150 seconds
Time within 5°C of actual Peak
Temperature (tP)
20-40 seconds
Peak Temperature (TP)
max 260°C
Ramp-down Rate
6°C/ second max
Note: All temperatures refer to topside of the package, measured on the package body surface.
How to order this product:
Use this worksheet to forward the following information to your factory representative :
Supply Voltage RF Output
Temperatur
Range
Frequency
Control
Model
Height
-
Stability
-
Frequency
Code
Code
-
OX-501
0
-
B
A
E
-
108
0
-
10MHz
Model Code:
Frequency Control:
501: SMD Version
0:
1:
2:
No Tuning
±5.0...±12 ppm
±1.0...±3.0 ppm
Height:
Stability Code:
0:
9,9 mm
Temperature Range:
Supply Voltage Code:
E: 3,3 V
E:
J:
-40...+85°C
-20...+70°C
0...+50°C
258: ±25ppb
508: ±50ppb
107: ±100ppb
257: ±250ppb
RF Output Code:
A: HCMOS
P:
htttp://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100
OX-501 page: 5/5