F16-2250-C2 [TRIAD]

Split Bobbin Power Transformer, 36VA, ROHS COMPLIANT;
F16-2250-C2
型号: F16-2250-C2
厂家: TRIAD MAGNETICS    TRIAD MAGNETICS
描述:

Split Bobbin Power Transformer, 36VA, ROHS COMPLIANT

变压器
文件: 总1页 (文件大小:150K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CLASS 2/3 TRANSFORMER  
F16-2250-C2  
Description:  
The F16-2250-C2 is a single primary and dual secondary, split bobbin design  
which operates with an input of 115V. The secondaries are 8V @ 2.25A each.  
They can be used independently (up to 300V difference between them) or in  
series for double the voltage or in parallel for double the current. The split  
bobbin design eliminates the need for costly electrostatic shielding.  
Electrical Specifications (@25C)  
1. Maximum Power: 36.0VA  
2. Primary: 115V, 50/60 Hz  
3. Secondaries: 8.0V @ 2.25A each  
4. Voltage Regulation: 25% TYP @ full load to no load  
5. Temperature Rise: 25C TYP  
W
6. Hipot tested 100% at 4200 VRMS pri to sec  
7. Hipot tested 100% at 2160 VRMS sec to sec  
8. Recommended fuse (fuse on primary): Cooper/Bussman, Type MDL, rated  
500mA, 250V  
Construction:  
Three flange bobbin construction with primaries and secondaries wound side by  
side for low capacitive coupling. UL Class F Insulation System (155°C).  
E
Agency File:  
L
UL: File E65390, UL 5085-3 (1585), Class 2 not wet / Class 3 wet Transformer  
cUL: File E65390, UL 5085-3 (1585) For Canadian Use (CSA 22.2, No.66.3-06)  
H
Max Dimensions:  
Units in inches.  
1
4
H
W
L
A
B
C
D
E
F
1.634 2.205 2.638 0.416 0.416 1.870 0.041 0.020 0.236  
Weight: 1.10 lbs  
D
F
Schematic:  
5
A
A
8V @ 2.25A  
5
8
1
6
115V  
50/60 Hz  
7
B
4
8V @ 2.25A  
8
C
RoHS Compliance: As of manufacturing date February 2005, all standard products  
meet the requirements of 2011/65/EU, known as the RoHS initiative.  
1
4
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2  
and 5085-3, respectively.  
0.06" DIAMETER  
HOLE  
Board Layout  
*Upon printing, this document is considered “uncontrolled”. Please contact Triad  
Magnetics website for the most current version. For soldering and washing information  
please see http://www.triadmagnetics.com/faq.html  
www.TriadMagnetics.com  
460 Harley Knox Blvd.  
Phone: (951) 277-0757  
Publish Date: March 13, 2017  
Perris, California 92571  
Fax: (951) 277-2757  

相关型号:

F16-400

Split Bobbin Power Transformer, 6VA, ROHS COMPLIANT
TRIAD

F16002

~50° wide beam compatible with LEDiL HEKLA
LEDIL

F16002_18

~50° wide beam compatible with LEDiL HEKLA
LEDIL

F16007

~90° wide beam
LEDIL

F16007_18

~90° wide beam
LEDIL

F1600DC45

Standard SRAM, 64KX1, 45ns, CMOS, CDIP22, 0.300 INCH, SIDE BRAZED, DIP-22
FAIRCHILD

F1600DC55

Standard SRAM, 64KX1, 55ns, CMOS, CDIP22, 0.300 INCH, SIDE BRAZED, DIP-22
FAIRCHILD

F1600DC70

Standard SRAM, 64KX1, 70ns, CMOS, CDIP22, 0.300 INCH, SIDE BRAZED, DIP-22
FAIRCHILD

F1600DMQB55

Standard SRAM, 64KX1, 55ns, CMOS, CDIP22, 0.300 INCH, SIDE BRAZED, DIP-22
FAIRCHILD

F1600LC55

Standard SRAM, 64KX1, 55ns, CMOS, CQCC22, LCC-22
FAIRCHILD

F1600LC70

Standard SRAM, 64KX1, 70ns, CMOS, CQCC22, LCC-22
FAIRCHILD

F1600LMQB55

Standard SRAM, 64KX1, 55ns, CMOS, CQCC22, LCC-22
FAIRCHILD