TPS120-46 [TOTAL-POWER]

Telecommunications/Business machines;
TPS120-46
型号: TPS120-46
厂家: TOTAL POWER INTERNATIONAL    TOTAL POWER INTERNATIONAL
描述:

Telecommunications/Business machines

文件: 总4页 (文件大小:1772K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TOTAL POWER INT.  
TPS120 SWITCHING MODE 120W U CHANNEL POWER SUPPLY  
KEY FEATURES  
*Universal input  
*Built-in EMI filter  
*Optional remote sense on main output  
*Optional constant current charger  
*Optional±12VDC/±24VDC/±48VDC input  
*Optional cover  
*Optional constant current change (for single output)  
APPLICATIONS  
*Telecommunications/Business machines  
*Computer peripherals/Medical instruments  
*Test & industrial equipments  
ELECTRICAL SPECIFICATIONS  
EMI & EMC  
*FCC part 15, Class B  
INPUT  
*CISPR 22 / EN55022, Class B  
*VCCI ,Class 2  
*Input range-----------90~264 VAC, universal  
*Frequency------------47~63Hz  
*CE, EN61000-3-2 (Class A) and –3 ; EN61000-4-2,  
-3 , -4 , -5 , -6 and -11  
*Inrush current--------38A typical ,Cold start @25,115VAC  
*Efficiency------------65% ~85% typical at full load  
*EMI filter------------FCC Class B conducted, CISPR 22  
Class B conducted, EN55022 class B  
Conducted  
SAFETY APPROVAL  
*Line regulation----- +/- 0.5% typical  
*UL1950 / c UL  
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)  
*TUV EN60950  
OUTPUT  
*Optional UL 2601 (EMI Class A)(COMPLY WITH)  
*Maximum power----120W with 30 CFM forced air  
*Hold-up time --------10ms typical at full load and 115 VAC  
nominal line  
ENVIRONMENTAL  
*Overload protection-Short circuit protection  
*Overvoltage  
*Operating temperature :  
0 to 50ambient; derate each output at 2.5% per  
degree from 50to 70℃  
*Humidity:  
protection ------------Main output 20% to 40% above  
nominal output  
*Ripple/Noise -------- +/- 1% Max. @full load  
(Optional +/-0.5 % per inquiry)  
Operating; non-condensing, 5% to 95%  
*Vibration :  
10~55 Hz at 1G 3 minutes period, 30 minutes along  
X, Y and Z axis  
Power Derating Curve  
120W  
30 CFM Forced Air Cooling  
90W  
*Storage temperature:  
-40 to 85℃  
*Temperature coefficient:  
+/- 0.05% per degree C  
Output  
Power  
(Watts)  
Natural  
Convection  
Cooling  
60W  
30W  
0W  
60W  
45W  
*MTBF demonstrated:  
0
10  
20 30 40 50 60 70  
>100,000 hours at full load and 25ambient  
conditions  
°
Ambient Temperature( C)  
TOTAL POWER INT. TEL: 877-646-0900 FAX: 978-453-7395  
E-mail:sales@total-power.com http://www.total-power.com  
-1-  
TOTAL POWER  
TPS120 SWITCHING MODE 120W U CHANNEL POWER SUPPLIES  
OUTPUT  
ADJUSTMENT MAXIMUM OUTPUT  
PEAK OUTPUT  
MINIMUM OUTPUT  
TOTAL  
RIPPLE & NOISE  
PEAK OUTPUT  
MODEL  
VOLTAGE  
RANGE CURRENT  
CURRENT(NOTE1)  
CURRENT  
REGULATION(NOTE3)  
%P-P(NOTE2)  
POWER(NOTE1)  
SINGLE OUTPUT MODEL SELECTION CHART  
±10% Typical  
±10% Typical  
±10% Typical  
±10% Typical  
±10% Typical  
±10% Typical  
±10% Typical  
±10% Typical  
±10% Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
TPS120-10  
TPS120-11  
TPS120-12  
TPS120-13  
TPS120-14  
TPS120-15  
TPS120-16  
TPS120-17  
TPS120-18  
+5V  
+12V  
+15V  
+24V  
+48V  
+13.5V  
+56V  
+18V  
+3.3V  
24A  
10A  
8A  
30A  
12.5A  
10A  
0A  
0A  
0A  
0A  
0A  
0A  
0A  
0A  
0A  
±3%  
±3%  
±3%  
±3%  
±3%  
±3%  
±3%  
±3%  
±5%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1.5%  
5A  
6.3A  
3.1A  
11.1A  
2.8A  
8.4A  
37.5A  
2.5A  
8.9A  
2.2A  
6.7A  
30A  
DUAL OUTPUT MODEL SELECTION CHART  
±10% Typical  
+5 V  
+12V  
+5 V  
12A  
15A  
6.2A  
15A  
3.1A  
15A  
15A  
6.3A  
6.3A  
5A  
1.2A  
0.5A  
1.2A  
0.25A  
1.2A  
1.2A  
0.5A  
0.5A  
0.4A  
0.4A  
2A  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1.5%  
±1%  
±1%  
±1%  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
TPS120-20  
TPS120-21  
TPS120-22  
TPS120-23  
TPS120-24  
TPS120-25  
TPS120-26  
Fixed  
5A  
±10% Typical  
Fixed  
12A  
2.5A  
12A  
12A  
5A  
+24V  
+5 V  
±10% Typical  
Fixed  
- 5 V  
±10% Typical  
Fixed  
+12V  
- 12 V  
+15 V  
- 15 V  
+3.3V  
+12 V  
+ 5 V  
+48V  
5A  
±10% Typical  
Fixed  
4A  
4A  
5A  
Fixed  
20A  
1A  
25A  
1.3A  
5A  
±10% Typical  
±10% Typical  
Fixed  
0.1A  
0.4A  
0.2A  
4A  
2A  
2.5A  
TRIPLE OUTPUT MODEL SELECTION CHART  
±10% Typical  
+ 5V  
+12V  
- 5 V  
+ 5V  
+12V  
-12V  
+ 5V  
+15V  
-15V  
+ 5V  
+15V  
-5 V  
12A  
4.5A  
0.6A  
12A  
4.5A  
0.6A  
12A  
3.5A  
0.6A  
15A  
3A  
15A  
5.6A  
0.8A  
15A  
1.2A  
0.45A  
0.06A  
1.2A  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±5%  
±5%  
±10%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
Fixed  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
TPS120-30  
TPS120-31  
TPS120-32  
TPS120-33  
TPS120-34  
TPS120-35  
Fixed  
±10% Typical  
Fixed  
5.6A  
0.8A  
15A  
0.45A  
0.06A  
1.2A  
Fixed  
±10% Typical  
Fixed  
4.4A  
0.8A  
18.8A  
3.8A  
0.6A  
17.5A  
3.8A  
0.8A  
13.8A  
3.1A  
0.8A  
13.8A  
6.3A  
1.3A  
0.35A  
0.06A  
1.5A  
Fixed  
±10% Typical  
Fixed  
0.3A  
Fixed  
0.5A  
14A  
3A  
0.05A  
1.4A  
±10% Typical  
Fixed  
+ 5V  
+15V  
-12V  
+ 5 V  
+24V  
-12V  
+ 5V  
+12V  
- 12V  
0.3A  
Fixed  
0.6A  
11A  
2.5A  
0.6A  
11A  
5A  
0.06A  
1.1A  
±10% Typical  
Fixed  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
0.25A  
0.06A  
1.1A  
Fixed  
±10% Typical  
TPS120-36  
TPS120-37  
TPS120-38  
Fixed  
Fixed  
0.5A  
1A  
0.1A  
±10% Typical  
+ 5V  
+12V  
+24V  
11A  
3.5A  
1A  
13.8A  
4.4A  
1.3A  
1.1A  
0.35A  
0.1A  
±5%  
±5%  
±1%  
±1%  
±1%  
Fixed  
Fixed  
±10%  
±10% Typical  
+ 5V  
+12V  
+48V  
8A  
3A  
1A  
10A  
3.8A  
1.3A  
0.8A  
0.3A  
0.1A  
±5%  
±5%  
±1%  
±1%  
±1%  
Fixed  
Fixed  
±10%  
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395  
E-mail:sales@total-power.com http://www.total-power.com  
2 –  
TOTAL POWER  
TPS120 SWITCHING MODE 120W U CHANNEL POWER SUPPLIES  
OUTPUT  
ADJUSTMENT MAXIMUM OUTPUT  
PEAK OUTPUT  
MINIMUM OUTPUT  
TOTAL  
RIPPLE & NOISE  
PEAK OUTPUT  
MODEL  
VOLTAGE  
RANGE CURRENT  
CURRENT(NOTE1)  
CURRENT  
REGULATION(NOTE3)  
%P-P(NOTE2)  
POWER(NOTE1)  
QUAD OUTPUT MODEL SELECTION CHART  
±10% Typical  
+ 5V  
+12V  
-12V  
-5V  
12A  
4.5A  
0.5A  
0.5A  
12A  
4A  
15A  
5.6A  
0.6A  
0.6A  
15A  
1.2A  
0.45A  
0.05A  
0.05A  
1.2A  
0.4A  
0.1A  
0.1A  
1.2A  
0.3A  
0.1A  
0.1A  
0.8A  
0.35A  
0.1A  
0.2A  
0.8A  
0.2A  
0.1A  
0.1A  
0.8A  
0.2A  
0.1A  
0.2A  
0.3A  
0.1A  
0.25A  
0.2A  
±5%  
±5%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
Fixed  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
150W Typical  
TPS120-40  
TPS120-41  
TPS120-42  
TPS120-43  
TPS120-44  
TPS120-45  
TPS120-46  
Fixed  
±10%  
±10%  
±5%  
Fixed  
±10% Typical  
Fixed  
+ 5V  
+12V  
-12V  
-5 V  
5A  
±5%  
Fixed  
1A  
1.3A  
1.3A  
15A  
±10%  
±10%  
±5%  
Fixed  
1A  
±10% Typical  
Fixed  
+ 5V  
+12V  
-15V  
+15V  
+ 5V  
+12V  
- 12V  
- 15V  
+ 5V  
+12V  
- 12V  
+48V  
+ 5V  
+12V  
- 12V  
+24V  
+ 5V  
+12V  
- 12V  
+36V  
12A  
3A  
3.8A  
1.3A  
1.3A  
10A  
±5%  
Fixed  
1A  
±10%  
±10%  
±5%  
Fixed  
1A  
±10% Typical  
Fixed  
8A  
3.5A  
1A  
4.4A  
1.3A  
2.5A  
10A  
±5%  
Fixed  
±10%  
±10%  
±5%  
Fixed  
2A  
±10% Typical  
Fixed  
8A  
2A  
2.5A  
1.3A  
1.3A  
10A  
±5%  
Fixed  
1A  
±10%  
±10%  
±5%  
Fixed  
1A  
±10% Typical  
Fixed  
8A  
2A  
2.5A  
1.3A  
2.5A  
3.8A  
1.3A  
3.1A  
2.5A  
±5%  
Fixed  
1A  
±10%  
±10%  
±5%  
Fixed  
2A  
±10% Typical  
Fixed  
3A  
1A  
±5%  
Fixed  
2.5A  
2A  
±10%  
±10%  
Fixed  
NOTES:  
1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.  
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal line, 0.1μF and 47μF Cap. on outputs.  
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.  
4) Detailed engineering specification of each model is available for inquiry.  
5) Special output voltage/current inquiry is welcomed.  
6) Specifications subject to change without notice.  
7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover.  
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395  
E-mail:sales@total-power.com http://www.total-power.com  
-3-  

相关型号:

TPS1205

2W 6KVDC Isolated Dual Output DC/DC Converters
TOPPOWER

TPS1205A

2W 6KVDC Isolated Dual Output DC/DC Converters
TOPPOWER

TPS1206

PTC-Thickfilm Temperature Sensors
TELEDYNE

TPS1209

2W 6KVDC Isolated Dual Output DC/DC Converters
TOPPOWER

TPS1209A

2W 6KVDC Isolated Dual Output DC/DC Converters
TOPPOWER

TPS1211-Q1

具有保护和诊断功能的汽车用 3.5V 至 40V 高侧驱动器
TI

TPS12110AQDGXRQ1

具有保护和诊断功能的汽车用 3.5V 至 40V 高侧驱动器 | DGX | 19 | -40 to 125
TI

TPS12111LQDGXRQ1

具有保护和诊断功能的汽车用 3.5V 至 40V 高侧驱动器 | DGX | 19 | -40 to 125
TI

TPS1212

2W 6KVDC Isolated Dual Output DC/DC Converters
TOPPOWER

TPS1215

2W 6KVDC Isolated Dual Output DC/DC Converters
TOPPOWER

TPS1215A

2W 6KVDC Isolated Dual Output DC/DC Converters
TOPPOWER

TPS150

SWITCHING MODE 130W U CHANNEL POWER SUPPLIES
TOTAL-POWER