TPS120 SWITCHING MODE 120W U CHANNEL POWER SUPPLY
KEY FEATURES
*Universal input
*Built-in EMI filter
*Optional remote sense on main output
*Optional constant current charger
*Optional±12VDC/±24VDC/±48VDC input
*Optional cover
*Optional constant current change (for single output)
APPLICATIONS
*Telecommunications/Business machines
*Computer peripherals/Medical instruments
*Test & industrial equipments
ELECTRICAL SPECIFICATIONS
EMI & EMC
*FCC part 15, Class B
INPUT
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*Input range-----------90~264 VAC, universal
*Frequency------------47~63Hz
*CE, EN61000-3-2 (Class A) and –3 ; EN61000-4-2,
-3 , -4 , -5 , -6 and -11
*Inrush current--------38A typical ,Cold start @25℃,115VAC
*Efficiency------------65% ~85% typical at full load
*EMI filter------------FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
SAFETY APPROVAL
*Line regulation----- +/- 0.5% typical
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)
*TUV EN60950
OUTPUT
*Optional UL 2601 (EMI Class A)(COMPLY WITH)
*Maximum power----120W with 30 CFM forced air
*Hold-up time --------10ms typical at full load and 115 VAC
nominal line
ENVIRONMENTAL
*Overload protection-Short circuit protection
*Overvoltage
*Operating temperature :
0 to 50℃ambient; derate each output at 2.5% per
degree from 50℃to 70℃
*Humidity:
protection ------------Main output 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/-0.5 % per inquiry)
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
Power Derating Curve
120W
30 CFM Forced Air Cooling
90W
*Storage temperature:
-40 to 85℃
*Temperature coefficient:
+/- 0.05% per degree C
Output
Power
(Watts)
Natural
Convection
Cooling
60W
30W
0W
60W
45W
*MTBF demonstrated:
0
10
20 30 40 50 60 70
>100,000 hours at full load and 25℃ambient
conditions
°
Ambient Temperature( C)
TOTAL POWER INT. TEL: 877-646-0900 FAX: 978-453-7395
E-mail:sales@total-power.com http://www.total-power.com
-1-
TOTAL POWER
TPS120 SWITCHING MODE 120W U CHANNEL POWER SUPPLIES
OUTPUT
ADJUSTMENT MAXIMUM OUTPUT
PEAK OUTPUT
MINIMUM OUTPUT
TOTAL
RIPPLE & NOISE
PEAK OUTPUT
MODEL
VOLTAGE
RANGE CURRENT
CURRENT(NOTE1)
CURRENT
REGULATION(NOTE3)
%P-P(NOTE2)
POWER(NOTE1)
SINGLE OUTPUT MODEL SELECTION CHART
±10% Typical
±10% Typical
±10% Typical
±10% Typical
±10% Typical
±10% Typical
±10% Typical
±10% Typical
±10% Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
TPS120-10
TPS120-11
TPS120-12
TPS120-13
TPS120-14
TPS120-15
TPS120-16
TPS120-17
TPS120-18
+5V
+12V
+15V
+24V
+48V
+13.5V
+56V
+18V
+3.3V
24A
10A
8A
30A
12.5A
10A
0A
0A
0A
0A
0A
0A
0A
0A
0A
±3%
±3%
±3%
±3%
±3%
±3%
±3%
±3%
±5%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1.5%
5A
6.3A
3.1A
11.1A
2.8A
8.4A
37.5A
2.5A
8.9A
2.2A
6.7A
30A
DUAL OUTPUT MODEL SELECTION CHART
±10% Typical
+5 V
+12V
+5 V
12A
15A
6.2A
15A
3.1A
15A
15A
6.3A
6.3A
5A
1.2A
0.5A
1.2A
0.25A
1.2A
1.2A
0.5A
0.5A
0.4A
0.4A
2A
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1.5%
±1%
±1%
±1%
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
TPS120-20
TPS120-21
TPS120-22
TPS120-23
TPS120-24
TPS120-25
TPS120-26
Fixed
5A
±10% Typical
Fixed
12A
2.5A
12A
12A
5A
+24V
+5 V
±10% Typical
Fixed
- 5 V
±10% Typical
Fixed
+12V
- 12 V
+15 V
- 15 V
+3.3V
+12 V
+ 5 V
+48V
5A
±10% Typical
Fixed
4A
4A
5A
Fixed
20A
1A
25A
1.3A
5A
±10% Typical
±10% Typical
Fixed
0.1A
0.4A
0.2A
4A
2A
2.5A
TRIPLE OUTPUT MODEL SELECTION CHART
±10% Typical
+ 5V
+12V
- 5 V
+ 5V
+12V
-12V
+ 5V
+15V
-15V
+ 5V
+15V
-5 V
12A
4.5A
0.6A
12A
4.5A
0.6A
12A
3.5A
0.6A
15A
3A
15A
5.6A
0.8A
15A
1.2A
0.45A
0.06A
1.2A
±5%
±5%
±10%
±5%
±5%
±10%
±5%
±5%
±10%
±5%
±5%
±10%
±5%
±5%
±10%
±5%
±5%
±10%
±5%
±5%
±10%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Fixed
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
TPS120-30
TPS120-31
TPS120-32
TPS120-33
TPS120-34
TPS120-35
Fixed
±10% Typical
Fixed
5.6A
0.8A
15A
0.45A
0.06A
1.2A
Fixed
±10% Typical
Fixed
4.4A
0.8A
18.8A
3.8A
0.6A
17.5A
3.8A
0.8A
13.8A
3.1A
0.8A
13.8A
6.3A
1.3A
0.35A
0.06A
1.5A
Fixed
±10% Typical
Fixed
0.3A
Fixed
0.5A
14A
3A
0.05A
1.4A
±10% Typical
Fixed
+ 5V
+15V
-12V
+ 5 V
+24V
-12V
+ 5V
+12V
- 12V
0.3A
Fixed
0.6A
11A
2.5A
0.6A
11A
5A
0.06A
1.1A
±10% Typical
Fixed
150W Typical
150W Typical
150W Typical
150W Typical
0.25A
0.06A
1.1A
Fixed
±10% Typical
TPS120-36
TPS120-37
TPS120-38
Fixed
Fixed
0.5A
1A
0.1A
±10% Typical
+ 5V
+12V
+24V
11A
3.5A
1A
13.8A
4.4A
1.3A
1.1A
0.35A
0.1A
±5%
±5%
±1%
±1%
±1%
Fixed
Fixed
±10%
±10% Typical
+ 5V
+12V
+48V
8A
3A
1A
10A
3.8A
1.3A
0.8A
0.3A
0.1A
±5%
±5%
±1%
±1%
±1%
Fixed
Fixed
±10%
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395
E-mail:sales@total-power.com http://www.total-power.com
– 2 –
TOTAL POWER
TPS120 SWITCHING MODE 120W U CHANNEL POWER SUPPLIES
OUTPUT
ADJUSTMENT MAXIMUM OUTPUT
PEAK OUTPUT
MINIMUM OUTPUT
TOTAL
RIPPLE & NOISE
PEAK OUTPUT
MODEL
VOLTAGE
RANGE CURRENT
CURRENT(NOTE1)
CURRENT
REGULATION(NOTE3)
%P-P(NOTE2)
POWER(NOTE1)
QUAD OUTPUT MODEL SELECTION CHART
±10% Typical
+ 5V
+12V
-12V
-5V
12A
4.5A
0.5A
0.5A
12A
4A
15A
5.6A
0.6A
0.6A
15A
1.2A
0.45A
0.05A
0.05A
1.2A
0.4A
0.1A
0.1A
1.2A
0.3A
0.1A
0.1A
0.8A
0.35A
0.1A
0.2A
0.8A
0.2A
0.1A
0.1A
0.8A
0.2A
0.1A
0.2A
0.3A
0.1A
0.25A
0.2A
±5%
±5%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Fixed
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
150W Typical
TPS120-40
TPS120-41
TPS120-42
TPS120-43
TPS120-44
TPS120-45
TPS120-46
Fixed
±10%
±10%
±5%
Fixed
±10% Typical
Fixed
+ 5V
+12V
-12V
-5 V
5A
±5%
Fixed
1A
1.3A
1.3A
15A
±10%
±10%
±5%
Fixed
1A
±10% Typical
Fixed
+ 5V
+12V
-15V
+15V
+ 5V
+12V
- 12V
- 15V
+ 5V
+12V
- 12V
+48V
+ 5V
+12V
- 12V
+24V
+ 5V
+12V
- 12V
+36V
12A
3A
3.8A
1.3A
1.3A
10A
±5%
Fixed
1A
±10%
±10%
±5%
Fixed
1A
±10% Typical
Fixed
8A
3.5A
1A
4.4A
1.3A
2.5A
10A
±5%
Fixed
±10%
±10%
±5%
Fixed
2A
±10% Typical
Fixed
8A
2A
2.5A
1.3A
1.3A
10A
±5%
Fixed
1A
±10%
±10%
±5%
Fixed
1A
±10% Typical
Fixed
8A
2A
2.5A
1.3A
2.5A
3.8A
1.3A
3.1A
2.5A
±5%
Fixed
1A
±10%
±10%
±5%
Fixed
2A
±10% Typical
Fixed
3A
1A
±5%
Fixed
2.5A
2A
±10%
±10%
Fixed
NOTES:
1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal line, 0.1μF and 47μF Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover.
TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395
E-mail:sales@total-power.com http://www.total-power.com
-3-
TPS120-13 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
TPS120-14 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-15 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-16 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-17 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-18 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-20 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-21 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-22 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-23 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 | |
TPS120-24 | TOTAL-POWER | Telecommunications/Business machines | 获取价格 |
TPS120-13 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6