TP150DH48S15W [TOPPOWER]
100W~150W 1.5KVDC Isolated Wide Input Voltage DC/DC Converters;型号: | TP150DH48S15W |
厂家: | 南京拓品微 |
描述: | 100W~150W 1.5KVDC Isolated Wide Input Voltage DC/DC Converters |
文件: | 总3页 (文件大小:743K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TP100~150DH
100W~150W 1.5KVDC Isolated Wide Input Voltage DC/DC Converters
DESCRIPTION
:
The rated output power of TP100DH converters is 100W, TP150DH converters is 150W,the outline dimensions is
57.9*61*12.7mm,with 2:1,4:1 input voltage range ,the voltage range is 9V-18V, 9V-36V 18V-36V,18V-72V.The
accuracy of the converter can reach ±1%,it can be widely used in telecommunications, railway transportation,
instrument and etc.
FEATURES
100W output power
2:1,4:1 input voltage range
Input under voltage protection
Super capability with capacitive load
RoHs compliance
standard package
Fixed switching frequency
Long term short-circuit protection
Operating temperature: -40℃to 85℃
SELECTION GUIDE
Input Voltage
Output
Voltage
Capacity
Part Number
voltage VDC)
(
Current
(A)
Ability
)
(
VDC)
(uF)
Rated
12(2:1)
12(2:1)
12(2:1)
24(2:1)
24(2:1)
24(2:1)
24(2:1)
24(4:1)
24(4:1)
24(4:1)
24(4:1)
48(4
48(4
48(4:1)
4:1)
1)
1)
8(4:1)
48(4:1)
48(4:1)
48(4:1)
Range values
9-18
100
8
TP100DH12S05
TP100DH12S12
TP100DH12S15
TP100DH24S05
TP100DH24S12
TP100DH24S15
TP100DH24S24
TP100DH24S05W
TP100DH24S12W
TP100DH24S15W
TP100DH24S24W
TP100DH48S05W
TP100DH48S12W
TP100DH48S15W
TP100DH48S24
TP100DH48S4
T150DH48S05
TP0DH48S12W
TP15H48S15W
TP150DHS24W
TP150DH48S48W
5
20
8.3
6.6
2
2200
2200
9-18
12
15
5
84
87
9-18
10000
87
18-36
18-36
18-36
18-36
9-36
2200
200
1000
12
15
8.3
6.6
4.1
20
84
87
88
10000
87
2200
2200
1000
9-36
24
5
8.3
6.6
4.1
20
84
87
88
6
10000
87
18-72
172
18-72
18-72
18-72
18-72
18-72
18-72
18-72
18-72
2200
12
15
24
48
5
8.3
6.6
4.1
2.1
30
84
87
1000
88
88
470
10000
87
2200
2200
1000
470
12
15
24
48
812.5
10
87
85
85
85
6.2
3
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified
GENERAL CHARACTERISTICS
parameter
Test conditions
Input to output
Input to output
10~55Hz
Min
Typ
500
Max
Units
VDC
Ohm
G
Isolation voltage
Insulation resistance
Seismic
1500
100M
5
MTBF
MIL-HDBK-217F2
All input range
2x106
hrs
Burp, Automatic recovery
Over-current protection mode
www.gztoppower.com
TEL:0086-20-82019000
EMAIL:sales2@gztoppower.com
page 1 of 3
TP100~150DH
INPUT CHARACTERISTICS
parameter
Test conditions
Min
Typ
Max
Units
VDC
VDC
VDC
VDC
9
12
18
Voltage(2
Voltage(2
Voltage(4
Voltage(4
:
:
:
:
1)
1)
1)
1)
The12V input module
The24V input module
The24V input module
The48V input module
18
9
24
36
24
36
18
48
72
OUTPUT CHARACTERISTICS
parameter
Test conditions
Min
Typ
Max
Units
±1
%
Voltage accuracy
Io=0.1ꢀ1.0 x Ionom Vi=Vi rated
±0.2
±0.5
%
%
Line regulation
Load regulation
Vimin≤Vi≤Vimax
Io=0.1ꢀ1.0 x Ionom ,Vimin≤ Vi≤Vimax
Main Load and auxiliary load differ 25%,the auxiliary circuit of the
load with at least 25%, the main circuit with full load
±3
%
Auxiliary voltage accuracy
50
300
±5
mV
%
Ripple and noise
20MHz bandwidth
25% load changes
25% load changes
Vimin≤Vi≤Vimax
Transient recovery time
Transient overshoot time
Switch frequency
400
us
300
KHz
ENVIRONMENT CHARACTERISTICS
parameter
Test conditions
Min
Typ
Max
+95
+85
+125
100
Units
%
Storage Humidity
Non condensing
5
Operating Temperature
Storage Temperature
Max. Case Temperature
Power derating (above 71℃
-40
-55
-40
℃
℃
Operating Terve r
1.5mm from conds
℃
Lead Temperature
Cooling
300
℃
Free air convection
ꢀ
Module in every environment temp, case temature under shall not exceed the maximum case temperature level.
MECHANICAL DIMENSIONS
PIN CONNECTIONS
Units: mm
Pin
Single output
1
2
3
4
5
6
7
8
9
-Vin
CASE
CTL
+Vin
+Vo
+S
TRIM
-S
-Vo
www.gztoppower.com
TEL:0086-20-82019000
EMAIL:sales2@gztoppower.com
page 2 of 3
TP100~150DH
MODEL SELECTION
TP 100 D
H
24 S 05 W
4:1 input
Output voltage
S: Single output
D: Dual output
Input Rated Voltage
Package type
DC-DC
Output rated power
Brand name
USING ATTENTIONS
ꢀ
ꢀ
ꢀ
Module will cause irreversible damage when in the state of the input reverse polarity.
Module will cause irreversible damage when in the long-term overload conditions.
Module will cause irreversible damage when out of the maximum input voltage range.
STEMPERATURE DERATING GR
www.gztoppower.com
TEL:0086-20-82019000
EMAIL:sales2@gztoppower.com
page 3 of 3