5W 3KVAC Isolation Wide Input AC/DC Converters
TP05AL series is an economical open frame AC/DC switching power supply,The rated output power is 5W
with wide input voltage range, for both AC input and DC input application. High reliability, Low power
consumption, safety isolation .Widely used in industrial control and electrical instrumentation, smart home,etc.
FEATURES
Universal input voltage range
Both for AC and DC input voltage
Low Ripple &Noise
High efficiency, high power density, miniature
Low power consumption≤50mW
Overheat protection ,Over current protection
Operating temperature : -40
℃ to 70℃
International standard Footprint&Pinouts
Industrial product design
SELECTION GUIDE
Input Voltage
Voltage (VAC)
Range values
Output
Curren(t A)
Ripple &Noise
p-p
Efficiency (Typ. )
Part Number
%
Volta(g VDC)
.
0
50
50
50
50
50
)
Rated
67
74
76
78
82
TP05AL220S03W
TP05AL220S05W
TP05AL220S09W
TP05AL220S12W
TP05AL220S15W
TP05AL220S24W
220(4:1)
220(4:1)
220(4:1)
220(4:1)
220(4:1)
220(4:1)
85-305
85-305
85-305
85-305
85-305
85-305
3.3
5
1.00
1.00
0.55
0.42
0.33
0.21
9
12
15
24
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwspecified.
OUTPUT CHARACTERISTICS
Output Voltage accuracy (3.3Voutput)
Output Voltage accuracy (others)
Line regulation (3.3V output)
Line regulation (others)
±2.0%
±1.0%
±1.0%
±0.5%
Load regulation (3.3V output)
Load regulation (others)
±1.5%
%
Start rising time
Output hold time
(Typ.)
(Typ.)
s/230VAC
50ms/230VAC
INPUT CHARACTE
Input Voltage
8-305VAC
Nomial Input Volta
Input equency
100-240VAC
47 ~ 63Hz
Input Cnt ( Typ.)
Inrush currenTyp.)
120mA / 115VAC
60m A / 230VAC
Cold start 40A / 230 VAC
<1mA at 230VAC/50Hz
Leakage currenyp.)
PROTECTION CHARACTERISTICS
Over-current protection
Over-voltage protection
120--150% load, Automatic recovery after troubleshooting
yes
ENVIRONMENT CHARACTERISTICS
Operating temperature
Operating humidity
-40 ~ +70
℃ (According to the output load derating curve)
85% .RH max
Storage temperature
–40 ~ +85, 10 ~ 95% RH
Temperature coefficient
Vibration coefficient
0.03%/ (0~ 50℃ )
10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes
Natural cooling
Cooling method
www.gztoppower.com
TEL:0086-20-82019000
Email:sales2@gztoppower.com
Page 1 / 3
TP05AL Series
SAFETY & ELECTROMAGNETIC COMPATIBILITY
UL60950,EN60950
Safety Standard
CLASS II
Safety Level
I/P-O/P:3KVAC
Isolation voltage
I/P-O/P,:>100M Ohms/500VDC 25℃ 70% RH
Isolation resistance
Conduction and Radiation
Electrostatic Discharge
RF radiation immunity
Electrical Fast Transient Burst
Surge
EN55011, EN55022 (CISPR22) class B (Typical application circuit diagram 1)
IEC/EN 61000-4-2 level 4 8kV/15kV (Typical application circuit diagram 1)
IEC/EN 61000-4-3 level 4 (Typical application circuit diagram 1)
IEC/EN 61000-4-4 level 4 4kV (Typical application circuit diagram 1)
IEC/EN 61000-4-5 level 4 2kV (Typical application circuit diagram 1)
EN61000-3-2 (Typical application circuit diagram 1)
Harmonic Current
OTHERS
MTBF
≥300K hrs min.
MIL-HDBK-217F(25)
Dimensions
Weight
37*18.5*12mm (L*W*H)
10g
packaging
360*300*250mm
NOTES
1.This model is open Frame, in order to meet the safety requirements of the module primary anecondary exerncomponents between the need to maintain a safe
distance of at least 6.4mm.
2.The data in this manual are measured at TA=25 ° C, humidity <75%, input no(115Vac and 2c) and output rated load,except for special
instructions.
3.In order to improve the efficiency of light load conversion, when the moduld load, the module may have weak audio noise, but does not affect
the product performance and reliability.
4. After the module is assembled, it needs to be Dispensin
PRODUCT CHARACTERISTICS CURVE
TYPICAL APLICATION CIRCUIT
diagram 1
Notes:
1.C2 is a ceramic capacitor to filter out high frequency noise.C3 is High-frequency low-resistance electrolytic capacitor ,TVS tube in the
module exception protection after the circuit, it is recommended to use.
2. In the general application, Its not mandatory to use the common-mode inductance within the dashed box;
You can use this common-mode inductance (L=30mH) to meet the higher EMC requirements.
3. For technical support, please contact our engineers.
www.gztoppower.com
TEL:0086-20-82019000
Email:sales2@gztoppower.com
Page 2 / 3
TP05AL Series
APPLICATION CIRCUIT TYPICAL VALUES
PN
R
MOV
L
C1
C2
CX
CY
C3
TVS tubes
TP05AL220S03W
TP05AL220S05W
TP05AL220S09W
TP05AL220S12W
TP05AL220S15W
TP05AL220S24W
330uF/16V
330uF/16V
330uF/16V
220uF/16V
150uF/25V
150uF/35V
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ30A
SMBJ30A
10
Ω/2W
10D561K
2mH
10
μF/450V
104K/50V
104K/275Vac
1nF/400Vac
MECHANICAL DIMENSIONS
PIN
1
3
AC
AC
5
+V(cap)
-V(cap)
-V
7
12
14
+Vo
All dimens in mm ±0.2~±0.5mm
MODEL SELECTIO
TP 05
A
L
W:4:1 Wide voltage input range
Main (auxiliary) output voltage
S:single output, D:Dual output
Rated input voltage
Package type
AC-DC
Rated output power
Brand name
www.gztoppower.com
TEL:0086-20-82019000